Our full through-the-wall solution for non-loadbearing steel framing system infillGYPROC FACADE SYSTEM Message
We oer a portfolio of wraparound systems for non-loadbearing light gauge steel infill solutions to support you in this fast-moving and often complex industry.Our solutions are tested to meet 60, 90 and 120-minute fire resistance in both directions on Gyproc Facade Stud framework infill systems, and we’ll work with you to meet your thermal performance requirements. Our systems have been developed and tested with the same rigour and attention to detail that we apply to all our products and systems.
2 Introduction SYSTEMS6 120mins Fire Resistance7 T106015 (EN)8 T106022 (EN)9 T106023 (EN)10 T106030 (EN)11 T106036 (EN)12 90mins Fire Resistance13 T106021 (EN)14 T106033 (EN)15 T106034 (EN)16 T106035 (EN)18 60mins Fire Resistance19 T106019 (EN)20 T106017 (EN)21 T106018 (EN)22 T106031 (EN)23 T106032 (EN)24 Construction details30 Bespoke Solutions32 Sustainability33 Plasterboard Recycling Services34 Environmental Product Declarations35 The BREEAM® Certification36 LEED® CertificationCONTENTSGYPROC FACADE SYSTEM | 1
External Wall ConstructionIntroductionGyproc Facade System brings together Gyproc and Isover products to deliver tested fire and acoustic performances and a range of options for thermal performances on Gypframe non-loadbearing infill systems.This system has been developed and tested with the same rigour and attention to detail that we apply to all our other products and systems. Gyproc and Isover products are wrapped around the Gyproc stud framework, oering substantiated performances backed up by test evidence and technical know-how.2 | GYPROC FACADE SYSTEM
Key facts• Systems designed to oer flexible specification options• Meet and exceed thermal performance needs through a range of insulation solutions• Comprehensive fire and acoustic tested solutions• Fire resistance to BS-EN 1364-1 EI 60, 90 and 120 mins (inside to out, outside to in)• Up to Rw 56 dB tested sound insulation performance• Installation details for junctions, abutments, windows and deflection requirementsSaint-Gobain Ireland - Our approach • Our approach brings together best-in-class Gyproc and Isover products delivering tested fire, acoustic and thermal performances on Gypframe non-loadbearing infill systems. This is backed with technical specifications, guidance and advice on specific issues including junctions, abutments and deflection heads – just as we do with all our other products and systems. • Gyproc Facade System is a system that works in conjunction with Gyproc Facade Stud framework to provide a required through-wall performance. We describe these as wraparound solutions for light gauge steel infill systems, as our products are ‘wrapped around’.Infill walls The panels for infill walls are generally constructed from individual elements, which are cut to length and installed on site. The panels fit between the elements of the primary structural frame. The panels consist of a bottom track attached to the floor and a head track attached to the underside of the floor above. Vertical light steel C sections are fitted between the head and base tracks, typically at 600mm centres (or reduced to 400 or 300mm where structural design requires closer spacing). In some cases, the panels may be constructed such that they project past the edge of the primary structure.GYPROC FACADE SYSTEM | 3
ResponsibilitiesPerformance requirements of the building are the responsibility of the design team in conjunction with the contractor. Design teams will need to satisfy themselves that use of any product meets all relevant national Building Regulations and guidance as well as local, national, and other applicable standards relevant for their construction or application, including requirements in relation to fire and applicable height restrictions. Structural designGyproc and Isover Ireland, by way of our in-house design service, will work alongside design teams in the specification of a wraparound solution that will meet the specific project requirements. We would support a project with technical specifications, details and installation guidance on our products.Fire design Our wraparound solutions for non-loadbearing steel infill systems, comprise a series of components when tested together, and specified and installed as tested, can provide evidence of fire performance. There should be no substitution of components without our written approval.Direction of test External wall systems are asymmetrical and therefore the building designer should check that the fire test evidence is compliant for the project requirements, for example; fire exposure is tested from each side separately.Cavity barriers and fire breaks Cavity barriers and fire breaks must be installed in accordance with the requirements of the relevant Building Regulations. The nature of these cavity barriers and fire breaks will vary according to the design requirements of each particular project and are the responsibility of the architect in conjunction with the contractor. 4 | GYPROC FACADE SYSTEM
Fire protection of structural steel We can provide details to fully encase all structural steel. It may be possible through third-party test data (by a suitably qualified structural or fire engineer) to determine whether the conditions oered by the lining are sucient to protect hot rolled elements, without the need for additional fire protection measures. Reaction to fire The external walls of the building shall adequately resist the spread of fire over the walls and from one building to another, having regard to the height, use and position of the building. Materials which become part of an external wall, or specified attachment, of a relevant building should be of European Classification A2-s1, d0 or A1, classified in accordance with BS EN 13501-1:2007. Board linings, framing and insulation materials in Gyproc Facade System are either non-combustible (Euroclass A1) or of limited combustibility (Euroclass A2-s1-d), classified in accordance with BS EN 13501-1:2007. Membranes, seals (for example; EPDM rubber), gaskets, fixings and sealants (for example; Glasroc X Sealant) are exempt from this requirement. Cladding Tests pertaining to