Return to flip book view

ALEXTRONIXCatalog Vol 4 update 1

Page 1

Alex-Tronix Agricultural and Industrial Controls Website: alextronix.com Phone: (559) 276-2888 Fax: (559) 276-2890 Toll Free: (888) 224-7630 The Leader in Filter Backwash Controllers Since 1977 Product Catalog Vol. 4

Page 2

FMPD Product Overview • New and improved replacement for previous SPD model sensors • Digital read works with any Alex-Tronix Filter Master 4-32 station controller • Included clamp mounts FMPD on your 3/4” pipe or wall • Made of durable high grade stainless steel • 0-30 lbs pressure differential measurement for reliable accuracy *pipe not included, will not work with FM2 model THE NEW FMPD FILTER MASTER PRESSURE DIFFERENTIAL SENSOR

Page 3

Our Most Advanced Line of Filter Backwash Controllers Featuring: • 1-32 stations • Modbus communications ready in all FM4/8 and UL models • New FMPD 1-30 psi digital pressure differential sensor with greater reliability and all stainless steel construction • Outdoor NEMA 4X enclosure with FM4/8, and UL listing available • One-second timing increments • Selectable progressive or sequential stations in all FM4-32 models • Solar panel option *Filter Master Series Controller Selection Chart in Back THE FILTER MASTER SERIES FM-2DCL FM-4P FM-4/8 FM-12/16/32 FMPD FM-4/8UL

Page 4

FM-2DCL Product Overview • One Station Plus Master Valve or 2 Stations • Input: 4 AA Batteries • 12 VDC 2-Wire Latching Solenoids • 10,000 Cycles or 1 season with Lithium AA Batteries Provided • Backwash Time Range 1-255 seconds • Periodic Flush Interval Programmable in Days, Hours, and Minutes • PD Delay-Adjustable • Resettable Backwash Count • Actuation Method: Periodic, Manual, or PD • One-Second Timing Increments • Optional Murphy Pressure Differential Gauge (PDMU) • 2-Year Warranty on Controller 1-2 Stations Battery Operated Outdoor Enclosure Alex-Tronix The Leader in Filter Backwash Controls

Page 5

FM-2 DCL Features and Options STANDARD FEATURES NUMBER OF STATIONS PLUS MASTER VALVE 1 Plus Master Valve or 2 Valves INPUT VOLTAGE 4 AA Lithium Baeries STATION OPERATION Sequenal PD DELAY Adjustable OUTPUT 12 VDC 2-Wire Latching Solenoids RESETTABLE BACKWASH COUNT ✓ ENCLOSURE TYPE Outdoor Plasc Case ACTUATION METHOD PERIODIC, MANUAL, OR PD ✓ SIMPLE PROGRAMMING ✓ 2 YEAR WARRANTY ✓ OPTIONS PDMU 1-15 PSI MURPHY PD GAUGE Oponal PDBRKT MOUNTING BRACKET FOR PDMU Oponal DIMENSIONS HEIGHT (in) 9.75 WIDTH (in) 8.0 DEPTH (in) 4.0 SHIPPING WEIGHT (lb) 5.0

Page 6

Alex-Tronix FM-4P Product Overview • 4 Stations Plus Master Valve • New FMPD Stainless Steel Pressure Differential Sensor with greater reliability and all stainless steel construction • Input: 115 or Optional 230 VAC 50/60 Hz, or 12-15 VDC • 24 VAC, 12 VDC, or 12 VDC 2-Wire Latching Solenoids • Progressive or Sequential Station Operation • Backwash Time Range 1-255 seconds • Periodic Flush Interval Programmable in Days, Hours, and Minutes • PD Delay-Adjustable • Resettable Backwash Count • Actuation Method: Periodic, Manual, or PD • One-Second Timing Increments • Heavy Duty Transformer Option • Solar Panel Option • 2-Year Warranty The Leader in Filter Backwash Controls 4 Stations Plus Master Valve Outdoor Enclosure Backlit Display Visible Through Window

