BROCHUREReliaGear™ lighting panelboardsA safe, smart, and sustainable solution to experience XTreme performance
In our ongoing commitment to offersuperior value at every touch point— from quote to ordering to installation to maintenance — we have combined the best technology of ABB and GE Industrial Solutions to bring you a true breakthrough in lighting panelboards.
Table of contents004 – 005 Introduction006 – 007 Applications008 – 009 XTra value 010 – 013 Choosing the right panel014 – 018 Products in detail019–030 ReliaGear™ Pro-Stock™ lighting panelboards
4 RELIAGEAR LIGHTING PANELBOARDS
5 INTRODUCTIONReliaGear lighting panelboards A smart choice to deliver XTreme performanceOver a century of research and experience results in highly reliable, top-level products that are ready to face all future challenges. By integrating FORMULA A2 and Tmax® XT circuit breakers as mains and sub-feeds in the RQ, RL, RE, RS, and Pro-Stock panels, ABB reveals a new generation of lighting panels with increased breaker density and advanced features to experience Xtreme performance.ReliaGear lighting panelboards are the safe, smart, and sustainable solution for projects of any size that demand quick delivery, ease of installation, design flexibility, and greater versatility.—ReliaGear RS lighting panelboard1. Load end neutral2. (4) Tmax XT4 sub-feeds with a maximum of 5 sub-feeds3. TEYL branch breakers4. Main lug 600 A5. Incoming line of a bottom feed panel6. Ground bars (not shown) are enclosure mounted in either the top or bottom gutters3214566
6 RELIAGEAR LIGHTING PANELBOARDS
7 APPLICATIONSTake your projects to the XTreme Combining ABB and GE Industrial Solutions expertise, we help secure more business and maximize profitsIdeal for:• Commercial and high-rise buildings• Data centers• Educational and institutional facilities• Food and beverage facilities• Health care facilities• Infrastructure projects• Large industrial complexes• And moreReliaGear panelboards are the smart choice for projects of any size and application where XTreme performance matter.Consultants and end usersState-of-the-art technology backed by a long history of success and innovation. Sharing the best of both, ABB and GE Industrial Solutions put highly skilled and experienced engineers at your service to support you before, during, and beyond the product life cycle.ContractorsThe modular and versatile design helps speed installation and dramatically reduces labor costs. DistributorsSame-day availability and exceptional lead times offer a competitive advantage to projects where time is critical.OEMs and panel buildersEase of installation, availability, commonality, functionality and XTreme performance make the ReliaGear lighting panelboard a smart choice.
8 RELIAGEAR LIGHTING PANELBOARDS Technologies that offer XTra value—Easy to installXTremely easy installationThe extruded split neutrals simplify wiring and speed installation. NEMA enclosuresoffer ample gutter space for terminating wires and cables per the NEC code. Moreover, only four mounting screws are required to mount the interior. These unique features help offer a time-saving and easy installation, and minimize any needed wall reconstruction, clean-up, and downtime.—Greater versatilityBreaking a new ground by increasing sub-feed amperageReliaGear lighting panelboards now offer increased amperages and sub-feed circuit counts to feed more downstream loads. Combined with advancedelectronic trip units in compact frames, helps to ensure continuity of service and equipment protection at all times.
