Return to flip book view

Fabral Blue Book

Page 1

STANDARD DETAILS FOR METAL ROOFING AND SIDING AGRICULTURAL LIGHT COMMERCIAL RESIDENTIAL THE BLUE BOOK

Page 2

Due to Product improvements changes and other factors Fabral reserves the right to change or delete information herein without prior notice or obligation to make changes in products previously purchased The details and written instructions described in this manual are suggested installation methods to ensure a quality application of our products and should be considered as a guideline only FABRAL recognizes that installation techniques can vary based upon builder and geographical preferences and that there are other acceptable ways to install our products Fabral com

Page 3

TABLE OF CONTENTS Introduction 2 Fabral Core 3 Installation Instructions 4 5 Steel Panel Profiles 6 8 Aluminum Panel Profiles 9 Estimating Roof Types 10 Load Tables Testing 11 Building Details Post Frame 12 Residential 13 Post Frame Flashing Details Endlap Rain Carrying Table 14 Flashings Trim Post Frame 15 18 Residential 19 Mighti Rib 20 General Notes 21 System Components 22 23 Accessories 24 25 Trim Details Post Frame Eave Box Eave 26 Vented Eave Endwall 27 Endwall Notched Sidewall 28 Dormer Valley Valley 29 Gambrel Transition 30 Box Gable 31 Gables 32 Flying Gable Detail Monoslope Ridge 33 Ridge Peak Non Vented Vented Ridge 34 Alternate Vented Ridge Base Guard 35 Door Header Door Jamb 36 Door Jambs 37 Overhead Door Jambs 38 Sliding Door Jamb Header Base 39 Window Sill Header Jamb Translucent Panel 40 Inside Corner Outside Corners 41 Residential Vented Eave Eave 42 Endwall Sidewall 43 Valley Dormer Valley 44 Gambrel Transition 45 Pipe Boot Skylight 46 Skylight Section A A B B 47 Chimney Details 48 Chimney Endwall Ridge Hip 49 Vented Ridge Gable 50 Paint System Warranties 51 Complete Contact Information 52

Page 4

INTRODUCTION The Right Tools This Standard Details Manual AKA the Blue Book is the right tool to have at your fingertips By knowing you have access to all of the right information from proper storage and installation instructions to trim and flashing details you can be confident installing your Fabral materials In addition the Blue Book references the complete system components and accessories allowing you plan ahead Use the Blue Book and call us when further support is needed AGRICULTURAL Fabral is the solution for your agricultural applications We know that your barns and buildings must stand up to all weather conditions and last through the years LIGHT COMMERCIAL For your light commercial needs Fabral offers metal roofing and siding to match the various building types RESIDENTIAL Homeowners feel proud and confident with Fabral metal roofing for the durability and sophisticated appearance 2 Fabral com

Page 5

You challenge us And we like it Your vision for a building and what you want to achieve makes us think harder It d be easy to say That won t work Instead we go with Let s see what we can do As the leading provider of metal for building envelope solutions we push the envelope We like it when you bring us a problem because we know we ll find the solution We have the products the manufacturing and the know how We offer everything you need for the total building envelope solution At our core we relish a challenge CUSTOMER CARE SYSTEM SUPPORT EDUCATION PROJECT CONSULTING TECHNICAL SUPPORT To learn more contact us at Fabral com 3

Page 6

INSTALLATION INSTRUCTIONS Building Design and Construction In order to ensure the anticipated performance and longevity protect metal panels from potentially corrosive situations and materials When treated lumber will be in direct contact with metal panels or flashings please note the following Galvanized steel is compatible with the CCA Chromated Copper Arsenate pressure treated lumber that was predominantly used before 2004 but not with the older Penta treated lumber or the new ACQ Alkaline Copper Quartenary CA Copper Azole or CBA Copper Boron Azole Stainless steel or other special treated fasteners should be used into these non compatible pressure treated lumbers Aluminum must be separated from contact with all treated wood since the soluble copper in the preservative is corrosive to aluminum Likewise dissimilar metals also require a protective barrier between them to prevent galvanic corrosion Request FABRAL Technical Bulletins 803 106 and 107 for more information on treated lumber and dissimilar metals PLASTIC BUILDERS FELT BITUMINOUS PAINT CAULKING OR GASKET MATERIAL MAY BE USED TO SEPARATE PANELS FROM TREATED WOOD AND DISSIMILAR METALS When using aluminum panels in direct contact with steel use a separator as described above and fasten with Stainless Steel screws Fertilizer lime acids feeds manure soils and many other compounds also cause corrosion in metal panels Contact between metal panels and any potentially corrosive materials should be prevented Porous insulation materials may absorb and retain moisture and should not be used in direct contact with metal panels Use a vapor barrier such as polyethylene plastic or 30 lb felt to prevent moisture from contacting both the insulation and the metal panel FABRAL s translucent panels are intended for siding applications only In all situations foot traffic should be avoided on translucent panels Translucent panels used in roofing applications will break down in a short time and cause staining and premature corrosion of the metal panels below If used on roofs apply butyl caulking to separate the fiberglass panels from the metal Translucent panels should be cleaned and sealed regularly as recommended by the translucent panel manufacturer Purlins Girts and Roof Deck The substructure to which the metal panels are fastened must be properly spaced and sufficiently thick to provide a roof or wall system able to meet required design loads A 2 nominal lumber thickness or 1 nominal thickness are both acceptable purlins If snow guards are to be installed in the future a 2 x 8 purlin can be installed in the area for snow guard installation Call engineering for locations of 2 x 8 purlins When using purlins FABRAL recommends a maximum spacing of 24 on center note that 5V requires solid decking Pullout values decrease if the fasteners protrude completely through the purlins Kiln dried softwood is recommended for purlins or decking pine fir hemlock and spruce Hardwoods are difficult to fasten into without splitting and contain tannic acids that are corrosive to metal panels Green non kiln dried lumber may warp twist and shrink as the wood seasons fully causing waviness in the panels as well as loosening and leaking of the fasteners Solid decking is highly recommended for all residential applications When using solid decking or sheathing always use 30 lb felt or underlayment and plan on using closer fastener spacing and larger diameter 14 screws Refer to the tables on page 31 On re roofing projects where the condition of the old decking is in question or where existing shingles will be left in place new 2x4 or 1x4 purlins should be fastened through the decking and into the rafters This will provide a solid framework for attaching the metal panels For more detailed information on re roofing applications consult FABRAL Technical Bulletin 721 Re Roofing With Metal Load tables are available for all FABRAL panels contact FABRAL for additional information Roofing Panel sidelaps should face away from wind driven rain To accomplish this begin by installing the first sheet square with the eave and gable at the down wind end of the roof farthest away from the source of prevailing winds or away from the primary viewing location In applications requiring a panel endlap please refer to the detailed instructions in this booklet For best results lap panels as shown and install in the indicated sequence ALL ENDLAPS REQUIRE SEALANT WHEN WEATHER TIGHTNESS IS CRITICAL USE SEALANT TAPE IN ALL SIDELAPS To provide a drip edge allow an overhang of 1 to 2 inches at the eave At the gable edge use a gable or sidewall flashing This will keep weather out prevent lifting in high winds and provide a neat finished appearance The trim and roofing sheet should be fastened every 12 to 24 inches along the gable edge Do not step on panel ribs or on trim pieces to prevent kinking Roof Pitch The metal roofing panels shown in this manual require a minimum slope of 2 per foot to ensure proper drainage Refer to the rain carrying table in this booklet for the maximum allowable panel length per slope that will provide adequate drainage For longer slopes and lower roof pitches contact FABRAL for other suitable profiles Bending and Bowing Aluminum and Steel roofing and siding sheets are rollformed from hardened tempered metal for maximum strength If a sheet must be bent a gentle 90 degree bend is the maximum recommended Metal should not be re bent once it has been formed nor should it be folded back on itself When a metal roofing sheet must be installed on a curved roof screws should be installed at every overlapping rib at the sheet ends to resist the natural tendency of the metal to spring back The standard fastening pattern is permitted over the rest of the sheet When installing the metal panels shown in this booklet over a curved arch the minimum radius of the arch is 18 for aluminum panels and 24 for steel panels Use sealant tape or butyl caulking at all sidelaps and endlaps Additional care and fasteners must be provided when securing the top and bottom purlins on an arched rafter building to prevent the curved panels from pulling the purlins loose from the rafters Ring shank pole barn nails heavy wood screws lag screws or bolts are often used for attaching these purlins Siding Siding should be installed using the standard fastening and overlap patterns to ensure optimum performance For strong neat corners use hemmed corner flashings DO NOT RUN SIDING SHEETS ALL THE WAY TO THE GROUND INSTEAD PROVIDE A PROTECTIVE BASE OF CONCRETE MASONRY TREATED WOOD OR SIMILAR MATERIAL AND TERMINATE THE SIDING SHEETS 6 ABOVE GRADE If siding sheets are installed horizontally use sealant tape or butyl caulking at the vertical laps to ensure weather tight joints Install panels from the bottom up so that water is directed away from and not into the lap joints

