Return to flip book view

Alex-Tronix Catalog Vol. 3

Page 1


Alex-Tronix The Standard in Filter Backwash Controls   Product Catalog Vol. 3 Proudly Celebrating 40 Years  Made in the USA Website: alextronix.com                                      Phone: (559) 276-2888 Fax: (559) 276-2890                                                            Toll Free: (888) 224-7630 




Page 2

Page 3

Our New Line of Filter Backwash Controllers Featuring: • 1-32 station flexibility • New 1-30 psi digital pressure differential sensor (SPD) with reading viewable on display • UL Listed 4 or 8 station model • Outdoor enclosures designed to meet NEMA 4X rating (some models) • One-second timing increments • Selectable progressive or sequential stations (most models) • Solar panel option *Filter Master Series Controller Selection Chart in Back INTRODUCING THE FILTER MASTER SERIES FM-2DCL FM-4P FM-4/8 FM-12/16/32 SPD FM-4/8UL

Page 4

FM-2DCL Product Overview • One Station Plus Master Valve or 2 Stations • New 1-30 psi digital pressure differential sensor (SPD) with reading viewable on display (optional) • Input: 4 AA Batteries • Outputs: 12 VDC 2-Wire Latching Solenoids • 10,000 Cycles or 1 season with Supplied Lithium AA Batteries • PD Delay-Adjustable • Resettable Backwash Count • Actuation Method: Periodic, Manual, or PD • One-Second Timing Increments • Optional Murphy Pressure Differential Gauge (PDMU) • 2-Year Warranty on Controller 1-2 Stations Battery Operated Outdoor Enclosure Alex-Tronix The Standard in Filter Backwash Controls

Page 5

FM-2 DCL Features and Options STANDARD FEATURES NUMBER OF STATIONS PLUS MASTER VALVE 1 Plus Master Valve or 2 INPUT VOLTAGE 4 AA Baeries STATION SEQUENCE Sequenal PD DELAY Adjustable OUTPUT 12 VDC 2-Wire Latching Solenoids RESETTABLE BACKWASH COUNT ✓ ENCLOSURE TYPE Rust-Proof Outdoor ACTUATION METHOD PERIODIC, MANUAL, OR PD ✓ SIMPLE PROGRAMMING ✓ 2 YEAR WARRANTY ✓ OPTIONS NEW SPD 1-30 PSI DIGITAL READ PD SENSOR Oponal PDMU 1-15 PSI MURPHY PD GAUGE Oponal PDBRKT MOUNTING BRACKET FOR PDMU Oponal DIMENSIONS HEIGHT (in) 9.5 WIDTH (in) 7.8 DEPTH (in) 4 SHIPPING WEIGHT (lb) 2.5

Page 6

Alex-Tronix FM-4P Product Overview • 4 Stations Plus Master Valve • New 1-30 psi digital pressure differential sensor (SPD) with reading viewable on display • Input: 115 or Optional 230 VAC 50/60 Hz, or 12-15 VDC • Outputs: 24 VAC, 12 VDC, or 12 VDC 2-Wire Latching Solenoids • Progressive or Sequential Stations • PD Delay-Adjustable • Resettable Backwash Count • Actuation Method: Periodic, Manual, or PD • One-Second Timing Increments • Heavy Duty Transformer Option • Solar Panel Option • 2-Year Warranty The Standard in Filter Backwash Controls 4 Stations Plus Master Valve Outdoor Enclosure Display Externally Visible Through Window New Pressure Differential Sensor (SPD) Included

