Return to flip book view

M2 Electrical New M2 Ranges

Page 1

Installation Materials Division...the name behind the brandsPRODUCTCATALOGUEWiring AccessoriesConsumer UnitsCircuit Protection®

Page 2

Page 3

CONSUMER UNITS & CIRCUIT PROTECTION DEVICES Section ContentM2 offer a comprehensive range of consumer units and short circuit protective devices for the domestic market that have many features to aid the installation. The dual screw main switch isolator offers unrivalled performance for meter tails connections, whilst the unique bus bar system provide quick and easy installation of devices. In addition, our extensive range of compact RCBO devices now feature a 45A rated device. At M2, it is a matter of safety and our product features and benefits have been developed following research carried out by leading industry bodies. Our commitment to change has been a deciding factor for many esteemed housing associations to choose M2 as their primary switchgear manufacturer.Metalclad Consumer Units 2 Insulated Consumer Units 12 Accessories 14Circuit Protection Devices 16 Surge Protection Devices 19 Technical Information 22IP67 Rotary Isolators 20®230V SWITCHGEAR 400V SWITCHGEAR3

Page 4

4M2 | SELECTION AND CONFIGURATIONSMetalclad Consumer UnitsSee page 114 for Metalclad boards (120 for insulated boards)See page 115 for Metalclad boards (121 for insulated boards)• Is the Consumer Unit being installed in a domestic (household) premise (Reg. 421.1.201), i.e. metalclad consumer unit?• To avoid hazards and minimise inconvenience in the event of a fault, take into account the danger caused by failure of a single circuit such as a lighting circuit. Reduce the possibility of tripping of an RCD due to excessive protective conductor currents (Reg. 314.1).This guide to Consumer Units has been compiled in order to assist in understanding the new wiring regulations. However it is not intended to be a substitute for BS 7671 which should always be consulted in order to ensure that all installations are constructed in accordance with these regulations.• Socket outlets up to 32A must be protected by a residual-current device (Reg. 411.3.3).• Is Lightning or Surge Protection required under Regulation 443.4 & 5?• Are Arc Fault Detection Devices (AFDDs) required to provide additional protection against fire?RCBO/MCBRCBO/MCBRCBO/MCBRCBO/MCBRCBO/MCBRCBO/MCBRCBO/MCBRCBO/MCBRCBO/MCBRCBO/MCBRCBO/MCBRCBO/MCBNELSPDNDPINCOMERDPRCDMCBMCBMCBMCBMCBMCBMCBMCBMCBMCBMCBNMCBESPDL NEEEEISOLATOR CONTROLLED BOARDRCD CONTROLLED BOARD• Allows the use of single module RCBO devices for individual circuit protection at 30mA• Reduces risk of nuisance tripping• An earth fault on one circuit would not adversely affect other circuits in the installation• Can be used as main domestic Consumer Unit• Suitable for Grouped Circuit Protection of small numbers of circuits, usually downstream of main consumer unit• Typical applications include garages, showers and small extensions• If fed from main Consumer Unit also with RCD protection, earth leakage discrimination must be considered• Can be used as sub-distribution board, but should not be used as main domestic Consumer Unit

Page 5

5 | M2M2N3N2N2N1SELECTION AND CONFIGURATIONSMetalclad Consumer UnitsSee page 116 for Metalclad boardsSee page 117 for Metalclad boardsSee page 126 for Combined AFD/RCBOsSee page 118 for Metalclad boardsDUAL RCD BOARDHIGH INTEGRITY DUAL RCD BOARD• High Integrity circuit ways off the isolator are available for dedicated circuit protection - i.e. Smoke Alarms• Dual 30mA RCD configuration offering Grouped Circuit Protection• Circuits can be segregated to reduce unwanted tripping• Can be used as main domestic Consumer Unit• Offers Grouped Circuit Protection using two 30mA RCDs• Circuits can be segregated to reduce unwanted tripping, for example upstairs lights + downstairs ring main off RCD1 and downstairs lights + upstairs ring main off RCD2• Can be used as main domestic Consumer UnitDUAL TARIFF BOARD• For segregation of On Peak and Off Peak circuits• Optional split load and isolator incomer options available• Additional configurations available upon request• Can be used as main domestic Consumer UnitAFDD BOARD• For compliance to Regulation 421.1.7 - recommended use of Arc Fault Detection Devices as a means of providing additional protection against fire caused by arc faults in final AC circuits• Use standard Isolator Controlled Consumer Units and fit 1 module combined AFD/RCBO Devices offering Arc Fault, Earth Leakage, Overload and Short Circuit protection• Can be used as main domestic Consumer UnitDPISOLATORMCBMCBMCBMCBMCBMCBMCBN1MCBESPDL NDPRCDDPRCDN2DPISOLATORMCBMCBMCBMCBMCBMCBN2ESPDL NDPRCDDPRCDN3RCBO/MCBRCBO/MCBN1EEEEERCBO/MCBRCBO/MCBRCBO/MCBRCBO/MCBRCBO/MCBRCBO/MCBRCBO/MCBRCBO/MCBRCBO/MCBRCBO/MCBLSPDNDPINCOMERDPINCOMERNEN NESupplyL1SupplyL2Supply NNEDPINCOMERRCBO/AFDDRCBO/AFDDRCBO/AFDDRCBO/AFDDSupplyL NRCBORCBORCBORCBORCBORCBO

Page 6

6M2 | METALCLAD CONSUMER UNIT FEATURESThe new range of Metalclad Consumer Units from M2 Electrical have been designed in conjunction with contractors and housing authorities specifically to meet the requirements of BS7671 - The Wiring Regulations. The M2 XS dual screw terminal isolator with a 35mm2 terminal capacity offers protection for nearly double the average strip length, improving cable contact within the terminal and its circular terminal design reduces cable strand spread.With its linear design and matt white (RAL9010) finish, the consumer unit offers the home owner a discreet and contemporary product, whilst providing suitable protection to meet today’s need.Regulation 421.1.201 calls for switchgear assemblies - including consumer units, to KEYFEATURES:AM2X METALCLADRANGEFEATURES:Metalclad Consumer Unitsbe housed in a non-combustible enclosure, incorporating the base, cover, door and any accessories. The M2XS range meets these requirements and offers additional features providing a more versatile product.

Page 7

7 | M2M2METALCLAD CONSUMER UNIT FEATURESPatented terminal design.OFFERING A COMPREHENSIVE RANGE1.3.Dual Screw Termination4.3.4.NEW compact220mm high consumer units.7.Easy access for meter tail connections.6.Bespoke consumer units made to order.8.1.Dual Screw TerminationSteel cam lock with optional retrofit key lock. 5.Removable blank for SPD installation.2.18th Edition Compliant2.Metalclad Consumer UnitsAdded cabling capacity.Comb bus bar / Half Din Rail for quick fitting of devices.Preformed cablesInstallation of Devices

Page 8

8M2 | ISOLATOR INCOMER CONSUMER UNITSISOLATOR CONTROLLED CONSUMER UNITS* - Double banked.Metalclad Consumer UnitsMeasurements:Millimeters (mm) unless stated otherwiseCircuit Protection Devices:Please refer to page 124 FEATURES:O/G WAYS ISOLATOR RATING WITHOUT SPDCAT. NO.H W D2 63A AM2X2MU - 220 115 854 100A AM2X4MU AM2X4MUT2 220 201 1106 100A AM2X6MU AM2X6MUT2 220 273 1108 100A AM2X8MU AM2X8MUT2 220 273 11010 100A AM2X10MU AM2X10MUT2 220 309 11011 100A AM2X11MU AM2X11MUT2 220 335 11012 100A AM2X12MU AM2X12MUT2 220 381 11014 100A AM2X14MU AM2X14MUT2 220 381 11016 100A AM2X16MU AM2X16MUT2 220 417 11020 100A AM2X20MU AM2X20MUT2 220 489 11022 100A AM2X22M* AM2X22MT2* 500 309 11026 100A AM2X26MU AM2X26MUT2 220 597 11030 100A AM2X30M* AM2X30MT2* 500 381 11034 100A AM2X34M* AM2X34MT2* 500 417 110LIFT UPLIDS63A / 100A Double Pole Switch Disconnector Incomer Metalclad Consumer Unit• Incoming Isolator fitted can be a choice of either 45A (on request), 63A, or 100A• Units will accept 6 kA and 10 kA MCBs and RCBOs • Non-combustible enclosureFor TYPE 1 lightning protection replace suffix T2 for T1WITH SPDTYPE 2CAT. NO.18thCOMPLIANTFor TYPE 2+3 overvoltage transient replace suffix T2 for T23AM2X14MUT2The M2 range of metal consumer units are designed and manufactured to BSEN 61439 pt 3 and meets the requirements of BS 7671 regulation 421.1.201 - effects against thermal influences specifically for domestic household dwellings. Manufactured from steel and finished in a polyester powder coating to RAL9010, the M2 range provides a comprehensive selection of products to meet the customers requirements.

Page 9

9 | M2M2RCD INCOMER CONSUMER UNITS* - 30mA trip rating.RCD INCOMER CONSUMER UNITSThe M2 range of Type A RCD incomer metalclad consumer units are available with 63A, 80A and 100A RCD incomer ratings and 30mA earth leakage protection. For 100mA earth leakage protection or Type AC, please contact our sales office for further details on 01527 520 678.Measurements:Millimeters (mm) unless stated otherwiseCircuit Protection Devices:Please refer to page 124Metalclad Consumer UnitsFEATURES:O/G WAYS RCD 1 RATING* WITHOUT SPDCAT. NO.H W D2 63A AM2R632MA - 220 115 854 63A AM2R634MUA AM2R634MUAT2 220 201 1106 63A AM2R636MUA AM2R636MUAT2 220 273 1108 63A AM2R638MUA AM2R638MUAT2 220 273 11012 63A AM2R6312MUA AM2R6312MUAT2 220 381 1102 80A AM2R802MA - 232 149 1104 80A AM2R804MUA AM2R804MUAT2 220 201 1106 80A AM2R806MUA AM2R806MUAT2 220 273 1108 80A AM2R808MUA AM2R808MUAT2 220 273 11012 80A AM2R8012MUA AM2R8012MUAT2 220 381 1104 100A AM2R1004MUA AM2R1004MUAT2 220 201 1106 100A AM2R1006MUA AM2R1006MUAT2 220 273 1108 100A AM2R1008MUA AM2R1008MUAT2 220 273 11012 100A AM2R10012MUA AM2R10012MUAT2 220 381 110TYPE A RCD63A / 100A 30mA RCD Incomer Metalclad Consumer Unit • 63A, 80A or 100A Type A 30mA DP RCD incomer• Optional key lock availableWITH SPDTYPE 2CAT. NO.18thCOMPLIANTFor TYPE 1 lightning protection replace suffix T2 for T1For TYPE 2+3 overvoltage transient replace suffix T2 for T23AM2R8012MUA

Page 10

10M2 | DUAL RCD CONSUMER UNITSAM2X66TRMUAT1Metalclad Consumer UnitsMeasurements:Millimeters (mm) unless stated otherwiseCircuit Protection Devices:Please refer to page 124 FEATURES:This selection of Consumer Units offer the facility to spread the load circuits across one or two 30mA RCDs. * - 30mA trip rating.DUAL RCD CONSUMER UNITS• Supplied with 2x Type A 30mA RCDs, 1x 100A DP isolator and full complement of earth and neutral terminals along with marking labels, busbar and instructions• Non-combustible enclosureMetalclad Consumer Units Dual RCD ControlledO/G WAYSISOLATOR RATINGRCD 1 RATING*RCD 2 RATING*WITHOUT SPDCAT. NO.H W D6 100A 63A 63A AM2X33TRMUA AM2X33TRMUAT2 220 309 11010 100A 63A 63A AM2X55TRMUA AM2X55TRMUAT2 220 381 11010 100A 100A 100A AM2X55TRMUNA AM2X55TRMUNAT2 220 381 11012 100A 80A 80A AM2X66TRMUA AM2X66TRMUAT2 220 417 11012 100A 100A 100A AM2X66TRMUNA AM2X66TRMUNAT2 220 417 11016 100A 80A 80A AM2X88TRMUA AM2X88TRMUAT2 220 489 11016 100A 100A 100A AM2X88TRMUNA AM2X88TRMUNAT2 220 489 11020 100A 80A 80A AM2X1010TRMUA AM2X1010TRMUAT2 220 597 11020 100A 100A 100A AM2X1010TRMUNA AM2X1010TRMUNAT2 220 597 11022 100A 80A 80A AM2X1111TRMUA AM2X1111TRMUAT2 220 597 11022 100A 100A 100A AM2X1111TRMUNA AM2X1111TRMUNAT2 220 597 110In addition, our standard range of dual RCD consumer units are available with SPDs pre-fitted.WITH SPDTYPE 2CAT. NO.18thCOMPLIANTTYPE A RCDFor TYPE 1 lightning protection replace suffix T2 for T1For TYPE 2+3 overvoltage transient replace suffix T2 for T23

Page 11

11 | M2M2AM2X44TR2MUAT2HIGH INTEGRITY CONSUMER UNITSMeasurements:Millimeters (mm) unless stated otherwiseCircuit Protection Devices:Please refer to page 124Metalclad Consumer UnitsFEATURES:For applications where ‘High Integrity’ circuit protection is required - such as smoke detectors, these units allow dedicated RCBO installation.Standard configurations listed below supplied with DP isolator and RCD/s factory fitted, link leads for both live and neutral connections also pre-installed.HIGH INTEGRITY DUAL RCD CONSUMER UNITS* - 30mA trip rating. • Supplied with 2x Type A 30mA RCD’s, 1x 100A DP Isolator and full complement of earth and neutral terminals along with marking labels, bus bar and instructions• Non-combustible enclosure• DSLV units are flexible/variableDual RCD High Integrity Metalclad Consumer UnitO/G WAYSISOLATOR RATINGRCD 1 RATING*RCD 2 RATING*WITHOUT SPD CAT. NO.H W D6 100A 63A 63A AM2X23TR1MUA AM2X23TR1MUAT2 220 309 11010 100A 63A 63A AM2X44TR2MUA AM2X44TR2MUAT2 220 381 11012 100A 63A 63A AM2X55TR2MUA AM2X55TR2MUAT2 220 417 11014 100A 63A 63A AM2X66TR2MUA AM2X66TR2MUAT2 220 489 11020 100A 80A 80A AM2X88TR4MUA AM2X88TR4MUAT2 220 597 1106 100A 63A 63A AM2XDSLV6UA AM2XDSLV6UAT2 220 309 11010 100A 63A 63A AM2XDSLV10UA AM2XDSLV10UAT2 220 381 11010 100A 100A 100A AM2XDSLV10UNA AM2XDSLV10UNAT2 220 381 11012 100A 80A 80A AM2XDSLV12UA AM2XDSLV12UAT2 220 417 11012 100A 100A 100A AM2XDSLV12UNA AM2XDSLV12UNAT2 220 417 11016 100A 80A 80A AM2XDSLV16UA AM2XDSLV16UAT2 220 489 11016 100A 100A 100A AM2XDSLV16UNA AM2XDSLV16UNAT2 220 489 11022 100A 80A 80A AM2XDSLV22UA AM2XDSLV22UAT2 220 597 11022 100A 100A 100A AM2XDSLV22UNA AM2XDSLV22UNAT2 220 597 110WITH SPD TYPE 2CAT. NO.18thCOMPLIANTFor TYPE 1 lightning protection replace suffix T2 for T1For TYPE 2+3 overvoltage transient replace suffix T2 for T23TYPE A RCD

Page 12

12M2 | AM2X6DT6UON PEAK OFF PEAK WITHOUT SPD CAT. NO. H W D100A isolator 6 ways 100A isolator 6 ways AM2X6DT6U AM2X6DT6UT2 256 381 110100A isolator 8 ways 100A isolator 4 ways AM2X8DT4U AM2X8DT4UT2 256 381 110100A isolator 10 ways 100A isolator 4 ways AM2X10DT4U AM2X10DT4UT2 256 417 110100A isolator 12 ways 100A isolator 6 ways AM2X12DT6U AM2X12DT6UT2 256 489 110LIFT UPLIDSDUAL TARIFF CONSUMER UNITS• Available in bespoke configurations• Suitable for Multi-Tariff installations• Optional Surge Protection Device (SPD) fittedContact factory for details on Surge Protection for your Dual Tariff Consumer UnitWITH SPD TYPE 2CAT. NO.18thCOMPLIANTAM2XSLV6MUASPLIT LOAD CONSUMER UNITS• Supplied with 1x 30mA RCDs, 1x 100A DP isolator and full complement of earth and neutral terminals along with marking labels, busbar and instructions• Non-combustible enclosureAmendment 3 Metalclad Consumer Units Split LoadO/G WAYS ISOLATOR RATING RCD 1 RATING* WITHOUT SPD CAT. NO.H W D6 100A 63A AM2XSLV6MUA AM2XSLV6MUAT2 220 273 11012 100A 63A AM2XSLV12MUA AM2XSLV12MUAT2 220 381 110LIFT UPLIDS* - 30mA trip rating.WITH SPD TYPE 2CAT. NO.18thCOMPLIANTFor TYPE 1 lightning protection replace suffix T2 for T1For TYPE 2+3 overvoltage transient replace suffix T2 for T23For TYPE 1 lightning protection replace suffix T2 for T1For TYPE 2+3 overvoltage transient replace suffix T2 for T23DUAL TARIFF & SPLIT LOAD CONSUMER UNITSMetalclad Consumer UnitsMeasurements:Millimeters (mm) unless stated otherwiseCircuit Protection Devices:Please refer to page 124 FEATURES:Our standard range of dual tariff consumer units provide dedicated segregation of on peak and off peak circuits.

