E Mount Lag QMSE LAG Lag pull out withdrawal capacities lbs in typical lumber Lag Bolt Specifications Specific Gravity 5 16 shaft per 3 thread depth 5 16 shaft per 1 thread depth Douglas Fir Larch 50 798 266 Douglas Fir South 46 705 235 Engelmann Spruce Lodgepole Pine MSR 1650 f higher 46 705 235 Hem Fir 43 636 212 Hem Fir North 46 705 235 Southern Pine 55 921 307 Spruce Pine Fir 42 615 205 Spruce Pine Fir E of 2 million psi and higher grades of MSR and MEL 50 798 266 Sources American Wood Council NDS 2005 Table 11 2 A 11 3 2 A Notes 1 Thread must be embedded in a rafter or other structural roof member 2 See NDS Table 11 5 1C for required edge distances BI 7 2 3 31 Sep 2014 Rev 2
E-Mount Lag QMSE - LAG  Lag pull-out  withdrawal  capacities  lbs  in typical lumber  Lag Bolt Specifications Specific Gra...
E Mount Lag Installation Instructions Installation Tools Required tape measure roofing bar chalk line stud finder caulking gun sealant compatible with roofing materials drill with 7 32 long style bit drill or impact gun with 1 2 socket WARNING Quick Mount PV products are NOT designed for and should NOT be used to anchor fall protection equipment 1 2 3rd course 2nd course 3 1st course Locate choose and mark centers of rafters to be mounted Select the courses of shingles where mounts will be placed 4 Using drill with 7 32 bit drill pilot hole into roof and rafter taking care to drill square to the roof Do not use mount as a drill guide Drill should be long style bit aka aircraft extension bit to drill a 1 deep hole into rafter 7 Carefully lift composition roof shingle with roofing bar just above placement of mount Remove nails as required See Proper Flashing Placement on next page 5 Clean o any sawdust and fill hole with sealant compatible with roofing materials 8 Insert flashing between 1st and 2nd course Slide up so top edge of flashing is at least 3 4 higher than the drip edge of the 3rd course and lower flashing edge is above the drip edge of 1st course Mark center for drilling 6 Slide the flashing into position Insert the rubber plug into the QBlock cavity You are now ready for the rack of your choice Follow all the directions of the rack manufacturer as well as the module manufacturer All roofing manufacturers written instructions must also be followed by anyone modifying a roof system Consult the roof manufacturer s specs and instructions prior to touching the roof Slide the washer and the L foot not included onto the lag screw BI 7 2 3 31 Using a 1 2 inch socket on an impact gun drive the lag screw until the QBlock stops rotating easily DO NOT over torque Sep 2014 Rev 2
E-Mount Lag Installation Instructions Installation Tools Required  tape measure, roofing bar, chalk line, stud finder, cau...
Reference and Tips Additional tips and information for installing mounts nn See Quick Tips videos on nail removal and more at http www quickmountpv com support videos html nn It is not necessary or advisable to use nails or other fasteners to secure the perimeter of the flashing nn The E Mount is made to work with standard and high definition composition asphalt and wood shingle roofs with 5 to 5 5 8 courses If the exposed surface of the course exceeds this measurement you may need to use our Classic Shake Mount instead nn Depending on the season and climate size and location of seal tabs and quality of the shingles the seal tabs that adhere the shingle courses together may not effectively seal the shingles to the flashings If this is the case simply add several quarter sized dabs of manufacturer accepted sealant or asphalt roofing cement meeting ASTM D 4586 Type II between the flashing and the shingle above nn Mounts should not be installed in areas of the roof susceptible to ice damming Water ponding under the shingles can reach the bolt penetration nn Take care not to damage the roofing material while working on the roof Removing stone granules and deforming the shingles in any way can shorten the lifespan of the roofing The value of the solar array is directly affected by the condition of the roof it is attached to BI 7 2 3 31 Sep 2014 Rev 2
Reference and Tips  Additional tips and information for installing mounts  nn  See Quick Tips videos on nail removal, and ...
Conduit Penetration Flashing QMCPC Drawing 1 Drawing 2 Full sized drawing available at quickmountpv com pdfs Conduit Penetration Flashing Drawing pdf BI 7 2 3 22 Feb 2014 Rev 5
Conduit Penetration Flashing QMCPC  Drawing 1  Drawing 2  Full-sized drawing available at  quickmountpv.com pdfs  Conduit-...
Conduit Penetration Flashing Instructions Installation Tools Required tape measure caulking gun roof material EPDM compatible sealants drill with paddle bit hook blade hammer roofing nails WARNING Quick Mount PV products are NOT designed for and should NOT be used to anchor fall protection equipment 1 Mark center of rafter Using the flashing as a template mark the drill point so the flashing reaches up into the 3rd shingle course Drill your conduit hole next to the rafter so you can secure the conduit below the roof surface see Drawing 2 For 1 2 conduit drill 7 8 hole for 3 4 conduit drill 1 hole for 1 conduit drill 1 1 4 hole 4 Slide flashing into place over drilled hole and apply a bead of sealant across the top side of the flashing under the 2nd shingle course Be careful not to rip or tear shingles 7 Apply a bead of sealant compatible with both the roofing material and EPDM rubber to both the flashing and the conduit in the location of the EPDM collar s final position BI 7 2 3 22 3 2 Slide flashing item 1 into position centering the flashing hole with drilled hole Remove any nails that prevent getting the flashing into position Using a hook blade cut shingle around cone to allow correct placement of flashing Flashing should not hang over bottom drip edge of shingle below Apply sealant compatible with the roofing material on the underside of the flashing in an upside down U Under the 3rd course and through the 2nd course secure flashing with 2 roofing nails at the top corners of the flashing at the nail line Apply sealant over nail heads Cut EPDM collar item 2 to appropriate conduit size see Drawing 1 Detail A on reverse Take care to cut a clean level line 5 8 Slide collar over the conduit all the way down to the flashing 6 Your conduit penetration flashing is now complete and ready for additional electrical work Be sure to secure conduit to rafters below the roof surface per local building codes and NEC code requirements Quick Mount PV conduit mounts are also available for roof surface conduit attachments See website for details Helpful hint to see where to apply the sealant slide the collar into place and mark the perimeter with a marker on the flashing and on the conduit then slide the collar up and apply sealant just inside both marks 925 478 8269 www quickmountpv com info quickmountpv com 2700 Mitchell Dr Bldg 2 Walnut Creek CA 94598 Feb 2014 Rev 4 2014 by Quick Mount PV All rights reserved
Conduit Penetration Flashing Instructions Installation Tools Required  tape measure, caulking gun, roof material   EPDM co...
GreenFasten GF1 Product Guide Exploded Product View Bill of Materials Materials Needed for Assembly Item No Description of Material Part Quantity 1 EcoFasten Solar 1 2 L 102 3 Bracket other options available 1 3 5 16 EPDM Bonded 304 18 8 SS Washer 1 4 4 GF 1 Flashing Lag Bolt 5 16 1 3 2 Required Tools 1 877 859 3947 Committed to the Support of Renewable Energy EcoFasten Solar All content protected under copyright All rights reserved 07 24 12 1 1
GreenFasten    GF1     Product Guide  Exploded Product View, Bill of Materials  Materials Needed for Assembly Item No.  De...
Simple Seal Product Guide Exploded Product View Bill of Materials Materials Needed for Assembly Item No Description of Material Part Quantity EcoFasten Solar 1 Simple Seal Bushing 1 2 L 102 3 Bracket other options available 1 3 5 16 EPDM Bonded 304 18 8 SS Washer 1 4 4 Fastener to be determined 1 3 2 Required Tools 1 877 859 3947 Committed to the Support of Renewable Energy EcoFasten Solar All content protected under copyright All rights reserved 07 25 2012 1 1
Simple Seal     Product Guide  Exploded Product View, Bill of Materials  Materials Needed for Assembly Item No.  Descripti...
Solar Seal 900 series is an elastomeric adhesive sealant based on 100 terpolymers Our best sealant formulated for commercial industrial and high end residential applications Available in Clear at Cooper Electric A high performance alternative to silicones and urethanes Field proven since 1977
Solar Seal  900 series, is an elastomeric adhesive sealant based on 100  terpolymers. Our best sealant, formulated for com...
SolarMount PV s most versatile mounting system Ground Mount Solution Roof Mount Solution Google Campus California Open Structure Solution 2007 courtesy of EI Solutions Inc SolarMount is the most versatile PV mounting rail system on the market today We ve engineered installer friendly components for maximum flexibility allowing you to solve virtually any PV mounting challenge The universal SolarMount rail system solutions can be assembled into a wide variety of PV mounting structures to accommodate any job site Unirac provides a technical support system complete with installation and code compliance documentation an on line estimator and design assistance to help you solve the toughest challenges R A HILTI GROUP COMPANY Visit us online at www unirac com
SolarMount      PV   s most versatile mounting system  Ground Mount Solution  Roof Mount Solution  Google Campus, Californ...
SolarMount RAIL OPTIONS PV s most versatile mounting system SolarMount HD HD heavy duty rail adds the SolarMount advantage to U LAs see separate data sheets and custom applications that require long spans Standard SolarMount MODULE MOUNTING Standard rail gives you ultimate exibility including bottom mounting and tilt up options Assembly Sequence Is Your Choice Top Mounting Clamps Bottom Mounting Clips Ideal for ush mount applica Use bottom mounting clips standard and HD rail only whenever you prefer to preassemble the array using module mounting holes Simply fit the clip into its rail slot over the mounting bolt for a secure connection Adjust the clip position anywhere along the rail slot tions such as residential rooftops where it is most convenient to secure footings and rails before installing modules top mounting clamps securely grip any point of the module frame freeing you from the constraints of module mounting holes
SolarMount   RAIL OPTIONS PV   s most versatile mounting system SolarMount   HD HD  heavy duty  rail adds the SolarMount a...
ATTACHMENT OPTIONS Flexible Components Speed Installation Standoffs LH side Use standoffs whenever ashed installations KEY BENEFITS of SolarMount Rail Maximum exibility are required on tile roofs for example Twopiece aluminum standoffs allow precise placement of a ashing over a secured base prior to the installation of the standoff itself Flush high profile or low profile configurations Roof or ground mount All standoff types come in four standard heights 3 4 6 and 7 inches Appropriate ashings are available Pitched or at roof Ease of installation Serrated L feet Standard for ground mount installations on residential and commercial rooftops use L feet alone above asphalt composition shingles or in conjunction with at top standoffs Mount standard or light rails Configure to either of two rail heights one promoting air ow for cooling the other offering close to the roof aesthetics Installer friendly components Minimized penetration with longer attachment spans than competitive products Designed with customer input Grounding and wire management options Strut in Tube Style Legs Quickly set the precise tilt angle required Styles are available for high profile 1 or 2 legs per rail and low profile installations Each series offers three leg lengths so you can adjust to exactly the tilt angle you want up to a maximum of 60 degrees without cutting and drilling at the job site Complete technical support Installation and code compliance documentation Online estimator Person to person customer service FastFoot The FastFoot attachment features Eco Fasten technology by the Alpine Snow Guard Company allowing attachments to metal concrete and wood decks without compromising the integrity of the roof Core component for Unirac mounting solutions RH column Two rail options to accommodate any job site Incorporated into other major product lines Tile Hook Made from cast aluminum the tile hook attachment provides SolarMount with a cost effective solution for barrel or Spanish tile roofs All required lag bolts and hardware are included Refer to the tile hook engineering data for max load capabilities R A HILTI GROUP COMPANY
ATTACHMENT OPTIONS Flexible Components Speed Installation Standoffs  LH side  Use standoffs whenever    ashed installation...
Bright Thinking in Solar Ground Mounted Solution Roof Mounted Solution Open Structure Solution Google Campus California 2007 courtesy of EI Solutions Inc Component Specifications Code Compliant 6105 T5 aluminum extrusion The SolarMount system is PE certified Call Unirac for documentation applicable to your building code SolarMount rails Mounting clips and clamps Tilt legs and L feet Warranty Two piece standoffs SolarMount is covered by a 10 year limited product warranty and a 5 year limited finish warranty Severe Condition 4 very severe zinc plated welded steel One piece standoffs For complete warranties download any SolarMount installation manual from our web site 18 8 stainless steel Fasteners R A HILTI GROUP COMPANY Visit us online at www unirac com
Bright Thinking in Solar  Ground Mounted Solution  Roof Mounted Solution  Open Structure Solution  Google Campus, Californ...
RM SPECIFICATIONS PROJECT CHARACTERISTICS Allowable Roof Slope 5 Degrees Unevenness 3 5 Degrees Max Building Height 100 ft Wind Speed Up to 120 mph Wind Exposure Categories B and C D upon request PSF on Roof As low as 3 5 PSF Surfaces Most common roof types including PVC 1 2 3 TPO membranes bitumen concrete Min Local Contact Area THE POWER OF SIMPLICITY 38 in per module 57 in with roof pad Module Orientation Landscape Nominal Module Tilt Angle 10 Degrees nominal Row Spacing 18 in nominal 4 4 COMPONENTS MATERIALS Introducing the Unirac RM An easy to assemble high quality low part number flat roof solution from the industry s leading PV mounting manufacturer Ballast Bay Aluminum 6063 T5 Module Clamp Aluminum 6005A T61 Locking 3 8 Hex Bolt Stainless Steel 300 Series Roof Pad TPE 70 Shore A The smart design and engineering Width 21 in of the Unirac RM is the result of Length 17 in years of proven performance as Height 13 in Weight 3 5 lbs Roof Pad 3 in x 10 in the industry s leading PV mounting company Assembled from 2 parts with 1 tool Unirac delivers the easiest to install and most reliable flat roof solution on the market today designed to reduce overall project costs risks and complexity BALLAST BAY GEOMETRY MODULE COMPATIBILITY Standard 60 and 72 Cell Framed Modules Module Clamp w Integrated Bonding to UL2703 If required Cable Management www unirac com Seismic Attachment Compatible w strut accessories WARRANTY 10 Year Structural Performance Warranty 20 Year Materials and Defects Warranty R Copyright 2012 2013 Unirac Inc All rights reserved Pub130821 1 Self configurable up to 60 Greater than 60 upon request 2 ASCE 7 05 Wind Maps 3 Criteria used ASCE 7 10 wind 110 mph Snow 0 Building height 30 ft Exposure Category B 4 Varies by module
RM  SPECIFICATIONS  PROJECT CHARACTERISTICS Allowable Roof Slope     5 Degrees  Unevenness       - 3.5 Degrees  Max Buildi...
SM SOLAR MOUNT NEW ENHANCEMENTS SOLARMOUNT defined the standard in solar racking New enhancements are designed to get installers off the roof faster than ever before Components are pre assembled and optimized to reduce installation steps and save labor time Our new grounding bonding process eliminates copper wire and grounding straps to reduce costs Utilize the microinverter mount with a wire management clip for an easier installation ELIMINATE THE GROUNDWIRE FROM YOUR SOLARMOUNT ARRAY INTEGRATED GROUNDING POWERED BY LOSE THE COPPER LUGS UL2703 UL2703D L I S T E UL2703 GET OFF THE ROOF FASTER THAN EVER BEFORE UL2703D L I S T E BONDING GROUNDING SYSTEM FIRE CLASSIFICATION CLASS A TYPE 1 2 3 MODULES BONDING GROUNDING MECHANICAL LOADING SYSTEM FIRE CLASSIFICATION CLASS A TYPE 1 2 3 10 MODULES SYSTEM FIRE CLASSIFICATION CLASS A TYPE 1 2 3 MODULES ROOF MOUNT S Y S T EMS BONDING GROUNDING MECHANICAL LOADING OPTIMIZED CLASSIFICATION SYSTEM FIRE COMPONENTS CLASS A TYPE 1 2 3 MODULES VERSATILITY AVAILABILITY DESIGN TOOLS
SM  SOLAR MOUNT  NEW ENHANCEMENTS  SOLARMOUNT defined the standard in solar racking. New enhancements are designed to get ...
SM SOLAR MOUNT R NEW ENHANCEMENTS OPTIMIZED COMPONENTS INTEGRATED BONDING PRE ASSEMBLED PARTS Components are pre assembled and optimized to reduce installation steps and save labor time Our new grounding bonding process eliminates copper wire and grounding straps or bonding jumpers to reduce costs Utilize the microinverter mount with a wire management clip for an easier installation INTEGRATED BONDING MIDCLAMP VERSATILITY ONE PRODUCT MANY APPLICATIONS Quickly set modules flush to the roof or at a desired tilt angle Change module orientation to portrait or landscape while securing a large variety of framed modules on flat low sloped or steep pitched roofs Available in mill clear and dark anodized finishes to outperform your projects financial and aesthetic aspirations INTEGRATED BONDING SPLICE BAR AVAILABILITY NATIONWIDE NETWORK Unirac maintains the largest network of stocking distributors for our racking solutions Our partners have distinguished their level of customer support availability and overall value thereby providing the highest level of service to users of Unirac products Count on our partners for fast and accurate delivery to meet your project objectives Visit Unirac com for a list of distributors AUTOMATED DESIGN TOOL DESIGN PLATFORM AT YOUR SERVICE Creating a bill of materials is just a few clicks away with U Builder a powerful online tool that streamlines the process of designing a code compliant solar mounting system Save time by creating a user profile and recall preferences and projects automatically when you log in You will enjoy the ability to share projects with customers there s no need to print results and send to a distributor just click and share INTEGRATED BONDING L FOOT w T BOLT INTEGRATED BONDING MICROINVERTER MOUNT w WIRE MANAGEMENT UNIRAC CUSTOMER SERVICE MEANS THE HIGHEST LEVEL OF PRODUCT SUPPORT UNMATCHED EXPERIENCE CERTIFIED QUALITY ENGINEERING EXCELLENCE BANKABLE WARRANTY DESIGN TOOLS PERMIT DOCUMENTATION TECHNICAL SUPPORT CERTIFIED QUALITY PROVIDER BANKABLE WARRANTY Unirac s technical support team is dedicated to answering questions addressing issues in real time An online library of documents including engineering reports stamped letters and technical data sheets greatly simplifies your permitting and project planning process Unirac is the only PV mounting vendor with ISO certifications for 9001 2008 14001 2004 and OHSAS 18001 2007 which means we deliver the highest standards for fit form and function These certifications demonstrate our excellence and commitment to first class business practices As a Hilti Group Company Unirac has the financial strength to back our products and reduce your risk Have peace of mind knowing you are receiving products of exceptional quality SOLARMOUNT is covered by a 10 year limited product warranty and a 5 year limited finish warranty PROTECT YOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLENCE AND A SUPERIOR SUPPLY CHAIN PUB 150101 DIGITAL UPDATES
SM  SOLAR MOUNT  R  NEW ENHANCEMENTS  OPTIMIZED COMPONENTS  INTEGRATED BONDING   PRE-ASSEMBLED PARTS Components are pre-as...