cladding are entirely separate with separate test standards as outlined within Approved Document guidanceThermal design The thermal performance of a building is a critical part of its performance with ever increasing scrutiny and tighter targets being given to the building’s energy eciency. Improving the energy eciency of the building will not only help save energy but will ensure that obligations towards reducing the impact of carbon emissions can be achieved. By incorporating thermal insulation into the envelope of the building both the thermal comfort of the occupants and the performance of the building can be improved. It is also possible to take this one step further and by exceeding current requirements ensure that the building will also start to meet future targets. U-values To meet the thermal requirements of the Building Regulations, it will be necessary to provide U-value calculations on the thermal performance of the system in accordance with BR 443 (2019). The facade type and its fixing detail will determine the calculation method needed for demonstration of thermal performance. We can provide advice upon which type of calculation you will require and if you contact us directly, we can work with you to find the correct specification for your project. Contact us through Technical Support at Gyproc.ieAirtightness and moisture management Dependent on factors, such as location and building type, there are specific air permeability requirements that may apply to your project. The air permeability test gives a measure of the amount of air that leaks through the building envelope and, as such, is one of the key sources of heat loss from a building. While our products and systems have been used in situations where a target air permeability rate has been met, this does not cover all possible applications. Gyproc Facade System has not been designed or tested as an air barrier and as such, we strongly recommend that guidance is sought from an air tightness specialist, who will be best placed to advise you on whether additional air seals or construction methods will be required. There are a number of factors that should be considered when determining if a breather membrane is required, including finished façade type, building location, and required air tightness performance and the design team should satisfy themselves as to the requirement of a breather membrane.Acoustic design Sound Insulation Considerations against noise should be taken at the design stage and during construction of the building. The correct acoustic climate must be provided in each space, and noise transmission levels should be compatible with the building’s usage, and external environment.InstallationThe plasterboard linings to both sides of the framework should be installed to ensure that there are no coincident joints.Inner face plasterboard linings (Internal)Gyproc Infill Stud Glasroc X (External)GSF1 Flat StrapHorizontal Board JointGYPROC FACADE SYSTEM | 5
SYSTEMS120mins Fire Resistance
Gyproc Facade SystemT106015 (EN)A non-loadbearing external wall construction including a 20mm deflection head with an inner layer of Glasroc X Sheathing Board 12.5mm and outer layer of 200mm Isover Polterm Max Plus Insulation to external side and two layers of Gyproc SoundBloc 15mm to the internal side of 100mm Gypframe metal stud framework. 100mm Isover Acoustic Insulation in the cavity. For heights up to 3000mm.Fire Insulation 120 Fire Integrity (mins) 120 Maximum Height (mm) 3000List of productsExternal insulation Layer 1: 200mm Isover Polterm Max PlusBoard side 2 Layer 1: Glasroc X Sheathing Board 12.5mmStud 100mm Gyproc Facade StudHead channel 104mm Gyproc Facade Slotted Head TrackBase channel 104mm Gyproc Facade Base TrackStud fixing Gyproc Wafer Head Jack-Point Screws 13mmAbutments and openings 100mm Gyproc Facade StudInsulation Layer 1: 100mm Isover Acoustic InsulationBoard side 1 Layer 1: Gyproc SoundBloc 15mmLayer 2: Gyproc SoundBloc 15mmScrews side 1 Layer 1: Gyproc Jack-Point Screws 25mmLayer 2: Gyproc Jack-Point Screws 41mmScrews side 2 Layer 1: Glasroc X Screws 25mmExternal board joints Glasroc X SealantSealant Gyproc SealantFixing strap Gypframe GFS1 Fixing StrapGYPROC FACADE SYSTEM | 7
Gyproc Facade SystemT106022 (EN)A non-loadbearing external wall construction including a 20mm deflection head with an inner layer of Glasroc X Sheathing Board 12.5mm to external side and three layers of Gyproc FireLine 15mm to the internal side of 100mm Gypframe metal stud framework. 50mm Isover Acoustic Insulation in the cavity. For heights up to 4000mmFire Insulation120Fire Integrity (mins)120Maximum Height (mm)4000Sound Insulation (Airbourne) Rw (dB)50List of productsBoard side 2 Layer 1: Glasroc X Sheathing Board 12.5mmStud 100mm Gyproc Facade StudAbutments and openings 100mm Gyproc Facade StudHead channel 104mm Gyproc Facade Slotted Head TrackBase channel 104mm Gyproc Facade Base TrackStud fixing Gyproc Wafer Head Jack-Point Screws 13mmInsulation Layer 1: 50mm Isover Acoustic InsulationBoard side 1 Layer 1: Gyproc FireLine 15mmLayer 2: Gyproc FireLine 15mmLayer 3: Gyproc FireLine 15mmScrews side 1 Layer 1: Gyproc Jack-Point Screws 25mmLayer 2: Gyproc Jack-Point Screws 41mmLayer 3: Gyproc Jack-Point Screws 60mmScrews side 2 Layer 1: Glasroc X Screws 25mmExternal board joints Glasroc X SealantSealant Gyproc SealantFixing strap Gypframe GFS1 Fixing Strap8 | GYPROC FACADE SYSTEM
Gyproc Facade SystemT106023 (EN)A non-loadbearing external wall construction including a 20mm deflection head with an inner layer of Glasroc X Sheathing Board 12.5mm and outer layer of 100mm Isover Polterm Max Plus Insulation to external side and three layers of Gyproc FireLine 15mm to the internal side of 100mm Gyproc Facade Stud framework. 50mm Isover Acoustic Insulation in the cavity. For heights up to 4000mm.Fire Insulation120Fire Integrity (mins)120Maximum Height (mm)4000Sound Insulation (Airbourne) Rw (dB)50List of productsExternal insulation Layer 1: 100mm Isover Polterm Max PlusBoard side 2 Layer 1: Glasroc X Sheathing Board 12.5mmStud 100mm Gyproc Facade StudAbutments and openings 100mm Gyproc Facade StudBase channel 104mm Gyproc Facade Base TrackHead channel 104mm Gyproc Facade Slotted Head TrackStud fixing Gyproc Wafer Head Jack-Point Screws 13mmInsulation Layer 1: 50mm Isover Acoustic InsulationBoard side 1 Layer 1: Gyproc FireLine 15mmLayer 2: Gyproc FireLine 15mmLayer 3: Gyproc FireLine 15mmScrews side 1 Layer 1: Gyproc Jack-Point Screws 25mmLayer 2: Gyproc Jack-Point Screws 41mmLayer 3: Gyproc Jack-Point Screws 60mmScrews side 2 Layer 1: Glasroc X Screws 25mmSealant Gyproc SealantExternal board joints Glasroc X SealantFixing strap Gypframe GFS1 Fixing StrapGYPROC FACADE SYSTEM | 9