Page 7

Fastening FABRAL can supply either screws or nails for fastening into dimension lumber Always use screws with solid sheathing Screws for use with steel panels are galvanized and then coated with an organic polymer for optimum corrosion resistance For best results with aluminum panels use 300 series stainless steel screws guidelines for compliance with all safety requirements Do Not walk on panels until all the fasteners are installed Metal roofing panels are slippery when wet dusty frosty or oily Do Not attempt to walk on a metal roof under these conditions Wear soft soled shoes to improve traction and to minimize damage to the paint finish Always be aware of your position on the roof relative to any roof openings roof edges co workers and penetrations Installing metal panels or flashings on a windy day can be dangerous and should be avoided if possible Under Driven Cutting Aluminum Panels To make a cut parallel to the ribs score the panel deeply with a sharp utility knife and bend back and forth along the score breaking the metal off cleanly For cuts across the ribs use straight cut snips electric or pneumatic shears a portable profile shear or an electric nibbler Some installers prefer using a circular saw with a metal cutting blade a fine tooth hardwood blade or a standard combination blade reversed in the saw works also Light oil or soap on the blade will make cutting easier Correct Over Driven Wood screws with combination metal and neoprene washers should be installed in the flat area of the panel adjacent to the ribs and tightened such that the washer is compressed as illustrated above This will ensure a lasting leak proof seal REMOVE ANY METAL FILINGS CREATED BY THE DRILLING ACTION OF THE SCREWS OR PRE DRILLING OF THE HOLES TO AVOID RUST STAINING ON THE PANEL SURFACE Refer to the fastening schedules in this booklet for the correct fastener locations Panels adhered with CondenStop FULL LENGTH PANELS FROM EAVE TO RIDGE ARE RECOMMENDED EAVE OVERHANGS VALLEYS AND ANY OTHER EDGES EXPOSED TO THE WEATHER SHOULD BE PAINTED TO SEAL MICROFIBERS FROM ABSORBING MOISTURE FROM THE OUTSIDE WET STACK STORAGE STILL APPLIES TO PANELS WITH CONDENSTOP APPLIED PLEASE STORE PROPERLY BY COVERING AND TILTING ONE END IT S ALWAYS BEST IF THEY CAN BE STORED INSIDE IF NOT BEING IMMEDIATELY INSTALLED Flashing and Trim Always begin flashing installation from the bottom and work up so that upper flashings are lapped on top of lower flashings This will prevent moisture from leaking under the flashings and into the structure Endlap flashings a minimum of 6 and seal the lap joints with sealant Extend flashings 4 6 beyond the building cut along the bend lines apply sealant and fold the side flaps in and the top flaps down to cap off the ends Secure with pop rivets or stitch screws Some roof conditions such as valleys may require a longer endlap and or a larger flashing to properly drain moisture from the roof Factors that influence flashing size shape and endlap requirements include roof pitch roof geometry slope length and climatic factors such as heavy snowfall or rainfall Whenever possible begin trim installation at the downwind end of the roof farthest away from the source of prevailing winds to allow flashing laps to face away from wind driven rain Refer to the details in this book for the proper location of fasteners and sealants The flashings and trims shown in this book are standard parts Custom trims are available to meet your specific design needs If you need a special trim please furnish a drawing of the desired shape including dimensions and angles to your Fabral dealer to obtain pricing and availability Refer to the SMACNA Architectural Sheet Metal Manual for additional information about detailing and installing flashings Safety Always work safely when installing metal products and use extreme caution on the roof at all times Wear gloves and safety glasses to reduce the risk of injury and use hearing protection when operating power tools Always be sure that ladders are safely positioned and properly secured Safety harnesses or other special equipment may be required be sure to Consult OSHA Cutting and Drilling Steel Panels Steel panels may be cut with metal snips electric or pneumatic shears a portable profile shear or an electric nibbler Some installers prefer using a circular saw to cut metal panels Do Not use self consuming abrasive blades because of the following 1 Abrasive blades burn the paint and galvanizing at the cut edge leaving edges that are jagged and unsightly and rust more quickly 2 Abrasive blades produce hot metal filings that embed in the paint and cause rust marks on the face of the panel If saw cutting cannot be avoided select a carbide tipped blade specially designed for cutting light gage ferrous metal panels These blades are now available at many home centers and lumber yards 1 All saw cut panels must be turned face down and cut in a location down wind and well away from the building and other panels to avoid embedment of metal filings on other panels 2 All saw cut panels must be thoroughly wiped to ensure the removal of all metal filings Pre drilling wall panels gives uniform alignment of screw rows BE SURE TO REMOVE ANY FILINGS ONCE PANELS ARE INSTALLED TO AVOID RUST MARKS FROM THE FILINGS Building Maintenance A metal roof should be inspected annually and cleaned as necessary to maintain its beauty and performance Any debris or residue including leaves twigs and dust should be cleaned off promptly to prevent moisture entrapment against the metal which may lead to finish deterioration or premature corrosion Flashings may need to be re sealed periodically in order to maintain optimum weathertightness Proper Storage Store metal panels indoors when possible if outdoors cover and elevate Elevate one side higher for water drainage Never cover in plastic us a tarp that can breath Allow for air circulation If a bundle gets wet break bands and separate sheets allow sheets to dry completely and only restack if completely dry Product should be stored for a maximum of 2 4 weeks before being installed Spray Foam Insulation When insulating metal with spray foam insulation the first application layer should be getting the insulation behind all framing members When completing the insulation ensure the spray foam is installed in 2 thick layers maximum until desired thickness is achieved

Page 8

STEEL PANELS Grandrib 3 3 4 Formed Formed Width 37373 4 Width 36 Coverage 36 Coverage 9 9 3 4 3 4 S TTTTA E SN NR RE ESCREW AP PW WPATTERNS ER RC CS S SNRE TTAP LIAN NAIL PATTERNS ggIntermediate nniiddiiS ssnniillrruuPurlins P eettaaiid rreettnnII All Siding S llllA A ddnnaaRoof P ffooooR Rand deem m stroSupports ppuS llA All ffooooR aallddnnE ddnnaa sseevvaaE Eavesssnand Endlaps Purlins niillrruuP P R s sppRoof E E 80 screws per square or 1 pound of nails per square See page 11 for a load table TrustiRib SNRENAIL TTAPPATTERNS LIAN sAll troSupports ppuS llA S TTTTA E SN NR RE E AP PW WPATTERNS ER RC CS S SCREW 3 4 Formed Width Width 37 3 4 37Formed 36 Coverage 36 Coverage 9 9 ggIntermediate nniiddiiS ssnniillrrPurlins uuP eettaaAll iiddeeSiding m S llllA A ddnnaaRoof P ffooooR R mrreettnnII and nniillrruuEndlaps P ppaallddnnPurlins E Eavesssand P ffooooR R ssRoof E ddnnaa sseevvaaE E 3 4 3 4 Not all profiles are available in all areas Please contact Fabral for availability 6 Fabral com

