Schneider ElectricPanel Builders CatalogPowerLogic™series energy and power meters catalog for Panel Builders03/23
Introduction 3Selection guide panorama 4Current transformers 8Panel instruments DIN ammeter/voltmeter25Basic energy metering iEM2000, iEM3000, PM3000, and PowerTag Energy series36Wireless products PowerTag Control and HeatTag96Basic multi-function metering PM5000 and PM5350 series104EcoStruxure™ Panel Server Entry, Universal and Advanced 125Commercial reference numbers 136See your Viking Electric representative for complete ordering information.Schneider Electric PowerLogic™ Energy and power meters catalog for panel builders Contentswww.se.comPANEL BUILDERS CATALOG TABLE OF CONTENTSVersion: 1.0 - 30/05/2022PLSED310126EN_01a2
Why Panel Builders Choose Schneider Electric?Schneider Electric is the global specialist in energy management and as such it has the most complete power motoring product line, going from simple indicators (analog meters) and CTs, to world class accurate energy meters and powerful compact power meters. These proven products come with multiple options to satisfy any requirement.Schneider Electric products are safe and reliable. We comply with the most stringent standards, including IEC, MID, UL, etc., and we thoroughly test all products with third-party laboratories. This gives our partners the peace of mind and the confidence that they are maintaining a good reputation while delivering the best value in equipment and service to their customers.Our products are simple to install, configure, and use. This saves our partners time and money and lets them deliver the best solutions in a timely and cost-effective manner.Whatever the size or type of application, the PowerLogic™ product line is an integral part of smart panels.PANEL BUILDERS CATALOG INTRODUCTION3Version: 1.0 - 30/05/2022PLSED310126EN_01aVersion: 1.0 - 30/05/2022PLSED310126EN_01a
Current transformersPanel instrumentsCTsIp / 5 AName iAMP iVLT AMP/VLT iFRE iCH/iCIcurrent transformerFunctionammeter, voltmeterammeter, voltmeterammeter, voltmeterfrequency meter hour counterpulse counterInstallationi. Solid Core CTsb Insulated Cable, diameter 21 to 35 mm b busbar through transformerb cable connectionsii. Split Core CTsb� CT installation without the need to uninstall and reinstall power conductors b Cable and Busbar connectionsApplicationsPanel instrumentationPanel instrumentation I / U I / U I / U F hours/pulsesEnergy efficiency & costSub-billing & cost allocation Demand & load managementBilling analysisPower availability & reliabilityCompliance monitoringSag/swell, transientHarmonicsRevenue meteringRevenue meterCharacteristics Characteristicsi. Solid Core CTsb transformation ratio : 40/5 A to 6000/5 Ab accuracy : class 0.5 to 3b maximum rated operational voltage : 720 V ACb tropicalised range 25 °C to +60 °C (1) relative humidity > 95 %(1) Warning: some products are limited to +50 °C.ii. Split Core CTsb transformation ratio : 100/5A to 4000/5Ab accuracy : class 0.5 to 3b maximum rated operational voltage : 720 V ACb Cable connection : -5°C to +50°Crelative humidity 5–85 %b Busbar connection : 5°C to +40°Crelative humidity 5–85 %Measurement accuracy Class 1.5 ± 0.5 % ± 1 digit Class 1.5 ± 0.5 % ± 1 digitInstallation DIN rail4 x 18 mm modules DIN rail2 x 18 mm modules flush mounted72 x 72 mm 96 x 96 mmDIN rail2 x 18 mm modules iCI, iCH: DIN rail2 x 18 mm modules CH: flush mountMeasurement iAMP: 30 A director external CTiVLT:600 V AC direct or external VTVLT: 500 V AC direct or external VTAMP: external CT400 V AC direct Communication portsInputs / OutputsMemory capacitypage 8page 26 page 27 page 28 page 27 page 32Panorama of the PowerLogic™ range Use this panorama to select the most efficient products for your application needsPOWERLOGIC™ CATALOG PANORAMAVersion: 1.0 - 30/05/2022PLSED310126EN_01b4
Panorama of the PowerLogic™ range (cont'd) Basic energy meteringName iEM2xxx RangeiEM2000, iEM2100, iEM2400iEM3000 Series PM3000 Series PowerTag Energy SeriesFunctionkilowatt-hour meter kilowatt-hour meterspower and energy metersmetering & sub-meteringClass 0.5S IEC 62053-22Class 1 IEC 62053-21Class 2 IEC 62053-23wireless power & energy meterApplicationsPanel instrumentationPanel instrumentation E (in all range)I, U, F, P, Q ,S, PF (in selected ranges)I, U, F, P, Q, S, PF, E(Power demand andcurrent demand)I, U, F, P, Q, S, PF, E(Power demand andcurrent demand)I, U, F, P, Q, S, PF, E (Depending on reference; Power demand depending on gateway)Energy efficiency and costSub-billing & cost allocation cost allocation onlyDemand & load managementBilling analysisPower availability & reliabilityCompliance monitoringDip/swell, transientHarmonicsRevenue meteringRevenue meterCharacteristicsMeasurement accuracy Class 1 (Wh)/ Class 2 (VARh) Class 0.5S / Class 1 (Wh)Class 2 (VARh)Class 0.5 IEC 61557-12 PMD/DDClass 1 (active energy)Installation DIN rail1, 2 x 18 mm modulesDIN rail5, 7 x 18 mm modulesDIN rail on product or on cables depending on the referenceVoltage measurement upto 276 V (Ph-N) AC direct 100 - 277 V L-N,173 - 480 V L-Lup to 1MV AC (ext VT)50 V to 330 V AC (Ph-N) 80 V to 570 V AC (Ph-Ph)up to 1M V AC (ext VT)up to 277 V AC (Ph-N) / 480 V AC (Ph-Ph) depending on the referenceCurrent measurement 40 to 125 A direct external CT (iEM32/34/3500)direct 63 A (iEM3100), 125 A (iEM3300) external CT 63 to 2000 ACommunication ports RS-485, M-Bus in selected referencesRS-485, M-Bus, BACnet, LonWorks in selected references1 WirelessInputs / Outputs 1/1 (in selected)upto 2 Inputs and 1 Output 2 I/OMemory capacitypage 37 page 42 page 48 page 54POWERLOGIC™ CATALOG PANORAMA5Version: 1.0 - 30/05/2022PLSED310126EN_01b
Panorama of the PowerLogic™ range (cont'd)Wireless products Basic multi-function meteringName PowerTag Control HeatTag Smart SensorPM5000 Series PM5350 SeriesFunctionCircuit monitoring & controlIEC 60364-8-1EN 17267ISO 50010Early detection of overheating wire connections or overheating cablesmetering & sub-meteringClass 0.5S IEC 62053-22Class 1 IEC 62053-21Class 2 IEC 62053-23Class 0.5/1 IEC 61557-12Class 0.5S IEC 62053-22Class 2 IEC 62053-23Class 1 IEC 61557-12ApplicationsPanel instrumentationPanel instrumentation Analysis of gas and micro-particles, Temperature, HumidityI, U, F, P, Q, S, PF, E(Power demand andcurrent demand)I, U, F, P, Q, S, PF, E(Power demand andcurrent demand)Energy efficiency and costSub-billing & cost allocation Demand & load managementBilling analysisPower availability & reliabilityCompliance monitoringDip/swell, transientHarmonicsRevenue meteringRevenue meterCharacteristicsMeasurement accuracyTemperature ±-1.1 °CHumidity ± 9 RH%Class 0.5S Class 0.5Installation DIN rail DIN rail6 x 18 mm modulesFlush mount 96 mm x 96 mm or DIN rail (PM5563)Flush mount96 mm x 96 mmVoltage measurement20 V to 400 V AC L-N 35 V to 690 V AC L-L20 V to 300 V L-N 35 V to 520 V L-LCurrent measurementexternal CT external CTCommunication ports Wireless RS-485, Ethernet, BACnet, Ethernt IPRS-485Inputs / Outputs2 I/Oupto 4 inputs/ 2 outputs upto 4 inputs/ 2 outputsMemory capacity Availablepage 97 page 101 page 105 page 118POWERLOGIC™ CATALOG PANORAMAVersion: 1.0 - 30/05/2022PLSED310126EN_01b6
EcoStruxure™ Panel ServerName EcoStruxure™ Panel ServerFunctionIoT gateway for intelligent power network FeaturesRS-485 / Ethernet gateway Supports IEEE 802.15.4 and Modbus devicesDevices supportedWired devices communicating though Modbus-SL, Modbus TCP/IP, or digital inputs: Circuit breakers and switch-disconnectors, Protection relays,Power meters, Energy meters, Pulse meters, IO modules, GatewaysWireless devices: PowerTag Energy sensors, Environmental sensors, Acti9 Active, HeatTage sensors, PowerTag Control modules, Wireless indication auxiliaries for ComPacT NSX and ComPacT NSXm, circuit breakersWeb server with standard HTML pagesWeb server with custom HTML pagesReal time dataAvailable on web server embedded in Panel ServerHistorical data Available on web server embedded in Panel Server(Advanced Panel Server only)Automatic notificationAvailable on embedded web server (Advanced Panel Server only), edge control system & cloud-hosted applicationAlarm and event logsAvailable on embedded web server (Advanced Panel Server only), edge control system & cloud-hosted applicationWaveform displayCustom animated graphicsManual/automatic reportsCharacteristicsEthernet portsModbus TCP/IP protocolTwo Ethernet 10Base-T/100Base-T portWi-FiBluetooth communication for commissioningModbus RS485 serial communicationIEEE 802.15.4 wireless communicationModbus TCP/IP server and clientSupport of HTTPS, NTP, SNTP, DHCP client and server with proxy managementModbus RS485 to Modbus/TCP GatewayWireless devices concentrator to Modbus/TCPTwo digital inputs (24VDC version only) Commissioning through EcoStruxure™ Power Commission or through Embedded Web-PagesRS-485 (2-wire / 4-wire) ports, Modbus protocolNumber of devices connected directlyRS-232 configuration portsMiscellaneousInstallationpage 125Panorama of the PowerLogic™ range (cont'd)POWERLOGIC™ CATALOG PANORAMA7Version: 1.0 - 30/05/2022PLSED310126EN_01b
CURRENT TRANSFORMERS FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 09/05/2022PLSED310126EN_028Current transformersSchneider Electric is the global specialist in energy management with the most complete power monitoring product line. Current Transformers are essential components designed to be used with Schneider Electric's extensive power monitoring product portfolio. From simple energy meters to world class power quality meters, these proven products satisfy any requirement.056854NMD-2056852NMD-2PB100316-35METSECT5CC04METSECT5MB025METSECT5CYL1METSECT5GD025METSECT5HA025PB119864PB119872
CURRENT TRANSFORMERS FUNCTIONS AND CHARACTERISTICS9Version: 1.0 - 09/05/2022PLSED310126EN_02CT with let-through primaryConductor type Cable Mixed, bars or cables Vertical or horizontal bars Vertical barsSuggested Current Transformer and mountingDB415986DB415920DB415988DB415989DB415921DB415987Ratings (A) 40 to 250 150 to 800 200 to 4000 5000 to 6000CT internal profileType C Type M Type D (1)Type VMAMBMCMD(1) Two secondary connectors (parallel internal wiring - only one secondary winding) for easier cable access. 1 lateral + 1 on one extremity. Warning: only one must be used at a time.Specific mounting: use of cylinderA cylindrical metallic spacer ensures a proper CT positioning when the conductor or the CT cannot be positioned perpendicular. Secured by bolt + nut.CT with primary connection by screw and nut (example: use of cylinder with bar or cable)DB416005METSECT5CYL1 (aluminium) 16550 (brass)DB416186Application diagram of a CT.VVThe Ip/5 A ratio current transformer delivers at the secondary a current (Is) of 0 to 5 A that is proportional to the current measured at the primary (Ip). This allows them to be used in combination with measurement equipment:•Ammeters• Kilowatt-hour meters• Measurement units• Control relays• etc.When the primary is energized, the measurement equipment nearly acts as a short circuit which keeps the secondary voltage very low. This voltage will increases significantly if the short circuit is removed.CT selection - conductor rating aspectsThe choice depends on the conductor profile and the maximum intensity of the primary circuit.Ip/5 A ratioDB416006NOTE: This document is not intended to be used as an installation guide.FF CFF MAFF MDFF DFF V2
CURRENT TRANSFORMERS FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 09/05/2022PLSED310126EN_0210CT selection - Electrical aspect Ip/5 A• We recommend that you choose the ratio immediately higher than the maximum measured current (In).Example: In = 1103 A; ratio chosen = 1250/5.• For small ratings: From 40/5 to 75/5 and for an application with digital devices, we recommend that you choose a higher rating, forexample 100/5. This is because small ratings are less accurate and the 40 A measurement, for example, will be more accurate with a100/5 CT than with a 40/5 CT.• Specific case of the motor starter: to measure motor starter current, you must choose a CT with primary currentIp = Id/2 (Id = motor starting current).Validation of measurement solution according to accuracy classIt consists in controlling the right adaptation of the CT on the accuracy class aspect. The accuracy class is specified in the project. The total dissipated power of the measurement circuit (meter + cables) should not be superior to the specified limit of the CT. This limit is for different standard classes. If necessary, the choice of the cable section, the CT or meter should be modified to fit the requirement.Copper cable cross-section (mm2)Power per doubled meter at 20 °C (VA)Schneider Electric deviceConsumption of the current input (VA)Ammeter 72 x 72 / 96 x 961.1Analog ammeter 1.1Digital ammeter 0.3PM8000 0.15PM3000 0.3PM5000iEM30001 11.5 0.6852.5 0.414 0.2546 0.16910 0.097516 0.062Application exampleProject specification: 200 A, in Ø27 mm cable, accuracy class 1.Our choice is METSECT5MA020.For this CT selected on the chart (next page), the max acceptable power is 7 VA (for "Accuracy class 1" which is specified in the project).Control of the conformity of the measurement chain: b PM3000 multi-meter: 0.3 VA. b 4 meters of 2.5 mm2, doubled wires: 0.41 x 4 = 1.64 VA.Total: 0.3 + 1.64 = 1.94 VA (< 7 VA)Conclusion: this CT is well adapted as the accuracy class will be even better than 1.For each temperature variation per 10 °C bracket, the power drawn up by the cables increases by 4 %.Internal profile typeCables (mm)Bars (mm)Rating Ip/5 A (A)Commercial reference numberAccuracy class0.5 1 3Max. power (VA)MAØ27 10 x 3215 x 25150 METSECT5MA0153 4 -200 METSECT5MA0204 7 -250 METSECT5MA0256 8 -300 METSECT5MA0308 10 -400 METSECT5MA04010 12 -FF ME DANGERHAZARD OF ELECTRICAL SHOCK, EXPLOSION OR ARC FLASH• Apply appropriate personal protective equipment (PPE) and follow safe electrical work practices. See NFPA 70E, CSA Z462 or equivalent local standards.• Turn off all power supplying this device and the equipment in which it is installed before working on the device or equipment.• Always use a properly rated voltage sensing device to confirm power is off.• Treat I/O wiring connected to multiple devices as hazardous live until determined otherwise.• Do not exceed the device's ratings for maximum limits.• Do not use this device for critical control or protection applications where human or equipment safety relies on the operation of the control circuit.• Disconnect all the device's input and output wires before perfroming dielectric (hi-pot) or Megger testing.CT DAMAGE• Never open circuit a current transformer (CT).• Do not attempt to repair any component if the CT.Failure to follow these instructions will result in death or serious injury.
CURRENT TRANSFORMERS FUNCTIONS AND CHARACTERISTICS11Version: 1.0 - 09/05/2022PLSED310126EN_02Type C - solid core current transformer (cable prole)Internal profile typeCables (mm)Bars (mm)Rating Ip/5 A (A)Commercial ref numberCCØ21 - 40 METSECT5CC00450 METSECT5CC00560 METSECT5CC00675 METSECT5CC008100 METSECT5CC010125 METSECT5CC013150 METSECT5CC015200 METSECT5CC020250 METSECT5CC025Type M - current transformers (mixed: cable/bar profile)MBØ26 12 x 40 15 x 32250 METSECT5MB025300 METSECT5MB030400 METSECT5MB040MAØ27 10 x 32 15 x 25150 METSECT5MA015200 METSECT5MA020250 METSECT5MA025300 METSECT5MA030400 METSECT5MA040MCØ32 10 x 40 20 x 32 25 x 25250 METSECT5MC025300 METSECT5MC030400 METSECT5MC040500 METSECT5MC050600 METSECT5MC060800 METSECT5MC080MDØ40 12 x 50 20 x 40500 METSECT5MD050600 METSECT5MD060800 METSECT5MD080PB112446METSECT5CCpppMETSECT5MBpppPB112460PB112462METSECT5MAppp METSECT5MCpppMETSECT5MDpppPB112461PB112463See your Schneider Electric representative for complete ordering information.FF MCFF MDFF MBFF MAFF CCPB118085
CURRENT TRANSFORMERS FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 09/05/2022PLSED310126EN_0212Type C - solid core current transformer (cable prole)Internal profile typeAccuracy class Overall dimensions (refer to drawing pages for details) W x H x D (mm)Fastening mode Accessories0.5 1 3 CylinderMax. power (VA)CC Dimension (mm)Commercial ref no.- - 1 44 x 66 x 37 b Adapter for DIN rails. b Mounting plate.16550METSECT5CYL1Included- 1.25 1.5- 1.25 2- 1.5 2.52 2.5 3.52.5 3.5 43 4 54 5.5 65 6 7MB3 5 - 60 x 85 x 63 b Adapter for DIN rails. b Mounting plate.- METSECT5COVER4 6 -6 8 -MA3 4 - 56 x 80 x 63 b Adapter for DIN rails. b Mounting plate.METSECT5CYL2 METSECT5COVER4 7 -6 8 -8 10 -10 12 -MC3 5 - 70 x 95 x 65 b Adapter for DIN rails. b Mounting plate.- METSECT5COVER5 8 -8 10 -10 12 -12 15 -10 12 -MD4 6 - 70 x 95 x 65 b Adapter for DIN rails. b Mounting plate.- METSECT5COVER6 8 -8 12 -Common characteristicsSecondary current Is (A) 5 AMaximum voltage rating Ue (V) 720 VFrequency (Hz) 50/60 HzSafety factor (sf) 40 to 4000 A: sf y 55000 to 6000 A: sf y 10Degree of protection IP20Operating temperature tropicalised range-25°C to +60°C (1)relative humidity > 95 %Storage temperature -40°C to +85°CCompliance with standards IEC 61869-2VDE 0414Secondary connection (as per model) by terminals for lugby tunnel terminalsby screws(1) Warning: some products are limited to +50°C.DIN rail mounting.DB415927DB415926Mounting plate installation.See your Schneider Electric representative for complete ordering information.NOTE: This document is not intended to be used as an installation guide.FF CCFF MBFF MAFF MCFF MDPB112451PB112452
CURRENT TRANSFORMERS FUNCTIONS AND CHARACTERISTICS13Version: 1.0 - 09/05/2022PLSED310126EN_02METSECT5VVpppPB112454PB112455METSECT5DAppp METSECT5DBpppPB112456PB112457METSECT5DCppp METSECT5DDpppPB112459METSECT5DEppp METSECT5DHpppType V - current transformers (vertical bar profile)Internal profile typeCables (mm)Bars (mm)Rating Ip/5 A (A)Commercial reference numberVV- 55 x 165 5000 METSECT5VV500 g6000 METSECT5VV600 gType D - current transformers (vertical or horizontal bar - dual secondary terminals)DA32 x 65 400 METSECT5DA040500 METSECT5DA050600 METSECT5DA060800 METSECT5DA0801000 METSECT5DA1001250 METSECT5DA125 g1500 METSECT5DA150 gDB- 38 x 127 1000 METSECT5DB1001250 METSECT5DB125 g1500 METSECT5DB150 g2000 METSECT5DB200 g2500 METSECT5DB250 g3000 METSECT5DB300 gDC- 52 x 127 2000 METSECT5DC200 g2500 METSECT5DC250 g3000 METSECT5DC300 g4000 METSECT5DC400 gDD- 34 x 84 1000 METSECT5DD1001250 METSECT5DD125 g1500 METSECT5DD150 gDE- 54 x 102 1000 METSECT5DE1001250 METSECT5DE125 g1500 METSECT5DE150 g2000 METSECT5DE200 gDH- 38 x 102 1250 METSECT5DH125 g1500 METSECT5DH150 g2000 METSECT5DH200 gg Operating temperature: -25 °C to 50 °C PB112467See your Schneider Electric representative for complete ordering information.FF V2PB112458
CURRENT TRANSFORMERS FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 09/05/2022PLSED310126EN_0214Type V - solid core current transformers (vertical bar profile)Internal profile typeAccuracy class Overall dimensions (refer to drawing pages for details) W x H x D (mm)Fastening mode Accessories0.5 1 3 Cylinder Sealable coverMax. power (VA)VV Dimension (mm) .60 - - 175 x 273.5 x 110 b Insulated locking screw. - Included70 - -Type D - solid core current transformers (vertical or horizontal bar - dual secondary terminals)DA Dimension (mm)4 8 - 90 x 94 x 90 b Insulated locking screw. Included8 10 -8 12 -12 15 -15 20 -15 20 -20 25 -DB6 10 - 99 x 160 x 87 b Insulated locking screw. - Included8 12 -10 15 -15 20 -20 25 -25 30 -DC25 30 - 125 x 160 x 87 b Insulated locking screw. - Included30 50 -30 50 -30 50 -DD10 15 - 96 x 116 x 87 b Insulated locking screw. - Included12 15 -15 20 -DE12 15 - 135 x 129 x 85 b Insulated locking screw. - Included15 20 -20 25 -20 25 -DH12 15 - 98 x 129 x 75 b Insulated locking screw. - Included12 15 -20 25 -g Operating temperature: -25 °C to 50 °C See your Schneider Electric representative for complete ordering information.FF V2
CURRENT TRANSFORMERS DIMENSIONS AND CONNECTIONVersion: 1.0 - 09/05/2022PLSED310126EN_0215CC internal profile type MB internal profile typeDB416965MA internal profile type MC internal profile typeDB415922DB415939MD internal profile type DA internal profile typeDB416966DB415932DB internal profile type DC internal profile typeDB416967DB416968DB415923Solid core CT dimensions
CURRENT TRANSFORMERS DIMENSIONS AND CONNECTIONVersion: 1.0 - 09/05/2022PLSED310126EN_0216DD internal profile type DE internal profile typeDB416969DB416970DH internal profile typeDB416971VV internal profile typeDB416972Solid core CT dimensions contd.NOTE: This document is not intended to be used as an installation guide.
CURRENT TRANSFORMERS DIMENSIONS AND CONNECTIONVersion: 1.0 - 09/05/2022PLSED310126EN_0217Solid core cylinders dimensionsCylindersMETSECT5CYL1 METSECT5CYL2DB416004DB416002Aluminium Aluminium16550 16551DB416082DB416000Brass BrassCoversMETSECT5COVERDB416008
CURRENT TRANSFORMERS FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 09/05/2022PLSED310126EN_0218Split core CTCT internal profileType H Type G HA HD HG HJ HP GA GD GG GJHM Split core CTsFF CFF HMFF V2Common characteristics Cable CT Bus Bar CTSecondary current Is (A) 5 A 5 AMaximum voltage rating Ue (V) 720 V 720 VFrequency (Hz) 50/60 Hz 50/60 HzSafety factor (sf)up to 1000 A: sf y 5greater than 1000 A: sf y 10up to 1500 A: sf y 5greater than 1500 A: sf y 10Degree of protection IP20 IP20Operating temperature -5°C to +50°Crelative humidity 5-85 %-5°C to +40°Crelative humidity 5-85 %Storage temperature -25°C to +70°C -25°C to +70°CCompliance with standards IEC 61869-1IEC 61869-2IEC 61869-1IEC 61869-2Secondary connection (as per model) by terminals for lugby tunnel terminalsby screwsby terminals for lugby tunnel terminalsby screws DANGERHAZARD OF ELECTRICAL SHOCK, EXPLOSION OR ARC FLASH• Apply appropriate personal protective equipment (PPE) and follow safe electrical work practices. See NFPA 70E, CSA Z462 or equivalent local standards.• Turn off all power supplying this device and the equipment in which it is installed before working on the device or equipment.• Always use a properly rated voltage sensing device to confirm power is off.• Treat I/O wiring connected to multiple devices as hazardous live until determined otherwise.• Do not exceed the device's ratings for maximum limits.• Do not use this device for critical control or protection applications where human or equipment safety relies on the operation of the control circuit.• Disconnect all the device's input and output wires before perfroming dielectric (hi-pot) or Megger testing.CT DAMAGE• Never open circuit a current transformer (CT).• Do not attempt to repair any component if the CT.Failure to follow these instructions will result in death or serious injury.
CURRENT TRANSFORMERS FUNCTIONS AND CHARACTERISTICS19Version: 1.0 - 09/05/2022PLSED310126EN_02Type G - split core current transformers (bus bar)Accuracy classMax power (VA)CT window dimension (mm)Rating Ip/5A (A)Commercial Reference no.0.5 1 3 GA- - 1.25 23 x 33 100 METSECT5GA010- - 1.5 150 METSECT5GA015- - 2.5 200 METSECT5GA020- 1.5 - 250 METSECT5GA025- 3.75 - 300 METSECT5GA0301 - - 400 METSECT5GA040GD- 1.5 - 55 x 85 250 METSECT5GD025- 2.5 - 300 METSECT5GD0301 - - 400 METSECT5GD0402.5 - - 500 METSECT5GD0502.5 - - 600 METSECT5GD0602.5 - - 750 METSECT5GD0752.5 - - 800 METSECT5GD0805 - - 1000 METSECT5GD100GG- 1.5 - 85 x 125 250 METSECT5GG025- 2.5 - 300 METSECT5GG030- 2.5 - 400 METSECT5GG0402.5 - - 500 METSECT5GG0502.5 - - 600 METSECT5GG0602.5 - - 750 METSECT5GG0752.5 - - 800 METSECT5GG0805 - - 1000 METSECT5GG1005 - - 1200METSECT5GG1207.5 - - 1250 METSECT5GG1257.5 - - 1500 METSECT5GG150 GJ10 - - 85 x 165 1000 METSECT5GJ10010 - - 1200 METSECT5GJ12010 - - 1500 METSECT5GJ15010 - - 1600 METSECT5GJ16010 - - 2000 METSECT5GJ20010 - - 2500 METSECT5GJ25015 - - 3000 METSECT5GJ30015 - - 4000 METSECT5GJ400See your Schneider Electric representative for complete ordering information.Split core CTsPB119862PB119864PB119866PB119868METSECT5GApppMETSECT5GDpppMETSECT5GGpppMETSECT5GJppp
CURRENT TRANSFORMERS FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 09/05/2022PLSED310126EN_0220Type H - split core current transformers (cable) Accuracy classMax power (VA)CT window dimension (mm)Rating Ip/5A (A)Commercial Reference no.0.5 1 3 HA- 1 - 18.4 x 19 150 METSECT5HA015- 1.5 - 150 METSECT5HA0201 - - 250 METSECT5HA025HD- 1 - 27.9 x 27 250 METSECT5HD025- 1.5 - 300 METSECT5HD030- 2.5 - 400 METSECT5HD0401 - - 500 METSECT5HD050HG - - 1.5 Ø32.5 100 METSECT5HG010- - 2.5 125 METSECT5HG013- - 3 150 METSECT5HG015- - 3 200 METSECT5HG020- - 3 250 METSECT5HG025- 2.5 - 300 METSECT5HG030- 5 - 400 METSECT5HG040- 5 - 500 METSECT5HG050- 5 - 600 METSECT5HG060 HJ- 2.5 - 42.4 x 43 300 METSECT5HJ030- 5 - 400 METSECT5HJ040- 5 - 500 METSECT5HJ0502.5 - - 600 METSECT5HJ0602.5 - - 750 METSECT5HJ0752.5 - - 800 METSECT5HJ080 HM- 2.5 - 42.4 x 85 300 METSECT5HM030- 5 - 400 METSECT5HM040- 5 - 500 METSECT5HM0502.5 - - 600 METSECT5HM0602.5 - - 750 METSECT5HM0752.5 - - 800 METSECT5HM080 HP- 1.5 - Ø44 250 METSECT5HP025- 2.5 - 300 METSECT5HP030- 5 - 400 METSECT5HP040- 5 - 500 METSECT5HP050- 5 - 600 METSECT5HP060- 5 - 750 METSECT5HP075- 5 - 800 METSECT5HP080- 5 - 1000 METSECT5HP100See your Schneider Electric representative for complete ordering information.Split core CTs contd.PB119872PB119872PB119874PB119876METSECT5HApppMETSECT5HDpppMETSECT5HGpppMETSECT5HJpppMETSECT5HMpppMETSECT5HPpppPB119878PB119874
CURRENT TRANSFORMERS DIMENSIONS AND CONNECTIONVersion: 1.0 - 09/05/2022PLSED310126EN_0221Split core CT dimensionsGA DimensionsGG DimensionsGD DimensionsGJ DimensionsPB119867PB119863PB119865PB119869Gx products
CURRENT TRANSFORMERS DIMENSIONS AND CONNECTIONVersion: 1.0 - 09/05/2022PLSED310126EN_0222HA DimensionsHD DimensionsHG Dimensions HJ DimensionsSplit core CT dimensions contd.Hx productsPB119877PB119875PB119873PB119871
CURRENT TRANSFORMERS DIMENSIONS AND CONNECTIONVersion: 1.0 - 09/05/2022PLSED310126EN_0223HM DimensionsHP DimensionsPB119881PB119879Split core CT dimensions contd.
