Return to flip book view

Trulite CG501 Impact Storefront

Page 1

CG501 I M P A C T STOREFRONT 2 1 2 x 5 FLORIDA and TEXAS TDI APPROVAL AVAILABLE WET DRY GLAZED OPTION AVAILABLE TRULITE ARCHITECTURAL PRODUCTS On Time On Spec On Cost 403 Westpark Court Suite 201 Peachtree City GA 30269

Page 2

CG501 FRAMING 2 1 2 x 5 10 10A E2B ELEV 501 20 11 11A 21 21A 12 31 40 40A 30 CG501 IMPACT STOREFRONT WALL CG501 IMPACT STOREFRONT WALL GENERAL NOTE THIS PRODUCT RECEIVED A FLORIDA BUILDING APPROVAL PLEASE REFER TO PRODUCT APPROVAL DRAWINGS FOR FURTHER INFORMATION ABOUT THE EXTENT OF USE AND ITS LIMITATION DETAIL SHOWN IS WET GLAZED OPTION IN CG500 STOREFRONT WALL FOR DRY GLAZED OPTION REFER TO PAGE E2B 11 AND E2B 12 FOR DETAIL APPLICATION PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH FLORIDA HURRICANE BUILDING CODE 8TH EDITION 2023 INCLUDING HIGH VELOCITY ZONES DESIGN PRESSURE VARIES AT 70 80 PSF FOR LIGHT MULLION W REINF LONG SPAN 65 65 PSF FOR LIGHT MULLION W O REINF SHORT SPAN 60 60 PSF FOR HEAVY MULLION W O REINF LONG SPAN 70 70 PSF DOOR FRAMES W TRANSOM W OR W O SIDELITE 70 70 PSF DOOR FRAMES W O TRANSOM W OR W O SIDELITE TYPICAL GLASS BITE 9 16 UNLESS OTHERWISE NOTED GLASS SIZE FORMULA DLO 1 1 8 CG501 SYSTEM HIGHLIGHT 2 1 2 x 5 CENTER GLAZED SYSTEM SCREW SPLINE ASSEMBLY INTERIOR OR EXTERIOR GLASS SET OPTIONAL STEEL REINFORCEMENT FBC APPROVED PRODUCT TAG DESCRIPTION 10 STANDARD HEADER DETAIL 10A ALTERNATE HEAD 11 STANDARD INTERMEDIATE HORIZONTAL 11A ALTERNATE INTERMEDIATE HORIZONTAL 12 STANDARD SILL DETAIL 20 STANDARD JAMB DETAIL 21 INTERMEDIATE LIGHT MULLION 21A INTERMEDIATE HEAVY MULLION 30 DOOR JAMB WITH SIDELITE 31 TRAMSOM WITH SIDELITE 32 TRANSOM JAMB DETAIL 40 DOOR HEADER TRANSOM DETAIL TRULITE GLASS ALUMINUM SOLUTIONS www trulite com 800 432 8132

Page 3

CG501 FRAMING 2 1 2 x 5 E2 ISOMETRIC CG501 4 CG501 7 CG501 2 CG501 3 CG501 6 CG501 3 CG501 5 CG501 IMPACT STOREFRONT SYSTEM TRULITE GLASS ALUMINUM SOLUTIONS www trulite com 800 432 8132 CG501 2 CG500 12 CG501 3

Page 4

CG501 2 1 2 x 5 VARIES 2 1 2 E2B 01 CG501 11 RG 8 VAR 2 17 32 RG 2 D C 995 SILICONE 5 10 TYPICAL HEAD RG 2 CG501 2 RG 8 CG501 3 D C 995 SILICONE 5 1 32 10A ALTERNATE HEAD TRULITE GLASS ALUMINUM SOLUTIONS www trulite com 800 432 8132

Page 5

CG501 IMPACT STOREFRONT FRAMING 2 1 2 x 5 CG501 3 RG 8 2 1 2 RSB 13 WD 451 E2B 02 CG501 6 2 1 2 RG 2 D C 995 SILICONE 11 INTERMEDIATE HORIZONTAL 5 RG 2 D C 995 SILICONE RSB 14 WD 451 RG 8 CG501 3 11A ALT INTERMEDIATE HORIZONTAL TRULITE GLASS ALUMINUM SOLUTIONS www trulite com 800 432 8132 CG501 6

Page 6

CG501 IMPACT STOREFRONT FRAMING 2 1 2 x 5 E2B 03 2 1 2 1 8 VAR RG 2 CG501 3 5 D C 995 SILICONE RG 8 RSB 13 RSC501 12 TYPICAL SILL CG501 2 SEALANT CG500 12 TRULITE GLASS ALUMINUM SOLUTIONS www trulite com 800 432 8132

Page 7

CG501 IMPACT STOREFRONT FRAMING 2 1 2 x 5 E2B 04 RG 8 D C 995 SILICONE 5 RG 2 VARIES CG501 11 2 1 2 20 TYPICAL JAMB TRULITE GLASS ALUMINUM SOLUTIONS www trulite com 800 432 8132