Page 7

FM-4P Features and Options STANDARD FEATURES NUMBER OF STATIONS PLUS MASTER VALVE 4 INPUT VOLTAGE 115 VAC 50/60 Hz, or 12-15 VDC OUTPUTS 24 VAC, 12 VDC, or 12 VDC 2-Wire Latching Solenoids SELECTABLE STATION OPERATION PROGRESSIVE OR SEQUENTIAL ✓ FMPD INCLUDED ✓ PD DELAY Adjustable FRONT PANEL Screw-In Panel RESETTABLE BACKWASH COUNT ✓ ENCLOSURE TYPE Outdoor Plasc Case ACTUATION METHOD PERIODIC, MANUAL, OR PD ✓ SIMPLE PROGRAMMING ✓ 2 YEAR WARRANTY ✓ OPTIONS SP5 SOLAR PANEL WITH REGULATOR AND MOUNTING BRACKET FOR SP5 Oponal BATT-7 7 AMP-HOUR BATTERY FOR DCL MODELS Oponal T-230 230 VAC TRANSFORMER Oponal T-115HD 115 VAC HEAVY DUTY TRANSFORMER Oponal T-230HD 230 VAC HEAVY DUTY TRANSFORMER Oponal DIMENSIONS HEIGHT (in) 9.75 WIDTH (in) 8.0 DEPTH (in) 4.0 SHIPPING WEIGHT (lb) 7.0

Page 8

Alex-Tronix FM-4/8 Product Overview • 4 or 8 Stations Plus Master Valve • New FMPD 1-30 psi digital pressure differential sensor with greater reliability and all stainless steel construction • Modbus Communications Ready with RS485 Port Included • Input: 115 or Optional 230 VAC 50/60 Hz, or 12-15 VDC • 24 VAC, 12 VDC, or 12 VDC 2-Wire Latching Solenoids • Progressive or Sequential Station Operation • PD Delay-Adjustable • Backwash Time Range 1 Second to 92 Minutes and 59 Seconds • Periodic Flush Interval Programmable in Days, Hours, and Minutes • Resettable Backwash Count • Actuation Method: Periodic, Manual, or PD • One-Second Timing Increments • Heavy Duty Transformer Option • Solar Panel Option • PD Alarm • 2-Year Warranty The Leader in Filter Backwash Controls 4 or 8 Stations Plus Master Meets NEMA 4X Rating New FMPD installed on 3/4” pipe

Page 9

FM-4/8 Features and Options STANDARD FEATURES FM-4/8 NUMBER OF STATIONS PLUS MAS-TER VALVE 4 or 8 INPUT VOLTAGE 115 VAC 50/60 Hz, or 12-15 VDC OUTPUTS 24 VAC, 12 VDC, or 12 VDC 2-Wire Latching Solenoids SELECTABLE STATION OPERATION SEQUENTIAL OR PROGRESSIVE ✓ COMMUNICATIONS MODBUS READY ✓ FMPD INCLUDED ✓ PD DELAY Adjustable SWING OUT, PLUG IN FRONT PANEL ✓ RESETTABLE BACKWASH COUNT ✓ ALARM FEATURE ✓ ENCLOSURE TYPE RUGGED OUTDOOR MEETS NEMA 4X Rang ACTUATION METHOD PERIODIC, MANUAL, OR PD ✓ SIMPLE PROGRAMMING ✓ 2 YEAR WARRANTY ✓ OPTIONS SP5 SOLAR PANEL WITH VOLT REG AND MOUNTING BRACKET Oponal BATT-7 7 AMP-HOUR BATTERY FOR DCL MODELS Oponal T-230 230 VAC TRANSFORMER Oponal T-115HD 115 VAC HEAVY DUTY TRANSFORMER Oponal T-230HD 230 VAC HEAVY DUTY TRANSFORMER Oponal DIMENSIONS HEIGHT (in) 12.0 WIDTH (in) 10.0 DEPTH (in) 5.5 SHIPPING WEIGHT (lb) 9.0

Page 10

Alex-Tronix FM 4/8UL Product Overview • 4 or 8 Stations Plus Master Valve • New FMPD 1-30 psi digital pressure differential sensor with greater reliability and all stainless steel construction • Modbus Communications Ready with RS485 Included • UL Listed in NEMA 4X Rated Enclosure • Input: 115 or Optional 230 VAC 50/60 Hz • 24 VAC, 12 VDC, or 12 VDC 2-Wire Latching Solenoids • Progressive or Sequential Station Operation • PD Delay-Adjustable • Backwash Time Range 1 Second to 92 Minutes and 59 Seconds • Periodic Flush Interval Programmable in Days, Hours, and Minutes • Resettable Backwash Count • Actuation Method: Periodic, Manual, or PD • One-Second Timing Increments • PD Alarm • 2-Year Warranty The Leader in Filter Backwash Controls 4 or 8 Stations Plus Master Valve UL Listed