CURRENT TRANSFORMERS FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 09/05/2022PLSED310126EN_0224PowerLogic™ Rogowski Current TransformerMainMETSECTR30500 METSECTR46500 METSECTR60500 METSECTR90500RangePowerLogic™Product or component type Current transducerAccessory / part category Measurement accessoryRange compatibilityPowerLogic™ EM3500 - EM3555A EM3502A EM3560 EM3550A EM3560 EM3561APowerLogic™ EM4200 - EM4236 EM4235 Acti9 iEM3000 - iEM3555 iEM3565Current transformer type Flexible coreComplementaryElectrical connection Flying lead 2.4 m 600 V AC max, voltage L-N sensed conductorCable 1000 V AC UL style 21223 cable with 22 AWG leadsCurrent range 50 A to 5000 ANetwork frequency 50/60 HzMeasurement accuracy ±1 % from 50 A to 5000 AInstallation category 600 V AC Cat IVPollution degree2 DimensionsMETSECTR30500 METSECTR46500 METSECTR60500 METSECTR90500CT core thickness 8 mm diameter 8 mm diameter 8 mm diameter 8 mm diameterCT core length (open) 300 mm 460 mm 600 mm 900 mmDiameter (closed) 96 mm 146 mm 191 mm 287 mmEnvironmentStandards EN 61010-1, UL 61010-1, EN 61010-2-032, UL 61010-2-032Product certificationsCURusUL recognizedAmbient air temperature for operation-15 ºC to 60 ºCAmbient air temperature for storage -40 ºC to 70 ºCHumidity range 0 to 95 % non-condensingAltitude 2000 m maxProtection degree IP67Commercial Reference NumbersMETSECTR25500PowerLogic™- Rogowski current transformer, 250 mm CT core length, 80 mm dia. CT, rope, 600 V AC, 5 kAMETSECTR30500PowerLogic™- Rogowski current transformer, 300 mm CT core length, 96 mm dia. CT, rope, 600 V AC, 5 kAMETSECTR46500PowerLogic™- Rogowski current transformer, 460 mm CT core length, 146 mm dia. CT, rope, 600 V AC, 5 kAMETSECTR60500PowerLogic™- Rogowski current transformer, 600 mm CT core length, 191 mm dia. CT, rope, 600 V AC, 5 kAMETSECTR90500PowerLogic™- Rogowski current transformer, 900 mm CT core length, 287 mm dia. CT, rope, 600 V AC, 5 kAPB118060METSECTR30500Rogowski CTs
PANEL INSTRUMENTS FUNCTIONS AND CHARACTERISTICS25Version: 1.0 - 30/05/2022PLSED310126EN_03Panel InstrumentsSchneider Electric panel instruments reliably comply with the most stringent standards, including IEC, MID, UL, etc., and we thoroughly test all products with recognized, third-party laboratories. Our products are simple to install, configure, and use. This saves our partners time and money and lets them deliver the best solutions in a timely and cost-effective manner.Whatever the size or type of application, the PowerLogic™ product line is an integral part of smart panels.DB119006PB112024PB101118160291520216003
PANEL INSTRUMENTS FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 30/05/2022PLSED310126EN_0326FunctioniAMPAmmeters measure the current flowing through an electric circuit in amps.iVLTVoltmeters measure the potential (voltage) difference of an electric circuit in volts.Common technical data• Accuracy: Class 1.5• Complies with standards IEC 60051-1, IEC 61010-1 and IEC 61000-4• Ferromagnetic device• Pseudo-linear scale over 90°• Ammeters (except catalog number 16029):– connection on CT, ratio In/5, to be ordered separatelyinterchangeable dials• Temperature:– operating temperature: -25 °C to 55 °C– reference temperature: 23 °C• Influence of temperature on accuracy: ±0.03 %/°C• Utilisation frequency: 50 Hz to 60 Hz• Consumption:– AMP: 1.1 VA– VLT catalog number 15060: 2.5 VA– VLT catalog number 16061: 3.5 VA• Permanent overload:– AMP: 1.2 In– VLT: 1.2 Un• Maximum overload for 5 s:– AMP: 10 In– VLT: 2 Un• Connection: tunnel terminals for 1.5 to 6 mm2 rigid cablesCommercial reference numbersType Scale Connection with CTWidth in mod. of 9 mmComm. ref. no.iAMP with direct connection0-30 A no 8 16029iAMP with connection on CTBasic device (delivered without dial)X/5 8 16030Dial 0-5 A0-50 A 50/5 160320-75 A 75/5 160330-100 A 100/5 160340-150 A 150/5 160350-200 A 200/5 160360-250 A 250/5 160370-300 A 300/5 160380-400 A 400/5 160390-500 A 500/5 160400-600 A 600/5 160410-800 A 800/5 160420-1000 A 1000/5 160430-1500 A 1500/5 160440-2000 A 2000/5 16045iVLT0-300 V 8 160600-500 V 8 16061DB119006iAMPPB112022iVLTSee your Schneider Electric representative for complete ordering information.1602916061
PANEL INSTRUMENTS FUNCTIONS AND CHARACTERISTICS27Version: 1.0 - 30/05/2022PLSED310126EN_03FunctioniAMPAmmeters measure in amps the current flowing through an electric circuit.iVLTVoltmeters measure in volts the potential (voltage) difference of an electric circuit.iFREFrequency meters measure in hertz the frequency of an electric circuit from 20 to 600 V AC.Common technical data• Supply voltage: 230 V AC• Operating frequency: 50 Hz to 60 Hz• Display by red LED: 3 digits, h = 8 mm (0.31 in)• Accuracy at full-scale : 0.5 % ±1 digit.• Consumption: max. 5 VA or rated 2.5 VA• Degree of protection:– IP40 on front face– IP20 at terminal level• Connection: tunnel terminals for 2.5 mm2 cablesSpecific data10 A direct reading ammeter• Minimum value measured: 4 % of rating• Measurement input consumption: 1 VAMulti-rating ammeter• Ratings:– in direct reading: 5 A– by CT (not supplied) configurable on the front face of the ammeter: 10, 15, 20, 25, 40, 50, 60, 100, 150, 200, 250, 400, 500, 600, 800, 1000, 1500, 2000, 2500, 4000, 5000 A• Minimum value measured: 4 % of rating• Measurement input consumption: 0.55 VAVoltmeter• Direct measurement: 0...600 V AC• Input impedance: 2 MW• Minimum value measured: 4 % of ratingFrequency meter• Minimum value measured: 20 Hz• Maximum value measured: 100 Hz• Full-scale display: 99.9 HzCompliance with standards• Safety: IEC/EN 61010-1• EMC electromagnetic compatibility: IEC/EN 65081-1 and IEC/EN 65082-2Commercial reference numbersType Scale Connection with CTWidth in mod. of 9 mmComm. ref. no.Direct reading iAMP0-10 A No 4 15202Multi-rating iAMP0-5000 A As per rating 4 15209iVLT0-600 V 4 15201iFRE20-100 Hz 4 15208PB112024iAMPPB112023iVLTPB112025iFRESee your Schneider Electric representative for complete ordering information.152021520115208
PANEL INSTRUMENTS FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 30/05/2022PLSED310126EN_0328FunctionThe 72 x 72 measurement devices are designed for flush-mounted installation on doors, wicket doors and front plates of enclosures and cubicles.AMPThe ammeters measure in amps the current flowing through an electrical circuit.VLTThe voltmeter measure in volts the potential difference (voltage) of an electrical circuit.Common technical data• Accuracy: Class 1.5• Compliance with standard IEC 60051-1, IEC 61010-1 and IEC 61000-4• Ferromagnetic device• Scale length: 62 mm over 90°• Mounting in enclosure or in cubicle• Degree of protection: IP52• Maximum operating position: 30° / vertical• Temperature:– operation: -25 °C to 50 °C– reference: 23 °C• Influence of temperature on accuracy: ±0.003 %/ °C• Utilisation frequency: 50 Hz to 60 HzAMP specific technical data• Needs a In/5 CT to be ordered separately• Interchangeable dials to be ordered separately• Consumption: 1.1 VA• Permanent overload: 1.2 In• Maximum overload for 5 s: 10 InVLT specific technical data• Consumption: 3 VA• Permanent overload: 1.2 Un• Maximum overload for 5 s: 2 UnCommercial reference numbersType Scale Connection on CT Comm. ref. no.AMP for standard feederBasic device (delivered without dial) X/5 160041.3 In dial 0-50 A 50/5 160090-100 A 100/5 160100-200 A 200/5 160110-400 A 400/5 160120-600 A 600/5 160130-1000 A 1000/5 160140-1250 A 1250/5 160150-1500 A 1500/5 160160-2000 A 2000/5 16019AMP for motor feederBasic device (delivered without dial) X/5 160033 In dial 0-30-90 A 30/5 160060-75-225 A 75/5 160070-200-600 A 200/5 16008VLT0-500 V 16005PB101118-30_cAMP for standard feederPB101119-30_cAMP for motor feederPB101116-30_cVLTSee your Schneider Electric representative for complete ordering information.160091600616005
PANEL INSTRUMENTS FUNCTIONS AND CHARACTERISTICS29Version: 1.0 - 30/05/2022PLSED310126EN_03FunctionThe 96 x 96 measurement devices are designed for flush-mounted installation on doors, wicket doors and front plates of enclosures and cubicles.AMPThe ammeters measure in amps the current flowing through an electrical circuit.VLTThe voltmeter measure in volts the potential difference (voltage) of an electrical circuit.Common technical data• Accuracy: class 1.5• Compliance with standard IEC 60051-1, IEC 61010-1 and IEC 61000-4• Ferromagnetic device• Scale length: 80 mm over 90°• Mounting in enclosure or in cubicle• Degree of protection: IP52• Maximum operating position: 30° / vertical• Temperature:– operation: -25 °C to 50 °C– reference: 23 °C• Influence of temperature on accuracy: ±0.003 % / °C• Utilisation frequency: 50 Hz to 60 HzAMP specific technical data• Needs a In/5 CT to be ordered separately• Interchangeable dials to be ordered separately• Consumption: 1.1 VA• Permanent overload: 1.2 In• Maximum overload for 5S: 10 InVLT specific technical data• Consumption: 3 VA• Permanent overload: 1.2 Un• Maximum overload for 5S: 2 UnCommercial reference numbersType Scale Connection on CT Comm. ref. no.AMP for standard feederBasic device (delivered without dial) X/5 160741.3 In dial0-50 A 50/5 160790-100 A 100/5 160800-200 A 200/5 160810-400 A 400/5 160820-600 A 600/5 160830-1000 A 1000/5 160840-1250 A 1250/5 160850-1500 A 1500/5 160860-2000 A 2000/5 160870-2500 A 2500/5 160880-3000 A 3000/5 160890-4000 A 4000/5 160900-5000 A 5000/5 160910-6000 A 6000/5 16092AMP for motor feederBasic device (delivered without dial) X/5 160733 In dial0-30-90 A 30/5 160760-75-225 A 75/5 160770-200-600 A 200/5 16078VLT0-500 V 16075PB101118-40_cAMP for standard feederPB101119-40_cAMP for motor feederPB101116-40_cVLTSee your Schneider Electric representative for complete ordering information.160791607616075
PANEL INSTRUMENTS FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 30/05/2022PLSED310126EN_0330Common technical data• Durability:– electrical: 100,000 operations– mechanical: 2,000,000 operations• AgNi contact• Operating temperature: -25 °C to 50 °C• Compliance with standards IEC/EN 60947-3• Degree of protection:– IP65 on front face– IP20 at terminal levelCommercial reference numbersType Rating(A)Voltage(V)Number of positionsComm. ref. no.CMA 20 4 16017CMV 500 7 16018ConnectionDB117274CMADB114275CMVReading 3 phase-to-earth voltages + 3 phase-to-phase voltages.Note: when connecting do not remove the pre-cabling.See appropriate Installation Guide for this product.See your Schneider Electric representative for complete ordering information.FunctionThe 48 x 48 selector switches are designed for flush-mounted installation on doors, wicket doors and front plates of enclosures and cubicles.CMAThe ammeter selector switch uses a single ammeter (by means of current transformers) for successive measurement of the currents of a three-phase circuit.CMVThe voltmeter selector switch uses a single voltmeter for successive measurement of the voltages (phase-to-phase and phase-to-neutral) of a three-phase circuit.
PANEL INSTRUMENTS FUNCTIONS AND CHARACTERISTICS31Version: 1.0 - 30/05/2022PLSED310126EN_03FunctioniCMAThis 4-position ammeter selector switch uses a single ammeter (using current transformers) for successive measurement of the currents of a three-phase circuit.iCMVThis 7-position voltmeter selector switch uses a single voltmeter for successive measurement of voltages (phase-to-phase and phase-to-neutral) of a three-phase circuit.Common technical data• Rotary handle• Maximum operating voltage: 440 V, 50/60 Hz• Nominal thermal current: 10 A• Operating temperature: -20 °C to 55 °C• Storage temperature: -25°C to 80°C• Mechanical durability (AC21A-3 x 440 V): 2,000,000 operations• Degree of protection:– IP66 on front face– IP20 at terminal level• Electrical durability: 1,000,000 operations• Connection: jumper terminals with captive screws, for cables up to 1.5 mm2• Complies with standards: IEC/EN 60947-3Commercial reference numbersTypeRating (A)Voltage (V AC)Width in mod. of 9 mmComm. ref. no.iCMA 10 415 4 15126iCMV 10 415 4 15125ConnectionDB114272iCMADB114273iCMVPB107119iCMAPB107118iCMVSee appropriate Installation Guide for this product.See your Schneider Electric representative for complete ordering information.1512615125
PANEL INSTRUMENTS FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 30/05/2022PLSED310126EN_0332FunctionElectromechanical counter that counts the operating hours of a machine or piece of electrical equipment. Giving a precise indication of operating time, the counter is used to decide when to carry out preventive maintenance.Common technical data• Electromechanical display• Maximum display: 99999.99 hours• Display accuracy: 0.01 %• Without reset• Storage temperature: -25 °C to 85 °C• Connection: tunnel terminals for 2.5 mm2 cableSpecific technical dataiCH "DIN"• Consumption: 0.15 VA• Operating temperature: -10 °C to 70 °C• Mounting on DIN railCH "48 x 48"• Consumption:– 15607: 0.25 VA– 15608: 0.15 VA– 15609: 0.02 VA to 12 V and 0.3 VA to 36 V• Operating temperature: -20 °C to 70 °C• Degree of protection: IP65 on front face• Mounting on front face of monitoring switchboardsCommercial reference numbersTypeVoltage(V)Width in mod.of 9 mmComm. ref. no.iCH "DIN" 230 V AC ± 10 %/50 Hz 4 15440CH "48 x 48" 24 V AC ± 10 %/50 Hz 15607230 V AC ± 10 %/50 Hz 1560812 to 36 V DC 15609ConnectionDB114262DB114263iCH "DIN" CH "48 x 48"PB112026iCH "DIN"DB119003CH "48 x 48"loadloadSee appropriate Installation Guide for this product.See your Schneider Electric representative for complete ordering information.1544015607
PANEL INSTRUMENTS FUNCTIONS AND CHARACTERISTICS33Version: 1.0 - 30/05/2022PLSED310126EN_03FunctionElectromechanical counter designed to count impulses emitted by: kilowatt-hour meters, temperature overrun detectors, people meters, speed meters, etc.Common technical data• Supply and metering voltage: 230 V AC ± 10 %, 50/60 Hz• Consumption: 0.15 VA• Maximum display: 9 999 999 impulses• Without reset• Metering data:– minimum impulse time: 50 ms– minimum time between 2 impulses: 50 ms• Storage temperature: -25 °C to 85 °C• Operating temperature: -10 °C to 70 °C• Connection: tunnel terminals for 2.5 mm2 cableCommecial reference numbersType Width in mod. of 9 mm Comm. ref. no.iCI 4 15443ConnectionDB114271iCL.epsiCI impulse counterloadloadSee appropriate Installation Guide for this product.15443
PANEL INSTRUMENTS DIMENSIONS AND CONNECTIONVersion: 1.0 - 30/05/2022PLSED310126EN_0334Analog ammeters and voltmeters iAMP, iVLTDB103473Digital ammeters, voltmeter and frequency meter iAMP, iVLTDB103474iCMA and iCMV selector switchesDB10347572 x 72 analog ammeters and voltmeterDB10347696 x 96 analog ammeters and voltmeterDB103481Protection coverCapot de protectionTerminalM4Protection coverCapot de protectionTerminalM4See the appropriate Installation Guide for this product.
PANEL INSTRUMENTS DIMENSIONS AND CONNECTIONVersion: 1.0 - 30/05/2022PLSED310126EN_033548 x 48 CMA and CMV selector switchesDB103477iCI impulse counter and iCH hour counterDB10347948 x 48 CH hour countersDB1098253.2 (or 4.8)24.1 (or 33)22.3 (or 30.5)(with adapter)See the appropriate Installation Guide for this product.
Basic energy metering Basic energy meters comply with a variety of applications: single-phase or three-phase circuits, basic kWh meters for elementary applications, to full-featured, dual tari energy meters and power metering for network monitoring applications. Data is visible locally or accessible remotely. Wireless communication energy sensors with compact design allow to optimize panel size.• PowerLogic™ iEM2000 series• PowerLogic™ iEM2100 series• PowerLogic™ iEM2400 series• PowerLogic™ iEM3000 series• PowerLogic™ PM3000 series• PowerLogic™ PowerTag Energy seriesPB108450A9MEM1580PB108451PB118059PB113702A9MEM2055A9MEM2000METSEPM3250 A9MEM1580A9MEM2155 A9MEM2435PB118059A9MEM3135PB108450BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 09/05/2022PLSED310126EN_0436
The Acti9 iEM2xxx range energy meters oer a cost-attractive, competitive range of single-phase DIN rail-mounted energy meters ideal for sub-billing, cost allocation applications and support two protocols (Modbus RS-485 or M-Bus) that allow them to integrate seamlessly into any energy monitoring system. Acti9 iEM2xxx RangeiEM2000, iEM2100, iEM2400 seriesApplications• Monitor power consumption for each oor, oce sector, unit or workshop with maximum current from 40 A, 45 A, 63 Aand 100 A• Allocate energy cost to lower cost of operations, optimise building’s power eciency• Connect to power management software to take full advantage of the IoT digital power installation• Various businesses, industrial and residential applicationsPB108451PB118059PB113702A9MEM2435PB118059A9MEM2000A9MEM2055 A9MEM2155BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS37Version: 1.0 - 09/05/2022PLSED310126EN_04
The solution for:All markets that can benet from a solution that includes Acti9 PowerLogic™ iEM2000, iEM2100, iEM2400 series meters:• Buildings• Industry• Data Centre & networks• Infrastructures (airport, road tunnels, telecom...)Competitive advantages*• Compact size - Compatible with Acti9range, 18 mm width in iEM2000, 36 mmwidth in iEM2100 and iEM2400• Display - available in displayless,electromech counter display or LCDdisplay• Communication - Pulse output, ModbusRS-485 or M-Bus communication port• Self-powered, direct connect upto 100 A• MID compliant providing certiedaccuracy and data security• Four quadrant measurement• Two taris• Basic electrical parameter measurementeg. V, I, F, PF, PQSBenetsThe Acti9 PowerLogic™ iEM2xxx meters are economical and easy to install in panelboards and switchboards:• DIN rail mounted, compact size• Accurate data measurement with Class 1 accuracy for kWhand Class 2 accuracy for kVARh*• Measures basic electrical parameters like voltage, current,frequency, power factor and power*Energy management system:To get the most eective use from your Schneider Electric measurement and metering devices, we oer a range of dedicated data loggers and gateways for your building energy management. *in selected references.Conformity of standards• IEC 62052-11• IEC 62053-21• IEC 62053-23*• IEC 61557-12*• EN 50470-1*• EN 50470-3*• IEC 61010-1• CE CertiedSee your Schneider Electric representative for complete ordering information.iEM2xxx Range Feature selectionFunctionsiEM2000T iEM2000/iEM2010iEM2050/ iEM2055iEM2100/iEM2105iEM2110iEM2135/ iEM2155iEM2150iEM2435/ iEM245540A Imaxn n45A Imaxn63A Imaxn n n n100A ImaxnCommunication port RS-485M-Bus (iEM2135) RS-485 (iEM2155)RS-485M-Bus (iEM2435) RS-485 (iEM2455)Pulse output (Energy) 11 (iEM2010)11 (iEM2105)2Digital inputs (Tariff switching)1 1Display Type NoElectromechanical CounterLCDWidth (mm) 18 17.5 36 35.7Multi Tariff counter 2 2 2 2Wh accuracy (IEC 62053-21) Class 1Compliance to IEC 61557-12n n nVARh accuracy (IEC 62053-23)Class 24 Quadrants measurementn nMID Class B (EN 50470-3), 50 Hznn (iEM2055)n n nV A F PFn nPower (P Q S)nP QnBASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 09/05/2022PLSED310126EN_0438
iEM2000, iEM2100, iEM2400 series technical specicationsiEM2000/ iEM2000T/iEM2010iEM2050/iEM2055 iEM2100/iEM2105iEM2110/iEM2135/ iEM2150/iEM2155iEM2435/iEM2455Type of measurement True rms for single-phase AC systems with direct connect/whole current measurementMax. current (Imax) 40 A 45 A 63 A 63 A 100 ABasic current (Inom) 5 A 10 A 5 A 5 AStarting current 40 mA 20 mA 40 mA 15 mA 20 mAVoltage range (L-N) 184 to 276 V AC 195 to 253 V AC 207 to 253 V AC 184 to 276 V AC 195 to 253 V ACFrequency range 50 Hz MID and IEC / 60 Hz IECMax. KWh resolution 999999.9 kWh9999.99 kWh to 99999.9 MWh999.99 kWh/MWh 999999.99 kWh9999.99 kWh to 99999.9 MWhPulse output100 pulses/kWh (120 ms), 5...35 V DC, 1...20 mA (except iEM2000)10000, 2000, 1000, 100, 10, 1, 0.1, 0.01 pulses/kWh(11.2 or 32 ms),5...27 V DC,max 100 mA1 pulse/kWh (200 ms), 18 mA at 24 V DC or 100 mA at 230 V AC (only for iEM2105)1 to 1000 pulses/kWh or kVARh (30 to 100 ms) (only for iEM2110)10000, 2000, 1000, 100, 10, 1, 0.1, 0.01 pulses/kWh,(5...32 ms),5...27 V DC,max 100 mAMeter constant LED3200 ashes per kWh10000 ashes per kWh1000 ashes per kWh1000 ashes per kWh10000 ashes per kWhCable size (power connection) 10 mm210 mm216 mm233 mm235 mm2Cable size (for communications) 4 mm22.5 mm26 mm24 mm22.5 mm2Internal burden, at 240 V L-N, 50 Hz<10 VA <2.5 VA <3 VA <10 VAActive energynReactive energyn n nActive powern n nReactive powern n nApparent powern nPower Factorn n nCurrent and voltagen n nFrequencyn n nLED for local signallingGreen LED: power ONYellow LED: 3200 impulse per kWh Red LED: 10000 impulse per kWhYellow LED: 1000 impulse per kWhYellow LED: 1000 impulse per kWhRed LED: 10000 impulse per kWhCE, UKCA** certicationnIP degree of protectionIP40 front panel and IP20 casingIP51 front panel and IP20 casingIP40 front panel and IP20 casingIP51 front panel and IP20 casingOperating temperature -10°C to +55°C -25°C to +55°CStorage Temperature -40°C to +70°C -30°C to +70°C -25°C to +70°C -25°C to +70°C -30°C to +70°CHumidity at +55°C <95 % <75 % <95 % <95 % <75 %Green Premium product (RoHS, China RoHS, REACH, PEP, EOL)nAltitude <2000 m <2000 m <3000 m <2000 m <2000 mMeasurement category Category IIIPollution degree 2Commercial reference numberA9MEM2000 A9MEM2000TA9MEM2010A9MEM2050A9MEM2055A9MEM2100A9MEM2105A9MEM2110A9MEM2135A9MEM2150A9MEM2155A9MEM2435A9MEM2455Acti9 iEM2xxx Range technical specications** in selected references. BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS39Version: 1.0 - 09/05/2022PLSED310126EN_04
iEM2000/iEM2000T/iEM2010 dimensions iEM2050/iEM2055 dimensionsMaximum diameter power connection clamps 8 mm2 (solid copper). See the appropriate product Installation Guide for complete instructions.Maximum diameter power connection clamps 8 mm2 (solid copper). See the appropriate product Installation Guide for complete instructions.Acti9 iEM2xxx range dimensionsDB116734PB115426iEM2100/iEM2105 dimensionsiEM2435/iEM2455 dimensions iEM2110/iEM2135/iEM2150/iEM2155 dimensionsDB103483PB115003PB11370335.8(1.41)63(2.48)96.71(3.81)4(0.16)ABPlease see the appropriate Installation Guide for accurate and complete information on the installation of this product.BASIC ENERGY METERING DIMENSIONS AND CONNECTIONVersion: 1.0 - 09/05/2022PLSED310126EN_0440
iEM2110/iEM2135/iEM2150/iEM2155 dimensionsiEM2000, iEM2100, iEM2400 series commercial/ordering reference numbersCommercial reference numberProduct descriptionA9MEM2000TiEM2000T energy meter, Class 1, 230 V, 40 A, pulse output, no displayA9MEM2000iEM2000 energy meter, Class 1, 230 V, 40 A, MID, electromechanical counter displayA9MEM2010iEM2010 energy meter, Class 1, 230 V, 40 A, MID, pulse output, electromechanical counter displayA9MEM2050iEM2050 power and energy meter, Class 1, 230 V, 45 A, RS-485, 2 taris, pulse output, LCD displayA9MEM2055iEM2055 power and energy meter, Class 1, 230 V, 45 A, RS-485, MID, 2 taris, pulse output, LCD displayA9MEM2100iEM2100 energy meter, Class 1, 230 V, 63 A, LCD displayA9MEM2105iEM2105 energy meter, Class 1, 230 V, 63 A, pulse output, LCD displayA9MEM2110iEM2110 power and energy meter, Class 1, 230 V, 63 A, MID, 2 taris, 2 pulse outputs, 4 quadrants, LCD displayA9MEM2135iEM2135 power and energy meter, Class 1, 230 V, 63 A, M-Bus, MID, 2 taris, 4 quadrants, LCD displayA9MEM2150iEM2150 power and energy meter, Class 1, 230 V, 63 A, RS-485, 4 quadrants, LCD displayA9MEM2155iEM2155 power and energy meter, Class 1, 230 V, 63 A, RS-485, MID, 2 taris, 4 quadrants, LCD displayA9MEM2435iEM2435 power and energy meter, Class 1, 230 V, 100 A, M-Bus, MID, 2 taris, 2 pulse outputs, 4 quadrants, LCD displayA9MEM2455iEM2455 power and energy meter, Class 1, 230 V, 100 A, RS-485, MID, 2 taris, 2 pulse outputs, 4 quadrants, LCD displaySee your Schneider Electric representative for complete ordering information.Acti9 iEM2xxx range commercial reference numbersBASIC ENERGY METERING COMMERCIAL REFERENCE NUMBERS41Version: 1.0 - 09/05/2022PLSED310126EN_04
ApplicationsCost management applications• Bill checking to verify that you are only charged for the energy you use• Sub-billing individual tenants for their energy consumption, including WAGES• Aggregation of energy consumption, including WAGES, and allocating costs per area, per usage, per shift, orper time within the same facilityNetwork management applications• Basic metering of electrical parameters to better understand the behaviour of your electrical distribution systemActi9 iEM3000 Series The Acti9 iEM3000 series energy meters is a cost-attractive, feature-rich energy metering oer for DIN rail, modular enclosures. With Modbus, BACnet, M-Bus and LON protocol support, you can easily integrate these meters into commercial and non-critical buildings to add simple energy management applications to any BMS, AMR or EMS system. PB113704PB113705PB108450A9MEM3135A9MEM3255A9MEM3150BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 09/05/2022PLSED310126EN_0442
The solution forAll markets that can benet from a solution that includes PowerLogic™ iEM3000 series meters:• Buildings & industry• Data centres and networks• Infrastructure (airports, road tunnels, telecom)Conformity of standards• IEC 61557-12• IEC 62053-21/22• IEC 62053-23• EN 50470-3• EN 50470-1• IEC/EN/UL 61010-1• ANSI C12.20• NMI 14/2/88* and 14/2/89*• UL and CE certied• CAN/CSA-C22.2BenetsOptimise your energy consumption & enable energy eciency practices:• Collect and analyse energy consumption data from eacharea for each type of load or circuit• Gain an accurate understanding of business expenses byallocating the energy-related costs• Identify energy savings opportunities and monitorcontinuously• Use information to implement actions designed to reduceenergy consumptionMonitor the energy consumption of your tenants or customers and establish accurate invoices:• Drive energy-ecient behaviour• Allow building owners to bill tenants for individual measuredutility usage• Give accurate and achievable objectives for energy savingsMore than just kWh meters, the Acti9 iEM3000 series meters provide a full view of both energy consumption and on-site generation with full four-quadrant measurement of active and reactive energy delivered and received. Additionally, extensive real-time measurements (V, I, P, PF) give customers greater detail on their energy usage, and multiple taris give customers the exibility to match the billing structure of their utility.Energy management system:To get the most eective use from your Schneider Electric measurement and metering devices, we oer a range of dedicated data loggers and gateways for your building energy management. * Available in selected referencesCompetitive advantages• Compact size• MID compliant (selected models)providing certied accuracy and datasecurity• Programmable digital inputs/ouputs• Multi-tari capability• Onboard Modbus, LON, M-Bus orBACnet communication*• Baud rate congurable• Communication protection: enable ordisable through communication• A complete range of energy meters• Compatible with Acti9 range• Direct connect upto 125 A• Password: congurable from 0-9999*• Pulse output: congurable pulseconstant (imp/kWh), pulse width (ms)*Features• Multi-line circuit: Measure individual phase energy in threephase network system• Partial and Total energy: Seperate counters for measuringactive, reactive and apparent energy• 4 Quadrant measurement: For measuring quadrant basedpower and energy• Multi tari energy: Upto 4 counters activated through RTC,digital inputs or command register• Digital input/output: For status monitoring/tari control andenergy pulsing/overload alarm• Demand measurement: Per-phase and average current, totalpower for active, reactive and apparent• Current: Direct connected/ whole current with the option of63 A or 125 A, 1 A or 5 A CT operated, LVCT or Rogowskicoil supported• Internal clock: Quartz crystal based back up by supercapacitorBASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS43Version: 1.0 - 09/05/2022PLSED310126EN_04
Acti9 iEM3000 SeriesFeature selectionCurrent Input/ Wh Accuracy iEM3000 series Energy meters63 A Direct/ Class 1 iEM3100 iEM3115 iEM3110 iEM3135 iEM3150 iEM3155 iEM3165 iEM31751 A or 5 A CT/ Class 0.5S iEM3200 iEM3215 iEM3210 iEM3235 iEM3250 iEM3255 iEM3265 iEM3275125 A Direct/ Class 1 iEM3300 iEM3310 iEM3335 iEM3350 iEM3355 iEM3365 iEM33751/3rd or 1 V LVCT/ Class 0.5S iEM3455 iEM3465Rogowski coil/ Class 0.5S iEM3555 iEM3565Communication ProtocolModbusn nM-BusnBACnetnLonWorksnMeasurement (Intergrated) Active energy - Total and Partial energyn n n n n n n n4 Quadrant Active, Reactive energy and Apparent energyn n n nMID compliant (Wh)n n n n n nDemand (per-ph & average current, total power for P Q S)n nPeak Demand (per-ph & average current, total power for P Q S)n nMeasurement (Instantaneous) Voltagen n n n nCurrentn n n n nPower - P Q Sn n n n nPower factorn n n n nFrequencyn n n n nMulti-Tari, control byInternal clock 4 4 4 4 4Digital Inputs 4 2 2 2 2Communication - 4 4 4 4Digital inputs For Status, Tariff control or Input monitoring1 1 1 1Tariff control only 2Digital outputs Energy pulsing or Overload alarm 1 1 1Pulse output only 1Internal clockQuartz crystal based n n n n nDate/time format (DD-MMM-YYYY/hh:mm)n n n n nCommercial referenceCommercial References/ordering referencesA9MEM3100 A9MEM3115 A9MEM3110 A9MEM3135 A9MEM3150 A9MEM3155 A9MEM3165 A9MEM3175A9MEM3200 A9MEM3215 A9MEM3210 A9MEM3235 A9MEM3250 A9MEM3255 A9MEM3265 A9MEM3275A9MEM3300A9MEM3310 A9MEM3335 A9MEM3350 A9MEM3355 A9MEM3365 A9MEM3375A9MEM3455 A9MEM3465A9MEM3555 A9MEM3565See your Schneider Electric representative for complete ordering information.BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 09/05/2022PLSED310126EN_0444
