Return to flip book view

Heat pump pack brochure

Page 1

Ground and air source heat pumps01 | 2024

Page 2

2 | 3Our HPEasy concept means our products are wrapped in a full suite of services and tools for installers that help you specify, quote, buy, install and handover systems with the maximum speed and the minimum of fuss. HPEasy means you are supported from start to nish with the highest quality products and services.Our heat pump sets with integrated components for easy, fast, fail-safe installations are a key way we make your life easier. Our high quality products never fail to impress with their superior build quality, excellent reliability and whisper quiet operation. Need help determining an estimated heat requirement for indicative quotations? Don’t worry! Our HPeasy ethos means we have a tool for the job! Our heat pump navigator will get you started without the cost and time involved in a full heat loss calculation (a full heat loss calculation should still be carried out before your system design is nalised)Try the navigator now: STIEBEL ELTRON Navigator (www.stiebel-eltron.co.uk/toolbox/navigator/) - enter the building data (it takes a minute) to step 7 and an automatic heat loss estimate will be produced. You can then follow the tool to the end to specify a system or hop back here and do it ofine where you can see all the options to choose between.Stiebel Eltron NavigatorJust select the pack groups from the tables below that match your requirements and go to the relevant pages for individual pack details and how to choose between them.Heat loss toolarge? Call us to discuss designs for multiple heat pumps in cascade formationor commercial400V units.Minimum heat requirement at -3°CMaximum heat requirement at -3°CHeat Pump Model Hot water requirementGround source heat pumps with separate cylinders with passive cooling option1 to 4 WPE-I 04 HK None or up to 2 beds & 1 bathroom only1 to 6 WPE-I 06 HK None or up to 5 beds & 3 standards baths1 to 8 WPE-I 08 HK None or up to 5 beds & 3 standards baths2 to 12 WPE-I 12 HK None or up to 5 beds & 3 standards baths2 to 15 WPE-I 15 HK None or up to 5 beds & 3 standards bathsGround source heat pumps with integral cylinder for small footprint (no cooling)1 to 4 WPE-I 04 HW Up to 3 beds & 1 bathroom only1 to 6 WPE-I 06 HW Up to 3 beds & 1 bathroom only1 to 8 WPE-I 08 HW Up to 3 beds, bath & ensuite2 to 12 WPE-I 12 HW Up to 3 beds, bath & ensuite2 to 15 WPE-I 15 HW Up to 3 beds, bath & ensuiteAir source heat pumps – active cooling options with some packs – see individual packs for details2 to 7.5 WPL-A 07 or HPA-O 8 Up to 3 beds, bath & ensuite2.5 to 8.5 HPA - O 8 Up to 5 beds & 3 standards baths6.5 to 14 WPL 25 ACS Up to 5 beds & 3 standards baths

Page 3

2 | 3Our HPEasy concept means our products are wrapped in a full suite of services and tools for installers that help you specify, quote, buy, install and handover systems with the maximum speed and the minimum of fuss. HPEasy means you are supported from start to nish with the highest quality products and services.Our heat pump sets with integrated components for easy, fast, fail-safe installations are a key way we make your life easier. Our high quality products never fail to impress with their superior build quality, excellent reliability and whisper quiet operation. Need help determining an estimated heat requirement for indicative quotations? Don’t worry! Our HPeasy ethos means we have a tool for the job! Our heat pump navigator will get you started without the cost and time involved in a full heat loss calculation (a full heat loss calculation should still be carried out before your system design is nalised)Try the navigator now: STIEBEL ELTRON Navigator (www.stiebel-eltron.co.uk/toolbox/navigator/) - enter the building data (it takes a minute) to step 7 and an automatic heat loss estimate will be produced. You can then follow the tool to the end to specify a system or hop back here and do it ofine where you can see all the options to choose between.Stiebel Eltron NavigatorJust select the pack groups from the tables below that match your requirements and go to the relevant pages for individual pack details and how to choose between them.Heat loss toolarge? Call us to discuss designs for multiple heat pumps in cascade formationor commercial400V units.Minimum heat requirement at -3°CMaximum heat requirement at -3°CHeat Pump Model Hot water requirementGround source heat pumps with separate cylinders with passive cooling option1 to 4 WPE-I 04 HK None or up to 2 beds & 1 bathroom only1 to 6 WPE-I 06 HK None or up to 5 beds & 3 standards baths1 to 8 WPE-I 08 HK None or up to 5 beds & 3 standards baths2 to 12 WPE-I 12 HK None or up to 5 beds & 3 standards baths2 to 15 WPE-I 15 HK None or up to 5 beds & 3 standards bathsGround source heat pumps with integral cylinder for small footprint (no cooling)1 to 4 WPE-I 04 HW Up to 3 beds & 1 bathroom only1 to 6 WPE-I 06 HW Up to 3 beds & 1 bathroom only1 to 8 WPE-I 08 HW Up to 3 beds, bath & ensuite2 to 12 WPE-I 12 HW Up to 3 beds, bath & ensuite2 to 15 WPE-I 15 HW Up to 3 beds, bath & ensuiteAir source heat pumps – active cooling options with some packs – see individual packs for details2 to 7.5 WPL-A 07 or HPA-O 8 Up to 3 beds, bath & ensuite2.5 to 8.5 HPA - O 8 Up to 5 beds & 3 standards baths6.5 to 14 WPL 25 ACS Up to 5 beds & 3 standards baths

