Return to flip book view

Brochure_Blotter

Page 1

ATTO WesternBlotting systemWSE-4025ATTO Western BlottingSemi-Dry Blotting SystemWSE-4115Built-in Power Supply Unit (small size)PoweredBlot AceWSE-4045Semi Dry Blotting System for 2 mini gelsHorizeBLOT 2MSemi Dry Blotting System for 4 mini gelsHorizeBLOT 4MWSE-411555years with ElectrophoresisWSE-4125Built-in Power Supply UnitPoweredBLOT 2MWBQuick & QualityWestern BlottingWSE-4045WSE-4025WSE-4125NEWNEWNEW

Page 2

ATTO WesternBlotting systemWestern blotting is the basic experimental method to detect target component from a protein sample specifi cally and with high-sensitivity. There are 2 types of methods; "Semi-dry type" and "Wet type (Tank type)". ATTO recommend and provide Semi-dry type blotting system due to advantages below. And in 2019 ATTO accelerates to the new western blotting system as fast as 10min at minimum without preparation.Merit ① Save Amount of Blotting Solution・Wet type needs a large amount of blotting solution for immersing whole of filter papers, gels, membranes and electrodes, however Semi-dry type requires smaller amount of blotting solution just for immersing fi lter papers.Merit ② Simple Operation・Wet type needs setting a stack of fi lter papers, gels and membranes vertically after stacking them, causing misalignment, while Semi-dry type requires simply stacking them horizontally between electrodes.Merit ⑤ High Effi ciency with Optimized Solution・ATTO recommends AE-1460 EzBlot for Semi-dry blotting with 3 component solutions,and AE-1465 EzFastBlot for high speed blotting with single component solution.・Transfer effi ciency is improved by optimized blotting solution* when using semi-dry blotting system.     ※Kyhse-Andersen J et al., (1984) Electroblotting of multiple gels: a simple apparatus without buff er tank for rapid transfer of proteins from polyacrylamide        to nitrocellulose. J Biochem Biophys Methods.10:203-9.※ Blotting solution such as 25mM Tris, 192mM Glycine, 20% Methanol is not recommended in Semi-dry blotting. Transfer effi ciency is considerably deteriorated because this type solution is not optimaized for Semi-dry blotting.Merit ④ Short Operating TimeSemi-dry typeBlotting solutionWet typeBlotting solutionAE-1465 EzFastBlotstacking order陽極(+)陰極(-)EzFastBlot : Filter paper x2EzFastBlot : Filter paper x2EzFastBlot : GelEzFastBlot︓MembraneTris-Glycine-MeOH solution AE-1460 EzBlot・・The gel images above show AE-1460 EzBlot is more eff ective in Semi-dry blotting.What's semi-dry blotting?・Wet type needs a long time to prerare materials, equilibrate membranes, stack gels and membranes, and operate blotting devices, though Semi-dry type is completed in a short timeMerit ③ Lower Heat Generation・Heat generation of Semi-dry type is lower than Wet type due to smaller current required for blotting.Wet type generates higher heat genetration because of larger current required.Diff erence of tranfer effi ciency by blotting buff er in Semi-dry blotting01IntroductionAnd more - Fast BlottingMerit All features above are in your hands・Q Blot kit and PoweredBLOT, a blotter with built-in power supply off ers quick preparation and high speed transfer as long as 10 min.Easy and quick operation And high tranfer effi ciencyBest in 2019