Page 7

FM-4P Features and Options STANDARD FEATURES FM-4P NUMBER OF STATIONS PLUS MASTER VALVE 4 INPUT VOLTAGE 115 VAC 50/60 Hz, or 12-15 VDC OUTPUTS 24 VAC, 12 VDC, or 12 VDC 2-Wire Latching Solenoids SELECTABLE STATION SEQUENCE PROGRESSIVE ✓ SEQUENTIAL ✓ NEW SPD INCLUDED 1-30 PSI DIGITAL READ SENSOR PD ✓ PD DELAY Adjustable SWING OUT, PLUG IN FRONT PANEL Screw-In Panel RESETTABLE BACKWASH COUNT ✓ ENCLOSURE TYPE Rust-Proof Outdoor ACTUATION METHOD PERIODIC, MANUAL, OR PD ✓ SIMPLE PROGRAMMING ✓ 2 YEAR WARRANTY ✓ OPTIONS SP5 5 WATT SOLAR PANEL Oponal SP5 BRKT MOUNTING BRACKET FOR SP5 Oponal PDMU 1-15 PSI MURPHY PD GAUGE Oponal PDBRKT MOUNTING BRACKET FOR PDMU Oponal BATT-7 7 AMP-HOUR BATTERY FOR DCL MODELS Oponal T-230 230 VAC TRANSFORMER Oponal T-115HD 115 VAC HEAVY DUTY TRANSFORMER Oponal T-230HD 230 VAC HEAVY DUTY TRANSFORMER Oponal DIMENSIONS HEIGHT (in) 10 WIDTH (in) 7 DEPTH (in) 4 SHIPPING WEIGHT (lb) 5

Page 8

Alex-Tronix FM-4/8 Product Overview • 4 or 8 Stations Plus Master Valve • New 1-30 psi digital pressure differential sensor (SPD) with reading viewable on display • Input: 115 or Optional 230 VAC 50/60 Hz, or 12-15 VDC • Outputs: 24 VAC, 12 VDC, or 12 VDC 2-Wire Latching Solenoids • Progressive or Sequential Stations • PD Delay-Adjustable • Resettable Backwash Count • Actuation Method: Periodic, Manual, or PD • One-Second Timing Increments • Heavy Duty Transformer Option • Solar Panel Option • PD Alarm • 2-Year Warranty The Standard in Filter Backwash Controls 4 or 8 Stations Plus Master Enclosure Designed to meet NEMA 4X Rating New Pressure Differential Sensor (SPD) Included

Page 9

FM-4/8 Features and Options STANDARD FEATURES FM-4/8 NUMBER OF STATIONS PLUS MASTER VALVE 4 or 8 INPUT VOLTAGE 115 VAC 50/60 Hz, or 12-15 VDC OUTPUTS 24 VAC, 12 VDC, or 12 VDC 2-Wire Latching Solenoids SELECTABLE STATION SEQUENCE PROGRESSIVE ✓ SEQUENTIAL ✓ NEW SPD INCLUDED 1-30 PSI DIGITAL READ SENSOR PD ✓ PD DELAY Adjustable SWING OUT, PLUG IN FRONT PANEL ✓ RESETTABLE BACKWASH COUNT ✓ ALARM FEATURE ✓ ENCLOSURE TYPE RUGGED OUTDOOR TYPE IP 66 DUST TIGHT, PROTECTS AGAINST JETS OF WATER Designed to Meet NEMA 4X Rang ACTUATION METHOD PERIODIC, MANUAL, OR PD ✓ SIMPLE PROGRAMMING ✓ 2 YEAR WARRANTY ✓ OPTIONS SP5 5 WATT SOLAR PANEL Oponal SP5 BRKT MOUNTING BRACKET FOR SP5 Oponal PDMU 1-15 PSI MURPHY PD GAUGE Oponal PDBRKT MOUNTING BRACKET FOR PDMU Oponal BATT-7 7 AMP-HOUR BATTERY FOR DCL MODELS Oponal T-230 230 VAC TRANSFORMER Oponal T-115HD 115 VAC HEAVY DUTY TRANSFORMER Oponal T-230HD 230 VAC HEAVY DUTY TRANSFORMER Oponal DIMENSIONS HEIGHT (in) 12 WIDTH (in) 10 DEPTH (in) 5.5 SHIPPING WEIGHT (lb) 9.0