Page 9

STEEL PANELS NAIL PATTERN Mighti Rib SCREW PATTERN ROOFING EAVES RIDGES AND ENDLAPS 39 Formed Width 36 Coverage ROOFING INTERMEDIATE SUPPORTS SIDING ALL SUPPORTS Purlin Bearing Leg 12 1 1 4 Please see Mighti Rib specific trims on page 20 5V Crimp NAIL PATTERN USE ON SOLID DECKING ROOFING EAVES RIDGES AND ENDLAPS ROOFING INTERMEDIATE SUPPORTS SCREW PATTERN Formed Width 26 26 Formed Width 24 Coverage 24 Coverage 1 2 1 2 1 1 12 12 1 1 1 2 1 2 ROOFING EAVES RIDGES AND ENDLAPS ROOFING INTERMEDIATE SUPPORTS SIDING ALL SUPPORTS ProClad Sidelap Detail SCREW PATTERNS Intermediate Roof Purlins and All Siding 36 Coverage 9 Eaves and Endlaps Roof Purlins 5 8 1 1 4 Corrugated 26 Formed Width 24 Coverage 1 1 4 SCREW PATTERN 1 4 2 1 2 Corrugated NAIL PATTERN ROOFING EAVES RIDGES AND ENDLAPS ROOFING EAVES RIDGES AND ENDLAPS ROOFING INTERMEDIATE SUPPORTS SIDING ALL SUPPORTS ROOFING INTERMEDIATE SUPPORTS SIDING ALL SUPPORTS NAIL PATTERN SCREW PATTERN ROOFING EAVES RIDGES AND ENDLAPS ROOFING EAVES RIDGES AND ENDLAPS ROOFING INTERMEDIATE SUPPORTS ROOFING INTERMEDIATE SUPPORTS SIDING ALL SUPPORTS 26 Formed Width Coverage Varies 2 2 3 SIDING ALL SUPPORTS Note Roofing panels require side caps cover two corrugations 1 2 Wall application 24 coverage with 1 rib overlap Roof application 21 1 3 coverage with 2 rib overlap Not all profiles are available in all areas Please contact Fabral for availability 7

Page 10

STEEL PANELS Prime Rib 38 Formed Width 36 Coverage 1 3 1 1 2 Grandbeam 1 Formed Width 424 36 Coverage 9 1 2 7 8 4 9 416 100 3 18 Note Grandbeam has panel specific flashings available 134 134 StrongClad 36 5 8 9 Not all profiles are available in all areas Please contact Fabral for availability 8 Fabral com

Page 11

ALUMINUM PANELS Grandrib 3 Recommended as a Liner Panel only ROOFING EAVES RIDGES AND ENDLAPS ROOFING INTERMEDIATE SUPPORTS SIDING ALL SUPPORTS 3 4 Formed Width Width 37 3 4 37Formed 36 Coverage 36 Coverage 9 9 3 4 3 4 Strongrib 018 Aluminum Plain and Painted White SCREW PATTERN Correct Strongrib Sidelap BUTYL SEALANT LOCATION OPTIONAL FIELD APPLIED PURLIN BEARING LEG 3 4 9 36 Coverage 37 3 4 Formed Width INTERMEDIATE ROOF PURLINS AND ALL SIDING EAVE AND ENDLAPS ROOF PURLINS 2 1 2 Fabrib ROOFING EAVES RIDGES AND ENDLAPS ROOFING INTERMEDIATE SUPPORTS SIDING ALL SUPPORTS 51 3 16 Overall 2 2 3 3 4 48 Coverage AluTwin Other widths available 50 1 4 Overall 48 Coverage 8 2 1 2 Corrugated Formed Width Varies Coverage Varies 2 2 3 7 16 1 2 ROOFING EAVES RIDGES AND ENDLAPS ROOFING EAVES RIDGES AND ENDLAPS ROOFING INTERMEDIATE SUPPORTS SIDING ALL SUPPORTS ROOFING INTERMEDIATE SUPPORTS SIDING ALL SUPPORTS Not all profiles are available in all areas Please contact Fabral for availability Lengths greater than 16 on aluminum panels are not recommended due to expansion and contraction 9

Page 12

ESTIMATING ROOF TYPES Estimating Metal Roofing Siding Flashings Panel lengths are to be determined by the truss top chord or actual field measurements Remember to add for overhangs at the eaves subtract for a gap at the ridge Siding should be kept up away from the ground with a skirt board Number of Panels The coverage of the panel being used will determine the number of panels at a length i e 3 coverage panel on a 30 ft long building would require 10 panels on each side of the ridge or 20 panels at the particular length Gambrel Roof Horizontal Measurement to a Roof Divide the building width in half then multiply by the slope factor i e 40 wide building with 4 12 slope 40 divided by 2 equals 20 times 1 054 equals 21 1 in slope dimension Allow for 1 2 to 1 gap at peak and 1 to 2 eave overhang Roof Pitch Slope Factor 3 12 4 12 5 12 6 12 8 12 10 12 12 12 1 031 1 054 1 083 1 120 1 202 1 302 1 414 Transition Roof Flashing Conditions Roof Eave Ridge Gable Sidewall Endwall Valley Hip Transition Gambrel Soffits Siding Base Perimeter Corners Inside Corners Man Doors Windows Sliding Doors Overhead Doors Please contact Fabral s Engineering Department for all your estimating specification needs 800 477 2741 717 735 1257 Fax 10 Fabral com Hip Roof

Page 13

LOAD TABLES TESTING The Above Loads and fastener quantities are based on the standard fasening schedule shown on page 6 of this book with the fastener having an embedment depth of 1 into the solid wood or penetrating the plywood or OSB Contact FABRAL for additional design information on our products UL RATINGS UL790 Class A Fire Rating applies to all Steel panels 29 ga and thicker and all Aluminum panels 032 and thicker UL2218 Class 4 Hail Impact Rating applies to all Steel panels 29 ga and thicker and all Aluminum panels 032 and thicker 11

Page 14

12 Fabral com Zee p 18 Base Guard p 35 Drip Cap p 36 J Channel Doors Windows p 36 Gable p 31 Endwall p 27 Inside Corner p 41 Ridge Peak p 34 BUILDING DETAILS POST FRAME Sidewall p 28 Sliding Door Track Cover p 39 Outside Corner p 41 Eave p 26

Page 15

RIDGE PEAK CHIMNEY VALLEY ENDWALL PIPE PENETRATION TRANSITION SIDEWALL EAVE SKYLIGHT GABLE RAKE HIP RESIDENTIAL exposed fastener panel BUILDING DETAILS 1 Determine the thickness and type of substrate to be used to support the metal roofing Solid decking is highly recommended for all residential applications i e plywood OSB 2 Refer to the Load Span tables to select the proper fastener and spacing to meet loads on your structure Nails are NOT recommended for residential applications 3 Consult local building codes and restrictions to determine acceptable methods of construction for residential applications in your area 4 Solid decking with 30 felt or synthetic underlayment for residential applications is recommended Ice water shield or similar self adhesive membrane is recommended at all valleys dormers chimneys transitions skylights and other critical areas 5 When re roofing with metal panels over an existing shingle roof metal panels may be installed directly over shingles with underlayment or 2x4 purlins or 1x4 furring strips 6 Zip board sheathing which has a built in vapor barrier is an acceptable substrate and vapor barrier 7 Request Fabral s technical bulletins 720 and 721 for more details on residential roofing 13