Page 13

13 | M2M2ASM16UGARAGE & SHOWER UNITSAM2GUAFEATURES:To compliment the M2 range of metalclad consumer units, a selection of spacer mounts are available for use where retrofitting to surface mount cables are necessary. In addition, meter tail glands are available for providing Class II insulation protection for incoming supply cables. • Full steel door with fitted cam lock• Amendment 3 compliant• Non-combustible enclosureO/G WAYS RCD 1 RATING*MCB RATINGCAT. NO. H W D2 40A 6A + 16A AM2GUA 220 115 854 40A 6A + 16A AM2GU4A 220 201 1101 40A 40A AM2SU95A 220 115 851 63A 50A AM2SU115A 232 150 110NO. of MODULES BANKS CAT. NO. H W D6 1 ASM6U 220 201 3010 1 ASM10U 220 273 3012 1 ASM12U 220 309 3016 1 ASM16U 220 381 3018 1 ASM18U 220 417 3022 1 ASM22U 220 489 3028 1 ASM28U 220 597 30CONSUMER UNIT SPACER MOUNTSFor 6 - 28 Module Metalclad BoardsDESCRIPTION CAT. NO. DIA2x 25mm / 1x 16mm M32 - brass MTGP32B 322x 25mm / 1x 16mm M40 - brass MTGP40B 402x 25mm / 1x 16mm M32 - plastic MTGP32P 322x 25mm / 1x 16mm M40 - plastic MTGP40P 40SAFETY ACCESSORIESAKLMTGP40BMETER TAIL GLAND PACKSDESCRIPTION CAT. NO.Key operated lock assembly AKLIntumescent putty pad (210mm x 148mm x 3mm)IP21X15Metalclad Consumer UnitsFor more information contact our sales office or see below.CONSUMER UNITSPACER MOUNTASM6U ASM10U ASM12U ASM16U ASM18U ASM22U ASM28UISOLATOR CONTROLLED 4 Way 6 + 8 Way 10 Way 12/14 Way 16 Way 20 Way 26 WayRCD CONTROLLED 4 Way 6 + 8 Way 10 Way 12 Way - - -DUAL RCD - - 6 Way 10 Way 12 Way 16 Way 22 WayHIGH INTEGRITY - - 6 Way 10 Way 12 Way 16 Way 22 Way* - 30mA trip rating.Measurements:Millimeters (mm) unless stated otherwiseCircuit Protection Devices:Please refer to page 124METALCLAD ACCESSORIES

Page 14

14M2 | ISOLATOR INCOMER CONSUMER UNITSISOLATOR CONTROLLED CONSUMER UNITSM2X10IReadily available from 1 to 23 usable ways, our isolator incomer consumer units allow the use of single module RCBO devices for individual circuit protection at 30mA, reducing the risk of nuisance tripping. Our ranges of isolator incomer consumer units are pre-fitted with a unique dual screw terminal double-pole mains isolator switch for an increased level of consumer safety, with ratings ranging from 45A – 100A. Our insulated enclosures are manufactured from light grey impact resistant and flame retardant thermoplastic.Insulated Consumer UnitsMeasurements:Millimeters (mm) unless stated otherwiseCircuit Protection Devices:Please refer to page 124 FEATURES:O/G WAYS ISOLATOR RATING NO. of MODULES CAT. NO. H W D1 D21 45A 4 M2X1I 230 116 110 2202 63A 4 M2X2I 230 116 110 2203 63A 6 M2X3I 230 152 110 2204 100A 6 M2X4I 230 152 110 2208 100A 12 M2X8I 230 285 110 22010 100A 12 M2X10I 230 285 110 22014 100A 18 M2X14I 230 390 110 22016 100A 18 M2X16I 230 390 110 22021 100A 25 M2X21I 230 511 110 22023 100A 25 M2X23I 230 511 110 22045A / 63A / 100A Double Pole Switch Disconnector Incomer Insulated Consumer Units• Isolator controlled insulated consumer units, offering a range of outgoing circuits from 1 to 23• Incoming Isolators fitted range from 45A to 100A• Units will accept MCBs & RCBOsHWD1D2

Page 15

15 | M2M2Readily available from 1 to 10 usable ways, our Type A RCD incomer consumer units are suitable for grouped circuit protection for a small number of circuits, typically installed in addition to a property’s main consumer unit – applications such as garages, showers and small extensions. Our ranges of RCD incomer consumer units are pre-fitted with a 30mA RCD incomer, with ratings ranging from 40A – 100A. RCD CONTROLLED CONSUMER UNITSRCD CONTROLLED CONSUMER UNITSM2R808ABuild your own consumer unit or multi-purpose board. Simply clip on your required equipment to the DIN Rail and if necessary fit the Comb Busbar. Fitted with full DIN rail, Earth and Neutral terminal bars. DIN RAIL ENCLOSURESM2E18Measurements:Millimeters (mm) unless stated otherwiseCircuit Protection Devices:Please refer to page 124Insulated Consumer UnitsFEATURES:O/G WAYS ISOLATOR RATINGNO. of MODULESCAT. NO. H W D1 D22 40A 4 M2R402A 230 116 110 2202 63A 4 M2R632A 230 116 110 2204 63A 6 M2R634A 230 152 110 2208 63A 12 M2R638A 230 285 110 2204 80A 6 M2R804A 230 152 110 2208 80A 12 M2R808A 230 285 110 22010 80A 12 M2R8010A 230 285 110 2208 100A 12 M2R1008A 230 285 110 22010 100A 12 M2R10010A 230 285 110 22040A / 63A / 80A / 100A Type A 30mA RCD Incomer Metalclad Consumer Units• RCD controlled insulated consumer units, offering a range of outgoing circuits from 1 to 10• 40A / 63A / 100A 30mA DP RCD incomer• Units will accept MCBsNO. of MODULES CAT. NO. H W D1 D24 M2E4 230 116 110 2206 M2E6 230 152 110 22012 M2E12 230 285 110 22018 M2E18 230 390 110 22025 M2E25 230 511 110 220HWD1D2HWD1D2TYPE A RCD

Page 16

16M2 | ACCESSORIES80A max. 100A intermittent rating.CB19SPMeasurements:Millimeters (mm) unless stated otherwiseAccessoriesDESCRIPTION CAT. NO.Blanking plate B1DESCRIPTION CAT. NO.Blanking module BM1DESCRIPTION CAT. NO.Busbar terminal shroud BBS1DESCRIPTION CAT. NO.MCB Dolly locking device DLPX1MCB Dolly locking device c/w padlockDLPX1PBLANKING MODULEBUSBAR TERMINAL SHROUDBLANKING PLATEDLPX1PLOCKING DEVICESDESCRIPTION CAT. NO.19 Ways, single pole CB19SP28 Ways, single pole CB28SPINSULATED COMB BUSBARSSINGLE POLEDESCRIPTION CAT. NO.End Cap For DP/TP Insulated comb busbarCBC3END CAPDESCRIPTION CAT. NO.2 Module blanking plate MB2METAL BLANKING PLATE

Page 17

17 | M2M2CASE STUDY:East Suffolk Council selected M2 XS 18th Edition-compliant consumer units and M2 white moulded wiring accessories for their local housing specifications. Since specifying M2 Electrical, East Suffolk Council can now purchase their very own, branded Consumer Unit, a 10-way Surge Protected Dual RCD unit, complete with Miniature Circuit Breaker’s and accompanying 16-module Spacer Mount.EAST SUFFOLK COUNCILM2 CONSUMER UNITS & WIRING ACCESSORIESEast Suffolk Council’s previous supplier had a drop in quality and service levels, which prompted them to make a change. With approximately 5,000 properties to work on, the council had the opportunity to work with a British manufacturer offering a 25 year guarantee, based in BESPOKE SOLUTION25 YEAR GUARANTEETECHNICAL SUPPORT FROM MANUFACTURERWorcestershire. M2 Electrical were able to offer a more modern and stylish product than previously installed, which was the key selling point to the engineers.Case Study

Page 18

18M2 | MCBS, RCBOS, COMPACT RCBOS & RCDSM2B32MINIATURE CIRCUIT BREAKERSM26MBRSPKARESIDUAL CURRENT BREAKERS WITH OVERLOADCircuit Protection DevicesMeasurements:Millimeters (mm) unless stated otherwiseCURRENT RATING 6 kA SP B CURVE CAT. NO. 6 kA SP C CURVE CAT. NO.6A M2B6 M2C610A M2B10 M2C1016A M2B16 M2C1620A M2B20 M2C2032A M2B32 M2C3240A M2B40 M2C4050A M2B50 M2C5063A M2B63 M2C63CURRENT RATING6 kA B CURVE CAT. NO.6 kA C CURVE CAT. NO.6 kA B CURVE CAT. NO.6 kA C CURVE CAT. NO.6A M26MBRSP M26MCRSP M26MBRSPA M26MCRSPA10A M210MBRSP M210MBCSP M210MBRSPA M210MBCSPA16A M216MBRSP M216MCRSP M216MBRSPA M216MCRSPA20A M220MBRSP M220MCRSP M220MBRSPA M220MCRSPA32A M232MBRSP M232MCRSP M232MBRSPA M232MCRSPA40A M240MBRSP M240MCRSP M240MBRSPA M240MCRSPA45A M245MBRSP - M245MBRSPA -COMPACT RESIDUAL CURRENT BREAKERS WITH OVERLOADCURRENT RATING6 kA B CURVE CAT. NO.6 kA C CURVE CAT. NO.6 kA B CURVE CAT. NO.6 kA C CURVE CAT. NO.6A M26MBRSPK M26MCRSPK M26MBRSPKA M26MCRSPKA10A M210MBRSPK M210MCRSPK M210MBRSPKA M210MCRSPKA16A M216MBRSPK M216MCRSPK M216MBRSPKA M216MCRSPKA20A M220MBRSPK M220MCRSPK M220MBRSPKA M220MCRSPKA32A M232MBRSPK M232MCRSPK M232MBRSPKA M232MCRSPKA40A M240MBRSPK M240MCRSPK M240MBRSPKA M240MCRSPKA45A M245MBRSPK M245MCRSPK M245MBRSPKA M245MCRSPKAM26MBRSPATYPE AC TYPE A TYPE AC TYPE A SINGLE MODULE RCBOs - DOUBLE POLECURRENT RATING 6 kA B CURVE COMP. CAT. NO.6A M21BK610A M21BK1016A M21BK1620A M21BK2032A M21BK3240A M21BK40M21BK10TYPE A

Page 19

19 | M2M2ISOLATORSM2100HM240230RESIDUAL CURRENT DEVICES 2 POLELower current rated DP RCD units are available in Type A on request.Measurements:Millimeters (mm) unless stated otherwiseCircuit Protection DevicesCURRENT RATING MAX. CABLE SIZE mm230mA TYPE AC CAT. NO.30mA TYPE A CAT. NO.32A 50 M232230 -40A 50 M240230 M240230A63A 50 M263230 M263230A80A 50 M280230 M280230A100A 50 M2100230 M2100230ACURRENT RATING M2XS CAT. NO.63A M263H100A M2100HISOLATORS63A / 100A Dual Screw Mains Isolator Switch. • Patented design• Dual screw terminals specifically developed for incoming supply cables• The circular cross section tunnel matches that of the conductor cable• Extended terminal length for greater connectivity• Accepts up to 35mm2 meter tails• IP20 ratedGREATERCONNECTIVITYPATENTEDDESIGNPatented dual screw terminal design.1.1.Patented3.3.For increased safety and a superior connection.2.Dual Screw Termination4.Added cabling capacity.Circular Cross Section TerminalGreater connectivity ensuring cables are held far more securely.4.Increased Terminal Length2.TYPE AC TYPE A

Page 20

20M2 | • 6A-40A Rated• Series and parallel arc fault detection• 30mA earth leakage Type A• B and C curve tripping characteristics• Switched Live & Neutral• Fits existing busbar system• Self testing (AFDD function only)COMPLETE CIRCUIT PROTECTIONAn arc-fault occurs when loose or corroded connections make intermittent contact and causes sparking or arcing between the connections. This translates into heat, which will break down the insulations of the wire and potentially trigger for an electrical fire. Such arc’s can range in power and vary a great deal in strength and duration. Potential causes of arc faults could include:-WHAT IS AN ARC FAULT?WHAT IS AN AFR?The M2 AFR is an arc fault detection device combined with short circuit, overload and earth leakage detection.Trapped/damaged cablesCable wear Damage caused by construction workLoose terminationsArc Fault Detection Devices use digital electronics to analyse the waveform of an A.C. circuit to detect arc faults. The device continuously monitors the circuit for different variations including the duration of an arc and the waveform. Once the device detects an irregular fault the device trips and disconnects the circuit, reducing the chance of it over heating and potentially causing an electrical fire.WHAT IS AN AFDD?PARALLEL ARC FAULT SERIES ARC FAULTSeries arc faults are found in loose terminal connections, damaged cords or frayed/damaged conductors. These arc’s are created in one conductor only, either phase or neutral.Parallel arc faults are found with damage caused to insulation which allows current to flow between conductors, usually between phase and neutral.CURRENT RATINGKA RATING B CURVE CAT. NO.C CURVE CAT. NO.6A 6 M2AFR06B1 M2AFR06C110A 6 M2AFR10B1 M2AFR10C116A 6 M2AFR16B1 M2AFR16C120A 6 M2AFR20B1 M2AFR20C132A 6 M2AFR32B1 M2AFR32C140A 6 M2AFR40B1 M2AFR40C1M2 offer a range of combined Arc Fault Detection (AFD) and Residual Current Circuit Breaker with Overload (RCBO) devices in B & C curve with Type A 30mA earth leakage.The single module device is designed to fit single and three phase distribution boards without the need to modify the bus bar fixing. MCBRCDAFD/RCBOEARTH LEAKAGERCBOARC FAULTOVERCURRENTSHORT CIRCUITAFDDMCBProtection against overcurrent and short circuitRCDProtection against earth leakageRCBOProtection against overcurrent, short circuit and earth leakageAFDDProtection against arc faultAFD/RCBOComplete comprehensive circuit protectionM2AFR06B1ARC FAULT DETECTION DEVICESCircuit Protection DevicesMeasurements:Millimeters (mm) unless stated otherwise

Page 21

21 | M2M2SURGE PROTECTION DEVICESMeasurements:Millimeters (mm) unless stated otherwiseSurge Protection Devices SPD/T12Designation according to EN 61643-11 Type 1+2Nominal voltage AC 50-60 Hz Un [V] 230/-Maximum continuous operating voltage (L-N) Uc (L-N) [V] 275Lightning impulse current (10/350) (L-N) limp (L-N) [kA] 12,5Lightning impulse current (10/350) (N-PE) limp (N-PE) [kA] 25Maximum discharge current (8/20) (L-N) Imax (L-N) [kA] 50Maximum discharge current (8/20) (N-PE) Imax (N-PE) [kA] 50Nominal discharge current (8/20) (L-N) In (L-N) [kA] 20Nominal discharge current (8/20) (N-PE) In (N-PE) [kA] 25Voltage protection level (L-N) at In Up (L-N) [kV] ≤1,3Maximum back-up fuse A [gL] 200Short circuit withstand Icc [kA] 25SPD TYPENO. of POLESSINGLE PHASE CAT. NO.1 + 2 2 M2SPD/T12SINGLE PHASE TYPE 1 + 2 SPDSPD/T2 SPD/T23Designation according to EN 61643-11 Type 2 Type 2+3Nominal voltage AC 50-60 Hz Un [V] 230/- 230/-Maximum continuous operating voltage (L-N) Uc (L-N) [V] 275 275Maximum discharge current (8/20) (L-N) Imax (L-N) [kA] 40 15Nominal discharge current (8/20) (L-N) In (L-N) [kA] 20 5Voltage protection level (L-N) at In Up (L-N) [kV] ≤1,3 ≤1,2Voltage protection level (N-PE) at In Up (N-PE) [kV] ≤1,5 ≤1,5Maximum back-up fuse A [gL] 125 63Short circuit withstand Icc [kA] 25 10SPD TYPE NO. of POLES SINGLE PHASE CAT. NO.2 2 M2SPD/T2SINGLE PHASE TYPE 2 SPDSPD TYPE NO. of POLES SINGLE PHASE CAT. NO.2 + 3 2 M2SPD/T23SINGLE PHASE TYPE 2 + 3 SPDCOMBINED TYPE 1 + 2TYPE 2 & COMBINED TYPE 2 + 3SPD’S IN INSULATED IP RATED ENCLOSURESSPD TYPE IP RATING CAT. NO. H W D1 + 2 IP65 M2SPD/T12E 150 100 1002 IP65 M2SPD/T2E 150 100 1002 + 3 IP65 M2SPD/T23E 150 100 100SPD/T2E