Acti9 iEM3000 SeriesTechnical SpecicationsiEM31xx iEM32xx iEM33xx iEM34xx iEM35xxWidth 18 mm x 5 18 mm x 5 18 mm x 7 18 mm x 5 18 mm x 5 Wiring type (scheme) 3PH3W, 3PH4W, 1PH2W L-N, 1PH2W L-L, 1PH3W L-L-NOperating Temperature-25°C to 55°C/ (-13 °F to 131 °F)-40°C to 70°C/ (-40 °F to 158 °F) for non MID variants-25°C to 70°C (-13 °F to 158 °F)Storage temperature-40 °C to 85 °C (-40 °F to 185 °F)-40 °C to 85 °C (-40 °F to 185 °F)Wiring capacity 16 mm²6 mm² for I and 4 mm² for V50 mm²6 mm² for I and 4 mm² for VLCD display 99999999.9 kWh99999999.9 kWh / MWh99999999.9 kWh 99999999.9 kWh / MWhIP Protection IP40 front, IP20 casingOver voltage and measurement Category III, Pollution Degree 2 Operating Voltage 3 x 100/173 V AC to 3 x 277/480 V AC (50/60 Hz)Operating Current 0.5 A to 63 A 20 mA to 6 A 1 A to 125 A0.022 V to 0.4 V (0.333 V Inom)or0.05 V to 1.2 V (1 V Inom) LVC Ts50 to 5000 ARogowski CoilAltitude < 3000 m (9842 ft) Humidity 5% – 95%Voltage inputsMeasured voltageWye: 100 - 277 V L-N, 173 - 480 V L-L ±20% Delta: 173 - 480 V L-L ±20%Overload 332 V L-N or 575 V L-LImpedance 3 MΩ 3 MΩ 6 MΩ 3 MΩFrequency 50 / 60 Hz ±10%Measurement category IIIMinimum wire temperature ratingrequired90 °C (194 °F) 90 °C (194 °F) 105 °C (221 °F) 90 °C (194 °F)Maximum device consumption- < 10 VA - < 10 VAWire 16 mm2 / 6 AWG 2.5 mm2 / 14 AWG 50 mm2 / 1 AWG 2.5 mm2 / 14 AWGWire strip length 11 mm / 0.43 in 8 mm / 0.31 in 13 mm / 0.5 in 8 mm / 0.31 inTorque 1.8 Nm / 15.9 in•lb 0.5 Nm / 4.4 in•lb 3.5 Nm / 30.9 in•lb 0.5 Nm / 4.4 in•lbCurrent inputsNominal current - 1 A or 5 A - - -Measured current 0.5 A to 63 A 20 mA to 6 A 1 A to 125 A -Withstand 10 A continuous, 20 A at 10 sec/hr - -Minimum wire temperature ratingrequired- 90 °C (194 °F) - 90 °C (194 °F)Impedance < 0.3 mΩ < 1 mΩ < 0.2 mΩ - -Frequency 50 / 60 Hz ±10%Burden < 10 VA at 63 A < 0.036 VA at 6 A < 10 VA at 125 AWire 16 mm2 / 6 AWG 6 mm2 / 10 AWG 50 mm2 / 1 AWG 6 mm2 / 10 AWGWire strip length 11 mm / 0.43 in 8 mm / 0.31 in 13 mm / 0.5 in 8 mm / 0.31 inTorque 1.8 Nm / 15.9 in•lb 0.8 Nm / 7.0 in•lb 3.5 Nm / 30.9 in•lb 0.8 Nm / 7.0 in•lbSplit-core LVCTs - - - 0.333 V or 1 V nominalRogowski Coil - - -U018 Series of Rogowski Coils (up to 5000 A)Minimum wire temperature rating required- - - 90 °C (194 °F)45BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS45Version: 1.0 - 09/05/2022PLSED310126EN_04
Acti9 iEM3000 SeriesMeasurement accuracyAs per IEC62053-21/22/23As per IEC61557-12 As per EN50470-3Current range of operationiEM31xxActive energyClass 1(IEC62053-21)Class 1 (PMD DD) Class BImax=63 A, lref=10 A,Imin=0.5 A, and Ist=0.04 AReactive energyClass 2(IEC62053-23)Class 2 (PMD DD) -Imax=63 A, Ib=10 A, and Ist=0.05 AiEM33xxActive energyClass 1(IEC62053-21)Class 1 (PMD DD) Class BImax=125 A, lref=20 A,Imin=1 A, and Ist=0.08 AReactive energyClass 2(IEC62053-23)Class 2 (PMD DD) -Imax=125 A, Ib=20 A, and Ist=0.1 AiEM32xx (x / 1 A Current input)Active energyClass 1(IEC62053-21)Class 1 (PMD SD, PMD Sx)-Imax=1.2 A, lnom=1 A, and Ist=0.002 AReactive energyClass 2(IEC62053-23)Class 2(PMD Sx)-Imax=1.2 A, lnom=1 A, and Ist=0.003 AiEM32xx (x / 5 A Current input)Active energyClass 0.5S(IEC62053-22)Class 1(PMD SD, PMD Sx)Class CImax=6 A, lnom=5 A, and Ist=0.005 AReactive energyClass 2(IEC62053-23)Class 2(PMD Sx)-Imax=6 A, lnom=5 A,and Ist=0.015 AiEM34xx (LVCT, 0.333/1.0 V at Inom)Field selectableActive energy±1% --Low voltage output for 0.333 V LVCT, Imax=0.399 V, lnom=0.333 V, and Imin=0.022 VReactive energy±2% --iEM35xx(from 50 A to 5000 A)Active energy±1%- -Imax=5000 A, Imin=50 AReactive energy±2%- -Recommended* Schneider make Split-core LVCT for iEM3455 and iEM3465Part Number Sensing Current Frequency OutputLVCT00102S100A 50/60Hz 0 to 1/3VLVCT00202S200A 50/60Hz 0 to 1/3VLVCT00302S300A 50/60Hz 0 to 1/3VLVCT00403S400A 50/60Hz 0 to 1/3VLVCT00603S600A 50/60Hz 0 to 1/3VLVCT00803S800A 50/60Hz 0 to 1/3VLVCT00804S800A 50/60Hz 0 to 1/3VLVCT01004S1000A 50/60Hz 0 to 1/3VLVCT01204S1200A 50/60Hz 0 to 1/3VLVCT01604S1600A 50/60Hz 0 to 1/3VLVCT02004S2000A 50/60Hz 0 to 1/3VLVCT02404S2400A 50/60Hz 0 to 1/3VLVCT00050S50A 50/60Hz 0 to 1/3VLVCT00101S100A 50/60Hz 0 to 1/3VLVCT00201S200A 50/60Hz 0 to 1/3VRogowski Coil for iEM3555 and iEM3565Part NumberSensingCurrentFrequency Lead length (m)Approximate Inside Diameter (mm)METSECTR255005000A 50/60Hz 2.35 80METSECTR305005000A 50/60Hz 2.35 96METSECTR465005000A 50/60Hz 2.35 146METSECTR605005000A 50/60Hz 2.35 191METSECTR905005000A 50/60Hz 2.35 287METSECTR25500LVCT00102SA9MEM3455A9MEM3565* Split core LVCT with 1 V output can also be used.PB108448PB112478PB108449PB118060BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 09/05/2022PLSED310126EN_0446
PB105302PB105303PB105305PB105306iEM3000/iEM3200 series dimensionsActi9 iEM3100/iEM3200 Series front aps open and closediEM3300 series dimensionsActi9 iEM3000 Series parts1. Digital inputs for tariff control (iEM3115 / iEM3215)2. Display for measurement and configuration3. Pulse out for remote transfer (iEM3110 / iEM3210)4. Cancellation5. Confirmation6. Selection7. Flashing yellow meter indicator to check accuracy8. Green indicator: on/off, errorActi9 iEM3000 Series parts1. Digital inputs for tariff control (iEM3115 / iEM3215)2. Display for measurement and configuration3. Pulse out for remote transfer (iEM3110 / iEM3210)4. Cancellation5. Confirmation6. Selection7. Flashing yellow meter indicator to check accuracy8. Green indicator: on/off, errorPB105313PB113599_mPB113598_mPB1053241Please see the appropriate Installation Guide for accurate and complete information on the installation of this product.PB105306Acti9 iEM3000 Series dimensionsBASIC ENERGY METERING DIMENSIONS AND CONNECTIONVersion: 1.0 - 09/05/2022PLSED310126EN_0447
The PowerLogic™ PM3000 series power meters are a cost-attractive, feature-rich range of DIN rail-mounted power meters that oers all the measurement capabilities required to monitor an electrical installation. Ideal for power metering and network monitoring applications that seek to improve the availability and reliability of your electrical distribution system, the meters are also fully capable of supporting sub-metering and cost allocation applications.PM3000 seriesApplicationsCost management applications• Bill checking to verify that you are only charged for the energy you use• Aggregation of energy consumption, including WAGES, and cost allocation per area, per usage, per shift or per timewithin the same facility• Energy cost and usage analysis per zone, per usage or per time period to optimise energy usageNetwork management applications• Metering of electrical parameters to better understand the behaviour of your electrical distribution systemPM3200PM3250BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 09/05/2022PLSED310126EN_0448
The solution forAll markets that can benefit from a solution that includes PowerLogic™ PM3000 series meters:• Buildings• Industry• Data centres and networks• Infrastructure (e.g. airports, road tunnels, telecom)Power management solutionsSchneider Electric provides innovative power management solutions to increase your energy efficiency and cost savings, maximise electrical network reliability and availability, and optimise electrical asset performance.Competitive advantagesConnectivity advantages• Programmable digital input– External tariff control signal (4 tariff)– Remote reset partial counter– External status like breaker status– Collect WAGES pulses• Programmable digital output– Alarm (PM3255)– KWh pulses• Graphic LCD display• Modbus RS-485 with screw terminalsMulti-tariff capabilityThe PM3000 series allows users to arrange KWh consumptionin four different registers. This can be controlled by:• Digital inputs. Signal can be provided by PLC or utilities• Internal clock programmable by HMI• Through communicationThis function allows users to:• Make tenant metering for dual source applications todifferentiate backup source or utility source• Understand well the consumption during peak time and off-peak time, weekdays and weekends, holiday and workingdays etc.• Follow up feeders consumption in line with utility tariffratesBenetsOptimise your energy consumption & enable energy efficiency practices• Collect and analyse energy consumption data from each areafor each type of load or circuit• Gain an accurate understanding of business expenses byallocating the energy-related costs• Identify savings opportunities• Use information to implement actions designed to reduceenergy consumptionConformity of standards• IEC 61557-12• IEC 61326-1• IEC 62052-11• IEC 62053-21• IEC 62053-22• IEC 62053-23• EN 50470-1• EN 50470-3• IEC 61010-1• EN 55022BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS49Version: 1.0 - 09/05/2022PLSED310126EN_04
PM3000 series feature selectionPM3200 PM3210 PM3250 PM3255Performance standardIEC61557-12 PMD/Sx/K55/0.5n n n nGeneralUse on LV and HV systems n n n nNumber of samples per cycle 32 32 32 32CT input 1A/5An n n nVT inputn n n nMulti-tari 4 4 4 4Multi-lingual backlit displayn n n nInstantaneous rms valuesCurrent, voltage Per phase and averagen n n nActive, reactive, apparent power Total and per phasen n n nPower factor Total and per phasen n n nEnergy valuesActive, reactive and apparent energy; import and exportn n n nDemand valueCurrent, power (active, reactive, apparent) demand; presentn n n nCurrent, power (active, reactive, apparent) demand; peakn n nPower quality measurementsTHD Current and voltagen n nData recordingMin/max of the instantaneous valuesn n n nPower demand logsnEnergy consumption log (day, week, month)nAlarms with timestamping 5 5 15Digital inputs/digital outputs 0/1 2/2CommunicationRS-485 portn nModbus protocoln nCommercial reference number METSEPM3200 METSEPM3210 METSEPM3250 METSEPM3255PM3000 seriesSee your Schneider Electric representative for complete ordering information.BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 09/05/2022PLSED310126EN_0450
PowerLogic™ PM3200 front viewPM3000 technical specicationsType of measurementTrue rms up to the 15th harmonic on three-phase (3P,3P+N) and single-phase AC systems. 32 samples per cycleMeasurement accuracyCurrent with x/5A CTs 0.3 % from 0.5 A to 6 ACurrent with x/1A CTs 0.5 % from 0.1 A to 1.2 AVoltage0.3 % from 50 V to 330 V (Ph-N), from 80 V to 570 V (Ph-Ph)Power factor±0.005 from 0.5 A to 6 A with x/5 A CTs; from 0.1A to 1.2 A with x/1 A CTs and from 0.5 L to 0.8 CActive/Apparent Power with x/5A CTs Class 0.5Active/Apparent Power with x/1A CTs Class 1 Reactive power Class 2Frequency 0.05 % from 45 to 65 HzActive energy with x/5A CTs IEC 62053-22 Class 0.5sActive energy with x/1A CTs IEC 62053-21 Class 1Reactive energy IEC 62053-23 Class 2Data update rateUpdate rate 1sInput-voltage characteristicsMeasured voltage50 V to 330 V AC (direct / VT secondary Ph-N)80 V to 570 V AC (direct / VT secondary Ph-Ph)up to 1 MV AC (with external VT)Frequency range 45 Hz to 65 HzInput-current characteristicsCT primary Adjustable from 1 A to 32767 ACT secondary 1 A or 5 AMeasurement input range with x/5A CTs 0.05 A to 6 AMeasurement input range with x/1A CTs 0.02 A to 1.2 APermissible overload 10 A continuous, 20 A for 10s/hourControl PowerAC100/173 to 277/480 V AC (+/-20%), 3 W/5 VA; 45 Hz to 65 HzDC 100 to 300 V DC, 3 WInputDigital inputs (PM3255)11 to 40 V DC, 24 V DC nominal, <=4mA maximum burden, 3.5kVrms insulationOutputDigital output (PM3210)Optocoupler, polarity sensitive, 5 to 30 V, 15 mA max, 3.5kVrms insulationDigital outputs (PM3255)Solid state relay, polarity insensitive, 5 to 40 V, 50 mA max, 50 Ω max, 3.5kVrms insulationPM3000 seriesPowerLogic™ PM3250 front viewBASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS51Version: 1.0 - 09/05/2022PLSED310126EN_04
g Protected throughout by double insulationPM3000 seriesPM3000 technical specicationsMechanical characteristicsWeight 0.26 kgIP degree of protection (IEC 60529) IP40 front panel, IP20 meter bodyDimension 90 x 95 x 70 mmEnvironmental conditionsOperating temperature -25 ºC to 55 ºCStorage temperature -40 ºC to 85 ºC Humidity rating 5 to 95% RH at 50 ºC (non-condensing)Pollution degree 2Metering category III, for distribution systems up to 277/480 V ACDielectric withstand As per IEC61010-1, Doubled insulated front panel displayAltitude 3000 m maxElectromagnetic compatibilityElectrostatic dischargeLevel IV (IEC 61000-4-2)Immunity to radiated elds Level III (IEC 61000-4-3) Immunity to fast transientsLevel IV (IEC 61000-4-4)Immunity to surge Level IV (IEC 61000-4-5)Conducted immunity Level III (IEC 61000-4-6)Immunity to power frequency magnetic elds0.5mT (IEC 61000-4-8)Conducted and radiated emissions Class B (EN 55022)SafetyCE as per IEC 61010-1gCommunicationRS-485 port Half duplex, from 9600 up to 38400 baud, Modbus RTU (double insulation)Display characteristicsDimensions (VA) 43 mm x 34.6 mmDisplay resolution 128 x 96 dotsStandard complianceIEC 61557-12, EN 61557-12IEC 61010-1, UL 61010-1IEC 62052-11, IEC 62053-21, IEC 62053-22, IEC 62053-23EN 50470-1, EN 50470-3BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 09/05/2022PLSED310126EN_0452
PM3250/PM3255 dimensionsPM3250/PM3255 mountingPM3200/PM3210 dimensionsPM3200/PM3210 mountingPM3200/PM3210 overviewPM3250/PM3255 overviewPlease see the appropriate Installation Guide for accurate and complete information on the installation of this product.PM3000 dimensionsPM32 Imax: 6A 903.5464.32.53702.76451.77873.43953.74PM32 Imax: 6A D01 D02 9064.3704587101.53.542.762.531.773.434.00PM32 PM32 Imax: 6A S0+CDAGHHBEFIID01D02PM32 PM32 Imax: 6A C/- DI1 CDI2 DO1DO20V D0/- D1/+FGA BC DJKKEHILL12Click!12Click!Pulse output for remote transfer (PM3210) Energy pulse LED (5000 / kWh)CancellationConfirmationUpDownDisplay with white backlightSealing pointsSealable coversABCDEFGHIDigital inputs x 2 (PM3255)Digital outputs x 2 (PM3255)Communications portCommunications LEDEnergy pulse LED (5000 / kWh)CancellationConfirmationUpDownDisplay with white backlightSealing pointsSealable coversABCDEFGHIJKLBASIC ENERGY METERING DIMENSIONS AND CONNECTIONVersion: 1.0 - 09/05/2022PLSED310126EN_0453
PowerTag Energy is a wireless-communication energy sensor.PowerTag Energy is designed specically for Energy Management, Load Monitoring and Power Availability applications. Associated to a concentrator or a gateway, PowerTag Energy provides a full wireless class 1 solution to monitor energy at any level of a distribution panel.Applications:• Monitors your electrical installation from main incomer down to load level• Suitable for various businesses, buildings, industrial and residential applications with easy integration in upper systems• Supports and enables Energy Eciency programs and standards such as:- European Energy Eciency Directive (EED)- Energy Performance of Buildings Directive (EPBD)- IEC 60364-8-1 “Low Voltage Electrical installations - Energy Eciency”- EN 17267 “Energy Measurement and Monitoring plan”- ISO 50001 “Energy Management System”PowerLogic™ PowerTag Energy seriesPowerTag EnergyMonoconnect 63 A (M63)PowerTag Energy PhaseNeutral 63 A (P63)PowerTag Energy Flex 63 A (F63)PowerTag Energy Flex 160 A (F160)PowerTag Energy Monoconnect 250 A (M250)PowerTag Energy Rope 2000 A (R2000)A9MEM1570A9MEM1590A9MEM1580A9MEM1521LV434020A9MEM1571BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 09/05/2022PLSED310126EN_0454
The solution for Markets that benet from a solution that includes PowerLogic™ PowerTag Energy series: • Residential• Small business• Medium & large buildings• Industrial sitesEnergy management system To get the most eective use from your Schneider Electric measurement and metering devices, we oer a range of dedicated gateways / concentrators depending on your application.Advantages • Wireless-communication• Range up to 2000 A• Voltage loss alarming• Class 1 accuracy• Compact design• Easy installation andcommissioning• Scalable solution• Perfect for retrot or new panelsBenets PowerTag Energy sensor incorporates all features required to perform accurate real-time measurements (U, V, I, P, PF) and energy values up to 2000 A. Dierent designs of PowerTag Energy are available to ensure it ts the protective device on which it is mounted. • PowerTag Energy Monoconnect (M): can bemounted directly on the device, no additional wiringis required• PowerTag Energy PhaseNeutral (P): for DIN oerswith 9 mm pitch between phase and neutral• PowerTag Energy Flex (F): can be mounted ona wide range of protective devices thanks to itsdesign• PowerTag Energy Rope (R) thanks to its openablecurrent sensors can be easily installed onbusbars or wires in new installations and in retrotapplicationsPowerTag Energy sensor is acting as an autonomous meter. Energy counters are stored inside PowerTag Energy sensor.Conformity of standards • IEC 61557-12• IEC 61010-1• IEC 61010-2-030• IEC 61326-1 (IndustrialEnvironment)• IEC 62311• ETSI EN 300 328• ETSI EN 301 487-1• ETSI EN 301 489-17 (RadiatedEMC)BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS55Version: 1.0 - 09/05/2022PLSED310126EN_04
A9MEM15•• A9MEM15•• A9MEM15•• A9MEM1580 LV434020/LV434021Product name M63 P63 F63 F160 M250Max current (I Max) A 63 63 63 160 250Starting current (Ist) 40 mA 40 mA 40 mA 100 mA 160 mADesign Monoconnect PhaseNeutral Flex Flex MonoconnectMounting type On device On device On wires On wires On deviceCurrent sensors type Solid core Solid core Solid core Solid core Solid corePoles1P + W / 1P+N / 3P / 3P+N1P+N / 3P+N 1P+N / 3P / 3P+N 3P / 3P+N 3P / 3P+NSelf-poweredn n n n nVoltage (L-N) Depends on ref 200 - 240 V AC Depends on ref 100 - 277 V AC 230 V ACMeasurements*Nb quadrant 2 2 2 4 4Active Energy Class 1 Class 1 Class 1 Class 1 Class 1Reactive Energy n nApparent Energy nActive Power n n n n nReactive Power n nApparent Power n n n n nPower Factor n n n n nFrequency n nCurrent and Voltage n n n n n* Data availability depending on the concentrator / gatewayLV434022/LV434023 A9MEM1590 A9MEM1591 A9MEM1592 A9MEM1593Product name M630 R200 R600 R1000 R2000Max current (I Max) A 630 200 600 1000 2000Starting current (Ist) 400 mA 120 mA 400 mA 600 mA 1.2 ADesign Monoconnect Rope Rope Rope RopeMounting type On device On wires On wires On wires On wiresCurrent sensors type Solid core Split core Split core Split core Split corePoles 3P / 3P+N 3P / 3P+N 3P / 3P+N 3P / 3P+N 3P / 3P+NSelf-powered n n n n nVoltage (L-N) 230 V AC 100 - 277 V AC 100 - 277 V AC 100 - 277 V AC 100 - 277 V ACMeasurements*Nb quadrant 4 4 4 4 4Active Energy Class 1 Class 1 Class 1 Class 1 Class 1Reactive Energy n n n n nApparent Energy n n n nActive Power n n n n nReactive Power n n n n nApparent Power n n n n nPower Factor n n n n nFrequency n n n n nCurrent and Voltage n n n n n* Data availability depending on the concentrator / gatewayFeature selectionBASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 09/05/2022PLSED310126EN_0456
Connection possibilitiesNote:• In association with a contactor, a Variable Speed Drive or a motor starter: PowerTag Energy can ONLY beinstalled UPSTREAM these devices.• Some PowerTag Energy can be installed either on the TOP or on the BOTTOM of the protective devices.• Check the possible mounting position as indicated in the “Catalog numbers” chapter.Source SourceLoad LoadPower owPower ow1PowerTag Energy Connected Upstream (U and I) b When breaker is OFF, PowerTag Energy remains energized.2PowerTag Energy Connected Downstream (U and I) PowerTag Energy Connected Upstream (U and I) b When breaker is OFF, PowerTag Energy is de-energized. PowerTag Energy sends Voltage loss alarm before complete stop.3PowerTag EnergyConnected Downstream (U and I) 4 b When breaker is OFF, PowerTag Energy remains energized.Power owLoadSourcePower owLoadSource b When breaker is OFF, PowerTag Energy is de-energized. PowerTag Energy sends Voltage loss alarm before complete stop.Main associated concentrators / gateways (*)For Commercial & Building applicationsPowerTag Link EcoStruxure™ Panel Server Wireless Panel Server for PrismaSeT ActiveA9XMWD20A9XMWD20PAS600pFor Small Business applicationsFor Residential applicationsFor Industrial applicationsPowerTag Link C PowerTag Link C+Wiser IP Module Wiser IP Module+Harmony HubA9XELC10EER31800ZBRN1A9XELC10 EER31800 ZBRN1, ZBRN2, ZBRN32(*) Refer to Selection Guide for complete compatibility pages 85 to 95.Connection (Voltage and Current) FeaturesUpstream14• Energy management: consumption in kWh• Load monitoring: real-time measurementsDownstreamPreferred installation to take full benet of voltage loss alarming in diagnosing the load23• Energy management: consumption in kWh• Load monitoring: real-time measurements• Power availability: voltage loss alarmingPB119988A9XMWD20BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS57Version: 1.0 - 09/05/2022PLSED310126EN_04
IEC 61557-12 PMD-I/DD/K55/1 As per the above standard:With its compact design and innovative concept, PowerTag Energy 63 A ts directly on the protective device and as a result has no impact on DIN rail occupancy and switchboard size. It is therefore well adapted to be mounted from head of group down to nal circuits. Since voltage and current are measured directly at the same point on the circuit to be monitored, it provides accurate measurement and relevant information such as voltage loss. PowerTag Energy is compatible with SE product ranges as per the selection guide CA908058.Main characteristicsPowerTag Energy measures the following values in accordance with the IEC61557-12 standard PMD-I/DD/K55/1:• Energy:– Active energy (kWh): total and partial, delivered and received.• Real-time measurement values:– Voltages (V): phase-to-phase and phase-to-neutral.– Currents (A): per phase.– Power:– Active power (W): total and per phase.– Apparent power (VA): total.– Power factor.• Voltage loss alarms:– PowerTag Energy sends a “voltage loss” alarm and the current-per-phase value before being de-energized.– At “voltage loss”, PowerTag Energy adds an overload alarm if the current is higher than the rated current of the associatedprotective device.Note: Functions listed above depends on Concentrator/Gateway.PowerLogic™ PowerTag Energy 63 APB104437PB107143A9MEM1522A9MEM1572PB120058PowerTag EnergyMonoconnect 63 A (M63)PowerTag Energy PhaseNeutral 63 A (P63)PowerTag Energy Flex 63 A (F63)BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 09/05/2022PLSED310126EN_0458
Product selectionNeutral positionSome references of PowerTag Energy 63 A (Monoconnect and PhaseNeutral) exist in Top or Bottom version. This is linked to the position of the neutral of the PowerTag Energy.PowerTag Energy “Top” • Designed tobe mounted onthe Top of thecircuit breaker.PowerTag Energy “Bottom” • Designed to bemounted on theBottom of thecircuit breaker.Note:• Some PowerTag Energy can be installed either on the TOP or on the BOTTOM of the protectivedevices.• Check the possible mounting position as indicated in the “Catalog numbers” chapter.• In association with a contactor, a Variable Speed Drive or a motor starter: PowerTag Energycan ONLY be installed UPSTREAM these devices.Number of polesChoose the PowerTag Energy according to the number of poles of the protective device: one PowerTag Energy per protective device. Ex.: 3 Pole PowerTag Energy 63 A for a 3 pole CB.BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS59Version: 1.0 - 09/05/2022PLSED310126EN_04
PowerLogic™ PowerTag Energy 63 ATechnical specicationsMain characteristicsRated voltage1P+N / 1P+W Un Phase-to-neutral 200… 240 V AC ± 20 %3P Un Phase-to-phase 380… 415 V AC ± 20 %3P+N Un Phase-to-neutral 220… 240 V AC ± 20 %Phase-to-phase 380… 415 V AC ± 20 %A9MEM1543 Un Phase-to-phase 200… 240 V AC ± 20 %A9MEM1564 Un Phase-to-neutral 100… 127 V AC ± 20 %A9MEM1574 Un Phase-to-neutral 120… 137 V AC ± 20 %Phase-to-phase 208… 240 V AC ± 20 %Frequency 50/60 HzMaximum current Imax 63 ABasic current Ib 10 ASaturation current 130 AMaximum consumption 1P+N y 1 VA3P/3P+N y 2 VAStarting current Ist 40 mAAdditional characteristicsOperating temperature -25°C to +60°CStorage temperature -40°C to +85°COvervoltage category As per IEC 61010-1 Cat. IIIMeasuring category As per IEC 61010-2-030 Cat. IIIPollution degree 3Altitude y 2000 mDegree of protection Device only IP20IK 05Radio-frequency communicationISM band 2.4 GHz 2.4 GHz to 2.4835 GHzChannels As per IEEE 802.15.4 11 to 26Isotropic Radiated Power Equivalent (EIRP) 0 dBmMaximum transmission time < 5 msChannel occupancy Messages sent every 5seconds minimumCharacteristics of measuring functionsFunctionSymbolPerformance category as per IEC61557-12 (PMD-I/DD/K55/1)Device measuring rangeClassActive power P 1 9 W to 63 kWActive energy Ea 1 Total and partial 0 to 99999999.9 kWhCurrent I 1 40 mA to 63 AVoltage U 0.5 Un ± 20 %Power factor PFA 1 0 to 1BASIC ENERGY METERING DIMENSIONS AND CONNECTIONVersion: 1.0 - 09/05/2022PLSED310126EN_0460
PowerLogic™ PowerTag Energy 63 APowerTag Energy Monoconnect 63 ACommercial reference numbersPowerTag Energy for Acti9 and Multi9 Monoconnect oers: «Single-terminal» circuit breakers, RCDs and switches with 18 mm pitch between phase and neutral, rating less than or equal to 63 A.Commercial reference numberType Mounting DescriptionA9MEM15201P+wire Top or bottomPowerTag Energy M63 1PWA9MEM15211P+N To pPowerTag Energy M63 1PN TA9MEM1522 Bottom PowerTag Energy M63 1PN BA9MEM1540 3P Top or bottom PowerTag Energy M63 3PA9MEM1543 PowerTag Energy M63 3P 230V LLA9MEM15413P+NTo p PowerTag Energy M63 3PN TA9MEM1542 Bottom PowerTag Energy M63 3PN BDesigned to t the following devices: iC60, Reex iC60, DT60, iID. Check the Concentrators /Gateways compatibility and the list of Schneider Electric compatible devices with the Selection Guide pages 85 to 95.Contact your Schneider Electric representative for complete ordering information.A9MEM1540A9MEM1521A9MEM1542A9MEM1542A9MEM1541A9MEM1541 A9MEM1540A9MEM1521A9MEM1522A9MEM1522A9MEM1520A9MEM1543A9MEM1543A9MEM1520PowerTag Energy PhaseNeutral 63 ACommercial reference numbersPowerTag Energy for Acti9 and Multi9 PhaseNeutral oers: «Single-terminal» circuit breakers, RCDs and switches at pitch of 9 mm between phase and neutral, rating less than or equal to 63 A.Commercial reference numberType Mounting DescriptionA9MEM15611P+N To pPowerTag Energy P63 1PN TA9MEM15621P+N BottomPowerTag Energy P63 1PN BA9MEM15631P+N RCBOBottomPowerTag Energy P63 1PN B RCBO 18mmA9MEM1571 3P+NTo pPowerTag Energy P63 3PN TA9MEM1572 3P+N Bottom PowerTag Energy P63 3PN BDesigned to t the following devices: DT40, iDPN, C40, i DPN Vigi.Check the Concentrators /Gateways compatibility and the list of Schneider Electric compatible devices with the Selection Guide pages 85 to 95.PowerTag Energy Flex 63 ACommercial reference numbersPowerTag Energy Flex for other devices and specic installations, rating less than or equal to 63A.Commercial reference numberType Mounting DescriptionA9MEM15601P+NTop or bottom PowerTag Energy F63 1PNA9MEM15641P+NTop or bottom PowerTag Energy F63 1PN 110VA9MEM1573 3PTop or bottom PowerTag Energy F63 3PA9MEM1570 3P+N Top or bottom PowerTag Energy F63 3PNA9MEM1574 3P+N Top or bottom PowerTag Energy F63 3PN 127/220VDesigned to t the following devices: Vigi iDT40, Vigi iC40, Vigi iC60, iC60 double terminal, iIDdouble terminal.Check the Concentrators /Gateways compatibility and the list of Schneider Electric compatible devices with the Selection Guide pages 85 to 95.A9MEM1561A9MEM1561A9MEM1562A9MEM1562A9MEM1571A9MEM1571A9MEM1572A9MEM1572A9MEM1563A9MEM1563A9MEM1560A9MEM1560A9MEM1573A9MEM1573A9MEM1570A9MEM1570A9MEM1564A9MEM1564A9MEM1574A9MEM1574BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS61Version: 1.0 - 09/05/2022PLSED310126EN_04
PowerTag Energy Monoconnect 63 A connectionPlease refer to PowerTag Energy 63 A Installation Sheet for accurate and complete information on the installation of this product.DB407926Stripping lengthCopper cablesRigid Flexible Flexible with ferruleDB122945DB112804DB123553DB112805DB123554DB12300818 mm1.5 to 16 mm2AWG: 16...62 x 1.5 to 2.5 mm2AWG: 16...141.5 to 16 mm2AWG: 16...62 x 1.5 to 2.5 mm2 AWG: 16...141.5 to 16 mm2AWG: 16...62 x 1.5 to 2.5 mm2AWG: 16...14Mounting with 18 mm ferrule recommended.PowerTag Energy Monoconnect 63 A dimensions (mm)431810004.5Ø 8.51610.5DB407922 4318364.51610.5Ø 8.5DB4079244318544.51610.5Ø 8.5DB4079234318724.51610.5Ø 8.5DB4079251P+wire 1P+N 3P 3P+NPowerTag Energy Monoconnect 63 A weightType Weight (g)1P+wire 16.41P+N 17.53P 283P+N 35BASIC ENERGY METERING DIMENSIONS AND CONNECTIONVersion: 1.0 - 09/05/2022PLSED310126EN_0462