Page 4

Our domestic ground source packs with a passive cooling option (does not require compressor to start – works simply with moving the heat from your home with your circulating pumps). Every pack comes with a 100 litre buffer and a 290 litre DHW cylinder. Simply choose the correctly sized heat pump for the your project.Set of components WPE-I 04-15 HK 230 Premium Pack1 Type WPE-I HK 230 (size dependent on pack chosen) Quantity 1 Product Ground source heat pump2 Type SBP 100 classic Quantity 1 Product Buffer cylinder3 Type SBB 300 Trend Quantity 1 Product DHW cylinder4 Type WPSF Quantity 1 Product WPSF multifunction brine filling unit5 Type FS-WP 28 Quantity 2 Product Filter sets6 Type WPKI-HK ME Quantity 1 Product Heating circuit assembly for heating circuit without mixer7 Type UP 25-60 B Quantity 1 Product Circulation pump for external DHW heating8 Type FET Quantity 1 ProductDigital remote control9TypeISG web Quantity 1 Product Internet Service Gateway10 Type TAF PT 2m Quantity 2 (*1) Product Immersion/contact sensorWPE-I 04 HK 230 Premium PackWPE-I 06 HK 230 Premium PackWPE-I 08 HK 230 Premium PackWPE-I 12 HK 230 Premium PackWPE-I 15 HK 230 Premium Pack Part number 204399 204405 204402 204407 204404See more detailsof each packApplication • This ground source heat pump with output-dependent control and inverter technology is installed indoors and combined with a separate buffer and DHW cylinder. • The heat pump can be used in modernisation projects as high flow temperatures of up to 75 °C are available all year round for room heating and DHW heating. • The integral heat pump manager enables fully automatic, weather-compensated control of the heating system. • High efficiency circulation pumps and expansion vessels are provided for both the brine side and the heating side. • An insulated pump assembly supplies the heat distribution system.Benefits Mono mode operation possible for heating and DHW thanks to higher flow temperatures Inverter technology allows ideally matched heating output through the variable speed compressor Easy and time saving installation, due to high level of integration and inclusion of accessories Buffer cylinder to separate the flows for maximum operational reliability Separate DHW cylinder for a high level of hot water convenience4 | 5

Page 5

Our domestic ground source packs with a passive cooling option (does not require compressor to start – works simply with moving the heat from your home with your circulating pumps). Every pack comes with a 100 litre buffer and a 290 litre DHW cylinder. Simply choose the correctly sized heat pump for the your project.Set of components WPE-I 04-15 HK 230 Premium Pack1 Type WPE-I HK 230 (size dependent on pack chosen) Quantity 1 Product Ground source heat pump2 Type SBP 100 classic Quantity 1 Product Buffer cylinder3 Type SBB 300 Trend Quantity 1 Product DHW cylinder4 Type WPSF Quantity 1 Product WPSF multifunction brine filling unit5 Type FS-WP 28 Quantity 2 Product Filter sets6 Type WPKI-HK ME Quantity 1 Product Heating circuit assembly for heating circuit without mixer7 Type UP 25-60 B Quantity 1 Product Circulation pump for external DHW heating8 Type FET Quantity 1 ProductDigital remote control9TypeISG web Quantity 1 Product Internet Service Gateway10 Type TAF PT 2m Quantity 2 (*1) Product Immersion/contact sensorWPE-I 04 HK 230 Premium PackWPE-I 06 HK 230 Premium PackWPE-I 08 HK 230 Premium PackWPE-I 12 HK 230 Premium PackWPE-I 15 HK 230 Premium Pack Part number 204399 204405 204402 204407 204404See more detailsof each packApplication • This ground source heat pump with output-dependent control and inverter technology is installed indoors and combined with a separate buffer and DHW cylinder. • The heat pump can be used in modernisation projects as high flow temperatures of up to 75 °C are available all year round for room heating and DHW heating. • The integral heat pump manager enables fully automatic, weather-compensated control of the heating system. • High efficiency circulation pumps and expansion vessels are provided for both the brine side and the heating side. • An insulated pump assembly supplies the heat distribution system.Benefits Mono mode operation possible for heating and DHW thanks to higher flow temperatures Inverter technology allows ideally matched heating output through the variable speed compressor Easy and time saving installation, due to high level of integration and inclusion of accessories Buffer cylinder to separate the flows for maximum operational reliability Separate DHW cylinder for a high level of hot water convenience4 | 5

Page 6

Our domestic ground source packs with DHW tanks built into the heat pump unit for heating only. Every pack comes with a 100 litre buffer. Simply choose the correctly sized heat pump for the your project (04-08 feature 175 litre built in DHW cylinders whilst 12 and 15 have 162 litres).Application • This compact ground source heat pump with output-dependent control and inverter technology is installed indoors. It has an integral DHW cylinder and is combined with a separate buffer cylinder. • Thanks to the very high flow temperatures of up to 75 °C, the heat pump can be used in both new build and modernisation.A heat pump controller is integrated for fully automatic, weather-compensated control of the heating system. • Both the brine and heating sides are equipped with a high efficiency circulation pump. • An insulated pump assembly supplies the heat distribution system.Benefits Mono mode operation possible for heating and DHW thanks to higher flow temperatures Inverter technology allows ideally matched heating output through the variable speed compressor Easy and time saving installation, due to high level of integration and inclusion of accessories Easy to transport as the refrigerant circuit and cylinder module can be separated from one another and are fitted with integral carrying handles Buffer cylinder to separate the flows for maximum operational reliabilityWPE-I 04 HW 230 GB Premium PackWPE-I 06 HW 230 GB Premium PackWPE-I 08 HW 230 GB Premium PackWPE-I 12 HW 230 GB Premium PackWPE-I 15 HW 230 GB Premium PackPart number 204400 204406 204401 204403 204408See more detailsof each packSet of components WPE-I 04-15 HW 230 GB Premium Pack1 Type WPE-I HW 230 (size dependent on pack chosen) Quantity 1 Product Ground source heat pump2 Type SBP 100 classic Quantity 1 Product Buffer cylinder3 Type WPSF Quantity 1 Product WPSF multifunction brine filling unit4 Type FS-WP 22 Quantity 1 Product Filter sets5 Type WPKI-HK E Quantity 1 Product Heating circuit assembly for heating circuit without mixer6 Type FET Quantity 1 ProductDigital remote control7TypeISG web Quantity 1 Product Internet Service Gateway6 | 7