Page 22

22M2 | ROTARY ISOLATORS3 POLE IP67 ROTARY ISOLATORS4 POLE IP67 ROTARY ISOLATORSM2 Electrical, Pipers Road, Park Farm Industrial Estate, Redditch, Worcestershire. B98 0HU. Web: www.m2electrical.co.uk Email: sales@m2electrical.co.uk Product Data Sheet Product Code: M21003 Issue No. Issue Date: Issue by: A 06/10/2017 T. Tombs Description 100A 3 pole switch disconnector with neutral and earth clamps in IP67 insulated enclosure. Key Dimensions Fixing centres. Additional information. Usage Intended for use by skilled persons or instructed persons. Electrical Earth & Neutral terminals Rated frequency: 50 / 60 Hz. Rated operational voltage: 690V ac maximum Rated insulation voltage (Ui): 800V Rated impulse voltage (U imp): 8 kV Earthing system: EMC environment: Environment type A. Physical Ambient operating temperature -25 to 40 °C. These isolators should not be operated when submerged. Maximum altitude: 3000m. Enclosure: Glass fibre reinforced polyester. Installation Service conditions: Wiring of this product must comply with current IEE regulations. Units are intended for indoor use and NOT where high levels of humidity and temperature are experienced. Note: IP rating of enclosures can be compromised if correct use of glands is not followed when installing unit. IP67 definition: 6 - Completely protected against dust ingress. 7 - Temporary protection against immersion in water up to 1m depth (water must not penetrate in harmful quantities in prescribed conditions). M2 Electrical, Pipers Road, Park Farm Industrial Estate, Redditch, Worcestershire. B98 0HU. Web: www.m2electrical.co.uk Email: sales@m2electrical.co.uk Product Data Sheet Product Code: M21003 Issue No. Issue Date: Issue by: A 06/10/2017 T. Tombs Description 100A 3 pole switch disconnector with neutral and earth clamps in IP67 insulated enclosure. Key Dimensions Fixing centres. Additional information. Usage Intended for use by skilled persons or instructed persons. Electrical Earth & Neutral terminals Rated frequency: 50 / 60 Hz. Rated operational voltage: 690V ac maximum Rated insulation voltage (Ui): 800V Rated impulse voltage (U imp): 8 kV Earthing system: EMC environment: Environment type A. Physical Ambient operating temperature -25 to 40 °C. These isolators should not be operated when submerged. Maximum altitude: 3000m. Enclosure: Glass fibre reinforced polyester. Installation Service conditions: Wiring of this product must comply with current IEE regulations. Units are intended for indoor use and NOT where high levels of humidity and temperature are experienced. Note: IP rating of enclosures can be compromised if correct use of glands is not followed when installing unit. IP67 definition: 6 - Completely protected against dust ingress. 7 - Temporary protection against immersion in water up to 1m depth (water must not penetrate in harmful quantities in prescribed conditions). HW DIP67 Rotary IsolatorsMeasurements:Millimeters (mm) unless stated otherwiseCURRENT RATING AC23A 415 VPOWER AT 415 V (kW)POWER AT 690 V (kW)MAX. CABLE mm2CAT. NO. H W D20A 11 15 10 M2203 160 105 12732A 18.5 15 10 M2323 160 105 12763A 37 37 35 M2633 210 135 127100A 55 55 35 M21003 329 205 154CURRENT RATING AC23A 415 VPOWER AT 415 V (kW)POWER AT 690 V (kW)MAX. CABLE mm2CAT. NO. H W D20A 11 15 10 M2204 160 105 12732A 18.5 15 10 M2324 160 105 12763A 37 37 35 M2634 210 135 127100A 55 55 35 M21004 329 205 154M2323M2634M2 Electrical, Pipers Road, Park Farm Industrial Estate, Redditch, Worcestershire. B98 0HU. Web: www.m2electrical.co.uk Email: sales@m2electrical.co.uk Product Data Sheet Product Code: M21003 Issue No. Issue Date: Issue by: A 06/10/2017 T. Tombs Description 100A 3 pole switch disconnector with neutral and earth clamps in IP67 insulated enclosure. Key Dimensions Fixing centres. Additional information. Usage Intended for use by skilled persons or instructed persons. Electrical Earth & Neutral terminals Rated frequency: 50 / 60 Hz. Rated operational voltage: 690V ac maximum Rated insulation voltage (Ui): 800V Rated impulse voltage (U imp): 8 kV Earthing system: EMC environment: Environment type A. Physical Ambient operating temperature -25 to 40 °C. These isolators should not be operated when submerged. Maximum altitude: 3000m. Enclosure: Glass fibre reinforced polyester. Installation Service conditions: Wiring of this product must comply with current IEE regulations. Units are intended for indoor use and NOT where high levels of humidity and temperature are experienced. Note: IP rating of enclosures can be compromised if correct use of glands is not followed when installing unit. IP67 definition: 6 - Completely protected against dust ingress. 7 - Temporary protection against immersion in water up to 1m depth (water must not penetrate in harmful quantities in prescribed conditions). M2 Electrical, Pipers Road, Park Farm Industrial Estate, Redditch, Worcestershire. B98 0HU. Web: www.m2electrical.co.uk Email: sales@m2electrical.co.uk Product Data Sheet Product Code: M21003 Issue No. Issue Date: Issue by: A 06/10/2017 T. Tombs Description 100A 3 pole switch disconnector with neutral and earth clamps in IP67 insulated enclosure. Key Dimensions Fixing centres. Additional information. Usage Intended for use by skilled persons or instructed persons. Electrical Earth & Neutral terminals Rated frequency: 50 / 60 Hz. Rated operational voltage: 690V ac maximum Rated insulation voltage (Ui): 800V Rated impulse voltage (U imp): 8 kV Earthing system: EMC environment: Environment type A. Physical Ambient operating temperature -25 to 40 °C. These isolators should not be operated when submerged. Maximum altitude: 3000m. Enclosure: Glass fibre reinforced polyester. Installation Service conditions: Wiring of this product must comply with current IEE regulations. Units are intended for indoor use and NOT where high levels of humidity and temperature are experienced. Note: IP rating of enclosures can be compromised if correct use of glands is not followed when installing unit. IP67 definition: 6 - Completely protected against dust ingress. 7 - Temporary protection against immersion in water up to 1m depth (water must not penetrate in harmful quantities in prescribed conditions). HW D• Modern design and manufacturing process• IP67 ingress protection allows installation in the most severe conditions• Dedicated LOCK OFF position• In LOCK OFF position cover cannot be removed• High switching capability• Strong high impact resistance enclosure20A / 32A / 63A / 100A 3 Pole Rotary Isolator Switch IP67• Modern design and manufacturing process• IP67 ingress protection allows installation in the most severe conditions• Dedicated LOCK OFF position• In LOCK OFF position cover cannot be removed• High switching capability• Strong high impact resistance enclosure20A / 32A / 63A / 100A 4 Pole Rotary Isolator Switch IP67For 500V & 690V ratings refer to datasheetsFor 500V & 690V ratings refer to datasheets

Page 23

23 | M2M2TECHNICAL INFORMATION• Modern design and manufacturing process• IP67 ingress protection allows installation in the most severe conditions• Dedicated LOCK OFF position• In LOCK OFF position cover can not be removed• High switching capability• Strong high impact resistance enclosureAccessories. Ordered separately. 1 No & 1 NC. Part No.: M2A11Auxiliary contact rating: AC-13 - 10A @ 230V ac. AC-15 - 6A @ 230V ac.1 3 5L1 L2 L3E2 4 6T1 T2 T3N1 3 5L1 L2 L3E2 4 6T1 T2 T37L48T4GENERAL CHARACTERISTICSSWITCH CONFIGURATION3 POLE 4 POLEIP67 Rotary IsolatorsSTANDARD BSEN 60947 - 1 & 3. EN 60529VOLTAGE RATING 690V ac maximumENCLOSURE Glass fibre reinforced unsaturated polyester resin. High flame resistance and anti-carbonisation. (PC + ABS)HANDLE 2 Padlock positions in the LOCK OFF position. Padlock not supplied.IP RATING Enclosure - IP67 & switch terminal - IP20IMPACT RESISTANCE IK08POLLUTION DEGREE 3OPERATING TEMPERATURE -25°C to 40°CFRONT COVER Screw fixed cover. 2 screws have sealing facility. Captive cover screwsEQUIPMENT TYPE Fixed stationaryDEVICE RATING3 / 4 Pole switch disconnector 20A, 32A, 63A or 100AROTARY ISOLATORSFEATURES

Page 24

24M2 | TECHNICAL INFORMATIONM2 MCBs are of thermo-magnetic, current limiting type and are available in a range of kA ratings (4.5kA up to 10kA) and operating characteristics (B, C and D Curve). A selection of SP (single pole), DP (double pole) and TP (triple pole) options are offered. 12060201052130105210.50.20.10.050.020.010.0050.0020.0010.0005Seconds Minutes1 2 3 4 5 6 7 8 10 15 20 30 40 50I / InB C D23 4 5 6 7 81GENERAL SPECIFICATION1Steady current value 1.13xIn: t>1hrAll MCBs are capable of carrying full load current continuously (derating factors apply for ambient conditions and no. of circuits within an enclosure).Steady current value 1.45xIn: t<1hr. As load current increases above current rating the thermal release mechanism will disconnect MCB.B-CURVED-CURVEC-CURVE3xIn: 0.1sec<t<45sec (In<=32A)3xIn: 0.1sec<t<90sec (In>32A)MCB will trip within times specified.5xIn: t<0.1secB-type MCB ensured to trip in less than 0.1sec via magnetic release.5xIn: 0.1sec<t<15sec (In<=32A)5xIn: 0.1sec<t<30sec (In>32A)MCB will trip within times specified.t = Tripping time10xIn: 0.1sec<t<4sec (In<=32A)10xIn: 0.1sec<t<8sec (In>32A)MCB will trip within times specified.20xIn: t<0.1secD-type MCB ensured to trip in less than 0.1sec via magnetic release.10xIn: t<0.1secC-type MCB ensured to trip in less than 0.1sec via magnetic release.• All MCBs have a ‘trip free mechanism’.• Positive contact status indication in accordance with IEE wiring regulations.• Tunnel design, touch proof and captive terminals.• Can be used as isolating switches.• Lockable in both ON and OFF state without affecting the ability of the trip mechanism to operate.STANDARDS: BSEN 60898OPERATING VOLTAGE: 230 / 400V a.c.OPERATING FREQUENCY: 50HzAMBIENT OPERATING TEMP.: -5°C to +40°CMAXIMUM TERMINAL TORQUE: 3Nm (2.5Nm advised) ENCLOSURE MATERIAL: Urea or V0 rated Polyamide (self extinguishing at 960°C)SUPPLY: Can be supplied from top or bottom.IP RATING: IP4X (front face) IP20 (terminals)DIELECTRIC VOLTAGE: 2500V a.c.INSULATION VOLTAGE: 500V a.c.CURVE INSTANTANEOUS TRIPPING RANGECIRCUIT APPLICATIONSB 3 - 5 Used in domestic situations where maximum sensitivity is required and very little equipment with high start-up current is connected.C 5 - 10 Suitable for commercial / industrial situations where close protection is not required and start up currents of devices can run upto 5 times rated current for a short period. Where many low voltage lights are used in a domestic situation then, due to the inrush currents of the transformers, C Curve MCBs may be required to avoid nuisance tripping.D 10 - 20 Suitable for industrial application where start-up currents may be up to 10 times rated current, for example protection for machines with electric motors fitted, welding units etc.2345678MINIATURE CIRCUIT BREAKERSMCB TRIPPING CURVES TERMINAL CAPACITIESRANGE OF MCBs CAPACITY MCBs 25mm2 (In and Out)RCBOs 25mm2 (In) ; 10mm2 (Out)RCDs (<100A) 35mm2 (In and Out)RANGE OF MCBs CAPACITY RCDs (100A) 50mm2 (In and Out)Isolators 35/50mm2 (In and Out)Earth and Neutral bars 25mm2 and 16mm2Technical Information

Page 25

25 | M2M2TECHNICAL INFORMATIONTable A: Recommended MCB current ratings for the protection of cables to single phase 230V a.c. motors.SWITCHGEAR DERATINGAdjacent MCBs, RCBOs or MCB/RCD combinations should not be continuously loaded at, or approaching, their normal rated currents when mounted in enclosures. It is also good engineering practice to make provisions for adequate free air between devices.Under these circumstances and, in common with other manufacturers, we recommend a diversity factor of 66% is applied to the MCB nominal rated current, especially if the MCB is expected to be loaded near to or at full rating for more than one hour.Thermal issues should also be taken into consideration when choosing conductor size for the protected circuits.MCB INSTALLATION CURRENTSGenerally the MCBs detailed are not intended to provide close overload protection for motors. However they can be employed in conjunction with the customary motor overload current device as an alternative to the isolator/fuse combination. In this condition the MCB will protect the cable to the motor and the motor will be protected by its own protective device.The tables A and B detailed below give recommendations on MCB selection for motor circuits, for C type only.Note: The values of full load current and starting current will approximately be 10% higher at 380/220V ac than the figures stated for 400/230V motors. The figures given in table A for the starting current and its duration are intended to be used as a guide only. In practice the motor run up time will depend upon the type of drive and the loading of the motor when it is started. Consultation with the motor manufacturer should give an indication of the magnitude of the starting current and the duration.The selection of the most suitable circuit breaker can then be found from the time/current characteristics of the circuit breaker.Technical InformationHORSE POWER (HP) POWER FLC STARTING CURRENT DURATION OF STARTING CURRENT MCB CURRENT RATING0.25 0.18 kW 1.5A 10.5A 3.0 sec 10A0.50 0.37 kW 3.0A 21.0A 3.0 sec 10A0.75 0.55 kW 5.0A 35.0A 3.0 sec 16A1.00 0.75 kW 5.5A 38.5A 3.1 sec 20A1.50 1.12 kW 8.5A 59.5A 3.15 sec 32A2.00 1.50 kW 10.5A 73.5A 3.2 sec 50A3.00 2.25 kW 15.5A 108.0A 3.3 sec 50A4.00 3.00 kW 20.0A 140.0A 3.4 sec 63A5.00 3.80 kW 24.0A 168.0A 3.5 sec -6.00 4.50 kW 28.0A 196.0A 3.6 sec -7.00 5.20 kW 32.0A 224.0A 3.7 sec -Maximum Earth fault loop impedance (ie Zs ohms) for circuits supplying socket outlets in accordance with BS7671 regulation 411.3.2 at 218.5V (230V x 0.95 Cmin).At these levels of earth loop impedance, MCBs will provide disconnection times in accordance with BS7671 for circuits supplying socket outlets .BS7671: 2008 requirements: Electrical installations (17th Edition of the IEE Wiring regulations) specifically identifies B and C Curve. Lower earth fault loop impedance’s (Zs) are generally necessary for D Curve to achieve the operating times required by regulation 413-02-08. (Maximum Zs is calculated using the formula in the regulations and the characteristics of the circuit breaker). Where the requirement can not be achieved, use of the circuit breakers as overcurrent protective devices is not precluded, but the use of residual current circuit breakers (RCDs) to provide protection against indirect earth fault condition is implied. Establishment of the value of the earth fault loop impedance (Zs) at the design stage of installation will determine which type of circuit breaker should be used.MCB INSTALLATION VOLTAGESB & C CURVE 1 POLE 230V ACDEVICE STANDARD 6A 10A 16A 20A 32A 40A 50A 63AType B BSEN 60898 7.43 4.46 2.79 2.23 1.39 1.11 0.89 0.71Type C BSEN 60898 3.83 2.30 1.44 1.15 0.72 0.58 0.46 0.37

Page 26

26M2 | TECHNICAL INFORMATIONTable B: Recommended MCB current ratings for the protection of cables to three phase 400V a.c. motors.Providing both overcurrent protection and earth leakage protection in a combined unit, M2 offers a range of RCBOs which will fit all M2 modular consumer units and B Curve 3-phase distribution boards.RCBOs are available in a range of current ratings from 6A to 45A and with short circuit capacities (Ics) from 4.5kA up to 10kA. RCBOs are offered in both B and C Curve tripping characteristics.All single module RCBOs contain a switched live and solid neutral where as the double module unit offers both Live and Neutral switching.GENERAL SPECIFICATIONSimilar to our MCB technology all devices have a ‘trip free mechanism’ and positive contact status indication. Connection of load circuit cables is via tunnel design cable clamps with touch proof and captive terminal screws. Lockable in both ON and OFF position without affecting the ability of the trip mechanism to operate.RCBOs allow earth fault protection to be restricted to individual circuits, thus ensuring that only the circuit with the fault is interrupted. (When groups of circuits are protected by an RCD, all circuits would be interrupted under a fault condition, which may cause unnecessary inconvenience).Technical InformationHORSE POWER (HP)POWER FLC STARTING CURRENTDURATION OF STARTING CURRENTMCB CURRENT RATINGSTARTING CURRENTDURATION OF STARTING CURRENTMCB CURRENT RATING0.25 0.18 0.5 3.5 3.0 6 1.75 9.0 60.50 0.37 0.9 6.3 3.0 6 3.15 9.1 60.75 0.55 1.3 9.1 3.0 6 4.59 9.2 61.00 0.75 1.9 13.3 3.1 6 6.6 9.3 61.50 1.12 2.5 17.5 3.15 10 8.7 9.5 102.00 1.50 3.4 23.8 3.2 10 11.9 9.6 103.00 2.25 4.8 33.6 3.3 16 16.8 10.0 164.00 3.00 6.4 44.8 3.4 20 22.4 10.3 205.00 3.80 7.8 54.6 3.5 20 27.3 10.7 206.00 4.50 9.0 63.0 3.6 20 31.5 11.0 207.00 5.20 10.3 72.1 3.7 32 36.0 11.3 207.50 5.60 11.6 81.2 3.75 32 40.6 11.5 3210.00 7.50 14.4 100.8 4.0 40 50.4 12.3 4012.50 9.30 17.3 121.1 4.25 40 60.5 13.2 4015.00 11.00 21.1 148.0 4.5 63 73.8 14.0 5020.00 15.00 28.0 196.0 5.0 63 93.0 15.7 6325.00 18.50 35.0 245.0 5.5 - 122.0 17.3 -7.00 5.20 32.0 224.0 3.7 -RCBOs STANDARDS: BSEN 61009OPERATING VOLTAGE: 230V a.c.EARTH LEAKAGE SENSITIVITY: 30mASWITCHING: Single pole - L (switched) + N (solid) Double pole - L + N (switched)OPERATING FREQUENCY: 50Hz AMBIENT OPERATING TEMP.: -5°C - +40°CMAXI. TERMINAL TORQUE: 2NmENCLOSURE MATERIAL: VO rated PBT (both self extinguishing at 960°C)SUPPLY CONNECTIONS: Consult specific product data sheetIP RATING: IP4X (front face); IP20 (terminals)DIELECTRIC VOLTAGE: 2500V a.c.INSULATION VOLTAGE: 500V a.c.

Page 27

27 | M2M2Type 1 SPDs are key to providing necessary protection of the installation against the effects of lightning strikes entering the building. Type 1 SPDs are designed to carry partial lightning currents and are defined as being tested with a high energy 10/350μs (Iimp) wave shape.These Type 1 SPDs must be installed on incoming services (e.g. mains power and data) when an external Lightning Protection System (LPS) is installed on a building. Where partial lightning currents can also flow due to a direct lightning strike on overhead supplies or externally mounted equipment, Type 1 SPDs should also be used. Combined Type 1 + Type 2 SPDs are installed at the origin of the supply to the building, normally within the main switchboard. If the installation being protected is already fitted with an SCPD of 250A or less then the SPD can be connected direct to the busbar otherwise ensure the device is adequately protected.Type 2 SPDs in this modular form offer more general surge protection for equipment within the installation from sources of problematic electrical surges internal to the building (typically switching transients). If the installation being protected is already fitted with an SCPD of 250A or less then the SPD can be connected direct to the busbar otherwise ensure the device is adequately protected. Their protection is limited by distance with a general protection zone of <10m. Equipment further away necessitate the installation of an additional Type 2 units in sub-distribution boards.Type 2 and Type 3 SPDs are designed to discharge the induced surges created by lightning electromagnetic fields and also other transient surge events such as switching surges, supply faults etc. These devices are defined as being tested with a specific energy wave shape of 8/20μs (In) for Type 2 SPDs or a combination wave shapes for Type 3 SPDs. For many applications where the requirement is to provide surge protection only, Type 2 and Type 3 SPDs play a critical role in protecting electronic equipment.Type 3 SPDs provide the primary ‘fine protection’ from surges, giving high sensitive equipment that added level of security. As a rule they should be installed as close as possible to the equipment being protected.TECHNICAL INFORMATIONGENERAL SPECIFICATIONRCDs M2 RCDs are available in a wide range of earth leakage sensitivities and current ratings to meet the majority of applications. Residual Current Devices (RCDs) come in both 2 pole and 4 pole options.M2 RCDs incorporate the latest in electronic earth leakage detection technology ensuring consistent reliable performance. With sufficient contact gap, switching of all Live and Neutral conductors and positive contact indication in accordance with the IEE wiring regulation these devices can be used for isolation purposes.RCDs also incorporate ‘trip free mechanism’ technology and can be locked ON or OFF with suitable locking device (eg.DLPX1) without affecting the devices ability to offer protection under fault conditions.General use RCDs for domestic single phase or light commercial three phase systems are required to be either Type AC or Type A. This type reference defines the nature of the earth leakage which the RCD is expected to detect and protect against.Type AC: Tripping is ensured for residual sinusoidal alternating currents, whether suddenly applied or slowly rising.Identified by the symbol: Type A: Tripping is ensured for residual sinusoidal alternating currents and residual pulsating direct currents, whether suddenly applied or slowly rising.Identified by the symbol: SURGE PROTECTION DEVICESTechnical InformationSTANDARDS: BSEN 61008 OPERATING VOLTAGE: 2P-230V a.c. 4P-230/400V a.c.OPERATING FREQUENCY: 50HzAMBIENT OPERATING TEMP.: -5°C - +40°CMAXI. TERMINAL TORQUE: 2.5Nm ENCLOSURE MATERIAL: VO rated polyamide or PBT (both self extinguishing at 960°C)SUPPLY CONNECTIONS: Consult specific product data sheetIP RATING: IP4X (front face); IP20 (terminals)DIELECTRIC VOLTAGE: 2500V a.c.INSULATION VOLTAGE: 500V a.c.