PowerTag Energy PhaseNeutral 63 A connectionPlease refer to PowerTag Energy 63 A Installation Sheet for accurate and complete information on the installation of this product.NDB428718Copper cablesRigid Flexible Flexible with ferruleDB122945DB112804DB123553DB112805DB123554DB1230081.5 to 16 mm2AWG: 16...62 x 1.5 to 2.5 mm2AWG: 16...141.5 to 16 mm2AWG: 16...62 x 1.5 to 2.5 mm2 AWG: 16...141.5 to 16 mm2AWG: 16...62 x 1.5 to 2.5 mm2AWG: 16...14Stripping length: respect the stripping length stated on the device the PowerTagEnergy is associated with.PowerTag Energy PhaseNeutral 63 A dimensions (mm)PowerTag Energy PhaseNeutral 63 A weightType Weight (g)1P+N 183P+N 4844.52003 5918 182081128.5Ø 8.53.52081127DB4286051P+N / 1P+N RCBO 1P+N 1P+N RCBO3811545432004248541818919.5Ø 8.5DB4286063P+NBASIC ENERGY METERING DIMENSIONS AND CONNECTIONVersion: 1.0 - 09/05/2022PLSED310126EN_0463
PowerTag Energy Flex 63 A connectionPlease refer to PowerTag Energy 63 A Installation Sheet for accurate and complete information on the installation of this product.DB428719Copper cablesRigid Flexible Flexible with ferruleDB122945DB112804DB123553DB112805DB123554DB1230081.5 to 16 mm2AWG: 16...62 x 1.5 to 2.5 mm2AWG: 16...141.5 to 16 mm2AWG: 16...62 x 1.5 to 2.5 mm2 AWG: 16...141.5 to 16 mm2AWG: 16...62 x 1.5 to 2.5 mm2AWG: 16...14Stripping length: respect the stripping length stated on the device the PowerTagEnergy is associated with.PowerTag Energy Flex 63 A dimensions (mm)PowerTag Energy Flex 63 A weightType Weight (g)1P+N 163P 383P+N 4044.5200703 1121820Ø 8.5DB42860343200703 154181219.5Ø 8.5DB4286041P+N 3P 3P+N43200703154181219.5Ø 8.5DB428604_2BASIC ENERGY METERING DIMENSIONS AND CONNECTIONVersion: 1.0 - 09/05/2022PLSED310126EN_0464
IEC 61557-12 PMD-I/DD/K55/1 As per the above standard:With its compact design and innovative concept, PowerTag Energy 63 A Resi9 ts directly on the Resi9 protective device and as a result has no impact on DIN rail occupancy and switchboard size. It is therefore well adapted to be mounted from head of group down to nal circuits. Since voltage and current are measured directly at the same point on the circuit to be monitored, it provides accurate measurement and relevant information such as voltage loss.PowerTag Energy 63 A Resi9 is dedicated to the Resi9 range of devices and compatible with Wiser concentrators/gateways.Main characteristicsPowerTag Energy measures the following values in accordance with the IEC61557-12 standard PMD-I/DD/K55/1:• Energy:– Active energy (kWh): total and partial, delivered and received.• Voltage loss alarms:– PowerTag Energy sends a “voltage loss” alarm before being de-energized.– At “voltage loss”, PowerTag Energy adds an overload alarm if the current is higher than the rated current of the associatedprotective device.PowerLogic™ PowerTag Energy 63 A Resi9PB117767PB120177PowerTag EnergyMonoconnect 63 A (M63)PowerTag EnergyMonoconnect 63 A (M63)R9M20BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS65Version: 1.0 - 09/05/2022PLSED310126EN_04
InstallationSome references of PowerTag Energy 63 A Resi9 (Monoconnect) exist in Top or Bottom version. This is linked to the position of the neutral of the PowerTag Energy.PowerTag Energy “Top” • Designed tobe mounted onthe Top of thecircuit breaker.PowerTag Energy “Bottom” • Designed to bemounted on theBottom of thecircuit breaker.Note:• Some PowerTag Energy 63 A Resi9 can be installed either on the TOP or on the BOTTOM ofthe protective devices.• Check the possible mounting position as indicated in the “Catalog numbers” chapter.• In association with a contactor, a Variable Speed Drive or a motor starter: PowerTag Energycan ONLY be installed UPSTREAM these devices.Number of polesChoose the PowerTag Energy according to the number of poles of the protective device: one PowerTag Energy per protective device. Ex.: 3 pole PowerTag Energy 63 A Resi9 for a 3 pole CB.PowerLogic™ PowerTag Energy 63 A Resi9BASIC ENERGY METERING DIMENSIONS AND CONNECTIONVersion: 1.0 - 09/05/2022PLSED310126EN_0466
PowerLogic™ PowerTag Energy 63 A Resi9Technical specicationsMain characteristicsRated voltage1P+N / 1P+W Un Phase-to-neutral 200… 240 V AC ± 20 %3P Un Phase-to-phase 380… 415 V AC ± 20 %3P+N Un Phase-to-neutral 220… 240 V AC ± 20 %Phase-to-phase 380… 415 V AC ± 20 %R9M43 Un Phase-to-phase 200… 240 V AC ± 20 %Frequency 50/60 HzMaximum current Imax 63 ABasic current Ib 10 ASaturation current 130 AMaximum consumption 1P+N y 1 VA3P/3P+N y 2 VAStarting current Ist 40 mAAdditional characteristicsOperating temperature -25°C to +60°CStorage temperature -40°C to +85°COvervoltage category As per IEC 61010-1 Cat. IIIMeasuring category As per IEC 61010-2-030 Cat. IIIPollution degree 3Altitude y 2000 mDegree of protection Device only IP20IK 05Radio-frequency communicationISM band 2.4 GHz 2.4 GHz to 2.4835 GHzChannels As per IEEE 802.15.4 11 to 26Isotropic Radiated Power Equivalent (EIRP) 0 dBmMaximum transmission time < 5 msChannel occupancy Messages sent every 5seconds minimumCharacteristics of measuring functionsFunctionSymbolPerformance category as per IEC61557-12 (PMD-I/DD/K55/1)Device measuring rangeClassActive energy (delivered and received) Ea 1 Total and partial 0 to 99999999.9 kWhCurrent I 1 40 mA to 63 AVoltage U 0.5 Un ± 20 %BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS67Version: 1.0 - 09/05/2022PLSED310126EN_04
PowerLogic™ PowerTag Energy 63 A Resi9PowerTag Energy Monoconnect 63 A Resi9 Commercial reference numbersPowerTag Energy for Resi9 Monoconnect oers: «Single-terminal» circuit breakers, RCDs and switches with 18 mm pitch between phase and neutral, rating less than or equal to 63 A.Commercial reference numberType Mounting DescriptionR9M201P+wire Top or bottomPowerTag Energy R9 M63 1PWR9M211P+N To pPowerTag Energy R9 M63 1PN TR9M22 Bottom PowerTag Energy R9 M63 1PN BR9M40 3P Top or bottom PowerTag Energy R9 M63 3PR9M43 PowerTag Energy R9 M63 3P 230V LLR9M413P+NTo p PowerTag Energy R9 M63 3PN TR9M42 Bottom PowerTag Energy R9 M63 3PN BRefer to the Resi9 catalog in your country to select the right PowerTag Energy model to t on the Resi9 protective device you want to equipped. R9M40R9M21R9M42R9M42R9M41R9M41 R9M40R9M21R9M22R9M22R9M20R9M43R9M43R9M20PowerTag Energy Flex 63 A Resi9 Commercial reference numbersPowerTag Energy Flex for other Resi9 devices and specic installations, rating less than or equal to 63A.Commercial reference numberType Mounting DescriptionR9M601P+NTop or bottom PowerTag Energy R9 F63 1PNR9M70 3P+N Top or bottom PowerTag Energy R9 F63 3PNRefer to the Resi9 catalog in your country to select the right PowerTag Energy model to t on the Resi9 protective device you want to equipped.To allow PowerTag Energy Resi9 F63 to adapt to dierent types of terminals, the voltage tap lugs can be replaced with other end-pieces or lugs for AWG22/0.33 mm2 wires.R9M60R9M60R9M70R9M70BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 09/05/2022PLSED310126EN_0468
PowerTag Energy R9 M63 connectionPowerTag Energy R9 M63 dimensions (mm)431810004.5Ø 8.51610.5DB407922 4318364.51610.5Ø 8.5DB4079244318544.51610.5Ø 8.5DB4079234318724.51610.5Ø 8.5DB4079251P+wire 1P+N 3P 3P+NPowerTag Energy R9 M63 weightType Weight (g)1P+wire 16.41P+N 17.53P 283P+N 35DB429053Stripping length : 18 mmPowerLogic™ PowerTag Energy 63 A Resi9BASIC ENERGY METERING DIMENSIONS AND CONNECTIONVersion: 1.0 - 09/05/2022PLSED310126EN_0469
PowerTag Energy R9 F63 connectionPlease refer to PowerTag Energy 63 A Resi9 Installation Sheet for accurate and complete information on the installation of this product.PowerTag Energy R9 F63 dimensions (mm)PowerTag Energy R9 F63 weightType Weight (g)1P+N 163P 4044.5200703 1121820Ø 8.5DB42860343200703 154181219.5Ø 8.5DB4286041P+N 3P+NDB428719Stripping length: respect the stripping length stated on the device the PowerTag Energy is associated with.PowerLogic™ PowerTag Energy 63 A Resi9BASIC ENERGY METERING DIMENSIONS AND CONNECTIONVersion: 1.0 - 09/05/2022PLSED310126EN_0470
IEC 61557-12 PMD-II/DD/K70/1 As per the above standard:With its ex design this PowerTag Energy can be used on many products or group of loads up to 160 A on 3P or 3P+N networks. Its removable spring connector for voltage picking facilitates its installation, and shapes for brackets allows to mount and maintain it where needed in a panel. Main characteristicsPowerTag Energy Flex 160 A measures the following values in accordance with the IEC 61557-12 standard PMD-II/DD/K70/1:• Energy (4 quadrants):– Active energy (kWh): total and partial, delivered and received.– Active energy per phase (kWh): total and partial, delivered and received.– Reactive energy (kVARh): total and partial, delivered and received.– Reactive energy per phase (kVARh): total and partial, delivered and received.– Apparent energy (kVAh): total and partial.– Apparent energy per phase (kVAh): total and partial.• Real-time measurement values:– Voltages (V): phase-to-phase (U12, U23, U31) and phase-to-neutral (V1N, V2N, V3N).– Currents (A): per phase (I1, I2, I3), calculated neutral current when connected (IN) .– Power:– Active power (W): total and per phase.– Reactive power (VAR): total and per phase.– Apparent power (VA): total and per phase.– Frequency (Hz).– Power factor: total and per phase.• Voltage loss alarms:– PowerTag Energy Flex sensor sends a “voltage loss” alarm and the current-per-phase value before being de-energized.– At “voltage loss”, PowerTag Energy Flex adds an overload alarm if the current is higher than the rated current of the associatedprotective deviceNote: Functions listed above depends on Concentrator/Gateway.PowerLogic™ PowerTag Energy Flex 160 AA9MEM1580PowerTag Energy Flex 160 ABASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS71Version: 1.0 - 09/05/2022PLSED310126EN_04
InstallationPowerTag Energy Flex 160 A can be installed in a panel directly on cables or busbars, associated to a product or not. Voltage pickings removable spring terminal has to be wired by 1 copper wire per phase with following characteristics:Wire rangeNeutral picking shall be connected to have phase-to-neutral voltages, energy per phase and power per phase provided.PowerTag Energy Flex 160 A is mainly advised for ComPact NSXm, ComPact INS160, Acti9 NG125, Acti9C120, PowerPact B, TeSys GV4, and all other devices with a rating between 63A and 160 A. PB120394Solid Stranded Stranded with terminal ends0.2...1.5 mm² 0.2...2.5 mm² 0.25...1.5 mm²24...16 AWG 24...14 AWG 24...16 AWGPowerLogic™ PowerTag Energy Flex 160 ABASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 09/05/2022PLSED310126EN_0472
PowerLogic™ PowerTag Energy Flex 160 A Technical specicationsMain characteristics (as per IEC 61557-12)Rated voltageUn Phase-to-neutral 100...277 V AC ± 20 %Phase-to-phase 173...480 V AC ± 20 %Frequency 50/60 HzMaximum current Imax 160 AMaximum operating current 1.2 x ImaxSaturation current 2 x ImaxMaximum consumption 3 VAStarting current Ist 100 mABasic current Ib 25 AAdditional characteristicOperating temperature -25 °C to +70 °CStorage temperature -40 °C to +85 °COvervoltage category As per IEC 61010-1 Cat. IVMeasuring category As per IEC 61010-2-030 Cat. IVPollution degree 3Altitude Up to 2000 m without derating (1)Degree of protection device IP20IK05Radio-frequency communicationISM band 2.4 GHz 2.4 GHz to 2.4835 GHzChannels As per IEEE 802.15.4 11 to 26Isotropic Radiated Power Equivalent (EIRP) 0 dBmMaximum transmission time < 5 msChannel occupancy For 1 device messages sent every 5 secondsCharacteristics of measuring functionsFunctionSymbolPerformance category as per IEC61557-12 (PMD-II/DD/K70/1)Device measuring rangeClassTotal active power (Active power per phase)P 1 24 W (8 W) to 192 kWTotal reactive power(Reactive power per phase)QA2 30 VAR (10 VAR) to 192 kVARTotal apparent power(Apparent power per phase)SA2 38 VA (13 VA) to 192 kVAActive Energy: per phase, total, partial, delivered and receivedEa1 0 to 281.109 kWhReactive energy:per phase, total, partial, delivered and receivedErA2 0 to 281.109 kVARhApparent energy:per phase, total, partialEapA2 0 to 281.109 kVAhFrequency f 0.5 45 to 65 HzPhase current I 1 100 mA to 320 ANeutral current INC2Voltages (Line to Line) U 0.5 138 to 576 V ACPower factor(per phase, total) PFA1 -1 to 1(1) Above 2000 m, please consult Schneider Electric.BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS73Version: 1.0 - 09/05/2022PLSED310126EN_04
PowerTag Energy Flex 160 A Commercial reference numbersCommercial reference numberType DescriptionA9MEM1580F160 3P/3P+NPowerTag Energy Flex 160 A 3P / 3P+NCheck the Concentrators /Gateways compatibility and the list of Schneider Electric compatible devices with the Selection Guide pages 85 to 95.Contact your Schneider Electric representative for complete ordering information.PowerLogic™ PowerTag Energy Flex 160 AA9MEM1580A9MEM1580PowerTag Energy Flex 160 A dimensionsmmin38.91.5321.40.83DB436016271.06271.0690.83.57==622.44Ø17Ø0.67DB436017PowerTag Energy Flex 160 A weightType Weight (g)F160 3P/3P+N 100Please refer to PowerTag Energy Flex 160 A Installation Sheet for accurate and complete information on the installation of this product.BASIC ENERGY METERING DIMENSIONS AND CONNECTIONVersion: 1.0 - 09/05/2022PLSED310126EN_0474
IEC 61557-12 PMD-II/DD/K70/1 As per the above standard:PowerTag Energy M250/M630 is designed for Molded Case Circuit Breakers and Switches (ComPact, EasyPact CVS and TeSys) for 3P and 3P+N electrical networks. This PowerTagEnergy is mounted directly on the bottom side of the circuit breaker or the Vigi add-on if any. Thanks to its integrated design, it does not require any specic wiring, and is compatible with the same connection accessories than the device it is mounted on.Main characteristicsPowerTag Energy M250/M630 measures the following values in accordance with the IEC61557-12 standard PMD-II/DD/K70/1:• Energy (4 quadrants):– Active energy (kWh): total and partial, delivered and received.– Active energy per phase (kWh): total.– Reactive energy (kVARh): partial, delivered and received.• Real-time measurement values:– Voltages (V): phase-to-phase (U12, U23, U31) and phase-to-neutral (V1N, V2N, V3N).– Currents (A): per phase (I1, I2, I3).– Power:– Active power (W): total and per phase.– Reactive power (VAR): total.– Apparent power (VA): total.– Frequency (Hz).– Power factor.• Voltage loss alarms:– PowerTag Energy sends a “voltage loss” alarm and the current-per-phase value before being de-energized.– At “voltage loss”, PowerTag Energy adds an overload alarm if the current is higher than the rated current of the associatedprotective device.Note: Functions listed above depends on Concentrator/Gateway.PowerLogic™ PowerTag Energy Monoconnect 250 A & 630 ALV434020PowerTag Energy Monoconnect 250 ABASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS75Version: 1.0 - 09/05/2022PLSED310126EN_04
InstallationThe module is self-powered and is installed for xed devices directly on the bottom side of the circuit breaker or Vigi add-on terminals. For plug-in devices, it has to be installed on the base itself, top or bottom.PowerTag Energy M250/M630 3P has to be used with 3P devices, and an external neutral voltage tap is provided in case of the installation has a neutral to provide phase-to-neutral voltages, activeenergy per phase and power per phase. PowerTag Energy M250/M630 3P+N has to be used with 4P devices and with ComPact INS/INV 3P/4P switchesPowerTag M250/M630 modules are compatible with ComPact NSX100/160/250, ComPactNSX400/630, ComPact INS250-100A to 250A, ComPactINS320/400/500/630, ComPactINV100/160/200/250, ComPactINV320/400/500/630, ComPact NS100/160/250, ComPactNS400/630, EasyPact CVS 100-250, EasyPact CVS 400-630, TeSys GV5, TeSys GV6 and TeSys GV7.Important notice : A derating coefficient may apply for the circuit-breaker on which the PowerTag is mounted on. Refer to the circuit breaker catalogue for derating coefficient.In case of retrot, following points have to been checked:• Clearance to be able to add PowerTag Energy module and to respect bending radius of cables.• Condition of power connectors: to be replaced if damaged.• Tightening torques depending of the connector used.LV434022_image-NSX630-3PPowerLogic™ PowerTag Energy Monoconnect 250 A & 630 A NL1L2L3NL1 L2 L3PowerTag 3P PowerTag 3P+NComPact NS, NSX, EasyPact CVS, Tesys GV5, GV6, GV7ComPact NS, NSX, INS, INV, EasyPact CVSPowerTag M250/M630PowerTag M250/M630BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 09/05/2022PLSED310126EN_0476
PowerLogic™ PowerTag Energy Monoconnect 250 A & 630 A Technical specicationsMain characteristicsRated voltageUn Phase-to-neutral 230 VAC ± 20 %Phase-to-phase 400 VAC ± 20 %Frequency 50/60 HzMaximum current Imax 250 A / 630 AMaximum operating current 1.2 x ImaxSaturation current 2 x ImaxMaximum consumption 3.7 VAStarting current Ist 160 mA / 400 mABasic current Ib 40 A / 100 AAdditional characteristicOperating temperature -25 °C to +70 °CStorage temperature -50 °C to +85 °COvervoltage category As per IEC 61010-1 Cat. IVMeasuring category As per IEC 61010-2-030 Cat. IIIPollution degree 3Altitude Up to 2000 m without derating (1)Degree of protection device IP20IK07Radio-frequency communicationISM band 2.4 GHz 2.4 GHz to 2.4835 GHzChannels As per IEEE 802.15.4 11 to 26Isotropic Radiated Power Equivalent (EIRP) 0 dBmMaximum transmission time < 5 msChannel occupancy For 1 device messages sent every 5 secondsCharacteristics of measuring functionsFunctionSymbolPerformance category as per IEC61557-12 (PMD-II/DD/K70/1)Device measuring range(250 A / 630 A)ClassTotal active power (Active power per phase)P 1 88 W (29 W) to 416 kW / 222 W (74 W) to 1048 kWTotal reactive powerQA2 88 VAR to 416 kVAR / 221 VAR to 1048 kVARTotal apparent power SA2 88 VA to 416 kVA / 221 VA to 1048 kVAActive Energy: per phase, total, partialEa1 0 to 281.109 kWhPartial Reactive Energy ErA2 0 to 281.109 kVARhPhase current I 1 160 mA to 500 A / 400 mA to 1260 AVoltages (Line to Line) U 0.5 320 to 480 VACPower factor PFA1 -1 to 1(1) Above 2000 m, please consult us.BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS77Version: 1.0 - 09/05/2022PLSED310126EN_04
PowerTag Energy Monoconnect 250 A & 630 A Commercial reference numbersCommercial reference numberType DescriptionConnection adapter for mounting on plug-in base onlyLV434020M250 3PPowerTag Energy 250 A 3P LV429306LV434021M250 3P+NPowerTag Energy 250 A 3P+N LV429307LV434022 (1)M630 3PPowerTag Energy 630 A 3P LV432584LV434023 (1)M630 3P+NPowerTag Energy 630 A 3P+N LV432585Check the Concentrators /Gateways compatibility and the list of Schneider Electric compatible devices with the Selection Guide pages 85 to 95.(1) For plug-in devices only: when plate mounted, need to add an intercalary wedging plate under the PowerTag Energy module with following dimensions:Contact your Schneider Electric representative for complete ordering information.PowerLogic™ PowerTag Energy Monoconnect 250 A & 630 A LV434020 LV434021LV434022 LV434023LV434020LV434021LV434022LV43402345 4537652 Ø6451809037652 Ø64LV434021_Image-NSX250-4P-WDB432580DB4325813P3P + NBASIC ENERGY METERING DIMENSIONS AND CONNECTIONVersion: 1.0 - 09/05/2022PLSED310126EN_0478
Please refer to PowerTag Energy 250 A & 630 A Installation Sheet for accurate and complete information on the installation of this product.NSX100-250 / NSX400-630 / CVS100-250 / CVS400-630FGXZBA (3P)A (4P)DECYX3P IJH4P HJIKLMYXY(1)(1)(1)3P IJH4P HJIKLMYXY(1)mminAB C D E F GH I JK L M3P 4P3P 4P 3P 4P 3P 4PNSX100-250CVS 100-2501054.131405.5152.52.0680.53.172017.91120.54.74722.83140.553 Ø63 Ø0.236 Ø66 Ø0.23351.34702.7517. 50.6817. 50.681254.9262.52.46401.57NSX400-630CVS 400-6301405.511857.28702.75127.55.0232012.59192.57.57963.78140.556 Ø66 Ø0.236 Ø66 Ø0.23451.77903.522.50.8822.50.88 2007.871003.93652.56NSX100-250 with plug-in base1054.131405.5152.52.061094.2926010.231515.94722.83140.553 Ø63 Ø0.236 Ø66 Ø0.23351.34702.7517. 50.6817. 50.681556.1077.53.05552.16NSX400-630 with plug-in base1405.511857.28702.751536.0240615.982539.961003.93140.554 Ø064 Ø0.236 Ø66 Ø0.23451.77903.522.50.8822.50.882509.841254.92833.26PowerTagZXFGBXDCEYA (3P)A (4P)(1) Only for PowerTag M630(1) Only for PowerTag M630PowerLogic™ PowerTag Energy Monoconnect 250 A & 630 A DB436010_2DB436010_1DB436015 DB436008BASIC ENERGY METERING DIMENSIONS AND CONNECTIONVersion: 1.0 - 09/05/2022PLSED310126EN_0479
INS250 / INV100-250INS320-630 / INV320-630DECABYXFGXZHIKLMXYJPlease refer to PowerTag Energy 250 A & 630 A Installation Sheet for accurate and complete information on the installation of this product.mminA B C D E F G H I J K L MINS250 INV100-2501405.51702.75682.671766.931084.25722.83140.556 Ø66 Ø0.23702.75351.371003.93501.96401.57INS320-630 INV320-6301857.2892.53.64102.54.0327010.62167.56.59963.78140.556 Ø66 Ø0.23903.5451.771505.9752.95652.56PowerTag Energy Monoconnect 250 A & 630 A weightType Weight (g)M250 3P 250M250 3P+N 300M630 3P 800M630 3P+N 1000DB436009DB436012PowerLogic™ PowerTag Energy Monoconnect 250 A & 630 A BASIC ENERGY METERING DIMENSIONS AND CONNECTIONVersion: 1.0 - 09/05/2022PLSED310126EN_0480
IEC 61557-12 PMD-II/DD/K70/1 As per the above standard:With its exible and openable current sensors, this PowerTag Energy Rope can be installed easily on busbars and cables without having to disconnect the conductors, and is suitable for 3P or 3P+N networks. Its removable spring connector for voltage picking facilitates its installation, and the module can be mounted on a DIN rail or maintained with brackets where needed in a panel.Main characteristicsPowerTag Energy Rope measures the following values in accordance with the IEC 61557-12 standard PMD-II/DD/K70/1:• Energy (4 quadrants):– Active energy (kWh): total and partial, delivered and received.– Active energy per phase (kWh): total and partial, delivered and received.– Reactive energy (kVARh): total and partial, delivered and received.– Reactive energy per phase (kVARh): total and partial, delivered and received.– Apparent energy (kVAh): total and partial.– Apparent energy per phase (kVAh): total and partial.• Real-time measurement values:– Voltages (V): phase-to-phase (U12, U23, U31) and phase-to-neutral (V1N, V2N, V3N).– Currents (A): per phase (I1, I2, I3), calculated neutral current when connected (IN).– Power:– Active power (W): total and per phase.– Reactive power (VAR): total and per phase.– Apparent power (VA): total and per phase.– Frequency (Hz).– Power factor: total and per phase.• Voltage loss alarms:– PowerTag Energy Rope sensor sends a “voltage loss” alarm and the current-per-phase value before being de-energized.– At “voltage loss”, PowerTag Energy Rope adds an overload alarm if the current is higher than the rated current of the associatedprotective device.Note: Functions listed above depends on Concentrator/Gateway.PowerLogic™PowerTag Energy Rope 200 A to 2000 APowerTag Energy RopeA9MEM1590BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS81Version: 1.0 - 09/05/2022PLSED310126EN_04
InstallationPowerTag Energy Rope 18 mm module can be mounted on DIN rail or fastened with brackets anywhere in a panel. Then its openable current sensors have to be installed around conductors, cables or busbars, whatever they are insulated or not. Voltage pickings removable spring terminal has to be wired by 1 copper wire per phase with following characteristics:Wire rangeNeutral picking shall be connected to have phase-to-neutral voltages, energy per phase and power per phase provided.PowerTag Energy Rope is mainly advised for ComPact NS, MasterPact NT and NW, MasterPactMTZ NA and HA, for retrot, for group of loads, and for all other devices with a rating up to 2000 A. Solid Stranded Stranded with terminal ends0.2...1.5 mm² 0.2...2.5 mm² 0.25...1.5 mm²24...16 AWG 24...14 AWG 24...16 AWGPB120437PowerLogic™ PowerTag Energy RopeBASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 09/05/2022PLSED310126EN_0482
PowerLogic™ PowerTag Energy Rope 200 A to 2000 A Technical specicationsMain characteristics (as per IEC 61557-12)Rated voltageUn Phase-to-neutral 100...277 VAC ± 20 %Phase-to-phase 173...480 VAC ± 20 %Frequency 50/60 HzMaximum current Imax 200 A / 600 A / 1000 A / 2000 AMaximum operating current 1.2 x ImaxSaturation current 2 x ImaxMaximum consumption 3 VAStarting current Ist 120 mA / 400 mA / 600 mA / 1.2 ABasic current Ib 30 A / 100 A / 150 A / 300 AAdditional characteristicOperating temperature -25 °C to +70 °CMaximum primary conductor temperature 105 °C (2)Storage temperature -40 °C to +85 °COvervoltage category As per IEC 61010-1 Cat. IVMeasuring category As per IEC 61010-2-030 Cat. IVPollution degree 3Altitude Up to 2000 m without derating (1)Degree of protection device IP20 (IP40 front face)IK05Radio-frequency communicationISM band 2.4 GHz 2.4 GHz to 2.4835 GHzChannels As per IEEE 802.15.4 11 to 26Isotropic Radiated Power Equivalent (EIRP) 0 dBmMaximum transmission time < 5 msChannel occupancy For 1 device messages sent every 5 secondsCharacteristics of measuring functionsFunctionSymbolPerformance category as per IEC61557-12 (PMD-II/DD/K70/1)Device measuring range (200 A / 600 A / 1000 A / 2000 A)ClassTotal active power (Active power per phase)P 1 29 W (10 W) to 240 kW / 96 W (32 W) to 720 kW /144 W (48 W) to 1200 kW / 288 W (96 W) to 2400 kWTotal reactive power(Reactive power per phase)QA2 36 VAR (12 VAR) to 240 kVAR / 120 VAR (40 VAR) to 720 kVAR / 180 VAR (60 VAR) to 1200 kVAR / 360 VAR (120 VAR) to 2400 kVARTotal apparent power(Apparent power per phase)SA2 46 VA (15 VA) to 240 kVA / 154 VA (51 VA) to 720 kVA / 231 VA (77 VA) to 1200 kVA / 461 VA (154 VA) to 2400 kVAActive Energy: per phase, total, partial, delivered and receivedEa1 0 to 281.109 kWhReactive energy:per phase, total, partial, delivered and receivedErA2 0 to 281.109 kVARhApparent energy:per phase, total, partialEapA2 0 to 281.109 kVAhFrequency f 0.5 45 to 65 HzPhase current I 1 120 mA to 400 A / 400 mA to 1200 A / 600 mA to 2000 A / 1.2 A to 4000 ANeutral current INC2Voltages (Line to Line) U 0.5 138 to 576 VACPower factor(per phase, total) PFA1 -1 to 1(1) Above 2000 m, please consult us.(2) For higher value, please consult us.BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS83Version: 1.0 - 09/05/2022PLSED310126EN_04
PowerTag Energy Rope 200 A to 2000 ACommercial reference numbersCommercial reference numberType DescriptionA9MEM1590R200 3P/3P+NPowerTag Energy Rope 200 A 3P / 3P+NA9MEM1591R600 3P/3P+N PowerTag Energy Rope 600 A 3P / 3P+NA9MEM1592R1000 3P/3P+N PowerTag Energy Rope 1000 A 3P / 3P+NA9MEM1593R2000 3P/3P+N PowerTag Energy Rope 2000 A 3P / 3P+NCheck the Concentrators /Gateways compatibility and the list of Schneider Electric compatible devices with the Selection Guide pages 85 to 95.PowerLogic™ PowerTag Energy Rope 200 A to 2000 A A9MEM159pA9MEM1590PowerTag Energy Rope 200 A to 2000 A dimensionsPowerTag Energy Rope 200 A to 2000 A weightType Weight (g)R200 3P/3P+N360R600 3P/3P+N R1000 3P/3P+N R2000 3P/3P+N 67.52.631054.13451.771 m3.28 ftØ100Ø3.93180.7mmin.PT_RopeContact your Schneider Electric representative for complete ordering information.Please refer to PowerTag Energy Rope 200 A to 2000 A Installation Sheet for accurate and complete information on the installation of this product.BASIC ENERGY METERING DIMENSIONS AND CONNECTIONVersion: 1.0 - 09/05/2022PLSED310126EN_0484
PowerLogic™ PowerTag EnergySelection guide for product compatibility*(Compatibility for terminal not equipped with comb busbar)PowerTag Energy 63 AProducts(AC network)Mounting positionA9 M63 A9 P63 A9 P63 RCBOA9 F63Acti9/Multi9Circuit breakersiC60/iK60/DT60 To p - - -Bottom - - -iC60 (double terminal) To p - - -Bottom - - -iC40 To p - - -Bottom - - -DT40/iDPN/C40 To p - - -Bottom - - -C120 y 63 ANG125 y 63 ATo p - - - (1)Bottom - - - (1)iC65N-K (China)iC65 (China)To p - - -Bottom - - -iDPN (China) To p - - -Bottom - - -iKQ (1P+W PowerTag on each pole)To p NA - - -Bottom (1P+W only)- - -N40 To p - - -Bottom - - -Reex iC60 Top - - -Bottom - - -Reex XC40 Top - - -Bottom - - - (1)C32/C45/C60/C65/K60/T60/Multi9 OEM (C60N/H/L)To p - - -Bottom - - -Circuit breakers equipped with Vigi moduleiC60/iC65/iC60/iC65N-K with Vigi moduleTo p (CB)- - -Bottom - - - (1) (Vigi) iC40 with Vigi iCG40Top CB - (CB)- -Top (Vigi) - (2) (Vigi 1P+N)- -Bottom (Vigi) - - - (Vigi 3P+N)iC40 with "outgoer" Vigi moduleTo p - (CB)- -Bottom - - - (Vigi)DT40/DPN/C40 with "group feeder" Vigi moduleTop CB - (CB)- -Top Vigi - (Vigi 1P+N)- (Vigi 3P+N)DT40/DPN/C40 with "outgoer" Vigi moduleTo p - (CB)- -Bottom - - - (Vigi)DT60 with Vigi TG60Top CB (CB) only A9MEM1541- - -Top Vigi - - - (1) (Vigi) (1) You may need to change the voltage measurement cable terminals of the PowerTag Energy F63 by other cable ends (wire AWG22/0.33 mm2) for a more suitable connection to this product.(2) Product usually associated with a comb busbar(*) Refer to the product catalog for technical characteristicsBASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS85Version: 1.0 - 09/05/2022PLSED310126EN_04