Gyproc Facade SystemT106030 (EN)A non-loadbearing external wall construction including a 20mm deflection head with one layer of Glasroc X Sheathing Board 12.5mm to external side and three layers of Gyproc FireLine 15mm to the internal side of 100mm Gyproc Facade Stud framework. 100mm Isover Steel Frame Infill Batt in the cavity. For heights up to 4000mm.Fire Insulation 120 Fire Integrity (mins) 120 Maximum Height (mm) 4000List of productsBoard side 2 Layer 1: Glasroc X Sheathing Board 12.5mmStud 100mm Gyproc Facade StudBase channel 104mm Gyproc Facade Base TrackHead channel 104mm Gyproc Facade Slotted Head TrackAbutments and openings 100mm Gyproc Facade StudStud fixing Gyproc Wafer Head Jack-Point Screws 13mmInsulation Layer 1: 100mm Isover Steel Frame Infill BattBoard side 1 Layer 1: Gyproc FireLine 15mmLayer 2: Gyproc FireLine 15mmLayer 3: Gyproc FireLine 15mmScrews side 1 Layer 1: Gyproc Jack-Point Screws 25mmLayer 2: Gyproc Jack-Point Screws 41mmLayer 3: Gyproc Jack-Point Screws 60mmScrews side 2 Layer 1: Glasroc X Screws 25mmExternal board joints Glasroc X SealantSealant Gyproc SealantFixing strap Gypframe GFS1 Fixing Strap10 | GYPROC FACADE SYSTEM
Gyproc Facade SystemT106036 (EN)A non-loadbearing external wall construction including a 20mm deflection head with an inner layer of Glasroc X Sheathing Board 12.5mm and an outer of 200mm Isover Polterm Max Plus Insulation to the external side with an inner layer of Gyproc Habito 12.5mm and two outer layers of Gyproc SoundBloc 15mm to the internal side of 100mm Gyproc Facade Stud framework. 100mm Isover Acoustic Insulation in the cavity. For heights up to 3000mm.Fire Insulation 120 Fire Integrity (mins) 120 Maximum Height (mm) 3000List of productsExternal insulation Layer 1: 200mm Isover Polterm Max PlusBoard side 2 Layer 1: Glasroc X Sheathing Board 12.5mmStud 100mm Gyproc Facade StudHead channel 104mm Gyproc Facade Slotted Head TrackBase channel 104mm Gyproc Facade Base TrackAbutments and openings 100mm Gyproc Facade StudStud fixing Gyproc Wafer Head Jack-Point Screws 13mmInsulation Layer 1: 100mm Isover Acoustic InsulationBoard side 1 Layer 1: Gyproc Habito 12.5mmLayer 2: Gyproc SoundBloc 15mmLayer 3: Gyproc SoundBloc 15mmScrews side 2 Layer 1: Glasroc X Screws 25mmScrews side 1 Layer 1: Gyproc Jack-Point Screws 25mmLayer 2: Gyproc Jack-Point Screws 41mmLayer 3: Gyproc Jack-Point Screws 60mmExternal board joints Glasroc X SealantSealant Gyproc SealantFixing strap Gypframe GFS1 Fixing StrapGYPROC FACADE SYSTEM | 11
SYSTEMS90mins Fire Resistance
Gyproc Facade SystemT106021 (EN)A non-loadbearing external wall construction including a 20mm deflection head with an inner layer of Glasroc X Sheathing Board 12.5mm and outer layer of 100mm Isover Polterm Max Plus Insulation to external side and two layers of Gyproc SoundBloc 15mm to the internal side of 100mm Gyproc Facade Stud framework. 50mm Isover Acoustic Insulation in the cavity. For heights up to 4000mm.Fire Insulation90Fire Integrity (mins)90Maximum Height (mm)4000Sound Insulation (Airbourne) Rw (dB)56List of productsExternal insulation Layer 1: 100mm Isover Polterm Max PlusBoard side 2 Layer 1: Glasroc X Sheathing Board 12.5mmBase channel 104mm Gyproc Facade Base TrackHead channel 104mm Gyproc Facade Slotted Head TrackStud 100mm Gyproc Facade StudAbutments and openings 100mm Gyproc Facade StudStud fixing Gyproc Jack-Point Screws 13mmInsulation Layer 1: 50mm Isover Acoustic InsulationBoard side 1 Layer 1: Gyproc SoundBloc 15mmLayer 2: Gyproc SoundBloc 15mmScrews side 1 Layer 1: Gyproc Jack-Point Screws 25mmLayer 2: Gyproc Jack-Point Screws 41mmScrews side 2 Layer 1: Glasroc X Screws 25mmExternal board joints Glasroc X SealantSealant Gyproc SealantFixing strap Gypframe GFS1 Fixing StrapGYPROC FACADE SYSTEM | 13
Gyproc Facade SystemT106033 (EN)A non-loadbearing external wall construction including a 20mm deflection head with one layer of Glasroc X Sheathing Board 12.5mm to external side an inner layer of Gyproc Habito 12.5mm and two outer layers of Gyproc SoundBloc 15mm to the internal side of 100mm Gypframe metal stud framework. 50mm Isover Acoustic Insulation in the cavity. For heights up to 3000mm.Fire Insulation90Fire Integrity (mins)90Maximum Height (mm)3000Sound Insulation (Airbourne) Rw (dB)51List of productsBoard side 2 Layer 1: Glasroc X Sheathing Board 12.5mmStud 100mm Gyproc Facade StudHead channel 104mm Gyproc Facade Slotted Head TrackBase channel 104mm Gyproc Facade Base TrackAbutments and openings 100mm Gyproc Facade StudStud fixing Gyproc Wafer Head Jack-Point Screws 13mmInsulation Layer 1: 50mm Isover Acoustic InsulationBoard side 1 Layer 1: Gyproc Habito 12.5mmLayer 2: Gyproc SoundBloc 15mmLayer 3: Gyproc SoundBloc 15mmScrews side 1 Layer 1: Gyproc Jack-Point Screws 25mmLayer 2: Gyproc Jack-Point Screws 41mmLayer 3: Gyproc Jack-Point Screws 60mmScrews side 2 Layer 1: Glasroc X Screws 25mmExternal board joints Glasroc X SealantSealant Gyproc SealantFixing strap Gypframe GFS1 Fixing Strap14 | GYPROC FACADE SYSTEM
Gyproc Facade SystemT106034 (EN)A non-loadbearing external wall construction including a 20mm deflection head with an inner layer of Glasroc X Sheathing Board 12.5mm and outer layer of 50mm Isover Polterm Max Plus Insulation to external side an inner layer of Gyproc Habito 12.5mm and two outer layers Gyproc SoundBloc 15mm to the internal side of 100mm Gyproc Facade Stud framework. 50mm Isover Acoustic Insulation in the cavity. For heights up to 4000mm.Fire Insulation90Fire Integrity (mins)90Maximum Height (mm)4000Sound Insulation (Airbourne) Rw (dB)54List of productsExternal insulation Layer 1: 50mm Isover Polterm Max PlusBoard side 2 Layer 1: Glasroc X Sheathing Board 12.5mmStud 100mm Gyproc Facade StudAbutments and openings 100mm Gyproc Facade StudHead channel 104mm Gyproc Facade Slotted Head TrackBase channel 104mm Gyproc Facade Base TrackStud fixing Gyproc Wafer Head Jack-Point Screws 13mmInsulation Layer 1: 50mm Isover Acoustic InsulationBoard side 1 Layer 1: Gyproc Habito 12.5mmLayer 2: Gyproc SoundBloc 15mmLayer 3: Gyproc SoundBloc 15mmScrews side 1 Layer 1: Gyproc Jack-Point Screws 25mmLayer 2: Gyproc Jack-Point Screws 41mmLayer 3: Gyproc Jack-Point Screws 60mmScrews side 2 Layer 1: Glasroc X Screws 25mmExternal board joints Glasroc X SealantSealant Gyproc SealantFixing strap Gypframe GFS1 Fixing StrapGYPROC FACADE SYSTEM | 15