9—Design flexibilityAn advanced level of customizationReliaGear lighting panelboards feature a flexible design. Choose from thousands of configurations and add optional embedded SPD, main metering or branch circuit metering to create lighting panelboards that adapt to each customer’s specific need.—Automated logisticsExceptional lead timesThe state-of-the-art automated empower tool facilitates product ordering, helping users save time and money. ABB empower enables product configuration, drawings submittal, detailed quotes and order entry at any time. In addition, empower’s PanelScan solution helps enhance productivity through the automated takeoff of panelboard schedules.XTRA VALUEÑ01
10 RELIAGEAR LIGHTING PANELBOARDS Choosing the right panelReliaGear lighting panelboards are factory assembled on rigid steel frames and equipped with circuit breakers from 15 A to 800 A. The maximum short circuit rating is equal to 65 kAIC at 240 V AC and 480/277 V AC with series rating of 100 kAIC at 480 V AC and 200 kAIC at 240 V AC.ReliaGear lighting panelboards can be used on the following system voltages: United States and Canada• 120/240 V AC; 1-phase, 3-wire• 240 V AC; 3-phase, 3-wire • 240/120V AC; 3-phase, 4 wire (B-phase hi leg)• 480 V AC; 3-phase, 3-wire • 208Y/120 V AC; 3-phase, 4-wire • 480Y/277 V AC; 3-phase, 4-wire International• 380 V AC, 3-phase, 3-wire• 400 V AC, 3-phase, 3-wire• 415 V AC, 3-phase, 3-wire• 220Y/127 V AC, 3-phase, 4- wire• 230Y/127 V AC, 3-phase, 4-wire • 380Y/220 V AC, 3-phase, 4-wire • 400Y/231V AC, 3-phase, 4-wire • 415Y/240V AC, 3-phase, 4-wire
11CHOOSING THE RIGHT PANELThe ReliaGear lighting panelboards are available with multiple options.All ReliaGear lighting panelboards have dual mounted feeders or single mounted sub-feeds. The maximum ampacity of the breakers selected will determine the width of panelboard needed. Feed location: Top or bottomIncoming type: Main lug only (MLO), main circuit breaker (MCB, either vertically or horizontally mounted) and with feed-through lugs or sub-feed breakersBusbar ratings: 125 A, 225 A, 250 A, 400 A, 600 A, 800 ABusbar material: Bare, silver-plated or tin-plated copper, tin-plated aluminum, heat-rated or density-rated (fully)Available environmental enclosure types: • NEMA 1 • NEMA 3R• NEMA 4/4X • NEMA 12Key features• 30" wide options for increased access to gutter space• Blank end walls are standard; end walls with knockouts available as an option• NEMA 4/4X/12 enclosures made of 316 stainless steel or painted galvaneal for harsh indoor/outdoor conditions (corrosion-resistant, water-tight and dust-proof)• Optional locks, Yale, Best, Quarter-turn or Corbin, corrosion-resistant catch and locking door latch offering (doors over 48" high provide two latches)• Optional field-installable metal directory frames available• Lighting contactor and stud only options are available
12 RELIAGEAR LIGHTING PANELBOARDS Molded case circuit breakers3142—Key:1. Current threshold for short circuit protection. 2. Rotary switch for short circuit protection.3. Current threshold for overload protection.4. Rotary switch for overload threshold setting.Tmax® XT trip units — thermal magnetic adjustable and Ekip DIP LSIFrom design to manufacturing, FORMULA A2 and Tmax® XT circuit breakers set the standard for edge technologies to deliver XTreme performance. With superior quality and advanced features such as higher interrupt ratings (up to 200 kA), Ekip DIP and thermal magnetic trip units, FORMULA A2 and Tmax XT circuit breakers support low tier to high tier customers.—Tmax® XT, FORMULA A2, and legacy GE circuit breakersFormula A2 XT1 XT4 XT5 XT6THQB (bolt-on)THQL (plug-on)THHQB (bolt-on)THHQL (plug-on) TEY TEYF TEYD TEYH TEYLFrame size (A) Poles † † Amperage (A) ‡Max. rated voltage (V) Trip units Thermal magnetic fixed (TMF)Thermal magnetic fixed (TMF)Thermal magnetic fixed (TMF) Ekip DIP LSIThermal magnetic adjustable (TMA) Ekip DIP LSIThermal magnetic adjustable (TMA) Ekip DIP LSIFixed Fixed Fixed Fixed Fixed Fixed FixedMax. interrupting rating (kA) 3-pole can be used in a 2-pole application ReliaGear lighting panelboard is rated up to 65 kAIC.‡ †1-pole max. (kA) 14Note: Formula A2 replaces TQD and THQD | XT1 or XT4 replaces SE | XT4 replaces SF | XT5 replaces SG | XT6 replaces SKTMF: Thermo-Mag Fixed: No Adjustments PossibleTMA: Thermo-Mag Adjustable: Adjustable Thermal (L) & Magnetic (I)—Thermal magnetic adjustable
