Liberty independence Double Electric Breast Pump User Manual for Freemie Liberty and Independence Mobile Pumps IMPORTANT Read this manual prior to use Please save this manual Review the most current manual at www freemie com This manual contains important information for the proper sanitization use and care of your Freemie Liberty or Independence breast pump system Please visit our website www Freemie com for customer service and all your spare parts needs
Congratulations on your purchase and thank you for choosing Freemie Liberty Independence Your Freemie mobile pump is designed to help make your pumping experience compatible with your life allowing you greater flexibility to pump whenever and wherever necessary Intended Use The Freemie Liberty Independence pump is a powered breast pump to be used by lactating women to express and collect milk from their breasts The Freemie Liberty Independence pump is intended for use by a single user Contraindications For Use There are no known contraindications for use of this product Product Description The Freemie Liberty or Independence is a personal use electric breast pump and is capable of single and double pumping The operating life of the Freemie Liberty is defined to be normal expected use of up to three pumping sessions of 20 minutes per day for one year The operating life of the Freemie collection kit is defined as 60 days Important Notice If you have any concerns about your health or experience any pain while nursing or using any breast pump stop pumping immediately and consult your health care or lactation professional immediately DAO Health does not give medical advice or lactation advice make diagnoses or recommend treatment WARNING Never use your Freemie mobile pump in any location situation or circumstances that are unsafe for you your infant or others 2
Table of Contents Intended Use 2 Contraindications for Use 2 Product Description 2 Important Safety Instructions 4 5 Freemie Liberty Independence System 6 Pump the Freemie Way 7 Freemie Liberty Pump Features 8 Freemie Independence Pump Features 9 Preparing Freemie for First Use 10 11 Sanitizing 11 Cleaning 12 Assembling Freemie Cups 13 Connecting to Your Freemie Liberty Independence Pump 14 Attaching and Removing Your Clothing Clip 15 Positioning Within Your Bra 16 18 Correct Nipple Position and Funnel Sizing 16 17 Before Pumping with Freemie 19 Freemie Liberty Pump Controls 20 Freemie Independence Pump Controls 21 Pumping with Freemie 22 23 Disconnecting and Transferring Your Milk 23 24 Proper Storage of Breast Milk 24 25 Troubleshooting Tips 25 26 Warranty and Specifications 27 EMC Guidance 28 Symbols on the Pump 28 Spare Parts and Customer Service 29 3
Important Safety Instructions READ ALL INSTRUCTIONS BEFORE USING THIS PRODUCT This is a single user product Use by more than one person may present a health risk and will void the warranty When using electrical products especially when children are present basic safety precautions should always be followed DANGER To reduce the risk of electrocution Always unplug electrical product immediately after charging Do not use while bathing showering or swimming Do not place or store product where it can fall or be pulled into a tub or sink Do not place or drop into water or other liquid Do not reach for product if it has fallen into water WARNING To avoid damage electric shock or fire This device cannot be serviced or repaired Do not attempt to open the device Do not repair yourself Do not modify the device Do not attempt to replace lithium ion battery Do not attempt to modify firmware Never leave product unattended when plugged into electrical outlet Micro USB cable is for charging only and does not provide a data connection to pump Never use or charge pump below 10 C 40 F or above 40 104 F Never use if any type of liquid is detected from inside the pump This could be a sign that the battery is damaged or that liquid has entered pump through tubing which will damage the pump Contact customer service Close supervision is necessary when this product is used near children or persons with disabilities Use product only for intended use as described in this manual Only use attachments recommended by the manufacturer Use with unapproved collection systems may cause injury to you and damage to your pump Never operate this product if it has a damaged cord or plug if it is not working properly if it has been dropped or damaged or dropped into water Keep cord and all attachments away from heated surfaces Never charge pump during use while sleeping or when drowsy Do not operate where aerosol spray products are being used or where oxygen is being administered Do not use solvents or abrasives on any components Do not put any Freemie components in the dishwasher or steam sterilize WARNING To avoid health risk and reduce the risk of injury Never use a damaged device Replace damaged or worn parts Never use if moisture or liquid is detected in pump s tubing Only use with Closed System Freemie Cups with Tongue shaped barriers inside cups Always inspect the flexible tongue shaped barrier page 6 for damage cuts tears or holes Use of a damaged barrier will cause milk to flow into the tubing and pump motor This can damage the pump motor and compromise hygiene Use of a damaged barrier will void your warranty 4