Page 7

Our domestic ground source packs with DHW tanks built into the heat pump unit for heating only. Every pack comes with a 100 litre buffer. Simply choose the correctly sized heat pump for the your project (04-08 feature 175 litre built in DHW cylinders whilst 12 and 15 have 162 litres).Application • This compact ground source heat pump with output-dependent control and inverter technology is installed indoors. It has an integral DHW cylinder and is combined with a separate buffer cylinder. • Thanks to the very high flow temperatures of up to 75 °C, the heat pump can be used in both new build and modernisation.A heat pump controller is integrated for fully automatic, weather-compensated control of the heating system. • Both the brine and heating sides are equipped with a high efficiency circulation pump. • An insulated pump assembly supplies the heat distribution system.Benefits Mono mode operation possible for heating and DHW thanks to higher flow temperatures Inverter technology allows ideally matched heating output through the variable speed compressor Easy and time saving installation, due to high level of integration and inclusion of accessories Easy to transport as the refrigerant circuit and cylinder module can be separated from one another and are fitted with integral carrying handles Buffer cylinder to separate the flows for maximum operational reliabilityWPE-I 04 HW 230 GB Premium PackWPE-I 06 HW 230 GB Premium PackWPE-I 08 HW 230 GB Premium PackWPE-I 12 HW 230 GB Premium PackWPE-I 15 HW 230 GB Premium PackPart number 204400 204406 204401 204403 204408See more detailsof each packSet of components WPE-I 04-15 HW 230 GB Premium Pack1 Type WPE-I HW 230 (size dependent on pack chosen) Quantity 1 Product Ground source heat pump2 Type SBP 100 classic Quantity 1 Product Buffer cylinder3 Type WPSF Quantity 1 Product WPSF multifunction brine filling unit4 Type FS-WP 22 Quantity 1 Product Filter sets5 Type WPKI-HK E Quantity 1 Product Heating circuit assembly for heating circuit without mixer6 Type FET Quantity 1 ProductDigital remote control7TypeISG web Quantity 1 Product Internet Service Gateway6 | 7

Page 8

8 | 9Pack for heating only (no cooling) with highly compact and lightweight stainless steel 225 litre DHW cylinder, ideal for tting into tight spaces.Application • This mono block heat pump with output-dependent control, with highly integrated indoor module, is suitable for fast, space saving installation. • Flow temperatures of up to 75 °C are available for room heating and DHW heating. • It can be used in a wide range of different heat distribution systems, as the heat pump is separated from the heat distribution system by means of an integral buffer cylinder. • The indoor module also contains the following components: DHW cylinder, cylinder charging pump, circulation pump, 3/2-way diverter valve, safety valve, electric emergency/auxiliary heater and the heat pump manager, which is used to control the system.Benefits Air source heat pump set for maximum efficiency in new build or modernisation Mono block heat pump, with its variable speed compressors, ensures perfectly matched heating output and high flow temperatures all year round DHW cylinder and buffer cylinder with integral hydraulic components including heat pump manager for heat pumps and heating circuit connection in a single casing Thanks to flow separation, the heating system can be integrated easily and very safelyWPL-A 07 HK Premium Compact SetPart number 206044See more details of packSet of components WPL-A 07 HK Premium Compact Set1 Type WPL-A 07 HK 230 Premium Quantity 1 Product Air source heat pump2 Type HSBC 225 S 1 Quantity 1 Product Integral cylinder3 Type FS-WP 28 Quantity 1 Product Filter sets4 Type FET Quantity 1 ProductDigital remote control5TypeISG web Quantity 1 Product Internet Service GatewayPack for heating and active cooling with compressor via underoor systems (for systems designed to run above dewpoint) with 200 litre DHW cylinder and buffer tank in one integrated unit.Application • This mono block heat pump with output-dependent control and highly integrated indoor module is suitable for fast, space saving installation. • Flow temperatures of up to 75 °C are available for room heating and DHW heating. • It can be used in a wide range of different heat distribution systems, as the heat pump is separated from the heat distribution system by means of an integral buffer cylinder. • The indoor module contains the following components: DHW cylinder, cylinder charging pump, circulation pump, 3/2-way diverter valve, safety valve, electric emergency/auxiliary heater and the heat pump manager, which is used to control the system.Benefits Air source heat pump set for maximum efficiency in new build or modernisation Mono block heat pump, with its variable speed compressors, ensures perfectly matched heating output and high flow temperatures all year round DHW cylinder and buffer cylinder with integral hydraulic components including heat pump manager for heat pumps and heating circuit connection in a single casing Thanks to flow separation, the heating system can be integrated easily and very safelyWPL-A 07 Premium Pack HSBC 200 Part number 204906See more details of packSet of components WPL-A 07 Premium Pack HSBC 2001 Type WPL-A 07 HK 230 Premium Quantity 1 Product Air source heat pump1 Type HSBC 200 S (GB) Set Quantity 1 Product Integral cylinder2 Type FS-WP 28 Quantity 1 Product Filter sets3 Type FET Quantity 1 ProductDigital remote control4TypeISG web Quantity 1 Product Internet Service Gateway