Page 16

POST FRAME FLASHING DETAILS ENDLAP RAIN CARRYING TABLES 1 Apply 3 32 x 1 2 butyl endlap sealant on bottom panel just below centerline of purlin see endlap diagram for location on panel 1 2 Apply sidelap sealant on panel 1 and connect to endlap sealant 3 Place panel 2 so it overlaps panel 1 12 as shown Install screws per endlap fastening pattern 4 Apply sidelap sealant on panel 2 to connect to sidelap sealant of panel 1 5 Place panel 3 over sidelap of 1 and 2 6 Apply endlap sealant on panel 3 7 Apply sidelap sealant on panel 3 and connect with endlap sealant 8 Place panel 4 over endlap of panel 3 Install screws per endlap pattern 9 Repeat sequence for entire roof D ALUMINUM All runs or steel 3 runs ROOF PANEL STEP 1 CONTINUOUS BEAD OF 3 32 x 1 2 BUTYL SEALANT TAPE DOWN SLOPE 6 1 2 2 OVERLAPPING FROM PURLIN EDGE 3 1 2 STEEL 2 runs STEP 2 10 To Sealant FASTENERS ENDLAP PATTERN ROOF PANEL DOWN SLOPE 6 1 2 2 OVERLAPPING FROM PURLIN EDGE 12 Total Lap PR EV ENDLAP TAPE ALIGN WITH PURLIN EDGE INSTALLATION SEQUENCE FOR STRONGRIB GRANDRIB 3 5V CRIMP ALU TWIN ENDLAP TAPE THIS EDGE PURLIN 3 1 2 5 1 4 2 EAVE OVERHANG 1 TO 2 IN L ST FE AR TE ND Roof Slope Minimum Slope 2 1 2 12 3 12 3 1 2 12 4 12 5 12 6 12 Grandrib 3 2 1 2 12 58 61 64 67 73 78 Prime Rib 2 1 2 12 39 41 43 45 49 53 5V 2 1 2 12 43 45 47 49 54 58 2 1 2 Corrugated 2 1 2 12 28 29 31 32 35 38 1 1 4 Corrugated 2 1 2 12 16 16 17 18 20 21 Alutwin 2 1 2 12 37 39 41 43 46 50 Fabrib 2 1 2 12 32 34 36 38 41 44 Notes For Rain Carrying Tables 1 All values based on a 1 hour duration storm of 4 hr intensity 2 Values represent the point at which the panel ribs will flood 3 Size and frequency of penetrations can greatly reduce the amount of water removed from a roof 4 All panel endlaps must be caulked 5 When weather tightness is crtical use sealant tape in all sidelaps 14 Fabral com ET SKIRT BOARD OF TREATED LUMBER OR FOUNDATION OF BLOCK 12 TO 18 FROM GROUND LEVEL ALLOWABLE PANEL LENGTHS ft ALONG THE SLOPE FOR 4 RAINFALL PER HOUR Panel Name ND SIDELAP TAP THIS EDG 3 3 WHEN INSTALLING 2 1 2 OR 1 1 4 CORRUGATED ROOFING USE INSTALLATION SEQUENCE AS SHOWN WI END 2 5 1 ING 4 SIDELAP TAPE THIS EDGE SIDELAP TAPE THIS EDGE AIL

Page 17

STANDARD POST FRAME FLASHINGS TRIMS All flashing is 10 6 in length available in steel aluminum unless otherwise noted Please contact Fabral for specifics on the trim available in your area AJ2 Jamb Trim AJ3 J Channel AJ4 Jamb Trim AJ6 Jamb Trim AJ5 Jamb Trim RJ8 J Channel RJ9 F J Trim 45 Liner Channel F J Trim PJFB One Piece Door Trim F J 10 Trim Midwest Only 15

Page 18

POST FRAME FLASHINGS TRIMS AG4 Gable AC1 Corner Longer Lengths Available AG1 Gable Rake Longer Lengths Available AC3 Corner Longer Lengths Available AC2 Inside Corner AC4 Corner Longer Lengths Available 1 1 16 RG1 Residential Gable WG1 Residential Gable Longer Lengths Available AH3 Double Door Track Cover 16 Fabral com AH2 Door Track Cover Longer Lengths Available AH4 Door Track Cover AH5 Door Track Cover

Page 19

POST FRAME FLASHINGS TRIMS AH6 Door Track Cover AR3 Ridge Cap AR3 w Versavent RX 10 Ridge Cap SB Snow Break Solid Deck RR1 Universal Ridge Hip Flash CP1 Monoslope Ridge SB1 Snow Break 2x4 Purlins 2 1 8 1 1 2 3 4 1 1 2 3 4 AT1 Transition Flash CE1 Denver Eave AT2 Gambrel Flash ASW1 Sidewall Endwall Flash AEWN4 Notched Endwall Flash Available in 40 1 2 length only AGRN4 Notched Gambrel Flash Available in 40 1 2 length only Notched 17

Page 20

POST FRAME FLASHINGS TRIMS Other sizes are available upon request AL6 Angle Flashing AL2 3 4 5 Angle Flashing 2 3 16 AL7 Angle Flashing Longer Lengths Available AL9 Angle Flashing AL8 Angle Flashing ABG1 Base Guard AL10 Angle Flashing 203 Box Base AB1 Soffit Box AZ2 Zee AB3 Soffit Box AD1 Drip Cap 7 1 2 AB2 Soffit Box 7 1 4 AB4 Soffit Box 2 1 2 RV1 Valley Flash AE1 Eave Flash RV2 W Valley Flash 18 Fabral com RE1 Residential Eave

Page 21

STANDARD RESIDENTIAL exposed fastener panel FLASHINGS TRIMS All flashing is 10 6 in length available in steel aluminum unless otherwise noted Please contact Fabral for specifics on the trim available in your area 1 1 16 RG1 Residential Gable CE1 Denver Eave AR3 Ridge Cap RR1 Universal Ridge Hip Flash RE1 Residential Eave ASW1 Sidewall Endwall Flash AG4 Gable WG1 Residential Gable RV1 Valley Flash RV2 W Valley Flash AT1 Transition Flash CP1 Monoslope Ridge AT2 Gambrel Flash 19

Page 22

POST FRAME FLASHINGS TRIMS STANDARD MIGHTI RIB FLASHINGS TRIMS All Mighti Rib specific flashing is 10 6 in length available in steel unless otherwise noted Please contact Fabral for specifics on the trim available in your area FH1 Head Sill Flashing FE2 Eave Flashing FR4 Ridge Cap FT1 Endwall Transition Flash 5 1 11 16 5 8 5 FC4 Inside Corner Flash 1 3 16 FC3 Gable Outside Corner Flash FZ4 Zee Flash FJ3 J Channel Flashing 20 Fabral com 1 3 8 1 3 8 Modified PJFB Trim Modified F J Trim

Page 23

GENERAL NOTES 21

Page 24

SYSTEM COMPONENTS SNOW GUARDS Exposed Fastener Panel Grandrib 3 Mighti Rib TrustiRib 5V Crimp 2 1 2 Corrugated ProClad MINI CLSM X X X X X X Available in premium polycarbonate plastic with UV stabilizers Provides maximum protection at a moderate price point Two to one base to blade ratio 4 5 sq in and gusseted blade snow pocket Typically installed by adhering to and mechanically fastened to the roofing panel Snow Boss Snow Guards 640 Traditional Shape solid cast aluminum Applied to the mid panel on all standing batten and flat seam roofs Typically installed by adhering to and mechanically fastened to the roofing panel Low profile protection ideal for 1 x 2 purlins Non Stock item inquire for lead time Fabral com 640 X X X X X X X X 20 SM X X MINI Clear Snow Guard 22 CLSR X X CL Snow Guard Available in premium polycarbonate plastic with UV stabilizers Unique vent rib systems allows for adhesive out gassing Three to one base to blade ratio adds significantly to strength SM Snow Guard Available in cast aluminum Typically installed by adhering to and mechanically fastened to the roofing panel Very effective where there are no suitable seams Non Stock item inquire for lead time