Important Safety Instructions Continued If pumping is uncomfortable or causing pain turn the unit off and if necessary break the seal between the breast and breast funnel immediately with your finger and remove the breast funnel from your breast Do not try to express with vacuum that is too high and uncomfortable painful If all breast pumps are painful for you even on their lowest suction settings consider consulting with your lactation or health care professional Always inspect funnels cups valve bases duckbill valves barriers and tubing prior to use for cleanliness Clean sanitize and dry all parts that come in contact with your breast and breast milk prior to first use See page 11 and 12 for sanitization and cleaning instructions Disassemble clean and dry all parts that come into contact with your breast and breast milk after every use Do not store wet or damp parts where mold may develop Use Freemie Cups only with Freemie compatible pumps Use with non compatible pumps may cause injury to you or damage your pump Misuse may void warranty Visit Freemie com for the current compatibility list As a general rule use Freemie only as often and only as long as you normally breastfeed your baby Consult a lactation professional if you have questions about your milk supply Consult your lactation professional if you have questions about whether Freemie is appropriate for you or to help determine the correct funnel size for you Freemie is not recommended if you must watch your milk ejection reflex or aggressively massage your breasts while pumping to ensure that they are completely emptying Do not share Freemie is a personal use item Do not use Freemie for simultaneous breastfeeding and pumping with compromised infants without first consulting your healthcare or lactation professional Do not continue to use Freemie if you experience pain or discomfort in the breast or nipple while pumping Do not pump or pump and nurse in situations or places that may present any risk to you or your infant Keep out of reach of infants and children Freemie has small parts that can be choking hazards If you are a mother who is infected with Hepatitis B Hepatitis C or Human Immunodeficiency Virus HIV pumping breast milk will not reduce or remove the risk of transmitting the virus to your baby through your breast milk 5
Freemie Liberty and Independence Pump Systems The Freemie Mobile Pump System includes Collection Components 2 Closed System Barrier FG072 2 Valve Base Closed System FG071 3 Duckbill Valve Closed System FG073 4 Breast Funnel Closed System 2 25mm FG069 2 28mm FG070 28mm Breast Funnels and extra Duckbill Valve not included in the Independence Standard Set 2 Cup Closed System FG068 Connection Kit Closed System FG067 3 Tubing 1 Y Connector Pump Components 1 Liberty Pump OR 1 Independence Pump 6 1 Pump Clothing Clip FG074 1 Power Adapter Kit including USB Charging Cord and Wall Charge Adapter FG075
Pump the Freemie Way Pump Efficiently Travel Pump and Relax At Pump While Bonding Freemie can be used for single or double pumping as desired Home Use the Adjustable Auto Shut Off Timer to program your pumping session without watching the clock You can close your eyes and sit in the recliner and make baby s milk for tomorrow while tonight s dinner is in the oven Auto Shut Off Timer not included on Independence model pumps Travel with Freemie to express your milk on the go Pump anytime anywhere Freemie can be used to pump milk while breastfeeding Place baby on one breast and Freemie cup on the other Sleep in a little longer and pump that first bottle of the day while baby fills up Work Pump discreetly at your work station without ever undressing Get your work done and get home Milk contacting components not made with BPA DEHP or natural rubber latex Freemie Collection Cup Features Overflow Protection to Keep Milk Out Of The Tubing Tubing Connection Port Easy Pour Spout 8 Ounce 240 mL Capacity per cup Spill Guard Finger Grip Internal Barrier For Pump Protection Spill Guard Flat Base 7
Freemie Liberty Pump Features 3 Customizable Memory Settings Create and save the perfect suction and speed for stimulation and set different patterns for power pumping or more relaxed pumping Can be re programmed at any time Easy to Use Interface with Backlit LCD Screen Look at LCD straight on for correct readouts Power On Off Key Timer begins countdown to shutoff from 40 minutes Micro USB Charging Port Speed and Suction Increase and Decrease Keys Compatible with many phone chargers Adjust speed down from 1 to reach Adjustable Auto Shut Off Timer Turbo Mode for Freemie s extended pull cycle Tubing Connection Port Use tubing location to orient Press once to set pump to shut off in 5 minutes Press multiple times in quick succession to add time in 5 minute increments up to 40 minutes yourself to location of controls for operation while pump is concealed out of sight e g On Off is at 9 o clock Included Freemie Mobile Pump Accessories Removable Pump Clothing Clip 8 Wall Charger Adapter allows for wall outlet charging Micro USB to USB Cord allows for computer or car charging