POWER RAILTM P6 Light Weight PV Mounting System Catalog Quality Hardware for the PV Industry
POWER RAILTM P6 Light Weight PV Mounting System Catalog  Quality Hardware for the PV Industry
POWER RAIL P6 Module Mounting System Lightweight PV module mounting system engineered to reduce installation costs and provide maximum strength for parallel to roof or tilt up mounting applications The Power Rail P6 top clamping mounting system is designed with the professional PV solar installer in mind The lightweight rail utilizes a single tool with a revolutionary RADTM Fastener for faster bolt placement The unique shape of the RAD provides an anti rotation feature locking the bolt in the proper orientation when installed The high strength rigid rail also includes an integral wiring channel for securing cables and providing a professional finish The system includes all of the mounting options from the Power Rail family designed for secure and water tight attachments to any roof style Features Flexible Mounting Options High Strength Reliable Design n Engineered rail profile for maximum strength to weight ratio n Structural Aluminum rigid rail construction Height adjustable L mounting feet n n Tilt Feet up to 10 degrees n Solid Aluminum Power Post stanchions n High Strength stainless steel module clamps and hardware n Easy Feet attachment anywhere on metal or composite roof decking Reduced Installation Time and Costs n PV Flashing hardware n Single Tool Assembly all 5 16 hardware n RAD Fastener for quick bolt placements n Integral Wiring Channel for securing cables n Standard lengths up to 27 feet eliminate costly rail splices n Snap In WEEB Integral module grounding option Wind Loading P6 Rail Span and Cantilever Distances inches WIND SPEED MPH SPAN C VER SNOW LOAD PSF 0 10 20 30 40 50 60 70 80 90 100 90C 72 36 60 32 54 26 48 24 43 21 40 20 36 18 33 16 31 15 29 14 28 14 100C 60 32 58 28 48 24 46 23 42 21 38 19 36 18 33 16 31 15 29 14 28 14 110C 58 28 54 26 48 24 44 22 40 20 37 18 35 17 33 16 31 15 29 14 28 14 120C 54 26 54 26 46 23 42 21 39 19 36 18 34 17 32 16 31 15 29 14 28 14 130C 48 24 48 24 44 22 40 20 37 18 35 17 33 16 32 16 30 15 29 14 28 14 Please refer to design guidelines and ASCE requirements for more information 2
POWER RAIL    P6 Module Mounting System Lightweight PV module mounting system engineered to reduce installation costs and ...
Power Rail P6 Extrusion Power Rail P6 is an engineered profile extrusion made from Series 6000 structural aluminum Standard finish is mill finish aluminum Power Rail P6 Extrusion Standard Lengths Part P6 84 P6 126 P6 162 P6 204 P6 240 P6 282 P6 324 Length 84 126 162 204 240 282 324 Weight Per Unit lbs 5 7 5 9 5 12 14 16 5 19 120 00 116 00 111 00 107 00 103 00 98 00 139 00 134 00 129 00 124 00 119 00 114 00 158 00 152 00 146 00 140 00 135 00 129 00 Pricing per Quantities Higher Volume Discount Available 1 19 44 00 65 00 83 00 103 00 20 39 42 00 63 00 80 00 99 00 40 59 41 00 60 00 77 00 96 00 60 79 40 00 59 00 74 00 92 00 80 99 38 00 56 00 72 00 88 00 100 36 00 54 00 68 00 85 00 Splice Plates Part Description P6 SPK Splice Plate Quantity 1 9 10 Weight Per Unit lbs 0 40 Price 7 00 6 50 Tilted L Feet Part P6 FF5 P6 BF5 P6 FF10 P6 BF10 Description Quantity 1 49 5 Front Foot 50 99 100 1 49 5 Back Foot 50 99 100 1 49 10 Front Foot 50 99 100 1 49 10 Back Foot 50 99 100 Weight Per Unit lbs 0 25 0 50 0 25 0 75 Price 8 00 7 50 7 00 12 00 11 50 11 00 8 00 7 50 7 00 16 00 15 50 15 00 3
Power Rail    P6 Extrusion Power Rail P6 is an engineered profile extrusion made from Series 6000 structural aluminum. Sta...
Module Clamps Module Clamps are Type 304 stainless steel for higher yield strength and durability The low profile design and slim 3 8 gap between modules provide a professional appearance and higher density RAD Hardware Part EC MC RAD RAD Description Module End Clamp w RAD Hardware Module Mid Clamp w RAD Hardware Quantity 1 19 20 39 40 59 60 79 80 99 100 1 49 50 99 Weight Per Unit lbs 0 15 0 08 100 Price 6 50 6 05 5 85 5 65 5 45 5 25 5 75 5 00 Mid Clamp w RAD Bolt End Clamp w RAD Bolt 4 50 Note Replace xxx with module series from the Solar Module Chart starting on page 11 Example EC SWD32 end clamps for Solar World 155 165 175 modules Add B suffix to part number for black powder coat Example EC SWD32 RAD B Add 25 to price Carriage Bolt Hardware Part Description Module End Clamp w Carriage Bolt Hardware EC CAR MC Module Mid Clamp CAR w Carriage Bolt Hardware Quantity 1 19 20 39 40 59 60 79 80 99 100 1 49 50 99 Weight Per Unit lbs 0 15 0 08 100 Price 5 25 5 05 4 85 4 65 4 45 4 25 4 50 3 75 3 25 Note Replace xxx with module series from the Solar Module Chart starting on page 11 Example EC SWD32 end clamps for Solar World 155 165 175 modules Add B suffix to part number for black powder coat Example EC SWD32 RAD B Add 25 to price Universal End Clamp Part Quantity Universal End Clamp w Set Bolt Weight Per Unit lbs 1 49 P6 ECU 4 Description Price 9 00 0 15 50 99 100 8 50 8 00 End Clamp w Carriage Bolt Mid Clamp w Carriage Bolt
Module Clamps Module Clamps are Type 304 stainless steel for higher yield strength and durability. The low profile design ...
L Feet L Feet are fabricated from high strength 3 16 aluminum and include a vertical slot for adjusting to irregular surfaces Part Description P6 LF2 Standard 2 5 L Mounting Foot P6 LF5 Tall 5 L Mounting Foot P6 PPB Power Post Bracket Quantity Weight Per Unit lbs 1 49 50 99 100 1 49 50 99 100 1 49 50 99 100 0 24 0 40 09 Price 7 00 6 50 6 00 10 00 9 25 8 50 6 50 6 00 5 50 L Style Foot w Carriage Bolt Power Post Bracket w Carriage Bolt Easy Feet Easy Feet mount directly to metal and composite shingles or other roofing materials and do not require attachment to a roof structural member Sealing butyl mastic backing and RoofGrip screws are included Part P6 PEF Description Quantity Pivot Easy Mounting Foot 1 49 50 99 100 Weight Per Unit lbs 0 76 Price 21 50 20 50 19 00 RoofGrip is a trademark of ITW Buildex and Illinois Toolworks Inc 5
    L    Feet    L    Feet are fabricated from high strength 3 16  aluminum and include a vertical slot for adjusting to i...
Corrugated Roof Mounts Part Description CMB Mounting Bridge to Span Peaks of Corrugated Metal Roofs Quantity 1 49 50 99 Price 13 50 12 50 100 11 00 Note Not all corrugated metal roofs are the same Please contact shop to design mounting bridges that are specific to your application Pricing subject to change L Foot not included Roof Rod Mount Roof Rod mounts attach directly to the roof deck and are suitable for tile and other roofing materials Sealing butyl mastic backing and RoofGrip screws included Part Description Quantity Weight Per Unit lbs Price P6 RRM Threaded Rod Mount 1 49 50 99 100 1 5 30 00 29 00 27 50 Note L Foot included RoofGrip is a trademark of ITW Buildex and Illinois Toolworks Inc 6
Corrugated Roof Mounts Part    Description  CMB  Mounting Bridge to Span Peaks of Corrugated Metal Roofs  Quantity 1-49 50...
Power Post Stanchions Power posts offer high strength solid aluminum construction and are used with flashing cones Part P6 PP4 P6 PP6 Description 4 Power Post 6 Power Post Weight Per Unit lbs Diameter Quantity 1 31 1 49 50 99 100 0 67 1 31 1 49 50 99 100 0 94 Price 21 00 20 00 18 50 22 00 21 00 19 50 Super Post Stanchions Super posts offer high strength solid aluminum construction for larger arrays and higher roof clearance Part Description Weight Per Unit lbs Diameter Quantity 2 6 3 2 P6 SP8 8 Super Mounting Post 1 75 1 49 50 99 100 P6 SP10 10 Super Mounting Post 1 75 1 49 50 99 100 Price 42 00 39 00 36 00 45 00 42 00 39 00 7
Power Post    Stanchions Power posts offer high strength solid aluminum construction and are used with flashing cones.  Pa...
Easy Power Post Stanchions Part Description Diameter P6 EP4 4 Easy Post 1 31 P6 EP6 6 Easy Post 1 31 Quantity 1 49 50 99 100 1 49 50 99 100 Weight Per Unit lbs 0 94 1 21 Price 25 50 24 50 23 00 26 50 25 50 24 00 Offset Power Post Stanchions Offset Power Posts center the flashing cone and avoid potential gaps with the Power Post base Part Description Diameter Quantity P6 OP4 4 Offset Mounting Post 1 31 50 99 P6 OP6 8 6 Offset Mounting Post Weight Per Unit lbs 1 49 Price 21 00 0 67 20 00 100 1 49 1 31 18 50 22 00 50 99 100 0 94 21 00 19 50
Easy Power Post    Stanchions Part    Description  Diameter  P6-EP4  4  Easy Post  1.31   P6-EP6  6  Easy Post  1.31   Qua...
Power Rail Accessories Power Rail accessories are non discountable products Power Rail PV Flash Power Rail PV Flash includes one universal slotted compression block one 5 16 x 5 hangerbolt and one 8 x 12 flashing in matte black color Part PFU Mounting Foot Qty Universal Compression Block 1 49 50 99 100 Shipping Weight Per Unit 0 80 lbs Price 14 00 13 00 11 50 Power Post Flashing Part Description OF Oatey Flashing with Rubber Boot for 1 31 posts Quantity 1 11 12 47 Weight Per Unit lbs 0 66 Price 5 15 4 40 SMF 3 90 1 11 Aluminum One Piece Flashing 48 10 40 11 47 1 15 8 90 48 RFC 7 85 1 11 Rubber Flashing Collar Flashing with Rubber Boot 2 00 11 47 48 0 05 1 75 1 55 Rubber Flashing Collar for use with solid metal flashing NOTE Oatey No Calk NC 1 Solar flashing are galvanized with a UV Rubber Boot that fits onto the Power Post Oatey flashing may be used on roofs with 0 45 degree angles No Calk is a registered trademark of Oatey Co 9
Power Rail    Accessories  Power Rail accessories are non-discountable products  Power Rail    PV Flash Power Rail PV Flas...
Power Rail Accessories Power Rail accessories are non discountable products Flat Roof Flashing Part Description Quantity Weight Solid Metal Per Unit Flashing lbs Price 1 11 LPK4 4 Lockin Pocket 12 47 14 50 1 7 13 50 48 12 75 1 11 21 75 LPK6 6 Lockin Pocket 12 47 2 6 HFUS Hurricane Force Universal Sealer 1 25 75 BPAG Battery Powered Applicator Gun 1 Lockin Pocket 625 00 48 20 75 19 00 WEEB DPF Module Grounding Clip Grounding Hardware Part Description Quantity Weight Per Unit lbs 10 99 WEEB DPF Module Grounding Clip 100 999 003 100 999 1 50 003 1000 WEEBL 8 0 WEEB 8 0 RBJ 10 99 Rail Grounding Lug 100 10 99 Rail Bonding Jumper 100 ACME PV Cable Clip 100 999 1 10 0 19 0 11 5 65 4 65 6 45 52 0 006 41 33 10 99 ACME 2 Cable Clip 52 100 999 1000 WEEB 11 5 7 80 1000 ACC WEEB Lug Assembly 90 10 99 ACC PV 1 10 90 10 99 Splice Plate Grounding Clip Price 1 50 1000 WEEB 11 5 NOTE Lockin Pockets and Hurricane Force Sealer are backed by a third party warranty on all flat roof penetrations 0 006 Rail Grounding Lug 41 33 Note Cable Clips snugly hold 1 or 2 designated cables Rail Bonding Jumper ACME Cable Clip 10
Power Rail    Accessories  Power Rail accessories are non-discountable products  Flat Roof Flashing Part    Description  Q...
Solar Module Chart AEE Power Fab Module Series AEE21 ALEO ALE33 ALE39 ALPS ALE32 ALP39 BP SOLAR BP33 BP31 BP27 CSI CSI39 DAY4 BP21 DAY39 EVERGREEN EVR26 EVR38 EVR38X Manufacturer s Modules AE80HE of Supports Rail Length inches Kit Weight lbs ALE170 S16 165 185 of Supports Rail Length inches Kit Weight lbs ALE210 S18 210 230 of Supports Rail Length inches Kit Weight lbs ALE S3 155 175 of Supports Rail Length inches Kit Weight lbs ALPS2000 of Supports Rail Length inches Kit Weight lbs SX3200 SX3195 SX3190 of Supports Rail Length inches Kit Weight lbs BP4175 BP175B BP4175I SX170B SX160B BP3160 of Supports Rail Length inches Kit Weight lbs SX3140 SX3130 BP3135 BP3130 BP3125 BP3115 BP3110 of Supports Rail Length inches Kit Weight lbs BP380 BP375 BP350 BP340 of Supports Rail Length inches Kit Weight lbs CS6P 170 180 190 of Supports Rail Length inches Kit Weight lbs 48MC 170 of Supports Rail Length inches Kit Weight lbs EC120 of Supports Rail Length inches Kit Weight lbs ES190 of Supports Rail Length inches Kit Weight lbs ES A 200 of Supports Rail Length inches Kit Weight lbs 2 3 Number of Modules 4 5 6 4 45 18 4 66 23 4 87 28 4 108 33 4 69 24 4 102 32 4 135 39 4 81 27 4 121 36 4 66 23 7 8 4 129 38 6 151 47 6 172 52 6 168 51 6 201 59 8 234 71 8 267 78 6 160 49 6 200 59 8 239 72 8 278 81 10 318 94 4 98 31 4 130 38 6 162 50 6 194 57 8 226 69 8 258 76 4 81 27 4 121 36 6 160 49 6 200 59 8 239 72 8 278 81 10 318 94 4 69 24 4 103 32 4 136 40 6 169 51 6 203 59 8 236 71 8 269 79 4 66 23 4 97 31 4 129 38 6 160 49 6 191 57 6 223 64 8 254 75 4 56 21 4 83 27 4 110 34 4 137 40 6 164 50 6 191 57 6 218 63 4 46 19 4 67 24 4 89 29 4 110 34 4 131 39 6 153 48 6 174 53 4 81 27 4 120 36 6 159 49 6 198 58 8 237 71 8 276 80 10 315 93 4 81 27 4 121 36 6 160 49 6 200 59 8 239 72 8 278 81 10 318 94 4 55 21 4 81 27 4 107 33 4 133 39 6 159 49 6 185 55 6 211 61 4 78 26 4 116 35 6 154 48 6 192 57 8 230 70 8 268 78 10 306 91 4 78 26 4 116 35 6 154 48 6 192 57 8 230 70 8 268 78 10 306 91 continued on next page 11
Solar Module Chart AEE  Power-Fab   Module Series AEE21  ALEO  ALE33  ALE39  ALPS  ALE32  ALP39  BP SOLAR  BP33  BP31  BP2...
Solar Module Chart continued Power Fab Module Series GE GE21 GE26 GLOBAL SOLAR GE39 GSE47 ISOFOTON ISO42 ISO31 ISO22 KANEKA KNK38 KNK38X KNK39 KYOCERA KYO39 KYO27 KYO26 Manufacturer s Modules GE85 of Supports Rail Length inches Kit Weight lbs GE110 of Supports Rail Length inches Kit Weight lbs GE173 GEPVp 185 MC GEPVp 200 MC of Supports Rail Length inches Kit Weight lbs 33060 O of Supports Rail Length inches Kit Weight lbs IS 200 32 IS 150S 24 IS 150S 12 of Supports Rail Length inches Kit Weight lbs IS 150 32 IS 150 24 IS 150 12 of Supports Rail Length inches Kit Weight lbs IS 75 12 of Supports Rail Length inches Kit Weight lbs KNK G S A060 P LE055 of Supports Rail Length inches Kit Weight lbs KNK ED SD120 of Supports Rail Length inches Kit Weight lbs KNK SC EC120 of Supports Rail Length inches Kit Weight lbs KD210 KD205 KD180GX LP KC200 KC175 of Supports Rail Length inches Kit Weight lbs KD135GX LP KD130GX LP of Supports Rail Length inches Kit Weight lbs KC130 KC85T KC65T KC50T KC40T of Supports Rail Length inches Kit Weight lbs 2 3 Number of Modules 4 5 6 4 45 18 4 66 23 4 87 28 4 109 33 4 55 21 4 82 27 4 108 33 4 81 27 4 120 36 4 96 30 7 8 4 130 38 6 151 47 6 172 52 4 135 39 6 161 50 6 187 56 6 214 62 6 159 49 6 198 58 8 236 71 8 275 80 10 314 93 4 143 41 6 190 56 8 237 71 8 284 82 10 331 97 10 378 108 4 86 28 4 127 38 6 169 51 6 211 61 8 252 75 8 294 85 10 335 98 4 66 23 4 97 31 4 129 38 6 160 49 6 191 57 6 223 64 8 254 75 4 46 19 4 68 24 4 90 29 4 112 34 4 134 39 6 156 48 6 178 53 4 79 26 4 117 35 6 155 48 6 194 57 8 232 70 8 270 79 10 308 92 4 79 26 4 117 35 6 155 48 6 194 57 8 232 70 8 270 79 10 308 92 4 81 27 4 121 36 6 160 49 6 200 59 8 239 72 8 278 81 10 318 94 4 81 27 4 121 36 6 160 49 6 200 59 8 239 72 8 278 81 10 318 94 4 56 21 4 83 27 4 109 34 4 136 40 6 163 50 6 189 56 6 216 62 4 55 21 4 81 27 4 107 33 4 133 39 6 159 49 6 185 55 6 211 61 continued on next page 12
Solar Module Chart  continued  Power-Fab   Module Series  GE  GE21  GE26  GLOBAL SOLAR  GE39  GSE47  ISOFOTON  ISO42  ISO3...
