(EN)Ductless brochure 2022-04-27-web.pdf

Page 1

Clean Air, Pure LivingDuctless Mini Split Systems

Page 2

Comfort & QualityFrosting Defrosting55 Drying Clean CompleteThe evaporator will collect enough condensation to generate water capable of washing away accumulated dirt. Quick drying will remove residue, resulting in a cleaner and more sterile unit.Self-CleaningAuto Restart* OptionalWhen power is restored, the unit automatically runs according toSUHYLRXVVHWWLQJVE\YLUWXHRIÁDVKPHPRU\3D AirflowVertical and horizontal louvers driven by stepping motors help achieve a wider air supply angle and longer distance to maximize comfort. Ionizer & Plasma*A built-in generator of ionizer and plasma can help remove dust, eliminate odors and smoke, sterilize and greatly improve air quality. Aesthetically engineeredarc curves are integrated in the panel design to provide a silky smooth appearance.Exquisite DesignPearl White BodyA pearl-white body with a thin and graceful appearance easily blends in with any home decor. Elegant Display PanelThe softly lit LED panel displays air quality and temperatures with clarity and without unwanted glare.

Page 3

.Alarm outputIn the event of a failure, the unit can output an alarm signal to the designated receiving end..Wired control*:LUHGFRQWUROZLWKDLUÀOWHUUHPLQGHUDYDLODEOH"JSmMUFSDMFBOJOHSFNJOEFSGVODUJPO0OPGGUFNQGBOTQFFENPEFTFUUJOHUJNFSBOEDIFDLGVODUJPO#MBDLCBDLHSPVOEBOEXIJUFMJHIU6MUSBUIJOCPEZBOETUZMJTIEFTJHO5HPRWHO\FRQWUROWKHKHDWSXPSZLWKDEXLOWLQZLÀPRGXOH6HWDWLPHUDQGFRQWUROWHPSHUDWXUHVZLWKHDVHZKLOHDZD\IURPKRPHWKURXJKDPRELOHSKRQH:LÀFRQWURO:LÀ&RQWURO:LÀ0RGXOH0LQL6SOLW6HOIGLDJQRVLV,QFDVHRIIDLOXUHDQHUURUFRGHZLOOEHGLVSOD\HGDQGRSHUDWLRQSDUDPHWHUVFDQEHUHWULHYHGIURPWKHSDQHOthrough the remote controller.Failure* Optional

Page 4

Self diagnosisIf the failure happens, the error code will be displayed on the panel, you can also check the status by remote controller.Smart air supplyIn cooling mode, the angle of the louver is fixed upward, and in heating mode, the angle of the louver is fixed downward.Turbo modeRuns at maximum air volume within a period of time to quickly reach the set temperature.Fireproof E-boxThe E-box is made of high fireproof level material, to fully meet the safety regulations for safe operation.Child lockButton lock function prevents children from accidentally pressing the remote controller.Self-cleaningWhen self clean function is activated, the indoor coil dries itself using a 3-stage cycle that minimises the accumulated dust and mould. Do not disturbOne button to turns off the indoor unit beep and LED display, and the LED light panel is only displayed for 10 seconds each time in the do not disturb mode.DONOTDISTURBRefrigerant leakage detectionDetection of continuous decrease of T2 temperature within a certain period of time is identified in cooling mode.Error alarm outputIn the event of a falure, the system will send a message to a designated terminal receiving equipment.Emergency buttonIf a temperature sensor error occurs the unit will alarm and operate in emergency function mode until replaced.Sleep modeLowest wind, for cooling, temperature increases by 1 degree per hour for 2 hours. For heating, decreases by 1 degree per hour for 2 hours. Vertical swingThe outer louver swings vertically to adjust the air supply angle in the vertical direction.Low voltage operation172V low voltage operation.+HDWLQJDWʝStable running heating mode in -15 degrees low ambient temperature.ʝSlience modeThe AC fan is adjusted to the lowest wind to reduce the indoor noise to 20dB(A).Louver position memoryThe indoor unit will remember the louver position at the time it was turned off. It will set the louver to the same position again when it is initialised. Room card functionSpecialised built in reserved room cards ports, which allows a remote ON/OFF switch to be easily connected. Dual drainageTwo drainage holes are reserved to install drainage a pipe left or right according to different project requirements.Auto modeThe air conditioner will auto run different modes according to the difference between the room temperature and the set temperature.24H timerThe system can be preset to automatically start and stop within 24-hour period.24hAuto restartIf the system stops because of power failure, it will auto restart in the previous settings and mode when the power recovers. &RRLQJDWʝWith built-in low ambient kit and a specially designed PCB, the outdoor fan speed is automatically changed according to the condensing temperature.ECO modeBy pressing this button the system will run into power saving mode to save money.Anti-cold windThis limits the fan from blowing colder air when in heating mode thus preventing cold drafts.ʝKHDWRSHUDWLRQWhen the room temperature is lower WKDQʝWKHDLUFRQGLWLRQHUautomatically starts to maintain the URRPWHPSHUDWXUHDERYHʝCelsius & Fahrenheit switchConvert Fahrenheit and Celsius temperature display to each other via wireless controller.°F ʝFunctionsStandard

Page 5

WIFI controlRemote WIFI control enables programming at a distance from your portable device.1W standbyTurn off the power of ODU after 2 minutes in the shutdown state, and disconnect the power of ODU at air supply mode for 2 minutes for power saving.The controller board of the indoor unit reserves a port to be used by wired controller.Wired controllerFilter cleaning reminderThe optional wired controller equiped with filter cleaning reminder function, will count the total running time, and send a reminder the time is reached.Special filterThe Vitamin C/Silver Ion /cold catalyst 3-in-1 special filter improves the air quality.Golden fin of indoor and outdoor units are customizable for better appearance and anti-corrosion performance.Golden finBuilt-in generator produces electrically conducted plasma to sterilize and remove dust, and purify the air to benefit your health.PlasmaBuilt-in generator produces ionization to sterilize and remove dust, and purify the air to benefit your health.IonizerThe outdoor chassis is heated to prevent the running fan blade from damage due to accumulated snow.Basepan heaterOptional