Page 25

SYSTEM COMPONENTS FASTENERS For more information review Fabral s installation manuals 10 WoodTite High Low 14 10 WoodTite Use with dimensional lumber Use to fasten metal to plywood or OSB Available in 1 1 1 2 2 2 1 2 and 3 Use for trim attachment 1 4 hex head EPDM metal washer Available in 1 1 1 2 and 2 Oxyseal Long Life Coating 5 16 hex head EPDM metal washer Plain or Painted Oxyseal Long Life Coating 250 bag Plain or Painted 250 bag 10 16 302 Series Stainless Steel 10 14 410 Stainless Steel Use for high corrosive environments Use with 26 gauge or thinner to avoid pre drilling Use with ALUMINUM panels NOT as corrosive resistant as the 300 Series Available in 1 1 1 2 and 2 Steel is harder than 300 Series 1 4 hex head EPDM metal washer Available in 1 1 1 2 and 2 Use with treated lumber 1 4 hex head EPDM metal washer Plain or Painted Use with steel panels installed on treated lumber 250 bag Plain or Painted 250 bag 10 14 Ultimate WoodTite 12 x 3 4 Stitch Screw Use with ALL panels Available in 1 1 1 2 2 2 1 2 and 3 1 4 case zinc hex head Use with STEEL panels Hex head washer all one piece Used to stitch sidelaps for exposed fastener panels Plain Used for miscellaneous metal to metal attachments 250 bag Used for attachment of trim to top of seam for screw flange panels 1 4 hex head EPDM metal washer Plain or Painted 250 bag UNDERLAYMENT 30 Year Peel Stick PRODUCT SPECS 50 Year Synthetic PRODUCT SPECS Watertight Self Sealing Underlayment Installation requires mechanical fasteners Asphalt to Asphalt Lap System Roll Size 4 W x 250 L Roll Size 3 W x 72 L Minimum Thickness 75mm Minimum Thickness 1 1mm Square Ft Per Roll 1 000 Square Ft Per Roll 200 36 rolls per pallet CONDENSTOP Stop condensation with Fabral factory applied CondenStop CondenStop saves time and money with reduced labor costs and installation time versus other condensation barriers Easily and effectively prevent condensation and the problems caused by condensation by installing Fabral panels featuring CondenStop Protects assets and investments from moisture Can be used in place of traditional vapor retarders Adds to interior corrosion protection Light gray color enhances the indoor look of an open framing structure roof Available for Grandrib 3 painted panel offerings 23

Page 26

ACCESSORIES VENTING CLOSURES Ridge Cap Vent Specifications LP2 Closure Specifications Available for Grandrib 3 Mighti Rib Horizon S and Climaguard profiles LP2 Clousure Specifications Lower custom fit profile Moisture and pest barrier Non obtrusive appearance Reduces utility costs One person installation Venting factory applied to the ridge cap Save up to half of your installation time Non profile specific material Clean dust free installation Virtually NO WASTED material 1 1 2 x 3 material provides 17 sq inches lineal foot free area at the ridge Available attached to ridge cap as RX 10 version and as X 10 version for field installation not pre applied to ridge cap Profile Fit Vent Roll Specifications RV35 and RV100 Specifications Available for Grandrib 3 and 1 1 2 SSR profiles 10 66 sq in per lineal ft of ridge 5 33 side 10 long metal ridge vent Variety of colors available TRANSLUCENT PANELS Polycarbonate Grandrib 3 Clear White 8 10 12 Mighti Rib Clear White 12 24 Fabral com

Page 27

ACCESSORIES PIPE BOOTS EPDM Specifications Pipe Sizes Colors Gray and Black Up to 2500 F Base Diameter 7 3 4 10 3 4 16 1 2 Item No 3 5 8 min max 1 4 5 4 1 4 7 1 2 7 13 Silicon Specifications Color Orange Up to 4500 F Ranging for pipe sizes from 1 to 13 Larger sizes available upon request Retrofit boots also available sizes may vary FLAT SHEETS Product Specifications Used for field forming crickets around chimney skylights penetrations and special flashing as necessary 29 gauge painted and plain galvanized Full width 40 13 16 x 10 6 Grade 33 steel for better hemming forming and flexibility for field forming BACKER ROD Product Specifications Reduces the risk of oil canning Black foam with 5 8 diameter Available in individual boxes two rolls at 775 each Available in Midwest only SEALANT SEALER STRIP Sealant Specifications Sealant Tape Specifications 3 16 x 1 4 x 40 side lap 3 32 x 1 2 x 50 endlap 1 8 x 2 x 30 Waterproof sealant to fill gaps up to 1 UV resistant Permanent flexibility won t crack Standard color gray stocked Up to 50 additional color options non stocked Asphalt Impregnated Sealer Strip Specifications Use at valleys and hips 1 x 1 x 19 6 8 long 25

Page 28

POST FRAME TRIM DETAILS INSIDE CLOSURE BUTYL SEALANT TAPE TOP BOTTOM OF CLOSURE FASTENER PER STANDARD EAVE PATTERN OUTSIDE CLOSURE OPTIONAL ROOF PANEL FLASH CE 1 BUTYL SEALANT TAPE TOP BOTTOM OF CLOSURE FASTENER EVERY MAJOR RIB SIDING PANEL ROOF PURLIN POST EAVE ROOF TRUSS TOP PLATE INSIDE CLOSURE 3 EAVE PAGE 15 ROOF PANEL FASTENER PER STANDARD EAVE PATTERN FLASH CE 1 BUTYL SEALANT TAPE TOP BOTTOM OF CLOSURE EAVE PURLIN FLASH AB 1 AB 2 AB 3 OR AB 4 FASTENER FASTENER 24 O C MAX OUTSIDE CLOSURE OPTIONAL SIDING PANEL BUTYL SEALANT TAPE TOP BOTTOM OF CLOSURE TOP PLATE BOX EAVE 26 Fabral com

Page 29

POST FRAME TRIM DETAILS INSIDE CLOSURE BUTYL SEALANT TAPE TOP BOTTOM OF CLOSURE FASTENER PER STANDARD EAVE PATTERN FABRAL ALUMINUM SOFIT ROOF PANEL TOP PLATE FLASH CE 1 FASTENER 24 O C MAX F J TRIM SIDING PANEL FASTENER VENTED EAVE 5 VENTED EAVE PAGE 16 SIDING PANEL FASTENER PER STANDARD EAVE PATTERN GIRT INSIDE CLOSURE 2 FASTENER EVERY MAIN RIB FLASH ASW 1 BUTYL SEALANT TAPE TOP BOTTOM OF CLOSURE PURLIN ENDWALL ROOF PANEL OUSIDE CLOSURE 12 ENDWALL PAGE 21 View installation videos at Fabral com videos 27

Page 30

POST FRAME TRIM DETAILS ENDWALL NOTCHED SIDING PANEL FASTENER PER STANDARD EAVE PATTERN GIRT INSIDE CLOSURE 2 FASTENER EVERY MAIN RIB NOTCHED FLASH AEW N4 OR AEW N5 BUTYL SEALANT TAPE TOP BOTTOM OF CLOSURE PURLIN ROOF PANEL OUSIDE CLOSURE 13 ENDWALL NOTCHED PAGE 21 SIDING PANEL SIDEWALL FASTENER PER STANDARD EAVE PATTERN GIRT SEALER STRIP W BUTYL SEALANT TAPE FLASH ASW 1 FIELD BEND AS REQUIRED 2 FASTENER 24 O C MAX BUTYL SEALANT TAPE ROOF PANEL PURLIN SLOPING RAFTER ROOF PANEL 28 Fabral com

Page 31

POST FRAME TRIM DETAILS RIDGE TRIM DORMER VALLEY OUTSIDE CLOSURE TAPE SEALANT TOP BOTTOM ROOF PANEL UNIVERSAL CLOSURE TAPE SEALANT TOP BOTTOM LOWER VALLEY TRIM BUTYL TAPE SEALANT PEEL STICK UNDERLAYMENT UPPER VALLEY TRIM VALLEY LARGER VALLEYS MAY BE REQUIRED FOR LONG ROOF PANEL RUNS OR HEAVY SNOW AREAS CUT ROOF PANEL AS NECESSARY NOTE ROOF PANEL OMITTED ON OTHER SIDE OF RIDGE FOR CLARITY 39 DORMER VALLEYS PAGE 43 RV 2 SHOWN SCREWS EACH SIDE OF MAIN RIB EAVE ENDLAP PATTERN PEEL STICK SEALER STRIP 1 X 1 X 19 8 BLOCK CLOSURE FILL RIB VOIDS ROOF STRUCTURE SOLID 2X S OR PLYWOOD BUTYL SEALANT TOP BOTTOM OF SEALER STRIP NOTE VALLEY FLASH MUST HAVE SOLID SUPPORT View installation videos at Fabral com videos 29