Solar Module Chart continued Power Fab Module Series MITSUBISHI MIT26 MIT32 MIT27 NINGBO NIN32 REC MIT33 REC39 SANYO SAN32 SAN35 SCHOTT ASE51 SCHUCO SAN36 SCH32 SHP21 SHARP SHP26 SHP33 SOLARWORLD SHP39 SWD21 SWD40 Number of Modules Manufacturer s Modules 2 3 4 5 6 MF110 of Supports 4 4 4 4 6 Rail Length inches 54 80 106 132 157 Kit Weight lbs 21 27 33 39 49 MF125 MT165 EB3 of Supports 4 4 4 6 6 Rail Length inches 67 99 131 163 194 Kit Weight lbs 24 31 38 50 57 UE125 of Supports 4 4 4 4 6 Rail Length inches 56 83 110 137 164 Kit Weight lbs 21 27 34 40 50 MT180 UD4 of Supports 4 4 4 6 6 Rail Length inches 69 102 136 169 202 Kit Weight lbs 24 32 40 51 59 TDB125 125 72 P of Supports 4 4 4 6 6 Rail Length inches 67 99 131 164 196 Kit Weight lbs 24 31 39 50 58 SCM210 of Supports 4 4 6 6 8 Rail Length inches 81 121 160 200 239 Kit Weight lbs 27 36 49 59 72 HIT POWER 205N 210N 215N of Supports 4 4 6 6 6 Rail Length inches 67 99 131 164 196 Kit Weight lbs 24 31 39 50 58 HIT POWER 190 195 200 BA19 of Supports 4 4 6 6 6 Rail Length inches 73 108 143 178 213 Kit Weight lbs 25 34 46 54 62 HIP200BA3 of Supports 4 4 6 6 6 Rail Length inches 74 109 145 181 216 Kit Weight lbs 25 34 46 54 63 ASE300 of Supports 4 6 6 8 10 Rail Length inches 104 155 206 257 308 Kit Weight lbs 32 48 60 76 92 S125 SP S158 SP S165 SP of Supports 4 4 4 6 6 Rail Length inches 67 99 131 163 195 Kit Weight lbs 24 31 38 50 57 NE 80EJEA NE 80U1 of Supports 4 4 4 4 4 Rail Length inches 46 67 89 110 132 Kit Weight lbs 19 24 29 34 39 ND 123U1 ND L3EJEA ND L5E1U ND 130UJF of Supports 4 4 4 4 6 Rail Length inches 55 82 108 135 161 Kit Weight lbs 21 27 33 39 50 NE 170U1 NT 175 U1 NE 165U1 NT 180U1 of Supports 4 4 4 6 6 Rail Length inches 68 101 134 167 200 Kit Weight lbs 24 32 39 51 59 ND 200U1F ND 205U1F ND 208U1 ND 216 U1F ND 220U1F ND 220U2 ND 224U1 ND 224U2 ND 167U3 of Supports 4 4 6 6 8 Rail Length inches 82 121 161 200 239 Kit Weight lbs 27 36 49 59 72 SQ 80 SW75 SW80 of Supports 4 4 4 4 4 Rail Length inches 45 66 87 109 130 Kit Weight lbs 18 23 28 33 38 SW220 230 235 240 of Supports 4 4 6 6 8 Rail Length inches 83 122 162 202 241 Kit Weight lbs 27 36 49 59 72 7 8 6 183 55 6 209 61 8 226 69 8 258 76 6 191 57 6 218 63 8 235 71 8 268 79 8 228 69 8 260 77 8 278 81 10 318 94 8 228 69 8 260 77 8 248 75 8 283 83 8 252 75 8 287 83 10 359 104 12 410 120 8 227 69 8 259 76 6 153 48 6 175 53 6 188 56 6 214 62 8 233 70 8 266 78 8 279 81 10 318 94 6 151 47 6 172 52 8 201 81 10 321 94 continued on next page 13
Solar Module Chart  continued  Power-Fab   Module Series  MITSUBISHI  MIT26  MIT32  MIT27  NINGBO  NIN32  REC  MIT33  REC3...
Solar Module Chart continued Power Fab Module Series SUNPOWER SPR21 SPR32 SPR42 SUNTECH STP32 STP39 STP39X SWZ23 SUNWIZE SWZ20 SWZ24 SWZ23X SWZ26 UNI SOLAR SWZ32 UNI30 UNI32 YINGLI YNG39 YNG41 14 Manufacturer s Modules SPR 90 of Supports Rail Length inches Kit Weight lbs SPR 220 of Supports Rail Length inches Kit Weight lbs SPR 315 of Supports Rail Length inches Kit Weight lbs STP170 175 180 of Supports Rail Length inches Kit Weight lbs STP200 of Supports Rail Length inches Kit Weight lbs STP260 270 280 of Supports Rail Length inches Kit Weight lbs SWZ 50A of Supports Rail Length inches Kit Weight lbs SWZ60 of Supports Rail Length inches Kit Weight lbs SW75A SW80A of Supports Rail Length inches Kit Weight lbs SWZ90 of Supports Rail Length inches Kit Weight lbs SWZ120 of Supports Rail Length inches Kit Weight lbs SW170 L SW175 L and SW180 L of Supports Rail Length inches Kit Weight lbs US64 of Supports Rail Length inches Kit Weight lbs ES 62T of Supports Rail Length inches Kit Weight lbs YL175 YL170 YL165 YL160 YL155 YL150 of Supports Rail Length inches Kit Weight lbs YL240 through YL205 of Supports Rail Length inches Kit Weight lbs 2 3 Number of Modules 4 5 6 4 45 18 4 66 23 4 87 28 4 108 33 4 66 23 4 98 31 4 130 38 4 86 28 4 127 38 4 67 24 7 8 4 129 38 6 151 47 6 172 52 6 162 50 6 193 57 8 225 69 8 257 76 6 169 51 6 210 61 8 252 75 8 294 84 10 335 98 4 99 31 4 131 39 6 164 50 6 196 58 8 228 69 8 260 77 4 82 27 4 121 36 6 161 49 6 200 59 8 239 72 8 279 81 10 318 94 4 82 27 4 121 36 6 161 49 6 200 59 8 239 72 8 279 81 10 318 94 4 49 19 4 72 25 4 95 30 4 118 35 4 140 41 6 163 50 6 186 55 4 43 18 4 63 23 4 83 27 4 103 32 4 123 37 4 143 41 6 163 50 4 50 20 4 73 25 4 97 31 4 121 36 6 144 46 6 168 51 6 191 57 4 49 19 4 72 25 4 95 30 4 118 35 4 140 41 6 163 50 6 186 55 4 54 21 4 80 27 4 106 33 4 132 39 6 157 49 6 183 55 6 209 61 4 67 24 4 99 31 4 131 39 6 164 50 6 196 58 8 228 69 8 260 77 4 62 22 4 91 29 4 121 36 6 150 47 6 180 54 6 210 61 8 239 72 4 66 23 4 98 31 4 129 38 6 161 50 6 192 57 8 224 68 8 256 76 4 81 27 4 121 36 6 160 49 6 200 59 8 239 72 8 278 81 10 318 94 4 85 28 4 126 37 6 167 51 6 208 60 8 248 74 8 289 84 10 330 97
Solar Module Chart  continued  Power-Fab   Module Series  SUNPOWER  SPR21  SPR32  SPR42  SUNTECH  STP32  STP39  STP39X  SW...
Enphase Microinverters Enphase M215 The Enphase M215 Microinverter with integrated ground delivers increased energy harvest and reduces design and installation complexity with its all AC approach With the advanced M215 the DC circuit is isolated and insulated from ground so no Ground Electrode Conductor GEC is required for the microinverter This further simplifies installation enhances safety and saves on labor and materials costs The Enphase M215 integrates seamlessly with the Engage Cable the Envoy Communications GatewayTM and Enlighten Enphase s monitoring and analysis software PRODUCTIVE Maximizes energy production Minimizes impact of shading dust and debris No single point of system failure SIMPLE No GEC needed for microinverter No DC design or string calculation required Easy installation with Engage Cable RELIABLE More than 1 million hours of testing and millions of units shipped Industry leading warranty up to 25 years
Enphase   Microinverters  Enphase M215     The Enphase   M215 Microinverter with integrated ground delivers increased ener...
Enphase M215 Microinverter DATA INPUT DATA DC M215 60 2LL S22 IG S23 IG S24 IG Recommended input power STC 190 270 W Maximum input DC voltage 48 V Peak power tracking voltage 27 V 39 V Operating range 16 V 48 V Min Max start voltage 22 V 48 V Max DC short circuit current 15 A Max input current 10 A OUTPUT DATA AC 208 VAC 240 VAC Peak output power 225 W 225 W Rated continuous output power 215 W 215 W Nominal output current 1 1 A A rms at nominal duration 0 9 A A rms at nominal duration Nominal voltage range 208 V 183 229 V 240 V 211 264 V Nominal frequency range 60 0 57 61 Hz 60 0 57 61 Hz Extended frequency range 57 62 5 Hz 57 62 5 Hz Power factor 0 95 0 95 Maximum units per 20 A branch circuit 25 three phase 17 single phase Maximum output fault current 850 mA rms for 6 cycles 850 mA rms for 6 cycles EFFICIENCY CEC weighted efficiency 240 VAC 96 5 CEC weighted efficiency 208 VAC 96 5 Peak inverter efficiency 96 5 Static MPPT efficiency weighted reference EN50530 99 4 Night time power consumption 65 mW max MECHANICAL DATA Ambient temperature range 40 C to 65 C Dimensions WxHxD 171 mm x 173 mm x 30 mm without mounting bracket Weight 1 6 kg 3 4 lbs Cooling Natural convection No fans Enclosure environmental rating Outdoor NEMA 6 FEATURES Compatibility Compatible with 60 cell PV modules Communication Power line Integrated ground The DC circuit meets the requirements for ungrounded PV arrays in NEC 690 35 Equipment ground is provided in the Engage Cable No additional GEC or ground is required Ground fault protection GFP is integrated into the microinverter Monitoring Enlighten Manager and MyEnlighten monitoring options Compliance UL1741 IEEE1547 FCC Part 15 Class B CAN CSA C22 2 NO 0 M91 0 4 04 and 107 1 01 Frequency ranges can be extended beyond nominal if required by the utility To learn more about Enphase Microinverter technology visit enphase com 2014 Enphase Energy All rights reserved All trademarks or brands in this document are registered by their respective owner
Enphase   M215 Microinverter    DATA INPUT DATA  DC   M215-60-2LL-S22-IG   S23-IG   S24-IG  Recommended input power  STC  ...
Enphase Microinverters Enphase M250 The Enphase M250 Microinverter delivers increased energy harvest and reduces design and installation complexity with its all AC approach With the M250 the DC circuit is isolated and insulated from ground so no Ground Electrode Conductor GEC is required for the microinverter This further simplifies installation enhances safety and saves on labor and materials costs The Enphase M250 integrates seamlessly with the Engage Cable the Envoy Communications GatewayTM and Enlighten Enphase s monitoring and analysis software PRODUCTIVE Optimized for higher power modules Maximizes energy production Minimizes impact of shading dust and debris SIMPLE No GEC needed for microinverter No DC design or string calculation required Easy installation with Engage Cable RELIABLE 4th generation product More than 1 million hours of testing and 3 million units shipped Industry leading warranty up to 25 years
Enphase   Microinverters  Enphase M250     The Enphase   M250 Microinverter delivers increased energy harvest and reduces ...
Enphase M250 Microinverter DATA INPUT DATA DC M250 60 2LL S22 S23 S24 Recommended input power STC 210 300 W Maximum input DC voltage 48 V Peak power tracking voltage 27 V 39 V Operating range 16 V 48 V Min Max start voltage 22 V 48 V Max DC short circuit current 15 A Max input current 9 8 A OUTPUT DATA AC 208 VAC 240 VAC Peak output power 250 W 250 W Rated continuous output power 240 W 240 W Nominal output current 1 15 A A rms at nominal duration 1 0 A A rms at nominal duration Nominal voltage range 208 V 183 229 V 240 V 211 264 V Nominal frequency range 60 0 57 61 Hz 60 0 57 61 Hz Extended frequency range 57 62 5 Hz 57 62 5 Hz Power factor 0 95 0 95 Maximum units per 20 A branch circuit 24 three phase 16 single phase Maximum output fault current 850 mA rms for 6 cycles 850 mA rms for 6 cycles EFFICIENCY CEC weighted efficiency 240 VAC 96 5 CEC weighted efficiency 208 VAC 96 0 Peak inverter efficiency 96 5 Static MPPT efficiency weighted reference EN50530 99 4 Night time power consumption 65 mW max MECHANICAL DATA Ambient temperature range 40 C to 65 C Operating temperature range internal 40 C to 85 C Dimensions WxHxD 171 mm x 173 mm x 30 mm without mounting bracket Weight 2 0 kg Cooling Natural convection No fans Enclosure environmental rating Outdoor NEMA 6 FEATURES Compatibility Compatible with 60 cell PV modules Communication Power line Integrated ground The DC circuit meets the requirements for ungrounded PV arrays in NEC 690 35 Equipment ground is provided in the Engage Cable No additional GEC or ground is required Monitoring Free lifetime monitoring via Enlighten software Compliance UL1741 IEEE1547 FCC Part 15 Class B CAN CSA C22 2 NO 0 M91 0 4 04 and 107 1 01 Frequency ranges can be extended beyond nominal if required by the utility To learn more about Enphase Microinverter technology visit enphase com 2013 Enphase Energy All rights reserved All trademarks or brands in this document are registered by their respective owner
Enphase   M250 Microinverter    DATA INPUT DATA  DC   M250-60-2LL-S22 S23 S24  Recommended input power  STC   210 - 300 W ...
Engage Cable System and Accessories Enphase Engage Coupler The Engage Coupler is a watertight enclosure for connecting two power cables within an Enphase installation It supports single phase and three phase electrical service and is compatible with TC ER field cable The Engage Coupler provides an alternative to installing junction boxes within an array improving aesthetics and saving time and materials on the roof FAS T FLEXIBLE SMART Includes all parts needed for splicing and sealing Attaches easily to racking Compatible with Engage Cable or 12 AWG TC ER Supports single and three phase Easily concealed beneath solar array Reduces j box and conduit usage
Engage Cable System and Accessories  Enphase Engage Coupler     The Engage    Coupler is a watertight enclosure for connec...
Enphase Engage Coupler DATA COUPLER SPECIFICATIONS Degree of protection NEMA 6 IP67 Operating temperature 40 C to 65 C Rated current 20 A Rated voltage 600 V Accepts cable diameter 10 5 mm to 12 5 mm Conductor size 2 5 mm2 12 AWG Compatible cables Engage Cable 12 AWG TC ER NOT compatible with SOOW THHN 10 AWG TC ER cable membrane upper contact holder hex nut hex nut Approvals CSA approved for outdoor application with Enphase equipment Order no splice tube lower contact holder cable gland ET SPLK 05 sold in packs of 5 INSTALLATION BEST PRACTICES Carry the right tools Bring a small 4mm flathead screwdriver Use channel locks or wrenches to ensure proper torque gasket Ensure watertightness Pre mark cable sheath to ensure proper stripping length Screw the cable gland until it locks into position Check that the gasket is fully flush before tightening hex nut APPLICATIONS Engage to Engage Transition between portrait and landscape Engage Cable Make use of leftover segments of Engage Cable j box field cable Engage to TC ER Perform roof to roof transitions without junction boxes Create an extension for Engage Cable Engage Cable To learn more about Enphase Microinverter technology visit enphase com 2013 Enphase Energy All rights reserved All trademarks or brands in this document are registered by their respective owner chase Engage Coupler
Enphase   Engage Coupler    DATA  COUPLER SPECIFICATIONS  Degree of protection   NEMA 6, IP67  Operating temperature   -40...