PowerTag Energy 63 AProducts(AC network)Mounting positionA9 M63 A9 P63 A9 P63 RCBOA9 F63Acti9/Multi9Circuit breakers equipped with Vigi module (cont’)C120 y 63 ANG125 y 63 Awith Vigi moduleTo p - - - (1) (CB) Bottom - - - (1) (Vigi) Circuit breakers equipped with Arc fault detection unitiC60 with ARC unitTo p (CB)- - -Bottom - - - (add-on block) iC40 with ARC unitTo p - (CB)- -Bottom - - - (add-on block) Arc fault detection devicesiC40N ARC / iCV40N VigiARCTo p - --Bottom- --Residual current devicesiID/iID K To p - - -Bottom- - -iID (double terminal) To p - - -Bottom - - -iID40 Top - (2) (1P+N)- (2) (3P+N)Bottom- - -iDPN Vigi "outgoer" 1P+NTo p -- -Bottom -- -iC60H RCBO/iC60H2 RCBO/IKQE RCBOTo p NA (shbone) - - -Bottom - --iC60 RCBO To p - - -Bottom- - -iCV40 "outgoer" 1P+N To p -- -Bottom -- -iCV40 "outgoer" 3P+N To p -- -Bottom - - -DPN Vigi/DT40 Vigi/C40 Vigi "outgoer" 1P+NTo p - - -Bottom -- -DPN Vigi/DT40 Vigi/C40 Vigi/iDPN Vigi "outgoer" 3P+NTo p -- -Bottom - - -DPN Vigi K To p - - - (1)Bottom - - - (1)N40 Vigi "outgoer"To p -- -Bottom -- -iDc/ITG40/C40 Top Left -- -Top Right -- -(1) You may need to change the voltage measurement cable terminals of the PowerTag Energy F63 by other cable ends (wire AWG22/0.33 mm2) for a more suitable connection to this product.(2) Product usually associated with a comb busbar(*) Refer to the product catalog for technical characteristicsPowerLogic™ PowerTag EnergySelection guide for product compatibility*(Compatibility for terminal not equipped with comb busbar)BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 09/05/2022PLSED310126EN_0486
PowerTag Energy 63 AProducts(AC network)Mounting positionA9 M63 A9 P63 A9 P63 RCBOA9 F63Acti9/Multi9Residual current devices (cont’)DCP Vigi Top - - -Bottom - - -C60H RCBO (Multi9) Top NA (shbone) - - -Bottom - - -ID y 63 A/ID K biconnect/ID Type B y 63 ATo p - - -Bottom - - -RED/REDs/REDTest Top - - - (1)Bottom - - - (1)SwitchesiSW y 63 A To p - - -Bottom - - -iSW-NA y 63 A To p - - -Bottom - - -iSW 20/32 A To p - - -Bottom - - -i-NA y 63 A To p - - -Bottom - - -NG125 NA y 63 A Top - - - (1)Bottom - - - (1)Fuse disconnectorsSTI Top - - -Bottom - - -SBI 14x51/SBI 22x58 y 63 A To p - - - (1)Bottom - - - (1)D01/D02 Top - - - (1)Bottom - - - (1)(1) You may need to change the voltage measurement cable terminals of the PowerTag Energy F63 by other cable ends (wire AWG22/0.33 mm2) for a more suitable connection to this product.(*) Refer to the product catalog for technical characteristicsPowerLogic™ PowerTag EnergySelection guide for product compatibility*(Compatibility for terminal not equipped with comb busbar)BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS87Version: 1.0 - 09/05/2022PLSED310126EN_04
(*) Refer to the product catalog for technical characteristicsPowerLogic™ PowerTag EnergySelection guide for product compatibility*(Compatibility for terminal not equipped with comb busbar)PowerTag Energy 63 AProducts(AC network)Mounting positionA9 M63 A9 P63 A9 P63 RCBOA9 F63TeSysMotor circuit breakersGV2 Top - - - (1) (2)Bottom - - - (1) (2)GV3 y 63 A To p - - - (1) (2)Bottom - - - (1) (2)ContactorsTeSys D y 63 A Top - - - Upstream only (1)Bottom - - -TeSys K Top - - - Upstream only (1)Bottom - - -Motor starterTeSys U To p - - - Upstream only (1)Bottom - - -(1) You may need to change the voltage measurement cable terminals of the PowerTag Energy F63 by other cable ends (wire AWG22/0.33 mm2) for a more suitable connection to this product.(2) PowerTag Energy sensors withstand motor starting in-rush currents. Environmental mission prole : Buildings as per 60721-3-3.BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 09/05/2022PLSED310126EN_0488
PowerLogic™ PowerTag EnergySelection guide for product compatibility*(Compatibility for terminal not equipped with comb busbar)PowerTag Energy 160 AProducts(AC network)Mounting positionF160 3P / 3P+NActi9Circuit breakersC120 (with or without Vigi module) 3P / 3P+N Top / BottomNG125 (with or without Vigi module) 3P / 3P+N Top / BottomResidual current devicesiID > 63 A 3P+N Top / BottomRCCB-ID 125 A 3P+N Top / BottomFuse disconnectorsSBI > 63 A 3P / 3P+N Top / BottomSwitchesNG125 NA 3P / 3P+N Top / BottomiSW > 63 A 3P / 3P+N Top / BottomiSW NA > 63 A 3P+N Top / BottomComPactCircuit breakersNSXm 3P / 3P+N Top / Bottom (5)SwitchesNSXm NA 3P / 3P+N Top / Bottom (5)INS 80/100/125/160 3P / 3P+N Top / BottomPowerPactCircuit breakersB 3P / 3P+N Top / Bottom (6)TeSysMotor circuit breakersGV3 > 65 A 3P Top / BottomGV4 3P Top / BottomContactors63 A < TeSys D y 160 A 3P / 3P+N To p Upstream onlyTeSys F y 160 A 3P / 3P+N Top Upstream only(5) It is advised to use EverLink connectors with control wire terminal (LV426970 for 3P / LV426971 for 4P)(6) It is advised to use EverLink connectors with control wire terminal (LV426974 for 3P / LV426975 for 4P)(*) Refer to the product catalog for technical characteristicsBASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS89Version: 1.0 - 09/05/2022PLSED310126EN_04
(1) Consult the ION7550 / ION7650 installation guide for complete specifications. (2) IEC 62051-22B with serial ports only.PowerTag Energy 250 A PowerTag Energy 630 AProducts(AC network)Mounting positionM250 3P M250 3P+N M630 3P M630 3P+NComPactCircuit breakersNSX100/160/250 B/F/N/H/S/L/R/NA Fixed3P Bottom - - -4P Bottom - - -NSX400/630F/N/H/S/L/R/NA Fixed3P Bottom - - -4P Bottom - - -NSX100/160/250 B/F/N/H/S/L/R/NA Plug-In (mounted on the base)3P Top / Bottom - - -4P Top / Bottom - (3)- -NSX400/630F/N/H/S/L/R/NA Plug-In (mounted on the base)3P Top / Bottom - - (4)-4P Top / Bottom - - - (3) (4)NS100/160/250N/SX/H/L/NA Fixed3P Bottom - - -4P Bottom - - -NS400/630N/H/L/NA Fixed3P Bottom - - -4P Bottom - - -NS100/160/250N/SX/H/L/NA Plug-In (mounted on the base)3P Top / Bottom - - -4P Top / Bottom - (3)- -NS400/630N/H/L/NA Plug-In (mounted on the base)3P Top / Bottom - - (4)-4P Top / Bottom - - - (3) (4)Circuit breakers equipped with Vigi blockNSX100/160/250 B/F/N/H/S/L/R/NA Fixed3P Bottom - - -4P Bottom - - -NSX400/630F/N/H/S/L/R/NA Fixed3P Bottom - - -4P Bottom - - -NSX100/160/250 B/F/N/H/S/L/R/NA Plug-In (mounted on the base)3P To p - - -NSX400/630F/N/H/S/L/R/NA Plug-In (mounted on the base)3P To p - - (4)-SwitchesINS250/INV - 100/160/200/2503P Bottom - - -4P Top / Bottom - (3)- -INS/INV - 320/400/500/6303P Bottom - - -4P Top / Bottom - - - (3)TeSysMotor circuit breakersGV5, GV7 3P Bottom - --GV6 3P Bottom - --EasyPactCircuit breakersCVS 100-250 3P Bottom4P BottomCVS 400-630 3P Bottom4P Bottom(3) neutral on the right when mounted on top side(4) when plate mounted, need to add a 4 mm intercalary under the PowerTag module (see ComPact NSX catalog)(*) Refer to the product catalog for technical characteristicsPowerLogic™ PowerTag EnergySelection guide for product compatibility*(Compatibility for terminal not equipped with comb busbar)BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 09/05/2022PLSED310126EN_0490
PowerLogic™ PowerTag EnergySelection guide for product compatibility*(Compatibility for terminal not equipped with comb busbar)(*) Refer to the product catalog for technical characteristicsPowerTag Energy RopeProducts(AC network)Mounting positionR200 3P / 3P+N R600 3P / 3P+N R1000 3P / 3P+N R2000 3P / 3P+NComPactCircuit breakersNS 630b3P / 3P+NTop / Bottom - - -NS 800/10003P / 3P+NTop / Bottom - - -NS 1250/1600/1600b/20003P / 3P+NTop / Bottom - - -SwitchesINS/INV 630b3P / 3P+NTop / Bottom - - -INS/INV 800/10003P / 3P+NTop / Bottom - - -INS/INV 1250/1600/20003P / 3P+NTop / Bottom - - -NS 630b NA3P / 3P+NTop / Bottom - - -NS 800/1000 NA3P / 3P+NTop / Bottom - - -NS 1250/1600/1600b/2000 NA3P / 3P+NTop / Bottom - - -MasterPactCircuit breakersNT 063P / 3P+NTop / Bottom - - -NT 08/103P / 3P+NTop / Bottom - - -NT 12/163P / 3P+NTop / Bottom - - -NW 08/103P / 3P+NTop / Bottom -NW 12/16/203P / 3P+NTop / Bottom - - -SwitchesNT 06 HA3P / 3P+NTop / Bottom - - -NT 08/10 HA3P / 3P+NTop / Bottom - - -NT 12/16 HA3P / 3P+NTop / Bottom - - -NW 08/10 NA/HA/HF3P / 3P+NTop / Bottom - - -NW 12/16/20 NA/HA/HF3P / 3P+NTop / Bottom - - -MTZ1 06 HA3P / 3P+NTop / Bottom - - -MTZ1 08/10 HA3P / 3P+NTop / Bottom - - -MTZ1 12/16 HA3P / 3P+NTop / Bottom - - -MTZ2 08/10 NA/HA/HA103P / 3P+NTop / Bottom - - -MTZ2 12/16/20 NA/HA/HA103P / 3P+NTop / Bottom - - -TeSysContactorsTeSys D > 160 A3P / 3P+N To p Upstream only- --160 A < TeSys F y 2000 A3P / 3P+N To p Upstream only Upstream only Upstream only Upstream onlyOthersCircuit breakers / Switches / Motor circuit breakersAll products below 200 A3P / 3P+NTop / Bottom - --All products between 200 A and 600 A3P / 3P+NTop / Bottom - - -All products between 600 A and 1000 A3P / 3P+NTop / Bottom - - -All products between 1000 A and 2000 A3P / 3P+NTop / Bottom - - -BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS91Version: 1.0 - 09/05/2022PLSED310126EN_04
Concentrators / gatewaysWiser IP module Wiser IP module+ EER31800PowerTag Link C PowerTag Link C+ A9XELC10Smartlink SI B A9XMZA08Smartlink SI D A9XMWA20PowerTag Link A9XMWD20PowerTag Link HD A9XMWD100PowerTag Energy M63A9MEM1520A9MEM1521A9MEM1522A9MEM1540A9MEM1541A9MEM1542A9MEM1543 -PowerTag Energy M63 Resi9R9M20 - - -R9M21- - -R9M22- - -R9M40- - -R9M41- - -R9M42- - -R9M43- - -PowerTag Energy P63A9MEM1561A9MEM1562A9MEM1563A9MEM1571A9MEM1572PowerTag Energy F63A9MEM1560A9MEM1564 - - -A9MEM1570A9MEM1573 - - -A9MEM1574 - - -PowerTag Energy F63 Resi9R9M60 - - -R9M70- - -PowerLogic™ PowerTag EnergySelection guide for concentrators / gateways compatibility*(*) Refer to the product catalog for technical characteristicsBASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 09/05/2022PLSED310126EN_0492
PowerLogic™ PowerTag EnergySelection guide for concentrators / gateways compatibility*(*) Refer to the product catalog for technical characteristicsConcentrators / gatewaysHarmony Hub ZBRN1 ZBRN2 ZBRN32EcoStruxure™ Panel ServerUniversal PAS600pWireless Panel Server for PrismaSeT ActivePowerTag Energy M63A9MEM1520 -A9MEM1521 -A9MEM1522 -A9MEM1540 -A9MEM1541 -A9MEM1542 -A9MEM1543 - -PowerTag Energy M63 Resi9R9M20 - - -R9M21 - - -R9M22 - - -R9M40 - - -R9M41 - - -R9M42 - - -R9M43 - - -PowerTag Energy P63A9MEM1561 -A9MEM1562 -A9MEM1563 -A9MEM1571 -A9MEM1572 -PowerTag Energy F63A9MEM1560A9MEM1564 - -A9MEM1570A9MEM1573A9MEM1574 - -PowerTag Energy F63 Resi9R9M60 - - -R9M70 - - -BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS93Version: 1.0 - 09/05/2022PLSED310126EN_04
PowerLogic™ PowerTag EnergySelection guide for concentrators / gateways compatibility*Concentrators / gatewaysWiser IP module Wiser IP module+ EER31800PowerTag Link C PowerTag Link C+ A9XELC10Smartlink SI B A9XMZA08Smartlink SI D A9XMWA20PowerTag Link A9XMWD20PowerTag Link HD A9XMWD100PowerTag Energy F160A9MEM1580 -(PowerTag Link C+ only)-PowerTag Energy M250-M630LV434020LV434021LV434022LV434023PowerTag Energy R200-R600-R1000-R2000A9MEM1590 -(PowerTag Link C+ only)-A9MEM1591 -(PowerTag Link C+ only)-A9MEM1592 -(PowerTag Link C+ only)-A9MEM1593 -(PowerTag Link C+ only)-(*) Refer to the product catalog for technical characteristicsBASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 09/05/2022PLSED310126EN_0494
PowerLogic™ PowerTag EnergySelection guide for concentrators / gateways compatibility*Concentrators / gatewaysHarmony Hub ZBRN1 ZBRN2ZBRN32EcoStruxure™ Panel ServerUniversal PAS600pWireless Panel Server for PrismaSeT ActivePowerTag Energy F160A9MEM1580PowerTag Energy M250-M630LV434020LV434021LV434022LV434023PowerTag Energy R200-R600-R1000-R2000A9MEM1590A9MEM1591A9MEM1592A9MEM1593(*) Refer to the product catalog for technical characteristicsBASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS95Version: 1.0 - 09/05/2022PLSED310126EN_04
Schneider Electric oers a range of wireless products designed for new builds or retrot installations. These are reliable, low-cost and easy to use wireless solutions with long battery life that does not compromise performance• • PowerLogic™ PowerTag Control• • PowerLogic™ HeatTagWireless productsA9XMC2D3SMT10020WIRELESS PRODUCTS FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 30/05/2022PLSED310126EN_0596
PowerTag Control monitors circuits wirelessly, collecting status of daisy-chained circuit breakers and notifying the data concentrator of information status, such as OF, SD, Contractor or Impulse Relay position indication. These wireless input/output modules allow circuit control and status monitoring. Designed for use in commercial and building applications, they quickly and easily turn your distribution board into a connected panel.PowerTag Control also connects to pulse relays or contactors for remote control within a building management system for non-critical loads, such as lighting. Applications:• Monitors your electrical installation from main incomer down to load level• Suitable for various business, buildings, industrial and residential applications with easy integration in upper systems• Supports and enables Energy eciency programs and standards such as:- European Energy Eciency Directive (EED)- Energy Performance of Buildings Directive (EPBD)- IEC 60364-8-1 “Low Voltage Electrical installations - Energy Eciency”- EN 17267 “Energy Measurement and Monitoring plan”- ISO 50001 “Energy Management Sytem”PowerLogic™ PowerTag ControlA9XMC2D3 Image2A9XMC2D3WIRELESS PRODUCTS FUNCTIONS AND CHARACTERISTICS97Version: 1.0 - 30/05/2022PLSED310126EN_05
Technical characteristicsMain characteristicsPower supply 230 V AC ± 20%Frequency 50/60 HzMaximum consumption IO ≤ 2 VA2DI ≤ 3 VAOperating temperature -25°C to +60°CStorage temperature -40°C to +85°CRelative humidity (60068-2-78) 93 % at 40°COvervoltage category As per IEC 61010-1 Cat. IIIAltitude ≤ 2000 mPollution degree 3Degree of protection according to IEC60529Front face IP40Casing IP20IK 05Characteristics of inputs and outputsDigital inputType 230 V AC, dry contactDigital outputType 230 V AC, dry contactRelay type Normally open or normally closed (3)Applicable voltage on output 230 V AC ± 20%Minimum/maximum current on output 10 mA / 2 AType of output order Pulse or latch (3)Pulse length in control mode with impulse relay Nominal: 300 msRadio-frequency communicationISM band 2.4 GHz 2.4 GHz to 2.4835 GHzChannels As per IEEE 802.15.4 11 to 26Isotropic Radiated Power Equivalent (EIRP) 0 dBmChannel occupancy Messages sent b On event b Periodically (5s nominal)(3) Setting adjustableClip on DIN rail 35 mm.Indifferent position of installation.IP20 IP40DB123313.epsDimensions (mm)6244184585DB429445.epsWeight (g) PowerTag CPowerTag C IO 230 V 80PowerTag C 2DI 230 V 75Connection Power supplyInput/OutputPZ2PZ114 mm6.5 mm4 mm 9 mmDB430161.epsTerminalsTightening torqueCopper cablesRigid Flexible Flexible with ferruleDB122945.epsDB123007.epsDB122946.epsPower supply (Top)2 N.m 1 to 16 mm2 (AWG: 18...6) 0.5 to 10 mm2 (AWG: 21...8) -Input/Output (Bottom)1 N.m1x: 1 to 6 mm2 (AWG: 18...10)2x: 1.5 to 2.5 mm2 (AWG: 16...14)1x: 0.5 to 4 mm2 (AWG: 21...12)2x: 1.5 to 2.5 mm2 (AWG: 16...14)1x: 0.5 to 4 mm2 (AWG: 21...12)2x: -DB123309.epsDB123311.epsPowerTag ControlWIRELESS PRODUCTS FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 30/05/2022PLSED310126EN_0598
PowerTag ControlPowerTag C IO moduleMonitoring / Back loop circuit b "I" digital input terminal b "C" common powered terminal 230 V AC b Assembly and disassembly by operating toggle latches at the top and bottom of the productsPush button b Local output control b Decommissioning b Compatible with horizontal comb busbars 9 mm modules b Automatic cable guiding in the correct position: terminals with guard b Insulated terminals IP20Status LED b Provide information about PowerTag C statusControl circuit b Logical output relay b "O" output terminals 230 V AC - 2 A max.DB430239.epsA9XMC1D3_Image2-65.epsDB430240.epsDB430241.epsDB430238.epsLogo b Wireless communication deviceWIRELESS PRODUCTS FUNCTIONS AND CHARACTERISTICS99Version: 1.0 - 30/05/2022PLSED310126EN_05
PowerTag C 2DI moduleMonitoring circuits b "I" digital input terminals b "C" common powered terminals 230 V AC b Assembly and disassembly by operating toggle latches at the top and bottom of the productsFlush mounted push button b DecommissioningStatus LED b Provide information about PowerTag C statusDB430243.epsA9XMC2D3_Image2-65.epsDB430244.epsDB430245.epsDB430242.eps b Compatible with horizontal comb busbars 9 mm modules b Automatic cable guiding in the correct position: terminals with guard b Insulated terminals IP20Logo b Wireless communication devicePowerTag ControlWIRELESS PRODUCTS FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 30/05/2022PLSED310126EN_05100
The PowerLogic™ HeatTag sensor analyzes gas and airborne particles helping facility manager to anticipate and act before smoke appears or an electrical re starts. Electrical res generate huge losses in commercial and industrial buildings, interrupting production and delaying service delivery. These losses can be prevented if early detection of component overheating is accurately detected and alarmed.PowerLogic™ HeatTag helps prevent electrical cabinets from being damaged by analyzing airborne gas and particles and sending alerts before smoke appears or an electrical re starts. HeatTag is much more than a re or smoke detector - it scientically detects overheating in electrical installations before any damage is done.PowerLogic™ HeatTagWireless Sensor for early detection of overheating cablesPB120568SMT10020WIRELESS PRODUCTS FUNCTIONS AND CHARACTERISTICS101Version: 1.0 - 30/05/2022PLSED310126EN_05
The solution forMarkets that can benet from a solution that includes PowerLogic™ HeatTag smart sensors:• Buildings• Industry• Healthcare• Data Center and networks• InfrastructurePower management solutionsSchneider Electric provides innovative power management solutions to increase your energy eciency and cost savings, maximize electrical network reliability and availability, and optimize electrical asset performance.Competitive advantages• Easy to install and operate• Suitable for non forced ventilated cabinets ≥ IP31• Immediately detects overheating in cables and connections• More than a smoke detector or heat sensor• 3 levels of alert recording• Monitors air quality index• Continous improvements of algorithmsConformity of standards• IEC/UL 61010-1• IEC 61010-2-201• IEC 61326-1• IEC61326-2-3• ETSI EN 301 489-1• ETSI EN 301 489-17• ETSI EN 300 328• EN 62311• EN IEC 63000• IEEE 802.15.4 protocol• FCC and IC certiedBenetsSystem integrators’ benet• Ease of integration• Ease of setup• Cost eectiveness• Seamless integration with EcoStruxure™ solutionsPanel builders’ benet• No settings• Nominal environment auto-learning to avoid false alerts• Concentrator auto-discovery• Alerts generated by a powerful algorithm integrated inHeatTagEnd users’ benet• Ease of use• Prevents re damage and associated costs• Comprehensive, consistent and superior performance• Maximize uptime, eliminate faults, and enhance safetyWIRELESS PRODUCTS FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 30/05/2022PLSED310126EN_05102
HeatTag featuresSensor CharacteristicsTemperature measurementMeasurement range -15 °C / +70 °C (5 °F to 158 °F)Measurement accuracy -1.1 °C / +1.1 °CDefault transmission period60 seconds (higher in case of high wireless data trac)Humidity measurement Measurement range 15–90 %Measurement accuracy ±9 RH %Default transmission period60 seconds (higher in case of high wireless data trac)Air quality Index (0 to 10), alert generation when index ≥10Test alert after pairing During rst 30 minutesEnvironment auto-learning phase8 hours after the rst 30 minutesMechanical CharacteristicsDimensions (W x H x D) 108 x 107 x 55 mmWeight 270 gDegree of protection (IEC 60529) IP 20Electrical CharacteristicsSupply voltage 110–277 V AC, -15 % / +15 %Frequency 50–60 HzMax. consumption 0.1 AOperating temperature -15 °C / +70 °C (5 °F to 158 °F)Storage temperature -20 °C / +85 °C (-4 °F to 185 °F)Relative humidity in operation 15–90 %Altitude of use 0–2000 m (0–6500 ft)Degree of pollution (IEC 60664-1) 3Overvoltage category OVC IIICommercial Reference NumberPowerLogic™ HeatTag Sensor SMT10020NOTE: Do not use HeatTag as a safety device or to replace re protection devices. Please see the appropriate User Guide for this product.HeatTag sensorsHeatTag sensor dimensions. See the appropriate Installation Guide.PowerLogic™HeatTag sensorHeatTag rear view showing fanHeatTag sensor DIN mountedHeatTag simulation algorithm displayPB120568PB120569PB120570PB120573PB120572Q1 110–277 V~ 2 A C Curve or Fast-acting fuseWIRELESS PRODUCTS FUNCTIONS AND CHARACTERISTICS103Version: 1.0 - 30/05/2022PLSED310126EN_05
A range of meters designed for cost management and simple network management. Aordable to buy and easy to choose, the highly-capable PowerLogic™ PM5000 and PM5350 series meters are designed to provide the best combination of features to match all your energy cost management needs.As well as pin-point energy savings, optimal equipment eciency and utilisation, basic multi-function meters perform a high level assessment of the power quality in an electrical network.• • PowerLogic™ PM5000• • PowerLogic™ PM5350• • PowerLogic™ PM5350IB• • PowerLogic™ PM5350PB• • PowerLogic™ PM5350PBasic multi-function meteringPB111770METSEPM5110METSEPM5560PB117510BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 30/05/2022PLSED310126EN_05104
The PowerLogic™ PM5000 series power meters are the new benchmark in affordable, precision metering. The value you want, the precision you need. Compact, affordable power meters with high-end cost capabilities and basic mobile energy management.PowerLogic™ PM5000 series ApplicationsCapable of essential cost management:• Sub-billing/tenant metering (+1)• Equipment sub-billing• Energy cost allocationAlso ideal for electrical network management:• Track real-time power conditions• Monitor control functions• Provide basic power quality values• Detect and capture voltage sag and swell events• Monitor residual current• Analyze equipment and network status• BACnet/IP, EtherNet/IP, and DNP3.0 protocol supportPB118061METSEPM5760(+1) Subjected to local regulations.BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS105Version: 1.0 - 30/05/2022PLSED310126EN_05
The solution forMarkets that can benefit from a solution that includes PowerLogic™ PM5000 series meters:• Buildings• Industry• Healthcare• Data Center and networks• InfrastructurePower management solutionsSchneider Electric provides innovative power management solutions to increase your energy efficiency and cost savings, maximize electrical network reliability and availability, and optimize electrical asset performance.Competitive advantages• Easy to install and operate• Easy for circuit breaker monitoring and control• WAGES monitoring• Data logging up to 16 parameters• Power quality analysis upto 63rd harmonics• Load management combined with alarm and timestamping• High performance and accuracy• Residual Current Monitoring (RCM)• Voltage sag and swell detection with waveform capture• MID ready compliance for legal billing application• BACnet/IP, EtherNet/IP, and DNP3.0 protocol support• PM5310R (+3) and PM5320R (+3) are enabled to connect withLVCT for faster installationsConformity of standardsBenefitsSystem integrators’ benefit• Ease of integration• Ease of setup• Cost effectivenessPanel builders’ benefit• Ease of installation• Cost effectiveness• Aesthetically pleasing• Simplified ordering• LVDC and Analog inputs optionsEnd users’ benefit• Ease of use• Precision metering & sub-billing (+2) • Billing flexibility• Comprehensive, consistent and superior performance• Maximize uptime, eliminate faults, and enhance safety• Cybersecurity features(+2) Subjected to local regulations.(+3) PM5310R and PM5320R must be used with Schneider Electric’s “Quick Click” 3-in-1 LVCTs• IEC 61557-12• IEC 62052-11• IEC 62052-31• IEC 62053-22• IEC 62053-23• IEEE 802.3• EN 50470-1• EN 50470-3• IEC/UL/EN 61010-1• FCC part 15 Class B• EN 55022 Class B• ODVA certification• ANSI C12.1-2008 (PM55xx)• ANSI C12.20 Class 0.2 & 0.5• Align with cyber security guidelinesas per IEC 62443• Type A as per IEC 62020 for RCMCertified according to MID Directive, Annex "B" + Annex "D" for legalmetrology relevant to active electrical energy meters (see Annex MI-003 of MID). Can be used for fiscal (legal) metrology.MIDMID ready compliance, EN 50470-1/3 – Class CMeets IEC 61557-12 PMD/[SD|SS]/K70/0.5 for PM5100 and PM5300Meets IEC 61557-12 PMD/[SD|SS]/K70/0.2 for PM5500• Legal billing compliance– MID compliance is compulsory for billingapplications across Europe– In addition to billing applications, for facilitymanagers responsible for energy cost– MID means same level of quality as a billingmeterBASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 30/05/2022PLSED310126EN_05106
PowerLogic™ PM5100, PM5300 and PM5500 series The PowerLogic™ PM5000 power meter is the ideal fit for cost management applications. Designed for use in both energy management systems and building management systems, it provides the measurement capabilities needed to allocate energy usage, perform tenant metering and sub-billing, pin-point energy savings, optimize equipment efficiency and utilization, and perform a high level assessment of the power quality of the electrical network.In a single 96 x 96 mm unit, with a graphical display, (plus optional remote display) all three phases, neutral and ground can be monitored simultaneously. The bright, anti-glare display features large characters and powerful backlighting for easy reading even in extreme lighting conditions and viewing angles. Easy to understand menus, text in 8 selectable languages, icons and graphics create a friendly environment to learn about your electrical network. Ethernet gateway and enhanced cyber security. These are highly accurate devices with global billing certifications.Applications• Cost management: Cost saving opportunities become clear once you understand howand when your facility uses electricity. The PowerLogic™ PM5000 series meters are idealfor:– Sub-billing / tenant metering: Allows a landlord, property management firm, condominiumassociation, homeowners association, or other multi-tenant property to bill tenants forindividual measured utility (electricity) usage depending on the local regulations. MIDapproved meters for billing applications across Europe.– Cost allocation: Allocate energy costs between different departments (HVAC, indoor andoutdoor lighting, refrigeration, etc.), different parts of an industrial process or differentcost centres. Cost allocation systems can help you save money by making changesto your operation, better maintaining your equipment, taking advantage of pricingfluctuations, and managing your demand.• Network management: Improving reliability of the electrical network is key for successin any business. Monitoring values such as voltage levels, harmonics distortions, voltageunbalance, residual current, voltage sag and swell will help you to ensure proper operation and maintenance of your electrical network and equipment. PowerLogic™ PM5000 series meters are the perfect tool for:– Basic Power Quality monitoring: Power quality phenomena can cause undesirableeffects such as heating in transformers, capacitors, motors, generators andmisoperation of electronic equipment and protection devices.– Min/ Max monitoring (with timestamp): Understanding when electrical parameters,such as voltage, current and power demand, reach maximum and minimum values willgive you the insight to correctly maintain your electrical network and assure equipmentwill not be damaged.– Alarming: alarms help you to be aware of any abnormal behaviour on the electricalnetwork in the moment it happens.– WAGES monitoring: take advantage of the input metering on PM5000 meters tointegrate measurements from third party devices such as water, air, gas, electricity orsteam meters.– Residual current monitoring: measures leakage current flowing in TN & TT networksystem.– Voltage sags and swells: measures and captures wave form in the event of voltagesags and swells in the network.• Main characteristics– Easy to install– Mounts using two clips, in standard cut out for DIN 96 x 96 mm, no tools required.Compact meter with 72 mm (77 mm for PM5500) depth connectable up to 690V L-L without voltage transformers for installations compliant with category III.Optional remote display (PM5563). Ethernet gateway functionality via RS-485 port.– Easy to operate– Intuitive navigation with self-guided, language selectable menus, six lines, fourconcurrent values. Two LEDs on the meter face help the user confirm normaloperation with a green LED - heartbeat/communications indicator, and the amberLED - customizable either for alarms or energy pulse outputs. Onboard web pages (PM5500) show real-time and logged information, and verify communications.– Easy circuit breaker monitoring and control– The PM5300 provides two relay outputs (high performance Form A type) withcapability to command most of the circuit breaker coils directly. For Digital Inputs,monitored switches can be wired directly to the meter without external powersupply by using whetting output voltage.– PM5500 series have 4 status inputs (digital) and 2 digital output (solid state) to use for WAGES monitoring, control and alarm annunciation.Accurate energy measurement for precise cost allocation:PM5100 PM5300 PM5500 PM5600 PM5700IEC 62053-22 (Active Energy) Class 0.5S Class 0.5S Class 0.2S Class 0.2S Class 0.2SPowerLogic™ PM5563 remote display rear ISOPowerLogic™ PM5563 remote display front ISOPowerLogic™ PM5563 meterPM5000 seriesPB118063PB118064 PB118062BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS107Version: 1.0 - 30/05/2022PLSED310126EN_05