Page 3

ATTO WesternBlotting systemProductNamePoweredBlot Ace PoweredBlot 2M HorizeBLOT 2M HorizeBLOT 4MCode No. 2322490 2322496 2322466 2322476Model WSE-4115 WSE-4125 WSE-4025 WSE-4045Power supply unitBuilt-inSTD (Standard mode): CV12V RAPID (Fast mode): CV24VTimer: 1-250min / Power consumption: 26WーElectrode size95mm(W) × 98mm(D) 205mm(W) × 100mm(D) 205mm(W) × 100mm(D) 205mm(W) × 200mm(D)Distance between electrodesMin︓03mmMax︓10mmMin︓03mmMax︓15mmMin︓03mmMax︓15mmPolarity   Upper : Cathode ( ー )   Lower : Anode (+)Blotting solution volume- 100mL100 - 200mL* Depending on the size and number of gels100 - 200mL* Depending on the size and number of gels100 - 400mL* Depending on the size and number of gelsGel Capacity   1 Compact Gel   1 Mini Gel   3 Compact Gels   2 Mini Gels   3 Compact Gels   2 Mini Gels   9 Compact Gels   4 Mini Gels   1 Slab GelBlotter Type Semi-dry blottimgMaterialsMain unit: AcrylicUpper: Corrosion-resistant stainless steelLower: Platinized titaniumPower supply case: ABS resinMain unit: AcrylicUpper: Corrosion-resistant stainless steelLower: Platinized titaniumPower supply case: MetalMain unit: AcrylicUpper: Corrosion-resistant stainless steelLower: Platinized titaniumDimensions(mm, except projection) Main unit: 170 (W) × 120 (D) × 107 (H) AC adaptor: 36(W) × 95 (D) × 31 (H) Main unit: 216 (W)×186 (D) × 114 (H) AC adoptor:  36(W) × 95 (D) × 31 (H)246(W) × 145 (D) × 92 (H) 246 (W) × 235 (D) × 92 (H)Weight0.77kg (except AC adaptor)2.1kg (except AC adaptor)1.8kg (except lead wires)3.0kg (except lead wires)Component・WSE-4115 Main unit : 1・AC adaptor : 1・Extention code : 1・Blotting roller : 1・Instruction manual : 1・WSE-4125 Main unit : 1・AC adaptor : 1・Extention code : 1・Blotting roller : 1・Instruction manual : 1・WSE-4025 Main unit : 1・Power lead wire with safety terminal * With reverse polarity prevention・Blotting roller : 1・Instruction manual : 1・WSE-4045 Main unit : 1・Power lead wire with safety terminal * With reverse polarity prevention・Blotting roller : 1・Instruction manual : 1Specifi cationsDirection to which sample movesGelMembraneSampleBefore blotting After blottingElectricity-+Compact Semi-dry Blotter with Built-in Power SupplySemi-dry Blotterfor 2 mini gelsSemi-dry Blotter for 4 mini gels02Specifi cationsCompact Size Semi-dry Blotting System with Built-in Power SupplyNEWNEWNEWNEWNEWNEWAnd more - Fast Blotting

Page 4

ATTO WesternBlotting systemWSE-4115 PoweredBlot AceCode No. Model Product Name2322490  WSE-4115  PoweredBlot Ace2322491  WSE-4115・C  PoweredBlot Ace (With Compact size P+ membrane & Filter Paper)2322492  WSE-4115・M  PoweredBlot Ace (With Mini size P+ membrane & Filter Paper)Simple opration: select mode and runSpace saving with built-in power supply■ "Standard mode" and "High speed mode" can be selected. ● STD (Standard) mode (Constant voltage 12V 【equivalent to constant current 2mA/cm2】)   → Blotting time : 30-60 min   → Timer : Selectable range is 1-250 min ● RAPID mode (Constant voltage 24V 【equivalent to constant current 7-8mA/cm2】)   → Blotting time : 10-30 min   → Timer : Selectable range is 1-250 min■ Required space fo setting the main unit: A5 size(148mm × 210mm)■Spring structure in the upper electrode unit off ers stable contact of the stack without unevenness of transfer.How to use① Remove the lid with a power supply unit from a device.② Remove the upper electrode, and stack fi lter papers, gels, and membrane on the lower electrode plate.③ Press the stack using an attached blotting roller to remove air bubbles.④ Select a blotting mode and press "RUN" button to start blotting.Component98mm95mmElectrode sizeExample of gel/membrane settingCompact gel x1Mini gel x1Blotter with Built-in Power Supply60mm60mmHigh-speed blotting with dedicated power supply83mm90mm03PoweredBlot Ace