Freemie Independence Pump Features 3 Customizable Memory Buttons Create and save the perfect suction and speed for stimulation and then set different patterns for power pumping or more relaxed pumping with additional memory buttons Can be re programmed at any time as your needs change LED Lights LED lights indicate speed and suction levels Power On Off Key Timer begins countdown to shutoff from 40 minutes Micro USB Charging Port Speed and Suction Increase and Decrease Keys Compatible with many phone chargers Adjust speed down from 1 to reach Turbo Mode Turbo Mode for Freemie s extended pull cycle Turbo Indicator Light will turn on Turbo light comes on to indicate Turbo Mode Tubing Connection Port Use tubing location to orient yourself to location of controls for operation while pump is concealed out of sight e g On Off is at 9 o clock Included Freemie Mobile Pump Accessories Removable Pump Clothing Clip Wall Charger Adapter allows for wall outlet charging Micro USB to USB Cord allows for computer or car charging 9
Preparing Freemie for First Use This pump contains non replaceable rechargeable Lithium ion batteries Charge battery fully prior to use approximately 2 to 3 hours A fully charged battery will provide approximately 2 5 hours operation time approximately two days based on normal use of up to three 20 minute pumping sessions per day Your pump may also be used while charging WARNING Do not charge pump during use if you are sleeping or drowsy Battery charging time from a fully depleted battery is approximately 3 5 hours If you are travelling outside the US with your Freemie Mobile pump system use appropriate plug adapters NOTE This pump contains rechargeable Lithium ion batteries which may be restricted from the country you are visiting Please consult with the country you are visiting to find out if there are any restrictions that pertain to Lithium ion For information about traveling with your breast pump see www TSA gov 10
Preparing Freemie for First Use Continued Disassemble and clean Freemie Cups prior to first use Follow the instructions below to sanitize these parts Remove cup from funnel Remove barrer and valve base from funnel Remove barrier and valve from valve base Sanitize Parts Do not steam sterilize or dishwash any Freemie components Doing so may cause the parts to warp or not fit securely and will void your warranty Parts must be thoroughly dry before use Boil These Parts Breast Funnel Boil only these parts for 10 minutes to sanitize and ensure parts fit securely in an uncovered pot Covered pots or other systems that trap steam can generate super heated steam which may damage parts Do not let parts sit on the bottom of the boiling pot Parts should float freely Carefully remove from water and be sure to wash and dry parts after boiling Valve Base Natural Shape Cup DO NOT Boil These Parts Duckbill Valve Tubing Barrier Y Connector DO NOT boil or steam these parts Hand wash only Hand wash valve and barrier using plenty of hot water and liquid dishwashing soap then rinse clean with hot water for 10 15 seconds Allow parts to cool and dry completely before use 11
Regular Cleaning After Each Use Do not steam or boil tubing barriers or valves as it will cause damage Do not put any Freemie components in dishwasher or steam sterilizer as it can cause parts to warp and leak Before each use visually inspect the individual components for cracks chips tears discoloration or deterioration In the event that damage to the device is observed please discontinue use until the parts have been replaced Dry parts completely and leave parts disassembled 1 Disassemble and wash all components that come into contact with breast milk Cup Breast Funnel Valve Valve Base Barrier 2 Hand wash parts using plenty of warm water and liquid dishwashing soap then rinse clean with hot water for 10 to 15 seconds Allow part to cool and dry completely before use 3 Treat all parts with special care Avoid abrasives and excessive heat Inspect the Closed System Barrier for rips or tears prior to each use Rips or tears will cause the Closed System Barrier to not function properly possibly causing damage to your pump If the barrier has been compromised replace prior to pumping 4 Clean and dry as soon as possible after each use 5 When not in use store parts un assembled and out of reach from infants and children 6 Do not store assembled Freemie parts in refrigerator parts may become loose or leak 12
Assembling Freemie Cups Always wash hands prior to assembling Freemie cups All parts must be completely dry correctly positioned and pressed securely together Inspect the device before each use for signs of wear or damage and replace parts if signs of wear are noted Step 1 Step 2 Place Barrier onto funnel mounting ridge and against cone surface Align Valve Base with Barrier and Funnel and push together Step 3 Step 4 Press Breast Funnel and Valve Base firmly together Place Valve onto Valve Base Step 5 Cup arrow Note Arrow on cup is difficult to see but can be felt above Freemie logo Locate arrow with your finger and align it to tubing port to assemble Align Cup arrow with Funnel tubing port seat cup rim into outer ring of funnel and snap together You should feel a crisp snap and then assembly is secure Align cup arrow with Funnel tubing port circular Note Do not align arrow with pour spout egg shaped 13