Page 11

FM-4/8 UL Features and Options STANDARD FEATURES FM-4/8 UL NUMBER OF STATIONS PLUS MASTER VALVE 4 OR 8 INPUT VOLTAGE 115 VAC 50/60 Hz OUTPUTS 24 VAC, 12 VDC, or 12 VDC 2–Wire Latching Solenoids SELECTABLE STATION OPERATION PROGRESSIVE OR SEQUENTIAL ✓ COMMUNICATIONS MODBUS READY ✓ FMPD INCLUDED ✓ PD DELAY Adjustable SWING OUT, PLUG IN FRONT PANEL ✓ RESETTABLE BACKWASH COUNT ✓ ALARM FEATURE ✓ ENCLOSURE TYPE RUGGED OUTDOOR TYPE IP 66 DUST TIGHT, PROTECTS AGAINST JETS OF WATER Designed to Meet NEMA 4X Rang ACTUATION METHOD PERIODIC, MANUAL, OR PD ✓ SIMPLE PROGRAMMING ✓ 2 YEAR WARRANTY ✓ OPTIONS T-230 230 VAC TRANSFORMER Oponal DIMENSIONS HEIGHT (in) 12 WIDTH (in) 10 DEPTH (in) 5.5 SHIPPING WEIGHT (lb) 9.0

Page 12

Alex-Tronix FM-12/16/32 Product Overview • 12,16 or 32 Stations Plus Master Valve • New FMPD 1-30 psi digital pressure differential sensor with greater reliability and all stainless steel construction • Input: 115 or Optional 230 VAC 50/60 Hz, or 12-15 VDC • Outputs: 24 VAC, 12 VDC, or 12 VDC 2-Wire Latching Solenoids • Progressive or Sequential Station Operation • PD Delay-Adjustable • Backwash Time Range 1 Second to 92 Minutes and 59 Seconds • Periodic Flush Interval Programmable in Days, Hours, and Minutes • Resettable Backwash Count • Actuation Type: Periodic, Manual, or PD • One-Second Timing Increments • Heavy Duty Transformer Option • Solar Panel Option • PD Alarm • 2-Year Warranty The Leader in Filter Backwash Controls 12, 16 or 32 Stations Plus Master Valve FM-12/16 Easy Plug-in Retrofit from existing F12/16 AC/DC/DCL Powder Coated Steel Enclosure

Page 13

FM-12/16/32 Features and Options STANDARD FEATURES FM-12/16/32 NUMBER OF STATIONS PLUS MASTER VALVE 12, 16, or 32 Staons INPUT VOLTAGE 115 VAC 50/60 Hz, or 12-15 VDC OUTPUTS 24 VAC, 12 VDC, Or 12 VDC 2-Wire Latching Solenoids SELECTABLE STATION OPERATION PROGRESSIVE ✓ SEQUENTIAL ✓ FMPD INCLUDED ✓ PD DELAY ✓ SWING OUT, PLUG IN FRONT PANEL ✓ RESETTABLE BACKWASH COUNT ✓ ALARM FEATURE ✓ ENCLOSURE TYPE Powder-Coated Steel ACTUATION METHOD PERIODIC, MANUAL, OR PD ✓ SIMPLE PROGRAMMING ✓ 2 YEAR WARRANTY ✓ EASY PANEL SWAP WITH F-SERIES FM-12/16 from F12/16 OPTIONS SP5 SOLAR PANEL WITH VOLT REG AND MOUNTING BRACKET Oponal BATT-7 7 AMP-HOUR BATTERY FOR DCL MODELS Oponal T-230 230 VAC TRANSFORMER Oponal T-115HD 115 VAC HEAVY DUTY TRANSFORMER Oponal T-230HD 230 VAC HEAVY DUTY TRANSFORMER Oponal DIMENSIONS HEIGHT (in) 9.5 WIDTH (in) 13.0 DEPTH (in) 5.25 SHIPPING WEIGHT (lb) 12.0