PRODUCT DATA SHEET Controlled Document Engineering Drive 1530 Shields Drive Waukegan IL 60085 Toll Free 800 323 9355 Fax 847 689 1192 Royal 600V TFFN THHN THWN PVC TYPE TC ER Construction Parameters CONDUCTOR 12 AWG 10 AWG Class B stranded bare copper per ASTM B 3 and B 8 INSULATION COLOR CODE Premium Grade Polyvinyl Chloride PVC plus nylon Per ICEA Method 1 Table E 1 Black White Red Green Orange Blue White Black Red Black Green Black Orange Black Blue Black Black White Black sunlight and moisture resistant Polyvinyle Chloride PVC CCI ROYAL XX AWG X C PVCN PVC TYPE TC ER TFFN E79496 UL 600V 90C DRY OIL RES I SUNLIGHT RESISTANT DIRECT BURIAL SEQUENTIAL MARKING JACKET PRINT LEGEND CCI ROYAL XX AWG X C PVCN PVC TYPE TC ER THHN THWN E79496 UL 600V 90C DRY 75C WET OIL RES I SUNLIGHT RESISTANT DIRECT BURIAL SEQUENTIAL MARKING PHYSICAL PROPERTIES TEMPERATURE RANGE 25 C to 90 C 90 C Dry 75 C Wet Note TFFN is 90 C Dry only OIL RESISTANCE OIL RES I SUNLIGHT RESISTANT Yes DIRECT BURIAL Yes ELECTRICAL PROPERTIES VOLTAGE RATING 600V rms Max Industry Approvals o UL Standard 1277 Type TC ER o UL Standard 66 Type TFFN 16 AWG 18 AWG o UL Standard 83 Type THHN THWN 14 AWG thur 10 AWG o NEC Article 336 o EPA 40 CFR Part 261 Subpart C heavy metals per Table 1 TCLP method Part Number AWG No Cond Stranding 770207 12 2 7 0 0305 0 015 0 004 0 38 0 10 0 047 1 19 0 362 9 19 80 119 771204 12 4 7 0 0305 0 015 0 004 0 38 0 10 0 047 1 19 0 418 10 62 137 204 771002 10 2 7 0 0385 0 020 0 004 0 51 0 10 0 047 1 19 0 430 10 92 115 171 771004 10 4 7 0 0385 0 020 0 004 0 51 0 10 0 047 1 19 0 502 12 75 202 301 770112 10 12 7 0 0385 0 020 0 004 0 51 0 10 0 082 2 08 0 861 21 87 610 908 Insulation Wall Nom Inches mm Jacket Wall Nom Inches mm O D Nom Inches mm Net Weight Lb kft kg km Note All dimensions weights are nominal subject to industry standards and tolerances unless otherwise noted Not ER This product complies with European Directive 2002 95 EC RoHS The customer will accept all factory lengths and 10 percent of total order requested The information presented here is to the best of our knowledge true and accurate Since conditions of use are beyond Coleman Cable s control all product data presented is for informational purposes only and does not create a binding obligation or liability on Coleman Cable or confer any rights on any customer The sale of products s is conditioned upon acceptance of a purchase order subject to Coleman disclaims all liability in connection with the use of information contained herein or otherwise This specification is proprietary intellectual property of Coleman Cable Any information contained herein shall not be disclosed to any party without written consent of Coleman Cable Customer Company Name ________________________________________ Date _______________________________________ Customer Approval ______________________________________________ Customer Title _______________________________ Specification Issue Date November 9 2010 1 800 323 9355 Phone 1 847 689 1192 Fax ERF 15308 xls Designed By GJK 2010 CCI
PRODUCT DATA SHEET Controlled Document - Engineering Drive 1530 Shields Drive Waukegan, IL 60085 Toll-Free  800  323-9355 ...
SB 3000tl us 22 3800tl us 22 4000tl us 22 5000tl us 22 6000TL US 22 7000tl us 22 7700TL US 22 Sunny Boy 3000tl us 3800tl us 4000tl us 5000tl us 6000TL US 7000tl us 7700TL US OUTLET NOT INCLUDED Certified Innovative Powerful Flexible UL 1741 and 1699B compliant Integrated AFCI meets the requirements of NEC 2011 690 11 Secure Power Supply provides daytime power during grid outages 97 6 maximum efficiency Wide input voltage range Shade management with OptiTrac Global Peak MPP tracking Two MPP trackers provide numerous design options Extended operating temperature range SUNNY BOY 3000TL US 3800TL US 4000TL US 5000Tl us 6000TL US 7000Tl us 7700TL US Setting new heights in residential inverter performance The Sunny Boy 3000TL US 3800TL US 4000TL US 5000TL US 6000TL US 7000TL US 7700TL US represents the next step in performance for UL certified inverters Its transformerless design means high efficiency and reduced weight Maximum power production is derived from wide input voltage and operating temperature ranges Multiple MPP trackers and OptiTrac Global Peak mitigate the effect of shade and allow for installation at challenging sites The unique Secure Power Supply feature provides daytime power in the event of a grid outage High performance flexible design and innovative features make the Sunny Boy TL US series the first choice among solar professionals
SB 3000tl-us-22   3800tl-us-22   4000tl-us-22   5000tl-us-22   6000TL-US-22   7000tl-us-22   7700TL-US-22  Sunny Boy 3000t...
Technical data Input DC Max usable DC power cos 1 Max DC voltage Rated MPPT voltage range MPPT operating voltage range Min DC voltage start voltage Max operating input current per MPP tracker Number of MPP trackers strings per MPP tracker Output AC AC nominal power Max AC apparent power Nominal AC voltage adjustable AC voltage range AC grid frequency range Max output current Power factor cos Output phases line connections Harmonics Efficiency Max efficiency CEC efficiency Protection devices DC disconnection device DC reverse polarity protection Ground fault monitoring Grid monitoring AC short circuit protection All pole sensitive residual current monitoring unit Arc fault circuit interrupter AFCI compliant to UL 1699B Protection class overvoltage category General data Dimensions W H D in mm in DC Disconnect dimensions W H D in mm in Packing dimensions W H D in mm in DC Disconnect packing dimensions W H D in mm in Weight DC Disconnect weight Packing weight DC Disconnect packing weight Operating temperature range Noise emission typical Internal consumption at night Topology Cooling Electronics protection rating Features Secure Power Supply Display graphic Interfaces RS485 Speedwire Webconnect Warranty 10 15 20 years Certificates and permits more available on request NOTE US inverters ship with gray lids Type designation Sunny Boy 3000TL US 208 V AC 240 V AC Sunny Boy 3800TL US 208 V AC 240 V AC Sunny Boy 4000TL US 208 V AC 240 V AC 3200 W 600 V 175 480 V 125 500 V 125 V 150 V 18 A 15 A 4200 W 600 V 175 480 V 125 500 V 125 V 150 V 24 A 15 A 2 2 4200 W 600 V 175 480 V 125 500 V 125 V 150 V 24 A 15 A 3000 W 3000 VA 208 V 240 V 183 229 V 211 264 V 60 Hz 59 3 60 5 Hz 15 A 1 1 2 4 3330 W 3840 W 3330 VA 3840 VA 208 V 240 V 183 229 V 211 264 V 60 Hz 59 3 60 5 Hz 16 A 1 1 2 4 4000 W 4000 VA 208 V 240 V 183 229 V 211 264 V 60 Hz 59 3 60 5 Hz 20 A 1 1 2 4 97 2 96 5 97 6 96 5 97 2 96 5 97 5 97 0 97 2 96 5 97 5 97 0 I IV 25 dB A
Technical data Input  DC  Max. usable DC power    cos      1  Max. DC voltage Rated MPPT voltage range MPPT operating volt...
Accessories Speedwire Webconnect interface SWDM US 10 RS485 interface DM 485CB US 10 Fan kit for SB 3000 3800 4000 5000TL US 22 FANKIT02 10 Standard feature Optional feature Not available Data at nominal conditions Sunny Boy 5000TL US 208 V AC 240 V AC Sunny Boy 6000TL US 208 V AC Sunny Boy 7000TL US 240 V AC 5300 W 600 V 175 480 V 125 500 V 125 V 150 V 30 A 15 A 6300 W 600 V 210 480 V 125 500 V 125 V 150 V 30 A 15 A 4550 W 5000 W 4550 VA 5000 VA 208 V 240 V 183 229 V 211 264 V 60 Hz 59 3 60 5 Hz 22 A 1 1 2 4 208 V AC 5200 W 6000 W 5200 VA 6000 VA 208 V 240 V 183 229 V 211 264 V 60 Hz 59 3 60 5 Hz 25 A 1 1 2 4 97 2 96 5 97 6 97 0 97 0 96 5 240 V AC Sunny Boy 7700TL US 208 V AC 240 V AC 7300 W 600 V 245 480 V 125 500 V 125 V 150 V 30 A 18 A 8000 W 600 V 270 480 V 125 500 V 125 V 150 V 30 A 18 A 6000 W 7000 W 6000 VA 7000 VA 208 V 240 V 183 229 V 211 264 V 60 Hz 59 3 60 5 Hz 29 2 A 1 1 2 4 6650 W 7680 W 6650 VA 7680 VA 208 V 240 V 183 229 V 211 264 V 60 Hz 59 3 60 5 Hz 32 A 1 1 2 4 2 2 97 4 97 0 96 8 96 5 96 8 96 5 96 8 96 5 97 3 96 5 I IV 29 dB A
Accessories Speedwire Webconnect interface SWDM-US-10  RS485 interface DM-485CB-US-10  Fan kit for SB 3000 3800  4000 5000...
More efficient Shade management Easier Secure Power Supply Broad temperature range Flexible communications a new generation of innovation Transformerless design The Sunny Boy 3000TL US 3800TL US 4000TL US 5000TL US 6000TL US 7000TL US 7700TL US are transformerless inverters which means owners and installers benefit from high efficiency and lower weight A wide input voltage range also means the inverters will produce high amounts of power under a number of conditions Additionally transformerless inverters have been shown to be among the safest string inverters on the market An industry first the TLUS series has been tested to UL 1741 and UL 1699B and is in compliance with the arc fault requirements of NEC 2011 Increased energy production OptiTrac Global Peak SMA s shadetolerant MPP tracking algorithm quickly adjusts to changes in solar irradiation which mitigates the effects of shade and results in higher total power output And with two MPP trackers the TL US series can ably handle complex roofs with multiple orientations or string lengths An extended operating temperature range of 40 F to 140 F ensures power is produced Toll Free 1 888 4 SMA USA www SMA America com in all types of climates and for longer periods of time than with most traditional string inverters Leading monitoring and control solutions Secure Power Supply The new TL US residential line features more than high performance and a large graphic display The monitoring and control options provide users with an outstanding degree of flexibility Multiple communication options allow for a highly controllable inverter and one that can be monitored on Sunny Portal from anywhere on the planet via an Internet connection Whether communicating through RS485 or SMA s new plug and play WebConnect installers can find an optimal solution to their monitoring needs One of many unique features of the TL US residential series is its innovative Secure Power Supply With most grid tied inverters when the grid goes down so does the solarpowered home SMA s solution provides daytime energy to a dedicated power outlet during prolonged grid outages providing homeowners with access to power as long as the sun shines Simple installation As a transformerless inverter the TL US residential series is lighter in weight than its transformer based counterparts making it easier to lift and transport A new wall mounting plate features anti theft security and makes hanging the inverter quick and easy A simplified DC wiring concept allows the DC disconnect to be used as a wire raceway saving labor and materials The 3800TL US and 7700TL US models allow installers to maximize system size and energy production for customers with 100 A and 200 A service panels Wide Power Class Range Whether you re looking for a model to maximize a 100 A service panel or trying to meet the needs of a larger residential PV system the Sunny Boy TL US with Secure Power Supply has you covered Its wide range of power classes from 3 to 7 7 kW offers customers the right size for virtually any residential application The TL US series is not only the smartest inverter on the planet it s also the most flexible SMA America LLC SB5000TL US DUS143847 SMA and Sunny Boy are registered trademarks of SMA Solar Technology AG Printed on FSC certified paper All products and services described as well as technical data are subject to change even for reasons of country specific deviations at any time without notice SMA assumes no liability for errors or omissions For current information see www SMA Solar com The Sunny Boy TL US residential series has yet again redefined the category
More efficient  Shade management  Easier  Secure Power Supply  Broad temperature range  Flexible communications  a new gen...
SB 6000TLUS 12 SB 7000TLUS 12 SB 8000TLUS 12 SB 9000TLUS 12 SB 10000TLUS 12 SB 11000TLUS 12 Sunny Boy 6000TL US 7000TL US 8000TL US 9000TL US 10000TL US 11000TL US Innovative Economical Reliable Convenient irst transformerless SMA inverter F to be certified in accordance with UL 1741 irst inverter with arc fault circuit interF rupter listed according to UL 1699B Maximum efficiency of 98 7 Class leading CEC efficiency of 98 5 Superior MPP tracking with OptiTrac Transformerless with H5 topology ptiCool active temperature O management Integrated DC disconnect MA Power Balancer for threeS phase grid connection WebConnect compatible Sunny Boy 6000TL US 7000TL US 8000TL US 9000TL US 10000TL US 11000TL US Transformerless design maximum energy production The Sunny Boy TL US series is UL listed for North America and features SMA s innovative H5 topology resulting in superior efficiencies of more than 98 percent and unmatched solar power production The transformerless design reduces weight increases the speed of payback and provides optimum value for any residential or decentralized commercial PV system The Sunny Boy TL US series for North America is the ideal choice in transformerless technology
SB 6000TLUS-12   SB 7000TLUS-12   SB 8000TLUS-12   SB 9000TLUS-12   SB 10000TLUS-12   SB 11000TLUS-12  Sunny Boy 6000TL-US...
Technical data Input DC Max usable DC power cos 1 Max input voltage MPP voltage range rated input voltage Min input voltage initial input voltage Max input current Max input current per string Number of independent MPP inputs Strings per MPP input Combiner Box Output AC Rated power max apparent AC power Nominal AC voltage nominal AC voltage range AC power frequency range Max output current Power factor at rated power Feed in phases connection phases Efficiency CEC efficiency max efficiency Protective devices DC reverse polarity protection AC short circuit current capability Galvanic isolation All pole sensitive residual current monitoring unit Arc fault circuit interrupter according to UL 1699B Protection class Overvoltage category General data Dimensions W H D Dimensions of DC Disconnect W H D Weight Weight of DC Disconnect Operating temperature range Noise emission typical Self consumption night Topology Cooling concept Degree of protection Degree of protection of connection area Max permissible value for relative humidity non condensing Features DC connection AC connection Display Interface RS485 Bluetooth WebConnect Warranty 10 15 20 years Certificates and approvals more available on request Type designation Sunny Boy 6000TL US Sunny Boy 7000TL US 208 V 240 V 208 V 240 V 6300 W 600 V 300 V 480 V 345 V 300 V 360 V 20 9 A 20 9 A 1 6 6200 W 600 V 345 V 480 V 379 V 345 V 360 V 18 1 A 18 1 A 1 6 7300 W 600 V 300 V 480 V 345 V 300 V 360 V 24 4 A 24 4 A 1 6 7300 W 600 V 345 V 480 V 379 V 345 V 360 V 21 1 A 21 1 A 1 6 6000 W 6000 VA 6000 W 6000 VA 208 V 183 V 229 V 240 V 211 V 264 V 60 Hz 59 3 Hz 60 5 Hz 28 8 A 25 A 1 1 1 2 1 2 7000 W 7000 VA 7000 W 7000 VA 208 V 183 V 229 V 240 V 211 V 264 V 60 Hz 59 3 Hz 60 5 Hz 33 7 A 29 2 A 1 1 1 2 1 2 98 98 6 98 5 98 7 98 98 6 98 5 98 7 I IV I IV I IV I IV 470 615 240 mm 18 4 24 1 9 5 inch 187 297 190 mm 7 28 11 7 7 5 inch 35 kg 78 lb 35 kg 78 lb 3 5 kg 8 lb 3 5 kg 8 lb 40 C 60 C 40 F 140 F 46 dB A 46 dB A 0 15 W 0 15 W Transformerless H5 Transformerless H5 OptiCool OptiCool NEMA 3R NEMA 3R NEMA 3R NEMA 3R 100 100 470 615 240 mm 18 4 24 1 9 5 inch 187 297 190 mm 7 28 11 7 7 5 inch 35 kg 78 lb 35 kg 78 lb 3 5 kg 8 lb 3 5 kg 8 lb 40 C 60 C 40 F 140 F 46 dB A 46 dB A 0 15 W 0 15 W Transformerless H5 Transformerless H5 OptiCool OptiCool NEMA 3R NEMA 3R NEMA 3R NEMA 3R 100 100 Screw terminal Screw terminal Screw terminal Screw terminal Screw terminal Screw terminal Screw terminal Screw terminal Text line Text line Text line Text line UL1741 UL1998 IEEE1547 FCC Part 15 Class A B CAN CSA C22 2 107 1 1 UL 1699B SB 6000TLUS 12 SB 7000TLUS 12
Technical data Input  DC  Max. usable DC power    cos      1  Max. input voltage MPP voltage range     rated input voltage...
208 V Sunny Boy 8000TL US Sunny Boy 9000TL US 208 V 8300 W 600 V 345 V 480 V 379 V 345 V 360 V 24 1 A 24 1 A 1 6 8400 W 600 V 300 V 480 V 345 V 300 V 360 V 27 9 A 27 9 A 1 6 240 V 9400 W 600 V 300 V 480 V 345 V 300 V 360 V 31 0 A 31 0 A 1 6 8000 W 8000 VA 208 V 183 V 229 V 240 V 211 V 264 V 60 Hz 59 3 Hz 60 5 Hz 60 Hz 59 3 Hz 60 5 Hz 38 5 A 33 4 A 1 1 2 98 98 6 98 98 6 240 V 9400 W 600 V 345 V 480 V 379 V 345 V 360 V 27 1 A 27 1 A 1 6 9000 W 9000 VA 208 V 183 V 229 V 240 V 211 V 264 V 60 Hz 59 3 Hz 60 5 Hz 60 Hz 59 3 Hz 60 5 Hz 43 3 A 37 5 A 1 1 2 98 98 6 98 98 7 I IV I IV 470 615 240 mm 18 4 24 1 9 5 inch 187 297 190 mm 7 28 11 7 7 5 inch 35 kg 78 lb 3 5 kg 8 lb 40 C 60 C 40 F 140 F 46 dB A 0 15 W Transformerless H5 OptiCool NEMA 3R NEMA 3R 100 470 615 240 mm 18 4 24 1 9 5 inch 187 297 190 mm 7 28 11 7 7 5 inch 35 kg 78 lb 3 5 kg 8 lb 40 C 60 C 40 F 140 F 46 dB A 0 15 W Transformerless H5 OptiCool NEMA 3R NEMA 3R 100 Screw terminal Screw terminal Screw terminal Screw terminal Text line Text line UL1741 UL1998 IEEE1547 FCC Part 15 Class A B CAN CSA C22 2 107 1 1 UL 1699B SB 8000TLUS 12 SB 9000TLUS 12
208 V  Sunny Boy 8000TL-US  Sunny Boy 9000TL-US  208 V  8300  W 600  V 345  V       480  V     379  V 345  V     360  V 24...
