Installation Materials Division...the name behind the brandsPRODUCTCATALOGUELV SwitchgearDistribution BoardsConsumer Units Circuit Protection DevicesPROTEUS SWITCHGEAR
INDUSTRIAL SWITCHGEAR DIVISIONProteus are committed to bringing our customers solutions for power distribution and energy efficiency, whilst focusing on the manufacture of switchgear products specifically designed to offer reliability from ‘plant room to plug top’. With many years of experience in Power & Distribution, we can help you make your energy use and distribution systems safer in order to protect your people, assets and business. Our comprehensive array of electrical distribution products, technologies and services, allows architects and facility owners a flexible approach to their electrical distribution needs. With considerable stock within our UK based factory and 800 distributors worldwide, we are ready and able to satisfy all of your power distribution needs.LV Switchboards 4Custom Built LV Systems 5Special MCCB Panelboards 6Specials 7MC Range MCCB Panelboards 8Moulded Case Circuit Breakers 20MCX 3-Phase Distribution Boards 24CBX 3-Phase Distribution Boards 25XL 3-Phase Distribution Boards 26BX 3-Phase Distribution Boards 30ABX 3-Phase Distribution Boards 34IP65 Power Distribution Boards 36Fuse Gear & Isolators 37Changeover Switches 42Busbar Chambers 44ABS Enclosures 46Contactors & Emergency Stops 47Earth Bars 48Circuit Protection Devices 50Surge Protection Devices 55Proteus EV 58Technical 94Section ContentPlease refer to page 50 for circuit protection devicesCONSUMER UNIT DIVISIONFor over 30 years, Proteus Switchgear has been at the forefront of British manufacturing - specialising in the production of domestic consumer units and circuit protective devices, working proficiently to supply a full and varied product range. In addition to our standard product range, we have the ability to offer fully bespoke units, tailored to customer needs to suit any individual installation. At Proteus, we are entirely committed to the design and development of our products with the future in mind. Our values insist that we are continuously endeavouring to provide 100% tested products alongside features and benefits that allow us to excel within the Switchgear industry.Metalclad Consumer Units 66Insulated Consumer Units 78Proteus EV 58Enclosures/Multi-Purpose Units 81Switch Fuses/Fire Alarm Switches 82Metering Ancillary Products 84 Three Phase Consumer Units 86Mantel Units 87Circuit Protection Devices 50Timers 88Contactors & Isolators 89Accessories 90Specials 92Technical Information 94Section Content3
4PROTEUS INDUSTRIAL | LV SWITCHBOARDSForm 2, Form 3 and Form 4 levels of segregation.Multi-function, analogue/digital tariff and non tariff metering.Restricted earth fault protection utilising Class X CTs providing protection of transformer LV windings.Cableways positioned to left or right hand of switchgear or with high/low level pre-connected terminals for front access applications.All switchgear has the option of 3 or 4 pole switching.Manual and automatic changeover systems.Fully integrated automatic PFC including multi-stage ‘switching’ hand/off/auto selection, automatic control relays, contactors, fuse protection (25KVAr, 50KVAr stages as standard, other sizes available).Sealable supply authority CT chambers.Surge suppression.Modular design to customer requirements.Main incomer options up to 2500 amps.LV SwitchboardsGENERAL CONSTRUCTION TO BSEN 61439-1&2 SPECIFIABLE OPTIONS:
5 | PROTEUS INDUSTRIALCUSTOM BUILT LV SYSTEMSWith increasing emphasis on energy conservation, Proteus Switchgear offers the complete range of intrinsic energy management, varying from timeswitch and relay logic to electronic microprocessor control* of lighting, heating and ventilation and fire/security systems.To meet these changing requirements in retail, commercial and industrial applications, Proteus Switchgear manufactures custom-designed energy management panels, typically incorporating the following options:Main incoming isolation/protection up to 800 amps.24 hour essential services distribution.Point of entry/exit key switch controlled services.Fire alarm interlocking.Signage control/extended hours manual override.Emergency lighting test/battery discharge facility.Panels built to specification or in conjunction with our technical departments.*Microprocessor specification to be confirmed by client and system supplier, i.e. unit free issued to Proteus for inclusion within panel.Custom Built LV SystemsENERGY MANAGEMENT PANELS GENERAL CONSTRUCTION TO BSEN 61439-1&2PROTEUS INDUSTRIAL
6PROTEUS INDUSTRIAL | CUSTOM BUILT MCCB BOARDSADDITIONAL FACILITIES THAT CAN BE INCLUDED IN CUSTOM BUILT PANELS: Option of lockable doors for all MCCBs and MCB housings.Segregated cableways to suit specific cable sizes and types. Width and depth to suit.Feeder MCCB busbar section accepts MCCBs rated up to 250 amps as standard. Larger rated outgoing MCCBs can be factory fitted to busbar systems (upto 800A).Distribution busbars up to 800 amps.Standard enclosures to IP3X.IP65 enclosures are also available.Options of main incomer as 3 or 4 pole switching.Options of MCB or multi-function distribution boards.Busbar ratings from 200A to 800A.Changeover systemsSealable Supply Authority ChambersTariff and non-tariff kWh meteringMulti-function meteringSurge suppressionSpecial MCCB PanelboardsGENERAL CONSTRUCTION TO BSEN 61439-1&2
7 | PROTEUS INDUSTRIALSPECIALSFITTED DEVICESMCBs and RCBOs can be fitted and cabled to terminals and contactors / 3 or 5 pin socketsSURGE ARRESTORSType 2 surge arrestor cabled in parallel with supply. Din rail mounted.CABLING ASSISTANCEDevices can be cabled to panel mounted terminals to aid cablingSUPPLY AUTHORITY C.T. CHAMBERSupply authority C.T. chamber with C.T. support plates. Built to specific supply authority requirementsCustom built assemblies to customer requirementsSpecialsPROTEUS INDUSTRIAL
8PROTEUS INDUSTRIAL | MC PANEL BOARD FEATURES250A, 400A and 800A busbar MCCB Panelboards.Available from 3 to 18 triple pole outgoing ways as standard.Factory fitted incoming MCCB/Isolator up to 800A (3 & 4 pole).Outgoing MCCBs can be factory fitted on request.High fault level rating, 36kA Icc.Removable end plates for easy glanding and ease of installation.Standard board width 900 mm allowing easy cabling.Construction gives type 2 and type 3 group mounted segregation to BS EN 61439:Pt1 & 2:2011.Constructed with 1.6 mm thick steel with an epoxy paint finish to RAL7035.Other paint finishes available upon request.Key hole foot fixings for wall mounting.Lift off door hinges.MC Range MCCB PanelboardsKEYFEATURES:3-PHASE PANELBOARDS FULLY COMPLIANT TO BS EN 61439-1&2FEATURES:
9 | PROTEUS INDUSTRIALMC PANEL BOARD FEATURESModern design allows ultimate flexibility with SP & TP MCCBs which can be fitted in any position.Fully shrouded neutral terminal system with clear perspex covers.Main Earth TerminationMain earthing termination point onto high conductivity copper plate and robust bonding throughout.MC Range MCCB PanelboardsOFFERING A COMPREHENSIVE RANGE1.1.Modern DesignModern Design2.Fully Shrouded Neutral Terminal System2.Shrouded Neutral Terminal SystemDoor fitted over outgoing MCCBs as standard using high quality, steel pin hinges. Removable for ease of fitting.3.Removable Door3.Removable DoorOutgoing MCCBs up to 250A TP and 200A SP.4.Outgoing MCCBs4.Outgoing MCCBs5.PROTEUS INDUSTRIAL
10PROTEUS INDUSTRIAL | MCP72/I250MCP32/I200200A MCCB INCOMER OR SWITCH DISCONNECTOR FITTED BOARDS250A MCCB INCOMER OR SWITCH DISCONNECTOR FITTED BOARDS(S) - Add suffix ‘S’ for Switch Disconnector Incomer Fitted Boards e.g. MCP32/I200S200A MCCB INCOMER FITTED BOARDS(S) - Add suffix ‘S’ for Switch Disconnector Incomer Fitted Boards e.g. MCP72/I250S250A MCCB INCOMER FITTED BOARDSMCP42/I200FMCP62/I250FMeasurements:Millimetres (mm) unless stated otherwiseOutgoing Switchgear:Supplied separatelyOutgoing MCCB’s:Upto 250A TP and 200A SPMCCB PANELBOARDS - 250A BUSBAR 36KA ICCNO. of O/G WAYS CAT. NO. - 3 POLE H W D3 MCP32/I200 (S) 500 900 1705 MCP52/I200 (S) 700 900 1707 MCP72/I200 (S) 700 900 17011 MCP112/I200 (S) 950 900 17015 MCP152/I200 (S) 1300 900 17017 MCP172/I200 (S) 1300 900 170NO. of O/G WAYS CAT. NO. - 3 POLE H W D3 MCP32/I250 (S) 500 900 1705 MCP52/I250 (S) 700 900 1707 MCP72/I250 (S) 700 900 17011 MCP112/I250 (S) 950 900 17015 MCP152/I250 (S) 1300 900 17017 MCP172/I250 (S) 1300 900 170NO. of O/G WAYS CAT. NO. - 4 POLE H W D4 MCP42/I200F 1000 900 1706 MCP62/I200F 1200 900 1708 MCP82/I200F 1200 900 17012 MCP122/I200F 1450 900 17016 MCP162/I200F 1800 900 17018 MCP182/I200F 1800 900 170NO. of O/G WAYS CAT. NO. - 4 POLE H W D4 MCP42/I250F 1000 900 1706 MCP62/I250F 1200 900 1708 MCP82/I250F 1200 900 17012 MCP122/I250F 1450 900 17016 MCP162/I250F 1800 900 17018 MCP182/I250F 1800 900 170• Available from 3 to 18 triple pole outgoing ways.• Factory fitted incoming MCCB/isolator up to 250A 3/4 pole.• These boards utilise the busbar ability to accept 250A MCCBs by using one way as the incoming position when a 3 pole incomer is acceptable.• Reduced height where space is at a premium.• Any rating of MCCB up to 250A can be used as the incomer.• The incoming device is fitted at the top right as standard to allow cable spreading room, this can be moved to any position.• Range of side extension boxes, side meter boxes, bottom extension boxes and corner boxes to suit 250A range of MC panels.• Bottom extension boxes are available in 200 or 300 mm height as standard.• Side extension and meter boxes are available in left/right hand and 3/4 pole versions sized to suit all 250A range MC panels• Corner boxes available when using side and bottom boxes to give a clean look.• Meters, SPDs and Earth Leakage Units are also available.MC Range MCCB PanelboardsFEATURES:WALLMOUNTEDSIDEHINGEDDOORWALLMOUNTEDSIDEHINGEDDOORWALLMOUNTEDSIDEHINGEDDOORWALLMOUNTEDSIDEHINGEDDOOR
11 | PROTEUS INDUSTRIALPROTEUS INDUSTRIAL4 POLESIDE EXTENSION BOX3 & 4 POLE INCOMERSIDE METER EXTENSION BOX3 & 4 POLE INCOMERMCPMB52RBOTTOM EXTENSION BOX CORNER EXTENSION BOX MCPCB34L* - To suit four pole boards.* - To suit four pole boards.MCPBEB200Measurements:Millimetres (mm) unless stated otherwiseOutgoing Switchgear:Supplied separatelyOutgoing MCCB’s:Upto 250A TP and 200A SPMCCB PANELBOARDS - 250A BUSBAR 36KA ICCCAT. NO. H W DMCPBEB200 200 900 170MCPBEB300 300 900 170CAT. NO. (LEFT SIDE) CAT. NO. (RIGHT SIDE) H W DMCPCB22L MCPCB22R 200 200 170MCPCB32L MCPCB32R 300 200 170MCPCB24L MCPCB24R 200 400 170MCPCB34L MCPCB34R 300 400 170NO. of METER POSITIONSCAT. NO. (LEFT SIDE) CAT. NO. (RIGHT SIDE) H W D2 MCPMB32L MCPMB32R 500 400 1703 MCPMB52L MCPMB52R 700 400 1704 MCPMB72L MCPMB72R 700 400 1706 MCPMB112L MCPMB112R 950 400 1708 MCPMB152L MCPMB152R 1300 400 1709 MCPMB172L MCPMB172R 1300 400 1702 MCPMB42FL* MCPMB42FR* 1000 400 1703 MCPMB62FL* MCPMB62FR* 1200 400 1704 MCPMB82FL* MCPMB82FR* 1200 400 1706 MCPMB122FL* MCPMB122FR* 1450 400 1708 MCPMB162FL* MCPMB162FR* 1800 400 1709 MCPMB182FL* MCPMB182FR* 1300 400 170CAT. NO. (LEFT SIDE) CAT. NO. (RIGHT SIDE) H W DMCPEB32L MCPEB32R 500 200 170MCPEB52L MCPEB52R 700 200 170MCPEB72L MCPEB72R 700 200 170MCPEB112L MCPEB112R 950 200 170MCPEB152L MCPEB152R 1300 200 170MCPEB172L MCPEB172R 1300 200 170MCPEB42FL* MCPEB42FR* 1000 200 170MCPEB62FL* MCPEB62FR* 1200 200 170MCPEB82FL* MCPEB82FR* 1200 200 170MCPEB122FL* MCPEB122FR* 1450 200 170MCPEB162FL* MCPEB162FR* 1800 200 170MCPEB182FL* MCPEB182FR* 1800 200 170MC Range MCCB PanelboardsMCPEB32L3 POLE4 POLE3 POLE4 POLE3 POLE4 POLE3 POLEBottom extension boxes can also be used as a top extension box
12PROTEUS INDUSTRIAL | • Available from 4 to 18 triple pole outgoing ways.• Factory fitted incoming MCCB/isolator up to 400A 3/4 pole.• Ample cabling space for incoming cables.• Space next to incomer for metering, earth leakage protection and surge protection to monitor and protect whole board.• Range of side extension boxes, side metering boxes, bottom extension boxes and corner boxes MCCB PANELBOARDS - 400A BUSBAR 36KA ICCMCP44/I315MCP84/I400S315A MCCB INCOMER FITTED BOARDS(S) - Add suffix ‘S’ for Switch Disconnector Incomer option e.g. MCP84/I400S. Triple pole only400A MCCB INCOMER OR SWITCH DISCONNECTOR FITTED BOARDSMC Range MCCB PanelboardsMeasurements:Millimetres (mm) unless stated otherwiseOutgoing Switchgear:Supplied separatelyOutgoing MCCB’s:Upto 250A TP and 200A SPFEATURES:NO. of O/G WAYSCAT. NO. 3 POLE CAT. NO. 4 POLE H W D4 MCP44/I315 MCP44/I315F 1300 900 1706 MCP64/I315 MCP64/I315F 1500 900 1708 MCP84/I315 MCP84/I315F 1500 900 17012 MCP124/I315 MCP124/I315F 1750 900 17016 MCP164/I315 MCP164/I315F 2100 900 17018 MCP184/I315 MCP184/I315F 2100 900 170WALLMOUNTEDSIDEHINGEDDOORNO. of O/G WAYSCAT. NO. 3 POLE CAT. NO. 4 POLE H W D4 MCP44/I400 (S) MCP44/I400F 1300 900 1706 MCP64/I400 (S) MCP64/I400F 1500 900 1708 MCP84/I400 (S) MCP84/I400F 1500 900 17012 MCP124/I400 (S) MCP124/I400F 1750 900 17016 MCP164/I400 (S) MCP164/I400F 2100 900 17018 MCP184/I400 (S) MCP184/I400F 2100 900 170to suit 400A range of MC panels.• Bottom extension boxes are available in 200 or 300 mm heights as standard.• Side extension and meter extension boxes are available in left/right hand versions sized to suit all 400A range MC panels.• Corner boxes available when using side and bottom extension boxes to give a clean look.• Meters, SPDs and Earth Leakage Units are also available.WALLMOUNTEDSIDEHINGEDDOOR
13 | PROTEUS INDUSTRIALPROTEUS INDUSTRIALBottom extension boxes can also be used as a top extension boxMCPEB64LSIDE EXTENSION BOX SIDE METER EXTENSION BOX MCPMB84RMCCB PANELBOARDS - 400A BUSBAR 36KA ICCMC Range MCCB PanelboardsMeasurements:Millimetres (mm) unless stated otherwiseOutgoing Switchgear:Supplied separatelyOutgoing MCCB’s:Upto 250A TP and 200A SPBOTTOM EXTENSION BOX CORNER EXTENSION BOX MCPCB34LMCPBEB200CAT. NO. H W DMCPBEB200 200 900 170MCPBEB300 300 900 170CAT. NO. (LEFT SIDE) CAT. NO. (RIGHT SIDE) H W DMCPCB22L MCPCB22R 200 200 170MCPCB32L MCPCB32R 300 200 170MCPCB24L MCPCB24R 200 400 170MCPCB34L MCPCB34R 300 400 170CAT. NO. (LEFT SIDE) CAT. NO. (RIGHT SIDE) H W DMCPEB44L MCPEB44R 1300 200 170MCPEB64L MCPEB64R 1500 200 170MCPEB84L MCPEB84R 1500 200 170MCPEB124L MCPEB124R 1750 200 170MCPEB164L MCPEB164R 2100 200 170MCPEB184L MCPEB184R 2100 200 170NO. of METER POSITIONCAT. NO. (LEFT SIDE) CAT. NO. (RIGHT SIDE) H W D2 MCPMB44L MCPMB44R 1300 400 1703 MCPMB64L MCPMB64R 1500 400 1704 MCPMB84L MCPMB84R 1500 400 1706 MCPMB124L MCPMB124R 1750 400 1708 MCPMB164L MCPMB164R 2100 400 1709 MCPMB184L MCPMB184R 2100 400 170
14PROTEUS INDUSTRIAL | MC Range MCCB PanelboardsMCCB PANELBOARDS - 800A BUSBAR 36KA ICCMCP48/I500500A MCCB INCOMER FITTED BOARDS(S) - Add suffix ‘S’ for Switch Disconnector Incomer option e.g. MCP88/I630S. Triple pole only630A MCCB INCOMER OR SWITCH DISCONNECTOR FITTED BOARDS(S) - Add suffix ‘S’ for Switch Disconnector Incomer option e.g. MCP88/I800S. Triple pole only800A MCCB INCOMER OR SWITCH DISCONNECTOR FITTED BOARDSMCP48/I630SMCP128/I800F• Available from 4 to 18 triple pole outgoing ways.• Factory fitted incoming MCCB/isolator up to 800A 3/4 pole.• Ample cabling space for incoming cables.• Space next to incomer for metering, earth leakage protection and surge protection to monitor and protect whole board.• Range of side extension boxes, side metering boxes, bottom extension boxes and corner boxes Measurements:Millimetres (mm) unless stated otherwiseOutgoing Switchgear:Supplied separatelyOutgoing MCCB’s:Upto 250A TP and 200A SPFEATURES:to suit 800A range of MC panels.• Bottom extension boxes are available in 200 or 300 mm heights as standard.• Side extension and meter extension boxes are available in left/right hand versions sized to suit all 800A range MC panels.• Corner boxes available when using side and bottom extension boxes to give a clean look.• Meters, SPDs and Earth Leakage Units are also available.NO. of O/G WAYSCAT. NO. 3 POLE CAT. NO. 4 POLE H W D4 MCP48/I500 MCP48/I500F 1450 900 1706 MCP68/I500 MCP68/I500F 1650 900 1708 MCP88/I500 MCP88/I500F 1650 900 17012 MCP128/I500 MCP128/I500F 1900 900 17016 MCP168/I500 MCP168/I500F 2250 900 17018 MCP188/I500 MCP188/I500F 2250 900 170NO. of O/G WAYSCAT. NO. 3 POLE CAT. NO. 4 POLE H W D4 MCP48/I630 (S) MCP48/I630F 1450 900 1706 MCP68/I630 (S) MCP68/I630F 1650 900 1708 MCP88/I630 (S) MCP88/I630F 1650 900 17012 MCP128/I630 (S) MCP128/I630F 1900 900 17016 MCP168/I630 (S) MCP168/I630F 2250 900 17018 MCP188/I630 (S) MCP188/I630F 2250 900 170NO. of O/G WAYSCAT. NO. 3 POLE CAT. NO. 4 POLE H W D4 MCP48/I800 (S) MCP48/I800F 1450 900 1706 MCP68/I800 (S) MCP68/I800F 1650 900 1708 MCP88/I800 (S) MCP88/I800F 1650 900 17012 MCP128/I800 (S) MCP128/I800F 1900 900 17016 MCP168/I800 (S) MCP168/I800F 2250 900 17018 MCP188/I800 (S) MCP188/I800F 2250 900 170WALLMOUNTEDSIDEHINGEDDOORWALLMOUNTEDSIDEHINGEDDOORWALLMOUNTEDSIDEHINGEDDOOR