Page 9

8 | 9Pack for heating only (no cooling) with highly compact and lightweight stainless steel 225 litre DHW cylinder, ideal for tting into tight spaces.Application • This mono block heat pump with output-dependent control, with highly integrated indoor module, is suitable for fast, space saving installation. • Flow temperatures of up to 75 °C are available for room heating and DHW heating. • It can be used in a wide range of different heat distribution systems, as the heat pump is separated from the heat distribution system by means of an integral buffer cylinder. • The indoor module also contains the following components: DHW cylinder, cylinder charging pump, circulation pump, 3/2-way diverter valve, safety valve, electric emergency/auxiliary heater and the heat pump manager, which is used to control the system.Benefits Air source heat pump set for maximum efficiency in new build or modernisation Mono block heat pump, with its variable speed compressors, ensures perfectly matched heating output and high flow temperatures all year round DHW cylinder and buffer cylinder with integral hydraulic components including heat pump manager for heat pumps and heating circuit connection in a single casing Thanks to flow separation, the heating system can be integrated easily and very safelyWPL-A 07 HK Premium Compact SetPart number 206044See more details of packSet of components WPL-A 07 HK Premium Compact Set1 Type WPL-A 07 HK 230 Premium Quantity 1 Product Air source heat pump2 Type HSBC 225 S 1 Quantity 1 Product Integral cylinder3 Type FS-WP 28 Quantity 1 Product Filter sets4 Type FET Quantity 1 ProductDigital remote control5TypeISG web Quantity 1 Product Internet Service GatewayPack for heating and active cooling with compressor via underoor systems (for systems designed to run above dewpoint) with 200 litre DHW cylinder and buffer tank in one integrated unit.Application • This mono block heat pump with output-dependent control and highly integrated indoor module is suitable for fast, space saving installation. • Flow temperatures of up to 75 °C are available for room heating and DHW heating. • It can be used in a wide range of different heat distribution systems, as the heat pump is separated from the heat distribution system by means of an integral buffer cylinder. • The indoor module contains the following components: DHW cylinder, cylinder charging pump, circulation pump, 3/2-way diverter valve, safety valve, electric emergency/auxiliary heater and the heat pump manager, which is used to control the system.Benefits Air source heat pump set for maximum efficiency in new build or modernisation Mono block heat pump, with its variable speed compressors, ensures perfectly matched heating output and high flow temperatures all year round DHW cylinder and buffer cylinder with integral hydraulic components including heat pump manager for heat pumps and heating circuit connection in a single casing Thanks to flow separation, the heating system can be integrated easily and very safelyWPL-A 07 Premium Pack HSBC 200 Part number 204906See more details of packSet of components WPL-A 07 Premium Pack HSBC 2001 Type WPL-A 07 HK 230 Premium Quantity 1 Product Air source heat pump1 Type HSBC 200 S (GB) Set Quantity 1 Product Integral cylinder2 Type FS-WP 28 Quantity 1 Product Filter sets3 Type FET Quantity 1 ProductDigital remote control4TypeISG web Quantity 1 Product Internet Service Gateway

Page 10

Pack for heating and active cooling with compressor via underoor systems or fancoil radiators (for systems designed to run below dewpoint) with 300 litre DHW cylinder and separate 100 ltr buffer tank.Benefits Air source heat pump set for maximum efficiency in new build or modernisation Mono block heat pump, with its variable speed compressors, ensures perfectly matched heating output and high flow temperatures all year round Separate buffer cylinder for separation of flow rates for maximum operational reliability High hot water convenience due to separate DHW cylinderWPL-A 07 Premium Pack SBP | SBB Part number 204908See more details of packSet of components WPL-A 07 Premium Pack SBP | SBB1 Type WPL-A 07 HK 230 Premium Quantity 1 Product Air source heat pump2 Type SBP 100 classic Quantity 1 Product Buffer cylinder3 Type SBB 300 Trend Quantity 1 Product DHW cylinder4 Type WPM Quantity 1 Product Heat pump manager in wall mounted enclosure5 Type UP 25/7.5 PCV Quantity 2Product Heating circuit pump6 Type FS-WP 28 Quantity 2 Product Filter sets7 Type WPKI-HK EQuantity 1 Product Heating circuit assembly for heating circuit without mixer8 Type FETQuantity 1 Product Digital remote control9 Type ISG webQuantity 1 Product Internet Service GatewayApplication • This mono block heat pump with output-dependent control is combined with a separate buffer cylinder and a DHW cylinder. • Flow temperatures of up to 75 °C are available for room heating and DHW heating. • The wall mounted heat pump manager controls the appliance. • Flow separation is achieved by means of the buffer cylinder. • An insulated pump assembly supplies the heat distribution system.10 | 11Pack for heating and active cooling with compressor via underoor systems or fancoil radiators (for systems designed to run below dewpoint) with 300 litre DHW cylinder and buffer tank in one integrated unit.Application • This mono block heat pump with output-dependent control, with highly integrated indoor module, is suitable for fast, space saving installation. • Flow temperatures of up to 75 °C are available for room heating and DHW heating. • High hot water convenience. • It can be used in a wide range of different heat distribution systems, as the heat pump is separated from the heat distribution system by means of an integral buffer cylinder. • The indoor module also contains the following components: DHW cylinder, cylinder charging pump, circulation pump, 3/2-way diverter valve, electric emergency/auxiliary heater and the heat pump manager, which is used to control the system.Benefits The integral WPM heat pump manager makes the system easier to install Air source heat pump set for maximum efficiency in new build or modernisation Mono block heat pump, with its variable speed compressors, ensures perfectly matched heating output and high flow temperatures all year round DHW cylinder and buffer cylinder with integral hydraulic components including heat pump manager for heat pumps and heating circuit connection in a single casingWPL-A 07 Premium Pack HSBC 300Part number 204907See more details of packSet of components WPL-A 07 Premium Pack HSBC 3001 Type WPL-A 07 HK 230 Premium Quantity 1 Product Air source heat pump2 Type HSBC 300 cool (GB) Set Quantity 1 Product Integral cylinder3 Type FS-WP 28 Quantity 1 Product Filter sets4 Type FET Quantity 1 ProductDigital remote control5TypeISG web Quantity 1 Product Internet Service Gateway