Page 28

Page 29

ELECTRICAL WIRINGACCESSORIES M2 wiring accessories, both stylish and practical for the modern home or commercial office. Suitable to replace traditional products but equally at home in contemporary settings. Modular design enables the installer to provide solutions to suit exact customer requirements with maximum flexibility. Small details of providing screw head fixing covers and flushed in neons to enable easy cleaning separate the M2 range from others in the category. Added to the full range of voice, data and media products M2 presents a comprehensive range for the modern living and the working environment.Section Contentslimline 28square 40grid 46 metal 54weatherproof 58decorative 62decorative screwless 74ceiling 86Technical Information 88®29

Page 30

30M2 | SLIMLINE FEATURESSlimline25 YEAR GUARANTEEDeveloped through rigorous product testing and designed for the contemporary installation – M2 slimline wiring accessories. Featuring new products to enhance the user experience such as, faster charging USB sockets and the brand new M2 grid range to offer endless flexibility. Ideal for the domestic and commercial application M2 slimline has been launched with the future in mind, for both product and packaging. Our polybags and cardboard inner cartons are made from recycled content and we encourage you to recycle them after use.KEYFEATURES:M2 SLIMLINE RANGE WIRING ACCESSORIESFEATURES:RECYCLED PACKAGINGThe packaging has been carefully selected throughout the development stages of this range to ensure we minimise our impact on the environment. Both the polybag and the inner cardboard carton are manufactured from recycled content and after use can now be recycled.

Page 31

31 | M2M2SLIMLINE FEATURESSlimlineHIGH GLOSS CURVED PROFILEANTIMICROBIAL PROPERTIESFAST CHARGING USB SOCKETSPLEASE RECYCLEMADE FROM RECYCLED MATERIALLDPE BAG & CARTONFULLY TESTED & CERTIFIEDCOMPLIMENTED BY THE M2 GRID RANGEHIGH GLOSS CURVED PROFILEManufactured from urea formaldehyde with antimicrobial properties in a stylish high gloss curved profile. Fully tested & certified & supplied with screw cap covers to maximise the overall aesthetics once installed.GRID & EURO MODULESComplimented by a range of grid, euro, switch modules & plates for ultimate flexibility.NEW!

Page 32

32M2 | Slimline10AX SWITCHESMeasurements:Millimetres (mm) unless stated otherwiseSurface mount box:19 mmFlush mount box: 16 mm1010-003DESCRIPTION CAT. NO. H W1 Gang 1 way light switch 1010-001 86 861 Gang 2 way light switch 1010-002 86 862 Gang 2 way light switch 1010-003 86 863 Gang 2 way light switch 1010-004 86 8610AX LIGHT SWITCHES2 WAY1010-005DESCRIPTION CAT. NO. H W 4 Gang 2 way light switch 1010-005 86 1466 Gang 2 way light switch 1010-006 86 14610AX LIGHT SWITCHESDESCRIPTION CAT. NO. H W 1 Gang intermediate switch 1010-007 86 8610A INTERMEDIATE SWITCHDESCRIPTION CAT. NO. H W 1 Gang 2 way retractive switch 1010-008 86 8610A RETRACTIVE SWITCH

Page 33

33 | M2M2Slimline10AX SWITCHES & DIMMERS1010-011DESCRIPTION CAT. NO. H W10A TP fan isolator 1010-011 86 8610A TP swicth 1010-012 86 86TRIPLE POLE SWITCHESDESCRIPTION CAT. NO. H W 10A Key card switch 1010-013 86 8610A KEY CARD SWITCHFlush mount box depth: 25 mm Surface mount box depth: 29 mm.1010-022DESCRIPTION WATT CAT. NO. H W 1 Gang leading edge dimmer 40-400W (3-150W) 1010-021 86 862 Gang leading edge dimmer 40-400W (3-150W) 1010-022 86 863 Gang leading edge dimmer 40-400W (3-150W) 1010-023 86 1464 Gang leading edge dimmer 40-400W (3-150W) 1010-024 86 146INTELLIGENT DIMMERSFlush mount box depth: 25mm Surface mount box depth: 29mm.1010-223DESCRIPTION CAT. NO. H W 1 Gang unfurnished kits 1010-221 86 862 Gang unfurnished kits 1010-222 86 863 Gang unfurnished kits 1010-223 86 1464 Gang unfurnished kits 1010-224 86 146UNFURNISHED DIMMER KITSFlush mount box depth: 25 mm Surface mount box depth: 29 mm.1010-026DESCRIPTION WATT CAT. NO. H W 1 Gang intelligent dimmer 40-400W (5-150W) 1010-025 86 862 Gang intelligent dimmer 40-400W (5-150W) 1010-026 86 863 Gang intelligent dimmer 40-400W (5-150W) 1010-027 86 1464 Gang intelligent dimmer 40-400W (5-150W) 1010-028 86 146LEADING EDGE LED DIMMERSMeasurements:Millimetres (mm) unless stated otherwise1010-057ELDESCRIPTION CAT. NO. H W20A DP 1010-057 86 8620A DP printed ‘EMG LTG TEST’1010-057EL86 8620A DP KEY SWITCHES

Page 34

34M2 | SlimlineSOCKET OUTLETSMeasurements:Millimetres (mm) unless stated otherwiseSurface mount box: 29mm Flush mount box: 25mm1010-104DESCRIPTION CAT. NO. H W 13A 2 Gang switched - SP 1010-104 86 14613A 2 Gang switched - DP 1010-105 86 146SWITCHED SOCKETSDESCRIPTION CAT. NO. H W 13A Switched RCD socket 1010-120 86 146RCD PROTECTED1010-103DESCRIPTION CAT. NO. H W 13A 1 Gang switched - SP 1010-102 86 8613A 1 Gang switched - DP 1010-103 86 86SWITCHED SOCKETS30mAPASSIVEDESCRIPTION CAT. NO. H W 13A 2 Gang unswitched 1010-101 86 146UNSWITCHED SOCKETDESCRIPTION CAT. NO. H W 13A 1 Gang unswitched 1010-100 86 86UNSWITCHED SOCKETDESCRIPTION CAT. NO. H W5A 1 Gang 1010-109 86 865A UNSWITCHED SOCKET5A

Page 35

35 | M2M2SlimlineSOCKET OUTLETSMeasurements:Millimetres (mm) unless stated otherwiseSurface mount box: 29mm Flush mount box: 25mm1010-914QC 30WPD 33WTYPE A&CTYPE A2XDESCRIPTION CAT. NO. H W 13A 2 Gang 3.1A Type A USB 1010-914 86 14613A 2 Gang 4.8A Type A USB 1010-915 86 146USB SWITCHED SOCKET OUTLETS1010-904DESCRIPTION CAT. NO. H W 13A 1 Gang 2.1A Type A&C USB 1010-902 86 8613A 2 Gang 3.1A Type A&C USB 1010-904 86 146USB SWITCHED SOCKET OUTLETSDESCRIPTION CAT. NO. H W 13A 2 Gang Dual USB Type A&C QC 30W/PD 33W USB1010-916 86 146USB SWITCHED SOCKET OUTLETSTYPE A&C13A 2 Gang Switched Socket + Dual USB Type A&C Charger OutletsDUALVOLTAGESurface mount box: 47mm Flush mount box: 47mmSHAVER OUTLETDESCRIPTION CAT. NO. H W Dual voltage 20VA 230V / 115V 1010-110 146 86KEY LOCKABLEDESCRIPTION CAT. NO. H W 13A DP neon 1010-121 86 146KEY LOCKABLE SOCKET

Page 36

36M2 | SlimlineCONNECTION UNITSMeasurements:Millimetres (mm) unless stated otherwiseSurface mount box: 29mm Flush mount box: 25mmUNSWITCHED FUSED SPURDESCRIPTION CAT. NO. H W 13A Unswitched spur 1010-040 86 8613A Unswitched spur flex outlet 1010-042 86 86UNSWITCHED FUSED SPUR NEONDESCRIPTION CAT. NO. H W 13A Unswitched spur neon 1010-041 86 8613A Unswitched spur neon flex outlet1010-043 86 861010-046DESCRIPTION CAT. NO. H W 13A Spur 1010-044 86 8613A Spur flex outlet1010-046 86 86SWITCHED FUSED SPURDESCRIPTION CAT. NO. H W 13A Unswitched RCD socket1010-049 86 86RCD PROTECTED SPUR1010-045DESCRIPTION CAT. NO. H W 13A Spur neon 1010-045 86 8613A Spur neon flex outlet1010-047 86 86SWITCHED FUSED SPUR NEON1010-0401010-043DESCRIPTION CAT. NO. H W 20A Flex outlet 1010-055 86 86FLEX OUTLETDESCRIPTION CAT. NO. H W 20A DP Key lockable switch 1010-060 86 86KEY LOCKABLE SWITCHKEY LOCKABLE30mA Passive

Page 37

37 | M2M2Slimline20A & 45A SWITCH & SOCKETSMeasurements:Millimetres (mm) unless stated otherwiseSurface mount box: 29mm Flush mount box: 25mmDESCRIPTION CAT. NO. H W 20A DP switch 1010-050 86 8620A DP SWITCHDESCRIPTION CAT. NO. H W 20A DP switch neon1010-051 86 8620A DP SWITCH NEON1010-201DESCRIPTION CAT. NO. H W 45A DP switch 1010-200 86 8645A DP switch neon1010-201 86 861 GANG DP SWITCHESRED ROCKER1010-202DESCRIPTION CAT. NO. H W 45A DP switch 1010-202 146 8645A DP switch neon1010-203 146 862 GANG DP SWITCHESRED ROCKER1010-205DESCRIPTION CAT. NO. H W 45A DP switch 1010-204 86 14645A DP switch neon1010-205 86 146COOKER CONTROL UNITSRED ROCKER1010-401DESCRIPTION CAT. NO. H W 45A DP switch 1010-400 86 8645A DP switch neon1010-401 86 861 GANG DP SWITCHES1010-402DESCRIPTION CAT. NO. H W 45A DP switch 1010-402 146 8645A DP switch neon1010-403 146 86WHITE ROCKER2 GANG DP SWITCHESWHITE ROCKERWHITE ROCKER1010-405DESCRIPTION CAT. NO. H W 45A DP switch 1010-404 86 14645A DP switch neon1010-405 86 146COOKER CONTROL UNITSDESCRIPTION CAT. NO. H W 45A Cooker connection unit1010-210 86 146COOKER CONNECTION UNIT

Page 38

38M2 | SlimlineCOAXIAL, VOICE & DATAMeasurements:Millimetres (mm) unless stated otherwiseSurface mount box: 29mm Flush mount box: 25mmCAT. NO. H W 1010-300 86 86COAXIALCAT. NO. H W 1010-301 86 86TWIN COAXCAT. NO. H W 1010-302 86 86SATELLITECAT. NO. H W 1010-303 86 86COAXIAL/SATELLITECAT. NO. H W 1010-304 86 86MASTER TELEPHONECAT. NO. H W 1010-305 86 86SECONDARY TELEPHONECAT. NO. H W 1010-306 86 86DATA CAT 5ECAT. NO. H W 1010-307 86 86TWIN DATA CAT 5ECAT. NO. H W 1010-308 86 86DATA CAT 6CAT. NO. H W 1010-309 86 86TWIN DATA CAT 6CAT. NO. H W 1010-310 86 86RJ11CAT. NO. H W 1010-312 86 86ISOLATED COAX

Page 39

39 | M2M2SlimlinePATTRESSES & PLATESMeasurements:Millimetres (mm) unless stated otherwiseSurface mount box: 29mm Flush mount box: 25mmFor grid & euro modules please see page 22For switch modules please see page 14CAT. NO. H W D1010-070 86 86 161010-071 86 86 251010-072 86 86 351010-073 86 86 471 GANG PATTRESS BOXESCAT. NO. H W D1010-074 86 146 251010-075 86 146 351010-076 86 146 471010-077 Dual Box 86 173 252 GANG PATTRESS BOXESBLANK PLATESDESCRIPTION CAT. NO. H W 1 Gang 1010-030 86 862 Gang 1010-031 86 146EURO MOD PLATESDESCRIPTION CAT. NO. H W 1G 1 module 1010-320 86 861G 2 module 1010-321 86 862G 4 module 1010-322 86 1461010-3201010-0301 & 2 GANG GRID PLATES3 & 4 GANG GRID PLATES 6 & 8 GANG GRID PLATES 9 & 12 GANG GRID PLATES1010-0741010-0701010-3511010-353 1010-355 1010-356Grid frame sold separately: 3011-360 Grid frame sold separately: 3011-360Grid frame sold separately: 3011-360Grid frame sold separately: 3011-359APERTURE PLATESDESCRIPTION CAT. NO. H W 1G 1 aperture 1010-080 86 861G 2 aperture 1010-081 86 861G 3 aperture 1010-082 86 862G 4 aperture 1010-084 86 1462G 6 aperture 1010-085 86 1461010-080Suitable for M2 switch modules.Suitable for M2 euro modules.DESCRIPTION CAT. NO. H W 1G 1 grid mod 1010-350 86 861G 2 grid mods 1010-351 86 86DESCRIPTION CAT. NO. H W 2G 3 grid mod 1010-352 86 1462G 4 grid mods 1010-353 86 146DESCRIPTION CAT. NO. H W 6 grid mod 1010-354 146 1468 grid mods 1010-355 146 146DESCRIPTION CAT. NO. H W 9 grid mod 1010-356 206 14612 grid mods 1010-357 206 146

Page 40

40M2 | 13A DP SWITCHESPRINTED CAT. NO.- 1011-050Boiler 1011-050BLDish Washer 1011-050DWCooker Hood 1011-050CHFan 1011-050FNFridge Freezer 1011-050FFFridge 1011-050FDFreezer 1011-050FZHeater 1011-050HRHob 1011-050HBHob Ignition 1011-050HIHot Tap 1011-050HTLights 1011-050LTMicrowave 1011-050MWOven 1011-050OVTumble Dryer 1011-050TDWaste Disposal 1011-050WDWater Heater 1011-050WHWine Cooler 1011-050WCWarming Drawer 1011-050WRWashing Machine 1011-050WM1011-050DW1011-050HT1011-050WR1011-050CH1011-050HR1011-050WCDESCRIPTION CAT. NO. H W D10A 1 Way 1011-001 60 16 251 WAY LIGHT SWITCH2 WAY LIGHT SWITCHDESCRIPTION CAT. NO. H W D10A 2 Way 1011-002 60 16 25INTERMEDIATE SWITCHDESCRIPTION CAT. NO. H W D10A Intermediate 1011-007 60 16 25RETRACTIVE SWITCHDESCRIPTION CAT. NO. H W D10A 2 Way 1011-008 60 16 252 WAY KEY SWITCHDESCRIPTION CAT. NO. H W D10A DP 1011-058 60 16 221 WAY KEY SWITCHESDESCRIPTION CAT. NO. H W D10A DP 1011-057 60 16 2210A EMG LTG 1011-057EL 60 16 221011-0581011-057ELSWITCH MODULESMeasurements:Millimetres (mm) unless stated otherwiseSlimline

Page 41

41 | M2M2NOTESSlimline

Page 42

42M2 | SquareSquareSQUARE FEATURESA comprehensive & competitive range of square edged white moulded wiring accessories for the domestic, retail & commercial sectors. Modular construction light switches allow ‘on site flexibility’. Matching modular plates to extend the range to include International power, Data & Media.KEYFEATURES:M2 SQUARE RANGE WIRING ACCESSORIESFEATURES:25 YEAR GUARANTEERECYCLED PACKAGINGThe packaging has been carefully selected throughout the development stages of this range to ensure we minimise our impact on the environment. Both the polybag and the inner cardboard carton are manufactured from recycled content and after use can now be recycled.

Page 43

43 | M2M2SquareSquareSQUARE FEATURESOFFERING A COMPREHENSIVE RANGE1.Remove Screw From Desired Module3.Slot Intermediate Module into Position & Fix2.Remove ModuleMaterial• Thermoset Urea faceplates• Traditional square edge• High gloss finish• Flat fronted to ensure correct plug seatingHigh impact resistant• Designed to be resilient• Scratch resistant• Guaranteed to stand the test of timeSwitches• Easy switch action• Modular format for greater flexibility• Colour matched rocker switches on 45A rangePower indication • Neon indicators available• Crescent rocker markingNEON INDICATORS MODULAR SWITCHESDUAL EARTHModular design of• 1 - way• 2 - way• Intermediateswitches allow for on site flexibility.