15 | PROTEUS INDUSTRIALPROTEUS INDUSTRIALMC Range MCCB PanelboardsMCCB PANELBOARDS - 800A BUSBAR 36KA ICCMeasurements:Millimetres (mm) unless stated otherwiseOutgoing Switchgear:Supplied separatelyOutgoing MCCB’s:Upto 250A TP and 200A SPMCPEB68LSIDE EXTENSION BOX SIDE METER EXTENSION BOX BOTTOM EXTENSION BOX CORNER EXTENSION BOX MCPCB34LMCPBEB200CAT. NO. H W DMCPBEB200 200 900 170MCPBEB300 300 900 170CAT. NO. (LEFT SIDE) CAT. NO. (RIGHT SIDE) H W DMCPCB22L MCPCB22R 200 200 170MCPCB32L MCPCB32R 300 200 170MCPCB24L MCPCB24R 200 400 170MCPCB34L MCPCB34R 300 400 170CAT. NO. (LEFT SIDE) CAT. NO. (RIGHT SIDE) H W DMCPEB48L MCPEB48R 1450 200 170MCPEB68L MCPEB68R 1650 200 170MCPEB88L MCPEB88R 1650 200 170MCPEB128L MCPEB128R 1900 200 170MCPEB168L MCPEB168R 2250 200 170MCPEB188L MCPEB188R 2250 200 170NO. of METER POSITIONCAT. NO. (LEFT SIDE) CAT. NO. (RIGHT SIDE) H W D2 MCPMB48L MCPMB48R 1450 400 1703 MCPMB68L MCPMB68R 1650 400 1704 MCPMB88L MCPMB88R 1650 400 1706 MCPMB128L MCPMB128R 1900 400 1708 MCPMB168L MCPMB168R 2250 400 1709 MCPMB188L MCPMB188R 2250 400 170Bottom extension boxes can also be used as a top extension boxMCPMB48R
16PROTEUS INDUSTRIAL | METERINGNON-TARIFF MULTIFUNCTION MULTIMETERS (1 & 3 PHASE) Fitted adjacent to main incomer to monitor total panelboard power usage.No meter extension box required.MID/TARIFF MULTIMETERS (1 & 3 PHASE) To be fitted adjacent to main incomer to monitor total panelboard power usage. No meter extension box required.To be fitted in meter extension boxes to monitor outgoing / incoming circuits up to 250A. e.g.6 way panelboard c/w 400A TP MCCB incomer (MCP64/I400).Compatible meter extension boxes could be fitted on left (MCPMB64L) or right (MCPMB64R). Associated switchgear could be 6 x 100A TP MCCBs (MC100T) and 6 x Digital multimeters (MCPMFM100T).To be fitted in meter extension boxes to monitor outgoing / incoming circuits up to 250A. e.g.6 way panelboard c/w 400A TP MCCB incomer (MCP64/I400). Compatible meter extension boxes could be fitted on left (MCPMB64L) or right (MCPMB64R). Associated switchgear could be 6 x 125A TP MCCBs (MC125T) and 6 x digital multimeters (MCPMFM125TMID).MCPMFM063TMIDMeasurements:Millimetres (mm) unless stated otherwiseMC Range MCCB PanelboardsAMPERAGE CAT. NO. (3 PHASE) CAT. NO. (1 PHASE)63A MCPMFM063T MCPMFM063S100A MCPMFM100T MCPMFM100S125A MCPMFM125T MCPMFM125S160A MCPMFM160T MCPMFM160S200A MCPMFM200T MCPMFM200S250A MCPMFM250T -AMPERAGE CAT. NO. (3 PHASE)315A MCPMFM315T400A MCPMFM400T500A MCPMFM500T630A MCPMFM630T800A MCPMFM800TNON-TARIFF MULTIFUNCTION MULTIMETERS AMPERAGE CAT. NO. (3 PHASE)315A MCPMFM315TMID400A MCPMFM400TMID500A MCPMFM500TMID630A MCPMFM630TMID800A MCPMFM800TMIDMID/TARIFF MULTIMETERS (1 & 3 PHASE) AMPERAGE CAT. NO. (3 PHASE) CAT. NO. (1 PHASE)63A MCPMFM063TMID MCPMFM063SMID100A MCPMFM100TMID MCPMFM100SMID125A MCPMFM125TMID MCPMFM125SMID160A MCPMFM160TMID MCPMFM160SMID200A MCPMFM200TMID MCPMFM200SMID250A MCPMFM250TMID -• Tariff and non tariff multifunction meters.• Fitting into side meter boxes for outgoing devices or 250A TP incomers.• Fitted next to incomer on 250A 4P, 400A and 800A panelboards.FEATURES:Tariff or MID approved meters are used in situations where it is necessary to charge clients in a Landlord – Tenant type arrangement. The landlord uses the individual meters to charge clients for their energy usage. These meters have a higher accuracy class than Non-Tariff meters.Non-Tariff (check) meters are used in situations where the electricity bill is apportioned to different departments within a company but there is only one company paying the bill.MCPMFM315TMCPMFM315MIDMCPMFM063T
17 | PROTEUS INDUSTRIALPROTEUS INDUSTRIALEARTH LEAKAGE UNITS To be fitted in meter extension boxes to monitor outgoing / incoming circuits earth leakage up to 250A. e.g.6 way panelboard c/w 400A TP MCCB incomer (MCP64/I400). Compatible meter extension boxes could be fitted on left (MCPMB64L) or right (MCPMB64R). Associated switchgear could be 6 x 100A TP MCCBs (MC100T) and 6 x Earth Leakage Units (MCPEL100).• It is intended that the earth leakage units are under the supervision of instructed or skilled persons.• Earth leakage relay has adjustable trip current and time settings.STAND ALONE EARTH LEAKAGE UNITS CT internal diameters of 70 mm from 100A to 200A and 120 mm for current ratings from 250A to 630A.MCEL200TACCESSORIESFitted adjacent to main incomer to monitor total panelboard earth leakage. No meter extension box required.MCPEL100• The MCCB is tripped via its integral shunt trip coil.• The full breaking capacity of the MCCB is retained.• Type A filtering.IP3X ENCLOSED MCCBSMCE100TMeasurements:Millimetres (mm) unless stated otherwiseMC Range MCCB PanelboardsFEATURES:AMPERAGE CAT. NO.100A MCPEL100125A MCPEL125160A MCPEL160200A MCPEL200250A MCPEL250AMPERAGE CAT. NO.400A MCPEL400630A MCPEL630AMPERAGE CAT. NO. (3 POLE+N)CAT. NO. (4 POLE)MIN. SENSITIVITY AMPSH W D100A MCEL100T MCEL100F 0.03 700 300 170125A MCEL125T MCEL125F 0.03 700 300 170160A MCEL160T MCEL160F 0.03 700 300 170200A MCEL200T MCEL200F 0.03 700 300 170250A MCEL250T MCEL250F 0.1 950 400 170315A MCEL315T MCEL315F 0.1 950 400 170400A MCEL400T MCEL400F 0.1 950 400 170500A MCEL500T MCEL500F 0.1 950 400 170630A MCEL630T MCEL630F 0.1 950 400 170Triple Pole 36kA Moulded Case Circuit Breaker in Steel Enclosure fitted with Earth Fault Relay DeviceAMPERAGE CAT. NO. (3 POLE) CAT. NO. (4 POLE) H W D63A MCE063T MCE063F 400 300 17080A MCE080T - 400 300 170100A MCE100T MCE100F 400 300 170125A MCE125T MCE125F 700 300 170160A MCE160T MCE160F 700 300 170200A MCE200T MCE200F 700 300 170250A MCE250T MCE250F 950 400 170315A MCE315T MCE315F 950 400 170400A MCE400T MCE400F 950 400 170500A MCE500T MCE500F 950 400 170630A MCE630T MCE630F 950 400 170800A MCE800T MCE800F 1300 500 300Triple Pole 36kA Moulded Case Circuit Breaker in IP3X Steel Enclosures
18PROTEUS INDUSTRIAL | SURGE PROTECTION DEVICES 3 PHASE + N (4 POLE)ENCLOSURES TO SUIT INDIVIDUAL MCCBS (3 & 4 POLE) MCENC13 pole units will accept 1 x SP or 1 x TP MCCB. 4 pole units will accept 1 x 4P MCCB only. When fitting a SP MCCB, 2 blanking modules (MCCBM1) will also need to be installed.250A MCCB must be large frame size MCCB (MC250TLF, MC250FLF).SHUNT TRIP UNITS MCST4P630ACCESSORIESMCA3P250 - Auxiliary contact for MC016T to MC250T. Wire in series with shunt trip MCST3P250. * - For MC250TLF use S/T MCST3P630. ** - For MC250FLF use MCST4P400 Measurements:Millimetres (mm) unless stated otherwiseMC Range MCCB PanelboardsAMPERAGE 3 POLE CAT. NO.4 POLE CAT. NO.H W D16A - 100A MCENC1 MCENC1F 400 300 170125A - 200A MCENC2 MCENC2F 700 300 170250A - 630A MCENC6 MCENC6F 950 400 170800A MCENC8 MCENC8F 1300 500 300DESCRIPTION CAT. NO. VOLTAGE DEVICEFor MCCB up to 250A MCST3P250* 220V 3+4 poleFor MCCB 315A-630A MCST3P630 220V 3 poleFor MCCB 800A MCST3P800 220V 3 poleFor MCCB up to 100A MCST4P100 220V 4 poleFor MCCB 315A-400A MCST4P400** 220V 4 poleFor MCCB 500A-630A MCST4P630 220V 4 poleFor MCCB 800A MCST4P800 220V 4 pole220VOLTSINCOMER AMPERAGEINCOMER POLES TYPE PROTECTIVE DEVICE CAT. NO. H W D≤250A 3 Type 1+2 125A TP MCCB MCPT12/250 300 900 170≤250A 3 Type 2 125A TP MCCB MCPT2/250 300 900 170≤250A 4 Type 1+2 125A TP MCCB MCPT12/250FFitted adjacent to incomer≤250A 4 Type 2 125A TP MCCB MCPT2/250F>315 - 800A 3 & 4 Type 1+2 250A TP MCCB MCPT12/800>315 - 800A 3 & 4 Type 2 250A TP MCCB MCPT2/800For 250A TP incomer boards, the SPD will be fitted in the included 300 mm bottom extension box. Type 1+2 and Type 2 device kits include a 125A TP MCCB to be fitted into board taking an outgoing way to feed SPD.For 250A 4P incomer boards, the SPD will be fitted adjacent to the incoming device. Type 1+2 and Type 2 device kits include a 125A TP MCCB to be fitted into board taking an outgoing way to feed SPD.For 315 - 800A TP and 4P incomer boards, the SPD will be fitted adjacent to the incoming device. Kits include a 250A TP MCCB to be fitted into board taking an outgoing way to feed SPD.Type 1: Protection against the effects of lightning.Type 2: Protection against the effects of man-made surges on the mains supply system.MCP84/I400 & MCPT12/800(Blanks sold separately)For surge protection Info, SPD selection chart, loose surge arrestors and enclosed surge arrestors please go to pages 57, 58 & 59SURGE PROTECTION DEVICES
19 | PROTEUS INDUSTRIALPROTEUS INDUSTRIAL900mm200mm 400mm800mm300mm 700mmMCPBEB300 MCPCB34RMCPCB32LMCPEB64L MCPMB64RMC400TSPDMCPEL400Core Bal. CTMCP64/I400ENENMCPMFM400TMC250T900mm200mm 400mm700mm200mmMCPBEB200 MCPCB24RMCPCB22LMCPEB52L MCPMB52RMCP52/I250E EN NADDITIONAL ACCESSORIES MCCBM1250A BUSBAR SYSTEM400A AND 800A BUSBAR SYSTEMSGENERAL ARRANGEMENTS** - 800 mm height only up to 400A incomer. 950 mm 500A - 800A. Depth 170 mm/215 mm over door.MCNUTM8Measurements:Millimetres (mm) unless stated otherwiseMC Range MCCB PanelboardsDESCRIPTION CAT. NO.Padlocking device - for 3P & adj 4P MCCBs (16A to 630A) MCPDSP MCCB blank MCCBM1Incomer door MCPID120 mm2 lug connection kit for MC016T-MC250T MCLK120150 mm2 lug connection kit for MC016T-MC250T MCLK150185 mm2 lug connection kit for MC016T-MC250T MCLK185MC063T-MC250T long terminal shield MCLTSM8 nut insert and bolt for MC016T-MC250T MCNUTM8Key lock for door XLKL
20PROTEUS INDUSTRIAL | MCCB FEATURESThe moulded case circuit breakers are housed in fibre reinforced thermoset polyester that combines ruggedness, high dielectric and mechanical strength.High quality silver alloy contacts (with elements of tungsten and graphite) ensure both high conductivity at point contact and minimal pitting during switching for a longer contact life.Positive contact indication is by means of the operating lever position.KEYFEATURES:MOULDED CASE CIRCUIT BREAKERS BS EN 60947 1-2FEATURES:Moulded Case Circuit Breakers
21 | PROTEUS INDUSTRIALPROTEUS INDUSTRIALMCCB FEATURESFull technical detail, markings and adjustable parameters clearly identified.Box clamp terminals for connection of cables upto 120 mm2 (upto MC250T).Phase BarriersPhase barriers supplied with lug connected MCCBs.OFFERING A COMPREHENSIVE RANGE1.1.Technical DetailTechnical Detail2.Box Clamp Terminals2.Box Clamp TerminalsFully shrouded terminals.3.Fully Shrouded Terminals4.Trip PositionMid-trip position of MCCB dolly.4.Trip Position3.Fully Shrouded Terminals5.Moulded Case Circuit Breakers
22PROTEUS INDUSTRIAL | MCCBMeasurements:Millimetres (mm) unless stated otherwiseMoulded Case Circuit BreakersMC032TMC125SSINGLE POLE MCCBS• The moulded case circuit breakers are housed in fibre reinforced thermoset polyester that combines ruggedness, high dielectric and mechanical strength.** - For panel boards only.• High quality silver alloy contacts (with elements of tungsten and graphite) ensure both high conductivity at point contact and minimal pitting during switching for a longer contact life.• Positive contact indication is by means of the operating lever position.MC100TMRMOTOR RATED MCCBSFEATURES:Single Pole 36kA Moulded Case Circuit BreakersTRIPLE POLE MCCBSTriple Pole 36kA Moulded Case Circuit BreakersCURRENT RATING (A)NO. of POLESkA RATING(kA)THERMAL RELEASEMAGNETIC RELEASETERMINAL CAPACITYCAT. NO.16 SP 36 F 500A 120 mm2MC016S 20 SP 36 F 500A 120 mm2MC020S 25 SP 36 F 500A 120 mm2MC025S 32 SP 36 F 500A 120 mm2MC032S 40 SP 36 F 500A 120 mm2MC040S 50 SP 36 F 500A 120 mm2MC050S 63 SP 36 F 500A 120 mm2MC063S 80 SP 36 F 800A 120 mm2MC080S 100 SP 36 F 1000A 120 mm2MC100S 125 SP 36 F 1250A 120 mm2MC125S 160 SP 36 F 1600A 120 mm2MC160S 200 SP 36 F 2000A 120 mm2MC200S CURRENT RATING (A)NO. of POLESkA RATING(kA)THERMAL RELEASEMAGNETIC RELEASETERMINAL CAPACITYCAT. NO.16 TP 36 A (0.8-1xIn) 250A 120 mm2MC016T 20 TP 36 A (0.8-1xIn) 250A 120 mm2MC020T 25 TP 36 A (0.8-1xIn) 250A 120 mm2MC025T 32 TP 36 A (0.8-1xIn) 320A 120 mm2MC032T 40 TP 36 A (0.8-1xIn) 400A 120 mm2MC040T 50 TP 36 A (0.8-1xIn) 500A 120 mm2MC050T 63 TP 36 A (0.8-1xIn) 630A 120 mm2MC063T 80 TP 36 A (0.8-1xIn) 800A 120 mm2MC080T 100 TP 36 A (0.8-1xIn) 1000A 120 mm2MC100T 125 TP 36 A (0.8-1xIn) 1250A 120 mm2MC125T 160 TP 36 A (0.8-1xIn) 1600A 120 mm2MC160T 200 TP 36 A (0.8-1xIn) A (5-10xIn) 120 mm2MC200T 250 TP 36 A (0.8-1xIn) A (5-10xIn) 120 mm2MC250T** MOTOR RATING KW (APPROX.)MCCB AMPSkA RATING(kA)THERMAL RELEASEMAGNETIC RELEASETERMINAL CAPACITYCAT. NO.30 63A 36 A (0.7-1x In) 15xIn 120 mm2MC063TMR 37 80A 36 A (0.7-1x In) 15xIn 120 mm2MC080TMR 51 100A 36 A (0.7-1x In) 15xIn 120 mm2MC100TMR 63 125A 36 A (0.7-1x In) 15xIn 120 mm2MC125TMR 80 160A 36 A (0.7-1x In) 15xIn 120 mm2MC160TMR 90 200A 36 A (0.7-1x In) 10-15xIn 120 mm2MC200TMR 110 250A 36 A (0.7-1x In) 10-15xIn 120 mm2MC250TMR** Triple Pole 36kA Motor Rated Moulded Case Circuit Breakers F - Fixed | A - Adjustable| LF - Large frame.** - For panel boards only.
23 | PROTEUS INDUSTRIALPROTEUS INDUSTRIALMCCBMeasurements:Millimetres (mm) unless stated otherwiseMoulded Case Circuit Breakers Large Frame TP MCCBs can not be fitted as an outgoing device.MC250TLF must be used when using as an individual cable in, cable out MCCB device. *** - This MCCB does not fit in MCP panelboards.MC250TLFMC800FFOUR POLE MCCBSTRIPLE POLE NON-AUTO MCCBSMC250TNA4 Pole MCCBs cannot be fitted as outgoing devices in MCP panelboards.MC250FALF must be used when using as an individual cable in, cable out MCCB device.CURRENT RATING (A)NO. of POLESkA RATING(kA)THERMAL RELEASEMAGNETIC RELEASETERMINAL CAPACITYCAT. NO.250 TP 36 A (0.8-1xIn) A (5-10xIn) Lugged(M12) MC250TLF315 TP 36 A (0.8-1xIn) A (4-8xIn) Lugged(M12) MC315T400 TP 36 A (0.8-1xIn) A (4-8xIn) Lugged(M12) MC400T500 TP 36 A (0.8-1xIn) A (4-8xIn) Lugged(M12) MC500T630 TP 36 A (0.8-1xIn) A (4-8xIn) Lugged(M12) MC630T 800 TP 36 A (0.8-1xIn) A (4-8xIn) Lugged(M12) MC800T1000 TP 70 A (0.4-1xIn) A (2-10xIn) Lugged MC1000T***1250 TP 70 A (0.4-1xIn) A (2-10xIn) Lugged MC1250T***1600 TP 70 A (0.4-1xIn) A (2-10xIn) Lugged MC1600T***Large Frame Triple Pole 36 - 70kA Moulded Case Circuit BreakersLARGE FRAME TRIPLE POLE MCCBSCURRENT RATING (A)NO. of POLESkA RATING(kA)THERMAL RELEASEMAGNETIC RELEASETERMINAL CAPACITYCAT. NO.63 FP 36 A 0-8-1 630 Tunnel-120mm2MC063FA 100 FP 36 A 0-8-1 1000 Tunnel-120mm2MC100FA 125 FP 36 A 0-8-1 1250 Tunnel-120mm2MC125FA 160 FP 36 A 0-8-1 1600 Tunnel-120mm2MC160FA 200 FP 36 A 0-8-1 5-10X Tunnel-120mm2MC200FA 250 FP 36 A 0-8-1 5-10X Tunnel-120mm2MC250FA 250 FP 50 A 0-8-1 5-10X Lugged(M12) MC250FALF 315 FP 50 A 0-8-1 5-10X Lugged(M12) MC315FA 400 FP 50 A 0-8-1 5-10X Lugged(M12) MC400FA 500 FP 50 A 0-8-1 5-10X Lugged(M12) MC500FA 630 FP 50 A 0-8-1 5-10X Lugged(M12) MC630FA 800 FP 36 F 800A A (8-10xIn) Lugged(M12) MC800FFour Pole 36 - 50kA Moulded Case Circuit BreakersCURRENT RATING (A)NO. of POLESkA* RATING(kA)THERMAL RELEASEMAGNETIC RELEASETERMINAL CAPACITYCAT. NO.200 TP 36 - - Tunnel-120mm2MC200TNA250 TP 36 - - Tunnel-120mm2MC250TNA400 TP 36 - - Lugged(M12) MC400TNA630 TP 36 - - Lugged(M12) MC630TNA800 TP 36 - - Lugged(M12) MC800TNA*Non-Auto MCCBs should be protected by a Proteus MC..T/F MCCB of the same rating.Non-Auto MCCBs cannot be fitted as outgoing devices in MCP panelboards. F - Fixed | A - Adjustable | LF - Large frame.
24PROTEUS INDUSTRIAL | MCX 3-PHASE DISTRIBUTION BOARDS200A MCB/MCCB DISTRIBUTION BOARDSMCX22/I200250A MCB/MCCB DISTRIBUTION BOARDSMCX22/I250• The MCX range ‘combination board’ brings together the standard TP&N MCB distribution board with typical 17.5 mm module MCBs with the opportunity to fit larger amperage MCCBs upto 160A.• Accepts MCBs up to 63A and RCBOs up to 45A (17.5 mm wide module).• Accepts MCCBs 16A to 160A • Isolator incomer fitted as standard.• Manufactured to BSEN 61439 - Part 1 & 3.Measurements:Millimetres (mm) unless stated otherwiseOutgoing Switchgear:Supplied separatelyCircuit Protection Devices:Please refer to page 22 & 52MCX 3-Phase Distribution BoardsFEATURES:INCOMER FACTORY FITTEDNO. of O/G WAYS CAT. NO. H W D200A TP Isolator 2 W-63A, 2 W-160A MCX22/I200 950 600 170200A TP Isolator 2 W-63A, 4 W-160A MCX24/I200 1100 600 170200A TP Isolator 4 W-63A, 2 W-160A MCX42/I200 1000 600 170200A TP Isolator 4 W-63A, 4 W-160A MCX44/I200 1100 600 170200A TP Isolator 6 W-63A, 2 W-160A MCX62/I200 1100 600 170200A TP Isolator 6 W-63A, 4 W-160A MCX64/I200 1200 600 170200A TP Isolator 8 W-63A, 2 W-160A MCX82/I200 1100 600 170200A TP Isolator 8 W-63A, 4 W-160A MCX84/I200 1200 600 170200A TP Isolator 12 W-63A, 2 W-160A MCX122/I200 1200 600 170200A TP Isolator 12 W-63A, 4 W-160A MCX124/I200 1300 600 170MCX range offers versatile use of standard MCBs upto 63A, RCBOs upto 45A and MCCBs upto 160A. INCOMER FACTORY FITTEDNO. of O/G WAYS CAT. NO. H W D250A TP Isolator 2 W-63A, 2 W-160A MCX22/I250 950 600 170250A TP Isolator 2 W-63A, 4 W-160A MCX24/I250 1100 600 170250A TP Isolator 4 W-63A, 2 W-160A MCX42/I250 1000 600 170250A TP Isolator 4 W-63A, 4 W-160A MCX44/I250 1100 600 170250A TP Isolator 6 W-63A, 2 W-160A MCX62/I250 1100 600 170250A TP Isolator 6 W-63A, 4 W-160A MCX64/I250 1200 600 170250A TP Isolator 8 W-63A, 2 W-160A MCX82/I250 1100 600 170250A TP Isolator 8 W-63A, 4 W-160A MCX84/I250 1200 600 170250A TP Isolator 12 W-63A, 2 W-160A MCX122/I250 1200 600 170250A TP Isolator 12 W-63A, 4 W-160A MCX124/I250 1300 600 170MCX range offers versatile use of standard MCBs upto 63A, RCBOs upto 45A and MCCBs upto 160A.