Gyproc Facade SystemT106035 (EN)A non-loadbearing external wall construction including a 20mm deflection head with an inner layer of Glasroc X Sheathing Board 12.5mm and outer layer of 100mm Isover Polterm Max Plus Insulation to external side an inner layer of Gyproc Habito 12.5mm and two outer layers of Gyproc SoundBloc 15mm to the internal side of 100mm Gypframe metal stud framework. 50mm Isover Acoustic Insulation in the cavity. For heights up to 3000mm.Fire Insulation90Fire Integrity (mins)90Maximum Height (mm)4000Sound Insulation (Airbourne) Rw (dB)56List of productsExternal insulation Layer 1: 100mm Isover Polterm Max PlusBoard side 2 Layer 1: Glasroc X Sheathing Board 12.5mmStud 100mm Gyproc Facade StudHead channel 104mm Gyproc Facade Slotted Head TrackBase channel 104mm Gyproc Facade Base TrackAbutments and openings 100mm Gyproc Facade StudStud fixing Gyproc Head Jack-Point Screws 13mmInsulation Layer 1: 50mm Isover Acoustic InsulationBoard side 1 Layer 1: Gyproc Habito 12.5mmLayer 2: Gyproc SoundBloc 15mmLayer 3: Gyproc SoundBloc 15mmScrews side 1 Layer 1: Gyproc Jack-Point Screws 25mmLayer 2: Gyproc Jack-Point Screws 41mmLayer 3: Gyproc Jack-Point Screws 60mmScrews side 2 Layer 1: Glasroc X Screws 25mmExternal board joints Glasroc X SealantSealant Gyproc SealantFixing strap Gypframe GFS1 Fixing Strap16 | GYPROC FACADE SYSTEM
MEET THENEW PLAYER IN EXTERIORINSULATIONwww.isover.ieMOVE BY MOVE, WE’RE HERETHERMAL 0.035 W/mKNON-COMBUSTIBLE Euroclass A1 making it suitable for projects above and below 18m in heightWATER REPELLENT Moisture Ingress ProtectionNON-COMBUSTIBLE External Noise ReductionNon-combustible stone wool insulation sheathed in a black glass veil for high performance anda classy finish.PERFECT FOR VENTILATED RAINSCREEN CLADDING AND OVERCLADDING SYSTEMSDesigned to integrate with ISOVER intelligent membranes and internal insulationPOLTERMMAX PLUSSCAN FOR MORE INFORMATION
SYSTEMS60mins Fire Resistance
Gyproc Facade SystemT106019 (EN)A non-loadbearing external wall construction including a 20mm deflection head with one layer of Glasroc X Sheathing Board 12.5mm to external side and two layers of Gyproc SoundBloc 15mm to the internal side of 100mm Gyproc Facade Stud framework. 50mm Isover Acoustic Insulation in the cavity. For heights up to 3000mm.Fire Insulation60Fire Integrity (mins)60Maximum Height (mm)3000Sound Insulation (Airbourne) Rw (dB)51List of productsBoard side 2 Layer 1: Glasroc X Sheathing Board 12.5mmStud 100mm Gyproc Facade StudBase channel 104mm Gyproc Facade Base TrackHead channel 104mm Gyproc Facade Slotted Head TrackAbutments and openings 100mm Gyproc Facade StudStud fixing Gyproc Wafer Head Jack-Point Screws 13mmBoard side 1 Layer 1: Gyproc SoundBloc 15mmLayer 2: Gyproc SoundBloc 15mmScrews side 1 Layer 1: Gyproc Jack-Point Screws 25mmLayer 2: Gyproc Screws 41mmScrews side 2 Layer 1: Glasroc X Screws 25mmInsulation Layer 1: 50mm Isover Acoustic Insulation Sealant Gyproc SealantExternal board joints Glasroc X SealantFixing strap Gypframe GFS1 Fixing StrapGYPROC FACADE SYSTEM | 19
Gyproc Facade SystemT106017 (EN)A non-loadbearing external wall construction, including a 20mm deflection head, with an inner layer of Glasroc X Sheathing Board 12.5mm and outer layer of 50mm Isover Polterm Max Plus Insulation to external side and one layer of Gyproc FireLine 15mm to the internal side of 100mm Gypframe infill stud framework. 50mm Isover Acoustic Insulation in the cavity. For heights up to 4000mm.Fire Insulation60Fire Integrity (mins)60Maximum Height (mm)4000Sound Insulation (Airbourne) Rw (dB)47List of productsExternal insulation Layer 1: 50mm Isover Polterm Max PlusBoard side 2 Layer 1: Glasroc X Sheathing Board 12.5mmStud 100mm Gyproc Facade StudBase channel 104mm Gyproc Facade Base TrackHead channel 104mm Gyproc Facade Slotted Head TrackAbutments and openings 100mm Gyproc Facade StudStud fixing Gyproc Wafer Head Jack-Point Screws 13mmInsulation Layer 1: 50mm Isover Acoustic InsulationBoard side 1 Layer 1: Gyproc FireLine 15mmScrews side 2 Layer 1: Glasroc X Screws 25mmScrews side 1 Layer 1: Gyproc Jack-Point Screws 25mmExternal board joints Glasroc X SealantSealant Gyproc SealantFixing strap Gypframe GFS1 Fixing Strap20 | GYPROC FACADE SYSTEM
Gyproc Facade SystemT106018 (EN)A non-loadbearing external wall construction, including a 20mm deflection head, with an inner layer of Glasroc X Sheathing Board 12.5mm and outer layer of 100mm Isover Polterm Max Plus Insulation to external side and one layer of Gyproc FireLine 15mm to the internal side of 100mm Gypframe infill stud framework. 50mm Isover Acoustic Insulation in the cavity. For heights up to 4000mm.Fire Insulation60Fire Integrity (mins)60Maximum Height (mm)4000Sound Insulation (Airbourne) Rw (dB)52List of productsExternal insulation Layer 1: 100mm Isover Polterm Max PlusBoard side 2 Layer 1: Glasroc X Sheathing Board 12.5mmStud 100mm Gyproc StudBase channel 104mm Gyproc Facade Base TrackHead channel 104mm Gyproc Facade Slotted Head TrackAbutments and openings 100mm Gyproc StudStud fixing Gyproc Wafer Head Jack-Point Screws 13mmInsulation Layer 1: 50mm Isover Acoustic InsulationBoard side 1 Layer 1: Gyproc FireLine 15mmScrews side 1 Layer 1: Gyproc Jack-Point Screws 25mmScrews side 2 Layer 1: Glasroc X Screws 25mmExternal board joints Glasroc X SealantSealant Gyproc SealantFixing strap Gypframe GFS1 Fixing StrapGYPROC FACADE SYSTEM | 21
