Return to flip book view

Draft only, Product Catalogue Bioprocess

Page 1

RondelOPRODUCT CATALOGUE BIOPROCESSIssue 1, 2024RondelO™ is sold as a Component, not as a Final Device and not as a Replacement part, and as such does not hold a CE-mark or a FDA 510(k).TM

Page 2

When accurate results countsAchieve your sampling goalsAddress: Kastellgatan 4, 254 66 Helsingborg, SwedenPhone number: +46 709 64 66 73. General inquries: info@cyto365.comComponent Catalogue Bioprocess, Issue 1, 2024. All rights reserved.Subject to technical changes without prior notice. RondelO™ is sold as a Component, not as a Final Device and not as a Replacement part, and as such does not hold a CE-mark or a FDA 510(k).Prototype Product Catalogue Bioprocess

Page 3

Uniqueness of RondelO™01Accurate input and output improves results02Minimal dead space to prevent contamination 03Add your mediaAdding media to the continuous loop of substances is easy with the RondelO™ handle - simply give it a turn. Each media will be added one at a time and you have the option to include up to six ingredients.Flush your media inThere is a dedicated ”flushing position” (intermediate position) to “flush your media in” this is made possible by the continous loop. Ensure accurate feeding every time with minimum residuals from pre-vious ingredients.InputOutputHarvest your sampleHarvest your sample  turning the RondelO™ handle. Only one sample can be harvested at a time for accurate sampling with minimal residuals from previous ingredients. Flush in between samplingThe dedicated ”flushing position” or ”waste position” ensure accurate sampling every time. 1. When utilizing sampling with a continous loop, the process is made easy without any unnecessary waste. Just aline the handle with a sampling port and then leave the handle in the intermediate position. 2. When utilizing sampling with a waste container/end-line, aged fluid will be wasted before collecting your fresh sample.This results in accurate sampling with minimum residuals from previous samples.

Page 4

Material RondelO™ Handle: Purell Lubrication: NuSil MED-460Tubing sizeOD/ID 4.1/3.0 mm, 0.161/0.118 inch.  ID 1/8" OD 1/4".PressureRondelO™ Female Luer Lock can withstand at least 2 bar water preassure. Data for RondelO™ Barbed connector is not yet released.Flow rateRondelO™ Female Luer Lock is min.150 ml/minute in a flushing position and min.165 ml/minute i a sample/feeding position with gravity. Data for RondelO™ Barbed connector is not yet released.RondelO™ benets• RondelO™ is suitable to be used due to its minimal dead space which is crucial when both adding media to the bioreactor and ensuring accurate rinsing.• When adding media to a bioreactor, the RondelO™ ensures a continuous flow, regardless of the handle position.• All in-between positions (intermediate positions) of the RondelO™ is a designated ”flushing position” to ensure no minimal dead space interfear with the results. This is both for input and output.• RondelO™ with Barbed connector is prepared for automation with mounting plate, aimed for a stepper motor.This is a concept illustration

Page 5

Art no. ComponentsTubing connectorsRondelO™with NFVUVPcs / Box RondelO™ 7-way, 6 Female Luer Lock OD/ID 4.1/3.0 mm, 0.161/0.118 inch No No 1 000 RondelO™ 5-way, 4 Female Luer Lock OD/ID 4.1/3.0 mm, 0.161/0.118 inch No No 1 000 RondelO™ 3-way, 2 Female Luer Lock OD/ID 4.1/3.0 mm, 0.161/0.118 inch No No 1 000  OD/ID 4.1/3.0 mm, 0.161/0.118 inch  No 500  OD/ID 4.1/3.0 mm, 0.161/0.118 inch  No 500  OD/ID 4.1/3.0 mm, 0.161/0.118 inch  No 500X1= Component, 8 = Assembled Single Use SetX= Number of RondelO™ in the Single Use SetArt no. ComponentsTubing connectorsRondelO™with NFVUVPcs / BoxA1001-U1 RondelO™ 7-way, 6 Female Luer Lock OD/ID 4.1/3.0 mm, 0.161/0.118 inch No  1 000A1002-U1 RondelO™ 5-way, 4 Female Luer Lock OD/ID 4.1/3.0 mm, 0.161/0.118 inch No  1 000A1004-U1 RondelO™ 3-way, 2 Female Luer Lock OD/ID 4.1/3.0 mm, 0.161/0.118 inch No  1 000A1011-U1  OD/ID 4.1/3.0 mm, 0.161/0.118 inch   500A1012-U1  OD/ID 4.1/3.0 mm, 0.161/0.118 inch   500A1014-U1  OD/ID 4.1/3.0 mm, 0.161/0.118 inch   500Product index ComponentsArt no. ComponentTubing connectorsRondelO™with NFVUVPcs / Box RondelO™, 7-way, 6 Barbed Connector ID 1/8" OD 1/4" No No 1000