Connecting to Your Freemie Liberty Independence Pump Single Pumping Note For all tubing connections press in firmly until you get a secure connection Close unused tubing port with attached plug press all the way in Double Pumping AVOID SETUP FRUSTRATION BEFORE PLACING THE FREEMIE CUPS IN YOUR BRA After the cups are assembled and connected to the pump turn on pump and observe the tongue shaped barrier inside each cup If all parts are assembled securely and correctly you will be able to observe movement or compression in the tongue shaped barrier when the pump is running At the highest suction settings the barrier will collapse and curl with each cycle similar to the movement of your baby s tongue while sucking If there is no movement in one or both cups re check the assembly and all tubing connections 14
Attaching and Removing Your Clothing Clip To Attach Slide clip into slot in bottom of pump and snap into place Clip will click into place when secure and is designed to wiggle a little Use clothing clip to attach pump to clothing pocket belt purse etc NOTE Clip is only intended for relatively stable use THIS IS NOT A SPORTS CLIP Be careful you don t drop your pump To Remove 1 With gentle pressure just below ribs slide clip down towards pump to disengage latch 2 Press clip slowly towards the base of the pump and carefully begin to slide upward to disengage from catch 3 Slide clip away from pump out of slot 15
Positioning Within Your Bra Finding The Ideal Bra Fit For You When getting started with your new Freemie hands free pump be aware that bra fit is critical to the proper use of this device because your bra must now do the job that your hands would be required to do with a traditional pump 1 Before choosing a bra pump with your new Freemie Mobile pump system using your hands to hold the Cups in place Consider how much pressure you normally apply against your breasts to pump and observe the optimal position and orientation of the cups on each of your breasts Note most women are not perfectly symmetrical and improper positioning or pressure on one or both breasts may result in low output This may happen with traditional or hands free pumping systems if you do not spend the necessary time to figure out how to make the pump work well and effectively for you on each of your breasts This needed pressure may be different when your breasts are engorged versus when they are empty To achieve the same pressure and sensation with the Freemie Cups in your bra it may be necessary to adjust your bra or try different bras to get the best fit for you A sports bra works well for many women 2 Be sure your bra keeps the Freemie cups in an upright position and does not allow the device to slip around sag downward or tilt off to the side during use as a loss of suction may occur 3 Place Freemie inside your bra with the Breast Funnel opening centered over the nipple 4 Make sure you achieve a good seal between Freemie s funnels and your skin Correct Nipple Position Funnel Sizing Ensure nipple is centered in the Breast Funnel and not bent or pinched off If the tip of the nipple hurts while expressing check that the nipple is in the center of the funnel Correct Position 16 Incorrect Position
Positioning Within Your Bra Continued Check Breast Funnel Fit Turn on the pump and check the following points Is the nipple rubbing or sticking against the side Does the base of the nipple blanche during the expression session Does it feel painful If the answer is yes to any of the above a different size funnel may be needed With properly fitted breast funnels the nipple moves in and out of the funnel freely The areolar tissue should move only a little and there should be no pain See our sizing guides at www freemie com Note you may need a different size funnel for each breast for an optimal pumping experience You need a different size if the provided funnels are too big or too small Too Small Too Large Correct Size Funnel is too small for the nipple to move freely in and out of funnel causing rubbing or chafing Funnel is too big allowing too much breast and areolar tissue to be drawn into funnel Funnel is correct size Additionally enough pressure needs to be applied to create a good seal without compressing or obstructing milk ducts Bra fit is critical to allow comfortable and effective pumping Internal Diameter is measured across the opening 25mm 28mm DAO Health cannot help you determine your correct funnel size by email or phone If you have questions about how to find the right breast funnel size for you please consult with your lactation professional 17
Positioning Within Your Bra Continued Tubing Port Should Be In The 12 O Clock Position When connected to a pump tubing port and pour spout must be in the 12 o clock position 12 Correct When filling with milk keep in the upright position Tubing in 12 o clock position Incorrect Placement at any other position can cause milk to flow out of cups while you are pumping Milk leaking from cups 18