Page 14

Alex-Tronix Grey-Rain Product Overview The Grey-Rain Controller is designed to allow flexible control of otherwise manually flushed sand media, disc, or screen filter systems common to the rainwater harvest and reclaimed water irrigation systems. It can flush based on differential pressure, accumulated time, or a combination of both Power input 12 to 24 volt AC or DC 120 or 240 VAC with optional transformer or power supply. Valve Output voltage is the same as controller input Grey-Rain can drive 3 wire Motorized, Solenoid, Direct Acting, or any combination of these valves. 3 AMP limited by user replaceable fuse (ATO type) All outputs have NO/NC contacts with front panel status indicator lights 2 Filter Outputs (Selectable) 1 Master Output 1 Accessory output Pressure Differential inputs for optional PD Switch (Murphy) or FMPD Solid state sensor The Leader in Filter Backwash Controls Rain/Reclaimed Water Backwash Controller Operates motorized valves, solenoids, or direct acting valves 12-24 VAC or DC Solenoids 120 VAC or Optional 240 VAC input

Page 15

The Grey-Rain Controller is designed to allow flexible control of otherwise manually flushed sand media, disc, or screen filter systems common to the rainwater harvest and reclaimed water irrigation systems. It can flush based on differential pressure, accumulated time, or a combination of both Power input 12 to 24 volt AC or DC 120 or 240 VAC with optional transformer or power supply. Valve Output voltage is the same as controller input Grey-Rain can drive 3 wire Motorized, Solenoid, Direct Acting, or any combination of these valves. 3 AMP limited by user replaceable fuse (ATO type) All outputs have NO/NC contacts with front panel status indicator lights 2 Filter Outputs (Selectable) 1 Master Output 1 Accessory output Pressure Differential inputs for optional PD Switch (Murphy) or FMPD Solid state sensor Programming Pre-dwell time 0 to 255 seconds Backwash time in minutes and seconds to 100 minutes maximum Dwell time 0 to 99 seconds Post Dwell time 0 to 255 seconds PD Delay time 0 to 255 seconds Periodic flush adjustable in days hours and minutes to 99 days maximum Resettable Backwash count Illuminated Display Rain and Sun resistant Outdoor Plastic Enclosure 2 year warranty Height 9.75” width 8.0” depth 4.0” weight 3 pounds Grey-Rain Features and Options

Page 16

Page 17

Our classic designed filter backwash controllers that set the standard for quality and reliability THE F-SERIES F2-AC/DC-D F3-AC/DC/DCL F4/8-AC/DC/DCL F12/16-AC/DC/DCL *F-Series Controller Selection Chart in Back

Page 18

Alex-Tronix F2AC/DC-D Product Overview • 2 Stations Plus Master Valve • Input: 115 or Optional 230 VAC 50/60 Hz, or 12-15 VDC • Outputs: 24 VAC, or 12 VDC Non-Latching Solenoids • Sequential Station Operation • PD Delay-Fixed • Resettable Backwash Count • Actuation Method: Periodic, Manual, or PD • Solar Panel Option • Murphy PD Gauge Included • PD Alarm • 2-Year Warranty The Leader in Filter Backwash Controls 2 Stations Plus Master Valve Rust-Proof Outdoor Enclosure Display Visible through Window

Page 19

F2 AC/DC-D Features and Options STANDARD FEATURES F2 AC/DC-D NUMBER OF STATIONS PLUS MASTER VALVE 2 INPUT VOLTAGE 115 VAC 50/60 Hz, or 12-15 VDC OUTPUTS 24 VAC or 12 VDC Non-Latching Solenoids PDMU INCLUDED 1-15 PSI MURPHY PD GAUGE W/BRKT ✓ PD DELAY Fixed RESETTABLE BACKWASH COUNT ✓ ALARM ✓ ENCLOSURE TYPE Outdoor Plasc ACTUATION METHOD PERIODIC, MANUAL OR PD ✓ SIMPLE PROGRAMMING ✓ 2 YEAR WARRANTY ✓ OPTIONS T-230 230 VAC TRANSFORMER Oponal T-115HD HEAVY DUTY 115VAC TRANSFORMER Oponal T-230HD HEAVY DUTY 230VAC TRANSFORMER Oponal DIMENSIONS HEIGHT (in) 9.75 WIDTH (in) 8.0 DEPTH (in) 4.0 SHIPPING WEIGHT (lb) 5.0