Page 5

ATTO WesternBlotting systemWSE-4125 PoweredBlot 2MCode No. Model Product Name2322496  WSE-4125  PoweredBlot 2M2322497  WSE-4125・M  PoweredBlot 2M (With Mini size P+ membrane & Filter Paper)Simple opration: select mode and runSpace saving with built-in power supply■ "Standard mode" and "High speed mode" can be selected. ● STD (Standard) mode (Constant voltage 12V 【equivalent to constant current 2mA/cm2】)   → Blotting time : 30-60 min   → Timer : Selectable range is 1-250 min ● RAPID mode (Constant voltage 24V 【equivalent to constant current 7-8mA/cm2】)   → Blotting time : 10-30 min   → Timer : Selectable range is 1-250 min■Spring structure in the upper electrode unit off ers stable contact of the stack without unevenness of transfer.How to use① Remove the power unit and the upper electrode, and stack fi lter papers, gels, and membrane on the lower electrode plate.② Press the stack using an attached blotting roller to remove air bubbles.③ Place the upper electrode cover on the stack.④ Set the power unit and connect the AC adaptor.Blotter with Built-in Power Supply for 2 mini gelsHigh-speed blotting with dedicated power supply04PoweredBlot 2M100mm205mmElectrode sizeExample of gel/membrane settingCompact gel x2Mini gel x283mm90mmCompact gel x360mm60mm60mm60mm⑤ Select a blotting mode and press "RUN" button to start blotting.ComponentNew Product

Page 6

ATTO WesternBlotting system200mm205mmElectrode sizeExample of gel/membrane settingCompact gel x4 Max: x9Mini gel x4High-speed blotting enabledImproved operation and reproducibilityAlso supports large membranes and gelsSlab gel x1High-speed blotting enabled130mm138mm100mm205mmElectrode sizeExample of gel/membrane settingCompact gel x2Mini gel x283mm90mmCompact gel x360mm60mm60mm60mm60mm60mm83mm90mmWSE-4025 HorizeBLOT 2MSemi Dry Blotting System for 2 mini gelsWSE-4045 HorizeBLOT 4MSemi Dry Blotting System for 4 mini gels05HorizeBLOT 2M・4MReduce blotting unevennessReduce blotting unevennessRenewalRenewal

Page 7

ATTO WesternBlotting system■Spring structure in the upper electrode unit off ers stable contact of the stack without unevenness of transfer.■Just by setting it along the "alignment guide" of the main body, setting can be done easily■Firm fi xing the upper and lower electrode plates with a latch prevents deviation of the fi lter papers / membranes / gels■By adopting lead wire of reverse connection prevention structure, no accidental insertion of cathode and anode can occurHow to use③ Set the upper electrode plate along the alignment guide and fi x the notch.④ Set the lead wire, connect it to the power supply and start blottingData200kDa40kDaATTO W.B. System L Corporation W.B. SystemBlotting SolutionBlotting deviceTransfer timeAE-1465EzFastBlotHigh speed blottingkitHorizeBLOT 2M-RDedicated semi-dry blotterfor high speed blottingHigh speed blottingC.V. 25V, 7min.High speed blotting7min.ATTO Western Blotting System showed higher effi ciency in the high molcular weight region.RollerUnusedTipsRollerUsedContact unevenness caused by air bubblesCode No. Model Product Name2322466  WSE-4025  HorizeBLOT 2M2322467  WSE-4025・M  HorizeBLOT 2M (With Mini size P+ membrane & Filter Paper)2322476  WSE-4045  HorizeBLOT 4M2322477  WSE-4045・M  HorizeBLOT 4M (With Mini size P+ membrane & Filter Paper)● Air bubbles between fi lter papers, membranes and gels may cause nonuniformity of transfer.● Blotting roller can easily remove air bubbles.● ATTO blotting devices include a blotting roller as standard.200kDa40kDa06HorizeBLOT 2M・4MBlotting Roller2322479 - Blotting Roller2322462 -  Power lead wire for HorizeBLOT-ROptions/Consumables① Remove the power unit and the upper electrode, and stack fi lter papers, gels, and membrane on the lower electrode plate.② Press the stack using an attached blotting roller to remove air bubbles.Component● Since Q Blot kit is a pack of pad (substitute of fi lter papers) and membrane containing blotting solution, it can be used immediately after taking out from the bag. No more preparation needed.Q Blot kit Blot in 5min Min.