13CHOOSING THE RIGHT PANEL12534—Key:1.DIP switches for overload protection setting.2. DIP switches for short circuit and time-delayed short circuit protection settings.3. Slot for lead seal.4. Test connector.5. Power-on LED. —Tmax® XT, FORMULA A2, and legacy GE circuit breakersFormula A2 XT1 XT4 XT5 XT6THQB (bolt-on)THQL (plug-on)THHQB (bolt-on)THHQL (plug-on) TEY TEYF TEYD TEYH TEYLFrame size (A) Poles † † Amperage (A) ‡Max. rated voltage (V) Trip units Thermal magnetic fixed (TMF)Thermal magnetic fixed (TMF)Thermal magnetic fixed (TMF) Ekip DIP LSIThermal magnetic adjustable (TMA) Ekip DIP LSIThermal magnetic adjustable (TMA) Ekip DIP LSIFixed Fixed Fixed Fixed Fixed Fixed FixedMax. interrupting rating (kA) 3-pole can be used in a 2-pole application ReliaGear lighting panelboard is rated up to 65 kAIC.‡ †1-pole max. (kA) 14Note: Formula A2 replaces TQD and THQD | XT1 or XT4 replaces SE | XT4 replaces SF | XT5 replaces SG | XT6 replaces SKTMF: Thermo-Mag Fixed: No Adjustments PossibleTMA: Thermo-Mag Adjustable: Adjustable Thermal (L) & Magnetic (I)—Ekip DIP LSI or adjustable L, S, and I
14 RELIAGEAR LIGHTING PANELBOARDS Products in detailRQ • 240 V max., 1- or 3-phase• • RQ: Bolt-on THQB breakersRL • 240 V max., 1- or 3-phase• • RL: Plug-in THQL breakers—ReliaGear RQ lighting panelboard (as shown on left)1. Bolt-on THQB branch breakers2. Formula A2 horizontal sub-feed breaker3. Main breaker: Tmax XT5, Tmax XT trip unit: thermal-mag adjustable (TMA)4. Bottom feed—ReliaGear RL lighting panelboard (as shown on right)1. NEMA 1 enclosure —surface mounted2. Plug-in THQL branch breakers3. Sub-feed branch mounted breaker: Formula A2, Formula A2 trip unit: thermal-mag fixed (TMF)4. Main breaker: Tmax XT5 Tmax XT trip unit: thermal-mag adjustable (TMA) 5. Bottom feed1234512345
15PRODUCTS IN DETAILRL • 240 V max., 1- or 3-phase• • RL: Plug-in THQL breakersRE • 480Y/277 V max., 3-phase• • RE: 18 kAIC at 480Y/277 V; 65 kAIC at 240 V• RE: Bolt-on TEY(F) breakers• Main lugs 125-800A up to 250VDC & Main breaker 125A at 250VDC maxRS • 480Y/277 V max., 3-phase• • RS: 100 kAIC at 240 V; 65 kAIC at 480 V• RS: Bolt-on TEY(D/H/L) breakers• Main lugs 125-800A up to 250VDC & Main breaker 125A at 250VDC max—ReliaGear RE lighting panelboard (as shown on left)1. Main breaker: Tmax XT5, Tmax XT trip unit: thermal-mag adjustable (TMA) 2. Skewed neutrals for 200% neutral or feed-thru lugs at 600 A3. Bolt-on TEYF branch breakers4. Optional feed-thru lugs require extended bus bar—ReliaGear RS lighting panelboard (as shown on right)1. Incoming cable gutter space 2. Main breaker: Tmax XT5, Tmax XT trip unit: thermal-mag adjustable (TMA) 3. Bolt-on TEYL branch breakers 4. End walls with knockouts available as an option in NEMA 1 enclosures11223 344
16 RELIAGEAR LIGHTING PANELBOARDS —NEMA 1—NEMA 3R—NEMA 4/4X/12 painted galvaneal, 30" wide—NEMA 4/4X/12 stainless steelNEMA 1 enclosures with 3 frontsNEMA 1 Enclosures are available with 3 fronts. The black end walls are standard, and knockouts are available optionally. Plus, the corrosion-resistant lock with a catch and locking door latch adds an extra level of protection and safety and make them ideal for outdoor installations.NEMA 3R, 4 and 12 enclosures galvanised steel coatedThe NEMA 3R, 4, and 12 enclosures feature a standard padlock-able handle feature. They are galvanised steel coated with Pulvalar 115 powder coating (Glidden Coatings & Resins, SCM Corp.), which make them surpass stainless steel in NEMA 4/4X testing requirements. These enclosures also passed ASTM B117-1985 200 hr salt spray test with no deterioration. NEMA 3R, 4X and 12 rated stainless steel enclosuresThe NEMA 3R, 4X and 12 enclosures are rated stainless steel which made them corrosion-resistant. They provide flexibility of use with several NEMA ratings. Their design features a gasketed door and a 3-point catch handle for easier access and service. NEMA enclosures for ReliaGear lighting panels All NEMA enclosures are built with high-quality materials and designed to last. They all are UL/ cULus listed - UL Listed file #E21789. Plus, deep and wide options are available for 800A panels (add “DW” suffix to catalog number, 600A max for Canada). The three categories below group the enclosures based on their remarkable characteristics.