Page 20

Alex-Tronix F3AC/DC/DCL Product Overview • 3 Stations Plus Master Valve • Input: 115 or Optional 230 VAC 50/60 Hz, or 12-15 VDC • Outputs: 24 VAC, 12 VDC, or 12 VDC 2-Wire Latching Solenoids • Sequential Station Operation • PD Delay-Fixed • Resettable Backwash Count • Actuation Method: Periodic, Manual, or PD • Solar Panel Option • Murphy PD Gauge Included • 2-Year Warranty The Leader in Filter Backwash Controls 3 Stations Plus Master Valve Powder Coated Steel Enclosure

Page 21

F3 AC/DC/DCL Features and Options STANDARD FEATURES F3 AC/DC/DCL NUMBER OF STATIONS PLUS MASTER VALVE 3 INPUT VOLTAGE 115 VAC 50/60 Hz, or 12-15 VDC OUTPUTS 24 VAC, 12 VDC, or 12 VDC 2-Wire Latching Solenoids PDMU INCLUDED 1-15 PSI MURPHY PD GAUGE ✓ PD DELAY Fixed SWING OUT,PLUG IN FRONT PANEL ✓ RESETTABLE BACKWASH COUNT ✓ ENCLOSURE TYPE Powder-Coated Steel ACTUATION METHOD PERIODIC, MANUAL OR PD ✓ SIMPLE PROGRAMMING ✓ 2 YEAR WARRANTY ✓ OPTIONS SP5 5 WATT SOLAR PANEL W/VOLT REG AND MOUNTING BRACKET Oponal BATT-7 7 AMP-HOUR BATTERY FOR DCL MODELS Oponal T-230 230 VAC TRANSFORMER Oponal T-115HD HEAVY DUTY 115 VAC TRANSFORMER Oponal T-230HD HEAVY DUTY 230 VAC TRANSFORMER Oponal PDBRKT MOUNTING BRACKET FOR PDMU Oponal DIMENSIONS HEIGHT (in) 8.25 WIDTH (in) 7.5 DEPTH (in) 5.0 SHIPPING WEIGHT (lb) 9.0

Page 22

Alex-Tronix F4/8 AC/DC/DCL Product Overview • 4 or 8 Stations Plus Master Valve • Input: 115 or Optional 230 VAC 50/60 Hz, or 12-15 VDC • Outputs: 24 VAC, 12 VDC, or 12 VDC 2-Wire Latching Solenoids • Sequential Station Operation • PD Delay-Adjustable • Resettable Backwash Count • Actuation Method: Periodic, Manual, or PD • Solar Panel Option • Murphy PD Gauge Included • PD Alarm • 2-Year Warranty The Leader in Filter Backwash Controls 4 or 8 Stations Plus Master Valve Powder Coated Steel Enclosure

Page 23

F4/8 AC/DC/DCL Features and Options STANDARD FEATURES F4/8 AC/DC/DCL NUMBER OF STATIONS PLUS MASTER VALVE 4 or 8 INPUT VOLTAGE 115 VAC 50/60 Hz, or 12-15 VDC OUTPUTS 24 VAC, 12 VDC, or 12 VDC 2-Wire Latching Solenoids PDMU INCLUDED 1-15 PSI MURPHY PD GAUGE ✓ PD DELAY Adjustable SWING OUT,PLUG IN FRONT PANEL ✓ RESETTABLE BACKWASH COUNT ✓ ALARM ✓ ENCLOSURE TYPE Powder-Coated Steel ACTUATION METHOD PERIODIC, MANUAL OR PD ✓ SIMPLE PROGRAMMING ✓ 2 YEAR WARRANTY ✓ OPTIONS SP5 5 WATT SOLAR PANEL W/VOLT REG AND MOUNTING BRACKET Oponal BATT-7 7 AMP-HR BATTERY FOR DCL MODELS Oponal T-230 230 VAC TRANSFORMER Oponal T-115HD HEAVY DUTY 115 VAC TRANSFORMER Oponal T-230HD HEAVY DUTY 230 VAC TRANSFORMER Oponal PDBRKT MOUNTING BRACKET FOR PDMU Oponal DIMENSIONS HEIGHT (in) 8.25 WIDTH (in) 7.5 DEPTH (in) 5.0 SHIPPING WEIGHT (lb) 9.0