Page 11

Pack for heating and active cooling with compressor via underoor systems or fancoil radiators (for systems designed to run below dewpoint) with 300 litre DHW cylinder and separate 100 ltr buffer tank.Benefits Air source heat pump set for maximum efficiency in new build or modernisation Mono block heat pump, with its variable speed compressors, ensures perfectly matched heating output and high flow temperatures all year round Separate buffer cylinder for separation of flow rates for maximum operational reliability High hot water convenience due to separate DHW cylinderWPL-A 07 Premium Pack SBP | SBB Part number 204908See more details of packSet of components WPL-A 07 Premium Pack SBP | SBB1 Type WPL-A 07 HK 230 Premium Quantity 1 Product Air source heat pump2 Type SBP 100 classic Quantity 1 Product Buffer cylinder3 Type SBB 300 Trend Quantity 1 Product DHW cylinder4 Type WPM Quantity 1 Product Heat pump manager in wall mounted enclosure5 Type UP 25/7.5 PCV Quantity 2Product Heating circuit pump6 Type FS-WP 28 Quantity 2 Product Filter sets7 Type WPKI-HK EQuantity 1 Product Heating circuit assembly for heating circuit without mixer8 Type FETQuantity 1 Product Digital remote control9 Type ISG webQuantity 1 Product Internet Service GatewayApplication • This mono block heat pump with output-dependent control is combined with a separate buffer cylinder and a DHW cylinder. • Flow temperatures of up to 75 °C are available for room heating and DHW heating. • The wall mounted heat pump manager controls the appliance. • Flow separation is achieved by means of the buffer cylinder. • An insulated pump assembly supplies the heat distribution system.10 | 11Pack for heating and active cooling with compressor via underoor systems or fancoil radiators (for systems designed to run below dewpoint) with 300 litre DHW cylinder and buffer tank in one integrated unit.Application • This mono block heat pump with output-dependent control, with highly integrated indoor module, is suitable for fast, space saving installation. • Flow temperatures of up to 75 °C are available for room heating and DHW heating. • High hot water convenience. • It can be used in a wide range of different heat distribution systems, as the heat pump is separated from the heat distribution system by means of an integral buffer cylinder. • The indoor module also contains the following components: DHW cylinder, cylinder charging pump, circulation pump, 3/2-way diverter valve, electric emergency/auxiliary heater and the heat pump manager, which is used to control the system.Benefits The integral WPM heat pump manager makes the system easier to install Air source heat pump set for maximum efficiency in new build or modernisation Mono block heat pump, with its variable speed compressors, ensures perfectly matched heating output and high flow temperatures all year round DHW cylinder and buffer cylinder with integral hydraulic components including heat pump manager for heat pumps and heating circuit connection in a single casingWPL-A 07 Premium Pack HSBC 300Part number 204907See more details of packSet of components WPL-A 07 Premium Pack HSBC 3001 Type WPL-A 07 HK 230 Premium Quantity 1 Product Air source heat pump2 Type HSBC 300 cool (GB) Set Quantity 1 Product Integral cylinder3 Type FS-WP 28 Quantity 1 Product Filter sets4 Type FET Quantity 1 ProductDigital remote control5TypeISG web Quantity 1 Product Internet Service Gateway

Page 12

12 | 13Pack for heating only (no cooling) with 220 litre compact stainless steel system DHW cylinder.Application • This air source heat pump with output-dependent control is combined with an integral cylinder. The set includes the heat pump for outdoor installation, an internal integral cylinder and all the hydraulic connection components for the heating installation. • In addition to the integral cylinder, standard delivery also includes the circulation pump, 3/2-way diverter valve and safety valve. • Control is provided by the integral heat pump manager.Benefits The air source heat pump is ideally suited to new builds Simple operation through integrated heat pump manager The mono block heat pump is installed outdoors and its variable speed compressor ensures perfectly matched heating output Small footprint as just one indoor and outdoor unit is required DHW cylinder and buffer cylinder with integral hydraulic components including heat pump manager for heat pumps and heating circuit connection in a single casingSet of components HPA-O 8 CS Plus int Compact Set1 Type HPA-O 8 CS Plus int Quantity 1 Product Air source heat pump2 Type HSBC 220 Quantity 1 Product Integral cylinder3 Type FS-WP 22 Quantity 1 Product Filter sets4 Type FET Quantity 1 ProductDigital remote control5TypeISG web Quantity 1 Product Internet Service GatewayHPA-O 8 CS Plus int Compact Set Part number 206043See more details of packNOTE: must be mounted on feet or wall bracket, to be chosen when you place the orderPack for heating only (no cooling) with 225 litre compact stainless steel system DHW cylinder.Application • This mono block heat pump with output-dependent control and highly integrated indoor module is suitable for fast, space saving installation. It can be used for renovation projects as flow temperatures of up to 65 °C are available all year round for heating and DHW heating. • High DHW convenience. • It can be used in a wide range of different heat distribution systems, as the heat pump is separated from the heat distribution system by means of an integral buffer cylinder. • The indoor module also contains the following components: DHW cylinder, cylinder charging pump, circulation pump, 3/2-way diverter valve, electric emergency/auxiliary heater and the heat pump manager, which is used to control the system.Benefits Large DHW cylinder and buffer cylinder with integral hydraulic components for heat pumps and heating circuit connection in a single casing The integral WPM heat pump manager makes the system easier to install Air source heat pump set for maximum efficiency in new build or modernisation Mono block heat pump, with its variable speed compressors, ensures perfectly matched heating output and high flow temperatures all year roundWPL 25 ACS Compact Set Part number 206042See more detailsof each packSet of components WPL 25 ACS Compact Set1 Type WPL 25 ACS Quantity 1 Product Air source heat pump2 Type HSBC 225 S 1 Quantity 1 Product Integral cylinder3 Type FS-WP 28 Quantity 1 Product Filter sets4 Type FET Quantity 1 ProductDigital remote control5TypeISG web Quantity 1 Product Internet Service Gateway

Page 13

12 | 13Pack for heating only (no cooling) with 220 litre compact stainless steel system DHW cylinder.Application • This air source heat pump with output-dependent control is combined with an integral cylinder. The set includes the heat pump for outdoor installation, an internal integral cylinder and all the hydraulic connection components for the heating installation. • In addition to the integral cylinder, standard delivery also includes the circulation pump, 3/2-way diverter valve and safety valve. • Control is provided by the integral heat pump manager.Benefits The air source heat pump is ideally suited to new builds Simple operation through integrated heat pump manager The mono block heat pump is installed outdoors and its variable speed compressor ensures perfectly matched heating output Small footprint as just one indoor and outdoor unit is required DHW cylinder and buffer cylinder with integral hydraulic components including heat pump manager for heat pumps and heating circuit connection in a single casingSet of components HPA-O 8 CS Plus int Compact Set1 Type HPA-O 8 CS Plus int Quantity 1 Product Air source heat pump2 Type HSBC 220 Quantity 1 Product Integral cylinder3 Type FS-WP 22 Quantity 1 Product Filter sets4 Type FET Quantity 1 ProductDigital remote control5TypeISG web Quantity 1 Product Internet Service GatewayHPA-O 8 CS Plus int Compact Set Part number 206043See more details of packNOTE: must be mounted on feet or wall bracket, to be chosen when you place the orderPack for heating only (no cooling) with 225 litre compact stainless steel system DHW cylinder.Application • This mono block heat pump with output-dependent control and highly integrated indoor module is suitable for fast, space saving installation. It can be used for renovation projects as flow temperatures of up to 65 °C are available all year round for heating and DHW heating. • High DHW convenience. • It can be used in a wide range of different heat distribution systems, as the heat pump is separated from the heat distribution system by means of an integral buffer cylinder. • The indoor module also contains the following components: DHW cylinder, cylinder charging pump, circulation pump, 3/2-way diverter valve, electric emergency/auxiliary heater and the heat pump manager, which is used to control the system.Benefits Large DHW cylinder and buffer cylinder with integral hydraulic components for heat pumps and heating circuit connection in a single casing The integral WPM heat pump manager makes the system easier to install Air source heat pump set for maximum efficiency in new build or modernisation Mono block heat pump, with its variable speed compressors, ensures perfectly matched heating output and high flow temperatures all year roundWPL 25 ACS Compact Set Part number 206042See more detailsof each packSet of components WPL 25 ACS Compact Set1 Type WPL 25 ACS Quantity 1 Product Air source heat pump2 Type HSBC 225 S 1 Quantity 1 Product Integral cylinder3 Type FS-WP 28 Quantity 1 Product Filter sets4 Type FET Quantity 1 ProductDigital remote control5TypeISG web Quantity 1 Product Internet Service Gateway