Page 6



Page 7

is easy integrated into any application using the tubing  automation with mounting plateRondelO™ House: Tritan™ COPERondelO™ Handle: Purell™ HDPERondelO™, Barbed connectorBox size: 386x284x183 mmPcs/Box: 1000Drawings not to scaleArt no. TitleTubing connectorsRondelO™with NFVUVPcs / Box RondelO™ 7-way, 6 Barbed connector ID 1/8" OD 1/4" No No 1000

Page 8



Page 9

is easy integrated into any application using the tubing RondelO™ House: Tritan™ COPERondelO™ Handle: Purell™ HDPERondelO™, Female Luer LockBox size: 386x284x183 mmPcs/Box: 1 000Drawings not to scaleArt no. TitleTubing connectorsRondelO™with NFVUVPcs / Box RondelO™ 7-way, 6 Female Luer Lock OD/ID 4.1/3.0 mm, 0.161/0.118 inch No No 1 000 RondelO™ 5-way, 4 Female Luer Lock OD/ID 4.1/3.0 mm, 0.161/0.118 inch No No 1 000 RondelO™ 3-way, 2 Female Luer Lock OD/ID 4.1/3.0 mm, 0.161/0.118 inch No No 1 000  

Page 10



Page 11

is easy integrated into any application using the tubing RondelO™ House: Tritan™ COPERondelO™ Handle: Purell™ HDPENeedle Free Valve: Tritan™ COPE Box size: 386x284x183 mmPcs/Box: 1 000Drawings not to scaleArt no. TitleTubing connectorsRondelO™with NFVUVPcs / Box  OD/ID 4.1/3.0 mm, 0.161/0.118 inch  No 500  OD/ID 4.1/3.0 mm, 0.161/0.118 inch  No 500  OD/ID 4.1/3.0 mm, 0.161/0.118 inch  No 500  

Page 12



Page 13

is easy integrated into any application using the tubing UV master batch: Mevopur-YellowRondelO™ Handle: Purell™ HDPERondelO™, Female Luer LockBox size: 386x284x183 mmPcs/Box: 1 000 Drawings not to scaleArt no. TitleTubing connectorsRondelO™with NFVUVPcs / BoxA1001-U1 RondelO™ 7-way, 6 Female Luer Lock OD/ID 4.1/3.0 mm, 0.161/0.118 inch No  1 000A1002-U1 RondelO™ 5-way, 4 Female Luer Lock OD/ID 4.1/3.0 mm, 0.161/0.118 inch No  1 000A1004-U1 RondelO™ 3-way, 2 Female Luer Lock OD/ID 4.1/3.0 mm, 0.161/0.118 inch No  1 000A1001-U1 A1002-U1 A1004-U1

Page 14



Page 15

is easy integrated into any application using the tubing UV master batch: Mevopur-YellowRondelO™ Handle: Purell™ HDPENeedle Free Valve: Tritan™ COPE Box size: 386x284x183 mmPcs/Box: 1 000Drawings not to scaleArt no. TitleTubing connectorsRondelO™with NFVUVPcs / BoxA1011-U1  OD/ID 4.1/3.0 mm, 0.161/0.118 inch   500A1012-U1  OD/ID 4.1/3.0 mm, 0.161/0.118 inch   500A1014-U1  OD/ID 4.1/3.0 mm, 0.161/0.118 inch   500A1011-U1 A1012-U1 A1014-U1Drawings not to scaleA1011-U1 A1012-U1 A1014-U1

Page 16

STANDARD OR CUSTOMIZED SOLUTIONSThis is a concept illustrationChoose a Primary SUS for a bioreactor with a continous loop or for a bioreactor with an end-line.Add a Secondary SUS with containers. 123Or customize your solution withtubes, connectors, clamps, plugs, bags etc.