Before Pumping With Freemie Breast Pump System Pump with Freemie Cups in an upright position such as sitting or standing You may pump in any of these positions The position of the cups relative to the horizon is important as your milk needs to flow downhill in the funnel Optimal Okay May cause milk to spill May cause milk to spill Incorrect Note Depending on the shape and orientation of your breasts you may be able to comfortably pump in a wide variety of positions 19
Freemie Liberty Pump Controls Customizable Memory Buttons Power On Off Adjust Auto Shut Off Timer Increase Decrease Suction Strength Increase Decrease Speed for suck and release cycles Freemie Liberty Pump Display Indicators Auto Shut Off Timer Suction Setting Displays 1 10 1 weakest 10 strongest Battery Charge Meter displays bars and percentage Speed Setting Displays Turbo 1 10 10 fastest suction and release cycle Turbo slowest suction and release cycle Memory Setting Displays M1 M2 or M3 when memory setting is activated Auto Shut Off Timer activated top half of logo disappears You may find it helpful to start with a higher speed and weaker suction to trigger the stimulation phase and adjust to a lower speed and stronger suction as you move into the expression phase 20
Freemie Independence Pump Controls Customizable Memory Buttons with Indicator Lights Power On Off Increase Decrease Suction Strength Increase Decrease Speed for suck and release cycles Suction Indicator Lights 1 Weakest 10 Strongest Battery Charge Indicator Speed Setting Indicator Lights 1 Slow 10 Fastest Suction and Release Cycle Turbo Mode Indicator Light turns on when speed setting is adjusted down for Turbo extended pull cycle 21
Pumping with Your Freemie Mobile Pump System 1 Power On Off Turn on pump by pressing Power button Turn off pump by pressing Power button again NOTE charging can take up to three and a half hours depending on current charge Pump may be used while charging NOTE A fully charged battery meter reads 100 on LCD or 4 bars on LED display should provide approximately two and a half hours of operation time 2 Whenever the pump is turned on the pump starts at low suction setting 1 and fastest speed setting 10 3 Suction level and Speed can be adjusted Press arrow up or arrow down keys to change suction level or speed 4 Suction levels and Speeds can be adjusted to your preference Note Slowly increase until you feel a comfortable suction Note If you turn up suction to max 10 and do not feel any suction stop pumping and check all connections to ensure they are secure Warning If you feel excessive suction more than usual check your barrier for rips or tears If the barrier is damaged stop and replace prior to pumping a To increase the cycle Speed shorten the suck and release time press Speed arrow up key b To decrease the cycle Speed lengthen the suction and release time press Speed arrow down key Note If at any time the suction is uncomfortable or causes pain press the suction arrow down key to lower the suction level one level at a time until you reach a comfortable level or turn off pump 5 Turbo Turbo mode is Freemie s proprietary extended suck and release cycle Turbo mode provides an extended pull at any suction level allowing you more versatility with your pump settings Press the Speed arrow down key until Turbo is displayed on the LCD screen on the Liberty model pump or the indicator light turns on on the Independence model 6 Multi Mode Memory To program your current suction and speed setting into one of the memory buttons press and hold one of the multimode memory buttons labeled 1 2 or 3 on the pump and hold for at least 3 seconds The Liberty s LCD display will display the memory button that was programmed These settings can be recalled by pressing and quickly releasing the memory button Indicator lights will appear above the memory button selected on the Independence 7 Auto Shut Off Timer Feature not available on Independence model When the pump is turned on the timer starts at 40 minutes and counts down to 0 At 0 the pump turns off automatically If you wish to pump more than 40 minutes simply turn the pump on again The Liberty pump can be programmed to turn off in 5 minute increments by pressing the Auto Shut Off Timer key When the half moon button is first pressed 5 minutes will display and begin counting down to shutoff If pressed again quickly one or more times within 2 seconds the program time will increase by 5 minutes each time the button is pushed to a maximum of 40 minutes 22