Page 10

Alex-Tronix FM 4/8UL Product Overview • 4 or 8 Stations Plus Master Valve • UL Listed in NEMA 4X Rated Enclosure • New 1-30 psi digital pressure differential sensor (SPD) with reading viewable on display • Input: 115 or Optional 230 VAC 50/60 Hz • Outputs: 24 VAC, 12 VDC, or 12 VDC 2-Wire Latching Solenoids • Progressive or Sequential Stations • PD Delay-Adjustable • Resettable Backwash Count • Actuation Method: Periodic, Manual, or PD • One-Second Timing Increments • PD Alarm • 2-Year Warranty The Standard in Filter Backwash Controls 4 or 8 Stations Plus Master Valve UL Listed New Pressure Differential Sensor (SPD) Included

Page 11

FM-4/8 UL Features and Options STANDARD FEATURES FM-4/8 UL NUMBER OF STATIONS PLUS MASTER VALVE 4 OR 8 INPUT VOLTAGE 115 VAC 50/60 Hz OUTPUTS 24 VAC, 12 VDC, or 12 VDC 2–Wire Latching Solenoids SELECTABLE STATION SEQUENCE PROGRESSIVE ✓ SEQUENTIAL ✓ NEW SPD INCLUDED 1-30 PSI DIGITAL READ SENSOR PD ✓ PD DELAY Adjustable SWING OUT, PLUG IN FRONT PANEL ✓ RESETTABLE BACKWASH COUNT ✓ ALARM FEATURE ✓ ENCLOSURE TYPE RUGGED OUTDOOR TYPE IP 66 DUST TIGHT, PROTECTS AGAINST JETS OF WATER Designed to Meet NEMA 4X Rang ACTUATION METHOD PERIODIC, MANUAL, OR PD ✓ SIMPLE PROGRAMMING ✓ 2 YEAR WARRANTY ✓ OPTIONS PDMU 1-15 PSI MURPHY PD GAUGE Oponal PDBRKT MOUNTING BRACKET FOR PDMU Oponal T-230 230 VAC TRANSFORMER Oponal DIMENSIONS HEIGHT (in) 12 WIDTH (in) 10 DEPTH (in) 5.5 SHIPPING WEIGHT (lb) 9.5

Page 12

Alex-Tronix FM-12/16/32 Product Overview • 12,16 or 32 Stations Plus Master Valve • New 1-30 psi digital pressure differential sensor (SPD) with reading viewable on display • Input: 115 or Optional 230 VAC 50/60 Hz, or 12-15 VDC • Outputs: 24 VAC, 12 VDC, or 12 VDC 2-Wire Latching Solenoids • Progressive or Sequential Stations • PD Delay-Adjustable • Resettable Backwash Count • Actuation Type: Periodic, Manual, or PD • One-Second Timing Increments • Heavy Duty Transformer Option • Solar Panel Option • PD Alarm • 2-Year Warranty The Standard in Filter Backwash Controls 12, 16 or 32 Stations Plus Master Valve FM-12/16 Easy Plug-in Retrofit from existing F12/16 AC/DC/DCL Powder Coated Steel Enclosure New Pressure Differential Sensor (SPD) Included

Page 13

FM-12/16/32 Features and Options STANDARD FEATURES FM-12/16/32 NUMBER OF STATIONS PLUS MASTER VALVE 12, 16, or 32 Staons INPUT VOLTAGE 115 VAC 50/60 Hz, or 12-15 VDC OUTPUTS 24 VAC, 12 VDC, Or 12 VDC 2-Wire Latching Solenoids SELECTABLE STATION SEQUENCE PROGRESSIVE ✓ SEQUENTIAL ✓ NEW SPD INCLUDED 1-30 PSI DIGITAL READ SENSOR PD ✓ PD DELAY ✓ SWING OUT, PLUG IN FRONT PANEL ✓ RESETTABLE BACKWASH COUNT ✓ ALARM FEATURE ✓ ENCLOSURE TYPE Powder-Coated Steel ACTUATION METHOD PERIODIC, MANUAL, OR PD ✓ SIMPLE PROGRAMMING ✓ 2 YEAR WARRANTY ✓ EASY PANEL SWAP WITH F-SERIES FM-12/16 from F12/16 OPTIONS SP5 5 WATT SOLAR PANEL Oponal SP5 BRKT MOUNTING BRACKET FOR SP5 Oponal PDMU 1-15 PSI MURPHY PD GAUGE Oponal PDBRKT MOUNTING BRACKET FOR PDMU Oponal BATT-7 7 AMP-HOUR BATTERY FOR DCL MODELS Oponal T-230 230 VAC TRANSFORMER Oponal T-115HD 115 VAC HEAVY DUTY TRANSFORMER Oponal T-230HD 230 VAC HEAVY DUTY TRANSFORMER Oponal DIMENSIONS HEIGHT (in) 9.5 WIDTH (in) 13 DEPTH (in) 5.25 SHIPPING WEIGHT (lb) 12