Page 44

44M2 | 2010-0031 WAY LIGHT SWITCH2 WAY LIGHT SWITCHESINTERMEDIATE LIGHT SWITCH 6A TRIPLE POLE SWITCHESFlush mount box depth: 25mm Surface mount box depth: 29mm.Surface mount box: 19mm.RETRACTIVE SWITCHLIGHT SWITCHES• Traditional square edge face plate and rocker• Switch modules interchangeable• Compliant to relevant British Standards• Ideal for domestic/commercial useA Comprehensive & Competitive Range of Square Edged White Moulded Wiring Accessories. DESCRIPTION CAT. NO. H W1 Gang 2010-002 86 862 Gang 2010-003 86 863 Gang 2010-004 86 864 Gang 2010-005 86 1466 Gang 2010-006 86 146DESCRIPTION CAT. NO. H W1 Gang 2010-001 86 86DESCRIPTION CAT. NO.H W 1 Gang 2010-007 86 86DESCRIPTION CAT. NO.H W 6A TP switch fan isolator2010-011 86 866A TP switch 2010-012 86 86SquareMeasurements:Millimetres (mm) unless stated otherwiseFlush mount box: 16mm, unless stated otherwiseWHITEMOULDED16mmBACK BOX2010-0122010-022DESCRIPTION CAT. NO. H W 1 Gang 2010-021 86 862 Gang 2010-022 86 863 Gang 2010-023 86 1464 Gang 2010-024 86 146TRAILING EDGE LED DIMMERS2010-222DESCRIPTION CAT. NO. H W 1 Gang 2010-221 86 862 Gang 2010-222 86 863 Gang 2010-223 86 1464 Gang 2010-224 86 14640-400W (5-150W)UNFURNISHED DIMMER KITS1010-025DESCRIPTION CAT. NO. H W 1 Gang 2010-025 86 86LEADING EDGE LED DIMMERS40-400W (3-150W)DESCRIPTION CAT. NO.H W 6A 1 gang 2010-008 86 86

Page 45

45 | M2M22010-100UNSWITCHED SOCKET OUTLETSSWITCHED SOCKET OUTLETS2010-104DUAL SHAVER SOCKET OUTLETFlush mount box depth: 47mm Surface mount box depth: 47mm.USB SWITCHED SOCKET OUTLETSFlush mount box depth: 35mm. Surface mount box depth: 29mm.13A Single & Double Pole Switched Socket White• Switches centrally positioned• Traditional square edge face plate• Dual earth terminalsSOCKET OUTLETSDESCRIPTION CAT. NO. H W13A 1 Gang switched socket - SP 2010-102 86 8613A 2 Gang switched socket - SP 2010-104 86 14613A 2 Gang switched socket - DP 2010-105 86 146DESCRIPTION CAT. NO. H W13A 1 Gang switched socket 2.1A 2010-912 86 8613A 2 Gang switched socket 3.1A 2010-914 86 146CHARGESHARED3.1ADUALVOLTAGESquareMeasurements:Millimetres (mm) unless stated otherwiseSurface mount box: 29mm Flush mount box: 25mmDESCRIPTION CAT. NO. H W13A 1 Gang socket outlet 2010-100 86 8613A 2 Gang socket outlet 2010-101 86 1465A 1 Gang socket outlet 2010-109 86 86TYPE A USBDUALPORTUSB SWITCHED SOCKET OUTLETMount box depth: 35mm.DESCRIPTION CAT. NO. H W13A 2 Gang switched socket outlet 2010-904 86 146CHARGESHARED3.1ATYPE A & TYPE CDUALPORTDESCRIPTION CAT. NO. H W Shaver Socket 2010-110 146 862010-112CONTRACT SOCKET OUTLETDESCRIPTION CAT. NO. H W13A 2 Gang socket outlet 2010-112 86 146SINGLEPOLE2010-914

Page 46

46M2 | 45A DOUBLE POLE SWITCHESDOUBLE POLE SWITCHES & CONNECTION UNITS2010-20113A FUSED CONNECTION UNITSBottom edge flex outlet complete with clamps and 13A cartridge fuse to BS 1362 as standard.20A SWITCHES2010-051Bottom edge flex outlet complete with clamps.2010-046COOKER PANELS2010-204Flush mount box depth: 47mm Surface mount box depth: 47mm.SquareMeasurements:Millimetres (mm) unless stated otherwiseSurface mount box: 29mmFlush mount box: 25mmDESCRIPTION CAT. NO. H W45A Cooker control unit 2010-204 86 14645A Cooker control unit neon 2010-205 86 14645A cooker connection unit 2010-210 86 86DESCRIPTION CAT. NO. H W1 Gang 45A switch 2010-200 86 861 Gang 45A switch c/w neon 2010-201 86 862 Gang 45A switch 2010-202 146 862 Gang 45A switch c/w neon 2010-203 146 86DESCRIPTION CAT. NO. H W20A DP switch 2010-050 86 8620A DP switch neon 2010-051 86 8620A Flex outlet plate 2010-055 86 8620A Sink/bath switch 2010-056 86 86DESCRIPTION CAT. NO. H W13A Unswitched 2010-042 86 8613A Unswitched neon 2010-043 86 8613A Switched 2010-046 86 8613A Switched neon 2010-047 86 86

Page 47

47 | M2M2COAXIAL & SATELLITEFlush mount box depth: 25mm | Surface mount box depth: 29mm.2010-030BLANK PLATES2010-300COAXIAL, TELEPHONE & BLANK PLATESSquareMeasurements:Millimetres (mm) unless stated otherwiseSurface mount box: 29mmFlush mount box: 25mmFor euro modules please see page 28DESCRIPTION CAT. NO. H W1 Gang 2010-030 86 862 Gang 2010-031 86 146RJ11 SOCKETDESCRIPTION CAT. NO. H W1 Gang RJ11 2010-310 86 86DESCRIPTION CAT. NO. H W1 Gang coax 2010-300 86 861 Gang satellite 2010-302 86 86Coax & satellite 2010-303 86 86EURO MOD PLATESTELEPHONE SOCKETS2010-300DESCRIPTION CAT. NO. H WMaster 2010-304 86 86Secondary 2010-305 86 86Flush mount box depth: 25mm Surface mount box depth: 29 mm.2010-322DESCRIPTION CAT. NO. H W2G 4 modules 2010-322 86 146CAT. NO. H W D2010-070 86 86 162010-071 86 86 252010-072 86 86 352010-073 86 86 471 GANG PATTRESS BOXESCAT. NO. H W D2010-074 86 146 252010-075 86 146 352010-076 86 146 472 GANG PATTRESS BOXES2 GANG DUAL PATTRESS BOXCAT. NO. H W D2010-077 86 146 252010-0762010-070Suitable for M2 euro modules.EURO MOD PLATES2010-321DESCRIPTION CAT. NO. H W1G 1 module 2010-320 86 861G 2 modules 2010-321 86 86Suitable for M2 euro modules.

Page 48

48M2 | Grid• Fixed locations for modules• Up to 12 gang• Full range of modules available• 20A Rated modules• New products addedUP TO 12 GANGFace plates available from 1-12 gang to enable multiple switching applications.25 YEAR GUARANTEEA traditional grid system incorporating mounting frames, modular face plates and modules. Face plates available from 1-12 gang to enable multiple switching applications. A full range of modules are available for both commercial & domestic applications in the M2 slimline and metal ranges. KEYFEATURES:M2 GRID RANGE WIRING ACCESSORIESFEATURES:RECYCLED PACKAGINGThe packaging has been carefully selected throughout the development stages of this range to ensure we minimise our impact on the environment. Both the polybag and the inner cardboard carton are manufactured from recycled content and after use can now be recycled.GRID FEATURES

Page 49

49 | M2M2GridDESCRIPTION CAT. NO. H W D1 & 2 Gang 3011-359 68 80 14GRID FRAMEStandard: BS 5733.Standard: BS 5733.DESCRIPTION CAT. NO. H W D3 & 4 Gang 3011-360 68 140 14GRID FRAMESUITABLE FOR:1 Gang size faceplates for 1 and 2 modulesSUITABLE FOR:2 Gang & larger size faceplates for 3, 4, 6, 8, 9 & 12 modulesDESCRIPTION CAT. NO. H W D6 & 8 Gang back box 3011-361 132 132 47GRID FLUSH BACK BOXDESCRIPTION CAT. NO. H W D9 & 12 Gang back box 3011-362 192 132 47GRID FLUSH BACK BOX3 0 3 00 5 1N /AWhite012Brushed Stainless3MetalFINISH CODEN /AWhite012BlackINSERT CODEPRODUCT CODERANGE CODE3 0grid®GRID MODULE PRODUCT CODE LOGICslimline3 0 1 1decorativescrewless3 0 3 03 0 1 1metalGRID FEATURES

Page 50

50M2 | GridDESCRIPTION CAT. NO. H W D1 Way 3011-001 55 25 292 Way 3011-002 55 25 29LIGHT SWITCHES3 POSITIONDESCRIPTION CAT. NO. H W D3 Position 3011-009 55 25 293 POSITION RETRACTIVEDESCRIPTION CAT. NO. H W D3 Position 3011-010 55 25 29INTERMEDIATEDESCRIPTION CAT. NO. H W DIntermediate 3011-007 55 25 29RETRACTIVEDESCRIPTION CAT. NO. H W D2 Way 3011-008 55 25 291 Way 3011-014 55 25 29FAN ISOLATORDESCRIPTION CAT. NO. H W DTP Fan isolator 3011-011 55 25 29DESCRIPTION CAT. NO. H W DLED 3011-021 60 25 50Intelligent 3011-025 60 25 50DIMMER SWITCHESDESCRIPTION CAT. NO. H W D6A 2 way 3011-029 55 25 55SWITCH MODULEBLANKDESCRIPTION CAT. NO. H W DBlank 3011-030 55 25 263011-0013011-025RETRACTIVEDESCRIPTION CAT. NO. H W DPrinted PRESS 3011-008PR 55 25 29Printed bell icon 3011-008BE 55 25 29NEON INDICATORSDESCRIPTION CAT. NO. H W DAmber 3011-015 55 25 29Green 3011-016 55 25 29Red 3011-017 55 25 293011-008DESCRIPTION CAT. NO. H W DKit 3011-221 55 25 55UNFURNISHED DIMMER KIT3011-0173011-008PRGRID MODULES SLIMLINE & METALMeasurements:Millimetres (mm) unless stated otherwiseSupplied with:Slimline & metal trim white

Page 51

51 | M2M2Grid20A DP SWITCHESPRINTED CAT. NO.- 3011-050Boiler 3011-050BLDish Washer 3011-050DWCooker Hood 3011-050CHFan 3011-050FNFridge Freezer 3011-050FFFridge 3011-050FDFreezer 3011-050FZHeater 3011-050HRHob 3011-050HBHob Ignition 3011-050HIHot Tap 3011-050HTLights 3011-050LTMicrowave 3011-050MWOven 3011-050OVTumble Dryer 3011-050TDWaste Disposal 3011-050WDWater Heater 3011-050WHWine Cooler 3011-050WCWarming Drawer 3011-050WRWashing Machine 3011-050WM3011-050DW3011-050HT3011-050WR20A DP NEON SWITCHESPRINTED CAT. NO.- 3011-051Boiler 3011-051BLDish Washer 3011-051DWCooker Hood 3011-051CHFan 3011-051FNFridge Freezer 3011-051FFFridge 3011-051FDFreezer 3011-051FZHeater 3011-051HRHob 3011-051HBHob Ignition 3011-051HIHot Tap 3011-051HTLights 3011-051LTMicrowave 3011-051MWOven 3011-051OVTumble Dryer 3011-051TDWaste Disposal 3011-051WDWater Heater 3011-051WHWine Cooler 3011-051WCWarming Drawer 3011-051WRWashing Machine 3011-051WM3011-051CH3011-051HR3011-051WCKEY SWITCHESDESCRIPTION CAT. NO. H W D20A DP 3011-057 55 25 25Printed ‘EMG LTG TEST’ 3011-057EL 55 25 25FUSE & FLEX MODULEDESCRIPTION CAT. NO. H W D13A Fuse 3011-040 55 25 2520A Flex outlet 3011-055 53 25 163011-058DP RETRACTIVEDESCRIPTION CAT. NO. H W DPush to make 3011-059 55 25 29KEY SWITCHESDESCRIPTION CAT. NO. H W D2 Way 3011-058 55 25 25Printed ‘EMG LTG TEST’ 3011-058EL 55 25 253011-0583011-040GRID MODULES SLIMLINE & METALMeasurements:Millimetres (mm) unless stated otherwiseSupplied with:Slimline & metal trim white

Page 52

52M2 | GridDESCRIPTION CAT. NO. H W D1 Way 3030-001 55 25 292 Way 3030-002 55 25 29LIGHT SWITCHES3 POSITIONDESCRIPTION CAT. NO. H W D3 Position 3030-009 55 25 293 POSITION RETRACTIVEDESCRIPTION CAT. NO. H W D3 Position 3030-010 55 25 29INTERMEDIATEDESCRIPTION CAT. NO. H W DIntermediate 3030-007 55 25 29RETRACTIVEDESCRIPTION CAT. NO. H W D2 Way 3030-008 55 25 291 Way 3030-014 55 25 29FAN ISOLATORDESCRIPTION CAT. NO. H W DTP Fan isolator 3030-011 55 25 29DESCRIPTION CAT. NO. H W DLED 3030-021 60 25 50Intelligent 3030-025 60 25 50DIMMER SWITCHESDESCRIPTION CAT. NO. H W D6A 2 way 3030-029 55 25 55SWITCH MODULEBLANKDESCRIPTION CAT. NO. H W DBlank 3030-030 55 25 263030-0013030-025RETRACTIVEDESCRIPTION CAT. NO. H W DPrinted PRESS 3030-008PR 55 25 29Printed bell icon 3030-008BE 55 25 29NEON INDICATORSDESCRIPTION CAT. NO. H W DAmber 3030-015 55 25 29Green 3030-016 55 25 29Red 3030-017 55 25 293030-008DESCRIPTION CAT. NO. H W DKit 3030-221 55 25 55UNFURNISHED DIMMER KIT3011-0173030-008PRGRID MODULES DECORATIVE SCREWLESSMeasurements:Millimetres (mm) unless stated otherwiseSupplied with:Black & white trim3030-009

Page 53

53 | M2M2Grid20A DP SWITCHESPRINTED CAT. NO.- 3030-050Boiler 3030-050BLDish Washer 3030-050DWCooker Hood 3030-050CHFan 3030-050FNFridge Freezer 3030-050FFFridge 3030-050FDFreezer 3030-050FZHeater 3030-050HRHob 3030-050HBHob Ignition 3030-050HIHot Tap 3030-050HTLights 3030-050LTMicrowave 3030-050MWOven 3030-050OVTumble Dryer 3030-050TDWaste Disposal 3030-050WDWater Heater 3030-050WHWine Cooler 3030-050WCWarming Drawer 3030-050WRWashing Machine 3030-050WM3030-050DW3030-050HT3030-050WR20A DP NEON SWITCHESPRINTED CAT. NO.- 3030-051Boiler 3030-051BLDish Washer 3030-051DWCooker Hood 3030-051CHFan 3030-051FNFridge Freezer 3030-051FFFridge 3030-051FDFreezer 3030-051FZHeater 3030-051HRHob 3030-051HBHob Ignition 3030-051HIHot Tap 3030-051HTLights 3030-051LTMicrowave 3030-051MWOven 3030-051OVTumble Dryer 3030-051TDWaste Disposal 3030-051WDWater Heater 3030-051WHWine Cooler 3030-051WCWarming Drawer 3030-051WRWashing Machine 3030-051WM3030-051CH3030-051HR3030-051WCKEY SWITCHESDESCRIPTION CAT. NO. H W D20A DP 3030-057 55 25 25Printed ‘EMG LTG TEST’ 3030-057EL 55 25 25FUSE & FLEX MODULEDESCRIPTION CAT. NO. H W D13A Fuse 3030-040 55 25 2520A Flex outlet 3030-055 53 25 163011-057ELDP RETRACTIVEDESCRIPTION CAT. NO. H W DPush to make 3030-059 55 25 29KEY SWITCHESDESCRIPTION CAT. NO. H W D2 Way 3030-058 55 25 25Printed ‘EMG LTG TEST’ 3030-058EL 55 25 253030-0583030-040GRID MODULES DECORATIVE SCREWLESSMeasurements:Millimetres (mm) unless stated otherwiseSupplied with:Black & white trim

Page 54

54M2 | GridDESCRIPTION CAT. NO.10A 3210-013KEY CARD SWITCHDESCRIPTION CAT. NO.13A 50x50 3210-1005A 50x50 3210-109UK SOCKETS3210-100DESCRIPTION CAT. NO.16A 50x50 3210-106EURO SOCKETDESCRIPTION CAT. NO.2.1mA 50x50 3210-902USB Mounted socket3210-346USB TYPE ADESCRIPTION CAT. NO.3.1mA 25x50 3210-9133.6mA 50x50 3210-904QC 18W/PD 45W 50x503210-916USB TYPE A+C3210-9023210-904DESCRIPTION CAT. NO.TV 25x50 3210-300Radio 25x50 3210-331TV/Radio 50x50 3210-332TV/Sat 50x50 3210-333PCB TV 25x50 3210-336TVSATELLITEDESCRIPTION CAT. NO.HDMI mounted socket3210-345HDMIDESCRIPTION CAT. NO.Triplex 50x50 3210-334Quad 50x50 3210-3353210-335DESCRIPTION CAT. NO.Master 25x50 3210-304Secondary 25x50 3210-305TELEPHONE SOCKETS3210-304DESCRIPTION CAT. NO.RJ11 25x50 3210-3103210-333DESCRIPTION CAT. NO.Cat 5E 25x50 3210-306Cat 6 25x50 3210-308Cat 6A 25x50 3210-311DATA 3210-311DESCRIPTION CAT. NO.Frame 25x50 3210-338Cat 5E 25x50 3210-339Cat 6 25x50 3210-340ANGLED DATA3210-340DESCRIPTION CAT. NO.Quarter 12.5x50 3210-032Half 25x50 3210-030BLANKS 3210-030DESCRIPTION CAT. NO.Half 25x50 3210-341Full 50x50 3210-342Double 100x50 3210-343BRUSH 3210-3423210-345EURO MODULESMeasurements:Millimetres (mm) unless stated otherwiseDIGITAL SOCKETSDATADESCRIPTION CAT. NO.Satellite 25x50 3210-330Terminal F 25x50 3210-3373210-330

Page 55

55 | M2M2GridDESCRIPTION CAT. NO.10A 3280-013KEY CARD SWITCHDESCRIPTION CAT. NO.13A 50x50 3280-1005A 50x50 3280-109UK SOCKETS3280-109DESCRIPTION CAT. NO.16A 50x50 3280-106EURO SOCKETDESCRIPTION CAT. NO.2.1mA 50x50 3280-902USB Mounted socket3280-346USB TYPE ADESCRIPTION CAT. NO.3.1mA 25x50 3280-9133.6mA 50x50 3280-904QC 18W/PD 45W 50x503280-916USB TYPE A+C3280-3463280-913DESCRIPTION CAT. NO.TV 25x50 3280-300Radio 25x50 3280-331TV/Radio 50x50 3280-332TV/Sat 50x50 3280-333PCB TV 25x50 3280-336TVDESCRIPTION CAT. NO.HDMI mounted socket3280-345HDMIDESCRIPTION CAT. NO.Triplex 50x50 3280-334Quad 50x50 3280-3353280-334DESCRIPTION CAT. NO.Master 25x50 3280-304Secondary 25x50 3280-305TELEPHONE SOCKETS3280-3053280-332DESCRIPTION CAT. NO.Cat 5E 25x50 3280-306Cat 6 25x50 3280-308Cat 6A 25x50 3280-311DATA 3280-308DESCRIPTION CAT. NO.Frame 25x50 3280-338Cat 5E 25x50 3280-339Cat 6 25x50 3280-340ANGLED DATA3280-338DESCRIPTION CAT. NO.Quarter 12.5x50 3280-032Half 25x50 3280-030BLANKS 3280-032DESCRIPTION CAT. NO.Half 25x50 3280-341Full 50x50 3280-342Double 100x50 3280-343BRUSH 3280-3433280-345EURO MODULESMeasurements:Millimetres (mm) unless stated otherwiseDIGITAL SOCKETSDESCRIPTION CAT. NO.RJ11 25x50 3280-310DATADESCRIPTION CAT. NO.Satellite 25x50 3280-330Terminal F 25x50 3280-3373280-330SATELLITE

Page 56

56M2 | METAL FEATURESM2 metal offers a comprehensive range of robust surface mount accessories for the domestic and commercial markets. With the introduction of our grid range the scope for applications is virtually endless. An ideal solution where a more durable accessory is needed: domestic garages, workshops and sheds or commercial warehouses, stores and factories.KEYFEATURES:M2 METALWIRING ACCESSORIESFEATURES:MetalRECYCLED PACKAGINGThe packaging has been carefully selected throughout the development stages of this range to ensure we minimise our impact on the environment. The inner cardboard cartons and product boxes are manufactured from recycled content and after use can now be recycled. 25 YEAR GUARANTEE

Page 57

57 | M2M2METAL FEATURESOFFERING A COMPREHENSIVE RANGEMetalROBUST & DURABLE STEEL ENCLOSURE20mm KNOCKOUTS FAST CHARGING USB SOCKETSGRID & EURO MODULESNEW!