25 | PROTEUS INDUSTRIALPROTEUS INDUSTRIALCBX 3-PHASE DISTRIBUTION BOARDSCBX 3-Phase Distribution BoardsDESCRIPTION CAT. NO. H W D80-125 SP CBENCSP 385 205 11680-125 TP CBENCTP 385 205 116• The CBX range ‘combination board’ brings together the standard TP&N MCB distribution board with typical 17.5 mm module MCBs with the opportunity to fit larger amperage MCBs upto 125A rated.200A MCB DISTRIBUTION BOARDSCBX22/I200• Accepts MCBs up to 63A and RCBOs up to 45A (17.5 mm wide module).• Accepts MCBs 80A to 125A (26.3 mm wide module).• Isolator incomer fitted as standard.• Manufactured to BSEN 61439 - Part 1 & 3.250A MCB DISTRIBUTION BOARDSCBX24/I250LARGE FRAME TYPE C MCBLARGE FRAME MCB IP3X STEEL ENCLOSURESCB125T/CCBENCTPMeasurements:Millimetres (mm) unless stated otherwiseOutgoing Switchgear:Supplied separatelyCircuit Protection Devices:Please refer to page 52FEATURES:INCOMER FACTORY FITTEDNO. of O/G WAYS CAT. NO. H W D200A TP Isolator 2 W-63A, 2 W-125A CBX22/I200 950 600 170200A TP Isolator 2 W-63A, 4 W-125A CBX24/I200 1100 600 170200A TP Isolator 4 W-63A, 2 W-125A CBX42/I200 1000 600 170200A TP Isolator 4 W-63A, 4 W-125A CBX44/I200 1100 600 170200A TP Isolator 6 W-63A, 2 W-125A CBX62/I200 1100 600 170200A TP Isolator 6 W-63A, 4 W-125A CBX64/I200 1200 600 170200A TP Isolator 8 W-63A, 2 W-125A CBX82/I200 1100 600 170200A TP Isolator 8 W-63A, 4 W-125A CBX84/I200 1200 600 170200A TP Isolator 12 W-63A, 2 W-125A CBX122/I200 1200 600 170200A TP Isolator 12 W-63A, 4 W-125A CBX124/I200 1300 600 170CBX range offers versatile use of standard size MCB's upto 63A, RCBO's upto 45A and larger frame size MCB's 80A to 125AINCOMER FACTORY FITTEDNO. of O/G WAYS CAT. NO. H W D250A TP Isolator 2 W-63A, 2 W-125A CBX22/I250 950 600 170250A TP Isolator 2 W-63A, 4 W-125A CBX24/I250 1100 600 170250A TP Isolator 4 W-63A, 2 W-125A CBX42/I250 1000 600 170250A TP Isolator 4 W-63A, 4 W-125A CBX44/I250 1100 600 170250A TP Isolator 6 W-63A, 2 W-125A CBX62/I250 1100 600 170250A TP Isolator 6 W-63A, 4 W-125A CBX64/I250 1200 600 170250A TP Isolator 8 W-63A, 2 W-125A CBX82/I250 1100 600 170250A TP Isolator 8 W-63A, 4 W-125A CBX84/I250 1200 600 170250A TP Isolator 12 W-63A, 2 W-125A CBX122/I250 1200 600 170250A TP Isolator 12 W-63A, 4 W-125A CBX124/I250 1300 600 170CBX range offers versatile use of standard size MCB's upto 63A, RCBO's upto 45A and larger frame size MCB's 80A to 125ADESCRIPTION kA RATING CAT. NO.80A SP 10 CB080S/C80A TP 10 CB080T/C100A SP 10 CB100S/C100A TP 10 CB100T/C125A SP 10 CB125S/C125A TP 10 CB125T/CDESCRIPTION CAT. NO.Key lock for door XLKLCB MCB padlock device DLPX1LOCKINGXLKL
26PROTEUS INDUSTRIAL | XL RANGE FITTED WITH SURGE PROTECTIONProteus Switchgear offers a comprehensive range of Lightning and Surge Protection Devices for single and three phase applications. Whether it’s a stand-alone device FEATURES:or a pre-assembled SPD in a distribution board, Proteus can provide a coordinated system to meet your specific requirements125A ISOLATOR INCOMER c/w TYPE 2 SPDNO. of O/G TP WAYS CAT. NO. TYPE 2 SPDH W D3 XL4S125T2 457 600 1325 XL6S125T2 512 600 1327 XL8S125T2 567 600 13211 XL12S125T2 732 600 13215 XL16S125T2 842 600 13219 XL20S125T2 942 600 13223 XL24S125T2 1217 600 132125A ISOLATOR INCOMER c/w TYPE 1+2 SPDNO. of O/G TP WAYS CAT. NO. TYPE 2 SPDH W D3 XL4S125T12 457 600 1325 XL6S125T12 512 600 1327 XL8S125T12 567 600 13211 XL12S125T12 732 600 13215 XL16S125T12 842 600 13219 XL20S125T12 942 600 13223 XL24S125T12 1217 600 132XL4S125T2 XL6S125T12200A ISOLATOR INCOMER c/w TYPE 2 SPDNO. of O/G TP WAYS CAT. NO. TYPE 2 SPDH W D3 XL4S2T2 732 600 1325 XL6S2T2 732 600 1327 XL8S2T2 732 600 13211 XL12S2T2 842 600 13215 XL16S2T2 942 600 13219 XL20S2T2 1217 600 13223 XL24S2T2 1217 600 132200A ISOLATOR INCOMER c/w TYPE 1+2 SPDNO. of O/G TP WAYS CAT. NO. TYPE 2 SPDH W D3 XL4S2T12 732 600 1325 XL6S2T12 732 600 1327 XL8S2T12 732 600 13211 XL12S2T12 842 600 13215 XL16S2T12 942 600 13219 XL20S2T12 1217 600 13223 XL24S2T12 1217 600 132XL8S2T2 XL12S2T12XL 3-Phase Distribution BoardsMeasurements:Millimetres (mm) unless stated otherwiseOutgoing Switchgear:Supplied separatelyFor surge protection Info, SPD selection chart, loose surge arrestors and enclosed surge arrestors please go to pages 57, 58 & 59SURGE PROTECTION DEVICES
27 | PROTEUS INDUSTRIALPROTEUS INDUSTRIAL• Available from 4 to 24 triple pole outgoing ways.• Accepts MCBs from 2A to 63A and RCBOs from 6A to 45A (17.5 mm wide module).• Key lock available for door (XLKL).• Dual Earth and Neutral terminal bars.• Removable gland plates top & bottom.• Manufactured to BSEN 61439 - Part 1 & 3.XL4S2THREE PHASE SPLIT LOAD DISTRIBUTION BOARDSFitted with a 100A 4pole 30 mA RCD as standard.XL84SLKEY LOCKXLKL125A ISOLATOR INCOMER DISTRIBUTION BOARDS200A ISOLATOR INCOMER DISTRIBUTION BOARDSXL8S125• The XL range of kWh metered boards and split load kWh metered boards, which can be used to meter lighting and power, have over 100% more cabling space than the standard equivalent three phase board. kWh meters are factory fitted to monitor the number of ways chosen to suit the application. Non-tariff as standard, tariff meter available on requestFEATURES:INCOMER FACTORY FITTEDNO. of O/G WAYS CAT. NO. H W D125A TP Isolator 4 XL4S125 457 600 132125A TP Isolator 6 XL6S125 512 600 132125A TP Isolator 8 XL8S125 567 600 132125A TP Isolator 12 XL12S125 732 600 132125A TP Isolator 16 XL16S125 842 600 132125A TP Isolator 20 XL20S125 942 600 132125A TP Isolator 24 XL24S125 1217 600 132INCOMER FACTORY FITTEDNO. of O/G WAYS CAT. NO. H W D200A TP Isolator 4 XL4S2 732 600 132200A TP Isolator 6 XL6S2 732 600 132200A TP Isolator 8 XL8S2 732 600 132200A TP Isolator 12 XL12S2 842 600 132200A TP Isolator 16 XL16S2 942 600 132200A TP Isolator 20 XL20S2 1217 600 132200A TP Isolator 24 XL24S2 1217 600 132INCOMER FACTORY FITTEDNO. of TP WAYS CAT. NO. H W DISOLATOR RCD100A TP Isolator 4 6 XL46SL 842 600 132100A TP Isolator 4 8 XL48SL 842 600 132100A TP Isolator 6 4 XL64SL 842 600 132100A TP Isolator 6 6 XL66SL 842 600 132100A TP Isolator 8 4 XL84SL 842 600 132DESCRIPTION CAT. NO. W DKey lock for door XLKL - -XL 3-Phase Distribution BoardsMeasurements:Millimetres (mm) unless stated otherwiseOutgoing Switchgear:Supplied separatelyXL 3-PHASE DISTRIBUTION BOARDS
28PROTEUS INDUSTRIAL | XL 3-PHASE DISTRIBUTION BOARDSMETERED DISTRIBUTION BOARDS c/w METERXL8S1MDAll above units are supplied complete with a 100A 4 pole incoming isolator as standard.SPLIT LOAD METERED DISTRIBUTION BOARDSXL68MDSPLIT LOAD METERED BOARD INCOMING ISOLATOR KITSEach individual XL distribution board unit with meter fitted must not exceed 100A full load current per phase. Select isolator incoming kit to satisfy the total load current demand.METERS & ENCLOSURESKWH2DMeasurements:Millimetres (mm) unless stated otherwiseOutgoing Switchgear:Supplied separatelyXL 3-Phase Distribution BoardsDESCRIPTION kWh METER CAT. NO. H W D4 way TP&N MCB Board Digital XL4S1MD 567 600 1326 way TP&N MCB Board Digital XL6S1MD 732 600 1328 way TP&N MCB Board Digital XL8S1MD 732 600 13212 way TP&N MCB Board Digital XL12S1MD 842 600 13216 way TP&N MCB Board Digital XL16S1MD 942 600 132TP METER WAYS (LIGHTING)TP METER WAYS (POWER)kWh METER CAT. NO. H W D4 6 Digital XL46MD 969 600 1326 8 Digital XL68MD 1079 600 1328 12 Digital XL812MD 1299 600 132Additional split load configurations available on request.DID YOU KNOW?DESCRIPTION CAT. NO. H W D125A 4 pole isolator incoming kit XLI125 400 600 132200A 4 pole isolator incoming kit XLI200 400 600 132DESCRIPTION kWh METER CAT. NO. H W D100A DP direct connect meter Digital KWH2D 90 75 73100A 4P direct connect meter Digital KWH4D 90 125 73100A DP meter enclosure only - KWH2E 383 235 125100A 4P meter enclosure only - KWH4E 383 235 125
29 | PROTEUS INDUSTRIALPROTEUS INDUSTRIALCASE STUDY:Halfords were previously purchasing pre-assembled, standard switch boards from an alternative overseas manufacturer, the design and lead time of which was becoming an issue and Halfords realised they required a more bespoke, future proof solution. HALFORDSSPECIAL DISTRIBUTION BOARDSFollowing contact with Proteus Industrial Switchgear of Telford, a site visit to an existing store was arranged where further design discussions were held with the installation electricians. The discussions resulted in the design of a distribution panel incorporating multiple mcb boards, contactors, time switches and emergency lighting test equipment which were all designed to meet their future requirements.An initial trial installation was successfully completed at the new Halfords store in Beckton. The Store Development Manager said, “with Proteus being a UK based manufacturer it was easy to discuss our requirements and make any changes as the design progressed. The end result was a more cost effective panel board with reduced supply and site installation time.”BESPOKE SOLUTIONSITE VISITSTECHNICAL SUPPORT FROM MANUFACTURERCase Study
30PROTEUS INDUSTRIAL | BX 3-Phase Distribution BoardsBX RANGE FITTED WITH SURGE PROTECTIONMeasurements:Millimetres (mm) unless stated otherwiseOutgoing Switchgear:Supplied separately125A ISOLATOR INCOMER c/w SPDProteus Switchgear offers a comprehensive range of Lightning and Surge Protection Devices for single and three phase applications. Whether it’s a stand-alone device FEATURES:or a pre-assembled SPD in a distribution board, Proteus can provide a coordinated system to meet your specific requirementsNO. of O/G TP WAYS CAT. NO. TYPE 2 SPDCAT. NO. TYPE 1+2 SPDH W D3 BX4S125T2 BX4S125T12 390 410 1105 BX6S125T2 BX6S125T12 442 410 1107 BX8S125T2 BX8S125T12 495 410 11011 BX12S125T2 BX12S125T12 600 410 11015 BX16S125T2 BX16S125T12 810 410 11019 BX20S125T2 BX20S125T12 1000 410 11023 BX24S125T2 BX24S125T12 1180 410 110BX6S125T12200A ISOLATOR INCOMER c/w SPDNO. of O/G TP WAYS CAT. NO. TYPE 2 SPDCAT. NO. TYPE 1+2 SPDH W D3 BX4S2T2 BX4S2T12 600 410 1105 BX6S2T2 BX6S2T12 600 410 1107 BX8S2T2 BX8S2T12 700 410 11011 BX12S2T2 BX12S2T12 810 410 11015 BX16S2T2 BX16S2T12 1000 410 11019 BX20S2T2 BX20S2T12 1180 410 11023 BX24S2T2 BX24S2T12 1180 410 110BX8S2T12250A ISOLATOR INCOMER c/w SPDNO. of O/G TP WAYS CAT. NO. TYPE 2 SPDCAT. NO. TYPE 1+2 SPDH W D7 BX8S250T2 BX8S250T12 950 500 17011 BX12S250T2 BX12S250T12 950 500 17015 BX16S250T2 BX16S250T12 1300 500 17019 BX20S250T2 BX20S250T12 1300 500 17023 BX24S250T2 BX24S250T12 1300 500 170BX12S250T2For surge protection Info, SPD selection chart, loose surge arrestors and enclosed surge arrestors please go to pages 57, 58 & 59SURGE PROTECTION DEVICES
31 | PROTEUS INDUSTRIALPROTEUS INDUSTRIAL• Available in 4, 6, 8, 12, 16, 20 to 24 triple pole outgoing ways.• Wide selection of factory fitted incoming devices to choose from to meet the demands of modern BX12S2125A ISOLATOR INCOMER DISTRIBUTION BOARDS200A ISOLATOR INCOMER DISTRIBUTION BOARDSBX8S125installations.• Accepts MCBs from 2A to 63A and RCBOs from 6A to 45A (17.5 mm wide module).• Dual Earth and Neutral terminal bars.• Manufactured to BSEN 61439 parts 1 & 3.• Removable gland plates, top and bottom.BX 3-PHASE DISTRIBUTION BOARDSBX8S250250A ISOLATOR INCOMER DISTRIBUTION BOARDSMeasurements:Millimetres (mm) unless stated otherwiseOutgoing Switchgear:Supplied separatelyDoor Options:Supplied with a solid door as standard and can be ordered with a clear door fitted be adding /CD to the part code. (For example: BX6S125/CD)FEATURES:BX 3-Phase Distribution BoardsINCOMER (FACTORY FITTED)NO. of O/G TP WAYS CAT. NO. (SOLID DOOR)H W D125A TP Isolator 4 BX4S125 (4P) 390 410 110125A TP Isolator 6 BX6S125 (4P) 442 410 110125A TP Isolator 8 BX8S125 (4P) 495 410 110125A TP Isolator 12 BX12S125 (4P) 600 410 110125A TP Isolator 16 BX16S125 (4P) 810 410 110125A TP Isolator 20 BX20S125 (4P) 1000 410 110125A TP Isolator 24 BX24S125 (4P) 1180 410 110INCOMER (FACTORY FITTED)NO. of O/G TP WAYS CAT. NO. (SOLID DOOR)H W D200A TP Isolator 4 BX4S2 600 410 110200A TP Isolator 6 BX6S2 600 410 110200A TP Isolator 8 BX8S2 700 410 110200A TP Isolator 12 BX12S2 810 410 110200A TP Isolator 16 BX16S2 1000 410 110200A TP Isolator 20 BX20S2 1180 410 110200A TP Isolator 24 BX24S2 1180 410 110INCOMER (FACTORY FITTED)NO. of O/G TP WAYS CAT. NO. (SOLID DOOR)H W D250A TP Isolator 8 BX8S250 950 500 170250A TP Isolator 12 BX12S250 950 500 170250A TP Isolator 16 BX16S250 1300 500 170250A TP Isolator 20 BX20S250 1300 500 170250A TP Isolator 24 BX24S250 1300 500 170(4P) - Add suffix ‘4P’ for 4 pole incomer fitted boards e.g. BX4S1254P
32PROTEUS INDUSTRIAL | BX 3-PHASE DISTRIBUTION BOARDSBX 3-Phase Distribution BoardsBX6P30BX6Q3063A TYPE A 4 POLE 30 mA RCD INCOMER DISTRIBUTION BOARDS80A TYPE A 4 POLE 30 mA RCD INCOMER DISTRIBUTION BOARDSBX MULTI PURPOSE UNITSBXM14INCOMER (FACTORY FITTED)NO. of O/G TP WAYS CAT. NO. (SOLID DOOR)H W D63A 4P 30 mA RCD 4 BX4P30 390 410 11063A 4P 30 mA RCD 6 BX6P30 442 410 11063A 4P 30 mA RCD 8 BX8P30 495 410 11063A 4P 30 mA RCD 12 BX12P30 600 410 11063A 4P 30 mA RCD 16 BX16P30 810 410 11063A 4P 30 mA RCD 20 BX20P30 1000 410 11063A 4P 30 mA RCD 24 BX24P30 1180 410 110INCOMER (FACTORY FITTED)NO. of O/G TP WAYS CAT. NO. (SOLID DOOR)H W D80A 4P 30 mA RCD 4 BX4Q30 390 410 11080A 4P 30 mA RCD 6 BX6Q30 442 410 11080A 4P 30 mA RCD 8 BX8Q30 495 410 11080A 4P 30 mA RCD 12 BX12Q30 600 410 11080A 4P 30 mA RCD 16 BX16Q30 810 410 11080A 4P 30 mA RCD 20 BX20Q30 1000 410 11080A 4P 30 mA RCD 24 BX24Q30 1180 410 110DESCRIPTION CAT. NO. (SOLID DOOR)H W D14 Modules BXM14 265 410 11028 Modules (2x 14 mod banks)BXM28 495 410 110DID YOU KNOW?BX boards are supplied with a solid door as standard and can be ordered with a clear door fitted by adding /CD to the part code (For example: BX6S2/CD).Measurements:Millimetres (mm) unless stated otherwiseOutgoing Switchgear:Supplied separately
33 | PROTEUS INDUSTRIALPROTEUS INDUSTRIAL100A TYPE A 4 POLE 100 mA RCD INCOMER DISTRIBUTION BOARDSBX6R100100A TYPE A 4 POLE 300 mA RCD INCOMER DISTRIBUTION BOARDSBX6R300BX4R30100A TYPE A 4 POLE 30 mA RCD INCOMER DISTRIBUTION BOARDSBX ACCESSORIESBXSB2100A 100 mA boards available with Type S RCD on request.100A 300 mA boards available with Type S RCD on request.INCOMER (FACTORY FITTED)NO. of O/G TP WAYSCAT. NO. (SOLID DOOR)H W D100A 4P 30 mA RCD 4 BX4R30 390 410 110100A 4P 30 mA RCD 6 BX6R30 442 410 110100A 4P 30 mA RCD 8 BX8R30 495 410 110100A 4P 30 mA RCD 12 BX12R30 600 410 110100A 4P 30 mA RCD 16 BX16R30 810 410 110100A 4P 30 mA RCD 20 BX20R30 1000 410 110100A 4P 30 mA RCD 24 BX24R30 1180 410 110INCOMER (FACTORY FITTED)NO. of O/G TP WAYSCAT. NO. (SOLID DOOR)H W D100A 4P 100 mA RCD 4 BX4R100 390 410 110100A 4P 100 mA RCD 6 BX6R100 442 410 110100A 4P 100 mA RCD 8 BX8R100 495 410 110100A 4P 100 mA RCD 12 BX12R100 600 410 110100A 4P 100 mA RCD 16 BX16R100 810 410 110100A 4P 100 mA RCD 20 BX20R100 1000 410 110100A 4P 100 mA RCD 24 BX24R100 1180 410 110INCOMER (FACTORY FITTED)NO. of O/G TP WAYSCAT. NO. (SOLID DOOR)H W D100A 4P 300 mA RCD 4 BX4R300 390 410 110100A 4P 300 mA RCD 6 BX6R300 442 410 110100A 4P 300 mA RCD 8 BX8R300 495 410 110100A 4P 300 mA RCD 12 BX12R300 600 410 110100A 4P 300 mA RCD 16 BX16R300 810 410 110100A 4P 300 mA RCD 20 BX20R300 1000 410 110100A 4P 300 mA RCD 24 BX24R300 1180 410 110DESCRIPTION CAT. NO. H W DSpreader box BXSB1 265 410 110Spreader box BXSB2 495 410 110100/125A Single phase conv kit BXSCK1 - - -200A Single phase conv kit BXSCK2 - - -Key lock for door XLKL - - -BX 3-Phase Distribution BoardsMeasurements:Millimetres (mm) unless stated otherwiseOutgoing Switchgear:Supplied separatelyDoor Options:Supplied with a solid door as standard and can be ordered with a clear door fitted be adding /CD to the part code. (For example: BX6R30/CD)BX 3-PHASE DISTRIBUTION BOARDS
34PROTEUS INDUSTRIAL | 3-PHASE ABX BOARD - HORIZONTALABX2S1• Busbars are 80A max with 100A intermittent rating and are one piece construction.• Cleanline overall hinged door (key operated lockable door optional).• Accepts RCBOs and MCBs, 17.5 mm wide module.• Isolators can be locked in ON or OFF position (using DLPX1 locking device).• Robust IP3X steel construction.• ABX Manufactured to BSEN 61439 parts 1 & 3.3-PHASE ABX BOARD - VERTICALABX4S1VABX 3 PHASE DISTRIBUTION BOARDSHORIZONTAL ABX TYPE A RCD BOARDSABX2R30ABX4R300VVERTICAL ABX TYPE A RCD BOARDSMeasurements:Millimetres (mm) unless stated otherwiseOutgoing Switchgear:Supplied separatelyDoor Options:Supplied with a solid door as standard and can be ordered with a clear door fitted be adding /CD to the part code. (For example: ABX6S1/CD)FEATURES:ABX 3-Phase Distribution BoardsINCOMER FACTORY FITTEDNO. of O/G TP WAYSCAT. NO. (SOLID DOOR)H W D100A 4P Isolator 2 ABX2S1 269 326 110100A 4P Isolator 4 ABX4S1 269 436 110100A 4P Isolator 6 ABX6S1 269 562 110100A 4P Isolator 8 ABX8S1 269 673 110100A 4P Isolator 12 ABX12S1 269 900 110INCOMER FACTORY FITTEDNO. of O/G TP WAYSCAT. NO. (SOLID DOOR)H W D100A 4P Isolator 2 ABX2S1V 326 269 110100A 4P Isolator 4 ABX4S1V 436 269 110100A 4P Isolator 6 ABX6S1V 562 269 110100A 4P Isolator 8 ABX8S1V 673 269 110100A 4P Isolator 12 ABX12S1V 900 269 110NO. of O/G TP WAYSCAT. NO.100A 30 mA RCD INCOMERCAT. NO.100A 100 mA RCD INCOMERCAT. NO.100A 300 mA RCD INCOMERH W D2 ABX2R30 ABX2R100 ABX2R300 269 326 1104 ABX4R30 ABX4R100 ABX4R300 269 436 1106 ABX6R30 ABX6R100 ABX6R300 269 562 1108 ABX8R30 ABX8R100 ABX8R300 269 673 11012 ABX12R30 ABX12R100 ABX12R300 269 900 110NO. of O/G TP WAYSCAT. NO.100A 30 mA RCD INCOMERCAT. NO.100A 100 mA RCD INCOMERCAT. NO.100A 300 mA RCD INCOMERH W D2 ABX2R30V ABX2R100V ABX2R300V 326 269 1104 ABX4R30V ABX4R100V ABX4R300V 436 269 1106 ABX6R30V ABX6R100V ABX6R300V 562 269 1108 ABX8R30V ABX8R100V ABX8R300V 673 269 11012 ABX12R30V ABX12R100V ABX12R300V 900 269 110
35 | PROTEUS INDUSTRIALPROTEUS INDUSTRIALCase StudyCASE STUDY:Proteus Switchgear PRO2000 LV switchboard was designed to tap off from an 11kV ring to supply the vast majority of the Thomas Land’s electrical needs.DRAYTON MANOR THEME PARK - THOMAS LANDPRO2000 LV SWITCHBOARDSThe timescale for the project was tight from the onset and as quoted by the contractor only Proteus Switchgear offered to meet the challenge. The goods were specified, quoted, designed and supplied within 8 weeks. Keeping the progress of the project on schedule and supporting the contractor along the way with respect to technical support and advice were key to customer satisfaction.Proteus Switchgear were also noted for their excellent co-operation and team work when it came to accommodating a significant mid-project modification to the switchboard involving the upgrading of an outgoing switch fuse from 100A to 250A. With the assistance of Proteus staff the work involved in changeover was completed in less than 1 hourThe contractor claims the high profile of the installation and overall successful completion and handover of the project has also increased the profile of his company and led to further job opportunities for his team with work on this scale.BESPOKE SOLUTIONIN-HOUSE DESIGN FACILITIESTECHNICAL SUPPORT FROM MANUFACTURER
36PROTEUS INDUSTRIAL | IP65 POWER DISTRIBUTION BOARDS125A TP ISOLATOR - STEEL ENCLOSURE200A TP ISOLATOR - STEEL ENCLOSURE125A TP ISOLATOR - GRP ENCLOSURE 200A TP ISOLATOR - GRP ENCLOSURE• All boards will accept RCBOs and MCBs 17.5 mm wide modules.• Isolators can be locked in ON or OFF position (using DL1 locking device).PDU4SPDU6S2SPDU4SSPDU4S2Measurements:Millimetres (mm) unless stated otherwiseRCD Incomer:Factory fitted 100A 4 pole RCD incomer options available on requestKey Lock Options:GRP boards part code - GRPKLSteel boards part code - STLKLFEATURES:IP65 Power Distribution BoardsINCOMER FACTORY FITTEDNO. of O/G TP WAYSCAT. NO. (SOLID DOOR)H W D125A TP isolator 4PDU4SS500 400 200125A TP isolator 6PDU6SS600 400 200125A TP isolator 8PDU8SS600 400 200125A TP isolator 12PDU12SS800 400 200125A TP isolator 16PDU16SS800 400 200INCOMER FACTORY FITTEDNO. of O/G TP WAYSCAT. NO. (SOLID DOOR)H W D200A TP isolator 4PDU4S2S600 400 200200A TP isolator 6PDU6S2S600 400 200200A TP isolator 8PDU8S2S800 400 200200A TP isolator 12PDU12S2S1100 400 200200A TP isolator 16PDU16S2S1300 400 200INCOMER FACTORY FITTEDNO. of O/G TP WAYSCAT. NO. (SOLID DOOR)H W D125A TP isolator 4PDU4S500 400 200125A TP isolator 6PDU6S600 500 250125A TP isolator 8PDU8S600 500 250125A TP isolator 12PDU12S800 600 300125A TP isolator 16PDU16S800 600 300INCOMER FACTORY FITTEDNO. of O/G TP WAYSCAT. NO. (SOLID DOOR)H W D200A TP isolator 4PDU4S2600 500 250200A TP isolator 6PDU6S2600 500 250200A TP isolator 8PDU8S2800 600 300• Manufactured to BSEN 61439 parts 1 & 3.
37 | PROTEUS INDUSTRIALPROTEUS INDUSTRIALMeasurements:Millimetres (mm) unless stated otherwiseAdditional ratings available upon request. Manufactured to BSEN 60947.Fuse Gear & IsolatorsWFS100/IP65 WSF63/IP65SSIP65 SWITCH DISCONNECTOR FUSESHWD1D2AC23 RATED SWITCH DISCONNECTOR FUSESIP65 STEEL ENCLOSUREAC23 RATED SWITCH DISCONNECTOR FUSESIP65 GRP ENCLOSURESWITCH DISCONNECTOR FUSES IP65 STEEL ENCLOSURESWITCH DISCONNECTOR FUSES IP65 GRP ENCLOSURECURRENT RATING A AC21 / AC23NO. of POLES CAT. NO. H W D1 D263 3P + N WFS63/IP65SS 500 400 200 70100 3P + N WFS100/IP65SS 500 400 200 70125 3P + N WFS125/IP65SS 600 400 200 70160 3P + N WFS160/IP65SS 600 400 200 70200 3P + N WFS200/IP65SS 700 500 300 70CURRENT RATING A AC21 / AC23NO. of POLES CAT. NO. H W D1 D263 3P + N WFS63/IP65 500 400 200 70100 3P + N WFS100/IP65 500 400 200 70125 3P + N WFS125/IP65 600 500 250 70160 3P + N WFS160/IP65 600 500 250 70200 3P + N WFS200/IP65 800 600 300 70CURRENT RATING A AC21 / AC23NO. of POLES CAT. NO. H W D1 D220/11 3P + N WSF20/IP65SS 400 300 200 4032/18 3P + N WSF32/IP65SS 400 300 200 4063/35 3P + N WSF63/IP65SS 500 400 200 40100/70 3P + N WSF100/IP65SS 500 400 200 40CURRENT RATING A AC21 / AC23NO. of POLES CAT. NO. H W D1 D220/11 3P + N WSF20/IP65 400 300 200 4032/18 3P + N WSF32/IP65 400 300 200 4063/35 3P + N WSF63/IP65 500 400 200 40100/70 3P + N WSF100/IP65 500 400 200 40• AC21 - Switching of resistive loads, including moderate overloadsFEATURES:• AC23 - Switching of motor loads or other high inductive loadsFor 3 & 4 pole IP67 rotary isolators please go to pages 122 & 123IP67 ROTARY ISOLATORSIP67LOCK OFF20ATO100APOSITIONPROTECTION
38PROTEUS INDUSTRIAL | U SWITCHGEAR RANGEU200FSHWD1D2• Switch mechanism rated at 65kA when fitted with appropriate BS88 fuses.• Heavy duty interlocking handle.• Fully rated BS88 fuses fitted.• 4 pole configuration available on request.• Built-in cable box suitable for most applications.* - when using 95 mm2 cable it is recommended that the UCB1 is fitted.** - when using 185 mm2 cable it is recommended that the UCB2 is fitted.# - when using 240 mm2 cable it is recommended that the UCB4 is fitted.*** - Floor standing unit.FEATURES:AC23 RATED SWITCH DISCONNECTOR FUSESCURRENT RATING A-AC23CSA MAX mm2BOLT SIZE (METRIC)POWER RATING AT 400 V (kW)PROTEUS BS88 PT.2 FUSE FITTEDCAT. NO. H W D1 D263 95*M833 PBD U63FS 500 350 185 70100 95*M855 PCD U100FS 500 350 185 70125 95*M859 PDD U125FS 500 350 185 70160 95*M875 PDD U160FS 500 350 185 70200 150/185**M10110 PDD U200FS 700 400 255 70250 150/185**M10132 PED U250FS 700 400 255 70315 185**M10185 PED U315FS 700 400 255 70400 185/240#M10220 PED U400FS 900 400 330 70500 -M12275 PFF U500FS 1300 500 300 70630 -M12300 PFF 630FS 1300 500 300 55800 -M12450 PGF 800FS*** 1625 654 500 55Measurements:Millimetres (mm) unless stated otherwiseFuse Gear & Isolators63A - 800A Triple Pole and Neutral Fuse Switch complete with Built In Spreader Boxes and FusesSTEELENCLOSUREOFFFORSECURITY• Manufactured to BSEN 60947 parts 1 & 3.• AC21 - Switching of resistive loads, including moderate overloads• AC23 - Switching of motor loads or other high inductive loads• Removable endplates For 3 & 4 pole IP67 rotary isolators please go to pages 122 & 123IP67 ROTARY ISOLATORSIP67LOCK OFF20ATO100APOSITIONPROTECTION
39 | PROTEUS INDUSTRIALPROTEUS INDUSTRIALU SWITCHGEAR RANGEHWD1D2* - when using 95 mm2 cable it is recommended that the UCB1 is fitted.** - when using 185 mm2 cable it is recommended that the UCB2 is fitted.# - when using 240 mm2 cable it is recommended that the UCB4 is fitted.AC23 RATED SWITCH DISCONNECTORSACCESSORIESU200SUCB2Measurements:Millimetres (mm) unless stated otherwiseFuse Gear & IsolatorsCURRENT RATING A-AC23CSA MAX mm2BOLT SIZE (METRIC)POWER RATING AT 400 V (kW)CAT. NO. H W D1 D263 95*M833 U63S 500 350 185 70100 95*M855 U100S 500 350 185 70125 95*M859 U125S 500 350 185 70160 95*M875 U160S 500 350 185 70200 150/185**M10110 U200S 700 400 255 70250 150/185**M10132 U250S 700 400 255 70315 185**M10185 U315S 700 400 255 70400 185/240#M10220 U400S 900 400 330 70 500 -M12275 U500S 1300 500 300 70630 -M12300 U630S 1300 500 300 7063A - 630A Triple Pole and Neutral Metalclad Switch Disconnector• AC21 - Switching of resistive loads, including moderate overloads• AC23 - Switching of motor loads or other high inductive loadsFEATURES:DESCRIPTION CAT. NO. H W DCable spreader box to suit up to U160FS/U160SUCB1 200 350 185Cable spreader box to suit U200FS/U200S upto U315FS/U315SUCB2 200 400 255Cable spreader box to suit U400FS/U400SUCB4 200 400 330Fuse barrier for U250FS/S - U400FS/SUFB200 - - -Fuse barrier for U063FS/S - U160FS/SUFB63 - - -Handle for UFS/SUFH - - -Shaft for UFS/SUFS - - -STEELENCLOSUREOFFFORSECURITY
40PROTEUS INDUSTRIAL | EURO SWITCHGEAR RANGEKey features - as above plus, Fully rated fuses fitted. Cable Termination Type - Tunnel. TIS and TCP are ‘Bolt in’ fuses to BS88 pt2. Accessory - MN10 is a screw fixed add-on switched neutral pole for 63/100A unitsSWITCH DISCONNECTOR FUSESHWD1D2EF20TNMeasurements:Millimetres (mm) unless stated otherwiseFuse Gear & Isolators• Fully insulated high visibility rotary operating handle.• Padlockable in off position for security.• Finger protected cable terminations.FEATURES:• Epoxy powder coat finish.• Robust, heavy duty steel enclosure.• Folded steel construction for extra rigidity.• Flush fitting door.• Door removable for ease of installation.• Manufactured to BSEN 60947 parts 1 & 3.CURRENT RATING A-AC21A/AC22ANO. of POLESCURRENT RATING A-AC23APOWER AT 400 V (kW) AC23AMAX. STRANDED CABLE CSA mm2PROTEUS FUSE TO BS88 PT.2&6 SPARE FUSE UNITCAT. NO. H W D1 D220 3 P+N 11 5.5 16 PNSD/TDH2 Part [6] EF20TN 283 235 125 3520 1 P+N - - 16 PNSD/TDH2 Part [6] EF20S 283 235 125 3520 2 P+N - - 16 PNSD/TDH2 Part [6] EF20D 283 235 125 3532 3 P+N 18 9 16 PNSD/TDH3 Part [6] EF32TN 283 235 125 3532 1 P+N - - 16 PNSD/TDH3 Part [6] EF32S 283 235 125 3532 2 P+N - - 16 PNSD/TDH3 Part [6] EF32D 283 235 125 3563 3 P+N 63 35 35 TIS/TDH6 Part [2] EF63TN 420 300 145 4563 1 P+N - - 35 TIS/TDH6 Part [2] EF63S 420 300 145 4563 2 P+N - - 35 TIS/TDH6 Part [2] EF63D 420 300 145 45100 3 P+N 100 50 70 (in) 35 (out) TCP/TDH10 Part [2] EF100TN 420 350 145 45100 1 P+N - - 35 TCP/TDH10 Part [2] EF100S 420 350 145 45100 2 P+N - - 35 TCP/TDH10 Part [2] EF100D 420 350 145 4520A - 100A Triple Pole and Neutral Switch Fuse c/w FusesSTEELENCLOSUREOFFFORSECURITY
41 | PROTEUS INDUSTRIALPROTEUS INDUSTRIALMeasurements:Millimetres (mm) unless stated otherwiseSWITCH DISCONNECTORSE20TNCURRENT RATING A-AC21A/AC22ACURRENT RATING A-AC23APOWER AT 400 V (kW) AC23AMAX. STRANDED CABLE CSA mm2CABLE TERMINATION TYPECAT. NO. H W D1 D220 11 6.5 16 Tunnel E20TN 195 235 125 3532 28 15 16 Tunnel E32TN 195 235 125 3563 63 37 35 Tunnel E63TN 383 235 125 35100 100 50 70 Tunnel E100TN 383 235 125 35160 80 75 70 Tunnel E160TN 420 300 145 45200 125 75 70 Tunnel E200TN 420 300 145 4520A - 200A Triple Pole and Neutral Metalclad Switch DisconnectorSTEELENCLOSUREOFFFORSECURITYHWD1D2ADD ON NEUTRALEN100DESCRIPTION CURRENT RATING CAT. NO.20 / 32 A Add on neutral 20 A / 32 A EN20/3263 A Add on neutral 63 A EN63100 A Add on neutral 100 A EN100Suitable for Switch Disconnectors & Switch Disconnector FusesFuse Gear & IsolatorsEURO SWITCHGEAR RANGE
42PROTEUS INDUSTRIAL | HWD1D2CO204CHANGEOVER SWITCHESGRP ENCLOSURES TO IP65 - 20 & 32A• Manufactured to BSEN 60947 Parts 1 & 3.• Robust enclosure powder coated to RAL7035.• Removable end plates.FEATURES:Measurements:Millimetres (mm) unless stated otherwiseChangeover SwitchesCURRENT RATING A AC21NO. of POLESCABLE SIZE mm2CAT. NO. H W D1 D2100 4 50 (M8) TCO1004 500 440 175 50125 4 50 (M8) TCO1254 500 440 175 50160 4 95 (M8) TCO1604 700 565 190 50200 4 95 (M8) TCO2004 700 565 190 50250 4 240 (M10) TCO2504 800 720 220 50315 4 240 (M10) TCO3154 800 720 220 50400 4 240 (M10) TCO4004 800 720 220 50630 4 300 (M12) TCO6304 1300 1300 300 70800 4 300 (M12) TCO8004 1300 1300 300 70STEEL ENCLOSURES TO IP3X - 100 - 800ACURRENT RATING A AC21NO. of POLESCABLE SIZE mm2CAT. NO. H W D1 D220 2 2.5 CO/202 126 101 96 2520 4 2.5 CO/204 126 101 96 2532 2 6 CO/322 176 116 111 2532 4 6 CO/324 176 116 111 25GRP ENCLOSURES TO IP65 - 63 & 100ACURRENT RATING A AC21NO. of POLESCABLE SIZE mm2CAT. NO. H W D1 D263 2 35 CO/632 240 160 169 2563 4 35 CO/634 246 160 169 25100 2 35 CO/1002 240 160 169 25100 4 35 CO/1004 240 160 169 25CO633TCO1254
43 | PROTEUS INDUSTRIALPROTEUS INDUSTRIALCase StudyCASE STUDY:In March 2014, Innovia Films announced that they had signed a contract with the Bank of England for Innovia Security to supply Guardian® polymer substrate for the next generation of UK sterling bank notes.INNOVIA FILMSPRO2000 SWITCHBOARDSProteus Industrial has supplied Innovia Films since 2010 in an on-going programme of replacing much of their old switchgear with the latest, and in some cases totally bespoke, control equipment. By working closely with the Electrical Engineering Manager and the electrical team at Innovia, a new order has just been placed by City Electrical Factors (CEF) Carlisle branch, for two purpose built PRO2000 switchboards to distribute 400V power throughout the state of the art Innovia Security facility as part of the programme.Designed and built in the Proteus factory in Telford, the customer was able to see the switch board being built to their unique specification. “As a British manufacturer ourselves it is great to be able to talk and actually see our own panel being built” said the customer, “I cannot think of another company left in the UK that could offer this service”.BESPOKE SOLUTIONIN-HOUSE DESIGN FACILITIESTECHNICAL SUPPORT FROM MANUFACTURER
44PROTEUS INDUSTRIAL | HWD100A BUSBAR CHAMBERSBUSBAR CHAMBERS200A BUSBAR CHAMBERS100BC2 200BC3300BC3400BC4600BC6• Manufactured to BSEN 61439-1 & 2.• 4 pole configuration.• 6 ratings from 100A to 800A.FEATURES:Measurements:Millimetres (mm) unless stated otherwiseHigher Ratings:Available on requestBusbar Chambers• 36kA Icc.• Fully rated neutral.• Twin bar design from 100A up to 800A.• Set of 4 clamps supplied with each chamber.CURRENT RATING ANO. of POLES CAT. NO. H W D100 4 100BC2 400 610 190100 4 100BC3 400 915 190100 4 100BC4 400 1220 190100 4 100BC6 400 1830 190CURRENT RATING ANO. of POLES CAT. NO. H W D200 4 200BC2 400 610 190200 4 200BC3 400 915 190200 4 200BC4 400 1220 190200 4 200BC6 400 1830 190315A BUSBAR CHAMBERS 400A BUSBAR CHAMBERSCURRENT RATING ANO. of POLES CAT. NO. H W D315 4 300BC2 400 610 190315 4 300BC3 400 915 190315 4 300BC4 400 1220 190315 4 300BC6 400 1830 190CURRENT RATING ANO. of POLES CAT. NO. H W D400 4 400BC2 400 610 190400 4 400BC3 400 915 190400 4 400BC4 400 1220 190400 4 400BC6 400 1830 190630A BUSBAR CHAMBERS800A BUSBAR CHAMBERSCURRENT RATING ANO. of POLES CAT. NO. H W D630 4 600BC2 400 610 190630 4 600BC3 400 915 190630 4 600BC4 400 1220 190630 4 600BC6 400 1830 190CURRENT RATING ANO. of POLES CAT. NO. H W D800 4 800BC3 400 915 190800 4 800BC4 400 1220 190800 4 800BC6 400 1830 190800BC6
45 | PROTEUS INDUSTRIALPROTEUS INDUSTRIALCONNECTION BOLTSM6 BOLT SIZEBLC6/23M8 BOLT SIZEM10 BOLT SIZECLAMPBLC10/48BLC8/23BCC240/48BOLTS TO SUIT BUSBARBOLT SIZE (METRIC)MAX. CABLE SIZE mm2CAT. NO.100 - 200A Rated M6 70 BLC6/23315 - 800A Rated M6 70 BLC6/48BOLTS TO SUIT BUSBARBOLT SIZE (METRIC)MAX. CABLE SIZE mm2CAT. NO.100 - 200A Rated M8 150 BLC8/23315 - 800A Rated M8 150 BLC8/48BOLTS TO SUIT BUSBARBOLT SIZE (METRIC)MAX. CABLE SIZE mm2CAT. NO.315 - 800A Rated M10 150 BLC10/48BOLTS TO SUIT BUSBARBOLT SIZE (METRIC)MAX. CABLE SIZE mm2CAT. NO.100 - 200A Rated Clamp 185 BCC185/23315 - 800A Rated Clamp 185 BCC185/48315 - 800A Rated Bolt 240 BCC240/48Measurements:Millimetres (mm) unless stated otherwiseBusbar Chambers
46PROTEUS INDUSTRIAL | ABS ENCLOSURESIP65E504024MULTIPURPOSE IP65 ENCLOSURESHWDMULTIPURPOSE IP65 ENCLOSURESIP65E604020/CD• Designed to meet protection and combustible standards IP65 and IK08.• Available in 6 sizes.• Supplied in grey (RAL 7035) with solid door and FEATURES:Measurements:Millimetres (mm) unless stated otherwiseABS Enclosuresbase unit (internal mounting plate).• Wall thickness on the range is 3 – 3.5 mm.• Made from UL approved ABS-HB flame retardant plastic.• Complying with BS EN 60529, BS EN 62208, • CEI23-48 & CEI23-49DESCRIPTION CAT. NO. H W DIP65 enclosure IP65E302013 300 200 130IP65 enclosure IP65E352515 350 250 150IP65 enclosure IP65E403022 400 300 220IP65 enclosure IP65E504024 500 400 240IP65 enclosure IP65E604020 600 400 200IP65 enclosure IP65E705025 700 500 250DESCRIPTION CAT. NO. H W DIP65 enclosure IP65E302013/CD 300 200 130IP65 enclosure IP65E352515/CD 350 250 150IP65 enclosure IP65E403022/CD 400 300 220IP65 enclosure IP65E504024/CD 500 400 240IP65 enclosure IP65E604020/CD 600 400 200IP65 enclosure IP65E705025/CD 700 500 250HWDIP65 ABS Enclosure with Back Plate Fitted and A Solid Grey DoorIP65 ABS Enclosure with Back Plate Fitted and A Translucent Door
47 | PROTEUS INDUSTRIALPROTEUS INDUSTRIALCONTACTORS & EMERGENCY STOPSEM/STOP3 POLE CONTACTORSIP65 EMERGENCY STOP PUSH BUTTONSIP65 EMERGENCY STOP PUSH BUTTONSENCLOSED HEATING AND LIGHTING CONTACTORSConform to BSEN 60947-4.MEMIHLC100PC063230VMeasurements:Millimetres (mm) unless stated otherwiseContactors & Emergency Stops• Compliant with BSEN 60947-4, CSA approved and UL Listing.• Terminal marking to EN50005.• Climate rating tested to DIN50 016 and IEC68.FEATURES:• Standard 230V a.c. coil voltage.• Generous cabling connections.• Clear identification of contact position and function.• Full range of auxiliary components.POWER RATING (KW) 400 VAC1 RATING A AT 400 VAC3 RATING A AT 400 V3 POLE CAT. NO.4 20 9 PC020230V5.5 25 12 PC025230V11 32 22 PC032230V22 63 50 PC063230V45 100 85 PC100230V75 200 150 PC200230VDESCRIPTION CAT. NO. H W DEmergency Stop Push Button - Twist ReleaseEM/STOP* 72 70 63N/C Contact Block To Suit EM/STOPEMCB1NC - - -N/O Contact Block To Suit EM/STOPEMCB1NO - - -* - Contact configuration - 1NCDESCRIPTION CAT. NO. H W DNeon Ind./Twist Release MEMI* 72 80 50Key release MEMK* 72 80 50Twist release MEMT* 72 80 50Twist release w/ safety snap MEMSS* 72 80 50N/C Contact Block To Suit MEM.... PCB1NC - - -N/O Contact Block To Suit MEM... PCB1NO - - -* - Contact configuration - 1NC/1NOAC1 RATING AAC3 RATING AAUX. CONTACTS FITTEDCAT. NO. H W D25 12 1 NO HLC25 200 200 17032 22 1 NO HLC32 200 200 17063 50 1 NO/1 NC HLC63 300 300 170100 85 1 NO/1 NC HLC100 300 300 170200 150 1 NO/1 NC HLC200 700 400 300
48PROTEUS INDUSTRIAL | EARTH BARSPEB8L WHPEBTL12/800• Earth Bars are manufactured from HDHC copper supported on glass reinforced polyester insulators. The CSA of the bar is nominally 150 mm² (25 mm x 6 mm / 1” x 1/4”) with a current rating of 400A FEATURES:Measurements:Millimetres (mm) unless stated otherwiseBolt Sizes:Main bolts M12Outgoing bolts M8Higher Rating:Available on request up to 2000AEarth Barsand 300 mm2 (30 mm x 10 mm) for 800A.• The insulators are mounted on a steel ‘top hat’ section for fixing to the wall.• Mounted on insulated supports (may be used as neutral bars).NO. of O/G CONNECTIONSINTEGRAL TEST LINKCAT. NO. L W H6 No PEB6/800 315 65 688 No PEB8/800 385 65 6812 No PEB12/800 525 65 686 Yes PEBTL6/800 470 65 688 Yes PEBTL8/800 540 65 6812 Yes PEBTL12/800 680 65 6830 kA Is, 63 kA PEAK. 800A EARTH BARSNO. of O/G CONNECTIONSINTEGRAL TEST LINKCAT. NO. L W H4 No PEB4 245 65 686 No PEB6 315 65 688 No PEB8 385 65 6812 No PEB12 525 65 686 Yes PEBTL6 470 65 688 Yes PEBTL8 540 65 6812 Yes PEBTL12 680 65 6815 kA Is, 30 kA PEAK. 400A EARTH BARSL WH
49 | PROTEUS INDUSTRIALPROTEUS INDUSTRIALMINIATURE CIRCUIT BREAKERSServicesProteus offer a large range of custom designed, bespoke LV switchboards, panelboards, distribution boards and consumer units. Ensure your customer’s exact requirements are met with a completely bespoke solution.Designed to Your SpecificationOn-Site SurveyTesting & ComplianceBe involvedOur team are happy to visit your site to establish your project requirementsProteus utilise the latest drawing software and provide panel layout drawings at both quotation and construction stagesAll products tested to relevant British & European Standards and the 18th Edition Wiring RegulationsYou’re welcome to visit the factory to see your board being built and discuss build requirementsBESPOKE POWER DISTRIBUTION CONFIGURATIONSFROM PROTEUS
50PROTEUS | 616BSINGLE POLE MCBs - B CURVE21016/3DOUBLE POLE MCBs - C CURVECURRENT RATING (A) 6 kA 10 kA 15 kA1 601B - -2 602B 1002/2 1502/24 604B 1004/2 1504/26 606B 1006/2 1506/210 610B 1010/2 1510/216 616B 1016/2 1516/220 620B 1020/2 1520/225 625B - 1525/232 632B 1032/2 1532/240 640B 1040/2 1540/245 645B - -50 650B 1050/2 1550/263 663B 1063/2 1563/2CURRENT RATING (A) 10 kA DP6 21006/310 21010/316 21016/320 21020/325 21025/332 21032/340 21040/350 21050/363 21063/3MINIATURE CIRCUIT BREAKERSCircuit Protection DevicesCURRENT RATING (A) 6 kA 10 kA 15 kA1 - - -2 - 1002/3 1502/34 - 1004/3 1504/36 606C 1006/3 1506/310 610C 1010/3 1510/316 616C 1016/3 1516/320 620C 1020/3 1520/325 625C 1025/3 1525/332 632C 1032/3 1532/340 640C 1040/3 1540/345 - - -50 650C 1050/3 1550/363 663C 1063/3 1563/3CURRENT RATING (A) 10 kA 15 kA1 - -2 - 1502/44 - 1504/46 1006/4 1506/410 1010/4 1510/416 1016/4 1516/420 1020/4 1520/425 - 1525/432 1032/4 1532/440 1040/4 1540/445 - -50 1050/4 1550/463 1063/4 1563/41025/3SINGLE POLE MCBs - C CURVE1532/4SINGLE POLE MCBs - D CURVEMeasurements:Millimetres (mm) unless stated otherwiseUse the colour code to identify the supplying Proteus Division:Blue box:Proteus Consumer No box:Proteus Industrial
51 | PROTEUSPROTEUSPROTEUS INDUSTRIALMINIATURE CIRCUIT BREAKERS4 Pole MCBs cannot be fitted in MCB boards.31032/3Circuit Protection DevicesCURRENT RATING (A) 10 kA6 41006/310 41010/316 41016/320 41020/332 41032/340 41040/350 41050/363 41063/3FOUR POLE MCBs - C CURVE41032/331032/2TRIPLE POLE MCBs - B CURVECURRENT RATING (A) 10 kA TP 15 kA TP2 - 31502/24 - 31504/26 31006/2 31506/210 31010/2 31510/216 31016/2 31516/220 31020/2 31520/225 - 31525/232 31032/2 31532/240 31040/2 31540/250 31050/2 31550/263 31063/2 31563/2CURRENT RATING (A) 6 kA 10 kA 15 kA2 - 31002/3 31502/34 - 31004/3 31504/36 3606C 31006/3 31506/310 3610C 31010/3 31510/316 3616C 31016/3 31516/320 3620C 31020/3 31520/325 3625C 31025/3 31525/332 3632C 31032/3 31532/340 3640C 31040/3 31540/350 3650C 31050/3 31550/363 3663C 31063/3 31563/3TRIPLE POLE MCBs - C CURVE31516/4TRIPLE POLE MCBs - D CURVECURRENT RATING (A) 10 kA TP 15 kA TP2 31502/44 31504/46 31006/4 31506/410 31010/4 31510/416 31016/4 31516/420 31020/4 31520/425 - 31525/432 31032/4 31532/440 31040/4 31540/450 31050/4 31550/463 31063/4 31563/4Measurements:Millimetres (mm) unless stated otherwiseUse the colour code to identify the supplying Proteus Division:Blue box:Proteus Consumer No box:Proteus Industrial
52PROTEUS | SINGLE MODULE RCBOs - 1 POLE & SOLID NEUTRALDOUBLE MODULE RCBOs - 1POLE & SWITCHED NEUTRALB CURVEMRBA range are suitable for ‘cable in-cable out’ applications and with DP comb busbar.XL6BRB CURVEC CURVE20MCRSPKB CURVE10MRBERESIDUAL CURRENT BREAKER WITH OVERLOAD* - 4.5kA rating. **- 6kA rating.* - 4.5kA rating. **- 6kA rating.Measurements:Millimetres (mm) unless stated otherwiseUse the colour code to identify the supplying Proteus Division:Blue box:Proteus Consumer No box:Proteus IndustrialRCBOs and RCDs: Are fitted with a ‘Test-Button’ facility which will check the detection and mechanical tripping function of the device, this must be operated regularly.Circuit Protection DevicesCURRENT RATING (A)6 kA CAT. NO. 6 kA COMP. CAT. NO.6 kA CAT. NO. 10 kA CAT. NO.10 kA COMP.CAT. NO.6 6MBRSPA 6MBRSPKA 66MBRSP XL6BR XL6BRK10 10MBRSPA 10MBRSPKA 106MBRSP XL10BR XL10BRK16 16MBRSPA 16MBRSPKA 166MBRSP XL16BR XL16BRK20 20MBRSPA 20MBRSPKA 206MBRSP XL20BR XL20BRK25 25MBRSPA 25MBRSPKA - - XL25BRK32 32MBRSPA 32MBRSPKA 326MBRSP XL32BR XL32BRK40 40MBRSPA 40MBRSPKA* 406MBRSP XL40BR XL40BRK**45 45MBRSPA 45MBRSPKA* - XL45BR -CURRENT RATING (A)6 kA CAT. NO.6 kA COMP. CAT. NO.6 kA CAT. NO.10 kA CAT. NO.10 kA COMP.CAT. NO.6 6MCRSPA 6MCRSPK 66MCRSP XL6CR XL6CRK10 10MCRSPA 10MCRSPK 106MCRSP XL10CR XL10CRK16 16MCRSPA 16MCRSPK 166MCRSP XL16CR XL16CRK20 20MCRSPA 20MCRSPK 206MCRSP XL20CR XL20CRK25 - 25MCRSPK - XL25CR XL25CRK32 32MCRSPA 32MCRSPK 326MCRSP XL32CR XL32CRK40 40MCRSPA 40MCRSPK* 406MCRSP XL40CR XL40CRK**45 45MCRSPA 45MCRSPK* - XL45CR -CURRENT RATING (A) 6 kA CAT. NO.6 6MRBA10 10MRBA16 16MRBA20 20MRBA32 32MRBA40 40MRBATYPE A TYPE A TYPE A SINGLE MODULE RCBOs - 1 POLE & SOLID NEUTRALSINGLE MODULE RCBOs - DOUBLE POLECURRENT RATING (A) 6 kA B CURVE COMP. CAT. NO.6 kA C CURVE COMP. CAT. NO.6 1BK6 1CK610 1BK10 1CK1016 1BK16 1CK1620 1BK20 1CK2032 1BK32 1CK3240 1BK40 1CK401BK10TYPE A
53 | PROTEUSPROTEUSIP3X STEEL ENCLOSURE TO SUIT 4 POLE RCDCAT. NO. H W DENCRCD4P 385 205 116CURRENT RATING (A)MAX. CABLE SIZE mm230 mA SENSITIVITY CAT. NO.100 mA SENSITIVITY CAT. NO.300 mA SENSITIVITY CAT. NO.500 mA SENSITIVITY CAT. NO.25 35 25/2/30T 25/2/100T 25/2/300T 25/2/500T40 35 40/2/30T 40/2/100T 40/2/300T 40/2/500T63 35 63/2/30T 63/2/100T 63/2/300T 63/2/500T80 35 80/2/30T 80/2/100T 80/2/300T 80/2/500T100 50 100/2/30T 100/2/100T 100/2/300T 100/2/500TCURRENT RATING (A)MAX. CABLE SIZE mm230 mA SENSITIVITY CAT. NO.100 mA SENSITIVITY CAT. NO.25 35 25/2/30TA 25/2/100TA 40 35 40/2/30TA 40/2/100TA63 35 63/2/30TA 63/2/100TA80 35 80/2/30TA 80/2/100TA100 50 100/2/30TA -CURRENT RATING (A)MAX. CABLE SIZE mm230 mA SENSITIVITY CAT. NO.100 mA SENSITIVITY CAT. NO.300 mA SENSITIVITY CAT. NO.25 35 25/4/30A - -40 35 40/4/30A 40/4/100A -63 35 63/4/30A 63/4/100A -80 35 80/4/30A 80/4/100A -100 35 100/4/30A 100/4/100A 100/4/300ACURRENT RATING (A)MAX. CABLE SIZE mm2RCD SENSITIVITY (mA)DIRECTIONALCAT. NO.BI-DIRECTIONALCAT. NO.100 (1P+N) 50 100 100/2/100D -100 (3P+N) 35 100 - 100/4/100TD100 (3P+N) 35 300 - 100/4/300TDRESIDUAL CURRENT DEVICE25/2/30TDIRECTIONAL TYPE AC 2 POLE RCDs25/2/30TABI-DIRECTIONAL TYPE A 4 POLE RCDsBI-DIRECTIONAL TIME DELAY RCDsType S - Time delay >150ms.25/4/30A100/2/100DSupply can be connected to top or bottom terminals.DIRECTIONAL TYPE A 2 POLE RCDsMeasurements:Millimetres (mm) unless stated otherwiseUse the colour code to identify the supplying Proteus Division:Blue box:Proteus Consumer No box:Proteus IndustrialRCBOs and RCDs: Are fitted with a ‘Test-Button’ facility which will check the detection and mechanical tripping function of the device, this must be operated regularly.Circuit Protection DevicesTYPE AC TYPE A TYPE A CURRENT RATING (A)MAX. CABLE SIZE mm2RCD SENSITIVITY (mA)2 POLECAT. NO.4 POLECAT. NO.63 35 30 63/2/30B 63/4/30BTYPE B RCDs63/2/30B
54PROTEUS | CURRENT RATING (A)KA RATING B CURVE CAT. NO.C CURVE CAT. NO.6 6 AFR06B1 AFR06C110 6 AFR10B1 AFR10C116 6 AFR16B1 AFR16C120 6 AFR20B1 AFR20C132 6 AFR32B1 AFR32C140 6 AFR40B1 AFR40C1COMPLETE CIRCUIT PROTECTIONARC FAULT DETECTION DEVICESAn arc-fault occurs when loose or corroded connections make intermittent contact and causes sparking or arcing between the connections. This translates into heat, which will break down the insulations of the wire and potentially trigger an electrical fire. Such arc’s can range in power and vary a great deal in strength and duration. Potential causes of arc faults could include:-WHAT IS AN ARC FAULT?WHAT IS AN AFR?The Proteus AFR is an arc fault detection device combined with short circuit, overload and earth leakage detection.Trapped/damaged cablesCable wear Damage caused by construction workLoose terminationsArc Fault Detection Devices use digital electronics to analyse the waveform of an A.C. circuit to detect arc faults. The device continuously monitors the circuit for different variations including the duration of an arc and the waveform. Once the device detects an irregular fault the device trips and disconnects the circuit, reducing the chance of it over heating and potentially causing an electrical fire.WHAT IS AN AFDD?PARALLEL ARC FAULT SERIES ARC FAULTSeries arc faults are found in loose terminal connections, damaged cords or frayed/damaged conductors. These arc’s are created in one conductor only, either phase or neutral.Parallel arc faults are found with damage caused to insulation which allows current to flow between conductors, usually between phase and neutral.AFR10B1Circuit Protection DevicesMCBRCDAFREARTH LEAKAGERCBOARC FAULTOVERCURRENTSHORT CIRCUITAFDDMCBProtection against overcurrent and short circuitRCDProtection against earth leakageRCBOProtection against overcurrent, short circuit and earth leakageAFDDProtection against arc faultAFRComplete comprehensive circuit protectionMeasurements:Millimetres (mm) unless stated otherwise• 6-40 A Rated• Series and parallel arc fault detection• 30 mA earth leakage Type A• B and C curve tripping characteristics• Switched Live & Neutral• Fits existing busbar system• Self testing (AFDD function only)Proteus offer a range of combined Arc Fault Detection (AFD) and Residual Current Circuit Breaker with Overload (RCBO) devices in B & C curve with Type A 30mA earth leakage.The single module device is designed to fit single and three phase distribution boards without the need to modify the bus bar fixing.
55 | PROTEUSPROTEUSSurge Protection DevicesSURGE PROTECTION DEVICESSurges are short-term high voltage impulses, other names being, transients, glitches and spikes, these show themselves for a very short duration of time, typically some micro seconds.Remember, it doesn’t need a direct lightning strike on an installation to cause damaging voltage surges – a ground strike in the near vicinity is quite sufficient. Also remember there are many other sources of voltage transients, such as the starting of large motors and the switching of large capacitive and inductive loads. Common examples of internal switching events are a lift motor in a hotel or fluorescent strip lights being turned on or off.WHAT ARE SURGES AND HOW ARE THEY PRODUCED?443.4 - Protection against transient overvoltage's shall be provided where the consequence caused by overvoltage…• Results in serious injury to, or loss of, human life, or• Public services or damage to cultural heritage, or• Commercial or industry activity, or• A large number of co-located individualsFor all other cases, a risk assessment according to Regulation 443.5 shall be performed in order to determine if protection against transient overvoltage is required.If the risk assessment is not performed, the electrical installation shall be provided with protection against transient overvoltage, except for single dwelling units where the total value of the installation and equipment therein does not justify such protection.• Chapter 44 - Protection against overvoltage’s of atmospheric origin or due to switching.• Chapter 53 - Devices for protection against overvoltageWHERE IS IT IN THE REGS?REG: Consequences:(a) - Serious injury to, or loss of, human life, or(b) - Interruption of public services and/or damage to cultural heritage, or(c) - Interruption of commercial or industrial activity, or(d) - Affects a large number of co-located individualsNote: CRL value <1000 = fit SPDs CRL value >1000 = No SPD required* - Refer to BS EN 62305 Risk AssessmentSPD SELECTION CHARTYes NoIs there a (LPS) Lightning Protection System Installed?Does the consequence of overvoltage result in (a) to (d)?(See below)Carry out Risk Assessment to 443.5 to determine CRL valueYesNoFit type 1 / 2 combined SPDsFit type 2 SPDs at all cable entering buildingFit type 2 at all further zonal interfaces’ and all DBs greater than 10m awayFit type 3 SPDs for sensitive equipmentTYPES OF LIGHTNING AND SURGE ARRESTORSType 1 – Surge arrestor for protection against lightning strikes.Surge arrestor for protection against man-made surges.Surge arrestor for socket outlets / strips and other sensitive control panels (i.e. intruder alarms, fire panels).Type 3 – Type 2 –RATING OF SURGE PROTECTION DEVICESType 1 devices, Maximum Impulse Current 100kA. (25kA per module)Type 2/3 devices, Maximum Discharge Current 12.5kA.Nominal Discharge Current – the device must be able to withstand a current of this magnitude 20 times without damage.Voltage protection level, is the voltage that will appear across the terminals of the device when it is carrying the nominal discharge current. Typical value is 1.5 kV.Maximum Continuous Operating Voltage. This is the maximum RMS that can be applied to the terminals of the device without causing excessive leakage current to flow.Uc- Up-In-Imax-Iimp - Measurements:Millimetres (mm) unless stated otherwise
56PROTEUS | SPD/T12/4P SPD/T12/100KA/4P SPD/T12Designation according to EN 61643-11 Type 1+2 Type 1+2 Type 1+2Nominal voltage AC 50-60 Hz Un [V] 230/400 230/400 230/-Maximum continuous operating voltage (L-N) Uc (L-N) [V] 275 275 275Lightning impulse current (10/350) (L-N) limp (L-N) [kA] 12,5 25 12,5Lightning impulse current (10/350) (N-PE) limp (N-PE) [kA] 50 100 25Maximum discharge current (8/20) (L-N) Imax (L-N) [kA] 50 100 50Maximum discharge current (8/20) (N-PE) Imax (N-PE) [kA] 50 100 50Nominal discharge current (8/20) (L-N) In (L-N) [kA] 20 25 20Nominal discharge current (8/20) (N-PE) In (N-PE) [kA] 50 50 25Voltage protection level (L-N) at In Up (L-N) [kV] ≤1,3 1,5 ≤1,3Maximum back-up fuse A [gL] 250 315 200Short circuit withstand Icc [kA] 25 25 25SPD TYPENO. of POLESTHREE PHASE CAT. NO.1 + 2 4 SPD/T12/4P1 + 2 4 SPD/T12/4PA*THREE PHASE TYPE 1 + 2 SPDSPD TYPENO. of POLESTHREE PHASE CAT. NO.1 + 2 4 SPD/T12/100KA/4PTHREE PHASE TYPE 1 + 2 SPDSPD TYPENO. of POLESSINGLE PHASE CAT. NO.1 + 2 2 SPD/T12SINGLE PHASE TYPE 1 + 2 SPDSURGE PROTECTION DEVICESSPD’S IN INSULATED IP RATED ENCLOSURESSPD TYPE IP RATING CAT. NO. H W D1+ 2 IP65 SPD/T12/4PE 155 115 951 + 2 IP65 SPD/T12/100KA/4PE 190 250 1202 IP65 SPD/T2/4PE 155 115 951 + 2 IP65 SPD/T12E 150 100 1002 IP65 SPD/T2E 150 100 1002 + 3 IP65 SPD/T23E 150 100 100SPD/T2/4PESurge Protection DevicesMeasurements:Millimetres (mm) unless stated otherwiseUse the colour code to identify the supplying Proteus Division:Blue box:Proteus Consumer No box:Proteus Industrial* - Fitted with an aux contact for remote signalingSPD/T12/4P
57 | PROTEUSPROTEUSSPD/T2/4P SPD/T2 SPD/T23Designation according to EN 61643-11 Type 2 Type 2 Type 2+3Nominal voltage AC 50-60 Hz Un [V] 230/400 230/- 230/-Maximum continuous operating voltage (L-N) Uc (L-N) [V] 275 275 275Maximum discharge current (8/20) (L-N) Imax (L-N) [kA] 40 40 15Nominal discharge current (8/20) (L-N) In (L-N) [kA] 20 20 5Voltage protection level (L-N) at In Up (L-N) [kV] ≤1,3 ≤1,3 ≤1,2Voltage protection level (N-PE) at In Up (N-PE) [kV] ≤1,5 ≤1,5 ≤1,5Maximum back-up fuse A [gL] 250 125 63Short circuit withstand Icc [kA] 25 25 10SPD TYPENO. of POLESTHREE PHASE CAT. NO.2 4 SPD/T2/4P2 4 SPD/T2/4PA*THREE PHASE TYPE 2 SPDSPD TYPENO. of POLESSINGLE PHASE CAT. NO.2 2 SPD/T2SINGLE PHASE TYPE 2 SPDSPD TYPENO. of POLESSINGLE PHASE CAT. NO.2 + 3 2 SPD/T23SINGLE PHASE TYPE 2 + 3 SPDSURGE PROTECTION DEVICESSPD’S IN STEEL ENCLOSURESSPD TYPEIP RATING CAT. NO. H W D2 IP3X SPD/T2/4PES 385 205 1161+2 IP3X SPD/T12/4PES 385 205 1161 + 2 IP3X SPD/T12/100KA/4PES 385 205 116SPD/T12/4PESSurge Protection DevicesMeasurements:Millimetres (mm) unless stated otherwiseUse the colour code to identify the supplying Proteus Division:Blue box:Proteus Consumer No box:Proteus IndustrialDESCRIPTION CAT. NO. H W D TERMINAL CAPACITY (UP TO)100A isolator with Type 2 surge protectionEMIST2 145 95 82 50 mm2100A isolator with Type 1+2 surge protectionEMIST12 145 95 82 50 mm2SURGE PROTECTED ELECTRICITY METER ISOLATOR SWITCHESEMIST2* - Fitted with an aux contact for remote signalingPre-made insulated Bus bar ConnectionsSPD/T2/4P
58PROTEUS | Proteus EVSTANDARD DISTRIBUTION UNITS FOR EV CHARGERSGENERAL CONSTRUCTION TO BSEN 61439-1 & 2Proteus Switchgear offer a wide range of standard products which suit a variety of EV installations. Not only do they distribute power, offer short circuit, overcurrent and earth leakage protection, but they are also off-the-shelf items which makes them a quick and affordable option.They are a complete solution which comes fully assembled and with all the required devices already fitted.We offer a 1 way unit, all the way up to a 12 way unit and many different configurations in-between. Outgoing ways are described as the kW rating of the required chargers so you can easily choose the switchgear to match your EV charging requirements.Proteus offer a large range of custom designed single & three phase distribution units for EV chargers. Ensure your customer’s exact requirements are met with a completely bespoke solution.PROTEUS DISTRIBUTION UNITS FOR ELECTRIC CAR CHARGERSWhether the installation is for electric car charger for home or work or if it requires a slow unit, fast charger or rapid charger, Proteus can offer a standard or bespoke solution to supply and protect your electric car charging stations.DOMESTIC, COMMERCIAL, INDUSTRIAL OR PUBLICProteus can offer EV charging switchgear solutions for a variety of installations from charging at home, the workplace, public access and commercial applications.COMPATIBILITY WITH DIFFERENT CHARGERS
59 | PROTEUSPROTEUSProteus EVEnsure your customer’s exact requirements are met with a completely bespoke solution.ON-SITE SURVEYOur team are happy to visit your site to establish your project requirements.DESIGNED TO YOUR SPECIFICATIONProteus utilise the latest drawing software and provide board layout drawings at both quotation and construction stages.TESTING & COMPLIANCEAll products tested to relevant British & European Standards.You’re welcome to visit the factory to see your board being built and discuss build requirements.Proteus Switchgear also offer pre-built bespoke solutions including MCCBs, MCBs, RCDs, RCBOs in IP3X steel enclosures or steel/GRP IP65 Enclosures to suit various applications.Not all EV charging installations are exactly the same, so specialist solutions are often required. Proteus Switchgear are able to design and build bespoke configurations to distribute power and offer protection to all of your required EV charging points.BESPOKE DISTRIBUTION UNITS FOR EV CHARGERSGENERAL CONSTRUCTION TO BSEN 61439-1 & 2With state-of-the-art manufacturing facilities and dedicated sales, technical and production staff, we specialise in offering solutions to problems that often cannot be addressed by standard product offerings.Proteus Industrial Switchgear are working with major names in electric vehicle (EV) charging. They design and build bespoke and standard switchgear solutions for protecting and distributing power to EV chargers.A recent project saw a roll-out of 150kW chargers across 6,500 public charging points throughout the UK. The roll-out will help future-proof the UK’s charging facilities, as currently very few EVs are capable of charging at 150kW.To provide suitable power distribution, control and circuit protection Proteus Industrial designed and manufactured a range of products to cover the various installation types.The main panels for the 150kW Ultra Chargers include 1250A or 1600A incomers supplying two or four 315A MCCBs. All are fitted with type A earth leakage and surge protection with a further sub-distribution board providing lighting and maintenance outlets.As a UK manufacturer Proteus Switchgear offer such customised solutions with quality products which are fully compliant with BS 61439 parts 1 & 2.PROTEUS ASSIST THE FAST CHARGER ROLL-OUTBE INVOLVEDPROTEUS EV
60PROTEUS | PROTEUS EVProteus EVAEV40PMEOUTGOING WAYSkW RATING PROTECTION DEVICE CAT. NO. H W D1 7.2 kW RCBO 40 A AEV40PME 225 225 1191 7.2 kW RCD 63 A / MCB 40 A AEVB40PME 256 309 1196kA EV DISTRIBUTION BOARDS c/w PME FAULT DETECTIONFor 1 Single Pole EV Charger CircuitAVE40PMESOUTGOING WAYSkW RATING PROTECTION DEVICE CAT. NO. H W D1 7.2 kW RCBO 40 A AEV40PMES 225 225 1191 7.2 kW RCD 63 A / MCB 40 A AEVB40PMES 256 309 11916kA EV DISTRIBUTION BOARDS c/w PME FAULT DETECTIONFor 1 Single Pole EV Charger CircuitAVE8PME40OUTGOING WAYSkW RATING PROTECTION DEVICE CAT. NO. H W D8 7.2 kW RCBO 40 A AEV8PME40 256 417 11912 7.2 kW RCBO 40 A AEV12PME40 256 489 119ISOLATOR CONTROLLED EV CONSUMER UNITS c/w PME FAULT DETECTIONFor 1 Single Pole EV Charger CircuitAVE55PME40OUTGOING WAYSkW RATING PROTECTION DEVICE CAT. NO. H W D10 7.2 kW RCBO 40 A AEV55PME40 256 489 11916 7.2 kW RCBO 40 A AEV88PME40 256 597 119DUAL RCD EV CONSUMER UNITS c/w PME FAULT DETECTIONFor 1 Single Pole EV Charger CircuitMeasurements:Millimetres (mm) unless stated otherwiseUse the colour code to identify the supplying Proteus Division:Blue box:Proteus Consumer No box:Proteus Industrial
61 | PROTEUSPROTEUSPROTEUS EVProteus EVPEV230SP RCBOs CAT. NO. H W D3 x 40 A PEV230 269 326 1106 x 40 A PEV260 269 326 110TP 100A 4P ISOLATOR INCOMERSP MCBs 2P RCDs CAT. NO.3 x 40 A 3 x 40A PEV230RCD6 x 40 A 6 x 40 A PEV260RCDPEV260RCDSuitable For 3/6 x 7.2 kW SP EV Chargers100A TP+N POPULATED DISTRIBUTION BOARD - MAINS INCOMERSuitable For: 3/6 x 7.2 kW SP EV ChargersDimensions: 538 mm(H), 326 mm(W) & 110 mm(D)Supplied with:• 100A 4 Pole isolator• 40A C Curve 10kA SP MCBs• Type A 40A 30 mA 2 Pole RCDsSupplied with:• 100A 4 Pole isolator• Type A 40A 30 mA C Curve SP RCBOAEV40PMESIPOUTGOING WAYSkW RATING PROTECTION DEVICE CAT. NO. H W D1 7.2 kW RCBO 40 A AEV40PMEIP 201 202 1201 7.2 kW RCD 63 A / MCB 40 A AEVB40PMEIP 259 319 144IP65 6kA EV DISTRIBUTION BOARDS c/w PME FAULT DETECTIONFor 1 Single Pole EV Charger CircuitOUTGOING WAYSkW RATING PROTECTION DEVICE CAT. NO. H W D1 7.2 kW RCBO 40 A AEV40PMESIP 201 202 1201 7.2 kW RCD 63 A / MCB 40 A AEVB40PMESIP 259 319 144IP65 16kA EV DISTRIBUTION BOARDS c/w PME FAULT DETECTIONFor 1 Single Pole EV Charger CircuitAEVB40PMEIPMeasurements:Millimetres (mm) unless stated otherwiseUse the colour code to identify the supplying Proteus Division:Blue box:Proteus Consumer No box:Proteus Industrial
62PROTEUS | Measurements:Millimetres (mm) unless stated otherwiseCompliant:BS EN 61439-3Use the colour code to identify the supplying Proteus Division:Blue box:Proteus Consumer No box:Proteus IndustrialTP+N POPULATED DISTRIBUTION BOARD - MAINS INCOMER4P ISOLATOR 4P RCDS RCD TYPE CAT. NO.25A 25A A PEV1-11-IRA25A 63A B PEV1-11-IRB40A 40A A PEV1-22-IRA40A 63A B PEV1-22-IRBSuitable For: 11/22kW TP EV ChargersDimensions: 385mm(H), 205 mm(W) & 112 mm(D)Supplied with:• 4 Pole isolator• 30 mA 4 Pole RCDsTP+N POPULATED DISTRIBUTION BOARD - MCB INCOMER4P RCDS RCD TYPE 4P MCBS CAT. NO.25A A 20A PEV1-11-MRA63A B 20A PEV1-11-MRB40A A 40A PEV1-22-MRA63A B 40A PEV1-22-MRBSuitable For: 11/22kW TP EV ChargersDimensions: 385mm(H), 205 mm(W) & 112 mm(D)Supplied with:• C Curve 10kA 4 Pole MCB• 30 mA 4 Pole RCDPEV1-11-IRA PEV1-11-MRA100A TP+N POPULATED DISTRIBUTION BOARD - MAINS INCOMERSuitable For: 3 x 7.2 kW SP & 1 x 22kW TP EV ChargersDimensions: 538 mm(H), 326 mm(W) & 110 mm(D)Supplied with:• 100A 4 Pole isolator• Type A 40A 30 mA C Curve SP RCBOs• 40A C Curve 10kA TP MCBs• Type A 40A 30 mA 4 Pole RCDsSP RCBOS 3P MCBS 4P RCDS CAT. NO.3 x 40A 1 x 40A 1 x 40A PEV231100A TP+N POPULATED DISTRIBUTION BOARD - MAINS INCOMERSuitable For: 3 x 7.2 kW SP & 1 x 22kW TP EV ChargersDimensions: 538 mm(H), 326 mm(W) & 110 mm(D)Supplied with:• 100A 4 Pole isolator• 40A C Curve 10kA SP MCBs• 40A C Curve 10kA TP MCBs• Type A 40A 30 mA 2 Pole RCDs• Type A 40A 30 mA 4 Pole RCDsSP MCBS 3P MCBS 2P RCDS 4P RCDS CAT. NO.3 x 40A 1 x 40A 3 x 40A 1 x 40A PEV231RCDPROTEUS EVProteus EV
63 | PROTEUSPROTEUSMeasurements:Millimetres (mm) unless stated otherwiseCompliant:BS EN 61439-3Use the colour code to identify the supplying Proteus Division:Blue box:Proteus Consumer No box:Proteus IndustrialPROTEUS EVProteus EV200A TP+N POPULATED DISTRIBUTION BOARD - MAINS INCOMERSP RCBOS 3P MCBS 4P RCDS CAT. NO.9 x 40A 3 x 40A 3 x 40A PEV6S293Suitable For: 9 x 7.2 kW SP & 3 x 22kW TP EV ChargersDimensions: 1,045 mm(H), 410 mm(W) & 110 mm(D)Supplied with:• 200A 4 Pole isolator• Type A 40A 30 mA C Curve SP RCBOs• 40A C Curve 10kA TP MCBs• Type A 40A 30 mA 4 Pole RCDs200A TP+N POPULATED DISTRIBUTION BOARD - MAINS INCOMERSuitable For: 9 x 7.2 kW SP & 3 x 22kW TP EV ChargersDimensions: 1,380 mm(H), 410 mm(W) & 110 mm(D)Supplied with:• 200A 4 Pole isolator• 40A C Curve 10kA SP MCBs• 40A C Curve 10kA TP MCBs• Type A 40A 30 mA 2 Pole RCDs• Type A 40A 30 mA 4 Pole RCDsSP MCBS 3P MCBS 2P RCDS 4P RCDS CAT. NO.9 x 40A 3 x 40A 9 x 40A 3 x 40A PEV6S293RCD125A TP+N POPULATED DISTRIBUTION BOARD - MAINS INCOMERSP RCBOS 3P MCBS 4P RCDS CAT. NO.3 x 40A 2 x 40A 2 x 40A PEV4S125326 x 40A 2 x 40A 2 x 40A PEV4S12562Suitable For: 3/6 x 7.2 kW SP & 2 x 22kW TP EV ChargersDimensions: 655 mm(H), 410 mm(W) & 110 mm(D)Supplied with:• 125A 4 Pole isolator• Type A 40A 30 mA C Curve SP RCBOs• 40A C Curve 10kA TP MCBs• Type A 40A 30 mA 4 Pole RCDsPEV4S12532125A TP+N POPULATED DISTRIBUTION BOARD - MAINS INCOMERSuitable For: 3/6 x 7.2 kW SP & 2 x 22kW TP EV ChargersDimensions: 885 mm(H), 410 mm(W) & 110 mm(D)Supplied with:• 125A 4 Pole isolator• Type A 40A 30 mA C Curve SP RBCOs• 40A C Curve 10kA TP MCBs• Type A 40A 30 mA 2 Pole RCDs • Type A 40A 30 mA 4 Pole RCDsPEV4S12532RCDSP MCBS 3P MCBS 2P RCDS 4P RCDS CAT. NO.3 x 40A 2 x 40A 3 x 40A 2 x 40A PEV4S12532RCD6 x 40A 2 x 40A 6 x 40A 2 x 40A PEV4S12562RCD
64
Please refer to page 50 for circuit protection devicesCONSUMER UNITDIVISIONFor over 30 years, Proteus Switchgear has been at the forefront of British manufacturing - specialising in the production of domestic consumer units and circuit protective devices, working proficiently to supply a full and varied product range. In addition to our standard product range, we have the ability to offer fully bespoke units, tailored to customer needs to suit any individual installation. At Proteus, we are entirely committed to the design and development of our products with the future in mind. Our values insist that we are continuously endeavouring to provide 100% tested products alongside features and benefits that allow us to excel within the Switchgear industry.Section ContentMetalclad Consumer Units 66Insulated Consumer Units 78Proteus EV 58Enclosures/Multi-Purpose Units 81Switch Fuses/Fire Alarm Switches 82Metering Ancillary Products 84 Three Phase Consumer Units 86Mantel Units 87Circuit Protection Devices 50Timers 88Contactors & Isolators 89Accessories 90Specials 92Technical Information 9465
66PROTEUS CONSUMER | RCBO/MCBRCBO/MCBRCBO/MCBRCBO/MCBRCBO/MCBRCBO/MCBRCBO/MCBRCBO/MCBRCBO/MCBRCBO/MCBRCBO/MCBRCBO/MCBNELSPDNDPINCOMERDPRCDMCBMCBMCBMCBMCBMCBMCBMCBMCBMCBMCBNMCBESPDL NEEEESELECTION AND CONFIGURATIONS• Is the Consumer Unit being installed in a domestic (household) premise (Reg. 421.1.201), i.e. metalclad consumer unit?• To avoid hazards and minimise inconvenience in the event of a fault, take into account the danger caused by failure of a single circuit such as a lighting circuit. Reduce the possibility of tripping of an RCD due to excessive protective conductor currents (Reg. 314.1).ISOLATOR CONTROLLED BOARDRCD CONTROLLED BOARD• Allows the use of single module RCBO devices for individual circuit protection at 30 mA.• Reduces risk of nuisance tripping.• An earth fault on one circuit would not adversely affect other circuits in the installation.• Can be used as main domestic Consumer Unit.• Suitable for Grouped Circuit Protection of small numbers of circuits, usually downstream of main consumer unit.• Typical applications include garages, showers and small extensions.• If fed from main Consumer Unit also with RCD protection, earth leakage discrimination must be considered.• Can be used as sub-distribution board, but should not be used as main domestic Consumer Unit.See page 72 for Metalclad boards (82 for insulated boards)See page 73 for Metalclad boards (82 for insulated boards)Metalclad Consumer UnitsThis guide to Consumer Units has been compiled in order to assist in understanding the new wiring regulations. However it is not intended to be a substitute for BS 7671 which should always be consulted in order to ensure that all installations are constructed in accordance with these regulations.• Socket outlets up to 32A must be protected by a residual-current device (Reg. 411.3.3).• Is Lightning or Surge Protection required under Regulation 443.4 & 5?• Are Arc Fault Detection Devices (AFDDs) required to provide additional protection against fire under regulation 421.1.7?
67 | PROTEUS CONSUMERPROTEUS CONSUMERNEDPINCOMERRCBO/AFDDRCBO/AFDDRCBO/AFDDRCBO/AFDDSupplyL NSELECTION AND CONFIGURATIONSDUAL RCD BOARDHIGH INTEGRITY DUAL RCD BOARD• High Integrity circuit ways off the isolator are available for dedicated circuit protection - i.e. Smoke Alarms.• Dual 30 mA RCD configuration offering Grouped Circuit Protection.• Circuits can be segregated to reduce unwanted tripping.• Can be used as main domestic Consumer Unit.• Offers Grouped Circuit Protection using two 30 mA RCDs• Circuits can be segregated to reduce unwanted tripping, for example upstairs lights + downstairs ring main off RCD1 and downstairs lights + upstairs ring main off RCD2.• Can be used as main domestic Consumer Unit. See page 74 for Metalclad boardsSee page 75 for Metalclad boardsDUAL TARIFF BOARD• For segregation of On Peak and Off Peak circuits.• Optional split load and isolator incomer options available.• Additional configurations available upon request.• Can be used as main domestic Consumer Unit.Metalclad Consumer UnitsAFDD BOARD• For compliance to Regulation 421.1.7 - recommended use of Arc Fault Detection Devices as a means of providing additional protection against fire caused by arc faults in final AC circuits.• Use standard Isolator Controlled Consumer Units and fit 1 module combined AFD/RCBO Devices offering Arc Fault, Earth Leakage, Overload and Short Circuit protection.• Can be used as main domestic Consumer Unit.See page 56 for Combined AFD/RCBOsDPISOLATORMCBMCBMCBMCBMCBMCBMCBN1MCBESPDL NDPRCDDPRCDN2DPISOLATORMCBMCBMCBMCBMCBMCBN2ESPDL NDPRCDDPRCDN3RCBO/MCBRCBO/MCBN1See page 76 for Metalclad boardsEEEEERCBO/MCBRCBO/MCBRCBO/MCBRCBO/MCBRCBO/MCBRCBO/MCBRCBO/MCBRCBO/MCBRCBO/MCBRCBO/MCBLSPDNDPINCOMERDPINCOMERNEN NESupplyL1SupplyL2Supply NN3N2N2N1RCBORCBORCBORCBORCBORCBO
68PROTEUS CONSUMER | METALCLAD CONSUMER UNIT FEATURESMetalclad Consumer UnitsThe new range of Metalclad Consumer Units from Proteus Switchgear have been designed in conjunction with contractors and housing authorities specifically to meet the requirements of BS 7671 - The Wiring Regulations.With its linear design and matt white (RAL9010) finish, the consumer unit offers the home owner a discreet and contemporary product, whilst providing suitable protection to meet today’s need.The All-Metal construction ensures compliance to Regulation 421.1.201, whilst the optional Surge Protection feature means you are up to date with the latest 18th Edition regulations.The Proteus Metalclad range meets these requirements and offers additional features providing a more versatile product for the installing contractor.KEYFEATURES:METALCLADRANGEFEATURES:
69 | PROTEUS CONSUMERPROTEUS CONSUMERMETALCLAD CONSUMER UNIT FEATURESMetalclad Consumer UnitsIncreased height for added cabling space.OFFERING A COMPREHENSIVE RANGE1.2.Increased Height1.2.Added cabling capacity3.4.3.Easy access for meter tail connections.7.BS EN 61439-3 Compliant.6.Bespoke consumer units made to order.5.Removable blank for SPD installation.18th Edition / SPD CompliantComb bus bar / Half Din Rail for quick fitting of devices.4.Preformed cablesInstallation of Devices
70PROTEUS CONSUMER | ISOLATOR INCOMER CONSUMER UNITSThe Proteus Metalclad range of metal consumer units are designed and manufactured to BS EN 61439 pt3 and meets the requirements of BS 7671, regulation 421.1.201 - effects against thermal influences specifically for domestic household dwellings. With the addition of a removable blank adjacent to the main switch, these consumer units are 18th Edition compliant for Surge Protection Devices.AYXLM8UT2ISOLATOR CONTROLLED CONSUMER UNITSMetalclad Consumer UnitsMeasurements:Millimetres (mm) unless stated otherwiseCircuit Protection Devices:Please refer to page 52FEATURES:O/G WAYS ISOLATOR RATING WITHOUT SPDCAT. NO.H W D2 63 A AYXLM2 - 220 115 854 100 A AYXLM4U AYXLM4UT2 256 201 1196 100 A AYXLM6U AYXLM6UT2 256 273 1198 100 A AYXLM8U AYXLM8UT2 256 273 11910 100 A AYXLM10U AYXLM10UT2 256 309 11912 100 A AYXLM12U AYXLM12UT2 256 381 11914 100 A AYXLM14U AYXLM14UT2 256 381 11916 100 A AYXLM16U AYXLM16UT2 256 417 11918 100 A AYXLM18U AYXLM18UT2 256 489 11920 100 A AYXLM20U AYXLM20UT2 256 489 11926 100 A AYXLM26U AYXLM26UT2 256 597 119LIFT UPLIDS18thCOMPLIANT63 A / 100 A Double Pole Switch Disconnector Incomer Metalclad Consumer Unit• Available range of outgoing circuits from 2 to 26 way• Units will accept 6 kA and 10 kA MCBs and RCBOs• Optional Surge Protection Device (SPD) fitted• Non-combustible enclosureWITH SPDTYPE 2CAT. NO.For TYPE 1 lightning protection replace suffix T2 for T1For TYPE 2+3 overvoltage transient replace suffix T2 for T23
71 | PROTEUS CONSUMERPROTEUS CONSUMERRCD INCOMER CONSUMER UNITS* - 30 mA trip rating.RCD INCOMER CONSUMER UNITSAJBXM8UAThe Proteus range of RCD incomer metalclad consumer units are available with 63 A, 80 A and 100 A RCD incomer ratings and 30 mA earth leakage protection. For higher earth leakage protection, 100 mA to 500 mA, please contact our sales office for further details on 01527 517 117.Measurements:Millimetres (mm) unless stated otherwiseCircuit Protection Devices:Please refer to page 52 Metalclad Consumer UnitsFEATURES:O/G WAYS RCD RATING*WITHOUT SPDCAT. NO.H W D2 63 A AJBXM2UA - 220 115 854 63 A AJBXM4UA AJBXM4UAT2 256 201 1196 63 A AJBXM6UA AJBXM6UAT2 256 273 1198 63 A AJBXM8UA AJBXM8UAT2 256 273 11912 63 A AJBXM12UA AJBXM12UAT2 256 381 1192 80 A AKBXM2UA - 232 150 1194 80 A AKBXM4UA AKBXM4UAT2 256 201 1196 80 A AKBXM6UA AKBXM6UAT2 256 273 1198 80 A AKBXM8UA AKBXM8UAT2 256 273 11912 80 A AKBXM12UA AKBXM12UTA2 256 381 1192 100 A ALBXM2UA - 232 150 1194 100 A ALBXM4UA ALBXM4UAT2 256 201 1196 100 A ALBXM6UA ALBXM6UAT2 256 273 1198 100 A ALBXM8UA ALBXM8UAT2 256 273 11912 100 A ALBXM12UA ALBXM12UAT2 256 381 11963 A / 100 A 30 mA RCD Incomer Metalclad Consumer Unit • Available range of outgoing circuits from 2 to 12 way• Incoming RCD fitted can be a choice of either 63 A, 80 A, or 100 A• Units will accept 6 kA and 10 kA MCBs• Optional Surge Protection Device (SPD) fitted• Non-combustible enclosureLIFT UPLIDS18thWITH SPDTYPE 2CAT. NO.COMPLIANTFor TYPE 1 lightning protection replace suffix T2 for T1For TYPE 2+3 overvoltage transient replace suffix T2 for T23
72PROTEUS CONSUMER | Measurements:Millimetres (mm) unless stated otherwiseCircuit Protection Devices:Please refer to page 52This selection of Consumer Units offer the facility to spread the load circuits across one or two 30 mA RCDs. In addition, our standard range of dual RCD consumer units are available with SPDs pre-fitted.DUAL RCD CONSUMER UNITSAYXLMJB5JB5UAT2DUAL RCD CONSUMER UNITSMetalclad Consumer Units Dual RCD ControlledO/G WAYS ISOLATOR RATINGRCD 1 RATING*RCD 2 RATING*WITHOUT SPD CAT. NO. H W D6 100 A 63 A 63 A AYXLMJB3JB3UA AYXLMJB3JB3UAT2 256 309 11910 100 A 63 A 63 A AYXLMJB5JB5UA AYXLMJB5JB5UAT2 256 381 11910 100 A 80 A 80 A AYXLMKB5KB5UA AYXLMKB5KB5UAT2 256 381 11910 100 A 100 A 100 A AYXLMLB5LB5UA AYXLMLB5LB5UAT2 256 381 11912 100 A 63 A 63 A AYXLMJB6JB6UA AYXLMJB6JB6UAT2 256 417 11912 100 A 80 A 80 A AYXLMKB6KB6UA AYXLMKB6KB6UAT2 256 417 11912 100 A 100 A 100 A AYXLMLB6LB6UA AYXLMLB6LB6UAT2 256 417 11916 100 A 80 A 80 A AYXLMKB8KB8UA AYXLMKB8KB8UAT2 256 489 11916 100 A 100 A 100 A AYXLMLB8LB8UA AYXLMLB8LB8UAT2 256 489 11920 100 A 80 A 80 A AYXLMKB10KB10UA AYXLMKB10KB10UAT2 256 597 11920 100 A 100 A 100 A AYXLMLB10LB10UA AYXLMLB10LB10UAT2 256 597 119Metalclad Consumer UnitsFEATURES:LIFT UPLIDS18thWITH SPD TYPE 2CAT. NO.COMPLIANT• Supplied with 2x Type A 30mA RCDs, 1x 100A DP isolator and full complement of earth and neutral terminals along with marking labels, busbar and instructions• Non-combustible enclosureFor TYPE 1 lightning protection replace suffix T2 for T1For TYPE 2+3 overvoltage transient replace suffix T2 for T23
73 | PROTEUS CONSUMERPROTEUS CONSUMERMeasurements:Millimetres (mm) unless stated otherwiseCircuit Protection Devices:Please refer to page 52HIGH INTEGRITY DUAL RCD CONSUMER UNITS* - 30 mA trip rating. AYXLM2JB4JB4UAT2HIGH INTEGRITY CONSUMER UNITSDual RCD High Integrity Metalclad Consumer UnitO/G WAYS ISOLATOR RATINGRCD 1 RATING*RCD 2 RATING*WITHOUT SPD CAT. NO. H W D6 100 A 63 A 63 A AYXLM1JB2JB3UA AYXLM1JB2JB3UAT2 256 309 11910 100 A 63 A 63 A AYXLM2JB4JB4UA AYXLM2JB4JB4UAT2 256 381 11912 100 A 63 A 63 A AYXLM2JB5JB5UA AYXLM2JB5JB5UAT2 256 417 11914 100 A 63 A 63 A AYXLM2JB6JB6UA AYXLM2JB6JB6UAT2 256 489 11920 100 A 80 A 80 A AYXLM4KB8KB8UA AYXLM4KB8KB8UAT2 256 597 1196 100 A 63 A 63 A AYXLMDSLV6UA AYXLMDSLV6UAT2 256 309 11910 100 A 63 A 63 A AYXLMDSLV10UA AYXLMDSLV10UAT2 256 381 11910 100 A 100 A 100 A AYXLMDSLV10UNA AYXLMDSLV10UNAT2 256 381 11912 100 A 63 A 63 A AYXLMDSLV12UA AYXLMDSLV12UAT2 256 417 11912 100 A 100 A 100 A AYXLMDSLV12UNA AYXLMDSLV12UNAT2 256 417 11916 100 A 80 A 80 A AYXLMDSLV16UA AYXLMDSLV16UAT2 256 489 11916 100 A 100 A 100 A AYXLMDSLV16UNA AYXLMDSLV16UNAT2 256 489 11922 100 A 80 A 80 A AYXLMDSLV22UA AYXLMDSLV22UAT2 256 597 11922 100 A 100 A 100 A AYXLMDSLV22UNA AYXLMDSLV22UNAT2 256 597 119Metalclad Consumer UnitsFor applications where ‘High Integrity’ circuit protection is required, for example smoke detectors, these units allow dedicated RCBO installation.FEATURES:Standard configurations listed below supplied with DP Isolator and RCD/s factory fitted, link leads for both Live and Neutral connections also pre-installed.LIFT UPLIDSWITH SPD TYPE 2CAT. NO.18thCOMPLIANTFor TYPE 1 lightning protection replace suffix T2 for T1For TYPE 2+3 overvoltage transient replace suffix T2 for T23• Supplied with 2x Type A 30 mA RCD’s, 1x 100 A DP Isolator and full complement of earth and neutral terminals along with marking labels, bus bar and instructions• Non-combustible enclosure• DSLV units are flexible/variable
74PROTEUS CONSUMER | SPLIT LOAD CONSUMER UNITSAYXLMSLV12UAAYXLM8Y4UDUAL TARIFF CONSUMER UNITSMetalclad Consumer Units Split LoadIsolator controlled dual tariff consumer units. For RCD incomers, please contact our sales office.O/G WAYS ISOLATOR RATING RCD 1 RATING* WITHOUT SPD CAT. NO.H W D6 100 A 63 A AYXLMSLV6UA AYXLMSLV6UAT2 256 273 11012 100 A 63 A AYXLMSLV12UA AYXLMSLV12UAT2 256 381 110ON PEAK OFF PEAK WITHOUT SPD CAT. NO. H W D100 A isolator 6 ways 100 A isolator 2 ways AYXLM6Y2U AYXLM6Y2UT2 256 309 119100 A isolator 8 ways 100 A isolator 4 ways AYXLM8Y4U AYXLM8Y4UT2 256 381 119100 A isolator 8 ways 100 A isolator 6 ways AYXLM8Y6U AYXLM8Y6UT2 256 417 119100 A isolator 10 ways 100 A isolator 4 ways AYXLM10Y4U AYXLM10Y4UT2 256 417 119100 A isolator 12 ways 100 A isolator 4 ways AYXLM12Y4U AYXLM12Y4UT2 256 446 119100 A isolator 12 ways 100 A isolator 6 ways AYXLM12Y6U AYXLM12Y6UT2 256 489 119100 A isolator 10 ways 100 A isolator 10 ways AYXLM10Y10U AYXLM10Y10UT2 500 309 1193 & 3 Dual RCD 100 A isolator 2 ways AYXLMJB3JB3Y2U AYXLMJB3JB3Y2UT2 256 381 1194 & 4 Dual RCD 100 A isolator 4 ways AYXLMJB4JB4Y4U AYXLMJB4JB4Y4UT2 256 446 1195 & 5 Dual RCD 100 A isolator 4 ways AYXLMJB5JB5Y4U AYXLMJB5JB5Y4UT2 256 489 119* - 30 mA trip rating.LIFT UPLIDSLIFT UPLIDSWITH SPD TYPE 2CAT. NO.WITH SPD TYPE 2CAT. NO.18thCOMPLIANT18thCOMPLIANTFEATURES:Our standard range of dual tariff consumer units provide dedicated segregation of on peak and off peak circuits.Measurements:Millimetres (mm) unless stated otherwiseCircuit Protection Devices:Please refer to page 52DUAL TARIFF & SPLIT LOAD CONSUMER UNITSMetalclad Consumer Units• Available in bespoke configurations• Suitable for Multi-Tariff installations• Optional Surge Protection Device (SPD) fittedFor TYPE 1 lightning protection replace suffix T2 for T1For TYPE 2+3 overvoltage transient replace suffix T2 for T23• Supplied with 1 x 30 mA RCDs, 1 x 100A DP isolator and full complement of earth and neutral terminals• Units are variable / configurable• Non-combustible enclosure
75 | PROTEUS CONSUMERPROTEUS CONSUMERDUAL RCD CONTROLLED CONSUMER UNITSMetalclad Consumer Units Dual RCD Controlled• Supplied with 2x Type A 30mA RCDs, 1x 100A DP isolator and full complement of earth and neutral terminals• Non-combustible enclosureISOLATOR CONTROLLED CONSUMER UNITSO/G WAYS ISOLATOR RATING WITHOUT SPDCAT. NO.H W D22 100 A AYXLM22DBU AYXLM22DBUT2 500 301 11930 100 A AYXLM30DBU AYXLM30DBUT2 500 381 11934 100 A AYXLM34DBU AYXLM34DBUT2 500 417 11942 100 A AYXLM42DBU AYXLM42DBUT2 500 489 119100 A Double Pole Switch Disconnector Incomer Metalclad Consumer Unit• Available range of outgoing circuits from 22 to 42 way• Units will accept 6 kA and 10 kA MCBs and RCBOs• Optional Surge Protection Device (SPD) fitted• Non-combustible enclosureWITH SPDTYPE 2CAT. NO.Metalclad Consumer UnitsDOUBLE BANK CONSUMER UNITS* - 30 mA trip rating.O/G WAYS ISOLATOR RATINGRCD 1 RATING*RCD 2 RATING*WITHOUT SPD CAT. NO. H W D18 100 A 80 A 80 A AYXLMKB8KB10UA AYXLMKB8KB10UAT2 500 309 11926 100 A 80 A 80 A AYXLMKB12KB14UA AYXLMKB12KB14UAT2 500 381 11930 100 A 80 A 80 A AYXLMKB14KB16UA AYXLMKB14KB16UAT2 500 417 119WITH SPD TYPE 2CAT. NO.For TYPE 1 lightning protection replace suffix T2 for T1For TYPE 2+3 overvoltage transient replace suffix T2 for T23HIGH INTEGRITY DUAL RCD CONSUMER UNITS* - 30 mA trip rating. Dual RCD High Integrity Metalclad Consumer UnitO/G WAYS ISOLATOR RATINGRCD 1 RATING*RCD 2 RATING*WITHOUT SPD CAT. NO. H W D18 100 A 80 A 80 A AYXLM2KB6KB10UA AYXLM2KB6KB10UAT2 500 309 11926 100 A 80 A 80 A AYXLM2KB10KB14UA AYXLM2KB10KB14UAT2 500 381 11930 100 A 80 A 80 A AYXLM2KB12KB16UA AYXLM2KB12KB16UAT2 500 417 119WITH SPD TYPE 2CAT. NO.• Supplied with 2x Type A 30 mA RCD’s, 1x 100 A DP Isolator and full complement of earth and neutral terminals• Non-combustible enclosure• DSLV units are variable / configurableMore double banked configurations available on requestAYXLM22DBUT2AYXLMKB12KB14UAAYXLM2KB6KB10UAT2
76PROTEUS CONSUMER | ENCLOSURES & GARAGE / SHOWER UNITSGARAGE UNITSAPXLM10UMETALCLAD ENCLOSURESAPGU2AMeasurements:Millimetres (mm) unless stated otherwiseCircuit Protection Devices:Please refer to page 52The Proteus Metalclad range offers a selection of din rail mount enclosures for building your own switchgear assembly. Metalclad Consumer UnitsFEATURES:A range of Garage and Shower Units are also available, prefitted with MCBs and bus bar.NO. OF MODULES BANKS CAT. NO. H W D6 1 APXLM6U 256 201 11910 1 APXLM10U 256 273 11912 1 APXLM12U 256 309 11916 1 APXLM16U 256 381 11918 1 APXLM18U 256 417 11922 1 APXLM22U 256 489 11928 1 APXLM28U 256 597 119O/G WAYSRCD 1 RATING*RCD 2 RATING*CAT. NO. H W D2 40 A 6 A+16 A APGU2A 220 115 854 4 0A 6 A+16 A APGU4MUA 256 201 119Metal Clad Garage Unit with 40 A RCD with 6 A and 16 A MCB• Compact designO/G WAYSRCD 1 RATING*RCD 2 RATING*CAT. NO. H W D1 40 A 40 A APSU95A 220 115 851 63 A 50 A APSU115A 232 150 85SHOWER UNITSMetal Shower Unit complete with 40 A RCD and 40 A MCB or 63 A RCD and 50 A MCB• Non-combustible enclosureAPSU115AAENC204MLMODULAR METALCLAD ENCLOSURESNO. OF MODULES BANKS CAT. NO. H W D2 1 AENC202ML 230 67 904 1 AENC204ML 235 113 1058 1 AENC208ML 235 185 10512 1 AENC212ML 237 259 105• Centralised dinrail• Consumer unit style enclosures
77 | PROTEUS CONSUMERPROTEUS CONSUMERMETALCLAD ACCESSORIESDESCRIPTION CAT. NO. DIA2x 25 mm / 1x 16 mm M32 - brass MTGP32B 322x 25 mm / 1x 16 mm M40 - brass MTGP40B 402x 25 mm / 1x 16 mm M32 - plastic MTGP32P 322x 25 mm / 1x 16 mm M40 - plastic MTGP40P 40Meter tail reducer 40-32 mm EA40/32 -MTGP40BMETER TAIL GLAND PACKSTo compliment the Proteus range of Metalclad consumer units, a selection of spacer mounts are available for use where retrofitting to surface mount cables are necessary. FEATURES:In addition, Meter Tail glands are available for providing Class II insulation protection for incoming supply cables. Metalclad Consumer UnitsNO. OF MODULES BANKS CAT. NO. H W D6 1 ASM6 256 201 3010 1 ASM10 256 273 3012 1 ASM12 256 309 3016 1 ASM16 256 381 3018 1 ASM18 256 417 3022 1 ASM22 256 489 3028 1 ASM28 256 597 30• 30 mm deep • Aids surface cable entry• Accepts mini trunking adaptors• Supplied with fixing screwsMeasurements:Millimetres (mm) unless stated otherwiseINTUMESCENT PUTTY PADDESCRIPTION CAT. NO.Intumescent putty pad (210 mm x 148 mm x 3 mm)IP21X15ASM12CONSUMER UNIT SPACER MOUNTSFor 6 - 28 Module Metalclad BoardsFor more information contact our sales office or see below.CONSUMER UNITSPACER MOUNTASM6 ASM10 ASM12 ASM16 ASM18 ASM22 ASM28ISOLATOR CONTROLLED 4 Way 6 + 8 Way 10 Way 12/14 Way 16 Way 20 Way 26 WayRCD CONTROLLED 4 Way 6 + 8 Way 10 Way 12 Way - - -DUAL RCD - - 6 Way 10 Way 12 Way 16 Way 22 WayHIGH INTEGRITY - - 6 Way 10 Way 12 Way 16 Way 22 Way
78PROTEUS CONSUMER | INSULATED CONSUMER UNIT FEATURESInsulated Consumer UnitsThe Proteus range of insulated Consumer Units has quickly become one of the most innovative insulated boards in the market. Developed through a keen interest in customer feedback, Proteus Switchgear created a Consumer Unit that was flexible to any imaginable on-site scenario. The options available include Isolator Incomer units and also RCD Incomer units - suitable for single Phase MCBs and also RCBOs, offering complete peace of mind for those essential circuits requiring dedicated earth fault protection. KEYFEATURES:INSULATEDRANGEFEATURES:
79 | PROTEUS CONSUMERPROTEUS CONSUMERINSULATED CONSUMER UNIT FEATURESInsulated Consumer UnitsUnique stacking system.Removable endplates for maximum cable access.Half Din Rail for quick fitting of devices.OFFERING A COMPREHENSIVE RANGE1.1.StackingStacking2.Removable Endplates2.Removable EndplatesComb bus bar greater connection.3.Comb Bus Bar3.Comb Bus BarRear, side and top/bottom cable entries.4.Cable Entry4.Cable Entry5.BS EN 61439-3 Compliant.6.Increased height for added cabling space.7.Translucent front door.8.Manufactured from thermoplastic materials to BS 60695. 9.Bespoke consumer units made to order.10.
80PROTEUS CONSUMER | For Isolator controlled Consumer Units with over 30 outgoing ways contact factory for availability.* - Cannot be bankedYXL# units are supplied with translucent cover.YXL6ISOLATOR & RCD INCOMER CONSUMER UNITSISOLATOR CONTROLLED CONSUMER UNITSRCD incomer units are available in higher earth leakage sensitivity options on request.* - Insulated boards which cannot be banked.RCD CONTROLLED CONSUMER UNITS JBX4Measurements:Millimetres (mm) unless stated otherwiseCircuit Protection Devices:Please refer to page 52Insulated Consumer UnitsO/G WAYS ISOLATOR RATING (A)NO. of MODULESCAT. NO. H W D1 D22 63 4 YXL2* 230 116 110 2204 100 6 YXL4* 230 152 110 2206 100 10 YXL6 230 252 106 2058 100 10 YXL8 230 252 106 20512 100 16 YXL12 230 359 106 20514 100 16 YXL14 230 359 106 205Double Pole Switch Disconnector Incomer Insulated Consumer Unit• Outgoing circuits from 2 to 14 ways available on request• Incoming Isolators fitted range from 63 A / 100 A• Modular principle, allows limitless permutations• Original installations can be supplemented to keep pace with user requirements• Easy wiring access provided by removable endplates• Four quarter turn screws provide easy removal of front cover• Units will accept 6kA and 10kA MCBs and RCBOsO/G WAYS ISOLATOR RATING (A)NO. of MODULESCAT. NO. H W D1 D22 63 4 JBX2* 230 116 110 2204 63 6 JBX4* 230 152 110 2206 63 10 JBX6 230 252 106 2058 63 10 JBX8 230 252 106 20510 63 14 JBX10 200 320 106 20512 63 14 JBX12 200 320 106 2054 80 6 KBX4* 230 152 110 2206 80 10 KBX6 230 252 106 2058 80 10 KBX8 230 252 106 20510 80 14 KBX10 200 320 106 20512 80 14 KBX12 200 320 106 2056 100 10 LBX6 230 252 106 2058 100 10 LBX8 230 252 106 20510 100 14 LBX10 200 320 106 20512 100 14 LBX12 200 320 106 205Residual Current Device Incomer Insulated Consumer Unit• Offers a range of outgoing circuits from 2 to 12 ways• Incoming RCD fitted can be a choice of 25 A / 40 A / 63 A / 80 A / 100 A• Comes with Earth Fault sensitivity ratings of 30 mA or 100 mA• Easy wiring access provided by removable endplates• Four quarter turn screws provide easy removal of front cover• Units will accept 6kA and 10kA MCBs, RCBOs and DIN Rail mounting HRC carriers"LIFT UPLIDSGLOW WIRELIFT UPLIDS960° RATEDGLOW WIRE960° RATEDHWD1D2HWD1D2
81 | PROTEUS CONSUMERPROTEUS CONSUMERMeasurements:Millimetres (mm) unless stated otherwiseENCLOSURES/MULTI-PURPOSE UNITSMULTI-PURPOSE UNITS* - Insulated enclosures which cannot be banked.PXL4• Surface mounting units suitable for use with Proteus modular isolation and protection devices to provide local or individual circuit control eg. Workshop.* - Enclosure supplied without transparent front cover.INSULATED IP ENCLOSURESENC654• Build your own consumer unit or multi-purpose board simply clip on your required equipment to the DIN Rail and if necessary fit the Comb Busbar.• Fitted with full DIN rail, Earth and Neutral terminal bars. Enclosures/Multi-Purpose UnitsNO. of MODULES CAT. NO. H W D1 D24 PXL4* 230 116 110 2206 PXL6* 230 152 110 22010 PXL10 230 252 106 20516 PXL16 230 359 106 20518 PXL18* 230 390 110 220NO. of MODULES IP RATING CAT. NO. H W D1 or 2 20 ENC202* 135 40 654 20 ENC204* 135 75 654 40 ENC404 230 116 1104 55 ENC544 160 120 952 65 ENC652 150 100 1004 65 ENC654 200 127 1208 65 ENC658 200 200 12012 65 ENC6512 258 318 14218 65 ENC6518 259 428 14224 65 ENC6524 383 318 14236 65 ENC6536 507 318 142LIFT UPLIDSLIFT UPLIDSGLOW WIRE960° RATEDGLOW WIRE960° RATEDHWD1D2
82PROTEUS CONSUMER | Measurements:Millimetres (mm) unless stated otherwiseSwitch Fuse/Fire Alarm SwitchesSWITCH FUSE & FIRE ALARM SWITCHESDOUBLE POLE HRC SWITCH FUSESDP Isolator can be locked in the ON or OFF position using DLPX1.FIRE ALARM PANEL SWITCH• Compliant with B5839 pt 1-2002 & BSEN 54 pt4-1997• Three module steel enclosure.• 45 A DP Isolator and 6 A Type B SP MCB fitted• Both devices can be locked in the ‘ON’ position using locking accessories supplied.• Surface mounted c/w top and bottom knockouts.• Ingress protection: IP20.• Surface mounting switch disconnector fuse unit in robust steel enclosure. • Powder coated paint finish. SF20FEATURES:CURRENT RATINGCAPACITY IN (mm2)CAPACITY OUT (mm2)CAT. NO. H W D20 50 25 SF20 225 114 9032 50 25 SF32 225 114 9040 50 25 SF40 225 114 9050 50 25 SF50 225 114 9063 50 25 SF63 225 114 9080 50 50 SF100/80 307 192 93100 50 50 SF100 307 192 9320 - 100 A Single Pole Plus Neutral Switch Complete With High Rupture Capacity Fuse• Top Hinged Steel Door• Incorporating DP isolator and BS88 fuse all enclosed in a robust metal clad enclosure• Isolation switch can be locked in ON or OFF position• Tough polyester epoxy paint coatingDESCRIPTION CAPACITY IN (mm2)CAPACITY OUT (mm2)CAT. NO. H W DMetalclad unit 50 25 FS1 175 110 85NB: MCB will trip under fault conditions even when lock is fitted.For Use When Connecting A Fire Alarm To A Public Or Private Power Distribution Supply. • Unit is designed to accommodate fuse links to BS 88: Part 1,2 & 6.• All switches are lockable in ON or OFF position.
83 | PROTEUS CONSUMERPROTEUS CONSUMERProteus offer a large range of custom designed, bespoke LV switchboards, panelboards, distribution boards and consumer units. Ensure your customer’s exact requirements are met with a completely bespoke solution.Designed to Your SpecificationOn-Site SurveyTesting & ComplianceBe involvedOur team are happy to visit your site to establish your project requirementsProteus utilise the latest drawing software and provide panel layout drawings at both quotation and construction stagesAll products tested to relevant British & European Standards and the 18th Edition Wiring RegulationsYou’re welcome to visit the factory to see your board being built and discuss build requirementsBESPOKE POWER DISTRIBUTION CONFIGURATIONSFROM PROTEUSServices
84PROTEUS CONSUMER | METERING ISOLATORS & TERMINALSEMISSINGLE & 3 PHASE ISOLATORSProteus Switchgear offer a comprehensive range of ancillary products specifically developed for the metering industry, featuring single and three phase isolators, heating contactors and terminal blocks.KILOWATT HOUR METERSKWH100AMIDMeasurements:Millimetres (mm) unless stated otherwiseMetering Ancillary ProductsFEATURES:DESCRIPTION CAT. NO. H W D TERMINAL CAPACITY (UP TO)100 A 1 P+N isolator EMIS 145 59 82 35 mm2100 A 1 P+N isolator - LHS neutral EMISN 145 59 82 35 mm224 Hr/Off peak EMIS2 145 95 82 35 mm224 Hr/Off peak - coupled neutrals EMIS2NB 145 95 82 35 mm2100 A 2 P+N isolator EMIS3 145 95 82 35 mm2100 A 3 P+N isolator EMIS4P 145 95 82 35 mm2100 A 3 P+N isolator - LHS neutral EMIS4PN 145 95 82 35 mm2Our Meter Isolator Switches offer unrivalled performance and safety for metering applications. Hosting a number of unique features, these switches provide increased connectivity for meter tail connections.DESCRIPTION CAT. NO. NO. of MODULES45 A Direct connect MID approved kWh meterKWH45AMID 1100 A Direct connect MID approved kWh meterKWH100AMID 2EMIS4PUtilising a 3 mm hex drive throughout, the one-tool-fits-all design offers the installing engineer complete peace of mind. Unique patented twin screw terminal.1.Same 3 mm hex drive for all screws.2.Blanks for all cable entries includes 16 mm2 strain relief function.3.DESCRIPTION CAT. NO. H W D TERMINAL CAPACITY (UP TO)100 A isolator with Type 2 surge protectionEMIST2 145 95 82 50 mm2100 A isolator with Type 1+2 surge protectionEMIST12 145 95 82 50 mm2100 A DP SURGE PROTECTED ELECTRICITY METER ISOLATOR SWITCHESEMIST2
85 | PROTEUS CONSUMERPROTEUS CONSUMERSINGLE & 3 PHASE HEATING CONTACTORSEHC1Measurements:Millimetres (mm) unless stated otherwiseDESCRIPTION CAT. NO. H W D TERMINAL CAPACITY (UP TO)100 A heating contactor EHC1 110 90 84 35 mm2100 A heating contactor, switched live versionEHC1L 110 90 84 35 mm2100 A heating contactor, 3P version EHC3 146 195 84 35 mm2100 A heating contactor, 3P switched live versionEHC3L 146 195 84 35 mm2Our range of single and three phase heating contactors is available in two variants – a switched Live and Switched Neutral option offering control of heating systems within multi-tariff installations up to 100 A.100 A 5 WAY TERMINAL BLOCKCOLOUR CAT. NO. H W D TERMINAL CAPACITY (UP TO)Grey ETB5 64 50 40 35 mm2Blue ETB5BL 64 50 40 35 mm2Brown ETB5BR 64 50 40 35 mm2TPE Cable grommet 30044 Cable size 1.0 mm2 - 10 mm2Metering Ancillary ProductsMETERING ISOLATORS & TERMINALSUnique patented terminal design.1.Lockable cover screws.2.Dual load output terminals.3.Same 3 mm hex drive for all connections & screws.4.Our range of 100 A terminal blocks provides a quick and easy solution for making additional terminations safely. Utilising the common 3 mm hexagonal screw throughout for a one-tool-tightens-all feature, there are also optional Brown and Blue coloured units for quick and easy identification of line and neutral phases.Same 3 mm hex drive for all screws.1.Unique joining pieces.2.Optional phase/neutral coloured mouldings.3.Thermoplastic elastomer grommet for small cables.4.Cable grommets provide additional ingress protection when using smaller cables.
86PROTEUS CONSUMER | THREE PHASE CONSUMER UNITSINSULATED ENCLOSURESWhen space is limited and the installation requires a three phase distribution board, the range of Proteus TPX consumer units is the solution.A choice of 1 to 4 outgoing TP ways fed via a * - Will accept metal gland plate MGP2.** - Will accept metal gland plate MGP3.3-phase comb busbar arrangement are available in either insulated, metalclad or IP55 enclosures.All units are pre-fitted with 100A TP Isolator incomer and busbar to suit.IP55 ENCLOSURESMETAL ENCLOSURESTPXMC2TPXIPC1TPXIC4Measurements:Millimetres (mm) unless stated otherwiseCircuit Protection Devices:Please refer to page 52Three Phase Consumer UnitsFEATURES:NO. of MODULES CAT. NO. H W D1D21 TPXIC1 230 250 105 2202 TPXIC2 * 230 250 105 2203 TPXIC3 ** 200 320 105 2204 TPXIC4 ** 230 360 105 220NO. of MODULES CAT. NO. H W D1 TPXIPC1 150 190 902 TPXIPC2 190 250 1153 TPXIPC3 270 340 1304 TPXIPC4 270 340 1301 - 4 Module Triple Pole and Neutral Type B Insulated Enclosures, Top Hinged Tinted Door, IP55NO. of MODULES CAT. NO. H W D1 TPXMC1 210 230 1102 TPXMC2 225 300 1103 TPXMC3 225 300 1101 - 3 Module Triple Pole and Neutral Type B Metalclad Distribution Boards, Side Hinged Steel Door, IP30HWD1D2
87 | PROTEUS CONSUMERPROTEUS CONSUMERMANTEL CONSUMER UNITSMantel UnitsProteus offer a variety of Mantel Consumer Units (also known as skeleton or spine units) to meet and comply with the recent changes in the wiring regulations.Designed and developed with the needs of both the installer and installation conditions in mind these units offerDUAL RCD SPINE UNITSc/w 63 A DP 30 mA RCDHIGH INTEGRITY & DUAL RCD SPINE UNITSc/w 63 A DP 30 mA RCDSPLIT LOAD SPINE UNITSc/w 63 A DP 30 mA RCDSK2JB4JB4SKSLV12SKJB5JB5Key features:16 module units.Pre-wired switchgear where applicable.Clean cover plate / barrier of non-combustible material.FEATURES:O/G WAYSISOLATOR RATINGRCD 1 RATING*RCD 2 RATING*CAT. NO. H W D10 3 7 - SK3JB7 250 333 9210 4 6 - SK4JB6 250 333 9210 5 5 - SK5JB5 250 333 9210 6 4 - SK6JB4 250 333 9210 7 3 - SK7JB3 250 333 9210 up-to 7 up-to 7 - SKSLV12 250 333 92O/G WAYSISOLATOR RATINGRCD 1 RATING*RCD 2 RATING*CAT. NO. H W D8 - 4 4 SKJB4JB4 250 333 9210 - 5 5 SKJB5JB5 250 333 92O/G WAYSISOLATOR RATINGRCD 1 RATING*RCD 2 RATING*CAT. NO. H W D10 up-to 4 6 4 SKSLV6R4 250 333 9210 2 4 4 SK2JB4JB4 250 333 92Measurements:Millimetres (mm) unless stated otherwise
88PROTEUS CONSUMER | DIGITAL, MECHANICAL & STAIRCASE TIMERSDIGITAL TIMERS72STMECHANICAL TIMERSSTAIRCASE TIMERS20.031.017.545.090.013.0N 21L30.0 19.0 11.017.945.089.0LN437891062 345148.560.036.045.085.0NLML1LOADN2NLLN43NLLN43Dimensions/Terminal Arrangement*3-wire4-wireNL7 8 9 106MLOAD2 345130.017.545.090.020.0 17.0NL1322 3 417 8 9651060.048.535.045.090.0NLNM32L1LOADCH11 channel digital timer 2 channel digital timerNLM2 3 41LOADCH17 8 96CH2LN510242SQ1SCTA range of digital, mechanical & staircase timers available in 24-hour or 7-day options, Measurements:Millimetres (mm) unless stated otherwiseTimersFEATURES:NO. of CHANNELS CURRENT RATING (A)RESISTIVE LOADCAT. NO. MODULE SIZE1 16 71ST 12 16 72ST 2Wiring Schematic And Dimensions/Terminal Arrangement*NO. of CHANNELS CAT. NO. MODULE SIZE1 Channel 24 hr synchronous timer 16A rated 241S 12 Channel 24 hr synchronous timer 16A rated 242S 22 Channel 24 hr quartz timer 16A rated 242SQ 21 NO contact 24 hr 1 Changeover contact 24 hrWiring Schematic And Dimensions/Terminal Arrangement*NO. of CHANNELS CAT. NO.Staircase timer switch 1 module 1SCTpredetermining the scheduling of automated switching options.Adjustable 30 seconds to 20 minutes.*-Please check the wiring instructions supplied with your device.
89 | PROTEUS CONSUMERPROTEUS CONSUMERCONTACTOR & ISOLATORS ISOLATORS65.549.544.060.053.435.745.084.51 3 5A1A1A2A271 3 5 72 4 6 82 4 6 865.850.044.560.318.345.581.54213A1A2Proteus contactors are available from 20A up-to 63A in 2 pole and 4 pole options, suitable for din-rail mounting in consumer units fitted with full standard din-rail.Contactors offer method of remote switching of 66.049.843.572.570.017.5 35.0 52.545.085.0• Choice of current ratings from 45A up to 100A. • Operating dolly can be locked in ON or OFF state.• Neutral pole designed to ‘make first / break last’.• Positive contact status indication therefore can be used as an isolating switch.• Switch disconnector is designed to accept cable-in/cable-out and direct to busbar connection.loads and are suitable for AC1 switching - general heating and lighting loads.Contactors are available with normally open (NO) or normally closed (NC) contacts.Standard: EN61095.CONTACTORS - NORMALLY OPEN230V COIL CT202100S2CT202NCContactors & IsolatorsMeasurements:Millimetres (mm) unless stated otherwiseCURRENT RATING (A)VOLTAGE RATING (V)POWER AT RATED VOLTAGE AC 1 (kW)POWER AT RATED VOLTAGE AC 3 (kW)NO. of POLESNO. of MODULESCAT. NO.20 400 4 - 2 1 CT20220 400 16 4 4 2 CT20440 400 25 8 4 3 CT40440 400 25 8 4 3 CT404D*63 400 37 15 4 3 CT634FEATURES:2 pole contactor4 pole contactorDimensions/Terminal Arrangement65.549.544.060.053.435.745.084.51 3 5A1A1A2A271 3 5 72 4 6 82 4 6 865.850.044.560.318.345.581.54213A1A2CONTACTORS - NORMALLY CLOSED 230V COILCURRENT RATING (A)VOLTAGE RATING (V)POWER AT RATED VOLTAGE AC 1 (kW)POWER AT RATED VOLTAGE AC 3 (kW)NO. of POLESNO. of MODULESCAT. NO.20 400 4 - 2 1 CT202NC20 400 16 4 4 2 CT204NC40 400 25 8 4 3 CT404NC63 400 37 15 4 3 CT634NC2 pole contactor4 pole contactorDimensions/Terminal ArrangementCURRENT RATING (A) DP CAT. NO. TP CAT. NO. 4P CAT. NO.45 45S2 45S3 -63 63S2 63S3 63S4100 100S2 100S3 100S4*-DC rectified coil
90PROTEUS CONSUMER | ACCESSORIES80A max. 100A intermittent rating.CB19SPMeasurements:Millimetres (mm) unless stated otherwiseAccessoriesDESCRIPTION CAT. NO.Blanking plate B1DESCRIPTION CAT. NO.Blanking module BM1DESCRIPTION CAT. NO.Busbar terminal shroud BBS1BLANKING MODULEBUSBAR TERMINAL SHROUDBLANKING PLATEDESCRIPTION CAT. NO.19 Ways, single pole CB19SP28 Ways, single pole CB28SPINSULATED COMB BUSBARSSINGLE POLECB8DPDESCRIPTION CAT. NO.8 Ways, double pole CB8DP12 Ways, double pole CB12DPINSULATED COMB BUSBARSDOUBLE POLECB7TPDESCRIPTION CAT. NO.7 Ways, triple pole CB7TP12 Ways, triple pole CB12TPINSULATED COMB BUSBARSTRIPLE POLECBC3DESCRIPTION CAT. NO.End Cap For DP/TP Insulated comb busbarCBC3END CAPCBCT1DESCRIPTION CAT. NO.Cable terminal for insulated comb busbarCBCT1CABLE TERMINAL80A max. 100A intermittent rating.80A max. 100A intermittent rating. 80A max. 100A intermittent rating.DESCRIPTION CAT. NO.2 Module blanking plate MB2METAL BLANKING PLATE
91 | PROTEUS CONSUMERPROTEUS CONSUMERACCESSORIESTB8AccessoriesMeasurements:Millimetres (mm) unless stated otherwiseDESCRIPTION CAT. NO.MCB Dolly locking device DLPX1MCB Dolly locking device c/w padlockDLPX1PDLPX1PLOCKING DEVICESDESCRIPTION CAT. NO.5 Hole terminal bar TB58 Hole terminal bar TB8BRASS TERMINAL BARSTB12DESCRIPTION CAT. NO.10 Hole terminal bar TB1012 Hole terminal bar TB12BRASS TERMINAL BARSTB16DESCRIPTION CAT. NO.14 Hole terminal bar TB1416 Hole terminal bar TB16BRASS TERMINAL BARSPMS32DESCRIPTION CAT. NO.20A BS88 HRC Fuse PMS2032A BS88 HRC Fuse PMS32BS88 FUSESPMS63DESCRIPTION CAT. NO.40A BS88 HRC Fuse PMS4050A BS88 HRC Fuse PMS5063A BS88 HRC Fuse PMS63BS88 FUSESPMS100DESCRIPTION CAT. NO.63A BS88 HRC Fuse (Fits SF100 & SF100/80)PMS6380A BS88 HRC Fuse PMS80100A BS88 HRC Fuse PMS100BS88 FUSES
92PROTEUS CONSUMER | At Proteus, our custom build service ensure we design and manufacture a diverse range of insulated and metalclad consumer units to meet your specific requirements. Larger than average homes require larger than the average Consumer Units, building bulk quantities to specification is made simple when specifying Proteus Switchgear.STREET LIGHTING APPLICATIONSSpecial locations often require special solutions. A street lighting application demanded a compact unit incorporating Double Pole RCBO, a 2 pole contactor and a 7 day digital timer. Proteus Switchgear were able to offer a pre-cabled and configured unit with electrical noise suppression component included to meet this customers specification.MULTIPLE BANKED UNITSBESPOKE UNITS• Insulated, IP rated or metalclad units.• Multiple distribution options.• Optional circuit control devices.• Pre-wired short circuit protective devices.• Fully tested assembly.MANUFACTURETECHNICAL SUPPORTDESIGNCUSTOMER BUILT CONSUMER UNITSSpecials
93 | PROTEUS CONSUMERPROTEUS CONSUMERCUSTOMER BUILT CONSUMER UNITSSpecialsOur range of RCD and RCBO devices undergo 100% electronic testing to ensure each device trips within the required time parameters.Each device is given a unique code following testing for complete traceability.RCD/RCBO TESTINGAs part of our UK testing facility, thermal testing of miniature circuit breakers and RCBO devices ensure our products meet the performance requirements of BS EN 60898.THERMAL TESTING
94PROTEUS CONSUMER | TECHNICAL INFORMATIONProteus MCBs are of thermo-magnetic, current limiting type and are available in a range of kA ratings (6kA up to 10kA) and operating characteristics (B, C and D Curve). A selection of SP (single pole), DP (double pole), TP (triple pole) and 4P (four pole) options are offered. 12060201052130105210.50.20.10.050.020.010.0050.0020.0010.0005Seconds Minutes1 2 3 4 5 6 7 8 10 15 20 30 40 50I / InB C D23 4 5 6 7 81TERMINAL CAPACITIESGENERAL SPECIFICATION1Steady current value 1.13xIn: t>1hrAll MCBs are capable of carrying full load current continuously (derating factors apply for ambient conditions and no. of circuits within an enclosure).Steady current value 1.45xIn: t<1hrAs load current increases above current rating the thermal release mechanism will disconnect MCB.B-CURVED-CURVEC-CURVE3xIn: 0.1sec<t<45sec (In<=32A)3xIn: 0.1sec<t<90sec (In>32A)MCB will trip within times specified.5xIn: t<0.1secB Curve MCB ensured to trip in less than 0.1sec via magnetic release.5xIn: 0.1sec<t<15sec (In<=32A)5xIn: 0.1sec<t<30sec (In>32A)MCB will trip within times specified.t = Tripping time10xIn: 0.1sec<t<4sec (In<=32A)10xIn: 0.1sec<t<8sec (In>32A)MCB will trip within times specified.20xIn: t<0.1secD Curve MCB ensured to trip in less than 0.1sec via magnetic release.10xIn: t<0.1secC Curve MCB ensured to trip in less than 0.1sec via magnetic release.MCB INSTALLATION VOLTAGESB & C Curve 1 pole 230V AC B & C Curve Multi-pole 400V ACTechnical Information• All MCBs have a ‘trip free mechanism’.• Positive contact status indication in accordance with IEE wiring regulations.• Tunnel design, touch proof and captive terminals.• Can be used as isolating switches.• Lockable in both ON and OFF state without affecting the ability of the trip mechanism to operate.STANDARDS: BSEN 60898OPERATING VOLTAGE: 230 / 400V a.c.OPERATING FREQUENCY: 50HzAMBIENT OPERATING TEMP.: -5°C to +40°CMAXIMUM TERMINAL TORQUE: 2.5NmENCLOSURE MATERIAL: V0 rated Polyamide (self extinguishing at 960C)SUPPLY: Can be supplied from top or bottom.IP RATING: IP4X (front face) IP20 (terminals)DIELECTRIC VOLTAGE: 2500V a.c.INSULATION VOLTAGE: 500V a.c.CURVE INSTANTANEOUS TRIPPING RANGECIRCUIT APPLICATIONSB 3 - 5 Used in domestic situations where maximum sensitivity is required and very little equipment with high start-up current is connected.C 5 - 10 Suitable for commercial / industrial situations where close protection is not required and start up currents of devices can run upto 5 times rated current for a short period. Where many low voltage lights are used in a domestic situation then, due to the inrush currents of the transformers, C Curve MCBs may be required to avoid nuisance tripping.D 10 - 20 Suitable for industrial application where start-up currents may be up to 10 times rated current, for example protection for machines with electric motors fitted, welding units etc.2345678RANGE OF MCBs CAPACITY MCBs 25 mm2 (In and Out)RCBOs 25 mm2 (In) ; 16 mm2 (Out)RCDs (<100A) 50 mm2 (In and Out)RANGE OF MCBs CAPACITY RCDs (100A) 50 mm2 (In and Out)Isolators 50 mm2 (In and Out)Earth and Neutral bars 25 mm2 and 16 mm2MINIATURE CIRCUIT BREAKERSMCB TRIPPING CURVES
95 | PROTEUS CONSUMERPROTEUS CONSUMERTECHNICAL INFORMATIONSWITCHGEAR DERATINGAdjacent MCBs, RCBOs or MCB/RCD combinations should not be continuously loaded at, or approaching, their normal rated currents when mounted in enclosures. It is also good engineering practice to make provisions for adequate free air between devices.Under these circumstances and, in common with other manufacturers, we recommend a diversity factor of 66% is applied to the MCB nominal rated current, especially if the MCB is expected to be loaded near to or at full rating for more than one hour.Thermal issues should also be taken into consideration when choosing conductor size for the protected circuits.MCB INSTALLATION CURRENTSGenerally the MCBs detailed are not intended to provide close overload protection for motors. However they can be employed in conjunction with the customary motor overload current device as an alternative to the isolator/fuse combination. In this condition the MCB will protect the cable to the motor and the motor will be protected by its own protective device.The tables A and B detailed below give recommendations on MCB selection for motor circuits, for C Curve only.Note: The values of full load current and starting current will approximately be 10% higher at 380/220V ac than the figures stated for 400/230V motors. The figures given in table A for the starting current and its duration are intended to be used as a guide only. In practice the motor run up time will depend upon the type of drive and the loading of the motor when it is started. Consultation with the motor manufacturer should give an indication of the magnitude of the starting current and the duration.The selection of the most suitable circuit breaker can then be found from the time/current characteristics of the circuit breaker.Table A: Recommended MCB current ratings for the protection of cables to single phase 230V a.c. motors.Maximum Earth fault loop impedance (ie Zs ohms) for circuits supplying socket outlets in accordance with BS7671 regulation 411.3.2 at @ 218.5V (230V x 0.95 Cmin)BS7671: 2018 requirements: Electrical installations (18th Edition of the IEE Wiring regulations) specifically identifies B and C Curve. Lower earth fault loop impedance’s (Zs) are generally necessary for D Curve to achieve the operating times required by regulation 411-3-2. Where the requirement can not be achieved, use of the circuit breakers as overcurrent protective devices is not precluded, but the use of residual current circuit breakers (RCDs) to provide protection against indirect earth fault condition is implied. Establishment of the value of the earth fault loop impedance (Zs) at the design stage of installation will determine which type of circuit breaker should be used.Technical InformationHORSE POWER (HP) POWER FLC STARTING CURRENT DURATION OF STARTING CURRENT MCB CURRENT RATING0.25 0.18 kW 1.5 A 10.5 A 3.0 sec 10 A0.50 0.37 kW 3.0 A 21.0 A 3.0 sec 10 A0.75 0.55 kW 5.0 A 35.0 A 3.0 sec 16 A1.00 0.75 kW 5.5 A 38.5 A 3.1 sec 20 A1.50 1.12 kW 8.5 A 59.5 A 3.15 sec 32 A2.00 1.50 kW 10.5 A 73.5 A 3.2 sec 50 A3.00 2.25 kW 15.5 A 108.0 A 3.3 sec 50 A4.00 3.00 kW 20.0 A 140.0 A 3.4 sec 63 A5.00 3.80 kW 24.0 A 168.0 A 3.5 sec -6.00 4.50 kW 28.0 A 196.0 A 3.6 sec -7.00 5.20 kW 32.0 A 224.0 A 3.7 sec -At these levels of earth loop impedance, MCBs will provide disconnection times in accordance with BS7671 for circuits supplying socket outlets .DEVICE STANDARD 6A 10A 16A 20A 32A 40A 50A 63A 80A 100A 125AB Curve BSEN 60898 7.43 4.46 2.79 2.23 1.39 1.11 0.89 0.71 - - -C Curve BSEN 60898 3.83 2.30 1.44 1.15 0.72 0.58 0.46 0.37 0.30 0.24 0.19D Curve BSEN 60898 1.87 1.12 0.70 0.56 0.35 0.28 0.22 0.18 - - -
96PROTEUS CONSUMER | TECHNICAL INFORMATIONTable B: Recommended MCB current ratings for the protection of cables to three phase 400V a.c. motors.Providing both overcurrent protection and earth leakage protection in a combined unit, Proteus offers a range of RCBOs which will fit all Proteus modular consumer units and B Curve 3-phase distribution boards.RCBOs are available in a range of current ratings from 6A to 45A and with short circuit capacities (Ics) from 4.5kA up to 10kA. RCBOs are offered in both B and C Curve tripping characteristics.All single module RCBOs contain a switched live and solid neutral where as the double module unit offers both Live and Neutral switching.GENERAL SPECIFICATIONSimilar to our MCB technology all devices have a ‘trip free mechanism’ and positive contact status indication. Connection of load circuit cables is via tunnel design cable clamps with touch proof and captive terminal screws. Lockable in both ON and OFF position without affecting the ability of the trip mechanism to operate.RCBOs allow earth fault protection to be restricted to individual circuits, thus ensuring that only the circuit with the fault is interrupted. (When groups of circuits are protected by an RCD, all circuits would be interrupted under a fault condition, which may cause unnecessary inconvenience).Technical InformationHORSE POWER (HP)POWER FLC STARTING CURRENTDURATION OF STARTING CURRENTMCB CURRENT RATINGSTARTING CURRENTDURATION OF STARTING CURRENTMCB CURRENT RATING0.25 0.18 0.5 3.5 3.0 6 1.75 9.0 60.50 0.37 0.9 6.3 3.0 6 3.15 9.1 60.75 0.55 1.3 9.1 3.0 6 4.59 9.2 61.00 0.75 1.9 13.3 3.1 6 6.6 9.3 61.50 1.12 2.5 17.5 3.15 10 8.7 9.5 102.00 1.50 3.4 23.8 3.2 10 11.9 9.6 103.00 2.25 4.8 33.6 3.3 16 16.8 10.0 164.00 3.00 6.4 44.8 3.4 20 22.4 10.3 205.00 3.80 7.8 54.6 3.5 20 27.3 10.7 206.00 4.50 9.0 63.0 3.6 20 31.5 11.0 207.00 5.20 10.3 72.1 3.7 32 36.0 11.3 207.50 5.60 11.6 81.2 3.75 32 40.6 11.5 3210.00 7.50 14.4 100.8 4.0 40 50.4 12.3 4012.50 9.30 17.3 121.1 4.25 40 60.5 13.2 4015.00 11.00 21.1 148.0 4.5 63 73.8 14.0 5020.00 15.00 28.0 196.0 5.0 63 93.0 15.7 6325.00 18.50 35.0 245.0 5.5 - 122.0 17.3 -7.00 5.20 32.0 224.0 3.7 -RCBOs STANDARDS: BSEN 61009OPERATING VOLTAGE: 230V a.c.EARTH LEAKAGE SENSITIVITY: 30 mASWITCHING: Single pole - L (switched) + N (solid) Double pole - L + N (switched)OPERATING FREQUENCY: 50Hz AMBIENT OPERATING TEMP.: -5°C - +40°CMAXI. TERMINAL TORQUE: 2NmENCLOSURE MATERIAL: VO rated PBT (both self extinguishing at 960°C)SUPPLY CONNECTIONS: Consult specific product data sheetIP RATING: IP4X (front face); IP20 (terminals)DIELECTRIC VOLTAGE: 2500V a.c.INSULATION VOLTAGE: 500V a.c.
97 | PROTEUS CONSUMERPROTEUS CONSUMERType 1 SPDs are key to providing necessary protection of the installation against the effects of lightning strikes entering the building. Type 1 SPDs are designed to carry partial lightning currents and are defined as being tested with a high energy 10/350μs (Iimp) wave shape.These Type 1 SPDs must be installed on incoming services (e.g. mains power and data) when an external Lightning Protection System (LPS) is installed on a building. Where partial lightning currents can also flow due to a direct lightning strike on overhead supplies or externally mounted equipment, Type 1 SPDs should also be used. Combined Type 1 + Type 2 SPDs are installed at the origin of the supply to the building, normally within the main switchboard. If the installation being protected is already fitted with an SCPD of 250 A or less then the SPD can be connected direct to the busbar otherwise ensure the device is adequately protected.Type 2 SPDs in this modular form offer more general surge protection for equipment within the installation from sources of problematic electrical surges internal to the building (typically switching transients). If the installation being protected is already fitted with an SCPD of 250 A or less then the SPD can be connected direct to the busbar otherwise ensure the device is adequately protected. Their protection is limited by distance with a general protection zone of <10m. Equipment further away necessitate the installation of an additional Type 2 units in sub-distribution boards.Type 2 and Type 3 SPDs are designed to discharge the induced surges created by lightning electromagnetic fields and also other transient surge events such as switching surges, supply faults etc. These devices are defined as being tested with a specific energy wave shape of 8/20μs (In) for Type 2 SPDs or a combination wave shapes for Type 3 SPDs. For many applications where the requirement is to provide surge protection only, Type 2 and Type 3 SPDs play a critical role in protecting electronic equipment.Type 3 SPDs provide the primary ‘fine protection’ from surges, giving high sensitive equipment that added level of security. As a rule they should be installed as close as possible to the equipment being protected.TECHNICAL INFORMATIONGENERAL SPECIFICATIONRCDs Proteus RCDs are available in a wide range of earth leakage sensitivities and current ratings to meet the majority of applications. Residual Current Devices (RCDs) come in both 2 pole and 4 pole options.Proteus RCDs incorporate the latest in electronic earth leakage detection technology ensuring consistent reliable performance. With sufficient contact gap, switching of all Live and Neutral conductors and positive contact indication in accordance with the IEE wiring regulation these devices can be used for isolation purposes.RCDs also incorporate ‘trip free mechanism’ technology and can be locked ON or OFF with suitable locking device (eg.DLPX1) without affecting the devices ability to offer protection under fault conditions.General use RCDs for domestic single phase or light commercial three phase systems are required to be either Type AC or Type A. This type reference defines the nature of the earth leakage which the RCD is expected to detect and protect against.Type AC: Tripping is ensured for residual sinusoidal alternating currents, whether suddenly applied or slowly rising.Identified by the symbol: Type A: Tripping is ensured for residual sinusoidal alternating currents and residual pulsating direct currents, whether suddenly applied or slowly rising.Identified by the symbol: SURGE PROTECTION DEVICESTechnical InformationSTANDARDS: BSEN 61008 OPERATING VOLTAGE: 2P-230V a.c. 4P-230/400V a.c.OPERATING FREQUENCY: 50HzAMBIENT OPERATING TEMP.: -5°C - +40°CMAXI. TERMINAL TORQUE: 2.5Nm ENCLOSURE MATERIAL: VO rated polyamide or PBT (both self extinguishing at 960°C)SUPPLY CONNECTIONS: Consult specific product data sheetIP RATING: IP4X (front face); IP20 (terminals)DIELECTRIC VOLTAGE: 2500V a.c.INSULATION VOLTAGE: 500V a.c.
98PROTEUS CONSUMER | TECHNICAL INFORMATIONMCCB PROTECTION OF CAPACITOR CIRCUITSMoulded case circuit breakers are not in themselves intended to afford close thermal protection on motor circuits. However, when used in tandem with any intrinsic motor overload device they provide an excellent alternative to the combined isolator and fuse arrangements. In this case the motor is protected by its own circuit breaker.In order to select the correct MCCB, consideration should be given to individual MCCB time/current characteristics (for full details please refer to works). Moulded case circuit breakers are commonly applied to capacitor currents. However, due to high in-rush currents and harmonic content found in capacitor circuits, MCCBs should be rated > 1.5 times the current rating of the capacitor.This should only be undertaken in conjunction with information provided by the motor manufacturer as to starting current and duration. The motor protection table shown provides a guide to MCCB selection based on the start current and duration indicated and it must always be noted that the drive and motor loading will affect the motor run up time.(i) The figures shown are based on the assumption that the motor starting conditions are:Direct On-Line =7 x full load current for 5 seconds max.It is recommended that the MCCB should be utilized as a main isolation/protection device to the capacitor bank. (i.e. occasional switching). Capacitors should be individually protected and switched by appropriately rated contactors.IEC UTILIZATION CATEGORIES FOR LOW VOLTAGE SWITCHGEARThe below table lists only categories applicable to BSEN 60974-3 - Switches, Disconnectors, Switch-disconnectors and Fuse-combination units.The letter A or B can be suffixed dependent on whether the intended application requires frequent (A) or infrequent (B) operation. [For full details consult the full chart in BSEN 60947-1]Technical InformationCURRENT CATEGORY TYPICAL APPLICATIONAC AC - 20 Connecting and disconnecting under no-load conditionsAC - 21 Switching of resistive loads including moderate overloadsAC - 22 Switching of mixed resistive and inductive loads, including moderate overloadsAC - 23 Switching of motor loads or other highly inductive loadsDC DC - 20 Connecting and disconnecting under no-load conditionsDC - 21 Switching of resistive loads including moderate overloadsDC - 22 Switching of mixed resistive and inductive loads, including moderate overloadsDC - 23 Switching of motor loads or other highly inductive loadsMOULDED CASE CIRCUIT BREAKERS MCCB PROTECTION OF MOTOR CIRCUITSMOTOR RATING (kW) MOTOR RATING (HP) APPROX. FLC (A) AT 400V DIRECT ON LINE MCCB TYPE/CURRENT RATING< 5.5 < 7.5 < 11.5 16 A MC016T< 11 < 15 < 22.5 25 A MC025T< 15 < 20 < 30 32 A MC032T< 18 < 25 < 36 40 A MC040T< 22 < 30 < 43 50 A MC050T< 30 < 40 < 58 63 A MC063TMR< 37 < 50 < 72 80 A MC080TMR< 51 < 70 < 98 100 A MC100TMR< 63 < 85 < 117 125 A MC125TMR< 80 < 110 < 147 160 A MC160TMR< 90 < 125 < 169 200 A MC200TMR< 110 < 150 < 205 250 A MC250TMR< 160 < 220 < 292 315 A MC315T< 200 < 270 < 368 400 A MC400T< 250 < 340 < 465 500 A MC500T< 315 < 430 < 580 630 A MC630T
99 | PROTEUS CONSUMERPROTEUS CONSUMERINGRESS PROTECTION (IP RATING)IEC/EN 60529 is an international set of test specification standards for classifying the degrees of protection provided by the enclosures of electrical equipment against the intrusion into the equipment of foreign bodies (i.e. tools, dust, fingers, etc) and moisture. This classification system utilizes the letters “IP” (“Ingress Protection”) followed by two or three digits. (A third digit is sometimes used. An “x” is used for one of the digits if there is only one class of protection; i.e. IPX4 which addresses moisture resistance only.)APPLICABLE STANDARDSThough not exhaustive the below table lists the British / European harmonised standards to which products in this catalogue comply (where applicable).The first digit of the IP code indicates the degree that persons are protected against contact with moving parts (other than smooth rotating shafts, etc.) and the degree that equipment is protected against solid foreign bodies intruding into an enclosure.The second digit indicates the degree of protection of the equipment inside the enclosure against the harmful entry of various forms of moisture (e.g. dripping, spraying, submersion, etc.)[For full details consult IEC/EN60529]TECHNICAL INFORMATIONTechnical Information1ST DIGIT PROTECTION FROM SOLID OBJECTS 2ND DIGIT PROTECTION FROM MOISTURE1 Protected against solid object greater than 50 mm 1 Protection against vertically dripping water2 Protected against solid object greater than 12.5 mm 2 Protection against dripping water when tilted upto 15degrees3 Protected against solid object greater than 2.5 mm 3 Protection against spraying water4 Protected against solid object greater than 1 mm 4 Protection against splashing water5 Dust protected 5 Protection against jetting water6 Dust tight 6 Protection against powerfully jetting water7 Protection against the temporary affects of immersion8 Protection against continuous submersionSTANDARD TITLEBS88 Cartridge fuses for voltages up to and including 1000A a.c. and 1500V d.c.BS EN 60269 Low-voltage FusesBS EN 61439 Low-voltage switchgear and controlgear assembliesBS EN 61439-2 Power switchgear and controlgear assembliesBS EN 61439-3 Distribution boards intended to be operated by ordinary persons (DBO)BS EN 60529 Specification for degree of protection provided by enclosures (IP code)BS EN 60898 Specification for circuit-breakers for overcurrent protection for household and similar installationsBS EN 60947 Low-voltage switchgear and control gearBS EN 60947-2 Circuit-breakersBS EN 60947-3 Switches, disconnectors, switch-disconnectors and fuse-combination unitsBS EN 60947-4 Electromechanical contactors and motor startersBS EN 61008 Residual current operated circuit breakers without integral overcurrent protection for household and similar use (RCCBs / RCDs)BS EN 61009 Residual current operated circuit breakers with integral overcurrent protection for household and similar use (RCBOs)BS EN 61095 Specification for electromechanical contactors for household and similar purposesIEC/EN 61643-11 Surge Protection DevicesBS EN 62606 Arc Fault Detection Devices
The content of this catalogue is for information only. The manufacturer reserves the right to alter design or specification without prior notice.Colours are reproduced as accurately as photographic and printing processes allow and may not exactly match the actual products.Proteus Industrial01952 292 001ind@proteusswitchgear.co.ukwww.proteusswitchgear.co.ukStafford Park 12TelfordShropshireTF3 3BJProteus Consumer01527 517 117cons@proteusswitchgear.co.ukwww.proteusswitchgear.co.ukPipers Road, Park Farm Ind. Est. RedditchWorcestershireB98 0HU Proteus Switchgear @proteusswitchgPROTEUS SWITCHGEAR