Page 14

14 | 15Pack with 300 litre system cylinder with integral buffer tank. Pack for heating and active cooling with compressor via underoor systems or fancoil radiators (for systems designed to run below dewpoint).Application • This mono block heat pump with output-dependent control, with highly integrated indoor module, is suitable for fast, space saving installation. • Flow temperatures of up to 75 °C are available for room heating and DHW heating. • High hot water convenience. • It can be used in a wide range of different heat distribution systems, as the heat pump is separated from the heat distribution system by means of an integral buffer cylinder. • The indoor module also contains the following components: DHW cylinder, cylinder charging pump, circulation pump, 3/2-way diverter valve, electric emergency/auxiliary heater and the heat pump manager, which is used to control the system.Benefits The integral WPM heat pump manager makes the system easier to install Air source heat pump set for maximum efficiency in new build or modernisation Mono block heat pump, with its variable speed compressors, ensures perfectly matched heating output and high flow temperatures all year round DHW cylinder and buffer cylinder with integral hydraulic components including heat pump manager for heat pumps and heating circuit connection in a single casingWPL Plus Pack 2Part number 204912See more detailsof each packSet of components WPL Plus Pack 21 Type WPL 25 ACS Quantity 1 Product Air source heat pump2 Type HSBC 300 cool (GB) Set Quantity 1 Product Integral cylinder3 Type FS-WP 28 (filter) Quantity 1 Product Filter sets4 Type FET Quantity 1 ProductDigital remote control5TypeISG web Quantity 1 Product Internet Service GatewayPack for heating and active cooling with compressor via underoor systems (for systems designed to run above dewpoint) with 200 litre compact DHW cylinder.Application • This mono block heat pump with output-dependent control, with highly integrated indoor module, is suitable for fast, space saving installation. • It can be used in modernisation projects as flow temperatures of up to 65 °C are available all year round for room heating and DHW heating. • It can be used in a wide range of different heat distribution systems, as the heat pump is separated from the heat distribution system by means of an integral buffer cylinder. • The indoor module also contains the following components: DHW cylinder, cylinder charging pump, circulation pump, 3/2-way diverter valve, safety valve, electric emergency/auxiliary heater and the heat pump manager, which is used to control the system.Benefits Air source heat pump set for maximum efficiency in new build or modernisation Mono block heat pump, with its variable speed compressors, ensures perfectly matched heating output and high flow temperatures all year round DHW cylinder and buffer cylinder with integral hydraulic components including heat pump manager for heat pumps and heating circuit connection in a single casing Thanks to flow separation, the heating system can be integrated easily and very safelySet of components WPL Plus Pack 11 Type WPL 25 ACS Quantity 1 Product Air source heat pump2 Type HSBC 200 S (GB) Set Quantity 1 Product Integral cylinder3 Type FS-WP 28 Quantity 1 Product Filter sets4 Type FET Quantity 1 ProductDigital remote control5TypeISG web Quantity 1 Product Internet Service GatewayWPL Plus Pack 1 Part number 204911See more details of pack

Page 15

14 | 15Pack with 300 litre system cylinder with integral buffer tank. Pack for heating and active cooling with compressor via underoor systems or fancoil radiators (for systems designed to run below dewpoint).Application • This mono block heat pump with output-dependent control, with highly integrated indoor module, is suitable for fast, space saving installation. • Flow temperatures of up to 75 °C are available for room heating and DHW heating. • High hot water convenience. • It can be used in a wide range of different heat distribution systems, as the heat pump is separated from the heat distribution system by means of an integral buffer cylinder. • The indoor module also contains the following components: DHW cylinder, cylinder charging pump, circulation pump, 3/2-way diverter valve, electric emergency/auxiliary heater and the heat pump manager, which is used to control the system.Benefits The integral WPM heat pump manager makes the system easier to install Air source heat pump set for maximum efficiency in new build or modernisation Mono block heat pump, with its variable speed compressors, ensures perfectly matched heating output and high flow temperatures all year round DHW cylinder and buffer cylinder with integral hydraulic components including heat pump manager for heat pumps and heating circuit connection in a single casingWPL Plus Pack 2Part number 204912See more detailsof each packSet of components WPL Plus Pack 21 Type WPL 25 ACS Quantity 1 Product Air source heat pump2 Type HSBC 300 cool (GB) Set Quantity 1 Product Integral cylinder3 Type FS-WP 28 (filter) Quantity 1 Product Filter sets4 Type FET Quantity 1 ProductDigital remote control5TypeISG web Quantity 1 Product Internet Service GatewayPack for heating and active cooling with compressor via underoor systems (for systems designed to run above dewpoint) with 200 litre compact DHW cylinder.Application • This mono block heat pump with output-dependent control, with highly integrated indoor module, is suitable for fast, space saving installation. • It can be used in modernisation projects as flow temperatures of up to 65 °C are available all year round for room heating and DHW heating. • It can be used in a wide range of different heat distribution systems, as the heat pump is separated from the heat distribution system by means of an integral buffer cylinder. • The indoor module also contains the following components: DHW cylinder, cylinder charging pump, circulation pump, 3/2-way diverter valve, safety valve, electric emergency/auxiliary heater and the heat pump manager, which is used to control the system.Benefits Air source heat pump set for maximum efficiency in new build or modernisation Mono block heat pump, with its variable speed compressors, ensures perfectly matched heating output and high flow temperatures all year round DHW cylinder and buffer cylinder with integral hydraulic components including heat pump manager for heat pumps and heating circuit connection in a single casing Thanks to flow separation, the heating system can be integrated easily and very safelySet of components WPL Plus Pack 11 Type WPL 25 ACS Quantity 1 Product Air source heat pump2 Type HSBC 200 S (GB) Set Quantity 1 Product Integral cylinder3 Type FS-WP 28 Quantity 1 Product Filter sets4 Type FET Quantity 1 ProductDigital remote control5TypeISG web Quantity 1 Product Internet Service GatewayWPL Plus Pack 1 Part number 204911See more details of pack