17—Door within door—Standard—Front hinged to boxStandardThe standard front finish with ANSI grey polyester-coded paints. This front is equipped with concealed hinges and trim adjusting screens.Door within doorConvenient for contractors to get easy access to equipment from the front of the panel, the inner door allows to service the breaker without removing the front to access the gutters for infrared scans and pulling new wires for circuits. Front hinged to boxFront hinged to box fronts are a cost-effective option for small projects. This door allows removing 4 screws to get to the outer door for gutter access. Likewise, the inner door opens to the breaker.PRO-STOCK PANELBOARDSReliaGear lighting panel fronts for NEMA 1 enclosures The robust and convenient ReliaGear lighting panel fronts for NEMA 1 enclosures include director holders as an option to mount to the door for availability to panelboard configurations. Lighting contactor and stud only are also available as options. The fronts are available as standard, door within door, and front hinged door.—Standard with quarter turn lock
18 RELIAGEAR LIGHTING PANELBOARDS Optional featuresAMP1 integrated power and energy meter The AMP1 integrated power and energy meter monitors key electrical parameters of the main power coming into the panelboard. The factory-installed AMP1 meter is a completely integrated solution ideal for tenant billing and cost allocation.Key features• Up to 800 A• Data logging• Communicates via Modbus RTU or BACnet• Externally mounted retrofit kits availableBranch circuit monitoring (BCM)Branch circuit monitoring (BCM) helps deliver valuable and precise branch usage data on each individual branch circuit, enabling users to analyze and identify potential cost-saving actions.Key features• Solid core branch circuit monitoring for 42 or 84 circuits with optional mains• Split core monitors up to 66 circuits in a main breaker panel and up to 84 circuits in a main lug panel• Communicates with Modbus RTU via RS485Surge protective device (SPD)The ReliaGear lighting panelboard offers integrated SPDs with ratings of 100 kA, 80 kA and 65 kA per mode. Box extension SPDs are also offered in the ReliaGear lighting panelboards for new or aftermarket installations. The box extension can be attached precisely to a standard panel at the top or bottom without creating additional width or depth satisfying customer project requirements.Key features• 10 modes of protection (L-N, L-G, N-G, L-L) • Green status indicating lights, red service light • Audible alarm with test/disable featureASHRAE 90.1, CA Title 24 & IECC solutionsBranch circuit monitoring (BCM) upgradeable panels, splits-bus panels, and AMP1 single point metering are designed to meet California Title 24, part 6, §130.5(b), ASHRAE 90.1-2013, and IECC’s building energy efficiency standards.
ARTICLE OR CHAPTER TITLE 19Do you need your lighting panelboard now?ASK FOR RELIAGEAR™ PRO-STOCK™
20 RELIAGEAR LIGHTING PANELBOARDS With same-day availability and exceptional lead times, ReliaGear Pro-Stock lighting panelboards offer a competitive advantage for projects where time is critical.
ARTICLE OR CHAPTER TITLE 21ReliaGear Pro-Stock panelboardsFlexibility to the XTremeReliaGear Pro-Stock panelboards offer a symmetrical design for top or bottom feed with main breaker or main lugs. With a reversible interior, there is no need to specify top or bottom feed. Modular kits are available from inventory for immediate availability to your customers in over 1,500 panel designs. Key features• All panels are convertible between main lugs or main breaker• Main bus ratings of 225 A, 400 A and 600 A available• • 240 V AC 1- or 3-phase or 480Y/277 V AC 3-phaseApplicationsReliaGear Pro-Stock lighting panelboards are used for small projects and non-specific applications that are needed fast. • Emergency situations like • Natural disasters or • Property damage • Storage units• Strip malls• Subways• Small businesses• Small buildings, and morePRO-STOCK PANELBOARDS
22 RELIAGEAR LIGHTING PANELBOARDS Engineered for projects with short turn around, ReliaGear™ Pro-Stock™ lighting panelboards are a smart investment when operational downtime can't be afforded.