Page 8

ATTO WesternBlotting system07Related ProductsPVDF membranefor high effi ciency blotting□ Extremely low background□Already cut to the precast gel size● PVDF membrane with excellent protein binding capacity and retention.● Less prone to unevenness and can reduce the background compared with conventional products.Filter paper for blotting□Uniform, smooth, and clean sheets□Already cut to precast gel sizeWBWBCode No. Model Product Name Quantity2322450 WSE-4050P plusMembrane65mm × 65mm20 sheets/box2322451 WSE-405185mm × 90mm20 sheets/box2322452 WSE-4052130mm × 140mm10 sheets/box2322453 WSE-4053260mm × 3m1 roll/box● About 0.9 mm thickness to keep enough volume of blotting buff er● Ready to use: already cut to ATTO precast gel sizeCode No. Model Product Name Quantity2322437 CB-06AFilter paper65mm × 65mm0.9mm thick, 400 sheets/box2392393 CB-09A85mm × 90mm0.9mm thick, 400 sheets/box2322436 CB-13A130mm × 140mm0.9mm thick, 200 sheets/ 2 boxes2392493 CB-20A200mm × 200mm0.9mm thick, 100 sheets/boxATTO Western Blotting SystemRelated Products (Membrane, Filter Paper, Kit)Stack kit for quick blottingWB□Ready-to-use. You can start with it right out of the pack.□ High speed blotting within 5min at Min□ High transfer effi ciency●Q Blot kit is a pack of pad (substitute of fi lter papers) and PVDF membrane containing blotting solution. No more preparation needed. ●You can use immediately after taking out from the bag. ● High transfer effi ciency and uniformity● You can perform high speed blotting with Q Blot kit.Q Blot kitQuick & Quality !Pack of already equilibrated membrane stack24V 5minQ Blot kit24V 10minFastBlot 24V 10min* Fast blotting requires a high current power supply.The samples are diluted 1/2 in seriesCode No. Model Product Name Quantity2322445 WSE-4055Q Blot kitTop Stack : 10 packsBottom Stack : 10 packs Gel washing solution : 1 bottleYou can start blotting immediately after taking the kit out of the pack.New Product

Page 9

ATTO WesternBlotting systemBlotting Kit for LMW to HMW Protein Semi-dry Blotting□ Blotting solution optimized for Semi-dry blotting□ High transfer effi ciency● 3 component blotting solution for semi-dry blotting.● Just add small amount of methanol to prepare.● Low cost and versatile: you can use it with any blotting devices by other companies.Code No. Model Product Name Quantity2332600 AE-1460EzBlotA, C Solution︓500mL ×1B Solution︓500mL × 2WBATTO Western Blotting SystemRelated Products (Reagents)Wash buff er for western blottingWBWSE-7230□ Low cost and high performance□ Sterilized and DNase free□ Low viscosity Tween surfactant● WSE-7430 EzPBS(-) Phosphate buff ered saline Magnesium and potasium free Stelilized, DNase free● WSE-7230 EzTBS Tris hydrochloric acid buff ered saline Stelilized, DNase free● WSE-7235 EzTween 10%Tween ー 20 Low viscosity, easy to handle (weigh)Code No. Model Product Name Quantity2332380 WSE-7430EzPBS1000mL(10 × )2332625 WSE-7230EzTBS1000mL(10 × )2332623 WSE-7230L 5000mL(10 × )2332626 WSE-7235EzTween100mL(10% )Blocking ReagentsWB□ High blocking effi ciency□ Adjastable to your use case● High S/N can be achieved with these blocking reagents.● You can also apply them to southern/northern blot, ELISA.● Simply dilute the solution 5 times with distilled water to use.● Tween-20 is included in AE-1476 and AE-1477 (except AE-1475). It can be used as you prefer on your poupose.AE-1475AE-1476 AE-14773% skimmed milkAE-1475EzBlock ChemiAE-1476EzBlock BSAAE-1477EzBlock CASCode No. Model Product Name Quantity2332615 AE-1475EzBlock Chemi500mL (5 × )2332616 AE-1476EzBlock BSA200mL (5 × )2332617 AE-1477EzBlock CAS200mL (5 × )High Speed Blotting Solutionfor Semi-dry BlottingAE-1465□High speed blotting within 10min at Min□Transfer LMW to HMW widely□HMW type for larger molcule than 100kDa● Single component transfer buff er for fast bloting.● No methanol required. just dilute with distilled water prior to use● Low cost and versatile: you can use it with any blotting devices by other companies.Code No. Model Product Name Quantity2332590 AE-1465EzFastBlot500mL (10 ×)2332595 WSE-7210EzFastBlot HMW500mL (5 ×)60BlottingTime (min)40020EzFastBlotNormalTransfer Buff er10min60minWB左︓Tris-Glycine-Methanol 溶液右︓AE-1460 EzBlot使用AE-146008Related ProductsWSE-7210WSE-7235WSE-7430