*Applicable in specific meter models. 2 alarms for disturbance (Sag/ Swell).– Alarms can be visualized as Active (the ones that have picked up anddid not drop out yet) or Historical (the ones that happened in the past).Alarms can be programmed and combined to trigger digital outputs andmechanical relays (PM5300).– The PM5000 series keeps an alarm log with the active and historical alarmswith date and time stamping. SMTP protocol for receiving alarm conditionsvia email and text. SNTP protocol for date/time network synchronization.• Load timer– A load timer can be set to count load running hours based on a minimumcurrent withdraw, adjustable to monitor and advise maintenancerequirements on the load.• High Performance and accuracy– IEC 61557-12 Performance measuring and monitoring devices (PMD).Denes the performance expectation based on classes. It denes theallowable error in the class for real and reactive power and energy,frequency, current, voltage, power factor, voltage unbalance, voltage andcurrent harmonics (odds), voltage THD, current THD, as well as ratings fortemperature, relative humidity, altitude, start-up current and safety. It makescompliant meters readings comparable - they will measure the same valueswhen connected to the same load.– These types of power quality parameters help to identify the source ofharmonics that can harm transformers, capacitors, generators, motors andelectronic equipment.• Load management– Peak demands with time stamping are provided. Predicted demandvalues can be used in combination with alarms for basic load sheddingapplications.• Alarming with time stamping– A dierent combination of set point driven alarms and digital alarms with 1stime stamping are available in the PM5000 family:Native multi-protocol supportThe PM55/PM56/PM5700 is now easier than ever to integrate into new and existing BMS systems. With native BACnet/IP protocol support, meters can simultaneously communicate via BACnet and Modbus in applications where multiple software systems are used (building management and energy management systems). The PM55/PM56/PM5700 series has been tested and certified in accordance with BACnet Testing Laboratories (BTL) requirements and Ethernet IP protocol as per ODVA requirements. • PM55/PM56/PM5700 Direct metering of neutral current– The PM55/PM56/PM5700 has a fourth CT for measuring neutral current. Indemanding IT applications, where loads are non-linear (i.e. switching power supplies on computers/servers), measuring neutral current is essential toavoid overload and resulting outage.– Power Quality analysis– The PM5000 oers Total Harmonic Distortion (THD/thd), Total Demand– Distortion (TDD) measurements and individual harmonics (odd) magnitudes and angles for voltage and current:PM5100 PM5300 PM55/56/5700Individual Harmonics magnitudesup to 15thmagnitudesup to 31stmagnitudes & angles up to 63rdPM5100 PM5300 PM55/56/5700Set point driven alarms 29 29 29 or 33*Unary 4 4 4Digital – 2 4 or 2Boolean / Logic – – 10Custom defined – – 5PowerLogic™ PM5500 meterPowerLogic™ PM5300 meterPowerLogic™ PM5100 meterPM5000 seriesPB111777PB111772PB111768BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 30/05/2022PLSED310126EN_05108
PM5000 series feature selectionPM5100 PM5300 PM5100 PM5110 PM5310 PM5310R (+4)PM5320 PM5320R (+4)PM5330 PM5340InstallationFast installation, panel mount with integrated displayb b b b b b b bFast installation, DIN rail mountable– – – – – – – –AccuracyClassCL 0.5S CL 0.5S CL 0.5S CL 0.5S CL 0.5S CL 0.5S CL 0.5S CL 0.5SDisplayBacklit LCD, multilingual, bar graphs, 6 lines, 4 concurrent valuesb b b b b b b bPower and energy metering3-ph voltage, current, power, demand, energy, frequency, power factorb b b b b b b bMulti-tariff– – 4 4 4 4 4 4MID ready compliance, EN50470-1/3, Annex B & Annex D Class C–PM5111– – – –PM5331 PM5341Power quality analysisTHD, thd, TDDb b b b b b b bHarmonics, individual (odd) up to15th 15th 31st 31st 31st 31st 31st 31stWaveform capture & sag/swell detection– – – – – – – –I/Os and relaysDigital inputs/ Digital output1DO 1DO 2DI/2DO 2DI/2DO 2DI/2DO 2DI/2DO 2DI/2DO 2DI/2DORelays– – – – – – 2 2Analog inputs– – – – – – – –Residual Current inputs– – – – – – – –Alarms and controlAlarms33 33 35 35 35 35 35 35Set point response time, seconds1 1 1 1 1 1 1 1Single and multi-condition alarms– –b b b b b bBoolean alarm logic– – – – – – – –Memory for data logging– – 256KB 256KB 256KB 256KB 256KB 256KBCommunicationsSerial ports with modbus protocol– 1 1 1 – – 1 –Ethernet port with Modbus TCP protocol– – – – 1 1 – 1BACnet/IP protocol– – – –b b–bEtherNet/IP protocol– – – – – – – –DNP3.0 over Ethernet– – – – – – – –Onboard web server with web pages– – – – – – – –Serial to Ethernet gateway– – – – – – – –Ref. number followed with METSE*PM5100 PM5110 PM5310 PM5310R (+4)PM5320 PM5320R (+4)PM5330 PM5340*See table below for complete commercial reference numbers(+4) PM5310R and PM5320R must be used with Schneider Electric’s “Quick Click” 3-in-1 LVCTsPM5000 seriesBASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS109Version: 1.0 - 30/05/2022PLSED310126EN_05
PM5000 series(+5) 2 Ethernet ports for daisy chain, one IP address.PM5000 series feature selectionPM5500 PM5600 PM5700PM5560 PM5563 PM5563RD PM5570 PM5580 PM5650 PM5660 PM5760InstallationFast installation, panel mount with integrated displayb– –b b b b bFast installation, DIN rail mountable–b b– – – – –AccuracyClass CL 0.2S CL 0.2S CL 0.2S CL 0.2S CL 0.2S CL 0.2S CL 0.2S CL 0.2SDisplayBacklit LCD, multilingual, bar graphs, 6 lines, 4 concurrent valuesb–b b b b b bPower and energy metering3-ph voltage, current, power, demand, energy, frequency, power factorb b b b b b b bMulti-tariff 8 8 8 8 8 8 8 8MID ready compliance, EN50470-1/3, Annex B & Annex D Class CPM5561– – – – –PM5661 PM5761Power quality analysisTHD, thd, TDDb b b b b b b bHarmonics, individual (odd) up to63rd63rd63rd63rd63rd63rd63rd63rdWaveform capture & sag/swell detection– – – – –8 cycles @ 128 samples/cycle–8 cycles @ 128 samples/cycleI/Os and relaysDigital inputs/ solid state Digital output4DI/2DO 4DI/2DO 4DI/2DO 2DI/2DO 4DI/2DO 4DI/2DO 2DI/2DO 2DI/2DORelays– – – – – – – –Analog inputs– – –2– – – –Residual Current inputs– – – – – – 2 2Alarms and controlAlarms 52 52 52 50 52 54 54 56Set point response time, seconds1 1 1 1 1 1 1 1Single and multi-condition alarmsb b b b b b b bBoolean alarm logicb b b b b b b bMemory for data logging 1.1 MB 1.1 MB 1.1 MB 1.1 MB 1.1 MB 1.1 MB 1.1 MB 1.1 MBCommunicationsSerial ports with modbus protocol1 1 1 1 1 1 1 1Ethernet port with Modbus TCP protocol2 (+5)2 (+5)2 (+5)2 (+5)2 (+5)2 (+5)2 (+5)2 (+5)BACnet/IP protocolb b b b b b b bEtherNet/IP protocolb b b b b b b bDNP3.0 over Ethernetb b b b b b b bOnboard web server with web pagesb b b b b b b bSerial to Ethernet gatewayb b b b b b b bRef. numbers with METSE*PM5560 PM5563 PM5563RD PM5570 PM5580 PM5650 PM5660 PM5760*See table below for complete commercial reference numbersBASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 30/05/2022PLSED310126EN_05110
PM5000 technical specicationsPM5100 PM5300 PM5500 PM5600 PM5700Use on LV and MV systemsbBasic metering with THD and min/max readingsbInstantaneous rms valuesCurrentAverage, per phase, neutral and ground (PM5500)bVoltageAverage, per phase L–L and L–N bFrequency Any available phasebReal, reactive, and apparent powerTotal and per phase Signed, Four QuadrantTrue Power Factor Average and per phase Signed, Four QuadrantDisplacement PF Average and per phase Signed, Four Quadrant% Unbalanced I, V L-N, V L-LbDirect monitoring of neutral current –b b bEnergy valuesAccumulated Active, Reactive and Apparent Energy Received/Delivered; Net and absolute; Time CountersDemand valueCurrent average Present, Last, Predicted, Peak, and Peak Date TimeActive power Present, Last, Predicted, Peak, and Peak Date TimeReactive power Present, Last, Predicted, Peak, and Peak Date TimeApparent power Present, Last, Predicted, Peak, and Peak Date TimePeak demand with timestamping D/T for current and three powersbDemand calculationSliding, xed and rolling block, thermal methodsbSynchronisation of the measurement window to input, communication command or internal clockbSettable Demand intervalsbDemand synchronization with pulse input –bOther measurementsI/O timerbOperating timerbLoad timerbAlarm counters and alarm logsbPower quality measurementsTHD, thd (Total Harmonic Distortion) I, V L-N, V L-L I, V L-N, V L-LTDD (Total Demand Distortion)bIndividual harmonics (odds) 15th (PM5110) 31st63rdNeutral Current metering with ground current calculation– –bWaveform capture and sag/swell detection – – –8 cycles @ 128 samples/cycleData recordingMin/max of instantaneous values, plus phase identication (+6)bAlarms with 1s timestamping (+6)bData logging2 xed parameters kWh and kVAh with congurable interval & duration (e.g. 2 parameters for minimum 60 days at 15–minute intervals)Up to 14 selectable parameters with congurable interval and duration (e.g. 6 parameters for minimum 90 days at 15–minute intervals)Min/max logb b bMaintenance, alarm and event logsb bCustomisable data logs –bRTC with battery back up 3 years (when meter is in Power OFF condition)Display resolution 5 digits for Energy and other parameters with auto scalingPreset Energy and Energy scaling Available in selected referencesPM5000 series (+6) Stored in non-volatile memoryBASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS111Version: 1.0 - 30/05/2022PLSED310126EN_05
PM5000 technical specificationsPM5100 PM5300 PM5500 PM5600 PM5700Inputs / Outputs / Mechanical RelaysDigital inputs –24 in PM5560, PM5563, PM5580, PM56502 in PM5570, PM5660, PM5760Digital outputs 1 (kWh only) 2 2 (Solid state)Form A Relay outputs –2–Analog inputs – – 2 for PM5570 – –Residual Current inputs – – 2 for PM5660 2 for PM5760Timestamp resolution in seconds1 1 1 1 1Whetting source – 24 V DC, 8 mA – – –Type of measurement: True rms on three-phase (3P, 3P + N) 64 samples per cycle 128 samples per cycleMeasurement accuracyIEC 61557-12PMD/[SD|SS]/K70/0.5 PMD/[SD|SS]/K70/0.2Active EnergyClass 0.5S as per IEC 62053-22/ Class 0.5 as per IEC 61557-12/ ± 0.5%Class 0.2S as per IEC 62053-22/ Class 0.2 as per IEC 61557-12/ ± 0.2%Reactive EnergyClass 2 as per IEC 62053-23/ Class 1.0 as per IEC 61557-12/ ± 1.0%Class 2 as per IEC 62053-23/ Class 1.0 as per IEC 61557-12/ ± 1.0%Active PowerClass 0.5 as per IEC 61557-12/ ± 0.5% Class 0.2 as per IEC 61557-12/ ± 0.2%Apparent PowerClass 0.5 as per IEC 61557-12/ ± 0.5% Class 0.5 as per IEC 61557-12/ ± 0.5%Reactive PowerClass 1.0 as per IEC 61557-12/ ± 1.0% Class 1.0 as per IEC 61557-12/ ± 1.0%Current, PhaseClass 0.5 as per IEC 61557-12/ ±0.5 % Class 0.2 as per IEC 61557-12/ ±0.15 %Voltage, L-NClass 0.5 as per IEC 61557-12/ ± 0.5 % Class 0.2 as per IEC 61557-12/ ± 0.1 %FrequencyClass 0.05 as per IEC 61557-12/ ±0.05 % Class 0.05 as per IEC 61557-12/ ±0.05 %Power FactorClass 0.5 as per IEC 61557-12/ ±0.005 count Class 0.5 as per IEC 61557-12/ ±0.005 countVoltage unbalance Class 5/ ±5% Class 2/ ±2%Voltage harmonics Class 5/ ±5% Class 2/ ±2%Voltage THD ClassClass 5/ ±5% Class 2/ ±2%Current harmonicsClass 5/ ±5% Class 2/ ±2%Current THD ClassClass 5/ ±5% Class 2/ ±2%MID Directive EN50470-1, EN50470-3Annex B and Annex D (Optional model references) Class CInput-voltage(up to 1.0 MV AC max, with voltage transformer)Nominal Measured Voltage range20 V L-N / 35 V L-L to 400 V L-N /690 V L-Labsolute range 35 V L-L to 760 V L-L20 V L-N / 20 V L-L to 400 V L-N /690 V L-Labsolute range 20 V L-L to 828 V L-LImpedance 5 MΩFrequency nominal 50 or 60 Hz ±5 % 50 or 60 Hz ±10 %Input-current(configurable for 1 or 5 A secondary CTs)I nominal 5 A –Measured Amps with over range Starting current: 5 mAOperating range: 50 mA to 8.5 AStarting current: 5 mA Operating range: 50 mA to 10 A (with Crest Factor)Withstand Continuous 20 A, 10 s/hr 50 A, 1 s/hr 500 AImpedance < 0.3 mΩ Frequency nominal 50 or 60 Hz ±5 % 50 or 60 Hz ±10 %Burden <0.026 VA at 8.5 AAC control powerOperating range100 - 277 V AC L-N / 415 V L-L +/-10 % CAT III 300V class per IEC 61010100-480 V AC ±10 %CAT III 600V class per IEC 61010Burden <5 W,11 VA at 415V L-L<5W/16.0 VA at 480 V ACFrequency 45 to 65 HzRide through time at maximum burden80 mS typical at 120V AC 100 mS typical at 230 V AC 100 mS typical at 415 V AC35 ms typical at 120 V L-N129 ms typical at 230 V L-NDC control powerOperating range 125–250 V DC ±20 % (100 to 300 V DC)Burden <4 W at 250 V DC typical 3.1 W at 125 V DC, max. 5 WRide-through time 50 mS typical at 125 V DC and maximum burdenLV DC control power20-60 V DC ±10 %CAT III Burden 4.1 W max.– –b PM5580– –PM5000 seriesBASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 30/05/2022PLSED310126EN_05112
PM5000 technical specificationsPM5100 PM5300 PM5500 PM5600 PM5700OutputsRelayoutputsMax output frequency–0.5 Hz maximum (1 s ON / 1 s OFF - min times)– – –Switching current, at resistive load–250 V AC at 8.0 Amps, 25 k cycles 30 V DC at 2.0 Amps, 75 k cycles30 V DC at 5.0 Amps, 12.5 k cycles– – –Isolation–2.5 kV rms– – –DigitaloutputsMax load voltage 40 V DC40 V AC / 60 V DC (PM5500 and PM 5650)30 V AC / 40 V DC (PM5660, PM5661, PM5760, PM5761)Max load current 20 mA 125 mA (Solid state)On Resistance 50 Ω max 8 ΩMeter constant from 1 to 9,999,999 pulses per k_h (kWh, kVAh, kVARh)Pulse width for Digital Output50 % duty cyclePulse frequency for Digital Output25 Hz max.Leakage current 0.3 micro Amps 1 micro AmpsIsolation 5 kV rms 2.5 kV rms for 60 sOptical outputsPulse width (LED) 200 msPulse frequency 2.5 kHz. max 2.5 kHz. max Meter constant from 1 to 9,999,999 pulses per k_h (kWh, kVAh, kVARh)Status InputsON Voltage–18.5 to 36 V DC 15 to 30 V AC / 15 to 60 V DC maxOFF Voltage–0 to 4 V DC 0 to 6 V AC / 0 to 6 V DCInput Resistance–110 k Ω 100 k ΩMaximum Frequency–2 Hz (T ON min = T OFF min = 250 ms)25 Hz (T ON min = T OFF min = 20 ms)Response Time–20 ms 10 msOpto Isolation–5 kV rms 2.5 kV rms for 60 sWhetting output–24 V DC/ 8 mA max-Input Burden–2 mA @24V DC2 mA @ 24 V AC/DC2.5 mA @ 60 V AC/DCAnalog inputs (PM5570)–4 - 20 mA DC (nominal),Accuracy: 1% of full-scale reading,Impedance < 20 Ω,Operating voltage: 24 V DC max–Residual Current inputs (PM5660, PM5661, PM5760, PM5761)Type A as per IEC 62020– 5 uA to 1200 uA (nominal), 1500 uA max (continuous), Input type: AC 45 to 65 Hz,Burden: 150 Ω, Default toroid: 1000 turnsMechanical characteristics Product weight 380 g 430 g 450 g 450 g 450 gIP degree of protection (IEC 60529) IP54 front display, IP30 rear side (IP65 front side with Optional accessory kit METSEIP65OP96X96FF)Dimensions W x H x D [protrusion from cabinet] 96 x 96 x 72 mm (77 mm for PM5500) (depth of meter from housing mounting flange) [13 mm]Mounting position VerticalPanel thickness 6 mm maximumLVCT (+7) inputs for PM5310R and PM5320R - Nominal voltage of 0.333VMeasurement range - 0.00333V - 0.4V - - -PM5000 series (+7) PM5310R and PM5320R must be used with Schneider Electric’s “Quick Click” 3-in-1 LVCTsBASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS113Version: 1.0 - 30/05/2022PLSED310126EN_05
PM5000 seriesPM5000 technical specificationsPM5100 PM5300 PM5500 PM5600 PM5700Environmental characteristics Operating temperatureOperating temperature -25 °C to 70 °CDisplay (reduced display performance at -25 º C)-25 °C to 70 °CStorage temperature -40 °C to 85 °CHumidity range 5 to 95 % RH at 50 °C (non-condensing)Pollution degree 2Altitude 2000 m CAT III / 3000 m CAT II 3000 m max. CAT IIIMission profile / Life span >15 yearsElectromagnetic compatibilityHarmonic current emissions– –IEC 61000-3-2 Flicker emissions– –IEC 61000-3-3Electrostatic discharge IEC 61000-4-2Immunity to radiated fields IEC 61000-4-3Immunity to fast transients IEC 61000-4-4 Immunity to surge IEC 61000-4-5 Conducted immunity 150 kHz to 80 MHz IEC 61000-4-6 Immunity to magnetic fields IEC 61000-4-8 Immunity to voltage dips IEC 61000-4-11 Immunity to damped oscillatory waves– –IEC 61000-4-12Radiated and conducted emissions FCC part 15, EN 55022 Class BSafetyEurope CE, as per IEC 61010-1 Ed. 3, IEC 62052-11 & IEC 61557-12U.S. and Canada cULus as per UL 61010-1 (Edition 3)Measurement category (Voltage & Current inputs) CAT III up to 400 V L-N / 690 V L-LDielectric As per IEC/UL 61010-1 (Edition 3)Protective Class II, Double insulated for user accessible partsCommunicationRS-485 port Modbus RTU, Modbus ASCII (7 or 8 bit), JBUS2-Wire, 9600,19200 or 38400 baud, Parity - Even, Odd, None, 1 stop bit if parity Odd or Even, 2 stop bits if None; (Optional in PM51x and PM53x)Ethernet port: 10/100 Mbps; Modbus TCP/IP–1 Optional 2 (daisy chain only, 1 IP address)Native Ethernet/IP & DNP3.0 over Ethernet– –Yes Yes YesFirmware and language file update Meter firmware update via the communication portsIsolation 2.5 kVrms, double insulatedHuman machine interfaceDisplay type Monochrome Graphics LCDResolution 128 x 128 pixelsBacklight White LEDViewable area (W x H) 67 x 62.5 mmKeypad 4-buttonIndicator Heartbeat / Communication activity Green LEDEnergy pulse output / Active alarm (configurable) Optical, amber LEDWavelength 590 to 635 nmMaximum pulse rate 2.5 kHzBASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 30/05/2022PLSED310126EN_05114
Comm. ref numbers DescriptionMETSEPM5100 Power Meter, 600V AC L-L/ 5A or 1A input, 415V AC L-L or 250V DC control power, Cl 0.5S, 15th harmonic, 1DOMETSEPM5110 Power Meter, 600V AC L-L/ 5A or 1A input, 415V AC L-L or 250V DC control power, Cl 0.5S, 15th harmonic, 1DO, RS-485METSEPM5111 Power Meter, 600V AC L-L/ 5A or 1A input, 415V AC L-L or 250V DC control power, Cl 0.5S, 15th harmonic, 1DO, RS-485, MIDMETSEPM5310 Power Meter, 600V AC L-L/ 5A or 1A input, 415V AC L-L or 250V DC control power, Cl 0.5S, 31st harmonic, 256 kB, 2DI/2DO, RS-485METSEPM5310R Power Meter, 600V AC L-L/ RJ45 LVCT input, 415V AC L-L or 250V DC control power, Cl 0.5S, 31st harmonic, 256 kB, 2DI/2DO, RS-485METSEPM5320 Power Meter, 600V AC L-L/ 5A or 1A input, 415V AC L-L or 250V DC control power, Cl 0.5S, 31st harmonic, 256 kB, 2DI/2DO, EthernetMETSEPM5320R Power Meter, 600V AC L-L/ RJ45 LVCT input, 415V AC L-L or 250V DC control power, Cl 0.5S, 31st harmonic, 256 kB, 2DI/2DO, EthernetMETSEPM5330 Power Meter, 600V AC L-L/ 5A or 1A input, 415V AC L-L or 250V DC control power, Cl 0.5S, 31st harmonic, 256 kB, 2DI/2DO/2-Relay, RS-485METSEPM5331 Power Meter, 600V AC L-L/ 5A or 1A input, 415V AC L-L or 250V DC control power, Cl 0.5S, 31st harmonic, 256 kB, 2DI/2DO/2-Relay, RS-485, MIDMETSEPM5340Power Meter, 600V AC L-L/ 5A or 1A input, 415V AC L-L or 250V DC control power, Cl 0.5S, 31st harmonic, 256 kB, 2DI/2DO/2-Relay, EthernetMETSEPM5341Power Meter, 600V AC L-L/ 5A or 1A input, 415V AC L-L or 250V DC control power, Cl 0.5S, 31st harmonic, 256 kB, 2DI/2DO/2-Relay, Ethernet, MIDMETSEPM5560Power Meter, 690V AC L-L/ 5A or 1A input, 480V AC L-L or 250V DC control power, Cl 0.2S, 63rd harmonic, 1.1 MB, 4DI/2-DO, RS-485, EthernetMETSEPM5561Power Meter, 690V AC L-L/ 5A or 1A input, 480V AC L-L or 250V DC control power, Cl 0.2S, 63rd harmonic, 1.1 MB, 4DI/2-DO, RS-485, Ethernet, MIDMETSEPM5562Power Meter, 690V AC L-L/ 5A or 1A input, 480V AC L-L or 250V DC control power, Cl 0.2S, 63rd harmonic, 1.1 MB, 4DI/2-DO, RS-485, Ethernet, RMI CAN approved, Hwardware lockableMETSEPM5562MCPower Meter, 690V AC L-L/ 5A or 1A input, 480V AC L-L or 250V DC control power, Cl 0.2S, 63rd harmonic, 1.1 MB, 4DI/2-DO, RS-485, Ethernet, RMI CAN approved, Factory sealedMETSEPM5563Power Meter, 690V AC L-L/ 5A or 1A input, 480V AC L-L or 250V DC control power, Cl 0.2S, 63rd harmonic, 1.1 MB, 4DI/2-DO, RS-485, Ethernet, DIN mount, No displayMETSEPM5563RDPower Meter, 690V AC L-L/ 5A or 1A input, 480V AC L-L or 250V DC control power, Cl 0.2S, 63rd harmonic, 1.1 MB, 4DI/2-DO, RS-485, Ethernet, DIN mount, Remote displayMETSEPM5570 Power Meter, 690V AC L-L/ 5A or 1A input, 480V AC L-L or 250V DC control power, Cl 0.2S, 63rd harmonic, 1.1 MB, 2DI/2AI/2-DO, RS-485, EthernetMETSEPM5580 Power Meter, 690V AC L-L/ 5A or 1A input, 24 to 64V DC control power, Cl 0.2S, 63rd harmonic, 1.1 MB, 4DI/2-DO, RS-485, EthernetMETSEPM5650Power Meter, 690V AC L-L/ 5A or 1A input, 480V AC L-L or 250V DC control power, Cl 0.2S, 63rd harmonic, 1.1 MB, 4DI/2-DO, RS-485, Ethernet, Wave Form Capture and Sag/swellMETSEPM5660Power Meter, 690V AC L-L/ 5A or 1A input, 480V AC L-L or 250V DC control power, Cl 0.2S, 63rd harmonic, 1.1 MB, 2DI/2-DO, RS-485, Ethernet, Residual Current MonitorMETSEPM5661Power Meter, 690V AC L-L/ 5A or 1A input, 480V AC L-L or 250V DC control power, Cl 0.2S, 63rd harmonic, 1.1 MB, 2DI/2-DO, RS-485, Ethernet, Residual Current Monitor, MIDMETSEPM5760Power Meter, 690V AC L-L/ 5A or 1A input, 480V AC L-L or 250V DC control power, Cl 0.2S, 63rd harmonic, 1.1 MB, 2DI/2-DO, RS-485, Ethernet, Wave Form Capture and Sag/swell, Residual current monitorMETSEPM5761Power Meter, 690V AC L-L/ 5A or 1A input, 480V AC L-L or 250V DC control power, Cl 0.2S, 63rd harmonic, 1.1 MB, 2DI/2-DO, RS-485, Ethernet, Wave Form Capture and Sag/swell, Residual current monitor, MIDResidual Current Monitoring Toroids (Vigirex) - Closed Toroids, A Type50437 TA30 - closed toroid A type, for RCM enabled power meters, 30 mm inner diameter, rated current 65 Amps, 1000 turns50438 PA50 - closed toroid A type, for RCM enabled power meters, 50 mm inner diameter, rated current 85 Amps, 1000 turns50439 IA80 - closed toroid A type, for RCM enabled power meters, 80 mm inner diameter, rated current 160 Amps, 1000 turns50440 MA120 - closed toroid A type, for RCM enabled power meters, 120 mm inner diameter, rated current 250 Amps, 1000 turns50441 SA200 - closed toroid A type, for RCM enabled power meters, 200 mm inner diameter, rated current 400 Amps, 1000 turns50442 GA300 - closed toroid A type, for RCM enabled power meters, 300 mm inner diameter, rated current 630 Amps, 1000 turnsAccessories for Closed Toroids56055 Magnetic ring/ Iron screen accessory for TA30 toroid sensor56056 Magnetic ring/ Iron screen accessory for PA50 toroid sensor56057 Magnetic ring/ Iron screen accessory for IA80 toroid sensor56058 Magnetic ring/ Iron screen accessory for MA120 toroid sensorResidual Current Monitoring Toroids (Vigirex) - Split Toroids, OA Type50420 TOA80 - split toroid OA type, 80 mm inner diameter, rated current 160 Amps, 1000 turns50421 TOA120 - split toroid OA type, 120 mm inner diameter, rated current 250 Amps, 1000 turns56053 L1 type - rectangular sensor, width 280 x height 115 mm, rated current 1600 Amps, 1000 turns56054 L2 type - rectangular sensor, width 470 x height 160 mm, rated current 3200 Amps, 1000 turnsPM5000 seriesBASIC MULTI-FUNCTION METERING COMMERCIAL REFERENCE NUMBERS115Version: 1.0 - 30/05/2022PLSED310126EN_05
Please contact your Schneider Electric representative for complete ordering information.Comm. ref numbers Description0.333V (1/3 Volts), 3-in-1 CTs with RJ45 connetors for PM53x0R LVCT enabled power meterMETSECTV25006LVCT Solid core 3 in 1 with RJ45 cable, 25 mm phase center, 60 Amps, 0.333V outputMETSECTV25010LVCT Solid core 3 in 1 with RJ45 cable, 25 mm phase center, 100 Amps, 0.333V outputMETSECTV25013LVCT Solid core 3 in 1 with RJ45 cable, 25 mm phase center, 125 Amps, 0.333V outputMETSECTV25016LVCT Solid core 3 in 1 with RJ45 cable, 25 mm phase center, 160 Amps, 0.333V outputMETSECTV35006LVCT Solid core 3 in 1 with RJ45 cable, 35 mm phase center, 60 Amps, 0.333V outputMETSECTV35010LVCT Solid core 3 in 1 with RJ45 cable, 35 mm phase center, 100 Amps, 0.333V outputMETSECTV35012LVCT Solid core 3 in 1 with RJ45 cable, 35 mm phase center, 120 Amps, 0.333V outputMETSECTV35013LVCT Solid core 3 in 1 with RJ45 cable, 35 mm phase center, 125 Amps, 0.333V outputMETSECTV35015LVCT Solid core 3 in 1 with RJ45 cable, 35 mm phase center, 150 Amps, 0.333V outputMETSECTV35016LVCT Solid core 3 in 1 with RJ45 cable, 35 mm phase center, 160 Amps, 0.333V outputMETSECTV35020LVCT Solid core 3 in 1 with RJ45 cable, 35 mm phase center, 200 Amps, 0.333V outputMETSECTV35025LVCT Solid core 3 in 1 with RJ45 cable, 35 mm phase center, 250 Amps, 0.333V outputMETSECTV45025LVCT Solid core 3 in 1 with RJ45 cable, 45 mm phase center, 250 Amps, 0.333V outputMETSECTV45030LVCT Solid core 3 in 1 with RJ45 cable, 45 mm phase center, 300 Amps, 0.333V outputMETSECTV45040LVCT Solid core 3 in 1 with RJ45 cable, 45 mm phase center, 400 Amps, 0.333V outputMETSECTV45050LVCT Solid core 3 in 1 with RJ45 cable, 45 mm phase center, 500 Amps, 0.333V outputMETSECTV45060LVCT Solid core 3 in 1 with RJ45 cable, 45 mm phase center, 600 Amps, 0.333V outputMETSECTV45063LVCT Solid core 3 in 1 with RJ45 cable, 45 mm phase center, 630 Amps, 0.333V outputMETSECTV29006LVCT Solid core 3 in 1 with RJ45 cable, 29 mm phase center, 60 Amps, 0.333V outputMETSECTV29010LVCT Solid core 3 in 1 with RJ45 cable, 29 mm phase center, 100 Amps, 0.333V outputMETSECTV29012LVCT Solid core 3 in 1 with RJ45 cable, 29 mm phase center, 120 Amps, 0.333V outputMETSECTV29013LVCT Solid core 3 in 1 with RJ45 cable, 29 mm phase center, 125 Amps, 0.333V outputMETSECTV29015LVCT Solid core 3 in 1 with RJ45 cable, 29 mm phase center, 150 Amps, 0.333V outputMETSECTV29016LVCT Solid core 3 in 1 with RJ45 cable, 29 mm phase center, 160 Amps, 0.333V outputMETSECTV29020LVCT Solid core 3 in 1 with RJ45 cable, 29 mm phase center, 200 Amps, 0.333V outputMETSECTV70080LVCT Solid core 3 in 1 with RJ45 cable, 70 mm phase center, 800 Amps, 0.333V outputMETSECTV70100LVCT Solid core 3 in 1 with RJ45 cable, 70 mm phase center, 1000 Amps, 0.333V outputMETSECTV70125LVCT Solid core 3 in 1 with RJ45 cable, 70 mm phase center, 1250 Amps, 0.333V outputCablesMETSEPM5CAB03RJ25 cable assembly for interfacing PM5563 meter and PM5RD remote display with 0.3 meter cable lengthMETSEPM5CAB1RJ25 cable assembly for interfacing PM5563 meter and PM5RD remote display with 1.0 meter cable lengthMETSEPM5CAB10RJ25 cable assembly for interfacing PM5563 meter and PM5RD remote display with 10 meter cable lengthMETSEPM5CAB3RJ25 cable assembly for interfacing PM5563 meter and PM5RD remote display with 3 meter cable lengthMETSEPM5CAB4RJ25 cable assembly for interfacing PM5563 meter and PM5RD remote display with 4 meter cable lengthOther related productsMETSEPM5RDRemote display unit for PM5563 power meter supplied with mounting bracket, gasket, anti-rotation pin and RJ25 cable METSEPMCABxyMETSEPM51HKHardware kit for PM51xx comprises 2 retainer clips and spare connectors for - Voltage in, Control power in, Digital IO & RS-485METSEPM53HKHardware kit for PM51xx comprises 2 retainer clips and spare connectors for - Voltage in, Control power in, Digital IO, Relay & RS-485METSEPM51_3RSKRevenue sealing kit for PM51XX & PM53XXMETSEPM55RSKRevenue sealing kit for PM55XXMETSEPM55HKHardware kit for PM55xxMETSEPM5CAB3Remote Display cablePM5300R series commercial reference numbersBASIC MULTI-FUNCTION METERING COMMERCIAL REFERENCE NUMBERSVersion: 1.0 - 30/05/2022PLSED310126EN_05116
PM5000 meter parts Please see the appropriate Installation Guide for accurate and complete information on the installation of this product.PM5100 / PM5300 meter partsPM5100 / PM5300 PM5500 / PM5600PM5500 / PM5600 meter partsPM5500PM5000 Series meter ush mountingPM5000 series meter dimensionsPM5000 series overviewPB111276mPB111279_mPB111278PB111277PB111291 PB111289PB111279APM5000PM5000 seriesMenu selection buttons LED indicators Navigation or menu selectionsMaintenance and alarm notification area ABCDRelay output (PM5300 only) Voltage inputs Control power Current inputs Status inputs/digital outputsCommunications port: Ethernet (PM5300 only) or RS-485)EFGHIJVoltage inputs RS-485 comms Digital inputs Current inputs Digital outputs Ethernet ports Control power EFGHIJKBASIC MULTI-FUNCTION METERING DIMENSIONS AND CONNECTIONVersion: 1.0 - 30/05/2022PLSED310126EN_05117