23PRO-STOCK PANELBOARDSAssemble and install on site in about 30 minutesNo lead time Standard parts+1K configurationsProjects with short turn aroundXTra value at every levelEmergency situations property damage, strip malls, subways, small business or buildings7 parts to complete your selectionUnassembledAvailable immediately on your distributors’ shelvesXTreme flexibility to meet your application requirementsA smart investment when operational downtime can’t be afforded
24 RELIAGEAR LIGHTING PANELBOARDS ReliaGear Pro-Stock panelboards100–600 A—ReliaGear Pro-Stock lighting panel 1. Horizontal-mounted main breaker: Tmax XT4, Tmax XT trip unit: thermal-mag adjustable (TMA) 2. Full-panel height neutral bar connections (on the right and left)3. THQB branch breakers4. Horizontal-mounted sub-feed breaker: Formula A25. End walls with knockouts available as an option in NEMA 1 enclosuresFull-panel height neutral bar connections for point-of-ease installations with improvements in wire bending space and ease of connections to breakers.12345
25PRO-STOCK PANELBOARDSPro-Stock lighting panelboardsUnassembled lighting panels—Aluminum bus Voltage Rating (amps) No. of circuitsFeed-thru Product number Box/front height (in.) TGL2 ground bars1,2 V AC, V AC, —TGL20 ground lug quantities Interior typeNo. of TGL20s required by panel rating100 A–225 A 400 A 600 AMain lug only Main lug and feed-thru Main breaker only Main breaker and sub-feed Main breaker and feed-thru 1 For TGL20 ground lug quantities, see TGL20 ground lug quantities table above.2 For isolated ground, use EGS12. When using the EGS12, 3, 5 and 7 ground lugs (TGL20s) are required for 18, 30 and 42 circuits respectively.Pro-Stock lighting panelboards are XTtremely easy to install. A Pro-Stock lighting panel can be installed in less than 30 minutes with only three tools.Using the empower configuration tool, follow the steps below to build a ReliaGear Pro-Stock lighting panelboard:1. Select interiorSelect the interior by bus type, panel rating and number of circuits. Identify the box/front height for use in steps 2 and 3.—Copper bus Voltage Rating (amps) No. of circuitsFeed-thru Non feed-thruProduct number1Box/front height (in.) Product number1Box/front height (in.) TGL2 ground bars1,2 V AC, V AC,
26 RELIAGEAR LIGHTING PANELBOARDS 2. Choose boxSelect a box of the correct height (see step 1). Boxes come with blank endwalls.If endwalls with knockouts are required, also order knockout endwall kit AKEW2.Note: This is only available for 20" wide NEMA 1 enclosures.3. Add a frontAdd a front of the correct height (available for NEMA 1 enclosures only)Box height (in.)NEMA 1 NEMA 3R NEMA 4, 4X and 12 painted galvaneal NEMA 4, 4X and 12 stainless steel20" Wide 20" Wide 20" Wide 20" Wide Front height (in.)Standard (20" wide) Door within door (20" wide) Front hinged to box (20" wide)Flush (*T) Surface (*T) Flush Surface Flush Surface Pro-Stock lighting panelboardsUnassembled lighting panels—NEMA 1—Door within door—Standard—Front hinged to box—NEMA 3R• Standard fronts are equipped with concealed hinges and trim adjusting screws hinges, trim adjusting screws and quarter turn locks. • The door-in-door is convenient for contractors to gain easy access to equipment from the front of the panel. Door-in-door allows a contractor access to the gutters without removing the front.• Front hinged to box is similar to door-in-door for convenient access to gutters, but a contractor must remove four screws to access the outer door.—NEMA 4/4X/12 stainless steel—Standard with quarter turn lock
27Pro-Stock lighting panelboardsUnassembled lighting panels4. Select main and/or sub-feed breaker kitSelect the main breaker kit appropriate for your interior type (see step 1), amp rating and kAIC rating. If a sub-feed breaker is required, repeat the selection process.Interior type Cat. no.(1)Rating (Amps)No. of polesBreaker short circuit rating (kAIC)10 14 22 25 35 50 65 100 150 200 THQB THHQB THQB THHQB TEY (1) Breaker not included except for “WB” kits (where product number ends in “WB”). “WB” kits include a breaker, mounting kit and load-side lugs.(2) Actual breaker short circuit rating is 25 kAIC.(3) Use 2 outer poles for 3 pole applications(4) For sub-feed application only. (5) 6 poles of sub-feed applies only to 400 A and 600 A interiors.(6) Can use (2) 3 pole devices only, no 2 pole allowed —MBA16—MBA13—MBB33WBPRO-STOCK PANELBOARDS