Page 32

POST FRAME TRIM DETAILS FASTENER PER STANDARD EAVE PATTERN ROOF PANEL 2 FASTENER EVERY MAIN RIB BUTYL SEALANT TAPE TOP BOTTOM OF CLOSURE FLASH AT 2 OR AGR N4 GRANDRIB 3 INSIDE CLOSURE OUSIDE CLOSURE ROOF PANEL PURLIN GAMBREL BUTYL SEALANT TAPE TOP BOTTOM OF CLOSURE NOTE SPECIFY BOTH ROOF PITCHES WHEN ORDERING AT 2 FLASH AGRN 4 FOR GRANDRIB 3 AND AGRN 5 FOR STRONGRIB ARE FOR 3 12 TO 15 12 GAMBRELS 16 GAMBREL PAGE 23 BUTYL SEALANT TAPE TOP BOTTOM OF CLOSURE FASTENERS PER STANDARD EAVE PATTERN BUTYL SEALANT TAPE TOP BOTTOM OF CLOSURE INSIDE CLOSURE 2 FASTENER EVERY MAIN RIB FLASH AT 1 PURLIN ROOF PANEL OUSIDE CLOSURE NOTE SPECIFY BOTH ROOF PITCHES WHEN ORDERING AT 1 STANDARD IS 9 12 TO 3 12 TRANSITION 30 Fabral com 17 TRANSITION PAGE 23

Page 33

POST FRAME TRIM DETAILS BOX GABLE ROOF PANEL VERSION 1 FLASH AC 1 OR AC 4 ROOF PURLIN FASTENER 24 O C MAX FLASH AB 1 AB 2 AB 3 OR AB 4 BUTYL SEALANT TAPE FASTENER EVERY MAJOR RIB OUTSIDE CLOSURE OPTIONAL BUTYL SEALANT TAPE TOP BOTTOM OF SEALER STRIP END RAFTER FASTENER 24 O C MAX SIDING PANEL BUTYL SEALANT TAPE BOX GABLE VERSION 2 1 BOX GABLE PAGE X ROOF PANEL FLASH AG 1 ROOF PURLIN FLASH AB 1 AB 2 AB 3 OR AB 4 FASTENER EVERY MAJOR RIB FASTENER 24 O C MAX BUTYL SEALANT TAPE OUTSIDE CLOSURE OPTIONAL BUTYL SEALANT TAPE TOP BOTTOM OF SEALER STRIP FASTENER 24 O C MAX END RAFTER BUTYL SEALANT TAPE SIDING PANEL View installation videos at Fabral com videos 31

Page 34

POST FRAME TRIM DETAILS GABLE ROOF PANEL VERSION 1 FLASH AG 4 FASTENER 24 O C MAX BUTYL SEALANT TAPE PURLIN FASTENER EVERY MAJOR RIB SIDING PANEL END RAFTER OPTIONAL BUTYL SEALANT TAPE TOP AND BOTTOM OF SEALER STRIP OUTSIDE CLOSURE OPTIONAL GABLE VERSION 2 10 GABLE PAGE 19 ROOF PANEL FLASH AC 1 OR AC 4 FASTENER 24 O C MAX BUTYL SEALANT TAPE PURLIN FASTENER EVERY MAJOR RIB SIDING PANEL END RAFTER OPTIONAL BUTYL SEALANT TAPE TOP AND BOTTOM OF CLOSURE OUTSIDE CLOSURE OPTIONAL 32 Fabral com 9 GABLE PAGE 19

Page 35

POST FRAME TRIM DETAILS FLYING GABLE DETAIL OVERHANG ROOF PANELS TO CREATE APPROX 1 OVERHANG CE 1 UNDERLAYMENT BUTYL SEALANT TOP BOTTOM OF SEALER STRIP SEALER STRIP ASPHALT IMPREGNATED FASTENER FASCIA BOARD 2 FASTENER GABLE PAGE 20 11 FLYING EVERY MAIN RIB MONOSLOPE RIDGE CAP OUSIDE CLOSURE BUTYL SEALANT TAPE TOP BOTTOM OF CLOSURE SIDING UNDERLAYMENT ROOF STRUCTURE MONOSLOPE RIDGE SLOPING RAFTER View installation videos at Fabral com videos 33

Page 36

POST FRAME TRIM DETAILS NON VENTED RIDGE HIP AR 3 RIDGE FLASHING 2 LONG FASTENER EVERY MAIN RIB ROOF PANEL OUTSIDE CLOSURE ON HIP ROOFS USE 1 X 1 X19 8 SEALER STRIP RR 1 FLASHING BUTYL SEALANT TAPE TOP BOTTOM OF CLOSURE ROOF PURLIN 6 RIDGE PEAK NON VENTED PAGE 16 CUT 4 BEND RIDGE CAP FOR FINISHED END AR 3 RR 1 RIDGE FLASH VENTED RIDGE 2 LONG FASTENER EVERY MAIN RIB ROOF PANEL VERSAVENT RX 10 BUTYL SEALANT TAPE ROOF PURLIN 34 Fabral com

Page 37

POST FRAME TRIM DETAILS ALTERNATE VENTED RIDGE RR 1 RIDGE FLASH 2 1 2 FASTENER EVERY MAIN RIB ROOF PANEL FASTENER PER STANDARD PATTERN CORRUGATED VENT OPTIONAL J CHANNEL FOR SUPPORT UNDERLAYMENT ROOF PANEL ROOF STRUCTURE OUTSIDE CLOSURE WITH BUTYL SEALANT TOP AND BOTTOM BASE GUARD 8 ALT VENTED RIDGE PAGE 17 SIDING PANEL STAINLESS STEEL FASTENER PER STANDARD SIDING PATTERN INSIDE CLOSURE OPTIONAL FLASH ABG 1 BARRIER BETWEEN METAL AND ACQ TREATED LUMBER TREATED BASE PLANK FLOOR GRADE View installation videos at Fabral com videos 35

Page 38

POST FRAME TRIM DETAILS DOOR HEADER DOOR HEADER SIDING PANEL FASTENERS PER FASTENER PATTERN FLASH AD 1 FLASH AL 2 AL 3 AL 4 AL 5 OR AL 7 DOOR STOP DOOR GIRT DOOR JAMB VERSION 1 31 DOOR HEADER PAGE 28 SIDING PANEL DOOR JAMB FASTENERS PER FASTENER PATTERN DOOR STOP DOOR FLASH PJFB FASTENER 36 Fabral com

Page 39

POST FRAME TRIM DETAILS DOOR JAMB VERSION 2 GIRT SIDING PANEL FASTENERS PER FASTENER PATTERN DOOR JAMB BUTYL SEALANT TAPE FLASH AL 2 AL 3 AL 4 AL 5 OR AL 7 DEPENDING ON WIDTH OF JAMB DOOR STOP DOOR FLASH AJ 3 FASTENER DOOR JAMB VERSION 3 GIRT FASTENERS PER FASTENER PATTERN SIDING PANEL BUTYL SEALANT TAPE 24 DOOR JAMBSFASTENER PAGE 26 DOOR JAMB FLASH AJ 2 1 X 3 DOOR STOP DOOR View installation videos at Fabral com videos 37

Page 40

POST FRAME TRIM DETAILS OVERHEAD DOOR JAMBS VERSION 1 VERSION 3 GIRT DOOR JAMB GIRT FASTENERS PER FASTENER PATTERN FASTENERS PER FASTENER PATTERN POST POST OVERHEAD DOOR SIDING PANEL OVERHEAD DOOR SIDING PANEL DOOR JAMB DOOR JAMB DOOR JAMB FLASH AL 3 AL 4 AL 5 OR AL 7 BUTYL SEALANT TAPE FASTENER BUTYL SEALANT TAPE FASTENER FLASH AL 5 OR AL 7 1 X 3 GUIDE BUTYL SEALANT TAPE FLASH AJ 4 FASTENER 1 X 3 GUIDE FLASH AJ 3 26 OVERHEAD DOOR JAMBS PAGE 27 VERSION 2 GIRT FASTENERS PER FASTENER PATTERN SIDING PANEL 29 OVERHEAD DOOR JAMBS PAGE 27 VERSION 4 DOOR JAMB GIRT DOOR JAMB FASTENERS PER FASTENER PATTERN POST OVERHEAD DOOR POST OVERHEAD DOOR SIDING PANEL DOOR JAMB DOOR JAMB FASTENER 1 X 3 GUIDE FLASH PJFB BUTYL SEALANT TAPE FASTENER 1 X 3 GUIDE FLASH AJ 2 27 OVERHEAD DOOR JAMBS PAGE 27 38 Fabral com 30 OVERHEAD DOOR JAMBS PAGE 27