Page 16

16 | 17WPL Plus Pack 4 Part number 204914See more details of packSet of components WPL Plus Pack 41 Type WPL 25 ACS Quantity 1 Product Air source heat pump2 Type STH 210 Plus Quantity 1 Product Buffer cylinder3 Type SBB 300 Trend Quantity 1 Product DHW cylinder4 Type WPM Quantity 1 Product Heat pump manager in wall mounted enclosure5 Type WPKI-HK E Quantity 1 Product Heating circuit assembly for heating circuit without mixer6 Type UP 25/7.5 PCV Quantity 2 Product Heating circuit pump7 Type FS-WP 28 Quantity 1 Product Filter sets8 Type WPKI 5-I Quantity 1 Product Pipe set9 Type BBI 5 Quantity 1 Product Pipe set10 Type FET Quantity 1 Product Digital remote control11 Type ISG web Quantity 1 Product Internet Service GatewayPack for heating and active cooling with compressor via underoor systems or fancoil radiators (for systems designed to run below dewpoint) with 300 litre DHW cylinder and separate 200 ltr buffer tank.Application • This mono block heat pump with output-dependent control delivers high flow temperatures all year round and is delivered in combination with a separate buffer cylinder and a large DHW cylinder. • The wall mounted heat pump manager controls the appliance. • The buffer cylinder is used to separate the flows. • An insulated pump assembly supplies the heat distribution system.Benefits Separate buffer cylinder for separation of flow rates for maximum operational reliability High hot water convenience due to separate DHW cylinder Air source heat pump set for maximum efficiency in new build or modernisation Mono block heat pump, with its variable speed compressors, ensures perfectly matched heating output and high flow temperatures all year roundPack for heating and active cooling with compressor via underoor systems or fancoil radiators (for systems designed to run below dewpoint) with 300 litre DHW cylinder and separate 100 ltr buffer tank.Application • This mono block heat pump with output-dependent control delivers high flow temperatures all year round in combination with a separate buffer cylinder and DHW cylinder. • The wall mounted heat pump manager controls the appliance. • A buffer cylinder for separating the flows is included. • The heat distribution system is supplied via an insulated pump assembly.Benefits Separate buffer cylinder for separation of flow rates for maximum operational reliability High hot water convenience due to separate DHW cylinder Air source heat pump set for maximum efficiency in new build or modernisation Mono block heat pump, with its variable speed compressors, ensures perfectly matched heating output and high flow temperatures all year roundWPL Plus Pack 3Part number 204913See more details of packSet of components WPL Plus Pack 31 Type WPL 25 ACS Quantity 1 Product Air source heat pump2 Type SBP 100 classic Quantity 1 Product Buffer cylinder3 Type SBB 300 Trend Quantity 1 Product DHW cylinder4 Type WPM Quantity 1 Product Heat pump manager in wall mounted enclosure5 Type WPKI-HK E Quantity 1 Product Heating circuit assembly for heating circuit without mixer6 Type UP 25/7.5 PCV Quantity 2 Product Heating circuit pump7 Type FS-WP 28 Quantity 1 Product Filter sets8 Type FET Quantity 1 Product Digital remote control9 Type ISG web Quantity 1 Product Internet Service Gateway

Page 17

16 | 17WPL Plus Pack 4 Part number 204914See more details of packSet of components WPL Plus Pack 41 Type WPL 25 ACS Quantity 1 Product Air source heat pump2 Type STH 210 Plus Quantity 1 Product Buffer cylinder3 Type SBB 300 Trend Quantity 1 Product DHW cylinder4 Type WPM Quantity 1 Product Heat pump manager in wall mounted enclosure5 Type WPKI-HK E Quantity 1 Product Heating circuit assembly for heating circuit without mixer6 Type UP 25/7.5 PCV Quantity 2 Product Heating circuit pump7 Type FS-WP 28 Quantity 1 Product Filter sets8 Type WPKI 5-I Quantity 1 Product Pipe set9 Type BBI 5 Quantity 1 Product Pipe set10 Type FET Quantity 1 Product Digital remote control11 Type ISG web Quantity 1 Product Internet Service GatewayPack for heating and active cooling with compressor via underoor systems or fancoil radiators (for systems designed to run below dewpoint) with 300 litre DHW cylinder and separate 200 ltr buffer tank.Application • This mono block heat pump with output-dependent control delivers high flow temperatures all year round and is delivered in combination with a separate buffer cylinder and a large DHW cylinder. • The wall mounted heat pump manager controls the appliance. • The buffer cylinder is used to separate the flows. • An insulated pump assembly supplies the heat distribution system.Benefits Separate buffer cylinder for separation of flow rates for maximum operational reliability High hot water convenience due to separate DHW cylinder Air source heat pump set for maximum efficiency in new build or modernisation Mono block heat pump, with its variable speed compressors, ensures perfectly matched heating output and high flow temperatures all year roundPack for heating and active cooling with compressor via underoor systems or fancoil radiators (for systems designed to run below dewpoint) with 300 litre DHW cylinder and separate 100 ltr buffer tank.Application • This mono block heat pump with output-dependent control delivers high flow temperatures all year round in combination with a separate buffer cylinder and DHW cylinder. • The wall mounted heat pump manager controls the appliance. • A buffer cylinder for separating the flows is included. • The heat distribution system is supplied via an insulated pump assembly.Benefits Separate buffer cylinder for separation of flow rates for maximum operational reliability High hot water convenience due to separate DHW cylinder Air source heat pump set for maximum efficiency in new build or modernisation Mono block heat pump, with its variable speed compressors, ensures perfectly matched heating output and high flow temperatures all year roundWPL Plus Pack 3Part number 204913See more details of packSet of components WPL Plus Pack 31 Type WPL 25 ACS Quantity 1 Product Air source heat pump2 Type SBP 100 classic Quantity 1 Product Buffer cylinder3 Type SBB 300 Trend Quantity 1 Product DHW cylinder4 Type WPM Quantity 1 Product Heat pump manager in wall mounted enclosure5 Type WPKI-HK E Quantity 1 Product Heating circuit assembly for heating circuit without mixer6 Type UP 25/7.5 PCV Quantity 2 Product Heating circuit pump7 Type FS-WP 28 Quantity 1 Product Filter sets8 Type FET Quantity 1 Product Digital remote control9 Type ISG web Quantity 1 Product Internet Service Gateway