Page 58

58M2 | SWITCHES & SOCKETSMetalMeasurements:Millimetres (mm) unless stated otherwiseMetalclad depth:42mm4021-004DESCRIPTION CAT. NO. H W 1 Gang 2 way 4021-002 80 802 Gang 2 way 4021-003 80 803 Gang 2 way 4021-004 80 804 Gang 2 way 4021-005 80 140LIGHT SWITCHES4021-051DESCRIPTION CAT. NO. H W 20A DP switch 4021-050 80 8020A DP switch neon4021-051 80 8020A DP SWITCHES4021-203DESCRIPTION CAT. NO. H W 45A DP switch 4021-202 140 8045A DP switch neon4021-203 140 8045A DP SWITCHES4021-103DESCRIPTION CAT. NO. H W 1 Gang - SP 4021-102 80 801 Gang - DP 4021-103 80 802 Gang - DP 4021-105 80 1401 Gang neon 4021-107 80 802 Gang neon 4021-108 80 14013A SWITCHED SOCKETS4021-101DESCRIPTION CAT. NO. H W 1 Gang 4021-100 80 802 Gang 4021-101 80 14013A UNSWITCHED SOCKETSDESCRIPTION CAT. NO. H W Switched 4021-120 80 14013A RCD PROTECTED30mAPASSIVE4021-040DESCRIPTION CAT. NO. H W Spur 4021-040 80 80Neon 4021-041 80 80Flex outlet 4021-042 80 80Neon flex outlet 4021-043 80 8013A UNSWITCHED FUSED SPURS4021-047DESCRIPTION CAT. NO. H W Spur 4021-044 80 80Neon 4021-045 80 80Flex outlet 4021-046 80 80Neon flex outlet 4021-047 80 8013A SWITCHED FUSED SPURSKEY LOCKABLEDESCRIPTION CAT. NO. H W 20A DP Key lock-able switch 4021-060 80 80KEY LOCKABLE SWITCH

Page 59

59 | M2M2MetalDESCRIPTION CAT. NO. H W Switched 4021-049 80 8013A RCD PROTECTED SPUR30mAPASSIVE4021-904DESCRIPTION CAT. NO. H W 1G 2.1A Type A 4021-912 80 802G 3.1A Type A 4021-914 80 1402G 3.1A Type A+C 4021-904 80 14013A USB SWITCHED SOCKET OUTLETS4021-031DESCRIPTION CAT. NO. H W 1 Gang 4021-030 80 802 Gang 4021-031 80 140BLANK PLATES4021-321DESCRIPTION CAT. NO. H W 1G 1 module 4021-320 80 801G 2 modules 4021-321 80 802G 4 modules 4021-322 80 140EURO MOD PLATES4020-353DESCRIPTION CAT. NO. H W 1 Gang 4020-350 80 802 Gang 4020-351 80 80 3 Gang 4020-352 80 140 4 Gang 4020-353 80 140 GRID PLATES4020-355DESCRIPTION CAT. NO. H W 6 Gang 4020-354 140 1408 Gang 4020-355 140 140 9 Gang 4020-356 202 14012 Gang 4020-357 202 140 GRID PLATESMeasurements:Millimetres (mm) unless stated otherwiseMetalclad depth:42mmFor grid & euro modules please see page 22FUSED SPURS & PLATES4020-368DESCRIPTION CAT. NO. H W D1 Gang 4020-367 76 76 402 Gang 4020-368 76 136 401 Gang 4020-363 76 76 502 Gang 4020-364 76 136 50BACK BOXES4020-365BACK BOXESDESCRIPTION CAT. NO. H W D6 & 8 Gang 4020-365 136 136 409 & 12 Gang 4020-366 198 136 40Grid frame sold separately: 3011-360Grid frame sold separately: 1 & 2 gang 3011-359, 3 & 4 gang 3011-360KEY LOCKABLEDESCRIPTION CAT. NO. H W 13A DP Key lock-able socket neon4021-121 86 146KEY LOCKABLE SOCKET

Page 60

60M2 | WEATHERPROOF FEATURESM2 weatherproof offers a comprehensive range of robust surface mount accessories design for the outdoors. Compliant to IP66 the range provides protection against jets of water from any direction and small dust particles. The switches are 20A rated and new additions to the range include RCD sockets and spurs for added protection.KEYFEATURES:M2 WEATHERPROOFWIRING ACCESSORIESFEATURES:WeatherproofRECYCLED PACKAGINGThe packaging has been carefully selected throughout the development stages of this range to ensure we minimise our impact on the environment. The inner cardboard cartons and product boxes are manufactured from recycled content and after use can now be recycled. We have also reduced the amount of singe use plastics used by removing this from plastic window.25 YEAR GUARANTEE

Page 61

61 | M2M2WEATHERPROOF FEATURESOFFERING A COMPREHENSIVE RANGEWeatherproofIP66 RATED ROBUST POLYCARBONATE CONSTRUCTIONTRANSLUCENT & SOLID GREY COVERSPAD LOCKABLE COVERS• Permanently on, for dark environments• On when switch is off, seek light• Power on indicatorNEON OPTIONS:20A WEATHERPROOF SWITCHES

Page 62

62M2 | WEATHERPROOF SWITCHESLIGHT SWITCHESRETRACTIVE SWITCHWeatherproofMeasurements:Millimetres (mm) unless stated otherwise1 GANG LIGHT SWITCHDESCRIPTION CAT. NO. H W1 Gang light switch 2 way 5090-002 90 9020A 1 Gang 2 Way Weatherproof Light Switch • 20A switch rating• IP66 protection from strong jets of water from any direction• Protection from dust and small particles• Optional neon provided• Robust polycarbonate construction• 20mm knockouts on all sides• Two knockouts on one sideIP66 RATEDIP66 RATEDDESCRIPTION CAT. NO.H W2 Gang 2 way 5090-003 90 90IP66 RATEDDOUBLE POLE SWITCHIP66 RATEDDESCRIPTION CAT. NO.H W20A Retractive 5090-008 90 90DESCRIPTION CAT. NO.H W20A DP switch 5090-051 90 90

Page 63

63 | M2M2WEATHERPROOF ENCLOSURES5090-5022 GANG SOCKET OUTLETS5090-104ENCLOSURES5090-161WeatherproofMeasurements:Millimetres (mm) unless stated otherwiseDESCRIPTION CAT. NO. H W1 Gang 5090-160 135 1021 Gang (grey lid) 5090-560 135 1022 Gang 5090-161 135 1622 Gang (grey lid) 5090-561 135 162DESCRIPTION CAT. NO. H W13A 2 Gang switch socket outlet 5090-104 135 16213A 2 Gang switch socket outlet (grey lid) 5090-504 135 1622 Gang Weatherproof 13A Switched Socket• IP66 protection from strong jets of water from any direction as well as protection from dust and small particles• Robust polycarbonate construction• Translucent & solid grey cover• Temperature tolerant • 20mm knockouts on all sides• Two knockouts on one sideIP66 RATED1 GANG SWITCHED FUSE CONNECTION UNITS5090-544DESCRIPTION CAT. NO. H W13A Switched 5090-044 135 10213A Switched (grey lid)5090-544 135 102DESCRIPTION CAT. NO. H W13A Socket outlet5090-102 135 10213A socket outlet (grey lid)5090-502 135 1021 GANG SOCKET OUTLETS1 GANG UNSWITCHED FUSE CONNECTION UNITS5090-040DESCRIPTION CAT. NO. H W13A Unswitched 5090-040 135 10213A Unswitched (grey lid)5090-540 135 1022 GANG RCD PROTECTED SOCKETS5090-120DESCRIPTION CAT. NO. H W13A RCD DP 5090-120 135 16213A RCD DP (grey lid)5090-520 135 1621 GANG RCD PROTECTED CONNECTION UNITS 5090-549DESCRIPTION CAT. NO. H W13A Unswitched 5090-049 135 10213A Unswitched (grey lid)5090-549 135 1025090-504

Page 64

64M2 | DECORATIVE FEATURESDecorativeM2 Decorative creates a world of functionality and choice with beautiful aesthetic finishes. Five distinctive plate finishes: antique and polished brass; brushed and polished stainless steel and black nickel. A variety of modules KEYFEATURES:M2 DECORATIVE RANGE WIRING ACCESSORIESFEATURES:can be selected to suit individual requirements.Easy to install, a pleasure to use… the only difficulty is making your choice !25 YEAR GUARANTEE

Page 65

65 | M2M2PRODUCT SELECTIONWhen ordering any of the M2 Decorative range, replace ‘#’ in the catalogue number with your desired plate finish code above.For example - 6031-105. AB & BN not available with white insert.DecorativePRODUCT CODE GUIDEDESCRIPTION PRODUCT CODE1 Gang 1 way light switch 0011 Gang 2 way light switch 0022 Gang 2 way light switch 0033 Gang 2 way light switch 0044 Gang 2 way light switch 0056 Gang 2 way light switch 0061 Gang intermediate switch 007Retractive switch 0086A Triple pole fan isolator 0116A Triple pole switch 01210A Key switch 013LIGHT SWITCHESDESCRIPTION PRODUCT CODE1 Gang 13A unswitched 1002 Gang 13A unswitched 1011 Gang 13A switched SP 1021 Gang 13A switched DP 1032 Gang 13A switched SP 1042 Gang 13A switched DP 1055A Socket 109Shaver socket 1102 Gang contract socket 1122 Gang RCD socket DP 120SOCKET OUTLETS6 0 3 110 5RANGE CODEPRODUCT CODEPRODUCT CODE LOGIC6031 - 1052 GANG 13A SWITCHED SOCKET OUTLET DP6 0decorativeBrushed StainlessAntique BronzeBlackNickel34567Polished StainlessPolished BrassFINISH CODEN/AWhite012BlackINSERT CODE##PRINT LEGENDRelates to print legend on grid modules. Refer to main product brochure for options.##

Page 66

66M2 | DESCRIPTION CAT. NO. H W1 Gang switch metal rocker white insert 60#1-002 86 861 Gang switch metal rocker black insert 60#2-002 86 86DecorativeDESCRIPTION CAT. NO. H WSwitch metal rocker white insert 60#1-004 86 86Switch metal rocker black insert 60#2-004 86 86DESCRIPTION CAT. NO. H WSwitch metal rocker white insert 60#1-003 86 86Switch metal rocker black insert 60#2-003 86 86SWITCHES2 WAY LIGHT SWITCHES10A 1 Gang 2 Way Light Switch Available in all Five Decorative Finishes• 5mm Shallow Plate• 10AX rated• Two way switches• Protective lacquer coating2 GANG 2 WAY LIGHT SWITCHES3 GANG 2 WAY LIGHT SWITCHES6052-0046062-003PLATEFINISHES5 25mmBACK BOXMeasurements:Millimetres (mm) unless stated otherwiseFlush mount box: 25mm6030: Brushed Stainless Steel6040: Polished Stainless Steel6050: Polished Brass6060: Antique Brass6070: Black Nickel25 YEAR GUARANTEE

Page 67

67 | M2M2DESCRIPTION CAT. NO. H WMetal rocker white insert 60#1-005 86 146Metal rocker black insert 60#2-005 86 146DESCRIPTION CAT. NO. H W1 Gang switch metal rocker white insert 60#1-011 86 861 Gang switch metal rocker black insert 60#2-011 86 86DESCRIPTION CAT. NO. H WMetal rocker white insert 60#1-006 86 146Metal rocker black insert 60#2-006 86 146DESCRIPTION CAT. NO. H WMetal rocker white insert 60#1-007 86 86Metal rocker black insert 60#2-007 86 86DESCRIPTION CAT. NO. H WMetal rocker white insert 60#1-008 86 86Metal rocker black insert 60#2-008 86 86SWITCHES6042-0076032-0082 WAY 4 GANG LIGHT SWITCHES6072-0056051-006INTERMEDIATE LIGHT SWITCHES2 WAY RETRACTIVE SWITCHESTRIPLE POLE SWITCHES6062-01110A Triple Pole Fan Isolator Available in all Five Decorative Finishes• 5mm Shallow Plate• 10AX rated• Protective lacquer coatingPLATEFINISHES5 25mmBACK BOXDecorativeMeasurements:Millimetres (mm)unless stated otherwiseFlush mount box: 25 mm6030: Brushed Stainless Steel6040: Polished Stainless Steel6050: Polished Brass6060: Antique Brass6070: Black Nickel2 WAY 6 GANG LIGHT SWITCHES25 YEAR GUARANTEE

Page 68

68M2 | 6030-0226070-027DecorativeDIMMER SWITCHESMeasurements:Millimetres (mm) unless stated otherwiseFlush mount box:29mm6030: Brushed Stainless Steel6040: Polished Stainless Steel6050: Polished Brass6060: Antique Brass6070: Black NickelFlush mount box depth: 25mm Surface mount box depth: 29mm.DESCRIPTION WATT CAT. NO. H W 1 Gang leading edge dimmer 400W 60#0-021 86 862 Gang leading edge dimmer 400W 60#0-022 86 863 Gang leading edge dimmer 400W 60#0-023 86 146LED DIMMERSFlush mount box depth: 25mm Surface mount box depth: 29mm.DESCRIPTION CAT. NO. H W 1 Gang unfurnished kits 60#0-221 86 862 Gang unfurnished kits 60#0-222 86 863 Gang unfurnished kits 60#0-223 86 1464 Gang unfurnished kits 60#0-224 86 146UNFURNISHED DIMMER KITSFlush mount box depth: 25mm Surface mount box depth: 29mm.DESCRIPTION WATT CAT. NO. H W 1 Gang LED dimmer 9-150W 60#0-025 86 862 Gang LED dimmer 9-150W 60#0-026 86 863 Gang LED dimmer 9-150W 60#0-027 86 1464 Gang LED dimmer 9-150W 60#0-028 86 146STANDARD LEADING EDGE DIMMERS6040-224

Page 69

69 | M2M213A UNSWITCHED FUSED CONNECTION UNITS13A SWITCHED FUSED CONNECTION UNITSWITH FLEX OUTLETDESCRIPTION CAT. NO. H WMetal cover white insert 60#1-040 86 86Metal cover black insert 60#2-040 86 86Neon metal cover white insert 60#1-041 86 86Neon metal cover black insert 60#2-041 86 86DESCRIPTION CAT. NO. H WMetal rocker white insert 60#1-044 86 86Metal rocker black insert 60#2-044 86 86Neon metal rocker white insert 60#1-045 86 86Neon metal rocker black insert 60#2-045 86 86DESCRIPTION CAT. NO. H WFlex outlet metal cover white insert 60#1-046 86 86Flex outlet metal cover black insert 60#2-046 86 86Neon flex outlet metal cover white insert 60#1-047 86 86Neon flex outlet metal cover black insert 60#2-047 86 8613A SWITCHED FUSED CONNECTION UNITSDESCRIPTION CAT. NO. H WFlex outlet metal cover white insert 60#1-042 86 86Flex outlet metal cover black insert 60#2-042 86 86Neon flex outlet metal cover white insert 60#1-043 86 86Neon flex outlet metal cover black insert 60#2-043 86 8613A UNSWITCHED FUSED CONNECTION UNITSWITH FLEX OUTLETDecorativeFUSED CONNECTION UNITSSWITCHED FUSED CONNECTION UNITS6072-0406032-0466041-0436051-045Measurements:Millimetres (mm)unless stated otherwiseFlush mount box: 25 mm6030: Brushed Stainless Steel6040: Polished Stainless Steel6050: Polished Brass6060: Antique Brass6070: Black NickelUNSWITCHED FUSED CONNECTION UNITS

Page 70

70M2 | DecorativeMeasurements:Millimetres (mm) unless stated otherwise6030: Brushed Stainless Steel6040: Polished Stainless Steel6050: Polished Brass6060: Antique Brass6070: Black Nickel1 GANG USB SWITCHED SOCKET OUTLETSDESCRIPTION CAT. NO. H WMetal rocker white insert 60#1-912 86 86Metal rocker black insert 60#2-912 86 866062-9121 GANG DP SWITCHED SOCKET OUTLETSDESCRIPTION CAT. NO. H WMetal rocker white insert 60#1-103 86 86Metal rocker black insert 60#2-103 86 866042-1036031-105Flush mount box: 25mm.DESCRIPTION CAT. NO. H WMetal rocker white insert 60#1-105 86 146Metal rocker black insert 60#2-105 86 146DESCRIPTION CAT. NO. H W5A White insert 60#1-109 86 865A Black insert 60#2-109 86 865A 1 GANG UNSWITCHED SOCKET OUTLETS 6072-109Flush mount box: 35 mm.Flush mount box: 25mm.Flush mount box: 25mm.TYPE A2.1A2 GANG USB SWITCHED SOCKET OUTLETSDESCRIPTION CAT. NO. H WMetal rocker white insert 60#1-904 86 146Metal rocker black insert 60#2-904 86 1466031-904Flush mount box: 35 mm.TYPE A+C3.1A2 GANG USB SWITCHED SOCKET OUTLETSDESCRIPTION CAT. NO. H WMetal rocker white insert 60#1-914 86 146Metal rocker black insert 60#2-914 86 146Flush mount box: 35 mm.TYPE A3.1A2 GANG DP SWITCHED SOCKET OUTLETS6031-914SOCKET OUTLETS