Page 14

Our classic designed filter backwash controllers that set the standard for quality and reliability THE F-SERIES F2-AC/DC-D F3-AC/DC/DCL F4/8-AC/DC/DCL F12/16-AC/DC/DCL *F-Series Controller Selection Chart in Back

Page 15

Alex-Tronix F2AC/DC-D Product Overview • 2 Stations Plus Master Valve • Input: 115 or Optional 230 VAC 50/60 Hz, or 12-15 VDC • Outputs: 24 VAC, or 12 VDC Non-Latching Solenoids • Sequential Station Sequence • PD Delay-Fixed • Resettable Backwash Count • Actuation Method: Periodic, Manual, or PD • Solar Panel Option • Murphy PD Gauge Included • PD Alarm • 2-Year Warranty The Standard in Filter Backwash Controls 2 Stations Plus Master Valve Rust-Proof Outdoor Enclosure Display Visible through Window

Page 16

F2 AC/DC-D Features and Options STANDARD FEATURES F2 AC/DC-D NUMBER OF STATIONS PLUS MASTER VALVE 2 INPUT VOLTAGE 115 VAC 50/60 Hz, or 12-15 VDC OUTPUTS 24 VAC or 12 VDC Non-Latching Solenoids PDMU INCLUDED 1-15 PSI MURPHY PD GAUGE W/BRKT ✓ PD DELAY Fixed RESETTABLE BACKWASH COUNT ✓ ALARM ✓ ENCLOSURE TYPE Rust-Proof Outdoor ACTUATION METHOD PERIODIC, MANUAL OR PD ✓ SIMPLE PROGRAMMING ✓ 2 YEAR WARRANTY ✓ OPTIONS T-230 230 VAC TRANSFORMER Oponal T-115HD HEAVY DUTY 115VAC TRANSFORMER Oponal T-230HD HEAVY DUTY 230VAC TRANSFORMER Oponal DIMENSIONS HEIGHT (in) 9.5 WIDTH (in) 7.8 DEPTH (in) 4.0 SHIPPING WEIGHT (lb) 5.0

Page 17

Alex-Tronix F3AC/DC/DCL Product Overview • 3 Stations Plus Master Valve • Input: 115 or Optional 230 VAC 50/60 Hz, or 12-15 VDC • Outputs: 24 VAC, 12 VDC, or 12 VDC 2-Wire Latching Solenoids • Sequential Station Sequence • PD Delay-Fixed • Resettable Backwash Count • Actuation Method: Periodic, Manual, or PD • Solar Panel Option • Murphy PD Gauge Included • 2-Year Warranty The Standard in Filter Backwash Controls 3 Stations Plus Master Valve Powder Coated Steel Enclosure