Accessories Sunny Boy Combiner Box SBCBTL6 10 Bluetooth Piggy Back BTPBINV NR with External Antenna BTPB EXTANT NR Interface RS485 485USPB NR SMA Power Balancer Set PBL SBUS 10 NR Technical data Input DC Max usable DC power cos 1 Max input voltage MPP voltage range rated input voltage Min input voltage initial input voltage Max input current Max input current per string Number of independent MPP inputs Strings per MPP input Combiner Box Output AC Rated power max apparent AC power Nominal AC voltage nominal AC voltage range AC power frequency range Max output current Power factor at rated power Feed in phases connection phases Efficiency CEC efficiency max efficiency Protective devices DC reverse polarity protection AC short circuit current capability Galvanic isolation All pole sensitive residual current monitoring unit Arc fault circuit interrupter according to UL 1699B Protection class Overvoltage category General data Dimensions W H D Dimensions of DC Disconnect W H D Weight Weight of DC Disconnect Operating temperature range Noise emission typical Self consumption night Topology Cooling concept Degree of protection Degree of protection of connection area Max permissible value for relative humidity non condensing Features DC connection AC connection Display Interface RS485 Bluetooth WebConnect Warranty 10 15 20 years Certificates and approvals more available on request NOTE US inverters ship with gray lids Type designation Toll Free 1 888 4 SMA USA www SMA America com 208 V Sunny Boy 10000TL US 10500 W 600 V 300 V 480 V 345 V 300 V 360 V 35 A 35 A 1 6 Standard feature Optional feature Not available Data at nominal conditions Sunny Boy 11000TL US 240 V 240 V 10400 W 600 V 345 V 480 V 379 V 345 V 360 V 30 2 A 30 2 A 1 6 11500 W 600 V 345 V 480 V 379 V 345 V 360 V 33 3 A 33 3 A 1 6 10000 W 10000 VA 208 V 183 V 229 V 240 V 211 V 264 V 60 Hz 59 3 Hz 60 5 Hz 60 Hz 59 3 Hz 60 5 Hz 48 1 A 41 7 A 1 1 2 98 0 98 6 98 98 7 I IV 11000 W 11000 VA 240 V 211 V 264 V 60 Hz 59 3 Hz 60 5 Hz 45 8 A 1 1 2 98 98 7 I IV 470 615 240 mm 18 4 24 1 9 5 inch 187 297 190 mm 7 28 11 7 7 5 inch 35 kg 78 lb 3 5 kg 8 lb 40 C 60 C 40 F 140 F 46 dB A 46 dB A 0 15 W 0 15 W Transformerless H5 Transformerless H5 OptiCool OptiCool NEMA 3R NEMA 3R NEMA 3R NEMA 3R 100 100 Screw terminal Screw terminal Screw terminal Screw terminal Text line Text line UL1741 UL1998 IEEE1547 FCC Part 15 Class A B CAN CSA C22 2 107 1 1 UL 1699B SB 10000TLUS 12 SB 11000TLUS 12 SMA America LLC SUNNYBOY611TL DUS143017 Sunny Boy OptiCool H5 and SMA are registered trademarks of SMA Solar Technology AG Printed on FSC certified paper All products and services described as well as technical data are subject to change even for reasons of country specific deviations at any time without notice SMA assumes no liability for errors or omissions For current information see www SMA Solar com WebConnect Piggy Back SWPB US 10
Accessories Sunny Boy Combiner Box SBCBTL6-10  Bluetooth Piggy-Back BTPBINV-NR with External Antenna BTPB-EXTANT-NR  Inter...
Solar inverters ABB string inverters PVI 3 0 3 6 3 8 4 2 TL OUTD 3 0kW to 4 2kW This family of single phase string inverters complements the typical number of rooftop solar panels enabling homeowners to get the most efficient energy harvesting for the size of the property This inverter offers a dual input section that processes two strings with independent Multiple Power Point Tracking MPPT This is especially useful for rooftop installations with two different orientations from two sub arrays oriented in different directions or unbalanced strings for example East and West The dual input sections with independent MPPT enable a more optimal energy harvesting condition The high speed MPPT offers realtime power tracking and improved energy harvesting The flat efficiency curve ensures highefficiency at all output levels allowing a consistent and stable performance across the entire input voltage and output power range The transformerless operation gives the highest efficiency of up to 97 0 percent The wide input voltage range makes the inverter suitable to low power installations with reduced string size This rugged outdoor inverter has been designed to be a completely sealed unit to withstand the harshest environmental conditions Highlights Single phase and three phase output grid connection Wide input voltage range for increased stringing flexibility and energy harvesting The high speed and precise MPPT algorithm offers real time power tracking and improved energy harvesting Outdoor NEMA 4X rated enclosure for unrestricted use under any environmental conditions Integrated DC disconnect switch in compliance with international Standards S Version
Solar inverters  ABB string inverters PVI-3.0 3.6 3.8 4.2-TL-OUTD 3.0kW to 4.2kW  This family of single-phase string inver...
Additional highlights RS 485 communication interface for connection to laptop or data logger Integrated Arc Fault Detection and Interruption A Version Available with optional Wifi Logger Card for wireless monitoring Technical data and types Type code Mechanical specifications PVI 3 0 OUTD US PVI 3 6 OUTD US 3000W 3600W Nominal output power Maximum output power wattage Rated grid AC voltage Input side DC Number of independent MPPT channels Maximum usable power for each channel Absolute maximum voltage Vmax Start up voltage Vstart Full power MPPT voltage range Operating MPPT voltage range Maximum current Idcmax for both MPPT in parallel Maximum usable current per channel Maximum short circuit current limit per channel Number of wire landing terminals per channel Array wiring termination Output side AC Grid connection type Adjustable voltage range Vmin Vmax V Grid frequency Adjustable grid frequency range Maximum current Iac max Power factor Total harmonic distortion at rated power Grid wiring termination type Input protection devices Reverse polarity protection Over voltage protection type PV array ground fault detection Output protection devices Anti islanding protection Over voltage protection type Maximum AC OCPD rating Efficiency Maximum efficiency CEC efficiency Operating performance Nighttime consumption Stand by consumption Communication User interface Remote monitoring 1xRS485 incl Environmental Ambient air operating temperature range Ambient air storage temperature range Relative humidity Acoustic noise emission level Maximum operating altitude without derating 3000 W 208V 33001 W 240V 3300 1 W 277V 3600 W 208V 2 2000W 4000 1 W 240V PVI 3 8 OUTD US 4000 1 W 277V 3300 W 3300 W 208V 2 3000W PVI 4 2 OUTD US 3800W 4200 1 W 240V 4200 1 W 277V 4200W 4200 W 208V 2 3000W 4600 1 W 277V 2 3000W 600V 200V adj 120 350V 120 530V 140 530V 0 7 x Vstart 580V 90V 160 530V 4600 1 W 240V 140 530V 20A 32A 32A 10A 16A 16A 32A 16A 12 5A 20 0A 20 0A 20 0A 2 pairs Terminal block pressure clamp AWG20 AWG6 1 2W 183228V Split 3W 211264V 1 2W 244304V 14 5 ARMS 14 5 ARMS 12 0 ARMS 1 2W 183228V Split 3W 211264V 1 1 Split1 2W 2W 3W 2W 244183211244304V 228V 264V 304V 60Hz 57 60 5Hz 17 2 16 0 16 0 16 0 16 0 16 0 ARMS ARMS ARMS ARMS ARMS ARMS 0 995 2 Terminal block Pressure clamp AWG20 AWG6 1 2W 183228V Split 3W 211264V 1 2W 244304V 20 0 ARMS 20 0 ARMS 20 0 ARMS Yes Varistor 2 for each channel Pre start up RISO and dynamic GFDI requires floating arrays 20ARMS 20ARMS 15ARMS 96 9 97 97 96 0 6WRMS 8WRMS 16 characters x 2 lines LCD display VSN700 Data Logger opt VSN300 Wifi Logger Card opt 13 F to 140 F 25 C to 60 C with derating above 122 F 50 C 40 F to 176 F 40 C to 80 C 0 100 RH condensing 50 db A 1m 6560ft 2000m 1 Capability enabled at nominal AC voltage and with sufficient DC power available 2 ABB solar inverters Product flyer for PVI 3 0 3 6 3 8 4 2 TL OUTD Meets UL1741 IEEE1547 requirements Varistor 2 L1 L2 L1 G 25ARMS 20ARMS 20ARMS 20ARMS 20ARMS 20ARMS 25ARMS 25A RMS 25A RMS 97
Additional highlights          RS-485 communication interface  for connection to laptop or data logger         Integrated ...
Block diagram of PVI 3 0 3 6 3 8 4 2 TL OUTD IN1 1 MPPT 1 DC DC IN1 IN1 IN1 IN1 IN1 INVERTER DC AC BULK CAPS GRID PARALLEL RELAY LINE FILTER IN1 2 L1 IN1 1 IN1 2 IN1 N L2 DC AFDI MPPT 2 DC DC IN2 1 IN2 IN2 IN2 IN2 IN2 IN2 2 RESIDUAL CURRENT DETECTION IN2 PE IN2 1 RS485 T R IN2 2 T R STANDARD VERSION A VERSION RTN S VERSION REMOTE CONTROL DC AC DSP CONTR DC DC DSP CONTR R P GROUND FAULT DETECTION R ALARM N C N O C CONTROL CIRCUIT Remote control function not available on A version PVI 4 2 OUTD US PVI 4 2 OUTD US 100 00 96 4 85 00 96 80 00 95 6 75 00 95 94 70 00 97 0 200 Vdc 65 00 96 2 60 00 340 Vdc 96 4 50 00 480 Vdc 93 55 00 45 00 96 40 00 96 92 35 00 30 00 25 00 10 20 30 40 50 60 70 80 90 100 of Rated Output Power 94 92 215 95 2 95 2 94 92 250 345 15 00 10 00 92 300 20 00 400 5 00 480 95 2 of Rated Power Ef ciency 96 6 90 00 96 91 0 97 0 95 00 96 97 94 8 94 4 94 93 6 93 2 92 8 92 4 92 91 6 MPPT Voltage V Technical data and types Type code Mechanical specifications Enclosure rating Cooling Dimensions H x W x D Weight Shipping weight Mounting system Conduit connections2 DC switch rating per contact A V Safety Isolation level Safety and EMC standard Safety approval Warranty Standard warranty Extended warranty Available models Standard without DC swtich and wiring box Standard with DC switch and wiring box With DC switch wiring box arc fault detector and interrupter 2 When equipped with optional DC switch and wiring box All data is subject to change without notice PVI 3 0 OUTD US PVI 3 6 OUTD US PVI 3 8 OUTD US PVI 4 2 OUTD US NEMA 4X Natural convection 33 8 x 12 8 x 8 7in 859 x 325 x 222mm 2
Block diagram of PVI-3.0 3.6 3.8 4.2-TL-OUTD IN1.1     MPPT 1  DC DC                     IN1  IN1  IN1  IN1  IN1  -  -  - ...
Solar inverters ABB string inverters PVI 5000 6000 TL OUTD 5kW to 6kW Designed for residential and small commercial PV installations this inverter fills a specific niche in the ABB product line to cater for those installations producing between 5kW and 20kW This inverter includes dual input section to process two strings with independent Multiple Power Point Tracker MPPT The high speed and precise MPPT algorithm offers real time power tracking and energy harvesting Flat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power range This outdoor inverter has been designed as a completely sealed unit to withstand the harshest environmental conditions The wide input voltage range makes the inverter suitable for low power installations with reduced string size The transformerless operation offers high performance efficiencies of up to 97 1 percent Free remote monitoring capability is available with every installation This enables homeowners to view their energy production and offers installers a proactive and economic way of maintaining and troubleshooting the system Highlights Single phase and three phase output grid connection Wide input range for increased stringing flexibility The high speed and precise MPPT algorithm offers real time power tracking and improved energy harvesting Outdoor NEMA 4X rated enclosure for unrestricted use under any environmental condition Integrated DC disconnect switch in compliance with international Standards S Version
Solar inverters  ABB string inverters PVI-5000 6000-TL-OUTD 5kW to 6kW  Designed for residential and small commercial PV i...
Additional highlights The RS 485 connection enables communication interface from inverter to a laptop or data logger Integrated Arc Fault Detection and Interruption A Version Available with optional Wifi Logger Card for wireless monitoring Technical data and types Type code Input side Nominal output power Maximum output power Rated grid AC voltage Input side DC Number of independent MPPT channels Maximum usable power for each channel Absolute maximum voltage Vmax Start up voltage Vstart Full power MPPT voltage range Operating MPPT voltage range Maximum current Idcmax for both MPPT in parallel Maximum usable current per channel Maximum short circuit current per channel Number of wire landing terminals per channel Array wiring termination Output side AC Grid connection type Adjustable voltage range Vmin Vmax Grid frequency Adjustable grid frequency range Maximum current Iac max ARMS Power factor Total harmonic distortion at rated power Contributory fault current1 Grid wiring termination type Input Reverse polarity protection Over voltage protection type PV array ground fault detection Output Anti islanding protection Over voltage protection type Maximum AC OCPD rating Efficiency Maximum efficiency CEC efficiency User interface Operating performance Stand by consumption Nighttime consumption Communication User interface Remote monitoring 1xRS485 incl Environmental PVI 5000 OUTD US 208V PVI 6000 OUTD US 5000W 5000W 240V 6000W 6000W 240V 277V 277V 2 4000W 600V 200V adj 120 350 145 530V 175 530V 0 7 x Vstart 580V 90V 36A 18A 22A 2 Pairs Terminal block pressure clamp AWG20 AWG6 1 2W 183 228V 27ARMS 36 25 Apk 25 63ARMS Split 3W 221 264V 1 2W 244 304V 1 2W 183 228V Split 3W 211 264V 60Hz 57 60 5Hz 23ARMS 20ARMS 30ARMS 28ARMS 0 995 2 36 5 Apk 31 75 Apk 36 25 Apk 36 5 Apk 25 81A RMS 22 45A RMS 25 63A RMS 25 81A RMS Terminal block pressure clamp AWG20 AWG4 1 2W 244 304V 24A RMS 31 75 Apk 22 45A RMS Yes Varistor 2 for each channel Pre start up RISO and dynamic GFDI requires floating arrays 35A 30A 96 Meets UL1741 IEEE1547 requirements Varistor 2 L1 L2 L1 G 25A 40A 96 5 97 1 96 5 96 Graphic display
Additional highlights          The RS-485 connection enables communication interface from inverter to a laptop or data log...
Block diagram of PVI 5000 6000 TL OUTD MPPT 1 DC DC IN1 IN1 INVERTER DC AC BULK CAPS LINE FILTER IN1 1 IN1 IN1 1 GRID PARALLEL RELAY L1 IN1 N DC AFDI L2 IN2 1 IN2 IN2 Efficiency IN2 A VERSION MPPT 2 DC DC IN2 IN2 1 96 2 STANDARD VERSION 480 95 400 96 5 96 8 345 97 95 9 10 MPPT Voltage GROUND 300 FAULT DETECTION 96 5 96 2 20 30 50 75 Remote control function not available on A version of Rated Output Power RESIDUAL CURRENT DETECTION 97 96 8 96 5 96 2 95 9 95 6 95 3 95 94 7 94 4 94 1 93 8 93 5 93 2 92 9 92 6 250 100 PE RS485 T R T R DC AC DSP CONTR DC DC DSP CONTR RTN REMOTE CONTROL R R P ALARM N C N O CONTROL CIRCUIT C PVI 5000 6000 OUTD US PVI 5000 6000 OUTD US Efficiency 100 480 96 2 99 95 Ef ciency 98 400 96 5 97 96 8 96 345 97 95 94 93 250 Vdc 345 Vdc 480 Vdc 92 91 96 2 90 0 10 20 30 40 50 60 70 of Rated Output Power 80 90 300 96 5 95 9 100 10 MPPT Voltage 20 30 50 75 of Rated Output Power 250 100 97 96 8 96 5 96 2 95 9 95 6 95 3 95 94 7 94 4 94 1 93 8 93 5 93 2 92 9 92 6 Technical data and types Conduit connections DC switch rating per contact Safety Isolation level Safety and EMC standard Safety approval Warranty Standard warranty Extended warranty Available models Standard with DC switch floating array With DC switch wiring box and arc fault detector and interruptor With DC switch wiring box arc fault detector and interruptor and revenue grade meter PVI 5000 OUTD US PVI 6000 OUTD US 100 NEMA 4X Natural convection 41 4x12 8x8 6 in 1052 x 325 x218 mm 97
Block diagram of PVI-5000 6000-TL-OUTD    MPPT 1  DC DC        IN1  IN1  -  INVERTER  DC AC   BULK CAPS  LINE FILTER  IN1....
Solar inverters ABB string inverters PVI 10 0 I OUTD 10kW PV DC AC Designed for commercial systems the PVI 10 0 isolated three phase inverter is highly unique in its ability to control the performance of the PV panels especially during periods of variable weather conditions The dual Multiple Power Point Tracker MPPT maximizes energy production and increases design flexibility This dual independent MPPT functionality enables optimal energy harvesting from two sub arrays oriented at different azimuths tilts and varying string lengths The wide input voltage range makes this inverter suitable for installations with a reduced string size The flat efficiency curves offer high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power range Disconnect This inverter is feature rich enabling the desired design flexibility to master any design challenge The input voltage range makes this inverter suitable for installations with reduced string size The PVI 10 0 I is built to endure harsh environmental conditions with its NEMA 4X rating The PVI 10 0 I is available with an optional fully integrated DC combiner box equipped either with DC or AC and DC disconnect switches and DC fuses Highlights This Isolated inverter is available in 208V 480V and 600V outputs It has an efficiency rating of up to 97 3 The high speed and precise MPPT algorithm enables real time power tracking and improved energy harvesting The electrolyte free power converter increases the life expectancy and reliability
Solar inverters  ABB string inverters PVI-10.0-I-OUTD 10kW  PV DC   AC  Designed for commercial systems, the PVI-10.0, iso...