Page 24

Alex-Tronix F12/16 AC/DC/DCL Product Overview • 12 or 16 Stations Plus Master Valve • Input: 115 or Optional 230 VAC 50/60 Hz, or 12-15 VDC • Outputs: 24 VAC, 12 VDC, or 12 VDC 2-Wire Latching Solenoids • Sequential Station Operation • PD Delay-Adjustable • Resettable Backwash Count • Actuation Method: Periodic, Manual, or PD • Solar Panel Option • Murphy PD Gauge Included • PD Alarm • 2-Year Warranty The Leader in Filter Backwash Controls 12 or 16 Stations Plus Master Valve Powder Coated Steel Enclosure

Page 25

F12/16 AC/DC/DCL Features and Options STANDARD FEATURES F12/16 AC/DC/DCL NUMBER OF STATIONS PLUS MASTER VALVE 12 or 16 INPUT VOLTAGE 115 VAC 50/60 Hz , or 12-15 VDC OUTPUTS 24 VAC, 12 VDC, or 12 VDC 2-Wire Latching Solenoids PDMU INCLUDED 1-15 PSI MURPHY PD GAUGE ✓ PD DELAY Adjustable SWING OUT,PLUG IN FRONT PANEL ✓ RESETTABLE BACKWASH COUNT ✓ ALARM ✓ ENCLOSURE TYPE Powder-Coated Steel ACTUATION METHOD PERIODIC, MANUAL OR PD ✓ SIMPLE PROGRAMMING ✓ 2 YEAR WARRANTY ✓ OPTIONS SP5 5 WATT SOLAR PANEL W/VOLT REG AND MOUNTING BRACKET Oponal BATT-7 7 AMP-HR BATTERY FOR DCL MODELS Oponal T-230 230 VAC TRANSFORMER Oponal T-115HD HEAVY DUTY 115 VAC TRANSFORMER Oponal T-230HD HEAVY DUTY 230 VAC TRANSFORMER Oponal PDBRKT MOUNTING BRACKET FOR PDMU Oponal DIMENSIONS HEIGHT (in) 9.5 WIDTH (in) 13.0 DEPTH (in) 5.25 SHIPPING WEIGHT (lb) 14.0

Page 26

Alex-Tronix UNIVERSAL MOUNTING BRACKET Product Overview • Solves all mounting issues with one bracket • Universally mounts all Alex-Tronix filter backwash controller models • Includes mounting bracket and rings designed to attach using user-supplied 3/4” pipe (nominal pipe O.D. 1.050 in) • Mounts Alex-Tronix FMPD (Pressure Differential Sensor) • Made of aluminum The Leader in Filter Backwash Controls *pipe not included Pressure Differential Sensor (FMPD) Mounts under Bracket Front Back

Page 27

FILTER MASTER SERIES CONTROLLER SELECTION CHART STD FEATURES FM-2DCL FM-4P FM-4/8 FM-4/8UL FM-12/16/32 STATIONS PLUS MASTER VALVE 1 Plus Master Valve or 2 4 4 or 8 4 or 8 12, 16, or 32 INPUT VOLTAGE 4 AA Baeries 115 VAC 50/60 Hz 115 VAC 50/60 Hz 115 VAC 50/60 Hz 115 VAC 50/60 Hz OUTPUT SELECTABLE TO OPERATE 24 VAC, 12 VDC, OR 12 VDC 2-WIRE LATCHING SOLENOIDS 12 VDC 2-Wire Latching Solenoids Only ✓ ✓ ✓ ✓ SELECTABLE STATION OPERATION Progressive or Sequenal Progressive or Sequenal Progressive or Sequenal Progressive or Sequenal Progressive or Sequenal COMMUNICATIONS MODBUS READY ✓ ✓ PD INCLUDED ✓ ✓ ✓ ✓ PD DELAY Adjustable Adjustable Adjustable Adjustable Adjustable SWING OUT, PLUG IN FRONT PANEL Screw-In Panel Screw-In Panel ✓ ✓ ✓ RESETTABLE BACKWASH COUNT ✓ ✓ ✓ ✓ ✓ ALARM FEATURE ✓ ✓ ✓ ENCLOSURE TYPE Rust-Proof Outdoor Rust-Proof Outdoor Meets NEMA 4X Rang Meets NEMA 4X Rang Powder-Coated Steel ACTUATION METHOD PERIODIC, MANUAL, OR PD ✓ ✓ ✓ ✓ ✓ SIMPLE PROGRAMMING ✓ ✓ ✓ ✓ ✓ 2 YEAR WARRANTY ✓ ✓ ✓ ✓ ✓ UL LISTED ✓ EASY RETROFIT FROM F-SERIES F12/16 OPTIONS FMPD 1-30 PSI FILTER MASTER PD SENSOR Included Included Included Included SP5 5 WATT SOLAR PANEL W/ VOLT REG AND MOUNTING BRACKET Oponal Oponal Oponal Oponal PDMU 1-15 PSI MURPHY PD GAUGE Oponal Oponal Oponal Oponal Oponal PDBRKT MOUNTING BRACKET FOR PDMU Oponal Oponal Oponal Oponal Oponal BATT-7 7 AMP-HOUR BATTERY PACK FOR DCL MODELS Oponal Oponal Oponal Oponal T-115 115 VAC TRANSFORMER Included Included Included Included T-230 230 VAC TRANSFORMER Oponal Oponal Oponal Oponal T-115HD 115 VAC HEAVY DUTY TRANSFORMER Oponal Oponal Oponal Oponal T-230HD 230 VAC HEAVY DUTY TRANSFORMER Oponal Oponal Oponal Oponal