8 As with any new pump expect a period of adjustment to the hands free and fully concealed pumping experience After a few days using your new mobile Freemie pump review the instructions for bra and funnel fit to evaluate any needed adjustments Consider what items in your wardrobe work well and make you comfortable while pumping You may also find that other people are more comfortable in your presence while you are pumping with your clothes on when compared to alternatives Each Freemie Cup holds 8 ounces 240 mL of breast milk NOTE When the Freemie Cups are full turn off pump and pull tubing from Freemie Cups while still wearing Freemie Cups in your bra See below When You Are Done Pumping If you produce more than 8 ounces 240 mL per breast stop pumping when the Freemie Cups are full and empty each cup If you have a second Freemie Collection Set that is compatible with Freemie s mobile pump system switch out full Freemie Cups with empty Freemie Cups to minimize pumping interruptions Stop the pump To stop the pump shut it off or break the suction by inserting your fingers between the funnels and your breasts if necessary If you experience pain in your breast or nipple even if you think the pump is not the source of the pain consult your health care or lactation specialist Disconnecting and Transferring Milk When you are done pumping 1 Turn off pump 2 Leave Freemie in your bra and gently pull the tubing from the device 3 Carefully remove cups from your bra 4 Freemie cups may be set flat on a table until ready to transfer to a storage container 23
Pouring Milk into a Container Practice with water first to achieve successful transfers without spilling it s easy Handle a full Freemie cup with care Milk that has not passed through the valve and into the cup can spill out of the Breast Funnel Pour Spout Use pour spout for transferring milk into storage containers Fully disassemble and clean immediately after transferring milk to get ready for next use Refer to page 12 Proper Storage of Breast Milk How long can I store breast milk Location Temperature Duration Comments Countertop table Room temperature 6 8 hours up to 77 F or 25 C Insulated cooler bag 5 39 F or 15 4 C 24 hours Keep ice packs in contact with milk containers at all times limit opening cooler bag Refrigerator 39 F or 4 C 5 days Store milk in the back of the main body of the refrigerator Containers should be cover and kept as cool as possible covering the container with a cool towel may keep milk cooler Freezer Freezer compartment 5 F or 15 C of a refrigerator Freezer compartment 0 F or 18 C of a refrigerator with separate doors Chest or upright deep 4 F or 20 C freezer 2 weeks Store milk toward the back of the freezer where temperature is most 3 6 months constant Milk stored for longer durations in the ranges listed is safe but some of the lipids in the 6 12 months milk undergo degradation resulting in lower quality Source Proper Handling and Storage of Human Milk cdc gov 24
How do I thaw and use stored breast milk Always make sure to check the date on the milk s container before using Do not use undated milk or milk that has been stored too long Thaw frozen milk in the refrigerator or under cool running water Heat the milk under warm running water and gently swirl the container to mix the milk If warm water is not available heat a pan of water on the stove Once the water is warm not boiling remove the pan from the stove and place the milk container in the pan Never warm the milk container directly on the stove Never microwave breast milk because microwaves can cause dangerous hot spots that could burn you or a baby Always test the temperature of the milk on the inside of your wrist before feeding it to a baby The milk should feel warm not hot After thawing milk should be stored in the refrigerator for no more than 24 hours Never refreeze thawed milk Throw away previously frozen milk that is not used within 24 hours Troubleshooting Tips Breasts Not Emptying Review Positioning Within Your Bra Pages 16 18 Always center Breast Funnel over nipple If the Breast Funnel is off the center of the nipple you may impede milk release experience loss of suction or prevent the complete emptying of the breast Try adjusting the position of Freemie Comfortably position your body to help create the best seal between Freemie and your skin Experiment with your body position by sitting up straighter leaning forward a little or pulling your shoulders back The Breast Funnels come in the standard 25mm and 28mm Visit www Freemie com for the latest in sizing options and accessories Note If you require a funnel diameter or depth that we do not currently offer then unfortunately we do not recommend the Freemie system as your full time pump If problems emptying your breasts persist consult your lactation professional 25
Troubleshooting Tips Continued Loss of Suction Review Assembling Freemie Cups Pages 13 14 Make sure pump is turned on motor is running and suction level is turned up to your regular setting Make sure that parts are correctly assembled and fit together as snugly as possible and that connection to the pump is secure see pages 12 and 13 If the fit between the valve base and funnel is loose try replacing the valve base with a new valve base If suction is diminished try replacing the duckbill valve with a new duckbill valve Make sure tubing is not kinked or pinched Make sure tubing is pushed securely into its port on the breast funnel see page 14 Make sure Breast Funnel is securely pressed against breast creating a seal around nipple and is properly seated in bra Check that no bra material or tubing is between the device and your skin The device should not be tilting upward downward or to the side see pages 18 and 19 Make sure nipple is not bent or pinched inside the Breast Funnel see page 16 Try a tighter fitting bra to ensure that the bra is able to support and maintain an adequate seal and hold Freemie in an upright position Consider trying a sports bra see page 16 When single pumping be sure Y connector plug is on securely inserted into open port see page 14 Ensure barrier is properly assembled If pump lights are on but no vibration is detected from pump even at highest suction settings contact customer service Milk in Tubing Ensure that all parts are firmly assembled and that barrier is not damaged 26