Page 6

SpecificationsStandardSee our ducted units at https://www.zenairtec.com/Nominal CapacityModel V/N/HzBtu/hBtu/hBtu/hW/WCFMCFMdB(A)mminchmminchkglbsmminchmminchkglbsmminchft(m)ft(m)ʞʞCoolingHeating2XWGRRUDLUÁRZ,QGRRUDLUÁRZ2XWGRRUQRLVHSRZHUOHYHOOutdoorunitIndoorunitRefrigerantPipingAmbient temp.EERSEERCapacity @ 47CapacityCapacity @ 17COP @ 47HSPF4Dimension(WxHxD)Packing(WxHxD)1HW*URVVZHLJKWDimension(WxHxD)Packing(WxHxD)Max.pipe lengthMax.high dropCoolingHeatingLiquid/Gas side%WXZ%WXZ1HW*URVVZHLJKWZEN-WM09HP19S9K1088900011.20199500.3.3010.430051735x475x25028.94x18.7x9.84850x550x35033.46x21.65x13.7824/2652.9/57.3715x295x19828.15x11.61x7.8800x380x29031.5x14.96x11.428.5/10.518.7/23.2ĭĭ1/4” / 3/8”82 (25)58-122208-230V/1Ph/60Hz33 (10)0~86ZEN-WM12HP19S12K11.41150010.52011800.3.5117638053735x475x25028.94x18.7x9.84850x550x35033.46x21.65x13.7824/2652.9/57.3864x300x20034.02x11.87x7.81950x380x29037.4x14.96x11.429.5/11.520.9/25.41/4” / 3/8”82 (25)208-230V/1Ph/60Hzĭĭ58-12233 (10)0~86ZEN-WM18HP19S18K17800111918000.3.310.5165353055790x520x28031.10x20.47x11.02920x600x38036.22x23.62x14.9632/3570.6/77.2972x320x21538.27x12.6x8.461070x410x31042.13x16.14x12.211.5/14.525.4/321/4” / 1/2”98.5 (30)208-230V/1Ph/60Hzĭĭ0~8666 (20)58-122ZEN-WM24HP19S24K230001017.524000.3.159.5185368057848x670x34533.39x26.38x13.58975x770x43538.39x30.31x17.1341/4590.4/99.21080x226x33542.52x13.19x8.9975x770x43538.39x30.31x17.1341/4590.4/99.21/4” / 1/2”98.5 (30)208-230V/1Ph/60Hz58-12266 (20)0~86ĭĭ

Page 7

Nominal CapacityModel V/N/HzBtu/hBtu/hBtu/hW/WCFMCFMdB(A)mminchmminchkglbsmminchmminchkglbsmminchft(m)ft(m)ʞʞCoolingHeating2XWGRRUDLUÁRZ,QGRRUDLUÁRZ2XWGRRUQRLVHSRZHUOHYHOOutdoorunitIndoorunitRefrigerantPipingAmbient temp.EERSEERCapacity @ 47CapacityCapacity @ 17COP @ 47HSPF4Dimension(WxDxH)Packing(WxDxH)1HW*URVVZHLJKWDimension(WxDxH)Packing(WxDxH)Max.pipe lengthMax.high dropCoolingHeatingLiquid/Gas side%WXZ%WXZ1HW*URVVZHLJKWCFMHeat +(up to -30°C) See our ducted units at https://www.zenairtec.com/12.59000 (3700~13300)15.825.512000 (5100~14300)120003.901323.50291.18/194.12/152.9454.5805x330x55431.69x12.99x21.81915x370x61536.02x14.57x24.2133.6/36.474.07/80.25802x200x29531.57x7.87x11.61 875x285x38034.45x11.22x14.968.5/1119 /24.251/4” / 3/8”82 (25)32 (10)-22~122-22~86208/230V/1Ph/60Hzĭĭ9KZEN-WM09HP23S12000 (3700~13300)132212000 (5100~14300)120003.6012.71323.50291.18/194.12/152.9456805x330x55431.69x12.99x21.81915x370x61536.02x14.57x24.2133.6/36.474.07 / 80.25802x200x29531.57x7.87x11.61875x285x38034.45x11.22x14.968.5/1119 /24.251/4” / 1/2”82 (25)32 (10)-22~122-22~86208/230V/1Ph/60Hzĭĭ12KZEN-WM12HP23S18000 (8400~20200)1321.518000 (12000~23000)190003.35111764.70530.59/458.82/382.3559890x342x67335.04x13.46x26.50995x398x74039.17x15.67x29.1345.8/49100.97/108.031083x244x33642.64x9.61x13.231155x415x31545.47x16.34x12.4013.4/1729.54/37.481/4” / 1/2”98 (30)66 (20)-22~86208/230V/1Ph/60Hzĭĭ-22~122 -22~12218KZEN-WM18HP23S23000 (4650~26600)12.521.526000 (9550~27000)23000311.52235.30601.18/458.82/382.3562946x410x81037.24x16.14x31.891090x500x88542.91x19.69x34.8461/65.5134.48/144.401082x234x33742.60x9.21x13.271155x415x31545.47x16.34x12.4013.6/17.329.98/38.143/8” / 5/8”164 (50)82 (25)-22~86208/230V/1Ph/60Hzĭĭ24KZEN-WM24HP23S

Page 8

info@zenairtec.com // www.zenairtec.comDistributed By: