Return to flip book view

McElroy Metal Roof and Wall Systems

Page 1

ME T A L ROOF W A L L S Y S T E M S 2019 C A T A L OG

Page 2

Table Of Contents Thomas E McElroy Sr Mr Mac in 1963 posing with the company s first rollformer From humble beginnings in 1963 McElroy Metal has grown into a national company with 13 manufacturing and 24 Service Center locations across the United States McElroy Metal is a third generation family owned business with a strong culture of values that extends to customers employees and vendors Contents McElroy Information Soffit Fascia Canopy R Panel Roof Wall 25 Resources inside front cover FW Series Soffit 16 Multi Rib Roof Wall 25 MCP Canopy 16 Mini Rib Wall Fascia Liner 25 Matrix Soffit 17 Multi V Wall 25 Marquee Lok Soffit Fascia Wall 17 Specialty Panels Marquee II Soffit Fascia Wall 17 Met Tile 27 Location Map 1 Standing Seam Systems Maxima Roof 2 3 Milan 27 138T 238T Panel Roof 4 5 Concealed Fastener Panels 138T 238T Recover Roof 7 Wave Wall 19 Medallion Lok Roof 9 MSR Wall 19 Meridian Roof 11 Retrofit Roofing Systems 29 Solar Solutions 31 Instaloc Roof 11 Exposed Fastener Medallion I Roof 13 Mega Rib Roof Wall 21 Medallion II Roof 13 Multi Cor M Cor Roof Wall 21 Mirage Roof 14 Max Rib Roof Wall 23 Mirage II Roof 14 Mesa Roof Wall 23 MasterLok 90 Roof 15 5V Roof Wall 23 MasterLok FS Roof 15 U Panel Roof Wall 23 For the most current information please visit our website at www mcelroymetal com Green Span Profiles Insulated Metal Panels inside back cover Slit Coil and Flat Sheets back cover

Page 3

Page 4

Standing Seam Systems Maxima 1 5 12 Maxima 1 5 16 18 Maxima 2 12 Maxima 2 16 18 Maxima ADV 2 12 Maxima ADV 2 16 18 Maxima 3 Minor Rib Std 18 24 18 panel only available with one minor rib 2 SEAM 90 DE GR EE SE 18 AM 0D EG RE ES EA M NO NE FACTORY NOTCHING EA VE MAXIMA PROFILES PAN CONDITIONS W IDT HI NI NC HE ST RIA S TE D MI NO RR IBS SIN GL EP EN CIL DO RIB UB LE PE NC FLA IL R TP IB AN CU RV ED LA P WIDTH Curving Details Only Maxima 1 5 and Maxima ADV can be curved Minimum radius 25 for 2 ADV 12 for 1 5 180 seam required Sealant to be field applied on curved applications Maxima ADV and Maxima 1 5 flat panels will curve naturally on a radius of 250 feet or greater Striated panels are recommended as they reduce the appearance of oil canning

Page 5

Maxima Offering strength durability and aesthetics vertical leg standing seam Maxima 1 5 systems are the industry s most popular roofing panel To meet the varying 1 5 needs of specifiers and contractors McElroy Metal s Maxima line represents the industry s broadest selection of vertical leg systems Maxima 2 12 16 or 18 Striated Seam heights of 1 5 2 3 2 Varying pan widths 90 180 seams 12 16 or 18 Striated Available flat or curved Maxima ADV 2 12 16 or 18 Striated Note Maxima ADV also available without shoulders Maxima 3 3 18 18 Minor Rib 3 24 24 Minor Ribs Note Maxima 2 and 3 panels feature a return leg on both the male and female seams These return legs help create greater strength and uplift capabilities Maxima 1 5 and ADV do not feature the return legs which enables the panels to be curved as well as seamed to 180 degrees 2 16 Low Floating Clip Maxima Before Seaming Maxima 90 Fold Maxima ADV Maxima 1 5 180 Fold Factory Formed Eave Notch Eave Notch Folded In Field Note Patented Floating Clips allow for 3 1 8 of thermal movement Details Panel Options Testing Data Mechanically seamed profile Fire Rating Class A Factory formed eave notch upon request Panel height width See panel profile drawings above Factory applied sealant on non curved panels only Panel configurations See chart on left Minimum slope 1 12 for 1 5 Coating Kynar 500 PVDF Minimum slope 1 2 12 for 2 Substrate Standard 24 gauge Galvalume Optional 22 gauge Galvalume 032 and 040 aluminum Aluminum is produced at the Sunnyvale TX facility only No testing available on aluminium Minimum slope 1 4 12 for 3 Can be installed over solid deck or open framing Maxima 2 and ADV also available jobsite formed for long lengths Uplift Test UL580 Class 90 FM 4471 for 2 only 1 90 Rated ASTM E1592 for 1 5 2 3 Air Infiltration ASTM E1680 Water Infiltration ASTM E1646 Class 4 Impact Resistance UL 2218 Florida State Approval 1747 3 2 3 1832 4 2 3 Fire Resistance UL 263 Miami Dade Approval 216 only NOA 17 0320 04 ICC ES Approval ESL 1082 All testing conducted with Galvalume substrate For any available Test Data Section Properties or Load Tables please visit our download section at www mcelroymetal com Floating clips allow for 3 1 8 thermal movement Oil canning pan wave is a natural occurrence in metal panels and is not a cause for panel rejection 3

Page 6

Standing Seam Systems Jobsite Production Vehicles Available for Maxima 2 Maxima ADV 138T 238T 138T 238T 138T 238T symmetrical standing seam systems offer many advantages over popular asymmetrical panels 138T and 238T panels do not have male and female seams Rather these panels have identical left and right seams Panels are then joined with a mechanically seamed cap Ease of installation Factory Applied Sealant Available flat curved and tapered Individual panel replacement Watertight seam design Can be jobsite formed for longer lengths No laps equals greater watertightness 4 Seam Engagement Before Seaming After Seaming

Page 7

138T 238T Panel 138T Panel Options 238T Panel Options 1 375 138T Clip 2 375 16 or 18 Plank Pencil Ribs 16 18 or 24 Plank Pencil Ribs 238T Clip 1 375 2 375 12 16 or 18 Plank 16 18 24 Plank 1 375 12 16 or 18 Striated 2 375 16 18 or 24 Striated 1 375 12 16 or 18 Minor Rib 138T and 238T Two Piece Multi Span Clip 238T Shown 2 375 1 375 16 18 or 24 Minor Rib 12 16 or 18 Flat 2 375 138T and 238T Two Piece Multi Span Clip as Installed 238T Shown 16 18 or 24 Flat 138T Details Testing Data 238T Details Testing Data Mechanically seamed Fire Rating UL Class A Mechanically seamed Fire Rating UL Class A Minimum slope 2 12 Uplift Test UL580 Class 90 UL 1897 ASTM E1592 Minimum slope 1 2 12 Uplift Test UL580 Class 90 UL 1897 FM 4471 ASTM E1592 Must be installed over solid deck Panel Options 138T panel width 12 16 18 Panel configurations 138T 16 18 flat striated plank pencil ribs plank minor ribs plank pencil rib recommended 138T 12 flat striated minor ribs plank plank recommended Coating Kynar 500 PVDF Substrate Standard 24 gauge Galvalume Optional 22 gauge Galvalume 032 and 040 aluminum Optional 16 oz and 20 oz copper Houston plant only 138T manufacturing factory jobsite roll formed curved on site Impact Resistance UL Class 4 For any available Test Data Section Properties or Load Tables please visit our download section at www mcelroymetal com 238T subject to prior approval 1 4 12 may be acceptable Can be installed over solid deck or open framing Panel Options 238T panel width 16 18 24 24 panel formed on site only Air Water Infiltration ASTM E1680 ASTM E1646 Impact Resistance UL Class 4 Static Water FM 4471 Appendix G ASTM E2140 Texas Department of Insurance Approval RC 270 238T only Panel configurations 238T flat 16 18 only striated plank pencil ribs plank minor ribs plank pencil ribs recommended Florida State Approval 16606 1 16606 2 16606 3 Coating Kynar 500 PVDF ICC ES Approval ESL 1082 Substrate Standard 24 gauge Galvalume Optional 22 gauge Galvalume 032 and 040 aluminum Optional 16 oz and 20 oz copper Houston plant only FM Class 1 SH Miami Dade Approval NOA 15 1216 03 For any available Test Data Section Properties or Load Tables please visit our download section at www mcelroymetal com 238T manufacturing factory jobsite roll formed curved on site Oil canning pan wave is a natural occurrence in metal panels and is not a cause for panel rejection 5

Page 8

Standing Seam Recover Systems 46

Page 9

138T Shingle Recover System 238T Metal Over Metal System Featuring McElroy s 138T symmetrical standing seam McElroy Metal s patented 238T frameless metal over metal recover panel this innovative system installs directly over solutions provide low cost retrofit solutions over both existing existing shingles without tear off or underlayment exposed fastened and 3 tall trapezoidal standing seam systems Ease of installation Above sheathing ventilation ASV Utilizing air space to help reduce heat transfer and decrease energy expense No tear off disposal of existing roof No underlayment required Two patented frameless recover systems Job site production enables eave to ridge panels Extremely high wind uplift capacity without additional edge zone or corner framing 24 wide panels reduce installation labor Individual panel removal and replacement Decades long service life Individual panel replaceability Decades long service life Seaming Seam Engagement Before Seaming After Seaming 4 ASV clip 8 shingle recover clip with ASV Note 4 ASV clip for new construction or remove and replace Die cut foam insulation is placed over the exiting roof panels and the 238T panels are placed on top of the insulation The 238T panels are then joined together using 238T caps and a mechanical seamer Corrugated sheeting installed at the ridge allows for continuous air flow between the existing and new roof while providing support for the panel and closure Free flowing air space between a metal roof and shingles can reduce heat transfer The key to a proper installation of a standing seam recover over shingles is the patented Single length panels offer labor savings and improve weathertightness shingle recover clip which is long enough to sit on two shingles simultaneously 7

Page 10

Standing Seam Systems 8

Page 11

Medallion Lok Medallion Lok is a snap together architectural panel with structural Panel Options capabilities that features a rigid 1 75 standing seam Medallion Lok 0 375 is McElroy Metal s most popular snap together panel and has been 1 75 utilized to add beauty and function on projects all across the country 12 16 12 16 18 Striated 0 375 1 75 12 16 12 16 18 Flat 0 375 1 75 16 18 16 Double Pencil Ribs 0 375 1 75 12 Single Pencil Rib Note Striated panels are recommended as they reduce the appearance of oil canning Standard Clip UL 90 Clip Seam Detail Factory Eave Notch Details Panel Options Testing Data Factory formed eave notch upon request in Clinton Peachtree City and Sunnyvale Panel width 12 16 18 Fire Rating Class A Factory applied sealant Minimum slope 3 12 Can be installed over solid deck or open framing Panel configurations striated ribbed or flat pan striated recommended Coating Kynar 500 PVDF Substrate Standard 24 gauge Galvalume Optional 22 gauge Galvalume 032 and 040 aluminum Uplift Test UL580 Class 90 ASTM E1592 Air Infiltration ASTM E1680 Water Infiltration ASTM E1646 Class 4 Impact Resistance UL 2218 Oil canning pan wave is a natural occurrence in metal panels and is not a cause for panel rejection Eave Notch Folded In Field Florida State Approval 1747 5 and 1832 7 Fire Resistance UL 263 Miami Dade Approval NOA 13 0430 06 ICC ES Approval ESL 1082 For any available Test Data Section Properties or Load Tables please visit our download section at www mcelroymetal com 9

Page 12

Standing Seam Systems 10

Page 13

Meridian Instaloc Meridian is an economical snap together roofing system that is Instaloc is a snap together standing seam that features a an excellent choice for commercial and residential applications 1 seam and is installed with concealed clips Instaloc is Panels are simply installed by placing pancake head fasteners in an excellent selection for applications where greater uplift the panel s slotted flange Meridian is installed over solid deck characteristics are required than achieved with Meridian 12 Cover Width 1 91 13 Plank Minor Rib 16 Cover Width 1 91 13 Striated Minor Ribs 16 Cover Width 1 91 13 Minor Ribs Striated Meridian manufactured in Clinton IL features a slightly different lap and should not be mixed with panels from other facilities Seam Detail Factory Eave Notch Eave Notch Folded In Field Instaloc Clip Seam Detail Details Testing Data Details Testing Data Factory formed eave notch upon request Fire Rating Class A Minimum Slope 3 12 Fire Rating Class A Air Infiltration ASTM E1680 Minimum slope 3 12 Water Infiltration ASTM E1646 Must be installed over solid deck Uplift Test UL580 Class 90 UL 1897 Factory applied sealant Class 4 Impact Resistance UL 2218 Must be installed over solid deck Panel Options Panel width 12 and 16 Panel configurations 16 minor ribs or striated 12 minor ribs or striated Coating Kynar 500 PVDF Substrate Standard 26 gauge Galvalume for 16 panels only Standard 24 gauge Galvalume for 12 and 16 panels Class 4 Impact Resistance UL 2218 Instaloc is produced in Houston TX Texas Department of Insurance Approval Evaluation RC 34 Panel Options Florida State Approval 2358 1 Panel width 13 For any available Test Data Section Properties or Load Tables please visit our download section at www mcelroymetal com Panel configurations striated plank and minor rib striated recommended Texas Department of Insurance Approval RC 86 Coating Kynar 500 PVDF Substrate Standard 24 gauge Galvalume Oil canning pan wave is a natural occurrence in metal panels and is not a cause for panel rejection 11

Page 14

Standing Seam Systems 12

Page 15

Medallion I Medallion II Medallion I is an architectural standing seam system Medallion II is an architectural standing seam system that featuring a narrow batten cap applied over roofing panels features a 1 1 2 wide batten cap applied over roofing and concealed clips Medallion I is installed over solid deck panels and concealed clips Medallion II is installed over and can also be curved to meet radius panel specifications solid deck 6875 6875 12 16 or 18 Striated 12 16 or 18 Striated Cover width is pan width plus 1 Medallion I Batten Medallion I Clip Medallion II Batten Medallion II Clip Details Testing Data Details Testing Data Minimum slope 3 12 Fire Rating Class A Minimum slope 3 12 Fire Rating Class A Must be installed over solid deck Uplift Test UL580 Class 90 Must be installed over solid deck Uplift Test UL580 Class 90 Curving Details Water Infiltration ASTM E1646 Panel Options Water Infiltration ASTM E1646 Minimum radius 30 Panel Options Panel width 12 16 and 18 Panel configurations striated recommended ribbed or flat pan Coating Kynar 500 PVDF Substrate Standard 24 gauge Galvalume Air Infiltration ASTM E1680 Class 4 Impact Resistance UL 2218 Florida State Approval 1832 5 Fire Resistance UL 263 For any available Test Data Section Properties or Load Tables please visit our download section at www mcelroymetal com Panel width 12 16 and 18 Panel configurations striated recommended ribbed or flat pan Coating Kynar 500 PVDF Substrate Standard 24 gauge Galvalume Oil canning pan wave is a natural occurrence in metal panels and is not a cause for panel rejection Air Infiltration ASTM E1680 Class 4 Impact Resistance UL 2218 Florida State Approval 1832 6 Fire Resistance UL263 For any available Test Data Section Properties or Load Tables please visit our download section at www mcelroymetal com 13

Page 16

Mirage Mirage II Mirage is a concealed fastener roofing panel with 1 5 8 Mirage II is a concealed fastener roofing panel with 1 3 4 high ribs spaced 8 on center Mirage can be installed high ribs spaced 8 on center Mirage II can be installed over solid deck or substructural members over solid deck or substructural members 8 8 8 1 625 8 1 75 16 Cover Width Mirage Clip Mirage Details 16 Cover Width Mirage II Clip Seam Detail Seam Detail Testing Data Mirage II Details Testing Data Minimum slope 1 4 12 Fire Rating Class A Minimum slope 1 4 12 Fire Rating UL790 Class A Factory applied sealant is required on slopes less than 3 12 Uplift Test UL580 Class 90 ASTM E1592 Factory applied sealant is required on slopes less than 3 12 Uplift Test UL580 Class 90 Can be installed over solid deck or open framing Air Infiltration ASTM E1680 Can be installed over solid deck or open framing Mirage is also available with Moisture Lok Water Infiltration ASTM E1646 Mirage II is produced in Bossier City LA and Ashburn GA Mirage is produced in Adelanto CA Class 4 Impact Resistance UL 2218 Panel Options Panel Options Florida State Approval 1747 7 1832 9 Panel configurations ribbed Panel width 16 Panel configurations ribbed Coating Kynar 500 PVDF Substrate Standard 24 gauge Galvalume 14 Impact UL2218 Class 4 Panel width 16 IAPMO Approval ER 0270 Coating Kynar 500 PVDF Fire Resistance UL263 Substrate Standard 24 gauge Galvalume For any available Test Data Section Properties or Load Tables please visit our download section at www mcelroymetal com Oil canning pan wave is a natural occurrence in metal panels and is not a cause for panel rejection

Page 17

MasterLok 90 MasterLok FS MasterLok 90 is a snap together trapezoidal standing seam MasterLok FS is a mechanically seamed trapezoidal standing system designed for projects with slopes as low as 1 12 seam system designed for projects with slopes as low as 1 4 12 MasterLok 90 is best suited for simple sloped roofs without MasterLok FS is best suited for simple sloped roofs without dormers hips valleys or other special conditions MasterLok 90 dormers hips valleys or other special conditions and can be is installed over solid deck or substructural members installed over solid deck or substructural members 3 3 24 Cover Width ML 90 Low Floating Clip Seam Detail 24 Cover Width ML FS Low Floating Clip Other utility fixed and floating clips available MasterLok 90 Details Factory applied sealant in seam to improve weather tightness Minimum slope 1 4 12 Can be installed over solid deck or open framing Panel Options Panel width 24 Coating Kynar 500 PVDF Substrate Standard 24 gauge Galvalume Optional 22 gauge Galvalume Also available with Moisture Lok Before Seaming After Seaming Other floating clips available Testing Data MasterLok FS Details Testing Data Fire Rating Class A Mechanically seamed profile Fire Rating Class A Uplift Test UL580 Class 90 ASTM E1592 Factory applied sealant in seam to improve weather tightness Uplift Test UL580 Class 90 ASTM E1592 Air Infiltration ASTM E1680 Can be installed over solid deck or open framing Water Infiltration ASTM E1646 Minimum slope 1 4 12 Air Infiltration ASTM E1680 Water Infiltration ASTM E1646 Class 4 Impact Resistance UL 2218 Panel Options Panel width 24 Class 4 Impact Resistance UL 2218 Florida State Approval 1832 2 1747 1 Coating Kynar 500 PVDF Florida State Approval 8051 1 Substrate Standard 24 gauge Galvalume Optional 22 gauge Galvalume For any available Test Data Section Properties or Load Tables please visit our download section at www mcelroymetal com For any available Test Data Section Properties or Load Tables please visit our download section at www mcelroymetal com Oil canning pan wave is a natural occurrence in metal panels and is not a cause for panel rejection 15

Page 18

Soffit Fascia Canopy Panel FW Panel McElroy Metal s FW Panel features a 1 5 deep flush metal panel designed for usage in vertical applications Available options include deep vee grooves reveal 1 2 up to 3 in 1 2 increments or a Reveal Options Flush Panel Interlock Typical 1 Reveal For 12 Panels Custom Reveal For 12 Panels up to 3 traditional smooth appearance Regardless of the pattern the 1 5 depth and the tongue and groove engagement remain the same Inverted Plank Profile 1 5 12 MCP Flat 1 5 MCP McElroy Canopy Panel is a concealed fastener panel designed to meet the demands of canopy installations 12 Vee Grooves Banks drive thru restaurants convenience stores or any other building type requiring attractive and functional 1 5 canopy systems are an excellent application for MCP 12 Details Maximum lengths 24 gauge 2 minimum and 8 maximum 22 gauge 2 minimum and 15 maximum FW is produced in Houston TX Reveal Options 1 to 3 panel remains at 12 and reveal size increases coverage 3 12 and 16 Canopy Panel Coating Kynar 500 PVDF Substrate Standard 24 gauge Galvalume Optional 22 gauge Galvalume MCP Clip Panel Options Panel width 12 Testing Data Panel configurations inverted plank flat vee grooves Uplift Test ASTM E1592 16 FW Reveal No testing Oil canning pan wave is a natural occurrence in metal panels and is not a cause for panel rejection

Page 19

Matrix 12 and Matrix 16 Marquee Lok and Marquee II Matrix soffit systems will add an elegant touch to any Marquee Lok and Marquee II are soffit and fascia panels that commercial or residential project Matrix panels are easy are coated in colors matching McElroy s standing seam systems to install And to minimize on site labor McElroy Metal The end result is assurance of an exact color match between roof inventories 11 5 and 23 5 length panels system soffit fascia and wall panels McElroy Metal s Marquee Lok panel features a unique locking design that adds strength and helps to prevent the panels from 375 unlatching due to high suction force during a wind incident No 12 other panel in the industry features this type of locking mechanism 375 16 936 12 12 Panels Details 16 Panels Matrix 16 Acrylic Coated Galvalume 26 gauge and 29 gauge Kynar 500 PVDF 26 gauge Siliconized Polyester 29 gauge Details Panel Options Marquee Lok 8 net free area with vented surface Marquee II 2 net free area with vented surface Panel width 12 Matrix 12 is produced in Lewisport KY Substrate Standard Matrix 12 24 gauge and 29 gauge Galvalume Matrix 16 is produced in Marshall MI Maximum lengths 24 GA and 032 aluminum is 8 22 GA is 15 Standard Matrix 16 26 gauge and 29 gauge Galvalume Panel Options Marquee Lok is produced in Clinton IL and Peachtree City GA Testing Data Stocked lengths 11 5 and 23 5 10 net free area with vented surface Panel width 12 and 16 Panel configurations non vented or vented Coating Matrix 12 Acrylic Coated Galvalume 24 gauge and 29 gauge Kynar 500 PVDF 24 gauge and 29 gauge Uplift Test ASTM E1592 For any available Test Data Section Properties or Load Tables please visit our download section at www mcelroymetal com Marquee II is produced in Adelanto CA Marquee Lok panel configurations Non vented flat or double pencil ribs on center spacing with double pencil ribs is 4 Vented flat or single pencil rib Marquee II panel configurations Non vented flat single rib or double pencil ribs Vented flat or single pencil rib vented available in 24 gauge only Coating Kynar 500 PVDF Testing Data Uplift Test ASTM E1592 Marquee Lok with locking feature only Substrate Standard 22 gauge Galvalume Optional 24 gauge Galvalume For any available Test Data Section Properties or Load Tables please visit our download section at www mcelroymetal com Oil canning pan wave is a natural occurrence in metal panels and is not a cause for panel rejection 17

Page 20

Concealed Fastener Wall Panel Pre Notched Wave Flashing Wave pre notched transition flashings allow for thermal expansion and contraction while providing an attractive finishing detail Also available Wave s pre notched corner flashing 18

Page 21

Wave MSR Available in both fixed and floating systems McElroy Metal s MSR is a concealed fastener wall panel by McElroy Metal Wave panels are concealed fastener wall panels that can that combines aesthetics and strength in one panel be installed vertically or horizontally over solid substrate or MSR s bold profile will add curb appeal to most any project subframing Wave Fixed is installed with Wave s integral while providing the engineering and weather tightness fastening flange which is roll formed into the panel during the characteristics demanded by architects and owners manufacturing process and can be utilized for panel lengths of 40 or less Wave Floating panels utilize separate clips and 16 Cover Width should be specified for panel lengths of 40 or greater 3 Wave Fixed Wave Floating 1 6 5 1 6225 1 625 1 125 5 1 125 2 375 2 375 16 Coverage 16 Coverage 4 4 75 75 MSR with Clip MSR with Fablok Fastener Wave Floating Clip Details Panel Options Details Concealed fastener wall panel Panel width 16 Typically installed horizontally but can be installed vertically Coating Kynar 500 PVDF Concealed fastener wall panel for use with Fablok fasteners or angle clips Wave Fixed used for panel lengths 40 or less Substrate Standard 24 Gauge Galvalume Optional 22 gauge Galvalume Wave Fixed has a concealed fastening flange Wave Floating used for panel lengths greater than 40 Wave Floating utilizes a clip Can be installed over solid deck or open framing Substrate Standard 24 gauge Galvalume Optional 22 gauge Galvalume Also called Shadow Rib panel Testing Data MSR is produced in Sunnyvale TX Water Penetration ASTM E331 Air Infiltration ASTM E283 Acoustical Performance ASTM E90 Testing Data Panel Options Uplift Test ASTM E1592 Panel width 16 For any available Test Data Section Properties or Load Tables please visit our download section at www mcelroymetal com Panel height 3 Maximum panel length 50 For any available Test Data Section Properties or Load Tables please visit our download section at www mcelroymetal com Coating Kynar 500 PVDF Wave is produced in Houston TX Oil canning pan wave is a natural occurrence in metal panels and is not a cause for panel rejection 19

Page 22

Exposed Fastener Panels 20

Page 23

Mega Rib Multi Cor M Cor Mega Rib is a 7 2 panel that provides optimum strength McElroy s corrugated panels were designed and engineered and spanning capabilities Mega Rib is equally well suited with greater than normal spans and load carrying characteristics for industrial and commercial applications in mind And they quickly communicate their high strength performance capabilities McElroy s Multi Cor and M Cor are similar in design with M Cor offering a more subtle rib height 7 2 and configuration 1 5 36 Cover Width Multi Cor 2 67 7 2 875 1 5 32 Cover Width 28 8 Cover Width Note Mega Rib is also available with a 28 8 coverage which is standard for 26 gauge panels Please specify if 36 coverage is required M Cor 2 67 5 34 67 Cover Width Details Minimum slope 1 12 Tape sealant required on all slopes Adelanto standard coverage for 26 gauge is 36 All other locations standard 26 gauge coverage is 28 8 specify if 36 coverage is required Can be installed vertically or horizontally Panel Options Coating Kynar 500 PVDF Substrate Standard 24 gauge Galvalume Optional 22 gauge Galvalume Optional 26 gauge Galvalume narrow coverage Optional 26 gauge Galvalume full coverage Adelanto only Optional 18 and 20 gauge painted Galvalume limited availability Testing Data Fire Rating Class A Uplift Test UL580 Class 90 Air Infiltration ASTM E1680 Water Infiltration ASTM E1646 Class 4 Impact Resistance UL2218 Florida State Approval 1832 8 1747 6 Fire Resistance UL263 Miami Dade Approval NOA 15 1013 06 ICC ES Approval ESR 5896 For any available Test Data Section Properties or Load Tables please visit our download section at www mcelroymetal com Details Testing Data Multi Cor minimum slope 1 12 Fire Rating Class A M Cor minimum slope 1 12 Uplift Test UL580 Class 90 Multi Cor only Tape Sealant required on all slopes Multi Cor and M Cor can be installed over solid deck or open framing Class 4 Impact Resistance UL 2218 Florida State Approval 10680 1 Multi Cor only Multi Cor and M Cor are produced in Bossier City LA Texas Department of Insurance Approval Evaluation RC 158 Multi Cor only Panel Options For any available Test Data Section Properties or Load Tables please visit our download section at www mcelroymetal com Coating Kynar 500 PVDF Silicone Modified Polyester SMP Substrate Standard 26 gauge Galvalume Multi Cor is also available in 24 and 22 gauge Galvalume M Cor is also available in 29 and 24 gauge Galvalume Oil canning pan wave is a natural occurrence in metal panels and is not a cause for panel rejection 21

Page 24

Exposed Fastener Panels 22

Page 25

Max Rib Mesa Max Rib is a low profile 3 4 panel that is well suited for Mesa is a patent and copyright protected panel that features post frame commercial and residential applications a nearly invisible lap Designed for Post Frame and residential applications Mesa will add beauty to any project 9 9 75 75 36 Cover Width 36 Cover Width Details Details Minimum slope 1 12 with sealant Class 4 Impact Resistance UL 2218 Minimum slope 3 12 without sealant Florida State Approval 1747 2 1832 3 Minimum slope 3 12 without sealant Also available with Moisture Lok Fire Resistance UL263 Testing Data Texas Department of Insurance Approval Evaluation RC 157 Fire Rating Class A Uplift Test UL580 Class 90 For any available Test Data Section Properties or Load Tables please visit our download section at www mcelroymetal com Minimum slope 1 12 with sealant Patent and copyright protected Nearly invisible lap Ideal for post frame structures and residential roofing Also available with Moisture Lok 5V U Panel Homeowners across the country are discovering that metal U Panel is an exposed fastener wall and roof panel that roofing not only adds value to their home but provides beauty is also used extensively as a liner or partition panel as well McElroy s 5V panel incorporates a classic design that 6 47 64 will add beauty to any residential or commercial project 36 Cover Width 12 5 Note Also available U Panel with non purlin bearing leg 24 Cover Width Details Minimum slope 3 12 with sealant 5V must be installed over solid decking 5V is produced in Ashburn GA and Merkel TX Testing Data Fire Rating Class A Uplift Test UL580 Class 90 Class 4 Impact Resistance UL 2218 Details Fire Resistance UL263 Minimum slope 2 12 with sealant For any available Test Data Section Properties or Load Tables please visit our download section at www mcelroymetal com Florida State Approval 1832 1 Fire resistance UL263 Texas Department of Insurance RC 13 Miami Dade Approval NOA 13 0430 05 For any available Test Data Section Properties or Load Tables please visit our download section at www mcelroymetal com Testing Data Fire Rating Class A Uplift Test UL580 Class 90 Class 4 Impact Resistance UL 2218 Florida State Approval 8885 1 IAPMO Approval ER 0270 Oil canning pan wave is a natural occurrence in metal panels and is not a cause for panel rejection 23

Page 26

Exposed Fastener Panels 24

Page 27

R Panel Multi Rib R Panel is a multi use roof and wall panel used primarily Multi Rib is a multi use roof and wall panel used primarily in pre engineered metal building applications in pre engineered metal building applications 12 12 1 25 1 1875 36 Cover Width 36 Cover Width 12 12 1 25 1 1875 36 Cover Width Details Florida State Approval 1747 9 1832 11 Minimum slope 1 12 with sealant Fire Resistance UL263 Testing Data Fire Rating Class A Uplift Test UL580 Class 90 ASTM E1592 24 GA PBR only Air Infiltration ASTM E1680 Water Infiltration ASTM E1646 Class 4 Impact Resistance UL 2218 36 Cover Width Details Class 4 Impact Resistance UL 2218 Minimum slope 1 12 with sealant Florida State Approval 1747 8 1832 10 Miami Dade Approval NOA 17 0829 04 roof 24 gauge min PBR NOA 17 0829 05 wall 24 gauge min PBR Also available with Moisture Lok Texas Department of Insurance Approval RC 284 PBR only Uplift Test UL580 Class 90 ASTM E1592 26 PBR For any available Test Data Section Properties or Load Tables please visit our download section at www mcelroymetal com Air Infiltration ASTM E1680 Fire Resistance UL263 Texas Department of Insurance Approval Evaluation RC 63 and RC 283 Testing Data Fire Rating Class A For any available Test Data Section Properties or Load Tables please visit our download section at www mcelroymetal com Water Infiltration ASTM E1646 Mini Rib Multi V The symmetrical design of McElroy s Mini Rib panel Multi V is an exposed fastener wall panel that is designed so makes it an appealing profile for wall soffit liner that fasteners are placed in the valleys making them visually and fascia applications less apparent 3 375 12 1 1875 36 Cover Width Details Mini RIb is produced in Bossier City LA 35 75 Cover Width Testing Data For any available Test Data Section Properties or Load Tables please visit our download section at www mcelroymetal com Testing Data For any available Test Data Section Properties or Load Tables please visit our download section at www mcelroymetal com Oil canning pan wave is a natural occurrence in metal panels and is not a cause for panel rejection 25

Page 28

Met Tile Milan 26

Page 29

Met Tile Milan Met Tile roofing panels provide the appearance of ceramic Milan shingles add beauty and curb appeal to any home or tile roofing with all the advantages and performance of metal business Offering eight attractive Kynar 500 colors as well Met Tile is lightweight energy efficient and aesthetically as Slate and Shake Kynar 500 Prints McElroy Metal s Milan attractive Since Met Tile is a panelized roofing system will compliment any exterior design palette installation takes a fraction of the time required for ceramic tiles Panels are installed vertically from eave to ridge and are secured to the deck with fasteners Kynar 500 Colors Kynar 500 Colors Cotillion White Ebony Manor Gray New Penny Keystone Gray Adobe Red Linen Heritage Green Homestead Brown Gallery Blue Kynar 500 Designer Prints Coral Blue Bravo Red Morocco Red Meadow Green Mission Clay Spanish Tile Red Ranchwood Brown Slate Gray Note Colors are representative of colors offered Minimum slope 1 1 2 12 required with sealant Minimum slope 3 12 required without sealant Must be installed over solid deck Gray Slate Green Slate Red Slate Classic Cedar Shake Cedar Shake Seasoned Cedar Shake Note Colors are representative of colors offered and are not intended for matching purposes Details Blue Slate and are not intended for matching purposes Panel width 38 5 16 Details Testing Data Panel coverage 36 3 16 Minimum Slope 3 12 Florida State Approval 19173 1 Steps are 1 OC Panel exposure 39 x 12 Coating low gloss Kynar 500 PVDF Panels per square 30 77 Met Tile is produced in Sunnyvale TX Substrate 26 gauge Galvalume stucco embossed only Panel Options Testing Data Panel lengths 2 20 in 1 increments Fire Rating Class A Florida State Approval 17905 1 Continuous integrated nailing flange Four way interlock system secured to the roof using aluminum fastening clips Can be installed over most existing asphalt shingles or solid deck Oil canning pan wave is a natural occurrence in metal panels and is not a cause for panel rejection Panel Options Weight per square 76 lbs Coating Kynar 500 PVDF Designer prints in Kynar 500 PVDF also available Substrate 29 gauge G90 Galvanized steel 27

Page 30

Retrofit Systems 28

Page 31

Retrofit Systems McElroy Metal has the optimal solution for building owners architects and contractors who desire a high performance long term solution for worn out conventional roofs McElroy Metal Retrofit Roofing Systems provides an extended service life and reduced life cycle costs In many cases the cost difference between a conventional roof tear off and replacement compared to a retrofit metal roof system is a return on investment which can be recovered in a short period of time Building Owner Benefits The Contractor s Advantages Decades long service life Easy to erect framing systems Reduced maintenance Designed by in house McElroy Metal engineering staff Proven and tested standing seam metal roofing systems All materials manufactured by McElroy Metal Quicker than normal turn around times Reduces landfill expenses for disposal of existing materials Energy savings through reduced consumption Aids in LEED certification Increases wind and snow storm resistance Possible reduction of insurance premiums Improves appreciable value of your building McElroy Metal Retrofit Roofing Systems are engineered to adapt to the existing roof s structural support system whether constructed of steel concrete or wood Adaptation to Steel Adaptation to Concrete Substructural Components McElroy s substructural components Cees Zees Hats Channels Angles represent the broadest selection of cold formed substructural components in the industry McElroy s new XL line adds capabilities down to 10 gauge and up to 24 web widths CEE ZEE EAVE STRUT Cee Zee and Eave Strut are available in 12 14 and 16 gauge HAT CHANNEL MAC GIRT SUB GIRT Hat Channel Mac Girt and Sub Girt are available in 16 18 and 20 gauge 29

Page 32

Solar Solutions McElroy Metal Peachtree City GA manufacturing plant with McElroy 238T panels and Crystalline solar panels 30

Page 33

Solar Solutions McElroy Metal roofing panels are frequently the host material for crystalline and thin film solar technologies The end result is a functional and environmentally friendly roof system that generates renewable clean green energy Crystalline panels are the most popular photovoltaic product and offer higher efficiency and power generation Crystalline Panels are easily attached to McElroy Metal standing seam systems utilizing S 5 PV Kits which hold the solar panels in place without penetrating the roof Thin film solar laminate solar panels are flexible and adhere directly to many McElroy Metal standing seam systems Because the solar material is adhered directly to the roof panels this technology is referred to as Building Integrated Photovoltaic BIPV Thin film solar panels are lightweight aesthetically appealing and have an ability to generate power under cloudy conditions Crystalline Panels S 5 PV Kit Thin film Solar Laminate 31

Page 34

Green Span Profiles 32

Page 35

Green Span Profiles Green Span Profiles GSP is a McElroy Metal joint venture company that manufactures Insulated Metal Panels IMP s in a state of the art manufacturing facility in Waller TX Insulated Metal Panels are premier building products on the leading edge of innovation Panels are formed by a continuous poured in place manufacturing process which binds interior and exterior steel facings to a polyisocyanurate insulating foam core Green Span Profiles GSPs offer exceptional insulating properties R 8 per inch superior spanning superior spanning capability accelerated installation times and an attractive architectural appearance GSP wall panels can be installed both vertically and horizontally Green Span Profiles are available in 2 2 5 3 4 5 and 6 inch thickness Green Span s RidgeLine roof panel features a 238T symmetrical standing seam making it the industry s easiest IMP to install RidgeLine is available with a 42 cover width in thicknesses from 2 1 2 to 5 Ridgeline Mesaline Waveline Shadowline Impression 33

Page 36

Slit Coils Flat Sheets Perforated McElroy s slit coils and flat sheets are available in a wide variety of widths and gauges in Kynar 500 colors This five story parking garage in Austin Texas was created with custom colors on perforated panels from McElroy Metal address 1500 Hamilton RD Bossier City LA 71111 phone email fax web 318 747 8000 318 747 8029 info mcelroymetal com www mcelroymetal com MM101 Rev 4 19

ACR METAL ROOFING & SIDING
DISTRIBUTORS

info@acrmetal.com

(717) 933-7044
4976 PA-419, Womelsdorf, PA 19567