Gyproc Facade SystemT106031 (EN)A non-loadbearing external wall construction including a 20mm deflection head with an inner layer of Glasroc X Sheathing Board 12.5mm and outer layer of 50mm Isover Polterm Max Plus Insulation to external side an inner layer of Gyproc Habito 12.5mm and outer layer Gyproc FireLine 15mm to the internal side of 100mm Gypframe infill stud framework. 50mm Isover Acoustic Insulation in the cavity. For heights up to 4000mm.Fire Insulation60Fire Integrity (mins)60Maximum Height (mm)4000Sound Insulation (Airbourne) Rw (dB)47List of productsExternal insulation Layer 1: 50mm Isover Polterm Max PlusBoard side 2 Layer 1: Glasroc X Sheathing Board 12.5mmStud 100mm Gyproc Facade StudAbutments and openings 100mm Gyproc Facade StudHead channel 104mm Gyproc Facade Slotted Head TrackBase channel 104mm Gyproc Facade Base TrackStud fixing Gyproc Wafer Head Jack-Point Screws 13mmInsulation Layer 1: 50mm Isover Acoustic InsulationBoard side 1 Layer 1: Gyproc Habito 12.5mmLayer 2: Gyproc FireLine 15mmScrews side 1 Layer 1: Gyproc Jack-Point Screws 25mmLayer 2: Gyproc Jack-Point Screws 41mmScrews side 2 Layer 1: Glasroc X Screws 25mmSealant Gyproc SealantExternal board joints Glasroc X SealantFixing strap Gypframe GFS1 Fixing Strap22 | GYPROC FACADE SYSTEM
Gyproc Facade SystemT106032 (EN)A non-loadbearing external wall construction including a 20mm deflection head with an inner layer of Glasroc X Sheathing Board 12.5mm and outer layer of 100mm Isover Polterm Max Plus Insulation to external side an inner layer of Gyproc Habito 12.5mm and outer layer Gyproc FireLine 15mm to the internal side of 100mm Gypframe infill stud framework. 50mm Isover Acoustic Insulation. For heights up to 4000mm.Fire Insulation60Fire Integrity (mins)60Maximum Height (mm)4000Sound Insulation (Airbourne) Rw (dB)52List of productsExternal insulation Layer 1: 100mm Isover Polterm Max PlusBoard side 2 Layer 1: Glasroc X Sheathing Board 12.5mmStud 100mm Gyproc Facade StudHead channel 104mm Gyproc Facade Slotted Head TrackBase channel 104mm Gypframe ChannelAbutments and openings 100mm Gyproc Facade StudStud fixing Gyproc Wafer Head Jack-Point Screws 13mmInsulation Layer 1: 50mm Isover Acoustic InsulationBoard side 1 Layer 1: Gyproc Habito 12.5mmLayer 2: Gyproc FireLine 15mmScrews side 1 Layer 1: Gyproc Jack-Point Screws 25mmLayer 2: Gyproc Jack-Point Screws 41mmScrews side 2 Layer 1: Glasroc X Screws 25mmExternal board joints Glasroc X SealantSealant Gyproc SealantFixing strap Gypframe GFS1 Fixing StrapGYPROC FACADE SYSTEM | 23
Gyproc Sealant for optimum sound insulationGyproc Facade System Construction detailsThe following pages highlight key examples of available construction details. Further details are available to support your project and optimise performance.1. Typical deflection detail – tested for up to 120 mins (inside-to-out)Indicative concrete slabGypframe slotted head track suitably fixed to 'Z' bars in accordance with manufacturer's instructionsGypframe infill stud installed in accordance with manufacturer's instructionsGypframe MF6 Perimeter Channel suitably fixed to sot at max. 600mm centres50mm Isover Acoustic InsulationGypframe GFS1 Fixing Strap to receive uppermost board fixings (no fixings into head channel)20mm joint sealed with 60mm wide Illbruck ME010 breather membrane tape secured with 2 beads of Illbruck SP025 adhesive (top and bottom)Gypframe GA4 Steel Angle fixed through plasterboard to angle with Gyproc Drywall ScrewIndicative external cladding with appropriate cavity barriers where requiredGypframe GA4 Steel Angle suitably fixed to 'Z' bars with Gyproc Wafer Head Drywall Screw Indicative intumescent painted beamCavity barrier (indicative) where required. Defined and specified by othersGypframe GA2 Steel Angle pre-fixed to MF6 Perimeter Channel with Gyproc Wafer Head Drywall Screw at max. 600mm centresGypframe GA4 Steel Angle fixed to steel beam at max. 600mm centresIndicative stone wool insulation by others (45kg/m3)Indicative 'Z' bars sized and supplied by others at 300mm centres and suitably fixed to beam24 | GYPROC FACADE SYSTEM
We can provide details to fully encase all structural steel. It may be possible through third party assessment of test data (by a suitably qualified structural or fire engineer) to determine whether the conditions oered by the lining are sucient to protect hot rolled elements, without the need for additional fire protection measures.One layer Glasroc X Sheathing Board 12.5mm fixed with 25mm Glasroc X Screws (max. 2mm metal thickness) at 300mm centres. Continuous 6mm bead of Glasroc X Sealant at board joints. Vertical joints backed with Gypframe GFS1 Fixing StrapIsover Polterm Max Plus (thickness to specification) suitably fixedOne layer Glasroc X Sheathing Board 12.5mm fixed with 25mm Glasroc X Screws to Gypframe infill stud. Continuous 6mm bead of Glasroc X Sealant at board jointsLadder frame of Gypframe MF5 Ceiling Sections at 450mm centres capped at ends with Gypframe MF6 perimeter channel, all fixed together with Gyproc Wafer Head Drywall Screws and to GA4 angle with Gyproc Wafer HeadGypframe MF6 Perimeter ChannelThree layers Gyproc FireLine 15mm fixed with 25mm, 41mm and 60mm Gyproc Jack-Point Screws to Gypframe infill stud studs at 300mm centres (up to 2mm metal thickness)Three layers Gyproc FireLine 15mm fixed with 25mm, 41mm and 60mm Gyproc Jack-Point Screws to Gypframe infill stud studs at 300mm centres (up to 2mm metal thickness)Fire resistance120 mins Details for 60 and 90 minute fire resistance availableGYPROC FACADE SYSTEM | 25
Scale = x .14Gypframe infill studs at specified centresIsover insulation to meet thermal requirementsIsover insulation to meet acoustic requirementsGyproc Facade System Construction detailsGlasroc X SealantIndicative external finishCavity barrier (indicative) where required defined and specified by othersGypframe ‘C’ Studs where requiredOne layer Glasroc X Sheathing Board 12.5mm fixed with 25mm Glasroc X Screws (max. 2mm metal thickness) at 300mm centres. Continuous 6mm bead of Glasroc X Sealant at board joints2. Junction with external wall Isover Polterm Max Plus (thickness to specification) suitably fixedOne layer Gyproc plasterboard or Glasroc specialist board fixed with suitable Gyproc screws at 300mm centres (200mm centres at external angles)One layer Gyproc FireLine 15mm fixed with 25mm Gyproc Jack-Point screws (max. 2mm metal thickness) at 300mm centresGypframe 'C' stud fixed through board to Gypframe infill stud with suitable screws (Gyproc Jack-Point screws max. 2mm metal thickness) at 600mm centres (in two lines staggered by 300mm for 92mm and 146mm studs)Additional Gypframe infill stud at junctionWe can provide details to fully encase all structural steel. It may be possible through third party assessment of test data (by a suitably qualified structural or fire engineer) to determine whether the conditions oered by the lining are sucient to protect hot rolled elements, without the need for additional fire protection measures.Fire resistance60 mins Details for 30 and 60 minute fire resistance available26 | GYPROC FACADE SYSTEM