Page 71

71 | M2M2Decorative20A DP FLEX OUTLETS20A DP SWITCHESFlush mount box: 25mm.DESCRIPTION CAT. NO. H WMetal rocker white insert 60#1-050 86 86Metal rocker black insert 60#2-050 86 866051-050DESCRIPTION CAT. NO. H WFlex outlet white insert 60#1-055 86 86Flex outlet black insert 60#2-055 86 866051-0556041-110DUAL VOLTAGE SHAVER SOCKETSFlush mount box: 47mm.DESCRIPTION CAT. NO. H WDual voltage shaver socket white insert 60#1-110 146 86Dual voltage shaver socket black insert 60#2-110 146 8620A DP SWITCHES NEONDESCRIPTION CAT. NO. H WMetal rocker white insert 60#1-051 86 86Metal rocker black insert 60#2-051 86 866072-05120A DP SWITCHES FLEX OUTLETDESCRIPTION CAT. NO. H WMetal rocker white insert 60#1-052 86 86Metal rocker black insert 60#2-052 86 866062-052Flush mount box: 25mm.Flush mount box: 25mm.20A DP SWITCHES NEON & FLEX OUTLETDESCRIPTION CAT. NO. H WMetal rocker white insert 60#1-053 86 86Metal rocker black insert 60#2-053 86 866031-053Flush mount box: 25mm.SHAVER SOCKETS & 20A SWITCHESMeasurements:Millimetres (mm)unless stated otherwise6030: Brushed Stainless Steel6040: Polished Stainless Steel6050: Polished Brass6060: Antique Brass6070: Black Nickel20A DP SINK/BATH SWITCHESDESCRIPTION CAT. NO. H WWhite insert 60#1-056 86 86Black insert 60#2-056 86 866031-056

Page 72

72M2 | DOUBLE POLE SWITCHES & COOKER PANELSDecorativeMeasurements:Millimetres (mm) unless stated otherwiseFlush mount box: 47mm6030: Brushed Stainless Steel6040: Polished Stainless Steel6050: Polished Brass6060: Antique Brass6070: Black Nickel6032-2056051-204DESCRIPTION CAT. NO. H WMetal rocker white insert 60#1-202 146 86Metal rocker black insert 60#2-202 146 862 GANG 45A VERTICAL DP SWITCHES6041-202DESCRIPTION CAT. NO. H WMetal rockers white insert 60#1-204 86 146Metal rockers black insert 60#2-204 86 146COOKER CONTROL UNITCOOKER CONTROL UNIT NEONDESCRIPTION CAT. NO. H WMetal rocker white insert 60#1-203 146 86Metal rocker black insert 60#2-203 146 862 GANG 45A VERTICAL DP SWITCHES NEON6062-203DESCRIPTION CAT. NO. H WMetal rockers white insert 60#1-205 86 146Metal rockers black insert 60#2-205 86 1466072-2001 GANG 45A DP SWITCHESDESCRIPTION CAT. NO. H WMetal rocker white insert 60#1-201 86 86Metal rocker black insert 60#2-201 86 86DESCRIPTION CAT. NO. H WMetal rocker white insert 60#1-200 86 86Metal rocker black insert 60#2-200 86 861 GANG 45A DP SWITCHES NEON6032-201

Page 73

73 | M2M2OUTLETS & PLATESDecorativeMeasurements:Millimetres (mm)unless stated otherwiseFlush Mount Box: 25mm6030: Brushed Stainless Steel6040: Polished Stainless Steel6050: Polished Brass6060: Antique Brass6070: Black NickelDESCRIPTION CAT. NO. H WWhite insert 60#1-300 86 86Black insert 60#2-300 86 861 GANG COAXIAL OUTLETS6062-3001 GANG COAXIAL ISOLATED OUTLETS6072-3111 GANG SATELLITE OUTLETS6031-3021 GANG COAXIAL & SATELLITE OUTLETS6051-3032 GANG COAXIAL OUTLETS6042-3011 GANG TELEPHONE MASTER OUTLETS6062-3041 GANG TELEPHONE SECONDARY OUTLETS6072-305 1 GANG RJ11 OUTLETS6051-3101 GANG CAT5E DATA OUTLETS6032-306BLANK PLATESDESCRIPTION CAT. NO. H WWhite insert 60#1-301 86 86Black insert 60#2-301 86 86DESCRIPTION CAT. NO. H WWhite insert 60#1-302 86 86Black insert 60#2-302 86 86DESCRIPTION CAT. NO. H WWhite insert 60#1-303 86 86Black insert 60#2-303 86 86DESCRIPTION CAT. NO. H WWhite insert 60#1-304 86 86Black insert 60#2-304 86 86DESCRIPTION CAT. NO. H WWhite insert 60#1-305 86 86Black insert 6532-305 86 86DESCRIPTION CAT. NO. H WWhite insert 60#1-306 86 86Black insert 60#2-306 86 86DESCRIPTION CAT. NO. H WWhite insert 60#1-310 86 86Black insert 60#2-310 86 86DESCRIPTION CAT. NO. H WWhite insert 60#1-312 86 86Black insert 60#2-312 86 86DESCRIPTION CAT. NO. H W1 Gang 60#0-030 86 862 gang 60#0-031 86 1466060-030

Page 74

74M2 | EURO MODULE PLATESDecorativeMeasurements:Millimetres (mm) unless stated otherwise6030: Brushed Stainless Steel6040: Polished Stainless Steel6050: Polished Brass6060: Antique Brass6070: Black NickelDESCRIPTION CAT. NO. H W2 Gang euro mod plate white trim 60#1-322 86 1462 Gang euro mod plate black trim 60#2-322 86 1464 MODULE EURO MOD PLATES6051-3221 MODULE EURO MOD PLATESDESCRIPTION CAT. NO. H W1 Module euro mod plate white trim 60#1-320 86 861 Module euro mod plate black trim 60#2-320 86 862 MODULE EURO MOD PLATESDESCRIPTION CAT. NO. H W2 Module euro mod plate white trim 60#1-321 86 862 Module euro mod plate black trim 60#2-321 86 866062-3206072-321

Page 75

75 | M2M2DecorativeMeasurements:Millimetres (mm) unless stated otherwiseFor euro modules please see page 28DESCRIPTION CAT. NO. H W3 Module aperture plate white trim 60#1-082 86 863 Module aperture plate black trim 60#2-082 86 863 MODULE APERTURE PLATES6062-0821 MODULE APERTURE PLATESDESCRIPTION CAT. NO. H W1 Module aperture plate white trim 60#1-080 86 861 Module aperture plate black trim 60#2-080 86 862 MODULE APERTURE PLATESDESCRIPTION CAT. NO. H W2 Module aperture plate white trim 60#1-081 86 862 Module aperture plate black trim 60#2-081 86 866051-0806032-081DESCRIPTION CAT. NO. H W4 Module aperture plate white trim 60#1-084 86 1464 Module aperture plate black trim 60#2-084 86 1464 MODULE APERTURE PLATES6072-084DESCRIPTION CAT. NO. H W6 Module aperture plate white trim 60#1-085 86 1466 Module aperture plate black trim 60#2-085 86 1466 MODULE APERTURE PLATES6051-085SWITCH MODULE PLATES

Page 76

76M2 | DECORATIVE SCREWLESS FEATURESThe 4.5mm slim profile plates also have a lacquer coating that avoids the unsightly finger marks. The accessories will fit standard depth wall boxes and are therefore suitable for the majority of refurbishments or new build applications.With all the switches, dimmers and sockets that you would expect M2 Decorative Screwless is further complemented by the M2 Grid range with plates from 1 to 12 gang and a comprehensive range of grid modules.KEYFEATURES:M2 DECORATIVE SCREWLESSWIRING ACCESSORIESFEATURES:• Simple clip on design• 4.5mm modern slim profile• Suitable for retrofitting• Protective lacquer coating• 25 year guaranteeDecorative ScrewlessRECYCLED PACKAGINGThe packaging has been carefully selected throughout the development stages of this range to ensure we minimise our impact on the environment. The inner cardboard cartons and product boxes are manufactured from recycled content and after use can now be recycled. We have also reduced the amount of singe use plastics used by removing this from plastic window.25 YEAR GUARANTEE

Page 77

77 | M2M2DECORATIVE SCREWLESS FEATURESOFFERING A COMPREHENSIVE RANGEGasketHigh quality, robust plastic gasket.InsertsAvailable with white or black inserts.Face PlateBrushed stainless steel with a protective lacquer and supplied with a film cover.3.1.2.Decorative ScrewlessMATCHING METAL ROCKERSBRUSHED STAINLESS STEELSIMPLE TO UNCLIP FACE PLATESFULLY TESTED & CERTIFIED

Page 78

78M2 | DESCRIPTION CAT. NO. H W1 Gang switch metal rocker white insert 6531-002 86 861 Gang switch metal rocker black insert 6532-002 86 86Decorative ScrewlessDESCRIPTION CAT. NO. H WSwitch metal rocker white insert 6531-004 86 86Switch metal rocker black insert 6532-004 86 86DESCRIPTION CAT. NO. H WSwitch metal rocker white insert 6531-003 86 86Switch metal rocker black insert 6532-003 86 86SWITCHES1 GANG 2 WAY LIGHT SWITCHES10AX 1 Gang 2 Way Light Switch Brushed Stainless Steel• Screwless face plate• Modern slim profile• Simple clip on face plate• 10AX rated• Matching brushed stainless steel switch• Black or white insert• Protective lacquer coating2 GANG 2 WAY LIGHT SWITCHES3 GANG 2 WAY LIGHT SWITCHES6531-004CLIP ONMeasurements:Millimetres (mm) unless stated otherwiseFlush mount box: 16mm6531-0026532-00310AX 2 Gang 2 Way Light Switch Brushed Stainless Steel10AX 3 Gang 2 Way Light Switch Brushed Stainless SteelSCREWLESSFACE PLATESIMPLE25 YEAR GUARANTEE

Page 79

79 | M2M2SWITCHES6531-0086532-0074 GANG 2 WAY LIGHT SWITCHES6531-006INTERMEDIATE LIGHT SWITCHES 2 WAY TRIPLE POLE SWITCHESDecorative ScrewlessMeasurements:Millimetres (mm) unless stated otherwiseFlush mount box: 16mm6532-005DESCRIPTION CAT. NO. H WMetal rocker white insert 6531-005 86 146Metal rocker black insert 6532-005 86 1466 GANG 2 WAY LIGHT SWITCHESDESCRIPTION CAT. NO. H WMetal rocker white insert 6531-006 86 146Metal rocker black insert 6532-006 86 146DESCRIPTION CAT. NO.H W 10A White insert 6531-007 86 8610A Black insert 6532-007 86 86RETRACTIVE SWITCHES 2 WAY6532-01110AX 4 Gang 2 Way Light Switch Brushed Stainless Steel10AX 6 Gang 2 Way Light Switch Brushed Stainless Steel6532-013KEY CARD SWITCHES32A 1 GangBack box depth: 45mm.DESCRIPTION CAT. NO. H WKey card switch metal rocker white insert 6531-013 86 86Key card switch metal rocker black insert 6532-013 86 86• Accepts standard 54mm wide cards• Incorporates seek light LED• 30 Second exit delay• 32A Rated• Black or white insert• Protective lacquer coatingRATED32ADESCRIPTION CAT. NO.H W 10A White insert 6531-008 86 8610A Black insert 6532-008 86 86DESCRIPTION CAT. NO.H W 10A White insert 6531-011 86 8610A Black insert 6532-011 86 86

Page 80

80M2 | Decorative ScrewlessDIMMER SWITCHESMeasurements:Millimetres (mm) unless stated otherwiseFlush mount box:25mm6530-0216530-027Flush mount box depth: 25mm Surface mount box depth: 29mm.DESCRIPTION WATT CAT. NO. H W 1 Gang leading edge dimmer 40-400W (3-100W) 6530-021 86 862 Gang leading edge dimmer 40-400W (3-100W) 6530-022 86 863 Gang leading edge dimmer 40-400W (3-100W) 6530-023 86 1464 Gang leading edge dimmer 40-400W (3-100W) 6530-024 86 146INTELLIGENT DIMMERSFlush mount box depth: 25mm Surface mount box depth: 29mm.DESCRIPTION CAT. NO. H W 1 Gang unfurnished kits 6530-221 86 862 Gang unfurnished kits 6530-222 86 863 Gang unfurnished kits 6530-223 86 1464 Gang unfurnished kits 6530-224 86 146UNFURNISHED DIMMER KITSFlush mount box depth: 25mm Surface mount box depth: 29mm.DESCRIPTION CAT. NO. H W 1 Gang intelligent dimmer 6530-025 86 862 Gang intelligent dimmer 6530-026 86 863 Gang intelligent dimmer 6530-027 86 1464 Gang intelligent dimmer 6530-028 86 146LEADING EDGE LED DIMMERS6530-221

Page 81

81 | M2M2Decorative ScrewlessMeasurements:Millimetres (mm) unless stated otherwiseFlush mount box: 25mmFUSED CONNECTION UNITS13A UNSWITCHED FUSED CONNECTION UNITS13A SWITCHED FUSED CONNECTION UNITSWITH FLEX OUTLET6531-0456532-046DESCRIPTION CAT. NO. H WMetal cover white insert 6531-040 86 86Metal cover black insert 6532-040 86 86Neon metal cover white insert 6531-041 86 86Neon metal cover black insert 6532-041 86 86DESCRIPTION CAT. NO. H WMetal rocker white insert 6531-044 86 86Metal rocker black insert 6532-044 86 86Neon metal rocker white insert 6531-045 86 86Neon metal rocker black insert 6532-045 86 86DESCRIPTION CAT. NO. H WFlex outlet metal cover white insert 6531-046 86 86Flex outlet metal cover black insert 6532-046 86 86Neon flex outlet metal cover white insert 6531-047 86 86Neon flex outlet metal cover black insert 6532-047 86 8613A SWITCHED FUSED CONNECTION UNITSDESCRIPTION CAT. NO. H WFlex outlet metal cover white insert 6531-042 86 86Flex outlet metal cover black insert 6532-042 86 86Neon flex outlet metal cover white insert 6531-043 86 86Neon flex outlet metal cover black insert 6532-043 86 866531-0406532-04313A UNSWITCHED FUSED CONNECTION UNITSWITH FLEX OUTLET

Page 82

82M2 | SOCKET OUTLETSDecorative ScrewlessMeasurements:Millimetres (mm) unless stated otherwise1 GANG USB SWITCHED SOCKET OUTLETSDESCRIPTION CAT. NO. H WMetal rocker white insert 6531-912 86 86Metal rocker black insert 6532-912 86 866531-9121 GANG DP SWITCHED SOCKET OUTLETSDESCRIPTION CAT. NO. H WMetal rocker white insert 6531-103 86 86Metal rocker black insert 6532-103 86 866532-1036531-105Flush mount box: 25mm.DESCRIPTION CAT. NO. H WMetal rocker white insert 6531-105 86 146Metal rocker black insert 6532-105 86 146DESCRIPTION CAT. NO. H W5A White insert 6531-109 86 865A Black insert 6532-109 86 865A 1 GANG UNSWITCHED SOCKET OUTLETS 6531-109Flush mount box: 35 mm.Flush mount box: 25mm.Flush mount box: 25mm.TYPE A2.1A2 GANG USB SWITCHED SOCKET OUTLETSDESCRIPTION CAT. NO. H WMetal rocker white insert 6531-904 86 146Metal rocker black insert 6532-904 86 1466531-904Flush mount box: 35 mm.TYPE A+C3.1A2 GANG USB SWITCHED SOCKET OUTLETSDESCRIPTION CAT. NO. H WMetal rocker white insert 6531-914 86 146Metal rocker black insert 6532-914 86 1466532-914Flush mount box: 35 mm.TYPE A3.1A2 GANG DP SWITCHED SOCKET OUTLETS2 GANG USB SWITCHED SOCKET OUTLETSDESCRIPTION CAT. NO. H WMetal rocker white insert 6531-917 86 146Metal rocker black insert 6532-917 86 1466531-917Flush mount box: 35 mm.TYPE A+C4.8ADESCRIPTION CAT. NO. H WMetal rocker white insert 6531-902 86 86Metal rocker black insert 6532-902 86 861 GANG USB SWITCHED SOCKET OUTLETS6531-902Flush mount box: 35mm.TYPE A+C2.1A

Page 83

83 | M2M2SHAVER SOCKETS & 20A SWITCHES20A DOUBLE POLE FLEX OUTLETSMeasurements:Millimetres (mm) unless stated otherwise20A DP SWITCHESFlush mount box: 25mm.DESCRIPTION CAT. NO. H WMetal rocker white insert 6531-050 86 86Metal rocker black insert 6532-050 86 866531-050DESCRIPTION CAT. NO. H WFlex outlet white insert 6531-055 86 86Flex outlet black insert 6532-055 86 866531-0556532-110DUAL VOLTAGE SHAVER SOCKETSFlush mount box: 47mm.DESCRIPTION CAT. NO. H WShaver socket white insert 6531-110 146 86Shaver socket black insert 6532-110 146 8620A DP SWITCHES NEONDESCRIPTION CAT. NO. H WMetal rocker white insert 6531-051 86 86Metal rocker black insert 6532-051 86 866532-05120A DP SWITCHES FLEX OUTLETDESCRIPTION CAT. NO. H WMetal rocker white insert 6531-052 86 86Metal rocker black insert 6532-052 86 866531-052Flush mount box: 25mm.Flush mount box: 25mm.20A DP SWITCHES NEON & FLEX OUTLETDESCRIPTION CAT. NO. H WMetal rocker white insert 6531-053 86 86Metal rocker black insert 6532-053 86 866532-053Flush mount box: 25mm.Decorative ScrewlessKEY LOCKABLE6531-121KEY LOCKABLE SOCKETDESCRIPTION CAT. NO. H W13A DP neon white insert 6531-121 86 14613A DP neon black insert 6532-121 86 146KEY LOCKABLE SWITCHDESCRIPTION CAT. NO. H W20A DP Key Lockable switch 6530-060 86 866530-060KEY LOCKABLE