Page 8

CG501 IMPACT STOREFRONT FRAMING 2 1 2 x 5 ST500 4 OPTIONAL E2B 05 FAS25 1 RG 8 D C 995 SILICONE 5 RG 2 CG501 5 2 1 2 CG501 4 21 INTERMEDIATE MULLION TRULITE GLASS ALUMINUM SOLUTIONS www trulite com 800 432 8132

Page 9

CG501 IMPACT STOREFRONT FRAMING 2 1 2 x 5 DF500 3 OPTIONAL E2B 06 RG 8 D C 995 SILICONE 5 RG 2 CG501 5 CG501 7 2 1 2 21A HEAVY DUTY MULLION TRULITE GLASS ALUMINUM SOLUTIONS www trulite com 800 432 8132

Page 10

CG501 IMPACT STOREFRONT FRAMING 2 1 2 x 5 E2B 07 ST500 1 OPTIONAL 10029 RG 5 RG 8 D C 995 SILICONE 5 RG 2 CG501 5 DF500 1 2 1 2 30 DOOR JAMB DETAIL TRULITE GLASS ALUMINUM SOLUTIONS www trulite com 800 432 8132

Page 11

CG501 IMPACT STOREFRONT FRAMING 2 1 2 x 5 E2B 08 ST500 1 OPTIONAL DF117 DF107 FAS10 1 RG 8 D C 995 SILICONE 5 RG 2 CG501 5 DF500 1 2 1 2 31 TRANSOM DETAIL TRULITE GLASS ALUMINUM SOLUTIONS www trulite com 800 432 8132

Page 12

CG501 IMPACT STOREFRONT FRAMING 2 1 2 x 5 E2B 09 ST500 1 OPTIONAL DF117 RG 2 DF107 DF500 1 SHIM AS REQUIRED FAS10 1 STRUCTURAL PERIMETER ANCHOR SW700 18 FAS14 2 DC 795 2 1 2 32 TRANSOM JAMB DETAIL VARIES TRULITE GLASS ALUMINUM SOLUTIONS www trulite com 800 432 8132

Page 13

CG501 IMPACT STOREFRONT FRAMING 2 1 2 x 5 E2B 10 5 RG 2 DF107 2 1 2 D C 995 SILICONE DF117 RG 8 RSB 18 DF500 2 10029 44013 OPTIONAL FBC APPROVED RESISTOR IMPACT DOOR 40 DOOR TRANSOM DETAIL TRULITE GLASS ALUMINUM SOLUTIONS www trulite com 800 432 8132

Page 14

CG501 IMPACT STOREFRONT FRAMING 2 1 2 x 5 5 E2B 11 2 1 2 1 2 4 1 2 L 1 1 2 x 1 1 2 x 1 8 CONT ALUM ANGLE 1 8 THK ALUM BREAK METAL 10 x 1 2 PPMS SPACED 18 O C L 1 x 3 4 x 1 8 CONT ALUM ANGLE SILICONE SEALANT WITH BACKER ROD 4 1 2 1 2 RG 8 D C 995 SILICONE 5 RG 2 CG501 5 CG501 7 2 1 2 22 90 DEGREE CORNER TRULITE GLASS ALUMINUM SOLUTIONS www trulite com 800 432 8132

Page 15

CG501 IMPACT STOREFRONT FRAMING 2 1 2 x 5 E2B 12 VAR 2 1 2 CG501 11 CG501 3 2 1 2 CG501 6 RG 13 RSB 13 WD 451 RG 2 RG 13 5 10 TYPICAL HEAD RG 2 RG 13 5 11 INTERMEDIATE HORIZONTAL CG501 3 RG 2 2 1 2 1 8 VAR 5 RG 13 CG501 2 SEALANT RSB 13 SC501 CG500 12 12 TYPICAL SILL DRY GLAZED SETUP ALTERNATE OPTION 1 5 16 OVER ALL THICKNESS INSULATED GLASS 1 4 TEMPERED GLASS 1 2 AIR SPACE 1 4 H S 0 090 SGP INTERLAYER 1 4 H S TRULITE GLASS ALUMINUM SOLUTIONS www trulite com 800 432 8132

Page 16

CG501 IMPACT STOREFRONT FRAMING 2 1 2 x 5 E2B 13 RG 13 ST500 4 OPTIONAL RG 13 5 RG 2 FAS25 1 5 RG 2 CG501 5 VAR 2 1 2 CG500 11 20 TYPICAL JAMB ST500 1 OPTIONAL 2 1 2 CG500 4 21 INTERMEDIATE MULLION DF117 FAS10 1 RG 13 5 RG 2 CG501 5 DF107 DF500 1 2 1 2 31 TRANSOM DETAIL DRY GLAZED SETUP ALTERNATE OPTION 1 5 16 OVER ALL THICKNESS INSULATED GLASS 1 4 TEMPERED GLASS 1 2 AIR SPACE 1 4 H S 0 090 SGP INTERLAYER 1 4 H S TRULITE GLASS ALUMINUM SOLUTIONS www trulite com 800 432 8132