Scale = x .14Gypframe infill studs at specified centresIsover insulation to meet thermal requirementsIsover insulation to meet requirementsGlasroc X SealantIndicative external finishCavity barrier (indicative) where required. Defined and specified by othersOne layer Glasroc X Sheathing Board 12.5mm fixed with 25mm Glasroc X Screws (max. 2mm metal thickness) at 300mm centres. Continuous 6mm bead of Glasroc X Sealant at board jointsIsover Polterm Max Plus (thickness to specification) suitably fixedTwo layers Gyproc plasterboard or Glasroc specialist board fixed with suitable Gyproc screws at 300mm centres (200mm centres at external angles)Two layers Gyproc SoundBloc 15mm fixed with 25mm and 41mm Gyproc Jack-Point screws at 300mm centresAdditional Gypframe 'C' stud at junctionTwo lines of Gypframe ‘I’ Studs at specified centresGypframe 'C' stud fixed through board to stud with suitable Gyproc screws at 600mm centresStone mineral wool 100kg/m3 minimum density by othersWe can provide details to fully encase all structural steel. It may be possible through third party assessment of test data (by a suitably qualified structural or fire engineer) to determine whether the conditions oered by the lining are sucient to protect hot rolled elements, without the need for additional fire protection measures.3. GypWall Twin Frame Independent junction with Gypframe infill external wallFire resistance90 mins Details for 60 and 90 minute fire resistance availableGYPROC FACADE SYSTEM | 27
Gyproc Facade System Construction detailsWe can provide details to fully encase all structural steel. It may be possible through third party assessment of test data (by a suitably qualified structural or fire engineer) to determine whether the conditions oered by the lining are sucient to protect hot rolled elements, without the need for additional fire protection measures.4. Window revealScale = x .14One or two layers Gyproc plasterboard or Glasroc specialist board fixed with Gyproc Jack-Point screws (max. 2mm metal thickness) at 300mm centres (200mm centres at external angles)Indicative window cillIsover insulation to meet thermal requirementsGyproc Sealant for optimum sound insulationGypframe infill studs at specified centres installed in accordance with manufacturer’s instructionsOne layer Glasroc X Sheathing Board 12.5mm fixed with 25mm Glasroc X Screws (max. 2mm metal thickness) at 300mm centres. Continuous 6mm bead of Glasroc X Sealant at board jointsIsover Polterm Max Plus suitably fixed through board to Gypframe infill studIndicative external finishCavity barrier where required.Indicative window frame independently supported by the Gypframe infill stud framework28 | GYPROC FACADE SYSTEM
Scale = x .145. Window head and cillWe can provide details to fully encase all structural steel. It may be possible through third party assessment of test data (by a suitably qualified structural or fire engineer) to determine whether the conditions oered by the lining are sucient to protect hot rolled elements, without the need for additional fire protection measures.One or two layers Gyproc plasterboard or Glasroc specialist board fixed with Gyproc Jack-Point screws (max. 2mm metal thickness) at 300mm centres (200mm centres at external angles)One or two layers Gyproc plasterboard or Glasroc specialist board fixed with Gyproc Jack-Point screws (max. 2mm metal thickness) at 300mm centres (200mm centres at external angles)Isover insulation to meet thermal requirementsGypframe infill channel installed in accordance with manufacturer’s instructionsGypframe infill studs at specified centres installed in accordance with manufacturer’s instructionsOne layer Glasroc X Sheathing Board 12.5mm fixed with 25mm Glasroc X Screws (max. 2mm metal thickness) at 300mm centres. Continuous 6mm bead of Glasroc X Sealant at board jointsIsover Polterm Max Plus suitably fixed through board to Gypframe infill studIndicative external finishGyproc Sealant for sound insulationCavity barrier where requiredIndicative window frame independently supported by the Gypframe infill stud frameworkIndicative window cill GYPROC FACADE SYSTEM | 29
Looking for a bespoke solution?Did you know that we oer the creation of bespoke length Gyproc plasterboard and Gypframe metal products? Whether you require a non-standard length for Gypframe metal or alternative edge profile, vapour check or other specification changes for Gyproc plasterboards, we’ll endeavour to provide you with the best possible solution, subject to manufacturing constraints.30 | GYPROC FACADE SYSTEM
Benefits of bespoke productsBy using Gyproc bespoke length products, significant reductions in on-site cutting means:LOWERInstallation timesLOWERCostsLOWERProject CO2 emissions/vehicle miles¤LOWERInstallation timesLOWERCostsLOWERProject CO2 emissions/vehicle milesLOWERInstallation timesLOWERCostsLOWERProject CO2 emissions/vehicle milesTalk to us about your projectYou can discuss your project requirements for non-standard lengths of Gyproc plasterboard or Gypframe metal products with either your local Gyproc Area Sales Manager, or with our Technical Team on Free Phone ROI 1800 744480 / NI 0845 3990159.Terms and Conditions ApplyPlease note that special Terms and Conditions apply for bespoke product orders regarding the placing of orders, lead times and delivery:• Minimum order quantities apply.• All bespoke product orders require a written irrevocable order.• Lead time applies from when product availability is confirmed by Customer Service.• Subject to manufacturing constraints.