Page 18

F3 AC/DC/DCL Features and Options STANDARD FEATURES F3 AC/DC/DCL NUMBER OF STATIONS PLUS MASTER VALVE 3 INPUT VOLTAGE 115 VAC 50/60 Hz, or 12-5 VDC OUTPUTS 24 VAC, 12 VDC, or 12 VDC 2-Wire Latching Solenoids PDMU INCLUDED 1-15 PSI MURPHY PD GAUGE ✓ PD DELAY Fixed SWING OUT,PLUG IN FRONT PANEL ✓ RESETTABLE BACKWASH COUNT ✓ ENCLOSURE TYPE Powder-Coated Steel ACTUATION METHOD PERIODIC, MANUAL OR PD ✓ SIMPLE PROGRAMMING ✓ 2 YEAR WARRANTY ✓ OPTIONS SP5 5 WATT SOLAR PANEL Oponal SP5 BRKT MOUNTING BRACKET FOR SP5 Oponal BATT-7 7 AMP-HOUR BATTERY FOR DCL MODELS Oponal T-230 230 VAC TRANSFORMER Oponal T-115HD HEAVY DUTY 115 VAC TRANSFORMER Oponal T-230HD HEAVY DUTY 230 VAC TRANSFORMER Oponal PDBRKT MOUNTING BRACKET FOR PDMU Oponal DIMENSIONS HEIGHT (in) 8.25 WIDTH (in) 7.5 DEPTH (in) 5.0 SHIPPING WEIGHT (lb) 9.0

Page 19

Alex-Tronix F4/8 AC/DC/DCL Product Overview • 4 or 8 Stations Plus Master Valve • Input: 115 or Optional 230 VAC 50/60 Hz, or 12-15 VDC • Outputs: 24 VAC, 12 VDC, or 12 VDC 2-Wire Latching Solenoids • Sequential Station Sequence • PD Delay-Adjustable • Resettable Backwash Count • Actuation Method: Periodic, Manual, or PD • Solar Panel Option • Murphy PD Gauge Included • PD Alarm • 2-Year Warranty The Standard in Filter Backwash Controls 4 or 8 Stations Plus Master Valve Powder Coated Steel Enclosure

Page 20

F4/8 AC/DC/DCL Features and Options STANDARD FEATURES F4/8 AC/DC/DCL NUMBER OF STATIONS PLUS MASTER VALVE 4 or 8 INPUT VOLTAGE 115 VAC 50/60 Hz, or 12-15 VDC OUTPUTS 24 VAC, 12 VDC, or 12 VDC 2-Wire Latching Solenoids PDMU INCLUDED 1-15 PSI MURPHY PD GAUGE ✓ PD DELAY Adjustable SWING OUT,PLUG IN FRONT PANEL ✓ RESETTABLE BACKWASH COUNT ✓ ALARM ✓ ENCLOSURE TYPE Powder-Coated Steel ACTUATION METHOD PERIODIC, MANUAL OR PD ✓ SIMPLE PROGRAMMING ✓ 2 YEAR WARRANTY ✓ OPTIONS SP5 5 WATT SOLAR PANEL Oponal SP5 BRKT MOUNTING BRACKET FOR SP5 Oponal BATT-7 7 AMP-HR BATTERY FOR DCL MODELS Oponal T-230 230 VAC TRANSFORMER Oponal T-115HD HEAVY DUTY 115 VAC TRANSFORMER Oponal T-230HD HEAVY DUTY 230 VAC TRANSFORMER Oponal PDBRKT MOUNTING BRACKET FOR PDMU Oponal DIMENSIONS HEIGHT (in) 8.25 WIDTH (in) 7.5 DEPTH (in) 5.0 SHIPPING WEIGHT (lb) 9.0

Page 21

Alex-Tronix F12/16 AC/DC/DCL Product Overview • 12 or 16 Stations Plus Master Valve • Input: 115 or Optional 230 VAC 50/60 Hz, or 12-15 VDC • Outputs: 24 VAC, 12 VDC, or 12 VDC 2-Wire Latching Solenoids • Sequential Station Sequence • PD Delay-Adjustable • Resettable Backwash Count • Actuation Method: Periodic, Manual, or PD • Solar Panel Option • Murphy PD Gauge Included • PD Alarm • 2-Year Warranty The Standard in Filter Backwash Controls 12 or 16 Stations Plus Master Valve Powder Coated Steel Enclosure