Page 84

84M2 | 6531-2056532-204DESCRIPTION CAT. NO. H WMetal rocker white insert 6531-202 146 86Metal rocker black insert 6532-202 146 862 GANG 45A VERTICAL DP SWITCHES6532-202DESCRIPTION CAT. NO. H WMetal rockers white insert 6531-204 86 146Metal rockers black insert 6532-204 86 146COOKER CONTROL UNITCOOKER CONTROL UNIT NEONDESCRIPTION CAT. NO. H WMetal rocker white insert 6531-203 146 86Metal rocker black insert 6532-203 146 862 GANG 45A VERTICAL DP SWITCHES NEON6531-203DESCRIPTION CAT. NO. H WMetal rockers white insert 6531-205 86 146Metal rockers black insert 6532-205 86 1466532-2001 GANG 45A DP SWITCHESDESCRIPTION CAT. NO. H WMetal rocker white insert 6531-201 86 86Metal rocker black insert 6532-201 86 86Measurements:Millimetres (mm) unless stated otherwiseFlush mount box: 35mmDESCRIPTION CAT. NO. H WMetal rocker white insert 6531-200 86 86Metal rocker black insert 6532-200 86 861 GANG 45A DP SWITCHES NEON6531-201Decorative ScrewlessDOUBLE POLE SWITCHES & COOKER PANELS

Page 85

85 | M2M2Measurements:Millimetres (mm) unless stated otherwiseFlush mount box: 25mmFor euro modules please see page 28DESCRIPTION CAT. NO. H WWhite insert 6531-300 86 86Black insert 6532-300 86 861 GANG COAXIAL OUTLETS6532-3001 GANG COAXIAL ISOLATED OUTLETS6531-3111 GANG SATELLITE OUTLETS6531-3021 GANG COAXIAL & SATELLITE OUTLETS6532-3032 GANG COAXIAL OUTLETS6532-3011 GANG TELEPHONE MASTER OUTLETS6531-3041 GANG TELEPHONE SECONDARY OUTLETS6531-305 1 GANG RJ11 OUTLETS6532-3101 GANG CAT5E DATA OUTLETS6532-306BLANK PLATESDESCRIPTION CAT. NO. H WWhite insert 6531-301 86 86Black insert 6532-301 86 86DESCRIPTION CAT. NO. H WWhite insert 6531-302 86 86Black insert 6532-302 86 86DESCRIPTION CAT. NO. H WWhite insert 6531-303 86 86Black insert 6532-303 86 86DESCRIPTION CAT. NO. H WWhite insert 6531-304 86 86Black insert 6532-304 86 86DESCRIPTION CAT. NO. H WWhite insert 6531-305 86 86Black insert 6532-305 86 86DESCRIPTION CAT. NO. H WWhite insert 6531-306 86 86Black insert 6532-306 86 86DESCRIPTION CAT. NO. H WWhite insert 6531-310 86 86Black insert 6532-310 86 86DESCRIPTION CAT. NO. H WWhite insert 6531-311 86 86Black insert 6532-311 86 86DESCRIPTION CAT. NO. H W1 Gang 6530-030 86 862 Gang 6530-031 86 146Decorative ScrewlessOUTLETS & PLATESEURO MOD PLATESDESCRIPTION CAT. NO. H W1 Gang 1 module white insert 6531-320 86 861 Gang 1 module black insert 6532-320 86 861 Gang 2 module white insert 6531-321 86 861 Gang 2 module black insert 6532-321 86 862 Gang 4 module white insert 6531-322 86 1462 Gang 4 module black insert 6532-322 86 1466532-3206530-030

Page 86

86M2 | 1. Slide metal frame into gasket as shown making sure that flat surface of gasket is facing the wall.2. Insert grid module into frame3. Select which moulded trim you wish to use, white or black and fit around module4. Fix switch assembly to wall box then, clip on cover plateFACE PLATETRIMMODULEGRID FRAMEGASKETDECORATIVE SCREWLESS GRID FEATURESA traditional grid system incorporating mounting frames, modular face plates and modules, face plates available from 1-12 gang to enable multiple switching applications.A full range of modules are available for both commercial & domestic applications. All grid modules are supplied with a black & white trim and are simply swapped to match the insert colour selected for the installation.M2 DECORATIVE SCREWLESSM2 GRID:Decorative Screwless

Page 87

87 | M2M24 MODULE GRID PLATE8 MODULE GRID PLATE12 MODULE GRID PLATE9 MODULE GRID PLATE6 MODULE GRID PLATECAT. NO. H W3011-360 68 1403 & 4 GANG GRID FRAMESuitable for 3, 4, 6, 8, 9 & 12 gang grid plates 3 MODULE GRID PLATECAT. NO. H W3011-359 68 801 & 2 GANG GRID FRAMESuitable for 1 & 2 gang grid plates2 MODULE GRID PLATEDESCRIPTION CAT. NO. H W1 Gang 6530-350 86 861 MODULE GRID PLATEDESCRIPTION CAT. NO.6 & 8 Gang 3011-361132 mm x 132 mm x 47 mm DESCRIPTION CAT. NO.9 & 12 Gang 3011-362192 mm x 132 mm 47 mmGRID FLUSH BACK BOXGRID FLUSH BACK BOXDESCRIPTION CAT. NO. H W2 Gang 6530-351 86 86DESCRIPTION CAT. NO. H W3 Gang 6530-352 86 146DESCRIPTION CAT. NO. H W4 Gang 6530-353 86 146DESCRIPTION CAT. NO. H W6 Gang 6530-354 146 146DESCRIPTION CAT. NO. H W8 Gang 6530-355 146 146DESCRIPTION CAT. NO. H W9 Gang 6530-356 206 146DESCRIPTION CAT. NO. H W12 Gang 6530-357 206 146GRID MODULE PLATESDecorative ScrewlessMeasurements:Millimetres (mm) unless stated otherwiseFor grid modules please see page 26

Page 88

88M2 | • High gloss curved profile• Antimicrobial properties• New products• Fully tested & Certified• Recyclable bags and cardboardANTIMICROBIAL PROPERTIESAs a result of the carefully selected thermoset urea faceplate materialCEILING ACCESSORIESCeiling25 YEAR GUARANTEEThe stand alone M2 ceiling range comprises of all traditional ceiling accessories such as pendants and batten holders, as well as a new range of junction boxes. These boxes are available up to 60A in 3, 4 and 6 terminal options. In addition, the range offers 45A and 50A DP pull cord ceiling switches.KEYFEATURES:M2 CEILING RANGE WIRING ACCESSORIESFEATURES:RECYCLED PACKAGINGThe packaging has been carefully selected throughout the development stages of this range to ensure we minimise our impact on the environment. Both the polybag and the inner cardboard carton are manufactured from recycled content and after use can now be recycled.

Page 89

89 | M2M2DESCRIPTION CAT. NO. L DIA.6” BC 7010-700 150 869” BC 7010-701 225 866” E27 7010-703 150 86PENDANT SETS7010-703DESCRIPTION CAT. NO. H DIA.T2 BC lamp holder 7010-704 60 35LAMP HOLDERDESCRIPTION CAT. NO. H DIA.Straight 7010-705 - 75Angled 7010-706 - 75BATTEN HOLDERS7010-705DESCRIPTION CAT. NO. H W15A 10 Way 7010-716 86 146CONNECTION UNITDESCRIPTION CAT. NO. D DIA.4 Terminal - large 7010-711 30 804 Terminal - small 7010-714 27 606 Terminal 7010-713 30 8620A JUNCTION BOXES7010-711DESCRIPTION CAT. NO. D DIA.5A 4 Terminal 7010-710 36 6230A 3 Terminal 7010-712 36 9060A 3 Terminal 7010-715 40 90JUNCTION BOXES7010-715DESCRIPTION CAT. NO. H W10A 1 Way 7010-720 43 4310A 2 Way 7010-721 43 43CEILING SWITCHES7010-720DESCRIPTION CAT. NO. H W45A 7010-722 43 4350A 7010-723 43 43DP CEILING SWITCHES7010-723DESCRIPTION CAT. NO. H DIA.Ceiling rose 7010-724 33 86CEILING ROSECEILING ACCESSORIESCeiling

Page 90

90M2 | TECHNICAL INFORMATIONTechnical InformationThe design team at RPP play an important role in developing products that combine quality, value and reliability. The technical department supports this effort and are capable of carrying out all the necessary tests for CE/UKCA compliance and BS testing. Our Sales and marketing team work alongside our technical department to ensure product development is done with the maximum input from customers and thereby making certain that product development is T93/68/EEC - The CE mark is a visible declaration by the manufacturer that the equipment which is marked complies with all the requirements of all the applicable European Union (EU) directives.Electromagnetic Compatibility Directive 2014/30/EULow Voltage Directive 2014/35/EUCEcarried out to meet market expectations.All RPP products are manufactured in accordance with the relevant British / European (BS EN) standards.The strength of RPP over the years has been in its design, its investment of tooling and provision of manufacturing, having total control from initial design concept to finished products.ALL PRODUCTS IN THIS CATALOGUE ARE IN COMPLIANCE WITH THE FOLLOWINGSTANDARDS/TESTINGRPP strive for excellence in providing electrical accessory products to our expanding customer base. We place a high value on minimising the impact to the environment, and are committed to the maintenance and improvement of environmental practice in our day to day operations as a manufacturer and distributor.ENVIRONMENTALIn order to achieve our aims, the company will at all times ensure:• Compliance with relevant environmental legislation, regulations and other requirements to meet environmental and customer needs.• Prevention of pollution through the elimination or reduction of emissions and minimizing waste generation through application of reducing, reusing and recycling.• Continual improvement of the impact to the environment of the company’s products and processes. This to be achieved by the gathering of data, analysis and necessary action identified.• Communication of the environmental policy internally to employees and externally as appropriate.• To involve both our customers and our suppliers in a full appreciation of our overall environmental impact.• That environmental objectives and targets to be reviewed at regular intervals.We will engrave to your specified textural detail & Font size across the ranges to the below specification, contact sales on +44(0) 1527 528024 for further assistance. ENGRAVINGPRINTING SPECIFICATIONFont Standard line copyIn-fill Acrylic paintStandard colours Red, white & blackThe UKCA mark is a visible declaration by the manufacturer that the equipment which is marked complies with all the requirements of all the applicable British Standards directives.Electromagnetic Compatibility Regulations 2016Electrical Equipment (Safety) Regulations 2016UKCA

Page 91

91 | M2M2TECHNICAL INFORMATIONThe range of M2 light switches are designed for ease of installation and are available in one or two gang, intermediate and multi-pole switch configurations, there is also double pole switching options available.SWITCHESCOMMON1LAMPLNCOMMON122TWO WAY SWITCHESTwo Way SwitchingCOMMON1LAMPLNCOMMON122DOTTED LINE SHOWS ALTERNATIVE SWITCH POSITIONS22 11TWO WAYSWITCHTWO WAYSWITCHINTERMEDIATESWITCHTwo Way Intermediate SwitchingThe range of M2 dimmer switches are available in one and two gang configurations with up to four operational dimmers on one plate.DIMMERSCOML1LAMPLN1L22DOTTED LINE SHOWS ALTERNATIVE SWITCH POSITIONSTWO WAYDIMMERCOML2L1COMMONTWO WAYSWITCH• One and two way switching available on each dimmer switch.• Integrated over temperature protection fuse fitted (non replaceable).• Leading edge & trailing edge.• For use with inductive and resistive loads.• Dimmer switches available in 400W.• It is recommended that the lamps Manufactured by LIF (Light Industry Federation) members only are used with the M2 range of dimmer switches.COML1LAMPLNL2DOTTED LINE SHOWS ALTERNATIVE SWITCH POSITIONSTWO WAY DIMMERCOML2L1DIMMERSTechnical InformationDESCRIPTION CAT. NO.Electronic Transformer (E) These can be mounted remotely, but are now more commonly an integral part of the light fitting. Normally an output range of between 50-200VA. Not all electronic transformers are dimmable, check with manufacturerToroidal Transformer (T) Most toroidal transformers are dimmable, but confirm with manufacturer. Normal output range up to 400VA. A ‘soft-start’ dimmer should be used with toroidal transformer dimming.Wire Wound Transformer (W/W) These are normally remotely mounted and have the largest range in VA sizes.Note: No dimmers are available for fluorescent lampsDIMMER MODULE GUIDELINESType: 400W 10A SwitchOperational Range 60-400W 10AMax. Mains Voltage 240V 240VMax. Low Voltage Capacity 400W -GU10 Lamp Capacity 400W -Transformer Capacity E / T/ W -

Page 92

92M2 | RCD SOCKETSSUPPLYLNEARTHLOAD‘NEUTRAL TO EARTH FAULT’TRIPSUPPLYLNEARTHLOAD‘LIVE TO EARTH FAULT’TRIPSUPPLYLNEARTHLOAD‘HEALTHY CIRCUIT’PassivePassive controlled RCD sockets incorporate a mechanism which is mechanically latched (closed) in the event of a mains failure situation, the socket RCD will operate under normal residual fault conditions.This type of device is suitable for fridge / freezer applications or in unmanned locations where a possible mains power failure could damage equipment.ActiveActive controlled RCD sockets incorporate a mechanism which is magnetically latched in the closed position and will automatically open in the event of a mains failure situation, the socket RCD will operate under normal residual fault conditions.This type of device is suitable for hazardous equipment which would energise on the return of the mains power, rotary or heating equipment.The range of M2 socket outlets are designed for ease of installation and are available in one or two gang configurations, there are also double pole switching options available.SOCKETSCONSUMERUNIT2NOTE: EARTH REMOVED FOR CLARITY FCU - FUSE CONNECTION UNIT1 - UNSWITCHED SPUR2 - SPUR USING AN FCU NOT CONNECTED DIRECTLY TO RING3 - SPUR USING AN FCU CONNECTED DIRECTLY TO RING4 - FCU SUPPLYING FIXED EQUIPMENT5 - BS1363 SOCKET OUTLETFIXEDEQUIPMENT1345JUNCTIONBOXJUNCTIONBOXJUNCTIONBOXDOMESTIC RING FINAL CIRCUITFOR FLOOR AREA UP TO 100m2REFER TO IEE WIRING REGULATIONSFOR INSTALLATION PRACTICEUSB SOCKETSRed ‘ON’ indication to show position of switch rocker.• Top access twin colour coded angled terminals to help with ease of wiring.• Neon switch rocker indication available.• Captive terminal screws help with installation of sockets.• Silver switching contacts with a 3mm contact gap.COMPLIANCE: BS 1363 PT2:1995 | CE Compliant:93/68/EEC | EN 61000-6-1:2007 | EN 61000-6-3:2007/+A1:2011 | EMC Directive 2004/108/EC | EU REACH Regulation No1907/2006 | UKCAMOUNTING BOXES: Flush (1 gang): 35mm. Flush (2 gang): 25mm. Surface: 29mmTERMINAL CAPACITY: Live & Neutral: 4 x 2.5mm2 | Earth: (dual) 8 x 2.5mm2FACE PLATE MATERIAL: Thermoset Urea / Stainless Steel / SteelSWITCHING: Single PoleCURRENT: 13A | USB rating varies see product pages for more informationVOLTAGE: 230VFREQUENCY: 50HzENVIRONMENTAL ISSUES: Packaging Waste:Cardboard/LDPE4 bags – Made from recycled content and can been recycled. RoHS Complaint – ref: 2011/65/EUThe products manufactured & otherwise supplied by the company do not have any perceived or known hazardous materials or by-products that would be deemed hazardous to the environment.Technical InformationTECHNICAL INFORMATION

Page 93

93 | M2M2TECHNICAL INFORMATIONThe range of M2 telephone and data modules are available in one and two gang configurations with multi-outlet options on one plate.TELEPHONE32 5461MAIN WIRE COLOURSARE SHOWN IN CAPITALS1 - GREEN / white2 - BLUE / white3 - ORANGE / white4 - WHITE / orange5 - WHITE / blue6 - WHITE / green1 2FIRST SOCKET OUTLET(MASTER)34 5 6EXTENSION OUTLET(SECONDARY)654321• Master and extension telephone sockets available.• All connection options available including BNC, RJ45, CAT5, CAT5e and ISDN connectors.• TV and satellite connector PCBs are enclosed in a protective die-cast housing.• TV and satellite connectors available from single connection to four connection versions for all applications.• Non-isolated and fully screened outlets with earth terminal.• Supplementary TV outlets with back feed for further distribution.Technical InformationThe range of M2 ceiling roses are available with either 6” or 9” pendant sets, straight or angled batten holders and ceiling rose or lamp holder with no flex included.CEILING ROSESSWITCHLIVE FEEDLAMPLIVENEUTRALLOOPEARTH7551.658210485802924225.5050Typical pendant wiring schematic• Ceiling roses have eight terminals including Live, Neutral and Loop terminations plus a separate brass earth terminal block.• Ceiling roses can accept 3 x 1.5mm² cable into the Live & Neutral terminal and 5 x 1.5 m² cable into the Earth terminal.• Straight and angled batten holders can accept 3 x 1.5mm² cable into the Live & Neutral terminal and 6 x 1.5mm² cable into the Earth terminal (straight holder) 3 x 1.5mm² cable into the Earth terminal (angled holder).• PVC Heat Resistant 318Y H05VV-F / 0.75mm² x 2 Core 6” or 9” drop

Page 94

94M2 | 6.5mm6.5mmSCREENED BRAID TO REMAIN IN PLACEOVER THE INNER INSULATIONTV CO-AXIALSTRIPPING DETAILSEINOUTCO-AXIAL CABLEDIPLEXTRIPLEXCO-AXIAL CABLECABLE CLAMPQUADSAT 2INSAT 1INETELEVISIONThe range of M2 television sockets are available in Digital and Analogue to include TV, satellite, FM & DAB outlets. The Digital outlets can be used as a main receiving point within the property or an additional point in conjunction with either a Distribution Unit, Combining Unit or Multi Switch.• Digital Outlets are enclosed in a protective die-cast housing.• Non Isolated and fully screened outlets with earth terminals.M2 weatherproof is an IP66 range of weatherproof accessories principally comprising of four main enclosures, accepting either standard one and two gang plate accessory products or our euro modules & plates, M2 weatherproof thereby offers a fully comprehensive range for all outdoor applications.A wide choice of accessories are available including WEATHERPROOF ACCESSORIESBS EN 60529:1991- Degrees of protection provided by enclosuresswitches, sockets, spurs and data outlets.Manufactured from tough polycarbonate with a clear or solid lift up cover and neoprene seals to ensure compliance to IP66. Plug entry seals to clamp onto the flex of the equipment to ensure a tight seal when in operation.FIRST NUMERAL REQUIREMENTS SECOND NUMERAL REQUIREMENTS6 Protected against dust & small particles6 Protected from powerful jets of water from all directionsIP66 SPECIFICATIONTECHNICAL INFORMATIONTechnical Information