• All bespoke products not delivered within 30 days of manufacture will be invoiced in full.PlasterboardsAny plasterboard product from our entire range is available as a bespoke order with the exception of the following: Plank, CoreBoard, Ceiling Products, Glasroc F MULTIBOARD, Glasroc F FIRECASE, Glasroc H TILEBACKER, Rigidur, Habito®, Glasroc X and Aquaroc.Lead Time: 15 working days Minimum Order: 1000 sheetsMetalLead times:Dependent on component for consistencyup to 10 days: up to 15 days:48 S 50 ‘C’ Stud 70 S 50 ‘C’ Stud60 I 50 ‘I’ Stud 60 I 70 ‘I’ Stud 70 I 70 ‘I’ StudMinimum Length: 2400mm (excludes MF5) Maximum Length: 8000mm (dependent on component)Minimum Order: 1000LM (e.g. 2500mm x 400 lengths)For all other components, due to case by case variables, lead times will be established at time of order.If your customers are planning a project which could benefit from reduced plasterboard/metal waste, labour costs and vehicle movements, we can provide assistance at each stage of the process, get in touch now.Contact your local Gyproc Area Sales Manager or our Technical Team on Free Phone: ROI 1800 744480 NI 0845 3990159GYPROC FACADE SYSTEM | 31
Skip CollectedRecycling Facility100% RecycledPlasterboard O-Cuts TraceabilityCertificateSkip Supplied Manufacturing locally, in Ireland, with over 80 years’ experience in plaster, plasterboard and ceiling solutions, we have a multitude of high performance products and systems. You’ll find our plaster, plasterboard, metal and ceiling solutions in almost every kind of building in the country. Our mission is to develop innovative products and services that help customers build better spaces to live work and play, making the world a better home. We base our approach to business on the following; changing how we build, for the better, for the future; caring for the environment we operate within; supporting and developing our people; connecting with our communities and supporting their economic development.In every kind of building – from home to work, from the local supermarket to the local hospital – we help create partitions, provide comfort, protect against fire and insulate against sound.We are continually working to help our customers, suppliers and partners in the supply chain support more sustainable construction while we focus on developing more sustainable products, systems and services to add to our sustainability oering. We recognise the social and environmental impacts of transportation, and the need to adopt appropriate strategies to reduce adverse impacts by actively assessing all viable methods of transport in and out of the business, for both product and people. BES 6001In addition to use in BREEAM, BES 6001 responsible sourcing certification has now been validated as a credit for use in LEED projects. BES 6001 ‘Excellent’ has been achieved for our locally manufactured Gyproc plasters and plasterboard as well as Gypframe Metal, Glasroc F plasterboards and ISOVER insulation.Volatile Organic CompoundsAll locally manufactured Gyproc plasters and plasterboards have been assessed by Normec testing and demonstrates compliance with VOC requirements on low emitting products of French A+ class, German AgBB/ABG, BREEAM Int (exemplary level) and LEED EU. Testing was performed according to the latest versions of EN 16516 and ISO 16000 series by ISO/IEC 17025 accredited test laboratory Servaco/Normec Product Testing.Waste management and resource use Our approach has been to adopt the waste hierarchy, and only use landfill as a last resort. Ensuring sustainable purchasing and minimising use of raw materials is an important part of our strategy. Dependence on virgin raw materials continues to be minimised through the use of reclaimed and recycled materials, and using resources in the most ecient manner. We have lead the industry in recycling plasterboard waste, reducing the pressure on landfill and preserving gypsum deposits. This has brought us to where we are today with the inclusion of up to 15% recycled content in our plasterboard manufacture process.Sustainability32 | GYPROC FACADE SYSTEM
Skip CollectedRecycling Facility100% RecycledPlasterboard O-Cuts TraceabilityCertificateSkip Supplied Nationwide Gyproc Plasterboard Recycling ServiceAllied Recycling Unit 74, Naas Industrial Estate, Naas, Co. Kildare.Phone: 01 278 7080 Email: naas@alliedrecycling.ieOr through their national sales manager:Kieran Kelly Sales ManagerMobile: 086 380 8602 Email: kieran.kelly@alliedrecycling.ieor to open an account with Allied Recycling please contact them at:Responsible waste management is a priority for us and we’ve always believed that eective waste management makes good environmental and business sense.Gyproc along with our partner, Allied Recycling, has developed a cost-eective process to take back and recycle Gyproc plasterboard o-cuts. Allied Recycling will provide you with a traceability certificate which will be endorsed by Gyproc to prove that your plasterboard ocuts were 100% recycled back into the process – keeping you compliant with Irish law. By managing your waste, we ensure you’re adhering to EU Landfill Directive as dictated by Irish Law.GYPROC FACADE SYSTEM | 33
We want to make the selection of sustainable solutions simpler for our customers. In order to do this, we have begun developing Life Cycle Assessments (LCA) for our product ranges.Since December 2013 we have published eleven Environmental Product Declarations (EPDs) across two brands, Gyproc and Isover. The independently verified EPDs, which are the result of the Life Cycle Assessment (LCA) process, are designed to give users information on the environmental performance of our products across numerous impact categories.The underlying LCA considers the entire life cycle of a product solution from cradle-to-grave. As part of the assessment, a comprehensive range of factors are considered, including the potential environmental eects of raw materials, the manufacturing process, logistics, installation, performance in use and finally the product at the end of its life. EPDs include information on raw material use, energy use and eciency, content of materials and chemical substances, emissions to air, soil and water and waste generation – this enables our customers to understand the full environmental impacts of the product ranges being selected.The EPD results also enable us to understand at which stage our products have the greatest impact on the environment. We can therefore make better informed decisions on processes involved in the production of current and new products, as well as taking steps to minimise the environmental impact of our products across their lifecycle. EPDs also provide clear evidence for environmental building certification schemes, meeting credit requirements in BREEAM, for example.Environmental Product DeclarationsTo quickly download any of our EPD’s visit gyproc.ie or isover.ie34 | GYPROC FACADE SYSTEM
