—POWER PANELBOARDS AND SWITCHBOARDSTmax® XT retrofit kits for Spectra™ panelboardsExtending the life of your installation
—Your trusted partnerKEEP RUNNINGYour operation is critical. Your goal is to extend the life of your installation. These Tmax® XT Retro-fit Kits keep your Spectra™ Panelboards opera-tional and help to minimize costs due to down time. UPDATE YOUR INSTALLATION Update your Spectra™ Panelboards and Switch-boards with the latest in circuit breaker technol-ogy. These retrofit kits enable the installation of the Tmax® XT family of molded circuit breakers. You benefit by gaining the latest capability in cir-cuit protection, communications, and predictive maintenance technologies.GET WHAT YOU NEED WHEN YOU NEED ITYou run lean. You need replacement parts today. Our wide network of distributors give you access to the products you need, when you need them.2
— Table of contents004 – 005 Tmax® XT Retrofit Kits for Spectra™ Panelboards and Switchboards006 – 007 Choosing the right retrofit has never been so easy008 – 009 The Tmax® XT range at a glance010 – 010 Electronic trip units Ekip Dip and Ekip Touch011 – 011 Accessories for Retrofit Kits3
4—Tmax® XT Retrofit Kits for Spectra™ Panelboards and Switchboards The right choice for your applicationSingle mount kits01 available for 250 A, 600 A, 1200 A frames—01 Maximum of two Tmax® XT4, XT5 or XT7 retrofit kits can be installed, side by side, in an existing Spectra™ panelboard installation
5Dual mount kits01 available for 150 A, 250 A, 400 A frames
6—Choosing the right retrofit has never been so easyYou consider what you need. We will show you what's possibleStep 1. Select breaker and trip unitStep 2. Select retrofit kitStep 3. Enter separate breaker and retrofit kit orders through empower.abb.com using desktop, laptop or mobile devices. ABB empowerStep 4. Receive breaker and retrofit kit shipments— 01 Maximum of two Tmax® XT4, XT5 or XT7 retrofit kits can be installed, side by side, in an existing Spectra™ panelboard installation— 02 For instantaneous selectivity, see DET-760. For series ratings, see DET-008.The world of electrical distribution is a complex one, yet choosing the right device for your individual needs has never been simpler thanks to this Tmax® XT retrofit01 offering for Spectra™ Panelboards and Switchboards. Maybe you are looking for a basic protection device for a standard distribution system. Or perhaps you need something more complex, such as a locking mechanisms or devices that integrate protection, automation, measuring and communication into a cloud-based supervision system. Follow the flowchart when placing an order. All mount-ing kits, filler plates and hardware required are included under a single part number. Circuit breakers are ordered separately.02Bolt-on Strap Kits - Type SRFBNeutral CT Kits - Type SRFNExample: Example: SRFB SRFN 6400PolesAmpere Rating3 XT1 = Tmax® XT XT1XT4 = Tmax® XT XT4XT5 = Tmax® XT XT5XT7 = Tmax® XT XT7GF = Tmax® XT Spectra™ Panel Neutral CT kitBlank = Main or BranchB = Branch OnlyM = Main OnlyFPX = FPK = With Filler Plate Kit (full width plates with cutouts for handles, etc.) With Filler Plate Kit and Kirk Lock Provision 6C/B FrameModification CodeMounting Accessory CodeXT1 GFB FPX400 = 400A Tmax® XT XT5 600 = 600A Tmax® XT XT5 800 = 800A Tmax® XT XT7 100 = 1000A Tmax® XT XT7 120 = 1200A Tmax® XT XT7
7— 02 XT7 breaker handle extension included in this kit— 04 XT7 retrofit kit can be used for a main or feeder— 01 Maximum of two Tmax® XT4, XT5 or XT7 retrofit kits can be installed, side by side, in an existing Spectra™ panelboard installation — 03 Kits are only for use with 80% rated breakersPossible combinations within the rangeLegacy Spectra™ breakerSpectra™ E Frame Spectra™ F Frame Spectra™ G Frame Spectra™ K FrameTmax® XT BreakerTmax® XT1 Tmax® XT4 Tmax® XT5 Tmax® XT7Industrial applicationsCommercial and industrial applicationsThermal-magnetic trip unitsElectronic trip units125 A dual mounted 250 A dual mounted 250 A single mountedBox width range / X height Box width range / X heightBox width range / X heightLegacy Spectra™ based Kit – – –Tmax® XT Kit01, 03 Tmax® XT Kit with Kirk lock provisions01, 03 SRFN400GF SRFN600GF SRFN800GF SRFN100GF SRFN120GF 400 A dual mounted 600 A single mounted 1200 A single mountedBox width range / X heightBox width range / X heightBox width range / X heightLegacy Spectra™ based Kit – – –Tmax® XT Kit01, 03 02, 04Tmax® XT Kit with Kirk lock provisions01, 03 02, 04
8TMAX® XT —The Tmax® XT range at a glanceCSA C22.2 StandardsSACE Tmax® XT1"The Founder"Small, reliable, versatile. Your dependable partner for all standard applications.At a glance:• 125 A frame available up to 480 V Delta UL• Ther ma l -m agn et ic , M CS a nd M CP tr i p unit s • Max. interrupt rating of 65 kA at 480 V• Offers savings versus 600 V-rated systems in most distribution applications SACE Tmax® XT4"The Entrepreneur"Capable of supporting both simpleand extremely complex operations.At a glance:• 250 A frame available up to 600 V UL• Thermal-magnetic, MCS, MCP, basic and advanced electronic trip units • Max. interrupt rating of 200 kA at 480 V, 100 kA at 600 V• Advanced electronic trip units offer embedded Bluetooth communication for interaction without direct contactSACE Tmax® XT takes circuit breaking to the next level. Designed to perform at extremely high levels, simple to install and able to provide higher level of safety, there's a frame to meet each of your requirements. From a basic solution for commercial and light industrial applications to advanced, heavy-duty applications with cloud connectivity, SACE Tmax® XT has you covered: securely, professionally and reliably.
SACE Tmax® XT5"The Gamechanger"Compact, powerful and flexible. Shows the world what a circuit breaker of the future can do.At a glance:• 600 A frame available up to 600 V UL• Thermal-magnetic, MCS, MCP, basic and advanced electronic trip units • Max. interrupt rating of 200 kA at 480 V, 100 kA at 600 V• Advanced electronic trip units are future-ready with the ability to download additional measurements and logic in the field from the ABB MarketplaceTMSACE Tmax® XT7"The Superhero"The ultimate choice. Deals with heavy-duty demands effortlessly.At a glance:• 1200 A frame available up to 600 V UL• MCS, MCP, basic and advanced electronic trip units • Max. interrupt rating of 100 kA at 480 V, 65 kA at 600 V• A powerful package capable of monitoring and controlling distribution9
—Electronic trip units Ekip Dip and Ekip TouchProtection and informationAccuracyThermal-magneticEkip TouchEkip DipApplications Advanced functionalitiesDistribution Generator Selectivity Metering Communication ABB Ability MarketplaceTM DC ACTouchDipTMThermal-magnetic trip units Thermal-magnetic trip units are intended for the protection of AC and DC networks. They are a solu-tion for basic protection such as overloads and short-circuits.Ekip Dip trip unitsEkip Dip trip units represent the first level of electronic trip unit and are used to protect AC networks. Compared to thermal-magnetic trip units, they can provide increased accuracy, a wider regulation range, delayed short circuit protection, indi vidual trip information and test capability.Ekip Touch trip unitsEkip Touch trip units offer state-of-the-art technol-ogy for AC-network protection. These trip units in-tegrate a great number of protection and automa-tion functionalities, performed with best-in-class accuracy. Measurement and supervi-sion data can be transmitted both on the local com-munication network (the most popular communica-tion protocols are available) or directly over the Internet. Configuration of the trip unit is extremely user-friendly, mainly on the sizes where a colour touchscreen display is available. Furthermore, as operational requirements evolve, for the first time ever customers can download new functions from the ABB Marketplace, choosing among more than fifty different protection, metering and automa-tion functionalities.Trip unit rangeThe protection units available for the SACE Tmax® XT range is organized in three layers, characterized by increasing performance, interfaces, information sets and integration functions. Each layer includes several trip unit versions, de-signed to match specific application needs such as distribution, generator protection.10SACE TMAX® XT
—Accessories for Retrofit Kits11Neutral Current Transformers for XT5 and XT7XT1 Kirk LockXT7 folding handle reduces handle operation effort and are included in XT7 retrofit kitsXT4 Kirk LockXT5 Kirk LockXT7 Kirk Lock
—its contents – in whole or in parts – is forbidden without All rights reserved—ABB Inc. electrification.us.abb.comGE is a trademark of GE.Manufactured by ABB Inc. under licensefrom General Electric Company.