Page 10

ATTO WesternBlotting systemATTO Western Blotting SystemRelated Products (Reagents)Luminol Substrate for HRP DetectionWB□Low cost and good performance□One component solution without preparation● Low price among competitors' equivalent substrates.● Ready-to-use: Single component, no need to further operation● Long time exposure (about 1 hour at maximum) ● Wide dynamic rangeCode No. Model Product Name Quantity2322438Pitatt clear100 sheetsWB□Just incubate for 15min at minimum□Can be used repeatedly with high S/N ratio● Shake and incubate for 15 min at room temp to strip antibodies● Less damage to antibody off ers high S/N detection repeatedly● Even rabbitmonochronal antibody with high titer can be removedLuminol Substrate for HRP DetectionWBWSE-7120S□Excellent cost performance□Highly sensitive and rapid detection● Excellent performance at low price● High sensitivity achieved in a short time/● Higher dilution ratio can be applied to antibody than conventional one.● Uniform light emission with a little amout of working solution ● Luminol reaction hardly saturated enables quantitative analysis of concentrated samples.Code No. Model Product Name Quantity2332637 WSE-7120SEzWestLumi plus50mL × 22332638 WSE-7120L 250mL × 2EzWestLumi plus Detected antibody︓HRP marked antihuman β -actinantibody (mouse), diluted in 1/10,000 timesDetection︓ Ez-Capture MG(Highly Sensitive Chemiluminescent Imager by ATTO)Stripping and Reprobing ReagentWBCompetitor's equivalent product ICompetitor's equivalent product PHighly Sensitive Colorimetric Substrate for HRP09 & Clear Pocket for Membrane SealSample : Human Transferrin       (2 fold dilution)1st antibody: Transferrin antibody2nd antibody: HRP standard sntibodyCapture: Ez-Capture ST25012562.531.2515.6pg/lane7.8Pitatt clearNEWWSE-7110□ Wrinkle-free transparent sheet● Protect the stained membrane and enables capture through it□8 times higher sensitivity than DAB □Single component, no need to prepare● TMB substrate for horseradish peroxidase (HRP) used for colorimetric detection of immunobloting (not applicable to ELISA)● Highly sensitive, reducing the usage of valuable antibodies.● Safer than DAB(diaminobenzidine). No organic solvent contained.EzWestBlue (30min react.)EzWestLumi plus (exposure 1min)Sample︓Hum Transferrin (2 fold dilution)1st antibody: Transferrin antibody (rabbit) × 1/10,000 dilut.2nd antibody: HRP marked anti-rabbit IgG antibody × 1/10,000 dilut.Colorimetric detection︓PC ScannerLuminesce︓Ez-Capture ST exposure 1min500025001250630315150pg/laneEzWestBlue (24 hours react.)Code No. Model Product Name Quantity2332630 AE-1490EzWest Blue200mL (1 × )2332629 AE-1490L 1L (1 × )Code No. Model Product Name Quantity2332530 WSE-7240EzReprobe500mL (1 × )Enhancer 3g2332531 WSE-7240L2L (1 × )Enhancer 12gAE-1490WSE-7120S1st detectionSmad22nd detectionGAPDH3rd detectionCoffi lin4th detectionβ -actinCode No. Model Product Name Quantity2332632 WSE-7110EzWestLumi One250mLRelated Products