What is BREEAM®?BREEAM® (Building Research Establishment’s Environmental Assessment Method) is an environmental assessment method for buildings, created in the UK in 1990. It is the most important certification worldwide, regarding the number of certified buildings, with 200,000 buildings certified and over a million registered. BREEAM® has dierent schemes of certification, depending on the country, the building type (oce building, retail etc.) and the construction type (new, refurbishment etc.).ReferenceBREEAM® International New Construction 2013 > This is the rating system that has been used as a reference in this documentBREEAM® 2011 for new construction of non-domestic buildings BREEAM® UK CommunitiesBREEAM® UK In-UseBREEAM® UK RefurbishmentEcoHomes (UK)BREEAM® Europe CommercialBREEAM® International BespokeBREEAM® RatingCredits are awarded in 10 categories according to the performance of the building assessed. These credits are then added together to produce a single overall score.Management 12%Health & Wellbeing 15%Energy 19%Transport 8%Water 6%Materials 12.5%Waste 7.5%Landuse and Ecology 10%Pollution 10%Innovation 10% bonusManagement 12%Health & Wellbeing 15%Energy 19%Transport 8%Water 6%Materials 12.5%Waste 7.5%Landuse and Ecology 10%Pollution 10%Innovation 10% bonusTo find out more about Gyproc and BREEAM visit gyproc.ieThe BREEAM® CertificationGYPROC FACADE SYSTEM | 35
What is LEED®?LEED®, or Leadership in Energy & Environmental Design, is a green building certification programme that recognises best-in-class building strategies and practices.LEED® provides rating systems that are voluntary, consensus-based, market-driven, and based on accepted energy and environmental principles. The LEED® rating systems were developed by US Green Building Council committees in 1998. In January 2015, there were more than 76,500 registered projects and 35,000 certified buildings1.To receive LEED® certification, building projects must satisfy prerequisites and earn points to achieve dierent levels of certification. Prerequisites and credits dier for each rating system, depending on the type of building (oce, school, home, etc.) and the type of project (new or renovation). In total, there are five rating systems that address multiple project types.The certification is developed by the US Green Building Council. As a platinum member of this organisation since September 2013, Saint-Gobain has become a key partner of LEED®. USGBC released a new version of the LEED® certification, called V4, at the end of 2013. This version will be the only one on the market from July 2015.1 Source: www.usgbc.org/projectsLEED® ratingsThere are four rating systems that address multiple project types:• Building Design and Construction• Interior Design and Construction• Building Operations and Maintenance• Neighbourhood DevelopmentLEED® v4 for Building Design and Construction (BD +C) is used as a reference in this brochure; it includes the following specific rating systems. Points can vary according to each criterion and specific rating systems:• LEED® v4 BD+C: New Construction • LEED® v4 BD+C: Core and Shell• LEED® v4 BD+C: Schools• LEED® v4 BD+C: Retail• LEED® v4 BD+C: Data Centres• LEED® v4 BD+C: Warehouses and Distribution Centres• LEED® v4 BD+C: Hospitality• LEED® v4 BD+C: HealthcareThe LEED®v4 rating system Building Design and Construction (BD+C) for New Construction and Major Renovation has eight major categories, five of which can be improved using the plaster and plasterboard solutions from Gyproc in the design of the building.To find out more about Gyproc and LEED visit gyproc.ieLEED® Certification36 | GYPROC FACADE SYSTEM
SPECIFICATION SALES MANAGERSNational Specification ManagerBarry Hennessy +353 (0)42 969 8100 barry.hennessy@saint-gobain.comNorthern RegionMark McCormick +44 (0)78 554 67301 mark.mccormick@saint-gobain.comSouth Dublin, Kildare & WicklowGeorge McGreal +353 (0)86 026 2740 george.mcgreal@saint-gobain.comBorder, West & MidlandsMark Gunning+353 (0)86 774 4438 Mark.gunning@saint-gobain.comDublin North, Louth & MeathLara Gomes Garcia +353 (0)86 136 3027 Lara.gomes@saint-gobain.comMid-West, South-East & South-WestJe Gallagher +353 (0)86 774 4437 je.gallagher@saint-gobain.comGYPROC FACADE SYSTEM | 37
SAINT-GOBAIN SOLUTIONS Unit 4, Kilcarbery Business Park, Nangor Road, Dublin 22 D22 R2Y7Telephone: 01 629 8400 Email: SGSolutionsIrl@saint-gobain.comJuly 2025Gyproc, Gypframe and Glasroc are all registered trade names of Saint-Gobain Construction Products (Irl) Limited. Isover is a registered trade name of Saint-Gobain. Saint-Gobain Construction Products (Irl) Limited reserves the right to revise product specifications without notice. The information in this document was correct to the best of our knowledge at the time of publication. It is the user’s responsibility to ensure that it remains current prior to use. The information in this document is for guidance only and should not be read in isolation. Users should read and familiarise themselves with all the information contained in this document and ensure that they are fully conversant with the products and systems being used, before subsequent specification or installation. For a comprehensive and up-to-date library of information visit the Gyproc website at: www.gyproc.ieSAINT-GOBAIN SOLUTIONS Unit 4, Kilcarbery Business Park, Nangor Road, Dublin 22 D22 R2Y7Telephone: 01 629 8400 Email: SGSolutionsIrl@saint-gobain.comSAINT-GOBAIN SOLUTIONS Unit 4, Kilcarbery Business Park, Nangor Road, Dublin 22 D22 R2Y7Telephone: 01 629 8400 Email: SGSolutionsIrl@saint-gobain.com@SaintGobainIrelandSaint-GobainIE