Additional highlights True three phase bridge topology for DC AC output conversion It features a night wake up button to access energy harvesting data and information when inverter is sleeping The dual independent MPPT allows optimal energy harvesting from two sub arrays oriented in different azimuths and tilts NEMA 4X outdoor enclosure for use under any environmental conditions Integrated combiner box equipped with a DC switch in compliance with international standards S1 S2 RS 485 communication interface for connection to laptop or datalogger PV DC AC Disconne ct Technical data and types Type code Nominal output power Maximum output power Rated grid AC voltage Input side DC Number of independent MPPT Channels Maximum usable power for each MPPT channel Absolute maximum voltage Vmax Start up voltage Vstart Full power MPPT voltage range Operating MPPT voltage range Maximum current Idcmax for both MPPT in parallel Maximum usable current per MPPT channel Maximum short circuit current Isc max per MPPT channel Maximum short circuit current Isc max for both MPPT in parrallel Number of inputs strings per MPPT channel Array wiring termination type Output side AC Grid connection type Default voltage range Nominal grid frequency Adjustable grid frequency range Maximum Current Iac max phase Power factor Total harmonic distortion at rated power Grid wiring termination type Fault current Input protection devices Reverse polarity protection Over voltage protection type PV array ground fault detection Output protection devices Anti islanding protection Over voltage protection type Efficiency Maximum efficiency CEC efficiency Operating parameters Feed in power threshold Stand by consumption Communication User interface display Standard communication interfaces Optional remote monitoring logger Environmental Ambient air operating temperature range Ambient storage temperature range Relative humidity Acoustic noise emission level Maximum operating altitude without derating PVI 10 0 I OUTD US 10000W 11000W 208V 10000W 11000W 480V 10000W 10000W 208V 10000W 10000W 480V 10000W 10000W 600V 2 programmable for 1 MPPT 6800W 520V 200V adj 120V min 220 470V 0 7 x Vstart 520 48A 24A 29A 58A Standard version 2 S1 version 3 S2 version 3 Terminal block pressure clamp 20AWG 6AWG 183 228V 30 0A rms 44 4A rms 3 3W or 4W Ground 183 228V 422 528V 60Hz 57 63 Hz 14 0Arms 30 0Arms 14 0Arms 0 995 adj 0 9
Additional highlights          True three-phase bridge topology for DC AC output conversion.         It features a night w...
Block diagram of PVI 10 0 I OUTD IN1 1 IN1 2 IN1 3 IN1 IN1 1 IN1 2 IN1 IN1 1 GRID PARALLEL RELAY LINE FILTER L1 HF Transformer IN1 L1 L1 L2 L2 L2 L3 L3 MPPT1 DC DC IN1 2 INVERTER DC AC BULK CAPS IN1 1 L3 N N N PE IN1 2 PE IN1 3 MPPT 2 DC DC IN2 1 IN2 1 IN2 2 IN2 IN2 1 IN2 2 IN2 2 IN2 IN2 3 IN2 1 HF TRANSFORMER S2 VERSION IN2 IN2 2 IN2 3 RS485 T R STANDARD VERSION T R S1 S2 VERSION GROUND FAULT DETECTION RTN DC AC DSP CONTR DC DC DSP CONTR REMOTE CONTROL R R P ALARM N C N O C CONTROL CIRCUIT PVI 10 I OUTD 98 Ef ciency 97 96 95 220 Vdc 220 Vdc 94 362 Vdc 362 Vdc 93 416 Vdc 416 Vdc 92 0 10 20 30 40 50 60 70 80 90 100 of Rated Output Power Technical data and types Type code Mechanical specifications Enclosure rating Cooling Dimensions H x W x D Unit weight Shipping weight Conduit connections Mounting system Ground fault detector fuse size type Optional string combiner fuse size type S1 and S2 Optional DC switch current rating per contact Safety Isolation level Safety and EMC standard Safety Approval Warranty Standard warranty Extended Warranty Available models PVI 10 0 I OUTD US PVI 10 0 I OUTD CAN NEMA 4X Natural convection Standard 28 2 x 25 4 x 8 7in 716 x 645 x 222mm S1 S2 version 37 7 x 25 4 x 8 7in 958 x 645 x 222mm Standard 101lbs 45 8kg S1 107 lbs 48 5kg S2 114lbs 51 7kg With pallet 254lbs
Block diagram of PVI-10.0-I-OUTD  IN1.1    IN1.2        IN1.3     IN1 IN1.1 -  IN1.2 -   IN1 IN1.1 -   -  GRID PARALLEL RE...
Solar inverters ABB string inverters PVI 12 0 I OUTD 12kW PV DC AC Designed for commercial systems the PVI 12 0 isolated three phase inverter is highly unique in its ability to control the performance of the PV panels especially during periods of variable weather conditions The dual Multiple Power Point Tracker MPPT maximizes energy production and increases design flexibility This dual independent MPPT functionality enables optimal energy harvesting from two sub arrays oriented at different azimuths tilts and varying string lengths The wide input voltage range makes this inverter suitable for installations with a reduced string size The flat efficiency curves offer high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power range Disconnect This inverter is feature rich enabling the desired design flexibility to master any design challenge The natural convection cooling and electrolytic free design leads to a longer product lifetime and reliability This inverter comes with a night wake up button to access energy harvesting data and information when inverter is in sleep mode The PVI 12 0 I is available with an optional fully integrated fused DC combiner box equipped either with DC or AC and DC disconnect switches Highlights True three phase bridge topology for DC AC output conversion Available in 480V and 600V outputs levels This inverter operates with a 97 3 efficiency rating High speed and precise MPPT algorithm which enables real time power tracking and improved energy harvesting The electrolyte free power converter increases the life expectancy and reliability of the inverter
Solar inverters  ABB string inverters PVI-12.0-I-OUTD 12kW  PV DC   AC  Designed for commercial systems, the PVI-12.0-isol...
Additional highlights Integrated combiner box equipped with a DC switch in compliance with international standards S1 S2 RS 485 communication interface for connection to laptop or data logger It features a night wake up button to access energy harvesting data and information when inverter is sleeping The dual independent MPPT allows optimal energy harvesting from two sub arrays oriented in different azimuths and tilts NEMA 4X outdoor enclosure for use under any environmental conditions PV DC AC Disconn ect Technical data and types Type code Nominal output power Maximum output power Rated grid AC voltage Input side DC Number of independent MPPT channels Maximum usable power for each MPPT channel Absolute maximum voltage Vmax Start up voltage Vstart Full power MPPT voltage range Operating MPPT voltage range Maximum current Idcmax for both MPPT in parallel Maximum usable current per MPPT channel Maximum short circuit current Isc max per MPPT channel Maximum short circuit current Isc max for both MPPT in parrallel Number of inputs strings per MPPT channel Array wiring termination type Output side DC Grid connection type Default voltage range Nominal grid frequency Adjustable grid frequency range Maximum current lac max phase Power factor Total harmonic distortion at rated power Grid wiring termination type Fault current Input protection devices Reverse polarity protection Over voltage protection type PV array ground fault detection Output protection devices Anti islanding protection Over voltage protection type Efficiency Maximum efficiency CEC efficiency Operating parameters Feed in power threshold Stand by consumption Communication User interface display Standard communication interfaces Optional remote monitoring logger Environmental Ambient air operating temperature range Ambient storage temperature range Relative humidity Acoustic noise emission level Maximum operating altitutde without derating Capability enabled at nominal AC voltage and with sufficient DC power available Information in this document is subject to change without notice 2 ABB Solar Inverters Product flyer for PVI 12 0 I OUTD XX US CAN PVI 12 0 I OUTD US PVI 12 0 I OUTD CAN 12000W 13200W 480V 480V 12000W 12000W 600V 2 programmable for 1 MPPT 6800W 520V 200V adj 120V min 250 470V 0 7 x Vstart 520 50A 25A 29A 58A Standard version 2 S1 version 3 S2 version 3 Terminal block pressure clamp 20AWG 6AWG 3 3W or 4W Ground 422V 528V 60Hz 57 63 Hz 16 0A rms 16 0Arms 0 995 adj 0 9
Additional highlights          Integrated combiner box equipped with a DC switch in compliance with international standard...
Block diagram of PVI 12 0 I OUTD IN1 2 IN1 3 IN1 IN1 1 IN1 2 IN1 IN1 1 GRID PARALLEL RELAY LINE FILTER L1 HF Transformer IN1 L1 L1 L2 L2 L2 L3 L3 MPPT 1 DC DC IN1 2 INVERTER DC AC BULK CAPS IN1 1 IN1 1 L3 N N N PE IN1 2 PE IN1 3 MPPT 2 DC DC IN2 1 IN2 2 IN2 IN2 1 IN2 2 IN2 1 IN2 2 IN2 IN2 3 IN2 1 HF TRANSFORMER S2 VERSION IN2 IN2 2 IN2 3 RS485 T R STANDARD VERSION T R S1 S2 VERSION DC AC DSP CONTR DC DC DSP CONTR GROUND FAULT DETECTION RTN REMOTE CONTROL R R P ALARM N C N O C CONTROL CIRCUIT PVI 12 0 I OUTD Ef ciency 97 96 95 250 Vdc 94 370 Vdc 93 416 Vdc 92 0 10 20 30 40 50 60 70 80 90 100 of Rated Output Power Technical data and types Type code Mechanical specifications Enclosure rating Cooling Dimensions H x W x D Unit weight Shipping weight Conduit connections Mounting system Ground fault detector fuse size type Optional string combiner fuse size type Optional DC switch current rating per contact Safety Isolation level Safety and EMC standard Safety Approval Warranty Standard warranty Extended warranty Available models PVI 12 0 I OUTD US PVI 12 0 I OUTD CAN NEMA 4X Natural convection Standard 28 2 x 25 4 x 8 7in 716 x 645 x 222mm S1 S2 version 37 7 x 25 4 x 8 7in 958 x 645 x 222mm Standard 101lbs 45 8kg S1 107lbs 48 5kg S2 114lbs 51 7kg With pallet 254lbs
Block diagram of PVI-12.0-I-OUTD  IN1.2     IN1.3     IN1 IN1.1 -  IN1.2 -         IN1 IN1.1 -   GRID PARALLEL RELAY  LINE...
Solar inverters ABB string inverters TRIO 20 0 27 6 TL OUTD 20kW to 27 6kW A commercial photovoltaic PV system using a TRIO based modular architecture can reduce BOS costs by as much as 40 percent The TRIO is a modular option using models at 20 0kW and 27 6kW It can be used alone for a 20kW system or combined as building blocks for large commercial and utility scale systems With two independent Multiple Power Point Trackers MPPT and peak efficiency ratings of 98 2 percent these inverters offer superior energy harvest The flat efficiency curves offer high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power range Employing fan less convection cooling and no electrolytic capacitors TRIO is designed for long service life The TRIO offers flexible power factor control to comply with utility grid requirements where required As the first 1000Vdc string inverter certified to UL1741 the TRIO leads the way for efficient cost saving decentralized system design The TRIO is equipped with integrated Modbus and utility interactive controls including adjustable power factor and curtailment Additional AC and DC protections as well as arc fault circuit interruption are all available in the TRIO These inverters provide the monitoring control features and protection required in today s commercial solar installations Highlights This flexible and dependable threephase string inverter has innovative features to lower system Levelized Cost Of Energy LCOE and improve Return on Investment ROI on commercial solar installations Fully utilize available roof space and maximize harvest with dual independent MPPT Wall mountable design and 1000Vdc input voltage lower installation and material costs
Solar inverters  ABB string inverters TRIO-20.0 27.6-TL-OUTD 20kW to 27.6kW  A commercial photovoltaic  PV  system using a...
Additional highlights Multiple AC and DC level protection options available including arc fault circuit interruption AFCI Wide DC input voltage and operating temperature range enable greater PV array design flexibility Modular design capability improves system availability and eliminates single point of failure Utility interactive control features and Modbus protocol integrates with monitoring and control systems Design uses natural convection cooling and no electrolytic capacitors for increased reliability This inverter comes with a standard 10 year warranty Extended warranty offered at 15 and 20 years Technical data and types Type code Nominal output power Maximum output power Rated grid AC voltage Input side DC Number of independent MPPT channels Maximum usable power for each MPPT channel Absolute maximum voltage V max Start up voltage Vstart Full power MPPT voltage range Operating MPPT voltage range Maximum usable current Idc max per MPPT channel Maximum short circuit current Isc max per MPPT channel Number of inputs strings per MPPT channel Array wiring termination type Output side AC Grid connection type Default voltage range Adjustable voltage range Nominal grid frequency Adjustable grid frequency range Maximum current lac max phase Power factor Total harmonic distortion at rated power Grid wiring termination type Input protection devices Reverse polarity protection Supplementary over voltage protection type for each MPPT PV array ground fault detection Output protection devices Anti islanding protection Supplementary over voltage protection type Optional AC fused disconnect current rating per contact Operating performance Maximum efficiency CEC efficiency Feed in power threshold Communication User interface display Standard communication interfaces Optional remote monitoring logger Environmental Ambient operating temperature range Ambient storage temperature range Relative humidity Acoustic noise emission level Maximum operating altitude without derating Mechanical specifications Enclosure rating Cooling Dimensions H x W x D Unit weight Conduit connections Mounting system TRIO 20 0 TL OUTD TRIO 27 6 TL OUTD 20000W 22000W 1 27600W 30000W 1 480V 2 Programmable for 1 MPPT 12000W 16000W 1000V 360V adj 250 500V 450 800V 520 800V 200 950V 25 0A 30 9A 30 0A 36 0A S version 1 S1 S1A S1B versions 4 Terminal block screw terminal copper only S 12AWG 2AWG S1 S1A S1B 12AWG 6AWG 3 3W or 4W Ground 422 528V 240 552V 60Hz 57 63Hz 27 0 A rms 0 995 adj 0 8 or 0 9 for active power 20kW Pass through terminal Tension clamp Copper 8AWG 4AWG 0 995 adj 0 8 or 0 9 for active power 27 6kW Pass through terminal Tension clamp Copper 6AWG 4AWG Yes passive inverter protection only 2 S1 S1A S1B version plug in class II modular surge arrestor Meets UL1741 NEC requirements Meets UL1741 IEEE 1547 requirements S1A version plug in class II modular surge arrestor 35A 45A 98 2 97 5 65WRMS 70WRMS 5 5 x 1 25 graphic display 1 RS485 connection can be configured for Aurora protocol or Modbus RTU Support for optional monitoring expansion cards Aurora Logger Commercial optional 22 F to 140 F 30 C to 60 C Derating above 113 F 45 C 40 F to 185 F 40 C to 85 C 0 100 condensing
Additional highlights          Multiple AC and DC level protection options available including arc-fault circuit interrupt...
Block diagram of TRIO 20 0 27 6 TL OUTD IN1A IN1A IN1C IN1D IN1D IN1B IN1 IN1A IN1B IN1C GRID PARALLEL RELAY IN1C L2 L3 L3 L3 N N N PE PE L2 IN1D IN1D LINE FILTER IN1 IN1 IN1A L1 L2 L2 N INVERTER DC AC BULK CAPS L1 L1 L2 L1 MPPT 1 DC DC IN1C L1 L3 IN1B IN1B L3 DC AFCI S S1 VERSION N IN2A IN2A IN2B IN2B IN2C PE MPPT 2 DC DC IN2C S1A VERSION IN2D IN2D L1 IN2A IN2B IN2B IN2C IN2C IN2D IN2D L2 L3 IN2 IN2A L1 L2 IN2 IN2 L3 N N PE DC DC DSP CONTR P S1 S1A S1B VERSION S1 S1A S1B AFCI VERSION A S1B VERSION DC AC DSP CONTR SERVICE T R new version implemented T R CONTROL CIRCUIT GND MODBUS IN1 IN1 IN1 IN1 SERVICE REMOTE ON OFF R AN 1 IN2 GND AN 2 ALARM IN MODE IN2 GND P MODBUS IN2 IN2 IN2 T R SERVICE OR NORMAL IN2 T R GRID STANDARD SETTING IN1 IN1 DC AFCI ON OFF EXT N C N O WIRING BOX CIRCUIT C S AFCI Version A S VERSION an expansion slot for future implementation of new communication systems is available TRIO 20 0 TL US TRIO 27 6 TL US 100 95 Ef ciency Ef ciency 100 450 Vdc 90 700 Vdc 85 800 Vdc 95 520 Vdc 715 Vdc 85 80 90 800 Vdc 80 0 10 20 30 40 50 60 70 80 90 100 0 10 20 of Rated Output Power 30 40 50 60 70 80 90 100 of Rated Output Power Technical data and types Type code Safety Isolation level Safety and EMC standard Safety approval Warranty Standard warranty Extended warranty Available models Standard with DC disconnect With DC disconnect DC fuses and DC surge protection With DC disconnect DC fuses DC surge protection and AC surge protection With DC disconnect DC fuses DC surge protection and AC fused disconnect Standard with DC disconnect and Arc Fault circuit interruption With DC disconnect DC fuses DC surge protection and Arc Fault circuit interruption With DC Disconnect DC fuses DC surge protection AC surge protection and Arc Fault circuit interruption With DC disconnect DC fuses DC surge protection AC fused disconnect and Arc fault circuit interruption TRIO 2 0 TL OUTD TRIO 27 6 TL OUTD Transformerless Floating Array Required UL1741 IEEE1547 IEEE1547 1 CSA C22 2 107 1 01 2001 FCC Part 15 Sub part B Class B Limits CSAUS C 10 years 15 20 years TRIO 20 0 TL OUTD S US 480 TRIO 27 6 TL OUTD S US 480 TRIO 20 0 TL OUTD S1 US 480 TRIO 27 6 TL OUTD S1 US 480 TRIO 20 0 TL OUTD S1A US 480 TRIO 27 6 TL OUTD S1A US 480 TRIO 20 0 TL OUTD S1B US 480 TRIO 27 6 TL OUTD S1B US 480 TRIO 20 0 TL OUTD S US 480 A TRIO 27 6 TL OUTD S US 480 A TRIO 20 0 TL OUTD S1 US 480 A TRIO 27 6 TL OUTD S1 US 480 A TRIO 20 0 TL OUTD S1A US 480 A TRIO 27 6 TL OUTD S1A US 480 A TRIO 20 0 TL OUTD S1B US 480 A TRIO 27 6 TL OUTD S1B US 480 A All data is subject to change without notice Product flyer for TRIO 20 0 27 6 TL OUTD ABB Solar Inverters 3
Block diagram of TRIO-20.0 27.6-TL-OUTD IN1A     IN1A       IN1C     IN1D     IN1D     IN1B -   IN1  IN1A -  IN1B -   -  I...