Page 17

STANDARD OR CUSTOMIZED SOLUTIONS

Page 18

This is a concept illustration

Page 19

Art no. Continous loopNo. of sampling portsNo. of RondelO™No. of clamps RondelO™ 7-way, 6 Female Luer Lock SUS 6 1 2 RondelO™ 5-way, 4 Female Luer Lock SUS 4 1 2 RondelO™ 3-way, 2 Female Luer Lock SUS 2 1 2 RondelO™ 7-way, 6 Female Luer Lock SUS Extended 6   RondelO™ 5-way, 4 Female Luer Lock SUS Extended 4   RondelO™ 3-way, 2 Female Luer Lock SUS Extended 2  X1= Component, 8 = Assembled Single Use Set X= Number of RondelO™ in the Single Use SetArt no. Continous loopNo. of sampling portsNo. of RondelO™No. of clamps  6 1 2  4 1 2  2 1 2  6    4    2  Product indexArt no. Continous loopNo. of sampling portsNo. of RondelO™No. of clamps RondelO™, 7-way, 6 Barbed Connector SUS 6 1 2 RondelO™, 7-way, 6 Barbed Connector SUS Extended6 

Page 20

accurate extract up to six samples when utilizing sampling with a RondelO™ House: Tritan™ COPERondelO™ Handle: Purell™ HDPEDrawings not to scaleArt no. TitleNo. of sampling portsNo. of RondelO™No. of clamps RondelO™, 7-way, 6 Barbed Connector SUS 6 1 2Primary SUSRondelO™ Barbed ConnectorDrawings not to scaleArt no. TitleNo. of sampling portsNo. of RondelO™No. of clamps RondelO™, 7-way, 6 Barbed Connector SUS 6 1 2Continous loop

Page 21

to extend your sampling solution when utilizing sampling Customize the Single-Use Set Extended with the number RondelO™ House: Tritan™ COPERondelO™ Handle: Purell™ HDPEDrawings not to scaleArt no. TitleNo. of sampling portsNo. of RondelO™No. of clamps RondelO™, 7-way, 6 Barbed Connector SUS Extended 6  Drawings not to scalePrimary SUS ExtendedRondelO™ Barbed Connector Customize the Customize the 

Page 22

accurate extract up to six samples when utilizing sampling with a Primary SUSRondelO™ Female Luer LockRondelO™ House: Tritan™ COPERondelO™ Handle: Purell™ HDPEDrawings not to scaleDrawings not to scaleArt no. TitleNo. of sampling portsNo. of RondelO™No. of clamps RondelO™ 7-way, 6 Female Luer Lock SUS 6 1 2 RondelO™ 5-way, 4 Female Luer Lock SUS 4 1 2 RondelO™ 3-way, 2 Female Luer Lock SUS 2 1 2Continous loop

Page 23

to extend your sampling solution when utilizing sampling Customize the Single-Use Set Extended with the number Primary SUS ExtendedRondelO™ Female Luer LockRondelO™ House: Tritan™ COPERondelO™ Handle: Purell™ HDPEDrawings not to scaleDrawings not to scaleArt no. TitleNo. of sampling portsNo. of RondelO™No. of clamps RondelO™ 7-way, 6 Female Luer Lock SUS Extended 6   RondelO™ 5-way, 4 Female Luer Lock SUS Extended 4   RondelO™ 3-way, 2 Female Luer Lock SUS Extended 2  Continous loopCustomize the Customize the 

Page 24

accurate extract up to six samples when utilizing sampling with a Primary SUSRondelO™ House: Tritan™ COPERondelO™ Handle: Purell™ HDPENeedle Free Valve: Tritan™ COPEDrawings not to scaleDrawings not to scaleArt no. TitleNo. of sampling portsNo. of RondelO™No. of clamps  6 1 2  4 1 2  2 1 2Continous loop

Page 25

to extend your sampling solution when utilizing sampling Customize the Single-Use Set Extended with the number Primary SUS ExtendedRondelO™ RondelO™ House: Tritan™ COPERondelO™ Handle: Purell™ HDPENeedle Free Valve: Tritan™ COPEDrawings not to scaleDrawings not to scaleArt no. TitleNo. of sampling portsNo. of RondelO™No. of clamps  6    4    2  Customize the 

Page 26

This is a concept illustration

Page 27

Art no. End-lineNo. of sampling portsNo. of RondelO™No. of clamps RondelO™ 7-way, 6 Female Luer Lock SUS 6 1 2 RondelO™ 5-way, 4 Female Luer Lock SUS 4 1 2 RondelO™ 3-way, 2 Female Luer Lock SUS 2 1 2 RondelO™ 7-way, 6 Female Luer Lock SUS Extended 6   RondelO™ 5-way, 4 Female Luer Lock SUS Extended 4   RondelO™ 3-way, 2 Female Luer Lock SUS Extended 2  X1= Component, 8 = Assembled Single Use Set X= Number of RondelO™ in the Single Use SetArt no. End-lineNo. of sampling portsNo. of RondelO™No. of clamps  6 1 2  4 1 2  2 1 2  6    4    2  Art no. End-lineNo. of sampling portsNo. of RondelO™No. of clamps RondelO™, 7-way, 6 Barbed Connector SUS 6 1 2 RondelO™, 7-way, 6 Barbed Connector SUS Extended6 Product index