Page 11

ATTO WesternBlotting system● WSE-3100 is recommended for high-current applications as semi- dry blotting as well as polyacrylamide gel electrophoresis.● Large LCD touch panel off ers quick & comfortable setteing/operation● Output: Constant Current/Constant Voltage/Constant Power ● You can use various preset conditions and also can set and save your original parameters as "Method" fi le. ● Power failure recovery, Safety and Graph Display functions, etc.Touch Panel Power Supplyfor Blotting and Electrophoresis□For both blotting and electrophoresis□High current output; Max3000mA Recomended for Semi-dry Fast BlottingCodeNo. Model Product Name2311130 WSE-3100PowerStation Ghible IWSE-3100Output specifi cations Voltage range (1V Step) 0 - 500V Current range (1mA Step) 0 - 3000mA Power range (1W Step) 0 - 200WPSATTO Western Blotting SystemRelated products (Power Supply/Gel Imaging System)High Current Power supply□High current output; Max3000mA□Recomended for Semi-dry Fast Blotting● WSE-3100 is recommended for high-current applications as semi- dry blotting.● Output: Constant Current/Constant Voltage/Constant Power ● More than 20 patterns of energizing conditions preset provided. You can set and record the conditions of each user.● It is easy to set parameters using a large dial.Code No. Model Product Name2311124 WSE-3500PowerStation HCWSE-3500Output specifi cations Voltage range (1V Step) 5 - 150V Current rng (10mA Step) 0 - 3000mA Power range (1W Step) 0 - 200WPSLow Noise and Cost, while High PerformanceChemiluminescence Imaging System□Chemiluminescence imaging of western blot□Clear image acquisition with low noise● 1.4 mega pixel, cooled CCD camera, F0.95 high sensitivity lens● Cooled CCD (-30℃ ), Subtraction processing using dark data, etc. off er high S/N, clear image data● Prestained M/W marker image and chemiluminescent image can be merged● Imaging software "CS Analzyer" for quantitative analysis● You can perform fl uorescent imaging and white light imaging with provided options.Model Product NameWSE-6100/6200seriesLuminoGraph Ⅰ、ⅡMIWSE-610010Highly Sensitive 6 Mega Pixel Cooled CCDChemiluminescence Imaging System□Chemiluminescence imaging of western blot□High resolution CCD and high sensitivity lens● 6 mega pixel, cooled CCD camera, F0.8 high sensitivity lens● 10 inch touch panel● Auto focus (motor controled) mounted● Flexible captire modes such as automatic exposure / cumulative capture / manual capture etc.● Prestained M/W marker image and chemiluminescent image can be merged● You can perform fl uorescent imaging and white light imaging with provided options.Model Product NameWSE-6300 seriesLuminoGraph ⅢWSE-6300MINEWRelated Products

Page 12

ATTO WesternBlotting system2019.1Semi-dry Blotting Devices Ver. 3Western Blotting DocumentsTips for Chemiluminescence Detection of Western BlottingATTO website provide further information about Western Blotting and Electrophoresis related products, including brochures, documents on experimental tips, movies, etc.https://www.atto.co.jp/eng/ATTO Corporation Providing research solutions for Biochemistry/Molecular Biology/Getnetic Engineering Head Offi ce: 3-2-2 Motoasakusa, Taito-ku, Tokyo, 111-0041 JapanTEL: 81-3-5827-4863/FAX: 81-3-5827-6647/E-Mail: eig@atto.co.jp