Page 41

POST FRAME TRIM DETAILS WALL GIRT SIDING PANEL POST BUTYL SEALANT TAPE FASTENER 2 X 2 FILLER BLOCK BUTYL SEALANT TAPE FASTENER OPTIONAL AL 3 TRIM AJ 4 JAMB TRIM BUTYL SEALANT TAPE FLASH AL 6 FLASH AJ 3 FASTENER SIDING PANEL SLIDING DOOR SLIDING DOOR JAMB 32 SLIDING DOOR JAMB DETAIL PAGE 28 SLIDING DOOR HEADER SLIDING DOOR BASE SIDING PANEL SIDING PANEL ON SLIDING DOOR FASTENERS PER FASTENER PATTERN FASTENERS PER FASTENER PATTERN FLASH AH 2 AH 3 AH 4 OR AH 5 DEPENDING ON PARTICULAR MANUFACTURER S DOOR TRACK BEING USED SLIDING DOOR GIRT OVERHEAD DOOR TRACK FLASH AD 1 FASTENERS PER FASTENER PATTERN TREATED BASE PLANK TRACK SUPPORT FLOOR 2 X 6 TRACK BOARD GRADE SLIDING DOOR GIRT SIDING PANEL ON SLIDING DOOR 33 SLIDING DOOR HEADER PAGE 29 View installation videos34 at SLIDING Fabral com videos 39 P DOOR BASE

Page 42

POST FRAME TRIM DETAILS WINDOW SILL WINDOW HEADER WINDOW UNIT SIDING PANEL 1 X 6 BEVELED FASTENERS PER FASTENER PATTERN BUTYL SEALANT TAPE FLASH AJ 3 2X4 2X4 INSIDE CLOSURE OPTIONAL AD1 DRIP CAP FASTENERS PER FASTENER PATTERN WINDOW UNIT SIDING PANEL 37 WINDOW HEADER PAGE 36 WINDOW SILL PAGE 30 WINDOW JAMB METAL SIDING OR TRANSLUCENT ROOF PANEL GIRT SIDING PANEL TRANSLUCENT PANEL 2 FASTENER EVERY MAIN RIB OR 12 O C MAX 2X4 FLASH AZ 2 FASTENER OPTIONAL BUTYL SEALANT TAPE FLASH AJ 3 WINDOW UNIT FASTENERS PER FASTENER PATTERN BUTYL SEALANT TAPE INSIDE CLOSURE OPTIONAL OUTSIDE CLOSURE OPTIONAL GIRT BUTYL SEALANT TAPE METAL SIDING OR TRANSLUCENT ROOF PANEL 8 WINDOW JAMB PAGE 30 35 40 Fabral com TRANSLUCENT ROOF PANEL PAGE

Page 43

POST FRAME TRIM DETAILS POST BUTYL SEALANT TAPE FASTENER 24 O C MAX GIRT FLASH AC 2 SIDING PANEL FASTENERS PER FASTENER PATTERN INSIDE CORNER VERSION 1 GIRT SIDING PANEL 21 INSIDE CORNER PAGE 25 FASTENERS PER FASTENER PATTERN BUTYL SEALANT TAPE POST VERSION 2 GIRT SIDING PANEL FASTENERS PER FASTENER PATTERN BUTYL SEALANT TAPE POST FASTENER 24 O C MAX FLASH AC 1 OR AC 4 19 OUTSIDE CORNER PAGE 24 OUTSIDE CORNERS FASTENER 24 O C MAX FLASH AC 1 OR AC 4 View installation videos at Fabral com videos 41

Page 44

RESIDENTIAL exposed fastener panel TRIM DETAILS All residential flashings are formed for a 4 12 pitch unless otherwise requested by the customer RESIDENTIAL VENTED EAVE UNDERLAYMENT INSIDE CLOSURE BUTYL SEALANT TAPE TOP BOTTOM OF CLOSURE FASTENER PER STANDARD EAVE PATTERN FABRAL ALUMINUM SOFFIT ROOF PANEL TOP PLATE FLASH CE 1 FASTENER 24 O C MAX F J TRIM SIDING PANEL FASTENER RESIDENTIAL EAVE 44 RES VENTED EAVE PAGE 35 ROOF STRUCTURE UNDERLAYMENT FLASH CE 1 FASTENER PER STANDARD EAVE PATTERN FASTENER 24 O C MAX 42 Fabral com BUTYL TAPE SEALANT ON TOP BOTTOM OF CLOSURE INSIDE CLOSURE

Page 45

RESIDENTIAL TRIM DETAILS RESIDENTIAL ENDWALL SIDING 2 FASTENER EVERY MAIN RIB FLASH ASW 1 BUTYL SEALANT TAPE TOP BOTTOM OF CLOSURE UNDERLAYMENT ROOF STRUCTURE ROOF PANEL OUTSIDE CLOSURE RESIDENTIAL SIDEWALL 47 RES ENDWALL PAGE 36 SIDING FLASH ASW 1 FIELD BEND AS REQUIRED 2 FASTENER 24 O C MAX BUTYL SEALANT TAPE ROOF PANEL ROOFING FELT AND ICE AND WATERSHIELD FOR ADDED WEATHER TIGHTNESS ROOFING STRUCTURE View installation videos at Fabral com videos 43

Page 46

RESIDENTIAL TRIM DETAILS RESIDENTIAL VALLEY SCREWS EACH SIDE OF MAIN RIB AND BETWEEN RIBS EAVE ENDLAPMINOR PATTERN CUT ROOF PANEL AS NECESSARY RV 2 SHOWN PEEL STICK SEALER STRIP 1 X 1 X 19 8 BLOCK CLOSURE FILL RIB VOIDS ROOF STRUCTURE SOLID 2X S OR PLYWOOD SOLID SUPPORT IS REQUIRED UNDER THE VALLEY PEEL STICK IS RECOMMENDED UNDER LAPPED ROOF PANELS AND VALLEY FLASHING LINING MUST CONTINUE DOWN TO EAVE LINE BUTYL SEALANT TOP BOTTOM OF SEALER STRIP 52 RES VALLEY PAGE 42 DORMER VALLEY RIDGE TRIM OUTSIDE CLOSURE TAPE SEALANT TOP BOTTOM ROOF PANEL LOWER VALLEY TRIM UNIVERSAL CLOSURE TAPE SEALANT TOP BOTTOM BUTYL TAPE SEALANT PEEL STICK UNDERLAYMENT UPPER VALLEY TRIM NOTE ROOF PANEL OMITTED ON OTHER SIDE OF RIDGE FOR CLARITY 44 Fabral com 39 DORMER VALLEYS PAGE 43

Page 47

RESIDENTIAL TRIM DETAILS RESIDENTIAL GAMBREL ROOF PANEL FASTENER PER STANDARD EAVE PATTERN BUTYL SEALANT TAPE TOP BOTTOM OF CLOSURE 2 FASTENER EVERY MAIN RIB UNDERLAYMENT INSIDE CLOSURE FLASH AT 2 OR AGR N4 GRANDRIB 3 OUTSIDE CLOSURE ROOF PANEL ROOF STRUCTURE BUTYL SEALANT TAPE TOP BOTTOM OF CLOSURE NOTE SPECIFY BOTH ROOF PITCHES WHEN ORDERING AT 2 FLASH AGRN 4 FOR GRANDRIB 3 AND AGRN 5 FOR STRONGRIB ARE FOR 3 12 TO 15 12 GAMBRELS 48 RES GAMBREL PAGE 37 RESIDENTIAL TRANSITION BUTYL SEALANT TAPE TOP BOTTOM OF CLOSURE FASTENER PER STANDARD EAVE PATTERN 2 FASTENER EVERY MAIN RIB INSIDE CLOSURE ROOF PANEL FLASH AT 1 ROOF STRUCTURE OUTSIDE CLOSURE BUTYL SEALANT TAPE TOP BOTTOM OF CLOSURE 50 RES TRANSITION PAGE 38 View installation videos at Fabral com videos 45