Perfect Welding Solar Energy Perfect Charging FRONIUS GALVO The future of residential solar has arrived The revolutionary new Fronius Galvo Fast PC board replacement SnapINverter Mounting system AFCI NEC 2014 Ready Wi Fi on board Smart Grid Ready Fronius introduces the brand new Fronius Galvo The Fronius Galvo is the first and only Wi Fi enabled super lightweight residential inverter that disrupts the residential solar market by providing a list of features never before seen in the solar industry With the revolutionary Fronius SnapINverter hinge mounting system which allows for a single person installation in record time it is no wonder that installers are demanding the Fronius Galvo more than any other string inverter currently available The Fronius Galvo provides an extra wide voltage window allowing for utmost flexibility in string design The industry leading Fronius Service Provider program allows full service in less than 15 minutes by one installer with one truck roll System owners are amazed by the attractive new low profile design integrated Wi Fi with included Fronius Solar web monitoring portal and Fronius smart phone app the touch sensitive display and quiet high performance The new Fronius Galvo creates convenience and sets the industry standard in installation service and overall ownership TECHNICAL DATA FRONIUS GALVO INPUT DATA Recommended PV Power kWp Max usable input current GALVO 1 5 1 GALVO 2 0 1 GALVO 2 5 1 GALVO 3 1 1 1 2 2 4 13 4 A 13 4 A 13 4 A 16 7 A 1 6 3 2 17 0 A 17 9 A 17 9 A 22 4 A 2 0 3 8 16 1 A 16 1 A 16 1 A 20 1 A 2 5 4 5 18 7 A 20 0 A 20 0 A 25 0 A 208 V 220 V 240 V Max array short circuit current Nominal input voltage Min Max input voltage DC startup voltage MPP Voltage Range Admissable conductor size DC Number of DC input terminals 260 V 120 V 420 V 140 V 120 V 335 V AWG 14 to AWG 6 CU AWG 6 AL solid 3x DC and 3x DC screw terminals for solid copper or aluminium and stranded fine stranded copper OUTPUT DATA AC nominal output power Max output power Max output current 330 V 165 V 550 V 185 V 165 V 440 V GALVO 1 5 1 208 V 220 V 240 V Admissable conductor size AC Max output overcurrent protection Grid connection Frequency Frequency range Total harmonic distortion Power factor range The term Wi Fi is a registered trademark of the Wi Fi Alliance 1 500 VA 1 500 VA 8 2 A 7 7 A 7 1 A GALVO 2 0 1 GALVO 2 5 1 2 000 VA 2 500 VA 2 000 VA 2 500 VA 9 1 A 13 7 A 9 1 A 12 9 A 9 1 A 11 8 A AWG 14 to AWG 6 CU AWG 6 AL solid 20 A 208 220 and 240 V 60 Hz 45 65 Hz
  Perfect Welding   Solar Energy   Perfect Charging  FRONIUS GALVO   The future of residential solar has arrived - The rev...
FRONIUS GALVO 3 1 1 TEMPERATURE DERATING 98 4 000 OUTPUT POWER W CEC EFFICIENCY FRONIUS GALVO 3 1 1 CEC EFFICIENCY CURVE 96 94 92 3 000 2 000 90 1 000 88 86 0 0 10 20 30 50 75 100 165 VDC 330 VDC 440 VDC OUTPUT POWER 40 60 80 100 120 165 VDC 330 VDC 440 VDC AMBIENT TEMPERATURE F TECHNICAL DATA FRONIUS GALVO GENERAL DATA GALVO 1 5 1 Dimensions height x width x depth Weight Protection Class Night time consumption Inverter technology Cooling Installation Ambient operating temperature range Permitted relative humidity Elevation INTERFACES Wi Fi Ethernet LAN Digital inputs outputs USB A socket 2x RS422 RJ45 socket Datalogger and Webserver RS485 36 93 lbs NEMA 4X
FRONIUS GALVO 3.1-1 TEMPERATURE DERATING  98  4,000  OUTPUT POWER  W   CEC EFFICIENCY      FRONIUS GALVO 3.1-1 CEC EFFICIE...
Perfect Welding Solar Energy Perfect Charging FRONIUS PRIMO The future of residential solar is here Introducing the new Fronius Primo N W E S PC board replacement process SnapINverter mounting system Wi Fi interface SuperFlex Design Smart Grid Ready Arc Fault Circuit Interruption With power categories ranging from 3 8 kW to 8 2 kW the transformerless Fronius Primo is the ideal compact single phase inverter for residential applications The sleek design is equipped with the SnapINverter hinge mounting system which allows for lightweight secure and convenient installation and service The Fronius Primo has several integrated features that set it apart from competitors including dual powerpoint trackers high system voltage a wide input voltage range and unrestricted use indoors and outdoors Other standard features include a Wi Fi and SunSpec Modbus interface for seamless monitoring and datalogging Arc Fault Circuit Interruption AFCI and Fronius s superb online and mobile platform Fronius Solar web The Fronius Primo is NEC 2014 ready and designed to adjust to future standards offering a complete solution to code restrictions and technical innovations of tomorrow TECHNICAL DATA FRONIUS PRIMO GENERAL DATA Dimensions width x height x depth Weight Degree of protection Night time consumption Inverter topology Cooling Installation Ambient operating temperature range Permitted humidity DC connection terminals AC connection terminals Certificates and compliance with standards STANDARD WITH ALL PRIMO MODELS 16 9 x 24 7 x 8 1 in 47 29 lb NEMA 4X
  Perfect Welding   Solar Energy   Perfect Charging  FRONIUS PRIMO   The future of residential solar is here - Introducing...
TECHNICAL DATA FRONIUS PRIMO INPUT DATA PRIMO 3 8 1 PRIMO 5 0 1 3 0 6 0 kW 18 A 18 A 4 0 7 8 kW 18 A 18 A 410 V Recommended PV power kWp Max usable input current MPPT 1 MPPT 2 Operating voltage range Max input voltage 420 V Nominal input voltage Admissable conductor size DC PRIMO 6 0 1 4 8 9 3 kW 18 A 18 A 80 600 V 600 V 420 V PRIMO 7 6 1 PRIMO 8 2 1 6 1 11 7 kW 18 A 18 A 6 6 12 7 kW 18 A 18 A 420 V 420 V AWG 14 AWG 6 MPP Voltage Range Number of MPPT 200 480 V 240 480 V 240 480 V 2 250 480 V 270 480 V PRIMO 3 8 1 PRIMO 5 0 1 PRIMO 6 0 1 PRIMO 7 6 1 PRIMO 8 2 1 Current value 150 V until late March 2015 OUTPUT DATA Max output power 208 3800 W 5000 W 6000 W 7600 W 7900 W Max continuous output current 240 208 3800 W 18 3 A 5000 W 24 0 A 6000 W 28 8 A 7600 W 36 5 A 8200 W 38 0 A 240 15 8 A 20 8 A 25 0 A 31 7 A 34 2 A Recommended OCPD AC breaker size 208 25 A 30 A 40 A 50 A 50 A 240 20 A 30 A 35 A 40 A 45 A 96 7 96 9 96 9 96 9 97 0 95 0 95 5 96 0 96 0 96 5 CEC Efficiency 240 Admissable conductor size AC Grid connection Frequency Total harmonic distortion Power factor cos ac r AWG 14 AWG 6 208 240 60 Hz 5 0 0 85 1 ind cap Perfect Welding Solar Energy Perfect Charging WE HAVE THREE DIVISIONS AND ONE PASSION SHIFTING THE LIMITS OF POSSIBILITY Whether welding technology photovoltaics or battery charging technology our goal is clearly defined to be the innovation leader With around 3 000 employees worldwide we shift the limits of what s possible our record of over 1 000 granted patents is testimony to this While others progress step by step we innovate in leaps and bounds Just as we ve always done The responsible use of our resources forms the basis of our corporate policy Further information about all Fronius products and our global sales partners and representatives can be found at www fronius com Fronius USA LLC 6797 Fronius Drive Portage IN 46368 USA Rev 2 20 15 USA pv support usa fronius com www fronius usa com Text and images correspond to the current state of technology at the time of printing Subject to modifications All information is without guarantee in spite of careful editing liability excluded Copyright 2011 Fronius All rights reserved Max Efficiency
TECHNICAL DATA FRONIUS PRIMO INPUT DATA  PRIMO 3.8-1  PRIMO 5.0-1  3.0 - 6.0 kW 18 A   18 A  4.0 - 7.8 kW 18 A   18 A  410...
Perfect Welding Solar Energy Perfect Charging FRONIUS SYMO The future of commercial solar is here Introducing the new Fronius Symo N W E S PC Board Replacement Process SnapINverter Mounting System Integrated Data Communication SuperFlex Design Smart Grid NEC 2014 Compliant AFCI Integrated Dynamic Peak Manager Featuring nine models ranging from 10 kW to 24 kW the transformerless Fronius Symo is the ideal compact three phase inverter for commercial applications The high system voltage and wide input voltage range ensure maximum flexibility in system design With its low roof loading NEMA 4X and 1000 volt DC rating the Fronius Symo can be mounted in many different ways The modern design is equipped with the SnapINverter mounting system allowing for lightweight secure and convenient installation and repair Several industry leading features come standard with the Fronius Symo including Wi Fi and SunSpec Modbus interfaces for seamless monitoring and datalogging field proven Arc Fault Circuit Interruption AFCI NEC 2014 compliant and Fronius superb online and mobile monitoring platform Fronius Solar web The Fronius Symo the most communicative efficient and streamlined three phase string inverter on the market TECHNICAL DATA FRONIUS SYMO GENERAL DATA Dimensions width x height x depth Degree of protection Night time consumption Inverter topology Cooling Installation Ambient operating temperature range Permitted humidity DC connection terminals AC connection terminals Certificates and compliance with standards GENERAL DATA Weight PROTECTIVE DEVICES AFCI 2014 NEC Ready DC disconnect DC reverse polarity protection Ground Fault Protection with Isolation Monitor Interrupter STANDARD WITH ALL SYMO MODELS 20 1 x 28 5 x 8 9 inches NEMA 4X
  Perfect Welding   Solar Energy   Perfect Charging  FRONIUS SYMO   The future of commercial solar is here - Introducing t...
TECHNICAL DATA FRONIUS SYMO INPUT DATA 10 0 3 208 240 Max usable input current MPPT1 MPPT 2 MPP voltage range Operating voltage range Max input voltage Nominal input voltage 208 220 240 480 10 0 3 480 12 5 3 480 15 0 3 480 17 5 3 480 20 0 3 480 22 7 3 480 24 0 3 480 8 0 13 0 Recommended PV power kWp 12 0 3 208 240 9 5 15 5 8 0 13 0 10 0 16 0 12 0 19 5 14 0 23 0 16 0 26 0 18 0 29 5 19 0 31 0 500 800 V 500 800 V NA NA 720 V NA NA 720 V 300 500 V 200 600 V 600 V 350 V 370 V NA 25 0 A 16 5 A 300 500 V 300 800 V 200 600 V 200 1000 V 600 V 1000 V 350 V NA 370 V NA NA 675 V Admissable conductor size DC 350 800 V 350 800 V NA NA 685 V NA NA 685 V AWG 14 AWG 6 copper direct AWG 6 aluminum direct AWG 4 AWG 2 copper or aluminum with input combiner Number of MPPT 2 OUTPUT DATA 10 0 3 208 240 208 220 240 12 0 3 208 240 10 0 3 480 12 5 3 480 15 0 3 480 17 5 3 480 20 0 3 480 22 7 3 480 24 0 3 480 9995 VA 9995 VA 11995 VA 11995 VA NA NA NA NA NA NA NA NA NA NA NA NA NA NA 480 NA NA 9995 VA 12495 VA 14995 VA 17495 VA 19995 VA 22727 VA 23995 VA 208 Max output current 31 5 A 35 0 A NA NA NA NA NA NA NA 29 7 A 27 3 A 35 0 A 32 8 A NA NA NA NA NA NA NA NA NA 13 7 A 17 1 A 20 5 A 23 9 A 27 4 A 31 1 A 32 8 A NA 220 240 480 Max Efficiency 97 0 97 0 98 1 98 1 208 96 5 96 5 NA NA NA NA NA NA 240 96 5 96 5 NA NA NA NA NA NA NA 480 CEC Efficiency 98 0 NA NA 96 5 97 0 97 0 97 5 97 5 97 5 97 5 208 240 208 240 480 Delta N 480 Delta N Admissable conductor size AC Grid connection Uac r AWG 14 AWG 6 Frequency fr Total harmonic distortion 1 75 Power factor INTERFACES Wi Fi Ethernet Serial 6 inputs and 4 digital I Os USB A socket 2x RS422 RJ45 socket 480 Delta N 60 Hz 0 1 ind cap STANDARD WITH ALL FRONIUS SYMO MODELS Wireless standard 802 11 b g n Fronius Solar web SunSpec Modbus TCP JSON SunSpec Modbus RTU Load management signaling multipurpose I O Datalogging and inverter update possible via USB Fronius Solar Net interface protocol Datalogger and Webserver Included The term Wi Fi is a registered trademark of the Wi Fi Alliance N for sensing purposes no current carrying conductor Fronius USA LLC 6797 Fronius Drive Portage IN 46368 USA pv support usa fronius com www fronius usa com Rev 2 9 15 USA Perfect Welding Solar Energy Perfect Charging WE HAVE THREE DIVISIONS AND ONE PASSION SHIFTING THE LIMITS OF POSSIBILITY Whether welding technology photovoltaics or battery charging technology our goal is clearly defined to be the innovation leader With around 3 000 employees worldwide we shift the limits of what s possible our record of over 1 000 granted patents is testimony to this While others progress step by step we innovate in leaps and bounds Just as we ve always done The responsible use of our resources forms the basis of our corporate policy Further information about all Fronius products and our global sales partners and representatives can be found at www fronius com Text and images correspond to the current state of technology at the time of printing Subject to modifications All information is without guarantee in spite of careful editing liability excluded Copyright 2011 Fronius All rights reserved Max output power 33 0 A 25 0 A 400 800 V 450 800 V 200 1000 V 1000 V NA NA NA NA 695 V 710 V
TECHNICAL DATA FRONIUS SYMO INPUT DATA  10.0-3 208 240  Max. usable input current  MPPT1 MPPT 2  MPP-voltage range Operati...
Solar Sockets 100 Amps 4 Terminals 600 VAC SOLAR FRIENDLY 2 3 2 1 4175 5929 5934 4175 3 4 U5934 XL BLG U6087 XL U4175 RL BLG 100 Amps 4 Terminals Residential Solar Sockets Standard Neutral Catalog Number Socket Type Service Hub U4175 RL BLG Ringless OH UG U6087 XL Ring Type OH UG Connectors CU AL Dimensions Knockouts Line Load D W H 1 2 3 H O 14 1 0 14 1 0 5 3 16 8 11 2 2 1 1 2 1 1 4 1 4 C P 14 1 0 14 1 0 3 16 8 11 2 2 1 2 1 4 1 4 5 1 1 1 1 4 100 Amps 4 Terminals Residential Solar Sockets Integral Isolated Neutral Option Catalog Number Socket Type Service Hub U5929 XL INS Ring Type OH UG U5934 XL BLG Ringless OH UG Connectors CU AL Dimensions Knockouts Line Load D W H 1 2 3 C P 14 1 0 14 1 0 5 3 16 8 11 2 2 1 1 2 1 1 4 1 4 C P 14 1 0 14 1 0 35 16 8 111 2 2 11 2 11 4 1 4 1 4 Notes Application The standard bonded neutral units are applicable in areas where utility does not require an isolated neutral BLG Barrel lock guard knockout provision Hubs Accepts standard meter socket hubs Construction Units are Type 3R for durable outdoor use lockable and sealable Utility requirements for this equipment may vary Always consult the serving utility for their requirements before ordering or installing equipment Milbank Manufacturing 4801 Deramus Ave Kansas City MO 64120 877 483 5314 milbankworks com SOLAR SOCKETS 8 13
Solar Sockets 100 Amps   4 Terminals   600 VAC SOLAR-FRIENDLY  2  3  2  1  4175 5929 5934 4175  3 4  U5934-XL-BLG  U6087-X...
This diagram is an illustration of one photovoltaic labeling scenario The number and type of labels needed will vary based on the project scope and its related specifications Check with AHJ for local requirements 11 NEC Article 110 16 and NFPA 70E Article 130 5 C 1 2 3 Part No 558 00381 INV1 A BLACK B RED C BLUE NEUTRAL WHITE PER NEC 408 4 B Part No 558 00309 SECOND SERVICE DISCONNECT ON NORTH SIDE OF BUILDING NEC 230 2 E NEC 230 72 A l Part No 558 00313 NOTE Electrical Service equipment must be field marked per the NEC Code when it is present in a building or structure other than dwelling units supported by more than one service provider i e public utilities such as electricity and a PV System This includes Arc Flash and informational labeling 1 NEC 210 5 C 1 B Part No 558 00307 THIS PANEL FED FROM INV1 MAX AVAILABLE FAULT CURRENT 46 552 AMPS DATE 2 15 12 Combiner Box Circuits Conduit Combiner Box Enclosures EMT Enclosures NEC Article 690 56 C l Part No 596 00474 Reflective Material Required PER NEC 110 24 A l Part No 558 00313 PER NEC 408 4 B Part No 558 00313 4 EMT Conduit Raceways Reflective Material Required NEC 690 31 G 3 4 l Part No 596 00206 NEC 690 17 E l Part No 596 00497 NEC 690 35 F l Part No 596 00588 2 5 Inverter 6 Production Net Meter Building Structure NEC 110 27 C OSHA 1910 145 f 7 Part No 596 00499 NEC 690 5 C l Part No 596 00498 NEC 690 5 C l Part No 596 00498 7 NEC 690 56 B l Part No 558 00350 3 NEC 690 31 G I l Part No 596 00257 DC Disconnect Breaker Recombiner Box Production Net Meter Bi directional NEC 690 31 I l Part No 596 00590 NEC 690 15 NEC 690 13 B l Part No 558 00613 IFC 605 11 3 NEC 690 15 NEC 690 13 B Part No 596 00238 WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM NEC 690 35 F l Part No 596 00588 NEC 690 54 l Part No 596 00239 8 NEC 705 12 D 3 NEC 690 64 l Part No 596 00495 AC Disconnect Breaker Points of Connection NEC 690 53 l Part No 596 00241 IFC 605 11 3 NEC 690 15 NEC 690 13 B Part No 596 00237 NEC 690 17 E l Part No 596 00496 NEC 690 52 l Part No 596 00252 NEC 690 53 l Part No 596 00253 NEC 690 13 B l Part No 596 00239 FOR MARKING DC BACKUP SYSTEMS l Part No 596 00240 NEC 690 17 E l Part No 596 00497 Requirements for Electrical Installations Field Marking NEC 110 16 Electrical equipment that are in other than dwelling units shall be field marked to warn qualified persons of a potential Arc Flash hazard NEC 110 24 A Service equipment in other than dwelling units shall be legibly field marked with the available fault current 24 NEC 110 27 C Entrances to rooms or other guarded locations that contain exposed live parts shall be marked with conspicuous warning signs forbidding unqualified persons to enter NEC 230 2 E Where a building or structure is supported by more than one service add a plaque to denote all other services www hellermann tyton com 800 537 1512 NEC 210 5 C 1 B Branch Circuits The identification methods used for conductors originating within each branch circuit shall be documented in a manner that is readily available or shall be permanently posted at each branch circuit panelboard or distribution equipment NEC 408 4 B All switchboards and panelboards supplied by a feeder in other than one or two family dwellings shall be marked to indicate the device or equipment where the power supply s originates
                           This diagram is an illustration of one photovoltaic labeling scenario. The number and type of l...