Page 28

accurate extract up to six samples when utilizing sampling with an RondelO™ House: Tritan™ COPERondelO™ Handle: Purell™ HDPEDrawings not to scaleArt no. TitleNo. of sampling portsNo. of RondelO™No. of clamps RondelO™, 7-way, 6 Barbed Connector SUS 6 1 2Primary SUSRondelO™ Barbed ConnectorDrawings not to scaleArt no. TitleNo. of sampling portsNo. of RondelO™No. of clamps RondelO™, 7-way, 6 Barbed Connector SUS 6 1 2End-lineEnd-lineBarbed

Page 29

to extend your sampling solution when utilizing sampling Customize the Single-Use Set Extended with the number RondelO™ House: Tritan™ COPERondelO™ Handle: Purell™ HDPEDrawings not to scaleArt no. TitleNo. of sampling portsNo. of RondelO™No. of clamps RondelO™, 7-way, 6 Barbed Connector SUS Extended 6  Drawings not to scaleArt no. TitleNo. of sampling portsNo. of RondelO™No. of clamps RondelO™, 7-way, 6 Barbed Connector SUS Extended 6  Primary SUS ExtendedRondelO™ Barbed Connector Customize the Barbed

Page 30

accurate extract up to six samples when utilizing sampling with an Primary SUSRondelO™ Female Luer LocksRondelO™ House: Tritan™ COPERondelO™ Handle: Purell™ HDPEDrawings not to scaleDrawings not to scaleArt no. TitleNo. of sampling portsNo. of RondelO™No. of clamps RondelO™ 7-way, 6 Female Luer Lock SUS 6 1 2 RondelO™ 5-way, 4 Female Luer Lock SUS 4 1 2 RondelO™ 3-way, 2 Female Luer Lock SUS 2 1 2End-line

Page 31

to extend your sampling solution when utilizing sampling Customize the Single-Use Set Extended with the number Primary SUS ExtendedRondelO™ Female Luer LocksRondelO™ House: Tritan™ COPERondelO™ Handle: Purell™ HDPEDrawings not to scaleDrawings not to scaleArt no. TitleNo. of sampling portsNo. of RondelO™No. of clamps RondelO™ 7-way, 6 Female Luer Lock SUS Extended 6   RondelO™ 5-way, 4 Female Luer Lock SUS Extended 4   RondelO™ 3-way, 2 Female Luer Lock SUS Extended 2  Customize the 

Page 32

accurate extract up to six samples when utilizing sampling with an Primary SUSRondelO™ House: Tritan™ COPERondelO™ Handle: Purell™ HDPENeedle Free Valve: Tritan™ COPEDrawings not to scaleDrawings not to scaleArt no. TitleNo. of sampling portsNo. of RondelO™No. of clamps  6 1 2  4 1 2  2 1 2End-line

Page 33

to extend your sampling solution when utilizing sampling with a n end-lineCustomize the Single-Use Set Extended with the number Primary SUSRondelO™ RondelO™ House: Tritan™ COPERondelO™ Handle: Purell™ HDPENeedle Free Valve: Tritan™ COPEDrawings not to scaleDrawings not to scaleArt no. TitleNo. of sampling portsNo. of RondelO™No. of clamps  6    4    2  Customize the 

Page 34

Secondary SUS Feeding to the Secondary SUS FeedingFeeding Line 100 mm to LuerFeeding Connection to Luer Barbed Connector

Page 35

Secondary SUS SamplingSecondary SUS Sampling to the Sampling Tube Sampling Bag

Page 36

Product design (R&D) Customized solutions1We will start with a product design drawing and technical feasibility2Optional: We will do a prototype and prototype testing34Production and assembly of your Single-Use System5Optional: Sterilisation of the Single-Use System6Packaging and labeling7Delivery8

Page 37

Components for a customized solutionCheck ValvesClampsSpikesCapsSyringes

Page 38

Let’s collaborateWebpagewww.rondelo.ioGeneral inquries info@cyto365.comPhone number+46 709 64 66 73