Page 22

F12/16 AC/DC/DCL Features and Options STANDARD FEATURES F12/16 AC/DC/DCL NUMBER OF STATIONS PLUS MASTER VALVE 12 or 16 INPUT VOLTAGE 115 VAC 50/60 Hz , or 12-15 VDC OUTPUTS 24 VAC, 12 VDC, or 12 VDC 2-Wire Latching Solenoids PDMU INCLUDED 1-15 PSI MURPHY PD GAUGE ✓ PD DELAY Adjustable SWING OUT,PLUG IN FRONT PANEL ✓ RESETTABLE BACKWASH COUNT ✓ ALARM ✓ ENCLOSURE TYPE Powder-Coated Steel ACTUATION METHOD PERIODIC, MANUAL OR PD ✓ SIMPLE PROGRAMMING ✓ 2 YEAR WARRANTY ✓ OPTIONS SP5 5 WATT SOLAR PANEL Oponal SP5 BRKT MOUNTING BRACKET FOR SP5 Oponal BATT-7 7 AMP-HR BATTERY FOR DCL MODELS Oponal T-230 230 VAC TRANSFORMER Oponal T-115HD HEAVY DUTY 115 VAC TRANSFORMER Oponal T-230HD HEAVY DUTY 230 VAC TRANSFORMER Oponal PDBRKT MOUNTING BRACKET FOR PDMU Oponal DIMENSIONS HEIGHT (in) 9.5 WIDTH (in) 13.0 DEPTH (in) 5.25 SHIPPING WEIGHT (lb) 14

Page 23

Alex-Tronix UNIVERSAL MOUNTING BRACKET Product Overview • Solves all mounting issues with one bracket • Universally mounts all Alex-Tronix filter backwash controller models • Includes mounting bracket and rings designed to attach using user-supplied 3/4” pipe (nominal pipe O.D. 1.050 in) • Mounts Alex-Tronix SPD (Pressure Differential Sensor) • Made of aluminum The Standard in Filter Backwash Controls *pipe not included Pressure Differential Sensor (SPD) Mounts under Bracket Front Back

Page 24

FILTER MASTER SERIES CONTROLLER SELECTION CHART STD FEATURES FM-2DCL FM-4P FM-4/8 FM-4/8UL FM-12/16/32 STATIONS PLUS MASTER VALVE 1 Plus Master Valve or 2 4 4 or 8 4 or 8 12, 16, or 32 INPUT VOLTAGE 4 AA Baeries 115 VAC 50/60 Hz 115 VAC 50/60 Hz 115 VAC 50/60 Hz 115 VAC 50/60 Hz OUTPUT SELECTABLE TO OPERATE 24 VAC, 12 VDC, OR 12 VDC 2-WIRE LATCHING SOLENOIDS 12 VDC 2-Wire Latching Solenoids Only ✓ ✓ ✓ ✓ SELECTABLE STATION SEQUENCE PROGRESSIVE TANK CLEANING ✓ ✓ ✓ ✓ SEQUENTIAL TANK CLEANING ✓ ✓ ✓ ✓ ✓ SPD INCLUDED 1-30 PSI ALEX-TRONIX PD SENSOR Oponal ✓ ✓ ✓ ✓ PD DELAY Adjustable Adjustable Adjustable Adjustable Adjustable SWING OUT, PLUG IN FRONT PANEL Screw-In Panel Screw-In Panel ✓ ✓ ✓ RESETTABLE BACKWASH COUNT ✓ ✓ ✓ ✓ ✓ ALARM FEATURE ✓ ✓ ✓ ENCLOSURE TYPE Rust-Proof Outdoor Rust-Proof Outdoor Meets NEMA 4X Rang Meets NEMA 4X Rang Powder-Coated Steel ACTUATION METHOD PERIODIC, MANUAL, OR PD ✓ ✓ ✓ ✓ ✓ SIMPLE PROGRAMMING ✓ ✓ ✓ ✓ ✓ 2 YEAR WARRANTY ✓ ✓ ✓ ✓ ✓ UL LISTED ✓ EASY RETROFIT FROM F-SERIES F12/16 OPTIONS SPD 1-30 PSI ALEX-TRONIX PD SENSOR Oponal Included Included Included Included SP5 5 WATT SOLAR PANEL Oponal Oponal Oponal Oponal SP5 BRKT MOUNTING BRACKET FOR SP5 Oponal Oponal Oponal Oponal PDMU 1-15 PSI MURPHY PD GAUGE Oponal Oponal Oponal Oponal Oponal PDBRKT MOUNTING BRACKET FOR PDMU Oponal Oponal Oponal Oponal Oponal BATT-7 7 AMP-HOUR BATTERY PACK FOR DCL MODELS Oponal Oponal Oponal Oponal T-115 115 VAC TRANSFORMER Included Included Included Included T-230 230 VAC TRANSFORMER Oponal Oponal Oponal Oponal T-115HD 115 VAC HEAVY DUTY TRANSFORMER Oponal Oponal Oponal Oponal T-230HD 230 VAC HEAVY DUTY TRANSFORMER Oponal Oponal Oponal Oponal