Photovoltaic System LABELING REQUIREMENTS NEC 2014 ARTICLE 690 AND IFC 2012 Where required elsewhere in this code and field applied labels warning s and marking shall comply with ANSI Z535 4 NEC 110 21 B FIELD MARKING Adhesive fastened signs may be acceptable if properly adhered Vinyl signs shall be weather resistant IFC 605 11 1 3 The label shall be suitable for the environment where it is installed NEC 110 21 B 3 9 Breaker Panel Pull Boxes 10 NEC 690 13 B Each photovoltaic system disconnecting means shall be permanently marked to identify it as a photovoltaic system disconnect NEC 690 15 IFC 605 11 3 If the equipment is energized from more than one source the disconnecting means must be grouped and identified NEC 690 16 B Non load break rated disconnect means shall be marked NEC 690 17 E Where all terminals of the disconnecting means may be energized in the open position a warning label shall be mounted on or adjacent to the disconnecting means Adhesive Fastened Signs ANSI Z535 4 2011 Product safety signs and labels provides guidelines for the design and durability of safety signs and labels for application to electrical equipment NEC 110 21 B 1 Labeling Requirements for Article 690 Main Service Disconnect NEC 690 31 B Identification and Grouping Photovoltaic system conductors shall be identified and grouped The means of identification shall be permitted by separate color coding marking tape tagging or other approved means NEC 690 31 G 3 4 IFC 605 11 1 2 Labels shall appear at every section of the wiring system that is separated by enclosures walls partitions ceilings or floors Spacing between labels not to exceed 10 feet 3M NEC 690 33 E 2 Interruption current be a type that requires the use of a tool to open will be marked Do Not Disconnect Under Load NEC 690 35 F A PV power source shall be labeled at each junction box combiner box or disconnect and device where energized ungrounded circuits may be exposed during service NEC 690 31 G 1 Where circuits are embedded in build up laminate or membrane roofing materials not covered by PV modules and associated equipment the location of the circuits shall be clearly marked NEC 690 5 C l Part No 596 00498 NEC 690 17 E l Part No 596 00497 NEC 690 35 F l Part No 596 00588 NEC 690 10 C l Part No 596 00591 NEC 690 17 E l Part No 596 00497 NEC 690 5 C l Part No 596 00499 NEC 690 15 NEC 690 13 B l Part No 596 00243 NEC 690 54 l Part No 596 00239 WARNING DUAL POWER SOURCE NEC 690 15 NEC 690 13 B l Part No 558 00613 SECOND SOURCE IS PHOTOVOLTAIC SYSTEM NEC 705 12 D 3 NEC 690 64 l Part No 596 00495 11 Main Service Disconnect NEC 705 12 D 3 B l Part No 596 00589 NEC 705 15 D 3 NEC 690 64 Part No 596 00587 NEC 705 12 D 3 B In systems with panel boards connected in a series the rating of the first overcurrent device directly connected to the output of the utility interactive inverter s shall be used in calculations for all busbars and conductors A permanent label shall be applied to the distribution equipment with the following or equivalent wording NEC 690 15 NEC 690 13 B l Part No 596 00243 NEC 705 12 D 3 Equipment containing overcurrent devices in circuits supplying power to a busbar or conductor supplied from multiple sources shall be marked to indicate the presence of all sources NEC 690 5 C A label shall appear on the utility interactive inverter or be applied by the installer near the ground fault indicator at a visible location NEC 690 52 AC modules shall be marked with identification terminals or leads with the ratings as shown on the label NEC 690 33 E 2 l Part No 596 00244 NEC 110 27 C OSHA 1910 145 f 7 Part No 596 00499 NEC 690 31 I Bipolar photovoltaic systems shall be clearly marked with a permanent legible warning notice indicating that the disconnection of the grounded conductor s may result in overvoltage on the equipment NFPA 2012 130 5 C Same as NEC110 16 but includes additional label information that is required after 9 30 2011 Check latest 2012 NFPA Arc Flash requirements OSHA 1910 145 F 7 Warning tags are used to represent a hazard level between Caution and Danger NEC 690 53 A permanent label for the direct current PV power source shall be provided by the installer at the PV disconnecting means NEC 690 54 All interactive system points of interconnection with other sources shall be marked at an accessible location at the disconnecting means as the power source and with the rated AC output current and the nominal operating AC voltage NEC 690 55 PV power systems employing energy storage shall also be marked with the maximum operating voltage including any equalization voltage and polarity of the grounded circuit conductor NEC 690 56 C Each Rapid Shutdown Switch shall be permanently marked to identify it as a Photovoltaic Rapid Shutdown The sign or placard shall be marked as PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN using white letters that are 3 8 tall on a red background and shall be reflective NEC 690 64 Points of connection shall be in accordance with NEC 705 12 25
Photovoltaic System  LABELING REQUIREMENTS NEC 2014 ARTICLE 690 AND IFC 2012  Where required elsewhere in this code and fi...
Solar Energy Solutions Pre printed Solar Labels NEC 2014 Labels HellermannTyton pre printed solar installation labels have a special adhesive for use on both enamel and powder coat paint surfaces Labels are printed with UV stable ink that is covered by a UV stable laminate Labels meet the requirements of UL969 NEC 2014 labels can be used to meet NEC 2014 code and are backward compatible to NEC 2011 WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM 596 00495 Material Data 596 00587 Material 596 00496 596 00589 443 552 UV Stable Flexible White Vinyl w Acrylic Laminate Operating Temperature 40 F 40 C to 175 F 79 C Min Application Temp 50 F 10 C Liner Certifications 596 00499 78 White Bleached Paper UL969 596 00588 596 00498 596 00497 596 00590 596 00591 Product Selection Article No Part No Type 596 00497 596 00497 WESHLBL 596 00496 596 00496 WESHLBLDC 596 00498 596 00498 WGCME 596 00588 596 00588 WDCCU 596 00499 596 00499 WTOPVLBL 596 00495 596 00495 WDPSLBL 596 00587 596 00587 CBACKFED Width in mm Height in mm Pkg Qty Per Roll WARNING ELECTRICAL SHOCK HAZARD 3 75 95 25 2 0 50 8 50 RL WARNING ELECTRICAL SHOCK HAZARD W DC 3 75 95 25 2 5 63 5 50 RL WARNING GROUNDED CONDUCTORS MAY BE ENERGIZED 4 12 104 6 2 50 8 50 RL Description Pkg Type WARNING DC CONDUCTORS MAY BE ENERGIZED 4 12 104 6 2 50 8 50 RL WARNING TURN OFF PV AC PRIOR TO WORKING INSIDE PANEL 4 12 104 6 2 50 8 50 RL WARNING DUAL POWER SOURCE 4 12 104 6 75 19 05 50 RL CAUTION PHOTOVOLTAIC SYSTEM CIRCUIT BREAKER IS BACKFED 4 12 104 6 75 19 05 50 RL 596 00590 596 00590 BIPOLARPV WARNING BIPOLAR PHOTOVOLTAIC ARRAY 3 75 95 25 2 0 50 8 50 RL 596 00589 596 00589 IOCOD WARNING INVERTER OUTPUT CONNECTION 4 12 104 6 75 19 05 50 RL 596 00591 596 00591 120VOLT WARNING 120 VOLT SUPPLY 3 75 95 25 2 0 50 8 50 RL Use Part No for ordering and Type for specification 27
Solar Energy Solutions  Pre-printed Solar Labels  NEC 2014 Labels HellermannTyton pre-printed solar installation labels ha...
Pre printed Solar Labels NEC 2011 Labels HellermannTyton pre printed solar installation labels have a special adhesive for use on both enamel and powder coat paint surfaces Labels are printed with UV stable ink that is covered by a UV stable laminate Labels meet the requirements of UL969 NEC 2011 labels can be used to meet the NEC 2011 code and are backward compatible to NEC 2008 Material Data Material 443 552 UV Stable Flexible White Vinyl w Acrylic Laminate Operating Temperature 40 F 40 C to 175 F 79 C Min Application Temp 50 F 10 C Liner Certifications 78 White Bleached Paper UL969 596 00234 596 00233 596 00258 596 00232 596 00231 596 00236 596 00235 Product Selection Article No Part No 596 00233 WESHLBL 596 00232 596 00232 WESHLBLDC 596 00234 596 00234 WGCME 596 00258 596 00258 WDCCU 596 00235 596 00235 WTOPVLBL 596 00231 596 00231 WDPSLBL 596 00236 596 00236 CBACKFED Height in mm 3 75 95 25 2 0 50 8 50 WARNING ELECTRICAL SHOCK HAZARD W DC 3 75 95 25 2 5 63 5 50 RL WARNING GROUNDED CONDUCTORS MAY BE ENERGIZED 4 12 104 6 2 50 8 50 RL WARNING DC CONDUCTORS MAY BE ENERGIZED 4 12 104 6 2 50 8 50 RL Type 596 00233 Width in mm Pkg Qty Per Roll Description WARNING ELECTRICAL SHOCK HAZARD RL WARNING TURN OFF PV AC PRIOR TO WORKING INSIDE PANEL 4 12 104 6 2 50 8 50 RL WARNING DUAL POWER SOURCE 4 12 104 6 75 19 05 50 RL CAUTION PV SYSTEM CIRCUIT BREAKER IS BACKFED 4 12 104 6 75 19 05 50 RL Use Part No for ordering and Type for specification 28 Pkg Type www hellermann tyton com 800 537 1512
Pre-printed Solar Labels  NEC 2011 Labels HellermannTyton pre-printed solar installation labels have a special adhesive fo...
Solar Energy Solutions Pre printed Solar Labels Reflective Solar Labels Reflective Solar Labels are designed to be easy to see by first responders who are looking to identify and isolate the PV system Reflective labels can be seen through smoke and in darkness using reflected light HellermannTyton preprinted Reflective Solar Labels meet fire safety and NEC regulations 596 00244 596 00206 596 00246 596 00474 Material Data Material 242 552 UV Stable Reflective Vinyl w Acrylic Laminate Operating Temperature 596 00255 40 F 40 C to 175 F 79 C Min Application Temp 596 00243 50 F 10 C Liner 596 00613 596 00615 Certifications Polyethylene Coated Paper UL969 Product Selection Article No Part No 596 00244 DNDCUL 596 00613 596 00613 CSESC Height in mm DO NOT DISCONNECT UNDER LOAD 6 5 165 1 1 25 4 50 RL CAUTION SOLAR ELECTRIC SYSTEM CONNECTED 6 5 165 1 1 25 4 50 RL Type 596 00244 Width in mm Pkg Qty Per Roll Description Pkg Type 596 00615 596 00615 CSCIRLBL CAUTION SOLAR CIRCUIT 6 5 165 1 1 25 4 50 RL 596 00246 596 00246 SOLARD SOLAR DISCONNECT 6 5 165 1 1 25 4 50 RL 596 00243 596 00243 MPVSD MAIN PHOTOVOLTAIC SYSTEM DISCONNECT 5 5 139 7 1 75 44 45 50 RL 596 00255 596 00255 MPVACDIS MAIN PHOTOVOLTAIC SYSTEM AC DISCONNECT 5 5 139 7 1 75 44 45 50 RL 596 00474 596 00474 PSEWRS PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN 5 5 139 7 1 75 44 45 50 RL 596 00206 596 00206 PVPSR WARNING PHOTOVOLTAIC POWER SOURCE 6 5 165 1 1 25 4 50 RL Use Part No for ordering and Type for specification HellermannTyton makes it easy to pass inspection In addition to our full line of pre printed NEC 2014 and NEC 2011 labels TagPrint Pro 3 0 TagPrint Xpress Solar and the Sport handheld printer include label templates to meet NEC 2014 and NEC 2011 29
Solar Energy Solutions  Pre-printed Solar Labels  Reflective Solar Labels Reflective Solar Labels are designed to be easy ...
Printable Solar Labels Printable Solar Labels Designed with cross laminated UV stable materials these variable printable solar installation labels are designed to accept printing from any standard thermal transfer printer using a resin based ink ribbon for the best durability Print your voltage information directly on the label and then laminate with an optional clear polyester laminate material for added protection These labels can be used to print disconnecting means and breaker series directly on the labels for a more professional result and a smoother inspection process Material Data Material 840 926 UV Stable White Polyester w Clear Polyester Laminate Operating Temperature 40 F 40 C to 300 F 150 C Min Application Temp 50 F 10 C Liner 55 Paper Certifications UL969 TT230SMC 596 00239 596 00253 596 00240 596 00237 596 00238 596 00241 596 00242 596 00252 Product Selection Width in mm Height in mm Pkg Qty Per Roll Pkg Type DC MODULE LABEL 4 101 6 2 50 8 50 RL ACRATING DC BACKUP SYSTEM LABEL 4 101 6 2 50 8 50 RL 596 00241 DCRATING DC RATING LABEL 3 75 95 25 2 50 8 50 RL 596 00239 PVACDIS PV AC DISCONNECT RATING 3 75 95 25 1 25 4 50 RL 596 00237 596 00237 ACDISCT PHOTOVOLTAIC AC DISCONNECT 3 75 95 25 1 25 4 50 RL 596 00238 596 00238 DCDISCT PHOTOVOLTAIC DC DISCONNECT 3 75 95 25 1 25 4 50 RL 596 00242 596 00242 LAM1 LAMINATE FOR AC DC RATING LABEL 4 2 106 6 2 25 57 15 50 RL 596 00252 596 00252 AC2011 4 101 6 2 50 8 50 RL Article No Part No Type 596 00253 596 00253 DC2011 596 00240 596 00240 596 00241 596 00239 Description AC MODULE LABEL Use Part No for ordering and Type for specification If using a TT130SMC printer select label widths up to 2 50 8 mm All other HellermannTyton thermal transfer printers will work with label widths up to 4 wide 101 6 mm For a listing of Printable Solar Labels designed to fit the TT130SMC see page 41 32 www hellermann tyton com 800 537 1512
Printable Solar Labels  Printable Solar Labels Designed with cross-laminated UV stable materials, these variable printable...
Plugs and Sockets ACCESSORIES Multi Contact MC3 and MC4 connector systems Multi Contact AG was founded in 1962 and is currently employing more than 700 staff All manufacturing sites are ISO 9001 certi ed and therefore meet the highest quality demands n n n n n MC connector systems The components of the MC connector system for photovoltaics are designed to allow time saving and safe serial and parallel wiring of PV modules for buildingintegrated and free standing solar installations For practical use the connector systems MC3 and MC4 are available depending on the existing modules or inverters The interlockable MC4 connector systems n n n n n n n The proven MC3 connector systems n n n n Diameter 3 mm Rated current max 30 A for 6 mm max 20 A for 4 mm The MC3 plugs and sockets shown with associated contacts System voltage max 1000 V Degree of protection connected IP65 Protection class II Temperature range 40 C to 90 C T V Rheinland type approved Diameter 4 mm Rated current max 30 A System voltage max 1000 V Degree of protection connected IP67 Easy installation Locking system Snap in Protection class II Temperature range 40 C to 90 C T V Rheinland type approved The MC4 plugs and sockets shown with associated contacts
.............................................................................................................................
ACCESSORIES Plugs and Sockets Art No 1302000 1302010 1302050 1302040 1302020 Model Warranty MultiContact PV KBT3II A 2 4 mm D 4 9 7 1 mm Female type MC3 for Radox Draka Studer 4 mm 2 years MultiContact PV KST3II A 2 4 mm D 4 9 7 1 mm Male type MC3 for Radox Draka Studer 4 mm 2 years MultiContact PVKBT3 6III A 6 mm D 6 5 9 mm Female type MC3 for Radox Draka Studer 6 mm 2 years MultiContact PVKST3 6III A 6 mm D 6 5 9 mm Male type MC3 for Radox Draka Studer 6 mm 2 years MultiContact PVKBT4 6II A 4 6 mm D 5 5 9 mm Female type MC4 for Radox Draka Studer 4 6 mm 2 years Art No 1302030 1302073 1302085 1302086 1302087 Model MultiContact PV R WZ3 MultiContact PV ESCZM 19100 crimping pliers insert Installation device for For MC4 only use with male and female MC3 locator MultiContact PV CZM16100A crimping pliers MultiContact PV LOC crimping pliers locator For MC3 MC4 insert and locator necessary For MC4 only use with crimping pliers insert Warranty MultiContact PVKST4 6II A 4 6 mm D 5 5 9 mm Male type MC4 for Radox Draka Studer 4 6 mm 2 years 2 years 2 years 2 years Art No 1302116 Model Description Description Description 2 years 1302118 1302115 MultiContact PV WZ AD GWD MultiContact PV SSE AD4 MultiContact PV PST test pin Socket wrench insert for crimping pliers PV CZM 2 years For MC type 4 Warranty Socket wrench insert for crimping pliers PV CZM 2 years MultiContact assembly key PVMS For MC type 4 2 years 2 years Art No 1302152 1302153 1302154 1302155 Model MultiContact PV branch plug MC3 PV AZS3 UR For MC type 3 2 years MultiContact PV branch socket MC3 PV AZB3 UR For MC type 3 2 years MultiContact PV branch plug MC4 PV AZS4 For MC type 4 2 years MultiContact PV branch socket MC4 PV AZB4 For MC type 4 2 years Description Warranty 1302117 The MC3 plugs are based on contacts with a diameter of 3 mm and comply with protection class IP65 The interlockable MC4 plugs have contacts with diameters of 4 mm and comply with protection class IP67 TRITEC Group www tritec energy com 20130311 1 The content of this datasheet is subject to change without prior notice
.............................................................................................................................