Page 18

18 | 19Area Specification Manager Telephone EmailScotland Simon Gray 07866 070018 simon.gray@stiebel-eltron.co.ukNorth Central Oliver Gledhill 07929 724682 oliver.gledhill@stiebel-eltron.co.ukNorth West / North Wales Stuart Galloway 07894 483840 stuart.galloway@stiebel-eltron.co.ukNorth East Nick Maddison 07977 358732 nick.maddison@stiebel-eltron.co.ukMidlands George Hiley 07890 416 508 george.hiley@stiebel-eltron.co.ukMidlands East Tony Preston 07894 483835 tony.preston@stiebel-eltron.co.ukMidlands West Jack Hiley 07929 724618 jack.hiley@stiebel-eltron.co.ukSouth Wales Richard Hopkins 07894 483837 richard.hopkins@stiebel-eltron.co.ukSouth West Stewart Ratcliff 07890 416 380 stewart.ratcliff@stiebel-eltron.co.ukSouth East / London Nick Underwood 07866 069957 nick.underwood@stiebel-eltron.co.ukArea Regional Service Manager Technical SupportScotland Alister TetsillTelephone0151 346 2301 or emailtechnical@stiebel-eltron.co.ukNorth Central Wallace ChungaNorth West / North Wales Dean FallowsNorth East Ian MilnerMidlands Ashley ThursfieldMidlands East Ian ColemanMidlands West Mark CableSouth Wales Kelvin GallagherSouth West Rob YoungSouth East / London Andy ProbertWe have nationwide eld sales and technical support for your business. Alongside our head-ofce sales and technical teams every region in the UK has a dedicated local team that you can call on for project help at every stage. Find your sales contact now!www.stiebel-eltron.co.uk/ndyourlocalsalesmanagerBHSPPLEXTATQDTTRBAJEGYNPCFSALDGLSNBSHRSYWRWVDEDYTFSWSSTBIMLLLLPRBBSKCWLWNCHMLAFYOLBLWAZEHSKWGDGABPHIVTDFKMLEHDDPAKYKANEHGLSBDHDWFHXSRDHDLCAHUYOLNNGTSDNIPCBPELENROXCOLUCVNNMKSGCMHPALSOTNCTBNGUSSRHPORGMEIGSMCRKTSEEWCECSWHAWDBRNNWWTWUBRMDAENSLKey Scotland North Central North West / North Wales North East Midlands Midlands East Midlands West South Wales South West South East / LondonLondon detail

Page 19

18 | 19Area Specification Manager Telephone EmailScotland Simon Gray 07866 070018 simon.gray@stiebel-eltron.co.ukNorth Central Oliver Gledhill 07929 724682 oliver.gledhill@stiebel-eltron.co.ukNorth West / North Wales Stuart Galloway 07894 483840 stuart.galloway@stiebel-eltron.co.ukNorth East Nick Maddison 07977 358732 nick.maddison@stiebel-eltron.co.ukMidlands George Hiley 07890 416 508 george.hiley@stiebel-eltron.co.ukMidlands East Tony Preston 07894 483835 tony.preston@stiebel-eltron.co.ukMidlands West Jack Hiley 07929 724618 jack.hiley@stiebel-eltron.co.ukSouth Wales Richard Hopkins 07894 483837 richard.hopkins@stiebel-eltron.co.ukSouth West Stewart Ratcliff 07890 416 380 stewart.ratcliff@stiebel-eltron.co.ukSouth East / London Nick Underwood 07866 069957 nick.underwood@stiebel-eltron.co.ukArea Regional Service Manager Technical SupportScotland Alister TetsillTelephone0151 346 2301 or emailtechnical@stiebel-eltron.co.ukNorth Central Wallace ChungaNorth West / North Wales Dean FallowsNorth East Ian MilnerMidlands Ashley ThursfieldMidlands East Ian ColemanMidlands West Mark CableSouth Wales Kelvin GallagherSouth West Rob YoungSouth East / London Andy ProbertWe have nationwide eld sales and technical support for your business. Alongside our head-ofce sales and technical teams every region in the UK has a dedicated local team that you can call on for project help at every stage. Find your sales contact now!www.stiebel-eltron.co.uk/ndyourlocalsalesmanagerBHSPPLEXTATQDTTRBAJEGYNPCFSALDGLSNBSHRSYWRWVDEDYTFSWSSTBIMLLLLPRBBSKCWLWNCHMLAFYOLBLWAZEHSKWGDGABPHIVTDFKMLEHDDPAKYKANEHGLSBDHDWFHXSRDHDLCAHUYOLNNGTSDNIPCBPELENROXCOLUCVNNMKSGCMHPALSOTNCTBNGUSSRHPORGMEIGSMCRKTSEEWCECSWHAWDBRNNWWTWUBRMDAENSLKey Scotland North Central North West / North Wales North East Midlands Midlands East Midlands West South Wales South West South East / LondonLondon detail

Page 20