Page 25

F-SERIES CONTROLLER SELECTION CHART STANDARD FEATURES F2 AC/DC-D F3 AC/DC/DCL F4/8 AC/DC/DCL F12/16 AC/DC/DCL NUMBER OF STATIONS PLUS MASTER VALVE 2 3 4 or 8 12 or 16 INPUT VOLTAGE 115 VAC 50/60 Hz , or 12-15 VDC 115 VAC 50/60 Hz , or 12-15 VDC 115 VAC 50/60 Hz , or 12-15 VDC 115 VAC 50/60 Hz , or 12-15 VDC OUTPUTS 24 VAC or 12 VDC Non-Latching Solenoids 24 VAC, 12 VDC, or 12 VDC 2-Wire Latching Solenoids 24 VAC, 12 VDC, or 12 VDC 2-Wire Latching Solenoids 24 VAC, 12 VDC, or 12 VDC 2-Wire Latching Solenoids PDMU INCLUDED 1-15 PSI MURPHY PD GAUGE ✓ ✓ ✓ ✓ PD DELAY Fixed Fixed Adjustable Adjustable SWING OUT,PLUG IN FRONT PANEL Screw-In ✓ ✓ ✓ RESETTABLE BACKWASH COUNT ✓ ✓ ✓ ✓ ALARM ✓ ✓ ✓ ENCLOSURE TYPE Rust-Proof Outdoor Powder-Coated Steel Powder-Coated Steel Powder-Coated Steel ACTUATION METHOD PERIODIC, MANUAL OR PD ✓ ✓ ✓ ✓ SIMPLE PROGRAMMING ✓ ✓ ✓ ✓ 2 YEAR WARRANTY ✓ ✓ ✓ ✓ OPTIONS SP5 5 WATT SOLAR PANEL N/A Oponal Oponal Oponal SP5 BRKT MOUNTING BRACKET FOR SP5 N/A Oponal Oponal Oponal BATT-7 7 AMP-HR BATTERY PACK FOR DCL MODELS N/A Oponal Oponal Oponal T-230 230 VAC TRANSFORMER Oponal Oponal Oponal Oponal T-115HD HEAVY DUTY 115 VAC TRANSFORMER Oponal Oponal Oponal Oponal T-230HD HEAVY DUTY 230 VAC TRANSFORMER Oponal Oponal Oponal Oponal PDBRKT MOUNTING BRACKET FOR PDMU Standard Oponal Oponal Oponal

Page 26

In 1977, Alex-Tronix opened its doors for the farmers of the Central San Joaquin Valley with a mission to save water and energy. We were the first manufacturer to reliably automate agricultural filter backwash systems. Today, OEM (Original Equipment Manufacturers) and dealers sell our controls in every region of the world, so you can find our high quality products wherever you need them. Made in America, we pride ourselves on manufacturing simple to program, reliable controls for your agricultural, industrial, or commercial water filtration needs. With the best service in the industry, Alex-Tronix has set the standard for filter backwash automation, innovation, and customer satisfaction in the world today. About Alex-Tronix Website: alextronix.com Phone: (559) 276-2888 Fax: (559) 276-2890 Toll Free: (888) 224-7630