28 RELIAGEAR LIGHTING PANELBOARDS Pro-Stock lighting panelboardsUnassembled lighting panelsPro-Stock lighting panelboardsUnassembled lighting panels5. Select alternative main breakers• Skip step 5 if you selected a main breaker kit ending in “WB” — no breaker is required.• To correlate breaker types with the kAIC rating in specific panelboards, see the table for step 4. For more rating details, see ReliaGear lighting panels rating series labels (1TQC173100E0001).• Tmax XT5 breakers require both line and load side lug options• Use 2 outer poles for 3 pole applications• For TEY and THQB main breakers, see branch breakers tables in step 7.—Tmax XT breakers (3-pole) for use with appropriate main breaker kit (see step 4). 240V KAIC 480V KAIC Breaker Description US Product number Wire range (Cu/Al) Cables per lug —Main or sub-feed breakers for use with RQ panels (208/120 V AC 3-phase or 240 V AC single-phase). See step 4. Amp rating2-pole 3-pole10 kAIC 22 kAIC 10 kAIC 22 kAICProduct3 number Product number Product number Product number
296. Select main lug kit and accessoriesSelect lug kit(s) for main lug and/or feed-thru applications, if required. All lugs are suitable for interiors with either copper or aluminum bus. Also select any accessories required.—Main lug kits Lug type Amp ratingStandard Oversized 200% NeutralProduct number Wire range Product number Wire range Product numberPressure NKA Copper NKR Compression NKT Dual Main 1 500 kcmil Cu, 750 kcmil Al.2 —Accessories Service entrance3Amp rating Product number BNDKT 3 Service entrance kit includes a bonding strap with hardware and a service entrance label.ProCare kit4Description Product numberProCare Kit for Pro-Stock panelboard installation and maintenancePROCARE4 ProCare Kit includes: (5) filler plate hardware kits, (9) bus stud nuts, (5) MLA1 filler plates, (2) 225A-phase barriers, (2) feed-thru barriers, (1) 400/600A-phase barrier, RE front hardware kits, (10) AD front hardware kits, (50) service disconnect labels, (50) main labels.Pro-Stock lighting panelboardsUnassembled lighting panelsPRO-STOCK PANELBOARDSSpare lugsFrame Poles Cat. No Kits include 3pcs lugWire-Cu-Al (Unless otherwise specificied)Per Lug Range External solution: lugs to be mounted on EF terminals in the kit
30 RE LIAGEAR LIGHTING PANELBOARDS 7. Select bolt-on branch breakersThe tables below show standard branch breakers. —Branch circuit breakers for use with RQ panels (208/120 V AC 3-phase or 240 V AC single-phase) Amp rating10 kAIC 22 kAIC1-pole 2-pole 3-pole 1-pole 2-pole 3-poleProduct number Product number Product number Product number Product number Product number —Branch circuit breakers for use with RE panels (480/277 V AC 3-phase) Amp rating14 kAIC1-pole 2-pole 3-poleProduct number Product number Product number Pro-Stock lighting panelboardsUnassembled lighting panels8. The selection is completed, now submit your orderFor more information or support, please contact your ABB local representative or visit ReliaGear lighting panelboards product page.
ARTICLE OR CHAPTER TITLE 31
—ABB Inc.Electrification business 305 Gregson Dr.Cary, NC 27511 electrification.us.abb.com1TQC173600E0001 PG REV.I MAY 2021—We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders and/or contracts, the agreed particulars shall prevail. ABB Inc. does not accept any responsibility whatsoever for potential errors or possible lack of information in this document.We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction or utilization of its without prior written consent of ABB Inc.GE is a trademark of GE. Manufactured by ABB Inc. under license from GE.© Copyright 2021 ABB. All rights reserved.