The PowerLogic™ PM5350 series power meters are the new benchmark in aordable, precision metering. The PowerLogic™ PM5350, PM5350IB, PM5350PB, and PM5350P power meters oer all the measurement capabilities required to monitor an electrical installation in a space-ecient, single 96 x 96 mm unit with small depth. DNC certies for marine applications.PowerLogic™ PM5350 seriesApplications• Panel instrumentation.• Cost allocation or energy management• Electrical installation remote monitoring• Sophisticated alarming• Circuit beaker monitoring and controlPB117510METSEPM5350PBASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 30/05/2022PLSED310126EN_05118
The solution forMarkets that can benet from a solution that includes PowerLogic™ PM5350 series meters:• Buildings• Industry• Healthcare• Data Centre and networks• InfrastructurePower management solutionsSchneider Electric provides innovative power management solutions to increase your energy eciency and cost savings, maximise electrical network reliability and availability, and optimise electrical asset performance. Competitive advantages• Easy to install and operate• Easy for circuit breaker monitoring and control• Power quality analysis• Load management combined with alarm and timestamping• High performance and accuracy• Multi-tari capabilities• Individual harmonics up to 31stConformity of standards• IEC 62053-22• IEC 61557-12• IEC 62053-23• IEC/UL 61010-1• IEC 61326-1• UL 61010-1• IEC 61000-3-3• FCC part 15 Class A• DNV GL certiedBenetsSystem integrators’ benet• Ease of integration• Ease of setup• Cost eectivenessPanel builders’ benet• Ease of installation• Cost eectiveness• Aesthetically pleasing• Simplied orderingEnd users’ benet• Ease of use• Precision metering & sub-billing• Billing exibility• Comprehensive, consistent and superior performanceBASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS119Version: 1.0 - 30/05/2022PLSED310126EN_05
The PowerLogic™ PM5350 series power meter soffer electrical installation measurement capabilities in a single 96 x 96 mm unit. Three-phases and neutral can be monitored simultaneously using a bright, anti-glare display with large characters and backlighting. Menus are intuitive and the meter supports English, Chinese, Hebrew, and Spanish languages. Its compact size and high performance make the PowerLogic™ PM5350 sereis suitable for many applications.• Applications– Panel instrumentation.– Cost allocation or energy management.– Electrical installation remote monitoring.– Alarming with under/over, digital status, control power interruption, meterreset, self diagnostic issue.– Circuit Breaker monitoring and control with relay outputs and whetteddigital inputs.• Main characteristics– Easy to install– Mounts using two clips, no tools required. Ultra compact meterwith 44 mm depth connectable up to 480 V L-L without voltagetransformers for installations compliant with category III, as perIEC 61010-1. See specification table for UL voltage limits.– Easy to operate– Intuitive navigation with self-guided, language selectable menus,six lines, four concurrent values. Two LEDs help confirm normaloperation.– Easy circuit breaker monitoring and control– Two relay outputs (high performance) to command most circuitbreaker coils directly. Monitored switches can be wired directlywithout external power supply.– System status at a glance– Bright, anti-glare, backlit display plus two LEDs; orange for energypulse or alarm and green for heartbeat/communications indication.– IEC 62053-22 class 0.5S accuracy for active energy– Accurate energy measurement for cost allocation.– Power Quality analysis– The PM5350P offers THD and TDD measurements as standard.Total Demand Distortion is based on a point of common coupling(PCC), which is a common point that each user receives powerfrom the power source. The TDD compares the contribution ofharmonics versus the maximum demand load. In addition, it hasindividual harmonics (odd) measurement up to 31st harmonics.These types of power quality parameters help to identify the sourceof harmonics that can harm transformers, capacitors, generators,motors and electronic equipment.• Load management– Peak demands with Timestamping are provided. Predicted demandvalues can be used in basic load shedding applications.Alarming with timestamping– Over 30 alarm conditions, such as under/over conditions, digitalinput changes, and phase unbalance inform you of events. A time-stamped log maintains a record of the last 40 alarm events.– Load timer setpoint adjustable to monitor and advise maintenancerequirements.– Performance Standard Meets IEC 61557-12 PMD/Sx/K70/0.5.PM5350 seriesCommercial reference numberDescriptionMETSEPM5350RS-485 Modbus, THD, 4DI, 2RelayMETSEPM5350IBRS-485, 4DI/2Relay, Multi-level alarm, UL480V, 4DI/2RelayMETSEPM5350PBRS-485, 4DI/2Relay, Multi-level alarm, UL300V, 4DI/2Relay METSEPM5350PRS-485 Modbus, THD, 31st Individual harmonics, Multi-tari, 4DI/2Relay Front display of PowerLogic™ PM5350P front displayRear view of PowerLogic™ PM5350PPB117511PB117512BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 30/05/2022PLSED310126EN_05120
Feature guidePM5350P PM5350 PM5350IB PM5350PBGeneralUse on LV and MV systemsbBasic metering with THD and min/max readingsbInstantaneous rms valuesCurrent Total, Phases and neutralbVoltage Total, Ph-Ph and Ph-NbFrequencybReal, reactive, and apparent powerTotal and per phaseSignedTrue Power Factor Total and per phaseSigned, Four QuadrantDisplacement PF Total and per phaseSigned, Four QuadrantUnbalanced I, VL-N, VL-LbAccumulated Active, Reactive and Apparent EnergyStored in non-volatile memoryReceived/Delivered; Net and absolute;Demand valuesCurrent average Present, Last, Predicted, Peak, & Peak Date TimebActive power Present, Last, Predicted, Peak, & Peak Date TimebReactive power Present, Last, Predicted, Peak, & Peak Date TimebApparent power Present, Last, Predicted, Peak, & Peak Date TimebMulti-tari 16 tarisPeak demand with timestamping D/T for current & powersbDemand calculation Sliding, xed and rolling block, thermalbSynchronization of the measurement windowbOther measurementsI/O timerbOperating timerbActive load timerbAlarm countersbPower quality measurementsTHD, thd (Total Harmonic Distortion) I, V L-N, V L-LTDD, thd (Total Demand Distortion)bHarmonics Individual (Odd) 31stData recordingMin/max of instantaneous values, plus phase identicationbAlarms with 1s timestampingStandard 29; Unary 4; Digital 4Alarms stored in non-volatile memory40 eventsInputs/OutputsDigital inputs 4 (DI1, DI2, DI3, DI4)Digital outputs2 relay outputs (DO1, DO2) DisplayWhite backlit LCD display, 6 lines, 4 concurrent valuesbIEC or IEEE visualization modebCommunicationModbus RTU, Modbus ASCII, Jbus ProtocolbFirmware update via RS-485 serial port (DLF3000 via the Schneider Electric website: www.se.com)bPM5350 seriesBASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS121Version: 1.0 - 30/05/2022PLSED310126EN_05
Electrical characteristicsPM5350 PM5350P PM5350PB/IBType of measurementTrue rms measurement in 1P, 2P, 3P network, supports 13 wiring schemes.32 samples per cycle, zero blindb31stbMeasurement accuracyCurrent, Phase(1)±0.30 % b0.2% (Avg A)bVoltage, L-N (1)±0.30 % b0.2% (Avg A)bPower Factor (1)±0.005 bPower, Phase(2)IEC 61557-12 Class 0.5; For 5 A nominal CT bFrequency (1)±0.05 % bReal Energy(3)IEC 62053-22 Class 0.5SIEC 61557-12 Class 0.5bReactive Energy(4)IEC 62053-23 Class 2IEC 61557-12 Class 2bData update rate 1 second nominal (50/60 cycles) bInput-voltage VT primary1.0 MV AC max, starting voltage depends on VT ratiobU nom277 V L-NbMeasured voltage with overrange & Crest FactorIEC: 20 to 480 V AC L-L; 20 to 277 V AC L-N, CAT III IEC: 20 to 690 V AC L-L; 20 to 400 V AC L-N, CAT II UL: 20 to 300 V AC L-L, CAT IIIbb and UL: 20 to 480 V AC L-LPermanent overload 700 V AC L-L, 404 V AC L-N bImpedance 10 MWbBurden 0.2 VA at 240 V AC L-NbFrequency range 45 to 70 Hzb45 to 65 HzbInput-currentCT ratings Secondary 1 A, 5 A nominal bMeasured voltage with overrange & crest factor5 mA to 9 AbWithstandContinuous 20 A,10 sec/hr 50 A,1 sec/hr 500 AbImpedance < 0.3 mW bFrequency range 45 to 70 HzbBurden < 0.024 VA at 9 AbAC control powerOperating range 85 - 265 V ACbBurden At 120 V AC, 4.1 VA/ 1.5 W typicalAt 230 V AC, 6.3 VA/ 2.0 W typicalAt 265 V AC, 9.6 VA/ 3.5 W typical6.7 VA / 2.7 W 8.6 VA / 2.9 W 11.9 VA / 3.5 W7 VA / 4 W 9 VA / 5 W 11.9 VA / 5 W6.7 VA / 2.7 W 8.6 VA / 2.9 W 11.9 VA / 3.5 W Frequency 45 to 65 HzbRide-through time Typical at 120 V AC and with maximum burden Typical at 230 V AC and with maximum burden100 mS 400 mS 40 mS 250 mS100 mS 400 mSDC control powerOperating range 100 to 300 V DCbBurden Typical/ Maximum at 125 V DCTypical/ Maximum at 250 V DCTypical Maximum at 300 V DC1.4 W / 2.6 W 1.8 W / 2.7 W 3.8 W max 4 W max5 W max5 W max1.4 W / 2.6 W 1.8 W / 2.7 W 3.8 W maxRide-through time Typical at 125 V DC and with maximum burden 50 mS 30 mS 50 mSReal time clock Battery backup 30 seconds ride-throughb3 years backup without control powerbDigital output Number/Type 2 - Mechanical RelaysbOutput frequency 0.5 Hz maximum (1 second ON / 1 second OFF - minimum times)bSwitching Current 30 V DC, 5 A250 V AC, 8 A Cos φ = 1250 V AC, 6 A Cos φ = 0.4bIsolation 2.5 kVrmsbStatus Digital InputsVoltage ratings ON 18.5 to 36 V DC, OFF 0 to 4 V DCbInput Resistance 110 k WbMaximum Frequency 2 Hz (T ON min = T OFF min = 250 ms)bResponse Time 10 msbIsolation 2.5 kVrmsbWhetting output Nominal voltage 24 V DCbAllowable load 4 mAbIsolation 2.5 kVrmsbPM5350 series(1) Measurements taken from 45 Hz to 65 Hz, 0.5 A to 9 A, 57 V to 347 V & 0.5 ind to 0.5 cap power factor with a sinusoidal wave.(2) Active power: ±0.5 % from 0.25 A to 9.0 A at Cos φ = 1, ±0.6 % from 0.50 A to 9.0 A at Cos φ = 0.5 (ind or cap)(3) Real/active Energy: ±0.5 % from 0.25 A to 9.0 A at Cos φ = 1, ±0.6 % from 0.50 A to 9.0 A at Cos φ = 0.5 (ind or cap) IEC 61557-12 Class 0.5(4) Reactive energy: ±2.0 % from 0.25 A to 9.0 A at Sin φ = 1±2.5 % from 0BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 30/05/2022PLSED310126EN_05122
PE86279PE86274Rear of meter - open Rear view retainers - installationPM5350 / PM5350P seriesPE86275For detailed installation instructions see the product's Installation Guide.Rear view retainers - usersPM5350 / PM5350P meter partsA Retainer clips.B Control power supply connector.C Voltage inputs.D Digital outputs.E RS-485 port (COM1).F Digital input.G Optical revenue switch.H Current inputs.PB113626PB113626 For detailed installation instructions see the product’s Installation Guide.BASIC MULTI-FUNCTION METERING DIMENSIONS AND CONNECTIONVersion: 1.0 - 30/05/2022PLSED310126EN_05123
Dimensions PM5350IBDimensions PM5350PBPM5350IB/PB seriesPB113626PB113626PM5350IBPB113626PB113626A Control powerB Voltage inputsC Current inputsD Digital inputsE Whetting voltage source (for digital inputs)F RS-485 communicationsG Digital outputsH Retainer clipsParts of PM5350IB and PM5350PB (rear panel door removed)PM5350PBPM5350IBPM5350PB For detailed installation instructions see the product’s Installation Guide.BASIC MULTI-FUNCTION METERING DIMENSIONS AND CONNECTIONVersion: 1.0 - 30/05/2022PLSED310126EN_05124
The EcoStruxure™ Panel Server is the next generation of gateway, providing a seamless connection of wired or unwired smart IoT devices to your edge control software or advisor. It is a foundational enabler for Schneider Electric EcoStruxure™ solutions.EcoStruxure™ Panel Server Electrical safetyPanel Server is an integral part of Schneider Electric’s continuous thermal monitoring application, helping reduce risk of electrical fires, increase people and assets protection. Implement the thermal monitoring of your electrical panel by connecting thermal and heat sensors to your Panel Server.Power availabilityElectrical distribution monitoring and power event analysis help avoid unplanned downtime caused by electrical failure. Panel server collects real-time data and alarms, presenting information through embedded webpages, making it available to edge control software or advisor for electrical system diagnostics. Use embedded webpages for first-level monitoring or monitor from your edge control.Optimize energy efficiencyImprove your facility’s energy efficiency and reduce energy consumption with energy usage analysis and performance tracking. Panel Server collects and shares energy data to help achieve your energy conservation initiatives. It is certified as part of an energy data management system according to ISO 50001, 50002, 50006.CybersecurityGuarding your electrical assets and systems against cyber attacks is vital. Panel server is an IEC 62443 compliant device and is central to the IEC 62443-3-3 SL1 certified EcoStruxure™ Power system. Use Cybersecurity Admin Expert to manage user accounts, define your cybersecurity policy and retrieve security logs.DB410983IoT for an intelligent power networkEcoStruxure™ Panel Server gives you access to the information you need to protect, maximize and optimize your power system. Help keep people and assets saferMaximize power availabilityOptimize energy efficiency@Improve cybersecurityECOSTRUXURE™ PANEL SERVER FUNCTIONS AND CHARACTERISTICS125Version: 1.0 - 30/05/2022PLSED310126EN_06
All-in-one gateway• Separates your OT network from your IT network• Wireless data concentrator• Modbus RS-485 to Modbus TCP• Supports multiple Ethernet connections forserving information to edge control software andcloud applicationsSimple commissioning• EcoStruxure™ Power Commission software• Device auto discovery• Generation of acceptance reports to validategateway configuration• Commission via Bluetooth® or WiFiIntuitive operation• User-friendly webpages offer first-levelmonitoring• Contextualized data and operational insights• Simple alarm setup for email notification• Standardized IEC 62974-1 compliant dataloggerand energy serverArchitecture overviewSchneider Electric cloud servicesGas meterGas meterWater meterWater metersEnergy metersEnergy and Power meters Circuit breakersPowerTag EnergyCircuit breakersPower metersProtection relays Ethernet or WiFi LAN Modbus Serial Line Analog/Digital IOs Wireless devicesEcoStruxure™ Panel Server webpagesInternetEthernet or WiFi LANEthernet / Modbus TCPCellularPower Monitoring Expert or third-party edge controlsEcoStruxure™ Panel ServerPowerTag ControlSensors Acti9 ActiveECOSTRUXURE™ PANEL SERVER FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 30/05/2022PLSED310126EN_06126
Functions• Optimized gateway to retrieve data your wireless devices.• Connect to your monitoring and control software such asEcoStruxure™ Power• Monitoring Expert, EcoStruxure™ Power Operation or to yourBuilding Management System.• Connect to Schneider cloud applications such as Facility Expertor Asset Advisor.• Ease of commissioning with EcoStruxure™ Power Commissionsoftware, enabling device plug-and-play and auto-discoveryfeatures.• Ease of operation with user friendly embedded webpages, anddata contextualization for more relevant analytics.Main features• Power Supply 110…277 V AC/DC• Designed to match with electrical switchboard environment(temperature, humidity electromagnetic compatibility)• One Ethernet 10Base-T/100Base-T port• Wi-Fi• Bluetooth communication for commissioning• IEEE 802.15.4 wireless communication• Modbus TCP/IP server• Support of HTTPS, NTP, SNTP, DHCP client with proxymanagement• Wireless devices concentrator to Modbus/TCP• Designed through a Secured Development Life Cycle inaccordance to IEC 62443-4-1• Commissioning through EcoStruxure™ Power Commission orthrough Embedded Web-Pages• Speed-up commissioning through device list import andconfiguration export to the monitoring software• Fully integrated in Cybersecurity Admin Expert tool to facilitatethe management of cybersecurity in your electrical network’s(User Management with Role Base Access and other securityfeatures such as enabling/disabling communication means).• Embedded web server for real-time measurement visualization,power consumption by usage• Customizable alarm with alarm log• Alarms can be viewed in the web-pages and notified by e-maileLISTEDCUSStandards & certifications• IEC 61010-1 Ed.2010• UL 61010-1 Ed.2012• IEC 61974• IEC 62443Comm. Reference DescriptionPAS400 Panel Server Entry 110..277 V AC/DCDB410978Panel Server Entry - Front ISO viewPanel Server Entry ECOSTRUXURE™ PANEL SERVER FUNCTIONS AND CHARACTERISTICS127Version: 1.0 - 30/05/2022PLSED310126EN_06
(+1) Consult the User Manual or other documentations to check the limit applicable to your wireless device.(+2) Lower limits may apply depending the firmware version, consult the User Manual, Release Notes or other documentations.Panel Server Entry Panel Server Entry technical specificationTechnical data EcoStruxure™ Panel Server EntryCommercial Reference PAS400Power SupplyVoltage 110-277 V AC/DCTolerance ± 10%Frequency 45-65 HzMaximum consumption 3 W, 10 VAEthernet & Wi-FiEthernet 10/100base TNumber of Ports Single RJ45 PortPoE 802.3af & 802.3at Class 0 N.A.Wi-Fi Supported Frequency 2.4 & 5 GHzTCP/IP YesIP V4 / IP V6 YesDPWS Ye sDHCP Client YesServer (Separate Nework) NoModbus/TCP Server Max. number of client connection 64 (+2)Modbus/TCP Client Max. number of TCP/Modbus devices N.A.Schneider Cloud Services YesHTTPS Ye sExternal Wi-Fi/Bluetooth Antenna N.A.Wireless Devices (IEEE 802.15.4)Number of devices Total 20 devicesPowerTag Energy & Ambient (+1)20 devicesOther type of devices (+1)20 devicesExternal IEEE 802.15.4 Antenna NoSerial PortsModbus RS-485 Master Max. number of devices w/o repeater N.A.Max. number of devices with repeater N.A.Maximum Length N.A.Baudrate N.A.FunctionalityData Buffering for cloud applications 1 monthData Logger and Web-Server Data Logging NoEvent logging Yes (+2)Simple Monitoring Web-Pages YesMonitoring Web-Pages with historical data NoTime ManagementRTC (with battery) Ye sTimeUpdate (NTP & SNTP) Ye sDigital inputsTwo DI WAGES & Dry-Contact NoEnvironmentalProtection Degree Front Face IP40Others IP20OverVoltage Category OVC IIIPolution Degree 2Temperature Operation -25 °C to +60 °CStorage -40 °C to +85 °CAltitude Max. 2000 mRelative Humidityy 93%MechanicalForm factor Acti9Installation Din RailWidth 54 mmWeight TBCStandard & CertificationCertifications CE, CULus, RCM, UKCA, FCC, ICStandards IEC 61010-2, UL 61010-2, CSA C22.2, IEC 62974-1, IEC 62443-4-1, IEC 61326-1, EN 301-489, EN 55032, CISPR 11, EN 300-328, IEEE 802.15.4, IEEE 802.11 a/b/g/nECOSTRUXURE™ PANEL SERVER FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 30/05/2022PLSED310126EN_06128
Please see the appropriate Installation Guide for accurate and complete information on the installation of this product.Panel Server Entry dimensionsPanel Server Entry physical descriptionsDB410980DB410979Panel Server Entry (2.12)54(1.57)40.0mm(inch)(1.57)40.0PAS400Panel Server(3.66)103.1(4.05)(3.34)85.0(1.79)(2.76)(2.54)93.064.770.245.5PAS400Panel ServerETHFEAGBCDABCDEFGPower supply terminal blockEcoStruxure™ Panel Server status LEDBluetooth/Restart buttonQR code to product informationEthernet LED 1: SpeedEthernet LED 2: ActivityEthernet communication portECOSTRUXURE™ PANEL SERVER DIMENSIONS AND CONNECTIONVersion: 1.0 - 30/05/2022PLSED310126EN_06129
Functions• An all-in-one gateway to retrieve data from both your IEEE802.15.4 and Modbus devices.• Connect to your monitoring and control software such asEcoStruxure™ Power Monitoring Expert, EcoStruxure™ PowerOperation or to your Building Management System.• Connect to Schneider cloud applications such as FacilityExpert or Asset Advisor.• Ease of commissioning with EcoStruxure™ Power Commissionsoftware, enabling device plug-and-play and auto-discoveryfeatures.• Ease of operation with user friendly embedded webpages,and data contextualization for more relevant analytics.Main features• Power Supply 24 V DC, 110..240 V AC/DC, 110…277 V AC/DC• Designed to match demanding electrical switchboardenvironment (temperature, humidity electromagneticcompatibility)• Two Ethernet 10Base-T/100Base-T port (supporting switchedor separated network topology)• Wi-Fi• Bluetooth communication for commissioning• Modbus RS-485 serial communication• IEEE 802.15.4 wireless communication• Modbus TCP/IP server and client• Support of HTTPS, NTP, SNTP, DHCP client and server withproxy management• Modbus RS-485 to Modbus/TCP Gateway• Wireless devices concentrator to Modbus/TCP• Two digital inputs (24VDC version only) for contact informationor WAGES pulse meter• Designed through a Secured Development Life Cycle inaccordance to IEC62443-4-1• Commissioning through EcoStruxure™ Power Commission orthrough Embedded Web-Pages• Speed-up commissioning through device list import andconfiguration export to the monitoring software• Fully integrated in Cybersecurity Admin Expert tool to facilitatethe management of cybersecurity in your electrical network’s(User Management with Role Base Access and other securityfeatures such as enabling/disabling communication means)• Embedded web server for real-time measurementvisualization, power consumption by usage• Customizable alarm with alarm log• Alarms can be viewed in the web-pages and notified by e-mailCompatible accessories• Wi-Fi/Bluetooth external antenna (PASA-ANT1)eLISTEDCUSStandards & certifications• IEC 61010-1 Ed.2010• UL 61010-1 Ed.2012• IEC 61974• IEC 62443Comm. Reference DescriptionPAS600LPanel Server Universal with 24 V DC power supplyPAS600TPanel Server Universal with 100-240 V AC/DC power supplyPAS600Panel Server Universal with 100-277 V AC/DC power supplyPanel Server UniversalDB410983Panel Server Universal - Front ISO viewECOSTRUXURE™ PANEL SERVER FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 30/05/2022PLSED310126EN_06130
(+1) Consult the User Manual or other documentations to check the limit applicable to your wireless device.(+2) Lower limits may apply depending the firmware version, consult the User Manual, Release Notes or other documentations.Panel Server UniversalPanel Server Universal technical specificationTechnical data EcoStruxure™ Panel Server UniversalCommercial Reference PAS600L PAS600T PAS600Power SupplyVoltage 24 V DC 110-240 V AC/DC 110-277 V AC/DCTolerance ± 10%Frequency N.A. 47-63 Hz 45-65 HzMaximum consumption 3 W 3 W / 10 VA Ethernet & Wi-FiEthernet 10/100base TNumber of Ports Two RJ45 portsPoE 802.3af & 802.3at Class 0 NoWi-Fi Supported Frequency 2.4 GHzTCP/IP YesIP V4 / IP V6 YesDPWS YesDHCP Client YesServer (Separate Nework) Ye sModbus/TCP Server Max. number of client connection 64 (+2)Modbus/TCP Client Max. number of TCP/Modbus devices 64 (+2)Schneider Cloud Services YesHTTPS YesExternal Wi-Fi/Bluetooth Antenna PASA-ANT1Wireless Devices (IEEE 802.15.4)Number of devices Total 100 devices (+2)PowerTag Energy & Ambient (+1)100 devices (+2)Other type of devices (+1)20 devices (+2)External IEEE 802.15.4 Antenna Yes (2022)Serial PortsModbus RS-485 MasterMax. number of devices w/o repeater 32 devicesMax. number of devices with repeater 128 devicesMaximum Length 1000 mBaudrate 1200, 4800, 9600, 19200, 38400, 57600, 115200FunctionalityData Buffering for cloud applications 1 monthData Logger and Web-ServerData Logging NoEvent logging Yes (+2)Simple Monitoring Web-Pages YesMonitoring Web-Pages with historical data NoTime ManagementRTC (with battery) YesTimeUpdate (NTP & SNTP) YesDigital inputsTwo DI WAGES & Dry-Contact Yes NoEnvironmentalProtection Degree Front Face IP40Others IP20OverVoltage Category NA OVC IIIPolution Degree 3 2Temperature Operation -25°C to +70°CStorage -40°C to +85°CAltitude Max. 2000 mRelative Humidityy 93%MechanicalForm factor Acti9Installation Din RailWidth 72 mmWeight TBCStandard & CertificationCertifications CE, CULus, RCM, UKCA, FCC, ICStandards IEC 61010-2, UL 61010-2, CSA C22.2, IEC 62974-1, IEC 62443-4-1, IEC 61326-1, EN 301-489, EN 55032, CISPR 11, EN 300-328, IEEE 802.15.4, IEEE 802.11 a/b/g/nECOSTRUXURE™ PANEL SERVER FUNCTIONS AND CHARACTERISTICS131Version: 1.0 - 30/05/2022PLSED310126EN_06
Please see the appropriate Installation Guide for accurate and complete information on the installation of this product.Panel Server Universal dimensionsPanel Server Universal physical descriptionsDB410985DB410984Panel Server UniversalPAS600LPanel Server(2.83)72(3.66)104.2(4.10)(3.34)85.0(1.79)(2.76)(2.54)93.064.764.770.245.5(1.57)40.0mm(inch)(1.57)40.0PAS600LPanel ServerWi-FiantennaETH1 ETH2D1/+ D0/-RS4850V78910FEA G G HH LI J KBCDABCHDIEJFKGLPower supply terminal blockDigital input terminal block (PAS600L only)EcoStruxure™ Panel Server status LEDBluetooth/Restart buttonQR code to product informationRS-485 Modbus communication portEthernet LED 1: SpeedEthernet LED 2: ActivityWi-Fi external antenna portEthernet 1 communication portEthernet 2 communication portGrounding connectionECOSTRUXURE™ PANEL SERVER DIMENSIONS AND CONNECTIONVersion: 1.0 - 30/05/2022PLSED310126EN_06132
Functions• An all-in-one gateway to retrieve data from both your wirelessIEEE 802.15.4 devices and Modbus devices.• Connect to your monitoring and control software such asEcoStruxure™ Power Monitoring Expert, EcoStruxure™ PowerOperation or to your Building Management System.• Connect to Schneider cloud applications such as FacilityExpert or Asset Advisor.• Ease of commissioning with EcoStruxure™ Power Commissionsoftware, enabling device plug-and-play and auto-discoveryfeatures.• Ease of operation with user friendly embedded webpages,and data contextualization for more relevant analytics.Main features• Power Supply 24 V DC, 110…277 V AC/DC, PoE-PD (CLASS0,IEEE802.3af/at)• Designed to match demanding electrical switchboardenvironment (temperature, humidity electromagneticcompatibility)• Two Ethernet 10Base-T/100Base-T port (supporting switchedor separated network topology)• Wi-Fi• Bluetooth communication for commissioning• Modbus RS-485 serial communication• IEEE 802.15.4 wireless communication• Modbus TCP/IP server and client• Support of HTTPS, NTP, SNTP, DHCP client and server withproxy management• Modbus RS-485 to Modbus/TCP Gateway• Wireless devices concentrator to Modbus/TCP• Two digital inputs (24 V DC version only) for contactinformation or WAGES pulse meter• Designed through a Secured Development Life Cycle inaccordance to IEC 62443-4-1• Commissioning through EcoStruxure™ Power Commission orthough Embedded Web-Pages• Speed-up commissioning through device list import andconfiguration export to the monitoring software• Fully integrated in Cybersecurity Admin Expert tool for securitysettings (Role Base Access and other security features suchenabling/disabling communication means)• Embedded web server for real-time measurement and alarmvisualization, energy & power consumption by usage andlocation, 3 years historical trending and dashboarding• 3 years Data Logger with 32 GB memory• Customizable alarm with alarm log• Alarms can be viewed in the web-pages and notified by e-mailCompatible accessories• Wi-Fi/Bluetooth external antenna (PASA-ANT1)• IEEE 802.15.4 external antenna (PASA-ANT1)eLISTEDCUSStandards & certifications• IEC 61010-1 Ed.2010• UL 61010-1 Ed.2012• IEC 61974• IEC 62443Comm. Reference DescriptionPAS800LPanel Server Advanced with 24 V DC power supplyPAS800PPanel Server Advanced with PoE power supplyPAS800Panel Server Advanced with 100-277 V AC/DC power supplyPanel Server AdvancedPanel Server Advanced- Front ISO viewDB410992ECOSTRUXURE™ PANEL SERVER FUNCTIONS AND CHARACTERISTICS133Version: 1.0 - 30/05/2022PLSED310126EN_06
(+1) Consult the User Manual or other documentations to check the limit applicable to your wireless device.(+2) Lower limits may apply depending the firmware version, consult the User Manual, Release Notes or other documentations.Panel Server AdvancedPanel Server Advanced technical specificationTechnical data EcoStruxure™ Panel Server AdvancedCommercial Reference PAS800L PAS800P PAS800Power SupplyVoltage 24 V DC PoE 110-277 V AC/DCTolerance ± 10 % ± 10 %Frequency N.A. 45-65 HzMaximum consumption 3 W 3.5 W 3 W / 10 VAEthernet & Wi-FiEthernet 10/100base TNumber of Ports Two RJ45 portsPoE 802.3af & 802.3at Class 0 No 1 port (PD) NoWi-Fi Supported Frequency 2.4 & 5 GHzTCP/IP YesIP V4 / IP V6 YesDPWS YesDHCP Client YesServer (Separate Nework) YesModbus/TCP Server Max. number of client connection 64 (+2)Modbus/TCP Client Max. number of TCP/Modbus devices 64 (+2)Schneider Cloud Services YesHTTPS YesExternal Wi-Fi/Bluetooth Antenna PASA-ANT1Wireless Devices (IEEE 802.15.4)Number of devices Total 100 devices (+2)PowerTag Energy & Ambient (+1)100 devices (+2)Other type of devices (+1)20 devices (+2)External IEEE 802.15.4 Antenna PASA-ANT1Serial PortsModbus RS-485 MasterMax. number of devices w/o repeater 32 devicesMax. number of devices with repeater 128 devicesMaximum Length 1000 mBaudrate 1200, 4800, 9600, 19200, 38400, 57600, 115200FunctionalityData Buffering for cloud applications 1 monthData Logger and Web-ServerData Logging 3 yearsEvent logging Yes (+2)Simple Monitoring Web-Pages YesMonitoring Web-Pages with historical dataYesTime ManagementRTC (with battery) YesTimeUpdate (NTP & SNTP) YesDigital inputsTwo DI WAGES & Dry-Contact Yes NoEnvironmentalProtection Degree Front Face IP40Others IP20OverVoltage Category NA OVC IIIPolution Degree 3 2Temperature Operation -25°C to +70°CStorage -40°C to +85°CAltitude Max. 2000 mRelative Humidityy 93%MechanicalForm factor Acti9Installation Din RailWidth 72 mmWeight TBCStandard & CertificationCertifications CE, CULus, RCM, UKCA, FCC, ICStandards IEC 61010-2, UL 61010-2, CSA C22.2, IEC 62974-1, IEC 62443-4-1, IEC 61326-1, EN 301-489, EN 55032, CISPR 11, EN 300-328, IEEE 802.15.4, IEEE 802.11 a/b/g/nIEEE 802.3 af/atECOSTRUXURE™ PANEL SERVER FUNCTIONS AND CHARACTERISTICSVersion: 1.0 - 30/05/2022PLSED310126EN_06134