Page 48

RESIDENTIAL TRIM DETAILS RESIDENTIAL PIPE BOOTS VENTILATION PIPE OPTIONAL SILICONE SEALANT AROUND CUT OF BOOT PIPE BOOT BUTYL SEALANT TAPE UNDER BSE OF PIPE BOOT ROOF PANEL SCREWS SPACED 2 TO 3 MAX AROUND BASE TO SECURE ROOF STRUCTURE UNDERLAYMENT SKYLIGHT 51 RES PIPE BOOTS PAGE 38 SKYLIGHT SECTION A A and B B on following page 46 Fabral com 59 SKYLIGHT

Page 49

RESIDENTIAL TRIM DETAILS SKYLIGHT FLASH ASW 1 FIELD BEND AS REQUIRED FRAMING 2 FASTENER 6 O C MAX BUTYL SEALANT TAPE ROOF PANEL SKYLIGHT SECTION A A UNDERLAYMENT SECTION A A ROOF STRUCTURE SKYLIGHT 53 SKYLIGHT PAGE 40 SEALANT FLASHING REVERSE AL FLASHING CONTINUOUS SIKAFLEX CAULK PERIMETER 2 FASTENER 6 O C MAX BUTYL SEALANT TAPE UNDERLAYMENT SECTION A A ROOF STRUCTURE ROOF PANEL SKYLIGHT SECTION B B SECTION B B 54 SKYLIGHT PAGE 40 SKYLIGHT SEALANT 2 FASTENER EVERY MAIN RIB ASW 1 FLASHING FIELD MODIFIED TO FIT BUTYL SEALANT TAPE TOP BOTTOM OF CLOSURE FRAME ROOF PANEL OUTSIDE CLOSURE UNDERLAYMENT ROOF STRUCTURE 55 SKYLIGHT PAGE 40 View installation videos at Fabral com videos 47

Page 50

RESIDENTIAL TRIM DETAILS CHIMNEY DETAILS VERSION 1 BRICK 1 2 SAW CUT REGLET 1 DEEP BLOW OUT DUST FILL WITH SIKAFLEX SEALANT SET FLASH FASTEN WITH COMPATIBLE MASONRY ANCHOR FLASH ASW 1 FIELD MODIFY AS REQUIRED 2 FASTENER 24 O C MAX BUTYL SEALANT TAPE ROOF PANEL UNDERLAYMENT ROOF STRUCTURE BRICK CONTINUOUS SIKAFLEX CAULK PERIMETER 56 CHIMNEY PAGE VERSION 41 2 SAW CUT REGLET 21 1 DEEP BLOW OUT DUST FILL WITH SIKAFLEX SEALANT SET FLASH FASTEN WITH COMPATIBLE MASONRY ANCHOR FLASHING REVERSE AL FLASHING 2 FASTENER 24 O C MAX BUTYL SEALANT TAPE ROOF PANEL UNDERLAYMENT ROOF STRUCTURE 48 Fabral com

Page 51

RESIDENTIAL TRIM DETAILS CHIMNEY ENDWALL BRICK SAW CUT REGLET 21 1 DEEP BLOW OUT DUST FILL WITH SIKAFLEX SEALANT SET FLASH FASTEN WITH COMPATIBLE MASONRY ANCHOR 2 FASTENER EVERY MAIN RIB FLASH ASW 1 FIELD MODIFIED TO FIT BUTYL SEALANT TAPE TOP BOTTOM OF CLOSURE OUTSIDE CLOSURE ROOF PANEL UNDERLAYMENT ROOF STRUCTURE 58 CHIMNEY PAGE 41 RESIDENTIAL RIDGE HIP 2 FASTENER EVERY MAIN RIB RIDGE CAP RR 1 OR AR 3 ROOF PANEL BUTYL SEALANT TAPE TOP BOTTOM OF CLOSURE OUTSIDE CLOSURE ON HIP ROOFS USE 1 X 1 X 19 8 SEALER STRIP AND RR 1 FLASHING UNDERLAYMENT ROOF STRUCTURE 41 RES RIDGE HIP PAGE 34 View installation videos at Fabral com videos 49

Page 52

RESIDENTIAL TRIM DETAILS RESIDENTIAL VENTED RIDGE 2 FASTENER EVERY MAIN RIB RIDGE CAP RR 1 OR AR 3 ROOF PANEL CORRUGATED VENT BUTYL SEALANT TAPE TOP BOTTOM OF CLOSURE OUTSIDE CLOSURE ON HIP ROOFS USE 1 X 1 X 19 8 SEALER STRIP AND RR 1 FLASHING UNDERLAYMENT ROOF STRUCTURE 42 RES VENTED RIDGE PAGE 34 RESIDENTIAL GABLE ROOF PANEL FASTENER BUTYL TAPE RG 1 WG 1 OR AG 4 SCREW FASTENER 24 O C MAX ROOF STRUCTURE UNDERLAYMENT 50 Fabral com

Page 53

PAINT SYSTEMS WARRANTIES Enduracote is a paint system that takes performance to the next level Based on cutting edge resin technology this system offers unbeatable durability and superior long term performance against the elements The Enduracote PLUS Warranty Lifetime film integrity for walls roofs 30 year against fade chalk for walls and roofs 15 year edge rust against acid rain 25 year non perforation against acid rain for walls 20 years for roof The Enduracote Warranty for Galvalume Panels Lifetime film integrity for walls roofs 30 year against fade chalk for walls and roofs 20 year non perforation warranty For profiles Grandrib 3 1 1 2 SSR Climaguard Mighti Rib Horizon S Horizon 16 Ultra Loc Ultra Rib For profiles Grandrib 3 PLUS The Enduracote Warranty for Galvanized Panels Lifetime film integrity for walls roofs 30 year against fade chalk for walls and roofs 10 year edge rust against acid rain For profiles Grandrib 3 5V Crimp ProClad StrongClad Prime Rib Grandbeam OTHER WARRANTIES Polyester Paint Warranty 25 year limited film integrity 10 year against fade chalk For profiles Shelterguard 5 Rib Galvalume Perforation Warranty 20 year non perforation warranty for Grandrib 3 Mighti Rib Climaguard Horizon S and 1 1 2 SSR TrustiRib Warranty 40 year film integrity 30 year fade and chalk prorated at a subsequent 5 every year beginning at year 10 Galvalume is a registered trademark of BIEC International Aluminum Product Guarantee 30 year corrosion guarantee Product Warranties are available upon request The ENERGY STAR Program The ENERGY STAR Program promotes highly reflective roof systems that reflect solar energy These roof systems allow buildings to stay cooler and in turn use less electricity for air conditioning less electricity means a reduction in power generation and a reduction of pollutants discharged at power plants Fabral has attained ENERGY STAR approval for many of its Enduracote system colors Ask for Technical Bulletin 724 titled ENERGY STAR Approval for program details and a list of approved Enduracote colors All Fabral Enduracote Colors are ENERGY STAR Approved GALVALUME Please contact your Fabral representative for more information about Fabral warranties and paint systems 51

Page 54

COMPLETE CONTACT INFORMATION Contact by Phone Nationwide Plant Locations Cedar City UT Grapevine TX Gridley IL Marshfield WI 800 477 9066 Spokane WA 800 456 9124 800 477 8028 800 451 3974 Jackson GA Lancaster PA 800 432 2725 800 884 4484 800 477 2741 Contact by Email info fabral com Fabral com contact Live Tech Chat Fabral com Both numbers service Northern California Oregon Washington areas GENERAL NOTES 52 Fabral com 800 528 0878 St Joseph MN Tifton GA 800 873 3440 800 749 8144

Page 55

GENERAL NOTES 53

ACR METAL ROOFING & SIDING DISTRIBUTORS 

info@acrmetal.com

(717) 933-7044

4976 PA-419, Womelsdorf, PA 19567

Page 56

GRANDRIB 3 PLUS GRANDRIB TRUSTIRIB MIGHTI RIB PROCLAD HORIZON CLIMAGUARD FABRIB ENDURACOTE FABRAL FABRAL CORE are registered trademarks of Euramax International Inc UL is the trademark of UL LLC Galvalume is the trademark of BIEC International Inc Fabral 2015 All rights reserved Fabral com 98 32 007 1 15