Page 28

F-SERIES CONTROLLER SELECTION CHART STANDARD FEATURES F2 AC/DC-D F3 AC/DC/DCL F4/8 AC/DC/DCL F12/16 AC/DC/DCL NUMBER OF STATIONS PLUS MASTER VALVE 2 3 4 or 8 12 or 16 INPUT VOLTAGE 115 VAC 50/60 Hz , or 12-15 VDC 115 VAC 50/60 Hz , or 12-15 VDC 115 VAC 50/60 Hz , or 12-15 VDC 115 VAC 50/60 Hz , or 12-15 VDC OUTPUTS 24 VAC or 12 VDC Non-Latching Solenoids 24 VAC, 12 VDC, or 12 VDC 2-Wire Latching Solenoids 24 VAC, 12 VDC, or 12 VDC 2-Wire Latching Solenoids 24 VAC, 12 VDC, or 12 VDC 2-Wire Latching Solenoids PDMU INCLUDED 1-15 PSI MURPHY PD GAUGE ✓ ✓ ✓ ✓ PD DELAY Fixed Fixed Adjustable Adjustable SWING OUT,PLUG IN FRONT PANEL Screw-In ✓ ✓ ✓ RESETTABLE BACKWASH COUNT ✓ ✓ ✓ ✓ ALARM ✓ ✓ ✓ ENCLOSURE TYPE Rust-Proof Outdoor Powder-Coated Steel Powder-Coated Steel Powder-Coated Steel ACTUATION METHOD PERIODIC, MANUAL OR PD ✓ ✓ ✓ ✓ SIMPLE PROGRAMMING ✓ ✓ ✓ ✓ 2 YEAR WARRANTY ✓ ✓ ✓ ✓ OPTIONS SP5 5 WATT SOLAR PANEL W/ VOLT REG AND MOUNTING BRACKET N/A Oponal Oponal Oponal BATT-7 7 AMP-HR BATTERY PACK FOR DCL MODELS N/A Oponal Oponal Oponal T-230 230 VAC TRANSFORMER Oponal Oponal Oponal Oponal T-115HD HEAVY DUTY 115 VAC TRANSFORMER Oponal Oponal Oponal Oponal T-230HD HEAVY DUTY 230 VAC TRANSFORMER Oponal Oponal Oponal Oponal PDBRKT MOUNTING BRACKET FOR PDMU Standard Oponal Oponal Oponal

Page 29

THE BEST SERVICE IN THE INDUSTRY • Live technical support • Loaner panel program available • In most cases, repair turnaround me within 48 hrs when accompanied with PO from an authorized dealer

Page 30

In 1977, Alex-Tronix opened its doors for the farmers of the Central San Joaquin Valley with a mission to save water and energy. We were the first manufacturer to reliably automate agricultural filter backwash systems. Today, OEM (Original Equipment Manufacturers) and dealers sell our controls in every region of the world, so you can find our high quality products wherever you need them. Made in America, we pride ourselves on manufacturing simple to program, reliable controls for your agricultural, industrial, or commercial water filtration needs. With the best service in the industry, Alex-Tronix has set the standard for filter backwash automation, innovation, and customer satisfaction in the world today. About Alex-Tronix Website: alextronix.com Phone: (559) 276-2888 Fax: (559) 276-2890 Toll Free: (888) 224-7630