Please see the appropriate Installation Guide for accurate and complete information on the installation of this product.Panel Server Advanced dimensionsPanel Server Advanced physical descriptionsDB410989DB410990Panel Server Advanced2.83723.66104,24.103.3485,01.792.762.5493,064,770,245,51.5740,01.5740,0PAS800LPanel ServerPAS800LDABCEFWi-FiantennaETH1 ETH2(PoE)D1/+ D0/-RS4850V78910JI KG H G HMLABCHDIEJFKGLMPower supply terminal block (PAS800 & PAS800L only)Digital input terminal block (PAS800L only)EcoStruxure™ Panel Server status LEDBluetooth/Restart buttonQR code to product informationRS-485 Modbus communication portEthernet LED 1: SpeedEthernet LED 2: ActivityWi-Fi external antenna portEthernet 1 communication portEthernet 2 communication port (PAS800 & PAS800L only) / Ethernet 2 communication port - PoE (PAS800P only) Grounding connectionIEE802.15.4 external antenna portECOSTRUXURE™ PANEL SERVER DIMENSIONS AND CONNECTIONVersion: 1.0 - 30/05/2022PLSED310126EN_06135
Commercial reference numberDescription PageCurrent Transformers8CT Ip/5 A ratio916550 44 x 66 x 37 Adapter for DIN rails Mounting plate1655156 x 84 x 60 Adapter for DIN rails Mounting plate, insulated locking screwMETSECT5CC004 CC 40 AMETSECT5CC005 CC 50 AMETSECT5CC006 CC 60 AMETSECT5CC008 CC 75 AMETSECT5CC010 CC 100 AMETSECT5CC013 CC 125 AMETSECT5CC015 CC 150 AMETSECT5CC020 CC 200 AMETSECT5CC025 CC 250 AMETSECT5MB025 MB 250 AMETSECT5MB030 MB 300 AMETSECT5MB040 MB 400 AMETSECT5MA015 MA 150 AMETSECT5MA020 MA 200 AMETSECT5MA025 MA 250 AMETSECT5MA030 MA 300 AMETSECT5MA040 MA 400 AMETSECT5MC025 MC 250 AMETSECT5MC030 MC 300 AMETSECT5MC040 MC 400 AMETSECT5MC050 MC 500 AMETSECT5MC060 MC 600 AMETSECT5MC080 MC 800 AMETSECT5MD050 MD 500 AMETSECT5MD060 MD 600 AMETSECT5MD080 MD 800 AMETSECT5CYL1 Cylinder 8.5 mm dia.METSECT5CYL2 Cylinder 10.5 mm dia.METSECT5COVER sealable cover 60.5 x 22 x 23.5 mm for CT TIMETSECT5VV500 CT tropicalised 5000 5 bars 55x165METSECT5VV600 CT tropicalised 6000 5 bars 55x165METSECT5DA040 CT tropicalised 400 5 dual out. bars 32x65METSECT5DA050 CT tropicalised 500 5 dual out. bars 32x65METSECT5DA060 CT tropicalised 600 5 dual out. bars 32x65METSECT5DA080 CT tropicalised 800 5 dual out. bars 32x65METSECT5DA100 CT tropicalised 1000 5 dual out. bars 32x65METSECT5DA125 CT tropicalised 1250 5 dual out. bars 32x65METSECT5DA150 CT tropicalised 1500 5 dual out. bars 32x65METSECT5DB100 CT tropicalised 1000 5 dual out. bars 38x127METSECT5DB125 CT tropicalised 1250 5 dual out. bars 38x127METSECT5DB150 CT tropicalised 1500 5 dual out. bars 38x127METSECT5DB200 CT tropicalised 2000 5 dual out. bars 38x127METSECT5DB250 CT tropicalised 2500 5 dual out. bars 38x127Commercial reference numberDescription PageMETSECT5DB300 CT tropicalised 3000 5 dual out. bars 38x127METSECT5DC200 CT tropicalised 2000 5 dual out. bars 52x127METSECT5DC250 CT tropicalised 2500 5 dual out. bars 52x127METSECT5DC300 CT tropicalised 3000 5 dual out. bars 52x127METSECT5DC400 CT tropicalised 4000 5 dual out. bars 52x127METSECT5DD100 CT tropicalised 1000 5 dual out. bars 34x84METSECT5DD125 CT tropicalised 1250 5 dual out. bars 34x84METSECT5DD150 CT tropicalised 1500 5 dual out. bars 34x84METSECT5DE100 CT tropicalised 1000 5 dual out. bars 54x102METSECT5DE125 CT tropicalised 1250 5 dual out. bars 54x102METSECT5DE150 CT tropicalised 1500 5 dual out. bars 54x102METSECT5DE200 CT tropicalised 2000 5 dual out. bars 54x102METSECT5DH125 CT tropicalised 1250 5 dual out. bars 38x102METSECT5DH150 CT tropicalised 1500 5 dual out. bars 38x102METSECT5DH200 CT tropicalised 2000 5 dual out. bars 38x102Split core CTs 19Busbar Type HFrame 1METSECT5HA015 IEC Split Core CT Cable 150/5 A 1 VA cl.1METSECT5HA020 IEC Split Core CT Cable 200/5 A 1.5 VA cl.1METSECT5HA025 IEC Split Core CT Cable 250/5 A 1 VA cl.0.5Frame 2METSECT5HD025 IEC Split Core CT Cable 250/5 A 1 VA cl.1METSECT5HD030 IEC Split Core CT Cable 300/5 A 1.5 VA cl.1METSECT5HD040 IEC Split Core CT Cable 400/5 A 2.5 VA cl.1 METSECT5HD050 IEC Split Core CT Cable 500/5 A 1VA cl.0.5 Frame 3METSECT5HG010 IEC Split Core CT Cable 100/5 A 1.5 VA cl.3METSECT5HG013 IEC Split Core CT Cable 125/5 A 2.5 VA cl.3METSECT5HG015 IEC Split Core CT Cable 150/5 A 3 VA cl.3METSECT5HG020 IEC Split Core CT Cable 200/5 A 3 VA cl.3METSECT5HG025 IEC Split Core CT Cable 250/5 A 3 VA cl.3METSECT5HG030 IEC Split Core CT Cable 300/5 A 2.5 VA cl.1METSECT5HG040 IEC Split Core CT Cable 400/5 A 5 VA cl.1METSECT5HG050 IEC Split Core CT Cable 500/5 A 5 VA cl.1METSECT5HG060 IEC Split Core CT Cable 600/5 A 5 VA cl.1Frame 4METSECT5HJ030 IEC Split Core CT Cable 300/5 A 2.5 VA cl.1METSECT5HJ040 IEC Split Core CT Cable 400/5 A 5VA cl.1METSECT5HJ050 IEC Split Core CT Cable 500/5 A 5VA cl.1METSECT5HJ060 IEC Split Core CT Cable 600/5 A 2.5 VA cl.0.5METSECT5HJ075 IEC Split Core CT Cable 750/5 A 2.5 VA cl.0.5METSECT5HJ080 IEC Split Core CT Cable 800/5 A 2.5 VA cl.0.5Commercial Reference NumbersVersion: 1.0 - 09/05/2022PLSED310126EN_07136POWERLOGIC™ CATALOG COMMERCIAL REFERENCE NUMBERS
Commercial reference numberDescription PageRogowski CTs 24METSECTR25500 Rogowski CT, 250 mm core length, 80 mm dia.METSECTR30500 Rogowski CT, 300 mm core length, 96 mm dia.METSECTR46500 Rogowski CT, 400 mm core length, 146 mm dia.METSECTR60500 Rogowski CT, 600 mm core length, 191 mm dia.METSECTR90500 Rogowski CT, 900 mm core length, 287 mm dia.Panel Instruments25DIN rail analog ammeters, voltmeters 2616029 0-30 A no 816030 X/5 816031 0-5 A16032 0-50 A 50/516033 0-75 A 75/516034 0-100 A 100/516035 0-150 A 150/516036 0-200 A 200/516037 0-250 A 250/516038 0-300 A 300/516039 0-400 A 400/516040 0-500 A 500/516041 0-600 A 600/516042 0-800 A 800/516043 0-1000 A 1000/516044 0-1500 A 1500/516045 0-2000 A 2000/516060 0-300 V 816061 0-500 V 8DIN rail digital ammeters, voltmeter, frequency meter2715202 Direct reading iAMP 0-10 A No 415209 Multi-rating iAMP 0-5000 A As per rating 415201 iVLT 0-600 V 415208 iFRE 20-100 Hz 472x72 analog ammeter, voltmeter2816003 AMP for motor feeder16004 AMP for standard feeder X/516009 AMP for standard feeder 0-50 A 50/516010 AMP for standard feeder 0-100 A 100/516011 AMP for standard feeder 0-200 A 200/516012 AMP for standard feeder 0-400 A 400/516013 AMP for standard feeder 0-600 A 600/516014 AMP for standard feeder 0-1000 A 1000/516015 AMP for standard feeder 0-1250 A 1250/516016 AMP for standard feeder 0-1500 A 1500/516019 AMP for standard feeder 0-2000 A 2000/516006 AMP for motor feeder 0-30-90 A 30/516007 AMP for motor feeder 0-75-225 A 75/516008 AMP for motor feeder 0-200-600 A 200/516005 VLT 0-500 V96x96 analog ammeter, voltmeter2916074 AMP for standard feeder X/516079 AMP for standard feeder 0-50 A 50/516080 AMP for standard feeder 0-100 A 100/516081 AMP for standard feeder 0-200 A 200/516082 AMP for standard feeder 0-400 A 400/516083 AMP for standard feeder 0-600 A 600/516084 AMP for standard feeder 0-1000 A 1000/516085 AMP for standard feeder 0-1250 A 1250/516086 AMP for standard feeder 0-1500 A 1500/516087 AMP for standard feeder 0-2000 A 2000/516088 AMP for standard feeder 0-2500 A 2500/516089 AMP for standard feeder 0-3000 A 3000/5Commercial reference numberDescription PageFrame 5METSECT5HM030 IEC Split Core CT Cable 300/5 A 2.5 VA cl.1METSECT5HM040 IEC Split Core CT Cable 400/5 A 5 VA cl.1METSECT5HM050 IEC Split Core CT Cable 500/5 A 5 VA cl.1METSECT5HM060 IEC Split Core CT Cable 600/5 A 2.5 VA cl.0.5METSECT5HM075 IEC Split Core CT Cable 750/5 A 2.5 VA cl.0.5METSECT5HM080 IEC Split Core CT Cable 800/5 A 2.5 VA cl.0.5Frame 6METSECT5HP025 IEC Split Core CT Cable 250/5 A 1.5 VA cl.1METSECT5HP030 IEC Split Core CT Cable 300/5 A 2.5 VA cl.1METSECT5HP040 IEC Split Core CT Cable 400/5 A 5 VA cl.1METSECT5HP050 IEC Split Core CT Cable 500/5 A 5 VA cl.1METSECT5HP060 IEC Split Core CT Cable 600/5 A 5 VA cl.1METSECT5HP075 IEC Split Core CT Cable 750/5 A 5 VA cl.1METSECT5HP080 IEC Split Core CT Cable 800/5 A 5 VA cl.1METSECT5HP100 IEC Split Core CT Cable 1000/5 A 5 VA cl.1Busbar Type GFrame 7METSECT5GA010 IEC CT Split Core Busbar 100/5 A 1.25 VA cl.3METSECT5GA015 IEC CT Split Core Busbar 150/5 A 1.5 VA cl.3METSECT5GA020 IEC CT Split Core Busbar 200/5 A 2.5 VA cl.3METSECT5GA025 IEC CT Split Core Busbar 250/5 A 1.5 VA cl.1METSECT5GA030 IEC CT Split Core Busbar 300/5 A 3.75 VA cl.1METSECT5GA040 IEC CT Split Core Busbar 400/5 A 1 VA cl.0.5Frame 8METSECT5GD025 IEC CT Split Core Busbar 250/5 A 1.5 VA cl.1METSECT5GD030 IEC CT Split Core Busbar 300/5 A 2.5 VA cl.1METSECT5GD040 IEC CT Split Core Busbar 400/5 A 1 VA cl.0.5METSECT5GD050 IEC CT Split Core Busbar500/5 A 2.5 VA cl.0.5METSECT5GD060 IEC CT Split Core Busbar 600/5 A 2.5 VA cl.0.5METSECT5GD075 IEC CT Split Core Busbar 750/5 A 2.5 VA cl.0.5METSECT5GD080 IEC CT Split Core Busbar 800/5 A 2.5 VA cl.0.5METSECT5GD100 IEC CT Split Core Busbar 1000/5 A 5 VA cl.0.5Frame 9METSECT5GG025 IEC CT Split Core Busbar 250/5 A 1.5 VA cl.1METSECT5GG030 IEC CT Split Core Busbar 300/5 A 2.5 VA cl.1METSECT5GG040 IEC CT Split Core Busbar 400/5 A 2.5 VA cl.1METSECT5GG050 IEC CT Split Core Busbar 500/5 A 2.5 VA cl.0.5METSECT5GG060 IEC CT Split Core Busbar 600/5 A 2.5 VA cl.0.5METSECT5GG075 IEC CT Split Core Busbar 750/5 A 2.5 VA cl.0.5METSECT5GG080 IEC CT Split Core Busbar 800/5 A 2.5 VA cl.0.5METSECT5GG100 IEC CT Split Core Busbar 1000/5 A 5 VA cl.0.5METSECT5GG120 IEC CT Split Core Busbar 1200/5 A 5 VA cl.0.5METSECT5GG125 IEC CT Split Core Busbar 1250/5 A 7.5 VA cl.0.5METSECT5GG150 IEC CT Split Core Busbar 1500/5 A 7.5 VA cl.0.5Frame 10METSECT5GJ100 IEC CT Split Core Busbar 1000/5 A 10 VA cl.0.5METSECT5GJ120 IEC CT Split Core Busbar 1200/5 A 10 VA cl.0.5METSECT5GJ150 IEC CT Split Core Busbar 1500/5 A 10 VA cl.0.5METSECT5GJ160 IEC CT Split Core Busbar 1600/5 A 10 VA cl.0.5METSECT5GJ200 IEC CT Split Core Busbar 2000/5 A 10 VA cl.0.5METSECT5GJ250 IEC CT Split Core Busbar 2500/5 A 10 VA cl.0.5METSECT5GJ300 IEC CT Split Core Busbar 3000/5 A 15 VA cl.0.5METSECT5GJ400 IEC CT Split Core Busbar 4000/5 A 15 VA cl.0.5PowerLogic™ Commercial Reference Numbers137Version: 1.0 - 09/05/2022PLSED310126EN_07POWERLOGIC™ CATALOG COMMERCIAL REFERENCE NUMBERS
Commercial reference numberDescription Page16090 AMP for standard feeder 0-4000 A 4000/516091 AMP for standard feeder 0-5000 A 5000/516092 AMP for standard feeder 0-6000 A 6000/516073 AMP for motor feeder X/516076 AMP for motor feeder 0-30-90 A 30/516077 AMP for motor feeder 0-75-225 A 75/516078 AMP for motor feeder 0-200-600 A 200/516075 VLT 0-500 V48x48 CMA, CMV selector switches3016017 CMA 20 416018 CMV 500 7DIN rail iCMA, iCMV selector switches3215126 iCMA 10 415 415125 iCMV 10 415 4iCH hour counter3215440 iCH "DIN" 230 V AC ± 10 %/50 Hz 4mm15607 CH "48 x 48" 24 V AC ± 10 %/50 Hz15608 CH "48 x 48" 230 V AC ± 10 %/50 Hz15609 CH "48 x 48" 12 to 36 V DCiCI impulse counter3315443 iCI 4mm impulse counter DINBasic Energy Metering36iEM2xxx37A9MEM2000T iEM2000T basic energy meter, no displayA9MEM2000 iEM2000 basic energy meterA9MEM2010 iEM2010 energy meter, kWh pulse outputA9MEM2100 iEM2100 basic energy meterA9MEM2050iEM2050 modular single phase power meter 230 V - 45 A with ModbusA9MEM2055iEM2055 modular single phase power meter 230 V - 45 A with Modbus, MIDA9MEM2105iEM2105 energy meter, kWh pulse output with partial meterA9MEM2110iEM2110 energy meter, kWh and kvarh pulse outputs with two tariffs, four quadrant energy measurement, MID certifiedA9MEM2135iEM2135 energy meter, M-Bus communication, four quadrant energy measurement, two tariffs, MID certifiedA9MEM2150iEM2150 energy meter, Modbus communication, four quadrant energy measurementA9MEM2155iEM2155 energy meter, Modbus communication, four quadrant energy measurement, two tariffs, MID certifiedA9MEM2435iEM2435 power and energy meter, Class 1, 230 V, 100 A, M-Bus, MID, 2 tariffs, 2 pulse outputs, 4 quadrants, LCD displayA9MEM2455iEM2455 power and energy meter, Class 1, 230 V, 100 A, RS-485, MID, 2 tariffs, 2 pulse outputs, 4 quadrants, LCD displayiEM300042A9MEM3100 iEM3100 basic energy meterA9MEM3110 iEM3110 energy meter with pulse outputA9MEM3115 iEM3115 multi-tariff energy meterA9MEM3135iEM3135 advanced multi-tariff energy meter & electrical parameter plus M-Bus comm portA9MEM3150iEM3150 energy meter & electrical parameter plus Modbus RS-485 comm portA9MEM3155iEM3155 advanced multi-tariff energy meter & electrical parameter plus Modbus RS-485 comm portA9MEM3165iEM3165 advanced multi-tariff energy meter & electrical parameter plus BACnet MS/TP comm portA9MEM3175iEM3175 advanced multi-tariff energy meter & electrical parameter plus LON TP/FT-10 comm portA9MEM3200 iEM3200 basic energy meterA9MEM3210 iEM3210 energy meter with pulse outputA9MEM3215 iEM3215 multi-tariff energy meterA9MEM3235iEM3235 advanced multi-tariff energy meter & electrical parameter plus M-Bus comm portCommercial reference numberDescription PageA9MEM3250iEM3250 energy meter & electrical parameter plus Modbus RS-485 comm portA9MEM3255iEM3255 advanced multi-tariff energy meter & electrical parameter plus Modbus RS485 comm portA9MEM3265iEM3265 advanced multi-tariff energy meter & electrical parameter plus BACnet MS/TP comm portA9MEM3275iEM3275 advanced multi-tariff energy meter & electrical parameter plus LON TP/FT-10 comm portA9MEM3300 iEM3300 basic energy meterA9MEM3310 iEM3310 energy meter with pulse outputA9MEM3335iEM3335 advanced multi-tariff energy meter & electrical parameter plus M-Bus comm portA9MEM3350iEM3350 energy meter & electrical parameter plus Modbus RS-485 comm portA9MEM3355iEM3355 advanced multi-tariff energy meter & electrical parameter plus Modbus RS485 comm portA9MEM3365iEM3365 advanced multi-tariff energy meter & electrical parameter plus BACnet MS/TP comm portA9MEM3375iEM3375 advanced multi-tariff energy meter & electrical parameter plus LON TP/FT-10 comm portA9MEM3455iEM3455 advanced multi-tariff energy meter & electrical parameter plus Modbus RS-485 comm portA9MEM3465iEM3465 advanced multi-tariff energy meter & electrical parameter plus BACnet MS/TP comm portA9MEM3555iEM3555 advanced multi-tariff energy meter & electrical parameter plus Modbus RS-485 comm portA9MEM3565iEM3565 advanced multi-tariff energy meter & electrical parameter plus BACnet MS/TP comm portLVCTs46LVCT00050S CT, split-core, Size 0, 50 A to 0.333 VLVCT00101S CT, split-core, Size 1, 100 A to 0.333 VLVCT00201S CT, split-core, Size 1, 200 A to 0.333 VLVCT00102S CT, split-core, Size 2, 100 A to 0.333 VLVCT00202S CT, split-core, Size 2, 200 A to 0.333 VLVCT00302S CT, split-core, Size 2, 300 A to 0.333 VLVCT00403S CT, split-core, Size 3, 400 A to 0.333 VLVCT00603S CT, split-core, Size 3, 600 A to 0.333 VLVCT00803S CT, split-core, Size 3, 800 A to 0.333 VLVCT00804S CT, split-core, Size 4, 800 A to 0.333 VLVCT01004S CT, split-core, Size 4, 1000 A to 0.333 VLVCT01204S CT, split-core, Size 4, 1200 A to 0.333 VLVCT01604S CT, split-core, Size 4, 1600 A to 0.333 VLVCT02004S CT, split-core, Size 4, 2000 A to 0.333 VLVCT02404S CT, split-core, Size 4, 2400 A to 0.333 VPM300048METSEPM3200 PM3200 basic power meterMETSEPM3210 PM3210 power meter with pulse outputMETSEPM3250 PM3250 power meter with RS485 portMETSEPM3255PM3255 power meter plus 2 digital inputs, 2 digital outputs with RS-485 portPowerTag Energy54A9MEM1520 PowerTag Energy M63 1P+WA9MEM1521 PowerTag Energy M63 1P+N TopA9MEM1522 PowerTag Energy M63 1P+N BottomA9MEM1540 PowerTag Energy M63 3PA9MEM1541 PowerTag Energy M63 3P+N TopA9MEM1542 PowerTag Energy M63 3P+N BottomA9MEM1543 PowerTag Energy M63 3P 230 V LLA9MEM1560 PowerTag Energy F63 1P+NA9MEM1561 PowerTag Energy P63 1P+N TopA9MEM1562 PowerTag Energy P63 1P+N BottomA9MEM1563 PowerTag Energy P63 1P+N B RCBOA9MEM1564 PowerTag Energy F63 1P+N 110 VA9MEM1570 PowerTag Energy F63 3P+NA9MEM1571 PowerTag Energy P63 3P+N TopA9MEM1572 PowerTag Energy P63 3P+N BottomA9MEM1573 PowerTag Energy F63 3PPowerLogic™ Commercial Reference NumbersVersion: 1.0 - 09/05/2022PLSED310126EN_07138POWERLOGIC™ CATALOG COMMERCIAL REFERENCE NUMBERS
Commercial reference numberDescription PageA9MEM1574 PowerTag Energy F63 3P+N 127/220 VA9MEM1580 PowerTag Energy F160 3P / 3P+NA9MEM1590 PowerTag Energy R200 3P / 3P+NA9MEM1591 PowerTag Energy R600 3P / 3P+NA9MEM1592 PowerTag Energy R1000 3P / 3P+NA9MEM1593 PowerTag Energy R2000 3P / 3P+NLV434020 PowerTag Energy M250 3PLV434021 PowerTag Energy M250 3P+NLV434022 PowerTag Energy M630 3PLV434023 PowerTag Energy M630 3P+NR9M20 PowerTag Energy R9 M63 1P+WR9M21 PowerTag Energy R9 M63 1P+N TopR9M22 PowerTag Energy R9 M63 1P+N BottomR9M40 PowerTag Energy R9 M63 3PR9M41 PowerTag Energy R9 M63 3P+N TopR9M42 PowerTag Energy R9 M63 3P+N BottomR9M43 PowerTag Energy R9 M63 3P 230 V LLR9M60 PowerTag Energy R9 F63 1P+NR9M70 PowerTag Energy R9 F63 3P+NWireless Products96PowerTag Control97A9XMC2D3 PowerTag C 2DI 230V digital input moduleHeatTag101SMT10020 HeatTag smart sensor cable overheatingBasic Multi-Function Metering105PM5000115METSEPM5100Power Meter, 600V AC L-L/ 5A or 1A input, 415V AC L-L or 250V DC control power, Cl 0.5S, 15th harmonic, 1DOMETSEPM5110Power Meter, 600V AC L-L/ 5A or 1A input, 415V AC L-L or 250V DC control power, Cl 0.5S, 15th harmonic, 1DO, RS-485METSEPM5111Power Meter, 600V AC L-L/ 5A or 1A input, 415V AC L-L or 250V DC control power, Cl 0.5S, 15th harmonic, 1DO, RS-485, MIDMETSEPM5310Power Meter, 600V AC L-L/ 5A or 1A input, 415V AC L-L or 250V DC control power, Cl 0.5S, 31st harmonic, 256 kB, 2DI/2DO, RS-485METSEPM5310RPower Meter, 600V AC L-L/ RJ45 LVCT input, 415V AC L-L or 250V DC control power, Cl 0.5S, 31st harmonic, 256 kB, 2DI/2DO, RS-485METSEPM5320Power Meter, 600V AC L-L/ 5A or 1A input, 415V AC L-L or 250V DC control power, Cl 0.5S, 31st harmonic, 256 kB, 2DI/2DO, EthernetMETSEPM5320RPower Meter, 600V AC L-L/ RJ45 LVCT input, 415V AC L-L or 250V DC control power, Cl 0.5S, 31st harmonic, 256 kB, 2DI/2DO, EthernetMETSEPM5330Power Meter, 600V AC L-L/ 5A or 1A input, 415V AC L-L or 250V DC control power, Cl 0.5S, 31st harmonic, 256 kB, 2DI/2DO/2-Relay, RS-485METSEPM5331Power Meter, 600V AC L-L/ 5A or 1A input, 415V AC L-L or 250V DC control power, Cl 0.5S, 31st harmonic, 256 kB, 2DI/2DO/2-Relay, RS-485, MIDMETSEPM5340Power Meter, 600V AC L-L/ 5A or 1A input, 415V AC L-L or 250V DC control power, Cl 0.5S, 31st harmonic, 256 kB, 2DI/2DO/2-Relay, EthernetMETSEPM5341Power Meter, 600V AC L-L/ 5A or 1A input, 415V AC L-L or 250V DC control power, Cl 0.5S, 31st harmonic, 256 kB, 2DI/2DO/2-Relay, Ethernet, MIDMETSEPM5560Power Meter, 690V AC L-L/ 5A or 1A input, 480V AC L-L or 250V DC control power, Cl 0.2S, 63rd harmonic, 1.1 MB, 4DI/2-DO, RS-485, EthernetMETSEPM5561Power Meter, 690V AC L-L/ 5A or 1A input, 480V AC L-L or 250V DC control power, Cl 0.2S, 63rd harmonic, 1.1 MB, 4DI/2-DO, RS-485, Ethernet, MIDMETSEPM5562Power Meter, 690V AC L-L/ 5A or 1A input, 480V AC L-L or 250V DC control power, Cl 0.2S, 63rd harmonic, 1.1 MB, 4DI/2-DO, RS-485, Ethernet, RMI CAN approved, Hwardware lockableMETSEPM5562MCPower Meter, 690V AC L-L/ 5A or 1A input, 480V AC L-L or 250V DC control power, Cl 0.2S, 63rd harmonic, 1.1 MB, 4DI/2-DO, RS-485, Ethernet, RMI CAN approved, Factory sealedCommercial reference numberDescription PageMETSEPM5563Power Meter, 690V AC L-L/ 5A or 1A input, 480V AC L-L or 250V DC control power, Cl 0.2S, 63rd harmonic, 1.1 MB, 4DI/2-DO, RS-485, Ethernet, DIN mount, No displayMETSEPM5563RDPower Meter, 690V AC L-L/ 5A or 1A input, 480V AC L-L or 250V DC control power, Cl 0.2S, 63rd harmonic, 1.1 MB, 4DI/2-DO, RS-485, Ethernet, DIN mount, Remote displayMETSEPM5570Power Meter, 690V AC L-L/ 5A or 1A input, 480V AC L-L or 250V DC control power, Cl 0.2S, 63rd harmonic, 1.1 MB, 2DI/2AI/2-DO, RS-485, EthernetMETSEPM5580Power Meter, 690V AC L-L/ 5A or 1A input, 24 to 64V DC control power, Cl 0.2S, 63rd harmonic, 1.1 MB, 4DI/2-DO, RS-485, EthernetMETSEPM5650Power Meter, 690V AC L-L/ 5A or 1A input, 480V AC L-L or 250V DC control power, Cl 0.2S, 63rd harmonic, 1.1 MB, 4DI/2-DO, RS-485, Ethernet, Wave Form Capture and Sag/swellMETSEPM5660Power Meter, 690V AC L-L/ 5A or 1A input, 480V AC L-L or 250V DC control power, Cl 0.2S, 63rd harmonic, 1.1 MB, 2DI/2-DO, RS-485, Ethernet, Residual Current MonitorMETSEPM5661Power Meter, 690V AC L-L/ 5A or 1A input, 480V AC L-L or 250V DC control power, Cl 0.2S, 63rd harmonic, 1.1 MB, 2DI/2-DO, RS-485, Ethernet, Residual Current Monitor, MIDMETSEPM5760Power Meter, 690V AC L-L/ 5A or 1A input, 480V AC L-L or 250V DC control power, Cl 0.2S, 63rd harmonic, 1.1 MB, 2DI/2-DO, RS-485, Ethernet, Wave Form Capture and Sag/swell, Residual current monitorMETSEPM5761Power Meter, 690V AC L-L/ 5A or 1A input, 480V AC L-L or 250V DC control power, Cl 0.2S, 63rd harmonic, 1.1 MB, 2DI/2-DO, RS-485, Ethernet, Wave Form Capture and Sag/swell, Residual current monitor, MIDResidual Current Monitoring Toroids (Vigirex) - Closed Toroids, A Type11550437TA30 - closed toroid A type, for RCM enabled power meters, 30 mm inner diameter, rated current 65 Amps, 1000 turns50438PA50 - closed toroid A type, for RCM enabled power meters, 50 mm inner diameter, rated current 85 Amps, 1000 turns50439IA80 - closed toroid A type, for RCM enabled power meters, 80 mm inner diameter, rated current 160 Amps, 1000 turns50440MA120 - closed toroid A type, for RCM enabled power meters, 120 mm inner diameter, rated current 250 Amps, 1000 turns50441SA200 - closed toroid A type, for RCM enabled power meters, 200 mm inner diameter, rated current 400 Amps, 1000 turns50442GA300 - closed toroid A type, for RCM enabled power meters, 300 mm inner diameter, rated current 630 Amps, 1000 turnsAccessories for Closed Toroids 11556055Magnetic ring/ Iron screen accessory for TA30 toroid sensor56056Magnetic ring/ Iron screen accessory for PA50 toroid sensor56057 Magnetic ring/ Iron screen accessory for IA80 toroid sensor56058Magnetic ring/ Iron screen accessory for MA120 toroid sensorResidual Current Monitoring Toroids (Vigirex) - Split Toroids, OA Type 11550420TOA80 - split toroid OA type, 80 mm inner diameter, rated current 160 Amps, 1000 turns50421TOA120 - split toroid OA type, 120 mm inner diameter, rated current 250 Amps, 1000 turns56053L1 type - rectangular sensor, width 280 x height 115 mm, rated current 1600 Amps, 1000 turns56054L2 type - rectangular sensor, width 470 x height 160 mm, rated current 3200 Amps, 1000 turns0.333V (1/3 Volts), 3-in-1 CTs with RJ45 connetors for PM53x0R LVCT enabled power meter116METSECTV25006LVCT Solid core 3 in 1 with RJ45 cable, 25 mm phase center, 60 Amps, 0.333V outputMETSECTV25010LVCT Solid core 3 in 1 with RJ45 cable, 25 mm phase center, 100 Amps, 0.333V outputMETSECTV25013LVCT Solid core 3 in 1 with RJ45 cable, 25 mm phase center, 125 Amps, 0.333V outputMETSECTV25016LVCT Solid core 3 in 1 with RJ45 cable, 25 mm phase center, 160 Amps, 0.333V outputPowerLogic™ Commercial Reference Numbers139Version: 1.0 - 09/05/2022PLSED310126EN_07POWERLOGIC™ CATALOG COMMERCIAL REFERENCE NUMBERS
Commercial reference numberDescription PageMETSECTV35006LVCT Solid core 3 in 1 with RJ45 cable, 35 mm phase center, 60 Amps, 0.333V outputMETSECTV35010LVCT Solid core 3 in 1 with RJ45 cable, 35 mm phase center, 100 Amps, 0.333V outputMETSECTV35012LVCT Solid core 3 in 1 with RJ45 cable, 35 mm phase center, 120 Amps, 0.333V outputMETSECTV35013LVCT Solid core 3 in 1 with RJ45 cable, 35 mm phase center, 125 Amps, 0.333V outputMETSECTV35015LVCT Solid core 3 in 1 with RJ45 cable, 35 mm phase center, 150 Amps, 0.333V outputMETSECTV35016LVCT Solid core 3 in 1 with RJ45 cable, 35 mm phase center, 160 Amps, 0.333V outputMETSECTV35020LVCT Solid core 3 in 1 with RJ45 cable, 35 mm phase center, 200 Amps, 0.333V outputMETSECTV35025LVCT Solid core 3 in 1 with RJ45 cable, 35 mm phase center, 250 Amps, 0.333V outputMETSECTV45025LVCT Solid core 3 in 1 with RJ45 cable, 45 mm phase center, 250 Amps, 0.333V outputMETSECTV45030LVCT Solid core 3 in 1 with RJ45 cable, 45 mm phase center, 300 Amps, 0.333V outputMETSECTV45040LVCT Solid core 3 in 1 with RJ45 cable, 45 mm phase center, 400 Amps, 0.333V outputMETSECTV45050LVCT Solid core 3 in 1 with RJ45 cable, 45 mm phase center, 500 Amps, 0.333V outputMETSECTV45060LVCT Solid core 3 in 1 with RJ45 cable, 45 mm phase center, 600 Amps, 0.333V outputMETSECTV45063LVCT Solid core 3 in 1 with RJ45 cable, 45 mm phase center, 630 Amps, 0.333V outputMETSECTV29006LVCT Solid core 3 in 1 with RJ45 cable, 29 mm phase center, 60 Amps, 0.333V outputMETSECTV29010LVCT Solid core 3 in 1 with RJ45 cable, 29 mm phase center, 100 Amps, 0.333V outputMETSECTV29012LVCT Solid core 3 in 1 with RJ45 cable, 29 mm phase center, 120 Amps, 0.333V outputMETSECTV29013LVCT Solid core 3 in 1 with RJ45 cable, 29 mm phase center, 125 Amps, 0.333V outputMETSECTV29015LVCT Solid core 3 in 1 with RJ45 cable, 29 mm phase center, 150 Amps, 0.333V outputMETSECTV29016LVCT Solid core 3 in 1 with RJ45 cable, 29 mm phase center, 160 Amps, 0.333V outputMETSECTV29020LVCT Solid core 3 in 1 with RJ45 cable, 29 mm phase center, 200 Amps, 0.333V outputMETSECTV70080LVCT Solid core 3 in 1 with RJ45 cable, 70 mm phase center, 800 Amps, 0.333V outputMETSECTV70100LVCT Solid core 3 in 1 with RJ45 cable, 70 mm phase center, 1000 Amps, 0.333V outputMETSECTV70125LVCT Solid core 3 in 1 with RJ45 cable, 70 mm phase center, 1250 Amps, 0.333V outputCable 116METSEPM5CAB03RJ25 cable assembly for interfacing PM5563 meter and PM5RD remote display with 0.3 meter cable lengthMETSEPM5CAB1RJ25 cable assembly for interfacing PM5563 meter and PM5RD remote display with 1.0 meter cable lengthMETSEPM5CAB10RJ25 cable assembly for interfacing PM5563 meter and PM5RD remote display with 10 meter cable lengthMETSEPM5CAB3RJ25 cable assembly for interfacing PM5563 meter and PM5RD remote display with 3 meter cable lengthMETSEPM5CAB4RJ25 cable assembly for interfacing PM5563 meter and PM5RD remote display with 4 meter cable lengthOther related products 116METSEPM5RDRemote display unit for PM5563 power meter sup-plied with mounting bracket, gasket, anti-rotation pin and RJ25 cable METSEPMCABxyMETSEPM51HKHardware kit for PM51xx comprises 2 retainer clips and spare connectors for - Voltage in, Control power in, Digital IO & RS-485METSEPM53HKHardware kit for PM51xx comprises 2 retainer clips and spare connectors for - Voltage in, Control power in, Digital IO, Relay & RS-485METSEPM51_3RSK Revenue sealing kit for PM51XX & PM53XXMETSEPM55RSK Revenue sealing kit for PM55XXMETSEPM55HK Hardware kit for PM55xxMETSEPM5CAB3 Remote Display cableCommercial reference numberDescription PagePM5350 118METSEPM5350RS-485 Modbus, THD, 4DI, 2RelayMETSEPM5350IBRS-485, 4DI/2Relay, Multi-level alarm, UL480V, 4DI/2RelayMETSEPM5350PBRS-485, 4DI/2Relay, Multi-level alarm, UL300V, 4DI/2Relay METSEPM5350PRS-485 Modbus, THD, 31st Individual harmonics, Multi-tariff, 4DI/2Relay EcoStruxure™ Panel Server 125Panel Server Entry 127PAS400 Panel Server Entry 110..277 V AC/DCPanel Server Universal 130PAS600LPanel Server Universal with 24 V DC power supplyPAS600TPanel Server Universal with 100-240 V AC/DC power supplyPAS600Panel Server Universal with 100-277 V AC/DC power supplyPanel Server Advanced 133PAS800LPanel Server Advanced with 24 V DC power supplyPAS800PPanel Server Advanced with PoE power supplyPAS800Panel Server Advanced with 100-277 V AC/DC power supplyFor any enclosure or product configuration not listed, please see your Schneider Electric Representative for complete ordering information.PowerLogic™ Commercial Reference NumbersVersion: 1.0 - 09/05/2022PLSED310126EN_07140POWERLOGIC™ CATALOG COMMERCIAL REFERENCE NUMBERS
141Version: 1.0 - 09/05/2022PLSED310126EN_07NOTES
Schneider Electric Industries SAS35, Rue Joseph MonierCS 3032392506 Rueil Malmaison CedexRCS Nanterre 954 503 439Capital social 928 298 512 €www.se.comMay 2022 Panel Builders CatalogPLSED310126EN© 2022 - Schneider Electric. All rights reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies.As standards, specifications and designs develop from time to time, please ask for confirmation of the information given in this document.Over 75 % of Schneider Electric products have been awarded the Green Premium ecolabel.www.se.com