Page 17

CG501 FRAMING 2 1 2 x 5 E2B BOM CG501 PARTS TABLE CG501 2 SILL HEAD CG501 7 HEAVY DUTY MULLION CG501 3 GLASS STOP CG501 11 WALL JAMB HEAD DEEP POCKET CG501 4 VERTICAL MULLION CG501 5 VERTICAL POCKET FILLER CG501 6 INTERMEDIATE HORIZONTAL DF107 TRANSOM GLASS STOP DF117 TRANSOM SASH DF500 2 TRANSOM BAR DF500 1 HINGE JAMB RG 2 EXTERIOR GLAZING GASKET RG 8 INTERIOR SPACER GASKET RG 5 DOOR STOP BULB GASKET RG 13 INTERIOR GASKET DRY GLAZED TRULITE GLASS ALUMINUM SOLUTIONS www trulite com 800 432 8132

Page 18

CG501 IMPACT STOREFRONT FRAMING 2 1 2 x 5 2 1 2 E2B S1 5 CG501 4 CG501 5 CG501 STOREFRONT CG501 4 CG501 5 COMBINED Area Sq In 1 9785 Perimeter In 45 2680 Wt Ft Lbs 2 2753 Ix In4 5 7166 Sx In3 2 2573 Rx In 1 6998 Iy In4 1 5394 Sy In3 1 1931 Ry In 0 8821 MULLION CAPACITY TABLE UNREINFORCED Mullion Spacing 8 0 8 6 9 0 MULLION HEIGHT 9 6 10 0 10 6 11 0 11 6 12 0 13 0 14 0 3 0 3 6 4 0 4 6 5 0 5 6 6 0 6 6 7 0 113 42 97 22 85 06 75 61 68 05 61 86 56 71 52 35 48 61 94 56 81 05 70 92 63 04 56 73 51 58 47 28 43 64 40 52 79 66 68 28 59 74 53 10 47 80 43 45 39 83 36 76 34 14 67 73 58 05 50 80 45 15 40 64 36 95 33 86 31 26 29 02 58 07 49 77 43 55 38 72 34 84 31 67 29 03 26 80 24 88 50 16 43 00 37 62 33 44 30 10 27 36 25 08 23 15 21 50 43 63 37 39 32 72 29 08 26 17 23 80 21 81 20 13 18 69 38 18 32 72 28 63 25 45 22 91 20 82 19 09 17 62 16 36 33 60 28 80 25 20 22 40 20 16 18 33 16 80 15 51 14 40 26 43 22 65 19 82 17 62 15 85 14 41 13 21 12 20 11 32 20 94 17 95 15 70 13 96 12 56 11 42 10 47 9 66 8 97 Note Values are in PSF Allowable wind load stresses for aluminum alloy 6063 T6 25 ksi 1 65 15 15 ksi and A36 steel 36 ksi x 0 67 24 ksi were used Deflection limit is L 175 For spans over 13 6 deflection limit of L 240 1 4 applies TRULITE GLASS ALUMINUM SOLUTIONS www trulite com 800 432 8132

Page 19

CG501 IMPACT STOREFRONT FRAMING 2 1 2 x 5 2 1 2 E2B S2 5 CG501 7 CG501 5 CG501 HEAVY MULLION CG501 7 CG501 5 COMBINED Area Sq In 2 8111 Perimeter In 44 7364 Wt Ft Lbs 3 2328 Ix In4 9 7406 Sx In3 3 8721 Rx In 1 8615 Iy In4 1 9446 Sy In3 1 5319 Ry In 0 8317 HEAVY MULLION CAPACITY TABLE UNREINFORCED Mullion Spacing 8 0 8 6 9 0 MULLION HEIGHT 9 6 10 0 10 6 11 0 11 6 12 0 13 0 14 0 3 0 3 6 4 0 4 6 5 0 5 6 6 0 6 6 7 0 193 26 165 65 144 95 128 84 115 96 105 41 96 63 89 20 82 82 161 12 138 10 120 84 107 41 96 67 87 88 80 56 74 36 69 05 135 73 116 35 101 80 90 49 81 44 74 03 67 86 62 64 57 17 115 41 98 92 86 60 76 94 69 24 62 95 57 70 53 26 49 46 98 95 84 81 74 21 65 97 59 37 53 97 49 47 45 67 42 40 84 47 73 26 64 10 56 98 51 28 46 62 42 74 39 45 36 63 74 34 63 72 55 75 49 56 44 60 40 55 37 17 34 31 31 86 65 06 55 77 48 79 43 37 39 03 35 48 32 53 30 02 27 88 57 26 49 08 42 95 38 17 34 35 31 23 28 63 26 43 24 54 45 03 38 60 33 78 30 02 27 02 24 56 22 52 20 78 19 30 35 68 30 58 26 76 23 79 21 41 19 46 17 84 16 47 15 29 Note Values are in PSF Allowable wind load stresses for aluminum alloy 6063 T6 25 ksi 1 65 15 15 ksi and A36 steel 36 ksi x 0 67 24 ksi were used Deflection limit is L 175 For spans over 13 6 deflection limit of L 240 1 4 applies TRULITE GLASS ALUMINUM SOLUTIONS www trulite com 800 432 8132