Warranty Specifications Warnings Note The Freemie mobile breast pumps are Personal Use Items and cannot be returned once opened The Freemie Liberty Independence Pump mechanism is guaranteed against defects in materials and workmanship for a period of one year of normal use from the date of purchase with proof of purchase Normal use is defined as up to three 20 minute pumping sessions per day for one year Other parts and accessories of the Liberty Independence Pump and The Freemie Closed System Collection Cups are guaranteed against defects in materials and workmanship for a period of 60 days Warranty can only be claimed in the country of purchase through authorized Freemie distributors Warranty does not cover misuse abuse or excessive wear and tear Spare parts are available at www freemie com Plastic parts do wear out with regular use so plan ahead to avoid disruptions to your pumping routine In the event of a verifiable defect that is not the result of misuse abuse excessive wear and tear or alteration Dao Health will replace or repair this product at Dao Health s discretion Returns will not be accepted without a return merchandise authorization which must be obtained from Dao Health s customer service All shipping costs are the responsibility of the shipper Note Failure to use and maintain the Barrier in good condition may cause damage to your pump and will void your warranty If milk flows into the tubing turn off the pump immediately Refer to the user manual for instructions on cleaning or replacing tubing replace Barrier Failure to turn off the pump when milk gets in the tubing will cause damage to your pump Disposal The pump unit and power adapter must not disposed of with normal household waste but should be taken to a collection point for recycling electric and electronic equipment Specifications Medical Device Protection Type CISPR 11 Group 1 Class B Class 11 a Power Adapter Input 100 240V 50 60Hz 0 2A Output 5V DC 1000mA Liberty Independence Pump 5V DC 5 500 mA Battery Capacity and Type 2200mAh 3 7V 8 14Wh Polymer Li Ion Pump Weight 0 55 lbs Temperature Humidity Range Operation Temperature Humidity Range Storage 50 F 104 F 10 C 40 C 25 95 32 F 122 F 0 C 50 C 30 70 Temperature Humidity Range Charging 50 F 113 F 10 C 45 C 30 70 Water and Dust Protection Class IP22 27
EMC Guidance Warnings This pump may have problems operating when it is used near household items that emit electromagnetic waves such as small appliances and television or video equipment Do not operate pump near other electronic equipment Static electricity can damage your pump Virtually all electronic equipment portable and mobile RF communications equipment can affect medical electrical equipment Do not stack units as EMC emissions can result FCC Part 15 This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate incidental radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However this device does not contain any WiFi bluetooth NFC or other transmitters or receivers but there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna of the affected equipment Increase the separation between this equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the affected receiver is connected Consult the dealer of the affected equipment or an experienced radio TV electronics technician for help Symbols on the Pump ON THE PUMP MOTOR UNIT Symbol Meaning Do not dispose of pump or voltage adapter with household waste Refer to the operating instructions and warnings 28 Symbol S N Meaning Serial Number Application part type BF
Spare Parts Customer Service Available on our website www freemie com Freemie Liberty Pump with Closed System Collection Cups Part Part Name Picture FG063 Closed System Collection Cups Set See Website FG067 Closed System Connection Kit See Website FG068 Closed System Cups Spare Parts See Website FG069 25mm Closed System Breast Funnel See Website FG070 28mm Closed System Breast Funnel See Website FG071 Closed System Valve Base See Website FG072 Closed System Barrier See Website FG073 Closed System Duckbill See Website FG074 Clothing Clip See Website FG075 Power Adapter Kit See Website FG057 15 16mm Fitmie Accessories See Website FG058 17 18mm Fitmie Accessories See Website FG059 19 20mm Fitmie Accessories See Website FG060 21 22mm Fitmie Accessories See Website FG061 23 24mm Fitmie Accessories See Website FG062 25 26mm Fitmie Accessories See Website FG064 21mm Fitmie Accessories See Website FG065 22mm Fitmie Accessories See Website For help with your Freemie product visit us at www freemie com Customer Service 916 339 7388 Monday Friday 9 00am 5 00pm PST P150 B 29